Dynamic System Analysis Installation and User's Guide
|
|
|
- Kristina Sims
- 10 years ago
- Views:
Transcription
1 IBM Systems Dynamic System Analysis Installation and User's Guide Version 3.1
2
3 IBM Systems Dynamic System Analysis Installation and User's Guide Version 3.1
4 Note Before using this information and the product it supports, read the information in Notices on page 41. This edition applies to ersion 3.1 of Dynamic System Analysis and to all subsequent releases and modifications until otherwise indicated in new editions. Copyright IBM Corporation 2009, US Goernment Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
5 Contents About this publication Conentions and terminology Publications and related information Web resources i How to send your comments i What's new ix Chapter 1. Technical oeriew Chapter 2. Installing Dynamic System Analysis Hardware and software requirements Hardware requirements Supported hardware Software requirements Supported operating systems Installing Dynamic System Analysis on remoable media Updating system support Chapter 3. Running diagnostic tests on the local system Chapter 4. Collecting system information Collecting system information on the local system using Preboot Edition Collecting system information on the local system 14 Collecting system information on a WinPE image.. 14 Collecting system information on a remote system running the VMware ESXi Collecting IPMI eent logs from a remote system.. 15 Conerting collected data to another format Chapter 5. Comparing system information Comparing installed and latest ersions of firmware 17 Comparing current system information to preiously collected data Comparing multiple system information files Chapter 6. Viewing collected system information Chapter 7. Transferring data and logs 21 Transferring collected data to a remote system Transferring collected data to the IBM customer inentory repository Chapter 8. Troubleshooting and support Known limitations, problems, and workarounds.. 23 Dynamic System Analysis eent log Dynamic System Analysis core dump file Getting help and technical assistance Before you call Using the documentation Getting help and information from the World Wide Web Software serice and support Hardware serice and support Appendix A. Accessibility features for Dynamic System Analysis Appendix B. Dynamic System Analysis commands How to read syntax diagrams DSA command Appendix C. Enironment ariables.. 39 Notices Index Copyright IBM Corp. 2009, 2010 iii
6 i Installation and User's Guide
7 About this publication Conentions and terminology This publication proides information about how to download and use Dynamic System Analysis, including In this book, when you are instructed to enter a command, type the command and press Enter. These notices are designed to highlight key information: Note: These notices proide important tips, guidance, or adice. Important: These notices proide information or adice that might help you aoid inconenient or difficult situations. Attention: These notices indicate possible damage to programs, deices, or data. An attention notice appears before the instruction or situation in which damage can occur. Publications and related information You can iew the same content in the Dynamic System Analysis topic collection in the IBM ToolsCenter for System x and BladeCenter information center as a PDF document. To iew a PDF file, you need Adobe Acrobat Reader, which can be downloaded for free from the Adobe Web site at acrobat/readstep.html.. Information centers and topic collections IBM ToolsCenter for System x and BladeCenter information center publib.boulder.ibm.com/infocenter/toolsctr/1r0/index.jsp View the IBM ToolsCenter for System x and BladeCenter information center which proides integrated information for multiple IBM Systems x and BladeCenter tools, including Dynamic System Analysis. Dynamic System Analysis publib.boulder.ibm.com/infocenter/toolsctr/1r0/topic/dsa/dsa_main.html The Dynamic System Analysis topic collection proides information about how to download and use Dynamic System Analysis to collect, analyze, and diagnose system health, inentory and other information. This information is updated periodically and contains the most up-to-date documentation aailable for Dynamic System Analysis. Publications Installation and User's Guide This publication proides information about how to download and use Dynamic System Analysis to collect, analyze, and diagnose system health, inentory and other information. Copyright IBM Corp. 2009, 2010
8 Web resources How to send your comments Listed here are the Web sites and information center topics that relate to Dynamic System Analysis. Web sites IBM ToolsCenter for System x and BladeCenter CENTER&brandind= View this Web site to download tools that support IBM System x and IBM BladeCenter products. Dynamic System Analysis DSA&brandind= View this Web site to download the Dynamic System Analysis tool and documentation. Support for IBM BladeCenter www-304.ibm.com/systems/support/supportsite.wss/ brandmain?brandind= View this Web site to find information about online technical support, downloads and driers, and RETAIN tips, and to proide feedback about IBM BladeCenter products. Support for IBM System x www-304.ibm.com/jct01004c/systems/support/supportsite.wss/ brandmain?brandind= View this Web site to find information about online technical support, downloads and driers, and RETAIN tips, and to proide feedback about IBM System x products. IBM SererProen View this Web site to learn about hardware compatibility of IBM System x and IBM BladeCenter systems with IBM applications and middleware. Forums IBM System x Forum View this Web site on ibm.com to learn about arious forums that are aailable to discuss technology-related and product-related issues pertaining to IBM Systems hardware and software products. This Web site includes a link for obtaining the forum using a Rich Site Summary (RSS) feed. Your feedback is important in helping to proide the most accurate and highest quality information. If you hae any comments about this publication or any other IBM ToolsCenter for System x and BladeCenter publication, i Installation and User's Guide
9 Go to the IBM ToolsCenter for System x and BladeCenter information center information center Web site at publib.boulder.ibm.com/infocenter/toolsctr/1r0/ index.jsp. There you will find the feedback page where you can enter and submit comments. Complete one of the forms at the back of any IBM ToolsCenter for System x and BladeCenter publication and return it by mail, by fax, or by giing it to an IBM representatie. About this publication ii
10 iii Installation and User's Guide
11 What's new Dynamic System Analysis 3.1 proides additional systems support. New hardware support Dynamic System Analysis supports seeral new systems, LSI RAID controllers, Fibre Channel adapters, Ethernet adapters, and tape dries. For a complete list of supported hardware, see Supported hardware on page 4 Copyright IBM Corp. 2009, 2010 ix
12 x Installation and User's Guide
13 Chapter 1. Technical oeriew Dynamic System Analysis (DSA) is a system information collection and analysis tool that is used by IBM System x Serice and Support personnel to aid in the diagnosis of system problems. This software can be used while the operating system is running. Two editions of Dynamic Systems Analysis are aailable: Preboot Edition You can either create a bootable media such as CD, DVD, ISO, USB or PXE by IBM ToolsCenter Bootable Media Creator(BoMC), See details in the Installation and User's Guide, or download the Windows/Linux update package for Preboot DSA to flash an embedded Preboot image. Then you can reboot the system from the image you created or enter the boot menu to enter Preboot DSA. Portable Edition You can downloaded the Portable Edition from the IBM Web site and install it on remoable media, such as CD, DVD, or USB flash drie, instead of the local system. This edition of Dynamic System Analysis runs from a command line interface as a self-extracting executable file. It creates a temporary directory called /tmp on Linux or %TEMP% on Windows, and extracts all of the Dynamic System Analysis files to that directory. It then runs the command. When the command completes, the temporary directory and all of the Dynamic System Analysis files are deleted from the local system. Dynamic System Analysis collects information about the following aspects of a system, if applicable: System configuration Installed packages Kernel Modules Network interfaces and settings Performance data and details for running processes Hardware inentory, including PCI and USB information IBM LightPath status Serice Processor status and configuration Vital product data, firmware, and basic input/output system (BIOS) information Drie Health Information SereRAID configuration LSI RAID and controller configuration Eent logs for the operating system, SereRAID controllers, and serice processors The system information is collected into a compressed XML file that can be sent to IBM Serice and Support. You can iew the system information using optionally generated HTML Web pages or text files. You can use Dynamic System Analysis to create a merged log that includes eents from all collected logs and to compare the firmware configurations on a serer to those from UpdateXpress. Copyright IBM Corp. 2009,
14 Important: To install or use Dynamic System Analysis, you must be logged in to the local system using a user ID that has administrator or root priileges. On a Linux system, you must log in using the root user name and priilege. On Linux systems, you must run Dynamic System Analysis from a journaling file system (such as ext3 or ReiserFS). You cannot run these commands from a irtual machine file system (VMFS). 2 Installation and User's Guide
15 Chapter 2. Installing Dynamic System Analysis This section proides information about hardware and software requirements, downloading instructions, and updating procedures. Hardware and software requirements Dynamic System Analysis has specific requirements for hardware and software. These requirements include support for a certain supported operating systems and hardware requirements for running Dynamic System Analysis. Hardware requirements To successfully run Dynamic System Analysis, the system on which you install Dynamic System Analysis must meet certain hardware requirements. Disk space requirements To install Dynamic System Analysis, the system must hae 30-MB of disk space. Memory requirements To run Dynamic System Analysis, the system must hae 256-MB or more physical memory for systems running Window and 512-MB or more physical memory systems running Linux. The amount of memory required for this process depends on the size of the logs being collected from the system. It is recommended that DSA Preboot Edition run on a system with more than 1-GB physical memory. To display the DSA data, systems must hae 30-MB to 100-MB of aailable memory. The amount of memory required depends on the size of the logs being iewed. SereRAID requirements Dynamic System Analysis can collect SereRAID log information from SereRAID Manager 6.10 and later. Dynamic System Analysis cannot collect information from the following SereRAID controllers unless SereRAID Manager is installed: SereRAID-7t SATA RAID SereRAID-8i SereRAID-8k SereRAID-8k-l SereRAID-8s Serice processor requirements Enironmental data is aailable only on System x serers that hae either an Integrated System Management Processor (ISMP), a Remote Superisor Adapter (RSA) series serice processor, or an Integrated Management Module (IMM). Copyright IBM Corp. 2009,
16 Supported hardware Use this information to identify arious IBM systems and storage products that are supported by Dynamic System Analysis. Supported Intel and AMD processor-based systems You can run diagnostic tests and collect system information for the following Intel and AMD processor-based systems using Dynamic System Analysis: System x serers IBM System x206m, machine type 8485, 8490 IBM System x236, machine type 8841 IBM System x260 and x3800, machine type 8865, 8866 IBM System x306m, machine type 8849,8491,1887 IBM System x336, machine type 1879,8837 IBM System x346, machine type 8840, 1880 IBM System x366 and x3850, machine type 8863, 8864,7362,7365 IBM System x460 and x3950, machine type 8872, 8878,7363,7366 IBM System x3200, machine type 4362,4363 IBM System x3200 M2, machine type 4367,4368 IBM System x3200 M3, machine type 7237, 7238 IBM System x3250, machine type 4364,4365,4366 IBM System x3250 M2, machine type 4190, 4191, 4194 IBM System x3250 M3, machine type 4251, 4252, 4261 IBM System x3350, machine type 4192, 4193 IBM System x3400 and x3500, machine type 7973,7974, 7975, 7976,7977 IBM System x3400 M2, machine type 7836, 7837 IBM System x3400 M3, machine type 7378, 7379 IBM System x3455, machine type 7940, 7984, 4197, 7941, 7986 IBM System x3500 M2 machine type 7839 IBM System x3500 M3, machine type 7380 IBM System x3550, machine type 7978, 1913 IBM System x3550 M2, machine type 4198, 7946 IBM System x3550 M3, machine type 4254, 7944 IBM System x3620 M3, machine type 7376 IBM System x3650, machine type 7979, 1914 IBM System x3650 M2, machine type 4199, 7947 IBM System x3650 M3, machine type 4255, 7945 IBM System x3690 X5, machine type 7148, 7149 IBM System x3655, machine type 7985,7943 IBM System x3750 M5, machine type 7148, 7149 IBM System x3755, machine type 8877, 7163 IBM System x3850 M2 single node, machine type 7141,7144,7233,7234 IBM System x3850 M3, machine type 7145 IBM System x3950 M2 single node, machine type 7141,7233 IBM System x3950 M2 dual node, machine type 7141,7233 IBM System x3950 M2 3-4 node, machine type 7141,7233 IBM System x3950 X5, machine type 7146 idataplex dx360 M2, machine type 6380, 7321,7322 idataplex dx360 M3, machine type 6391 Lotus Foundations serer, machine type 9234 IBM Smart Business serer, machine type 9233 Intellistation workstations Z40, machine type 9228 Blade serers BladeCenter HS12 blade serer, machine type 1916, 8014, Installation and User's Guide
17 BladeCenter HS20 blade serer, machine type 1883, 8843 BladeCenter HS21 blade serer, machine type 1885, 7995, 8853 BladeCenter HS21 XM blade serer, machine type 1915 BladeCenter HS22 blade serer, machine type 1936, 7809, 7870 BladeCenter HS22V, machine type 7871 BladeCenter HX5, machine type 1909, 7872 AMD Opteron LS20 for IBM BladeCenter, machine type 8850 AMD Opteron LS21 for IBM BladeCenter, machine type 7971 AMD Opteron LS22 for IBM BladeCenter, machine type 7901 AMD Opteron LS41 for IBM BladeCenter, machine type 7972 AMD Opteron LS42 for IBM BladeCenter, machine type 7902 DataPower Integration Blade X150B, machine type 4195 Supported Storage DSA does not run directly on an external storage deice. DSA collects system information and runs diagnostic tests on the following storage deices: IBM System Storage DS3000 IBM System Storage DS4000 IBM System Storage DS8000 Supported Serer Options Host bus adapters Emulex 4Gb/s FC PCI Express HBA (lpe11000/lpe11002) Emulex 4Gb/s FC PCI-X 2.0 HBA (lp11000/lp11002) Emulex 8Gb FC Single-port HBA for IBM System x Emulex 8Gb FC Dual-port HBA for IBM System x IBM SAS HBA controller LSI 1068 SAS HBA QLogic 4G and 8G FC single port HBA QLogic 4G and 8G FC dual port HBA QLogic iscsi PCIe HBA QLogic iscsi PCIe dual port HBA Ethernet adapter Broadcom 10Gb Ethernet CFFh Expansion Card for IBM BladeCenter Broadcom Netextreme II IBM NetXtreme II 1000 Express Ethernet Adapter Fibre Channel adapter Emulex 4G FC exp. card Emulex 4G SFF FC exp. QLogic 4G/8G FC CFF exp. card QLogic 4G/8G FC HBA QLogic 4G/8G SFF FC exp. card Network adapter IBM 10 GbE PCIe SR Serer Adapter IBM NetXtreme II 10 GigE Express Fiber SR Adapter Intel PRO/1000 PT Dual Port Serer Adapter (no diagnostic support) Intel PRO/1000 PT Quad Port Serer Adapter (no diagnostic support) Intel PRO/1000 PF Serer Adapter (no diagnostic support) Chapter 2. Installing Dynamic System Analysis 5
18 RAID adapter Adaptec IBM SereRAID 6i + Adaptec IBM SereRAID 7k and 7t Adaptec IBM SereRAID 8i, 8k,, 8k-l, and 8s LSI AR 10is LSI IR 1078, 1064, and 1064e LSI MegaRAID 1078 LSI MegaRAID 8480 LSI xraid 10i LSI xraid 10k and xraid 10m LSI RAID 0//10 FDE SAS-2 6GB LSI RAID 5 LSI SereRAID MR 10M Tape drie IBM DDS5 tape drie IBM DDS5 SATA 36 and 72 IBM DDS6 tape drie IBM HHLTO4 SAS tape drie IBM LTO2 tape drie IBM LTO2 FH 200 and 400 IBM LTO3 SAS tape drie IBM LTO3 HH SAS 400 and 800 IBM VS160 tape drie IBM GoVault tape drie Daughter card ckvm Daughter Card for IBM BladeCenter LSI BR10ie Software requirements Use this information to understand the required software and supported Web browsers for Dynamic System Analysis. Required deice driers It is strongly recommended that the appropriate serice processor deice driers are installed and running before running Dynamic System Analysis. This proides access to additional problem determination information, including the hardware eent logs. For systems equipped with a Baseboard Management Controller (BMC), the appropriate driers are the IPMI deice drier and mapping layer. If the machine has a Remote Superisor Adapter II (RSA II), use the Remote Superisor Adapter Daemon. For all supported serice processors including the older Remote Superisor Adapter (RSA) or Integrated Systems Management Processor, you can download driers from the Support for IBM System x page on the Web at www-304.ibm.com/jct01004c/systems/support/supportsite.wss/ brandmain?brandind= To collect SCSI & USB deice information (including diagnostics), the "sg" drier must be loaded. Run lsmod and erify that "sg" is loaded before running Dynamic System Analysis. If it is not loaded, run modprobe sg. 6 Installation and User's Guide
19 To collect Broadcom Ethernet firmware leels, the Broadcom NetXtreme Gigabit Ethernet Driers must be installed. The tg3 drier proided by default in current Linux distributions does not export this information. These driers are aailable for download from IBM Support Web site at To collect LSI Logic 1020/1030 SCSI Controller and RAID information, the "mptctl" drier must be loaded. Run lsmod and erify that "mptctl" is loaded before running Dynamic System Analysis. If it is not loaded, run modprobe mptctl. To collect Emulex HBA information, the emulex drier and utility (corekit) must be installed. Run lsmodand erify that "lpfc" and "lpfcdfc" are loaded before running Dynamic System Analysis. To collect Serice Processor logs, configuration, and enironmental data, the appropriate Serice Processor drier must be installed. These driers are aailable for download from IBM Support Web site at (Linux only) To collect SereRAID information for SereRAID controller 7t,8i,8k-l,8k,8s on systems running RedHat 5, libstdc++.so.5 must be installed. To collect Emulex FC HBA data, the Emulex utility (HBAcmd) must be installed. To transfer data collections to the IBM Support site using FTP, libcurl must be installed. To use the UpdateXpress comparison analysis feature, the system on which the analysis is performed must hae an Internet connection. UpdateXpress ersions 4.02 and later are supported. Supported Network Virtual Teaming software Dynamic System Analysis is supported for use with the following Network Virtual Teaming software: Linux Bonding ersions 2.4.1, 2.6.0, & Supported Web browsers To iew the information that is collected by DSA, you must use one of these Web browsers. Internet Explorer 6.0 Serice Pack 1 or later Mozilla or later Firefox 1.04 or later Supported operating systems Use this information to identify operating systems that are supported by Dynamic System Analysis The following operating systems are supported by Dynamic System Analysis. Windows Serer 2008 Editions Microsoft Windows Serer 2008 R2 Microsoft Windows Serer 2008, Datacenter Edition (x86, x64) Microsoft Windows Serer 2008, Web Edition (x86, x64) Microsoft Windows Serer 2008, Enterprise Edition (x86, x64) Chapter 2. Installing Dynamic System Analysis 7
20 Microsoft Windows Serer 2008, Standard Edition (x86, x64) Microsoft Windows Serer 2008 HPC Edition Microsoft Windows Serer 2008 Foundation Windows Essential Business Serer 2008 Premium Edition Windows Essential Business Serer 2008 Standard Edition Windows Serer 2003 Editions Microsoft Windows Serer 2003/2003 R2, Standard Edition (x86, x64) Microsoft Windows Serer 2003/2003 R2, Web Edition Microsoft Windows Serer 2003/2003 R2, Enterprise Edition (x86, x64) Microsoft Windows Serer 2003/2003 R2, Enterprise Edition with Microsoft Cluster Serice (MSCS) Microsoft Windows Serer 2003/2003 R2, Datacenter Edition (x86, x64) Windows Preinstallation Enironment 2.1 and 2.2 SUSE Linux SUSE Linux Enterprise Serer 11 with Xen for AMD64/EM64T SUSE LINUX Enterprise Serer 11 for AMD64/EM64T SUSE LINUX Enterprise Serer 11 for x86 SUSE LINUX Enterprise Real Time 10 AMD64/EM64T SUSE LINUX Enterprise Serer 10 with Xen for AMD64/EM64T SUSE LINUX Enterprise Serer 10 for AMD64/EM64T SUSE LINUX Enterprise Serer 10 with Xen for x86 SUSE LINUX Enterprise Serer 10 for x86 SUSE LINUX Enterprise Serer 9 for AMD64/EM64T SUSE LINUX Enterprise Serer 9 for x86 Red Hat Red Hat Enterprise Linux 5 Serer x64 Edition Red Hat Enterprise Linux 5 Serer with Xen x64 Edition Red Hat Enterprise Linux 5 Serer Edition with Xen Red Hat Enterprise Linux 5 Serer Edition Red Hat Enterprise Linux 4 AS for AMD64/EM64T Red Hat Enterprise Linux 4 AS for x86 Red Hat Enterprise Linux 4 ES for AMD64/EM64T Red Hat Enterprise Linux 4 ES for x86 Red Hat Enterprise Linux 4 WS/HPC for AMD64/EM64T Red Hat Enterprise Linux 4 WS/HPC for x86 Red Hat Enterprise Linux 3 AS for AMD64/EM64T Red Hat Enterprise Linux 3 AS for x86 Red Hat Enterprise Linux 3 ES for AMD64/EM64T Red Hat Enterprise Linux 3 ES for x86 Red Hat Enterprise Linux 3 WS for AMD64/EM64T Red Hat Enterprise Linux 3 WS for x86 VMware: VMware ESX Serer, 4.0 VMware ESXi 4.0 VMware ESX Serer 3.5 VMware ESXi 3.5 Installing Dynamic System Analysis on remoable media You can install Dynamic System Analysis on remoable media, such as a CD, DVD, or USB flash drie. 8 Installation and User's Guide
21 About this task Updating system support Important: Ensure that the remoable media has enough free space to contain the Dynamic System Analysis. Perform these steps to install Dynamic System Analysis on remoable media: Procedure 1. Download the appropriate portable-edition package for the local operating system from the Dynamic System Analysis Web site at support/supportsite.wss/docdisplay?lndocid=serv-dsa&brandind= : ibm_utl_dsa_.r.m_portable_plaform.exe for Windows systems ibm_utl_dsa_.r.m_portable_plaform.bin for Linux systems where installation_directory is the path to the extracted installation files,.r.m is the ersion of Dynamic System Analysis, and platform is the supported operating system. 2. Insert or mount the remoable medium. 3. Copy the portable-edition package to the remoable media. You can update Online Dynamic System Analysis to add support for new systems by downloading System Enablement Packs (SEPs) from IBM. System Enablement Packs are collections of the files and driers needed to allow ToolsCenter tools to support new systems. This section describes how to check for and download System Enablement Packs using Online Dynamic System Analysis. About this task When using Online Dynamic System Analysis with a system that was released after the release of the tool, you will receie the following message: You might need to download an update for DSA to support this system. Use the -? or -h parameter for more information about downloading updates. Do you want to proceed anyway (function may be limited)? (Y/N) You can choose to continue with limited function, or you can check for and download updates that will allow Online Dynamic System Analysis to support the new system. Procedure 1. Optional: Check for new updates. You can check for new updates without downloading them using the chkupd parameter with the collectall command. For Windows: ibm_utl_dsa_.r.m_portable_plaform --chkupd or for Linux:./ibm_utl_dsa_.r.m_portable_plaform --chkupd If new updates are aailable, you will be prompted to update the support list. 2. Update the support list. The update parameter of the collectall command checks for updates, and if any are found, downloads them automatically. For Windows: ibm_utl_dsa_.r.m_portable_plaform --update For Linux: Chapter 2. Installing Dynamic System Analysis 9
22 ./ibm_utl_dsa_.r.m_portable_plaform --update When the update has been downloaded, it automatically added to the current binary leel of installable DSA, or to the directory of portable DSA in a new subdirectory named update. The next time portable DSA is run, it will detect the update, apply it, and continue, using the latest leel of support. 10 Installation and User's Guide
23 Chapter 3. Running diagnostic tests on the local system About this task Perform these steps to run diagnostics on the local system. 1. If you are using the Preboot Dynamic System Analysis GUI: a. Boot to the Dynamic System Analysis, either by booting to remoable media or, for preinstalled Dynamic System Analysis, pressing F2 to interrupt the boot sequence. b. Select Quit to DSA to exit the stand-alone memory diagnostic program. Note: After you exit the stand-alone memory diagnostic enironment, you must restart the system before you can access this enironment again. c. Enter gui or select Click here to start diagnostics (GUI) to launch the Dynamic System Analysis graphical enironment. d. Select Diagnostics from the left-hand naigation pane to open the Diagnostics panel. e. In the Diagnostics panel, click Add Test to open the All Tests window, which lists all aailable tests. f. Determine what tests will be run by using the Add Sel/All and Rem Sel/All buttons to add and remoe tests from the Test Items field. Test in this field will be run. g. When you are finished selecting tests, click Ok to return to the Diagnostics panel, which is now populated with the tests you selected. h. Click the hyperlink in the Loop column to set the loop count for test execution. i. Click Start Test to run the selected tests. j. When the tests are complete, click the Success hyperlink in the Status column to iew the results. 2. If you are using the Dynamic System Analysis Preboot Edition command-line interface: a. Boot to the Dynamic System Analysis, either by booting to remoable media or, for preinstalled Dynamic System Analysis, pressing F2 to interrupt the boot sequence. b. Enter cmd or select Click here to start diagnostics (CLI) to launch the Dynamic System Analysis command enironment. c. Select Diagnostics from the menu to enter the interactie diagnostics enironment. The options in this enironment are: Enumerate Aailable Diagnostic Tests lists the aailable diagnostics and deices. Execute Diagnostic Tests executes the selected tests. Get Diagnostic Extended Results displays the extended results of diagnostics tests that hae already run. d. When the tests are complete, enter :x to exit the menu. e. Select the completed tests to iew the results. Copyright IBM Corp. 2009,
24 3. If you are using Dynamic System Analysis on remoable media: a. Insert the media into the system, and if necessary, mount the remoable media. b. From a command line, change to the directory for the remoable media. c. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_plaform -diags where.r.m is the ersion of Dynamic System Analysis, and platform is the supported Linux distribution. 12 Installation and User's Guide
25 Chapter 4. Collecting system information You can use Dynamic System Analysis to collect system information and conert the collected data to another format. Collecting system information on the local system using Preboot Edition About this task Perform these steps to collect system information on the local system: 1. If you are using the Dynamic System Analysis Preboot Edition graphical user interface: a. Boot to the Dynamic System Analysis, either by booting to remoable media or, for preinstalled Dynamic System Analysis, pressing F2 to interrupt the boot sequence. b. Select Diagnostics from the naigation pane. c. Select Click here to start diagnostics (GUI) to start the graphical user interface. d. Select System inentory to launch the System Inentory page. e. Select the Automatic radio button to automatically collect all aailable data, or deselect it to control what information catalogs to use by adding them to or remoing them from the Data Set table. f. Click Begin to collect the data associated with the selected catalogs. 2. If you are using the Dynamic System Analysis Preboot Edition command-line interface: a. Boot to the Dynamic System Analysis, either by booting to remoable media or, for preinstalled Dynamic System Analysis, pressing F2 to interrupt the boot sequence. b. Select Diagnostics from the naigation pane. c. Click Click here to start diagnostics (CLI)to start the command-line interface. d. Select the Data Collection option to open the data collection menu. e. Select Collect to open the collection menu. You are asked whether to customize options. You can customize the following options: -: does not create compressed XML data as output. -x: creates HTML output. -dumpxml: creates a.xml.gz zipfile after each plugin. This preseres data already collected if an error occurs curing collection. f. When the collection is complete, select View collection resultsto display the results. g. When you are done, enter :q to exit the iewer. Copyright IBM Corp. 2009,
26 Collecting system information on the local system About this task Perform these steps to collect system information on the local system: 1. If you are using Dynamic System Analysis on remoable media: a. Insert the media into the system, and if necessary, mount the remoable media. b. From a command line, change to the directory for the remoable media. c. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_plaform [-x] [-] [-text] where.r.m is the ersion of Dynamic System Analysis, and platform is the supported operating system. This command creates compressed CIM-XML output by default. You can also create HTML output by specifying the - option and ASCII text output by specifying the -text option. If you specify the -x option, compressed CIM-XML output is not created, and you must specify the - or -text option, or both. Collecting system information on a WinPE image About this task Perform these steps to run all aailable nondestructie diagnostic tests on all aailable deices in the local system using the collectall command: 1. Boot the local system with the Windows Preinstallation Enironment (WinPE) CD. 2. If you are using Dynamic System Analysis on remoable media: a. Insert the media into the system, and if necessary, mount the remoable media. b. From a command line, change to the directory for the remoable media. c. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_plaform [-x] [-] [-text] where.r.m is the ersion of Dynamic System Analysis, and platform is the supported operating system. This command creates compressed CIM-XML output by default. You can also create HTML output by specifying the - option and ASCII text output by specifying the -text option. If you specify the -x option, compressed CIM-XML output is not created, and you must specify the - or -text option, or both Tip: You can edit the startnet.cmd file to run Dynamic System Analysis automatically after WinPE boots. Collecting system information on a remote system running the VMware ESXi Before you begin Prerequisites: 14 Installation and User's Guide
27 The remote system running with the VMware ESXi3.5 must be accessible by the system running DSA from network. The system running DSA must hae port 5989 open. About this task Perform these steps to collect system information on a remote system running the VMWare embedded hyperisor: 1. Insert the USB flash drie containing VMWare ESXi3.5 in the target system. 2. Boot the system. 3. Select DHCP or configure the IP address manually following VMWare instructions. 4. If you are using Dynamic System Analysis on remoable media: a. Insert the media into the system, and if necessary, mount the remoable media. b. From a command line, change to the directory for the remoable media. c. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_plaform -mwesxi user_id@ip_address[:port] where.r.m is the ersion of Dynamic System Analysis and user_id@ip_address[:port] specfies the user ID, IP address, and port number to use for authentication with the hyperisor.. Collecting IPMI eent logs from a remote system About this task Perform these steps to collect Intelligent Platform Management Interface (IPMI) eent logs from a remote system using out-of-band mode: 1. If you are using Dynamic System Analysis on remoable media: a. Insert the media into the system, and if necessary, mount the remoable media. b. From a command line, change to the directory for the remoable media. c. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_plaform -ipmilan system where.r.m is the ersion of Dynamic System Analysis, platform is the supported operating system, and system is the remote system to which you want to collect IPMI eent logs. Specify the system using the following format: user_id:password@ip_address[:port]. Conerting collected data to another format About this task Perform these steps to conert data collected on the local system to another format: 1. If you are using Dynamic System Analysis on remoable media: a. Insert the media into the system, and if necessary, mount the remoable media. b. From a command line, change to the directory for the remoable media. c. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_platform data_file [- -text] Chapter 4. Collecting system information 15
28 where:.r.m is the ersion of Dynamic System Analysis platform is the supported operating system data_file is the fully-qualified name of the compressed CIM-XML data file that you want to conert Specify - to conert the data to HTML format. Specify -text to conert the data to ASCII text format. 16 Installation and User's Guide
29 Chapter 5. Comparing system information You can use Dynamic System Analysis to compare collected system information. Comparing installed and latest ersions of firmware Before you begin Prerequisite: The local system must hae Internet access or access. About this task Perform these steps to compare the installed ersions of firmware and deice driers on the local system to the latest ersions aailable on the Web: 1. Insert the media into the system, and if necessary, mount the remoable media. 2. From a command line, change to the directory for the remoable media. 3. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_plaform -ux [-x] [-] [-text] where.r.m is the ersion of Dynamic System Analysis, and platform is the supported operating system. When the comparison is completed, the analysis is written to a compressed CIM-XML output file by default. You can also create HTML output by specifying the - option and ASCII text output by specifying the -text option. If you specify the -x option, compressed CIM-XML output is not created, and you must specify the - or -text option, or both. Note: Internet access is required for the -ux option. Comparing current system information to preiously collected data About this task Important: You can compare only system information that was collected using the same ersion of Dynamic System Analysis. Perform these steps to collect the system information on the local system and then compare the current system information to one or more system information files that were preiously collected: 1. Insert the media into the system, and if necessary, mount the remoable media. 2. From a command line, change to the directory for the remoable media. 3. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_plaform -r data_file - where.r.m is the ersion of Dynamic System Analysis, platform is the supported operating system, and where data_file is the fully-qualified name of the system information file that you want to compare. Separate multiple data files using a space. Copyright IBM Corp. 2009,
30 Comparing multiple system information files About this task Perform these steps to compare two or more system information files that were preiously collected: 1. Insert the media into the system, and if necessary, mount the remoable media. 2. From a command line, change to the directory for the remoable media. 3. Enter the following command to compare system information: ibm_utl_dsa_.r.m_portable_plaform -r data_file - where.r.m is the ersion of Dynamic System Analysis, platform is the supported operating system, and where data_file is the fully-qualified name of the system information file that you want to compare. Separate multiple data files using a space. If you specify the -i option, this command compares the specified data file against the data file specified by the -r option. If you do not specify the -i option, this command collects the current system information on the local system before comparing it against the data file specified by the -r option. 18 Installation and User's Guide
31 Chapter 6. Viewing collected system information About this task When you collect system information, Dynamic System Analysis saes the collected data in the specified output directory. If you do not specify a directory, Dynamic System Analysis stores the data files in the c:\ibm_support\ directory on Windows systems or /ar/log/ibm_support/ directory on Linux systems by default. To iew system information in HTML format If you specify the - format option, the ibm_utl_dsa_.r.m_portable_platform command saes the data in HTML format. By default, Dynamic System Analysis creates the set of HTML file in a subdirectory named outputdir/mtm_serialnumber_datetime, where outputdir is the default or specified output directory, mtm is the machine type and model of the local system, serialnumber is the serial number of local system, and datetime is the date and time when data was collected. To iew the HTML file, open the index.html file in a Web browser. The left pane contains links for each category of system information, and the right pane displays the related information. To iew system information in ASCII text format If you specify the -text format option, the ibm_utl_dsa_.r.m_portable_platform command saes the data in TXT format. To iew the text file, use any text editor. To iew system information in XML format If you do not specify a format option, the ibm_utl_dsa_.r.m_portable_platform command saes the data in XML format. To iew the XML file, decompress the XML file, and then open it using any text or XML editor. To conert an XML file to HTML format for easier iewing, run the following command: ibm_utl_dsa_.r.m_portable_platform - -x -i path/data_file.xml.gz where path is the fully qualified path and data_file is the name of the compressed XML file that was preiously created by Dynamic System Analysis. Copyright IBM Corp. 2009,
32 20 Installation and User's Guide
33 Chapter 7. Transferring data and logs You can use Dynamic System Analysis to transfer data and logs to a remote system, or to the Electronic Serices web portal for use in the My Systems and My Notifications functions. Transferring collected data to a remote system Use this procedure to send collected data to IBM Serice and Support or another remote system using File Transfer Protocol (FTP). About this task Perform these steps to transfer data collected on the local system to a remote system using FTP: 1. If you are using the Dynamic System Analysis Preboot Edition command-line interface: a. Collect data using the command-line interface as described in Collecting system information on the local system using Preboot Edition on page 13 and exit the iewer by typing :q. b. Select Quit to preious menu to exit the interactie Data Collection menu. c. Select Send System Information to IBM Serer from the numerical menu. You will be prompted to customize the FTP serer. d. Enter yto customize the serer information and specify the FTP address, port number, user name, and password to use with your FTP serer. 2. If you are using the Dynamic System Analysis Preboot Edition graphical user interface: a. Boot to Dynamic System Analysis, either by booting to remoable media or, for preinstalled Dynamic System Analysis, pressing F2 to interrupt the boot sequence. b. Select Diagnostics from the naigation. c. Select Collect Logs and Transfer to launch the Transfer page. d. Select Automatic to collect all data and automatically transfer it to IBM Serice and Support, or Select Manual to select which logs to collect and manually send them to IBM Serice and Support. 3. If you are using Dynamic System Analysis on remoable media: a. Insert the media into the system, and if necessary, mount the remoable media. b. From a command line, change to the directory for the remoable media. c. Enter the following command to collect system information: ibm_utl_dsa_.r.m_portable_plaform [-] [-t] system where.r.m is the ersion of Dynamic System Analysis, platform is the supported Linux distribution, and system is the remote system to which you want to transfer files, specified using the following format: user_id:password@ip_address[:port]/path/. If you do not specify a system, the data file is sent to IBM. Note: Port 21 must be enabled for access through the firewall to transfer logs to IBM. Copyright IBM Corp. 2009,
34 Transferring collected data to the IBM customer inentory repository Before you begin Prerequisite: The local system must hae Internet access to transfer the data file, and Port 443 must be enabled for traffic through your firewall. About this task Perform these steps to transfer data from the local system to the IBM customer inentory repository: 1. Insert the media into the system, and if necessary, mount the remoable media. 2. From a command line, change to the directory for the remoable media. 3. Enter the following command to collect system information and transfer the system information file: ibm_utl_dsa_.r.m_portable_platform -upload [-IBMid:user_id] where.r.m is the ersion of Dynamic System Analysis platform is the supported operating system. user_id is your IBM user ID. Note: If you do not specify -IBMid, you will be prompted for your user ID. Dynamic System Analysis erifies the IBM ID and if it is alid, adds it to the data file. If the ID is not alid, or no ID is specified, the data file is transferred, but the ID is not included. 22 Installation and User's Guide
35 Chapter 8. Troubleshooting and support Use this section to troubleshoot and resole problems with Dynamic System Analysis. For solutions to problems that other customers hae encountered, see the IBM System x Forum customer forum at forum.jspa?forumid=740. Known limitations, problems, and workarounds This section describes limitations, problems, and workarounds that are applicable to Dynamic System Analysis. See the README file for the ersion of Dynamic System Analysis that you are using for the most recent limitations, problems, and workarounds. On systems where the serice processor clock does not hae the same timezone settings as the local system, the merged log might appear to be out of order. The entries are sorted correctly but appear incorrect because the timezone setting is not displayed. When Dynamic System Analysis collects dates and times that are before January 1, 1970, 00:00:00, or after January 19, 2038, 03:14:07, Dynamic System Analysis reports these dates and times as January 1, 1970, 00:00:00. These dates fall outside the alid range for a date in Dynamic System Analysis. Dynamic System Analysis might report the memory speed as "Unknown" in the Memory section of the Hardware Information report. This is due to issues with SMBIOS support on some systems. For the System x225 and Intellistation Z10 systems, the PCI Information report might misrepresent which slot a PCI deice is in due to an SMBIOS issue. Due to a limitation in HS40(8839), Dynamic System Analysis can determine the status of only the system error LED. No other LEDs are aailable. Due to a limitation in System x206m and x306m, Dynamic System Analysis cannot determine the status of the system LEDs. No LEDs are aailable for collection. For the System x3550 systems, the system fans are physically attached together as pairs, and each pair has a single LightPath LED attached. The Dynamic System Analysis LightPath report displays each pair of fans as a single fan LED. For the IntelliStation A10 systems, the Processor section of the Hardware Information report does not display cache information for secondary processors. This is due to an issue with the SMBIOS support. If you are running Dynamic System Analysis on a multi-node IBM Systems serer such as System x460 systems, Dynamic System Analysis cannot specify to which node certain hardware belongs. This is due to limitations of either Windows APIs or SMBIOS. The System x460 appears to Windows and SMBIOS as a single, complete system and not as split up into nodes. Also, because LightPath and IPMI logs are populated only by the primary node, specific details regarding non-primary nodes are not collected. Dynamic System Analysis collects CPLD firmware leels (such as Super I/O card firmware, PCI-X card firmware, CPU card firmware) on systems that hae CPLD. Information about the indiidual CPLD firmware leels ersus the CPLD package ersion on the web (such as ersion 1.06) can be obtained in Copyright IBM Corp. 2009,
36 er_chk.txt, which is located on each CPLD disk. The first column in this file is the SIO card CPLD ersion. The second column is the PCI-X card CPLD ersion. The third column is the CPU card CPLD ersion. The last column is the oerall disk ersion number. The IPMI deice drier must be installed to collect IPMI BIST information. GoVault (part number 25R0006) is not recognized as a tape drie in DSA Diagnostics (ersion 2.02 and prior) and does not appear in the tape drie section of the HTML iewer. GoVault appears as a hard disk due to the hardware implementation and deice drier. DSA can recognize the deice, but it is listed in the disk drie section. For the HS20 and LS20 systems, the DSA Lightpath report shows the System LED as being off, een if the associated physical LED is lit. When you run Dynamic System Analysis with the -ux option on HC10 (7996), there are no BIOS and BMC firmware comparison result in UpdateXpress section. When you run Dynamic System Analysis with -ux option, the ATI ideo drier comparison result in UpdateXpress might be downleel. For example, for drier ATI2MTAG.SYS, it shows for the latest ersion. It should be For the latest firmware and drier updates, see When you run Dynamic System Analysis with the -ux option on Windows XP or Windows Vista, the result in UpdateXpress section might not be aailable or might not be accurate. When you run Dynamic System Analysis with the -ux option on LS20 (8850), the BIOS comparison result in UpdateXpress section might be downleel. For example, it shows the latest ersion is 1.28 but it should be Also, the SereRaid drier comparison might be downleel. For example, it shows the latest ersion of NFRD960.SYS as but it should be For the latest firmware and drier updates, see Memory Manufacturer information is missing on HS21. Current State in LED Settings cannot report some failure of DIMM in LS21 and LS41. Check the IPMI eent, and get the failure DIMM eent. Some SMART Attributes in Drie Health might be missing in idataplex (7321, 7322). HS22(7870/1936) does not support QLogic FC Controller. 24 Installation and User's Guide Configuration LED is missing from Lightpath Information in System x3650 (7979, 1914) and System x3550 (1913). For HS22 (7870, 1936), idataplex (7321, 7322), System x3650 M2 (7947), and System x3550 M2 (7946), if the RNDIS drier is not installed, enironmental data and chassis eent logs are not collected. RNDIS drier can be installed automatically when imm Firmware update in the operating system. If you update imm FW from the imm website, RNDIS drier is not installed on the operating system. In this case, manually install RNDIS, or SP configuration Chassis eent log and enironment data cannot be collected. For HS22 (7870, 1936), idataplex (7321, 7322), System x3650 M2 (7947), and System x3550 M2 (7946), irtual disk is created by Integrated Management Module. Broadcom Firmware info cannot be collected in System x260, x3800, x460 and x3950 on VMware ESX 3.5 serer. LSI RAID configured as leel 1E is recognized as leel 1 in DSA data collection. UpdateXpress function specified by the -ux option when running DSA is not supported on the following systems: System x335, x336, Intellistation Z20, Z40, M30, M40, M50, idataplex dx320, dx340, and dx360.
37 (Installable edition only) When you run Dynamic System Analysis with the -ux option on HS12, the result in UpdateXpress for LSI 1064e SAS controller might not be accurate. It shows the latest leel is but actually it should be (Portable edition only) When you run Dynamic System Analysis with the -ux option on x346 (8840), the result in UpdateXpress for deice drier file NFRD960.SYS is But actually it should be (Portable edition only) When you run Dynamic System Analysis with the -ux option on HS12 (8014, 8028, 1916), the result in UpdateXpress for LSI 1064e SAS controller might not be accurate. It shows the latest leel is but it should be (Linux only) The openipmi drier on SLES10 supports a maximum 4 BMCs on multinode. (Linux only) UpdateXpress function does not work on SLES10 32bit and 64bit operating systems. If you need to compare ersion, refer to the -i option. (Linux only) QLogic iscsi Controller information cannot be collected in SLES10 Realtime and RedHat5 Realtime. (Linux only) In the DSA PCI information page, PCI deices might miss the corresponding mappings of PCI slots on ESX 3.5 serer. (Linux only) IPMI drier works only on RedHat 4 U7 or later on multi-node system. (Linux only) IPMI drier works only on VMware 3.5 U3 or later on multi-node system. (Linux only) QLogic iscsi Controller cannot be collected in SLES10 Realtime OS and RedHat5 Realtime OS. (Linux only) Certain, rare conditions on the SCSI bus might temporarily preent Dynamic System Analysis from collecting sense data from SCSI-attached tape deices. In the eent that this data is not collected on a system with a SCSI-attached tape deice, run Dynamic System Analysis again to collect the data. (Linux only) The Merged Deices report is not aailable on RedHat Enterprise Linux due to operating system limitations. (Linux only) The SereRAID report might report the number of logical dries as 1, while SereRAID Manager reports the number of logical dries as 0. This is due to an issue with the tool used by Dynamic System Analysis to collect this data. (Linux only) The SLES9 64-bit installation does not create a link to libcurl.so in /usr/lib64. To use the FTP transport feature, create a symbolic link from libcurl.so to libcurl.so (Linux only) The OpenIPMI drier must be upgraded to ersion on SLES9 SP2 to collect IPMI logs and other serice processor information using Dynamic System Analysis. (Linux only) Dynamic System Analysis is not able to collect firmware information from the Broadcom NX2 (NetXtreme II) network adapter due to limitations of the current Broadcom BMAPI interface. (Linux only) For the System x226 system, the firmware/vpd report might erroneously report that there is an RSA card installed. This is due to an issue with the SMBIOS support. (Linux only) On systems running Linux for x86_64, Dynamic System Analysis might not be able to determine PCI slot information due to a limitation in BIOS. This affects the following machine types: IBM System x346, x336, x460, x366, and x260. Chapter 8. Troubleshooting and support 25
38 (Linux only) On the Intellistation M40, M50, and Z20, Dynamic System Analysis does not obtain information for the monitor. Data such as model, manufacturer, manufacturing date, resolution, refresh rate, and scan mode for the monitor are not be aailable in Hardware Inentory. (Linux only) During normal Dynamic System Analysis operation, entries are written to the system messages log (/ar/log/messages). By default, these messages are also written to the root console of the system. This is a normal side-effect of DSA operation and the messages, including any errors, can be safely ignored. (Linux only) Dynamic System Analysis cannot collect SMART data from SATA disk dries that are using the Linux libata driers. This is due to limitations of the libata drier. (Linux only) On systems with PCI Express slots, the type of slot might be listed as "Other." These slots are not associated with the appropriate PCI deice that might be in the PCI Express slot. (Windows only) Slot of PCI-E and PCI adapters are blank in the PCI information Section in System x3400 and x3500 (7973, 7974, 7975, 7976, 7977), System x3200 M2 (4367, 4368, 9233, 9234), System x3250 M2 (4190, 4191, 4194), and System x3350 (4192, 4193) on Windows The future BIOS release will fix this issue. (Windows only) Dynamic System Analysis Installable Edition is not supported on Windows PE (both 32-bit and 64-bit). (Windows only) When Dynamic System Analysis is installed on a Windows 2000 system that does not hae Windows Serice Pack 3 or later installed, Dynamic System Analysis does not display a message stating that Serice Pack 3 or later is required. Instead, it displays the following message: 1155:Couldn't find file InstMsiw.exe. To aoid this message, install Windows Serice Pack 3 or later before installing Dynamic System Analysis. (Windows only) When an adapter is remoed from the system that was preiously configured in a network irtual team using the Intel PROSet software package, DSA might report that the adapter is still present with a corrupt MAC address. Disregard the information returned for this adapter. (Windows only) On 64-bit editions of Windows, Dynamic System Analysis does not collect firmware and ASF information for Broadcom network controllers. This is due to a limitation of the current Broadcom BMAPI interface. (Windows only) Using Windows HPC serer edition, all RSA nodes are not aailable on x3950, x3850m2 and x3950m2. (Windows only) Using Microsoft Windows 2003 or Windows 2008 Enterprise edition, all RSA nodes are not aailable on x3950, x3850m2 and x3950m2. See the IBM SererProen Web site at sererproen/compat/us/ for specific operating-system support per system. (Windows only) Using Microsoft WindowsPE all RSA nodes and BMC nodes are not aailable on System x3950, x3850 M2 and x3950 M2. See the IBM SererProen Web site at us/ for specific operating-system support per system. (Windows only) Window components and installed hotfixes cannot be collected in Windows Installation and User's Guide
39 Dynamic System Analysis eent log All diagnostic test status and error information is recorded in the DSA eent log. Each log record contains: Time stamp Source Message type Message text You can set the name and location of the log file using the DSA_LOGFILE enironment ariable. This ariable takes a string that contains a alid path on the system on which DSA is running. The file does not need to exist, but the path to the file must exist. If this ariable is not set, logging will be lost. Dynamic System Analysis core dump file A core dump file might be created when Dynamic System Analysis ends unexpectedly. On Windows, the core dump file, name DSA_CORE.dmp, is created in the directory where DSA was run. On Linux, the core dump is disabled by default. To enable core dump to be created, run the ulimit c command. When enabled, the core dump file, named with random numbers such as dump01043, is created in the directory where DSA was run. Getting help and technical assistance Use this information to locate technical assistance for your IBM System x and BladeCenter tools. About this task If you need help, serice, or technical assistance or just want more information about IBM products, you will find a wide ariety of sources aailable from IBM to assist you. This section contains information about where to go for additional information about IBM and IBM products, what to do if you experience a problem with your system, and whom to call for serice, if it is necessary. Before you call Use this information before you call Serice and Support and report a problem. About this task Before you call, make sure that you hae taken these steps to try to sole the problem yourself: Ensure that you hae the latest ersion of the tool installed. Check all cables to make sure that they are connected. Check the power switches to make sure that the system and any optional deices are turned on. Use the troubleshooting information in your system documentation, and use the diagnostic tools that come with your system. Chapter 8. Troubleshooting and support 27
40 Go to the IBM support Web site at to check for technical information, hints, tips, and new deice driers. Use an IBM discussion forum on the IBM Web site to ask questions. You can sole many problems without outside assistance by following the troubleshooting procedures that IBM proides in the online help or in the documentation that is proided with your IBM product. The documentation that comes with IBM systems also describes the diagnostic tests that you can perform. Most systems, operating systems, and programs come with documentation that contains troubleshooting procedures and explanations of error messages and error codes. If you suspect a software problem, see the documentation for the operating system or program. Using the documentation Use this information for locating detailed information on using the documentation. About this task Information about your IBM system and preinstalled software, if any, or optional deice is aailable in the documentation that comes with the product. That documentation can include information centers, online documents, printed documents, readme files, and help files. See the troubleshooting information in your system documentation for instructions for using the diagnostic programs. The troubleshooting information or the diagnostic programs might tell you that you need additional or updated deice driers or other software. IBM maintains pages on the World Wide Web where you can get the latest technical information and download deice driers and updates. To access these pages, go to the IBM support Web site at and follow the instructions. Also, some documents are aailable through the IBM Publications Center Web site at Documentation for IBM System x and BladeCenter tools are aailable in the IBM ToolsCenter Web site at Getting help and information from the World Wide Web Use this information to find the latest information about IBM systems, optional deices, serices, and support. About this task On the World Wide Web, the IBM Web site has up-to-date information about IBM systems, optional deices, serices, tools, and support. The address for IBM System x information is The address for IBM BladeCenter information is The address for IBM IntelliStation information is You can find serice information for IBM systems and optional deices at Software serice and support Use this information to contact IBM serice and support with questions about your IBM System x and BladeCenter tools. 28 Installation and User's Guide
41 About this task Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with System x serers, BladeCenter products, IntelliStation workstations, and appliances. For information about which products are supported by Support Line in your country or region, see serices/sl/products/. For more information about Support Line and other IBM serices, see or see for support telephone numbers. In the U.S. and Canada, call IBM-SERV ( ). Hardware serice and support Use this contact information to order new equipment or request IBM serice support. About this task You can receie hardware serice through IBM Serices or through your IBM reseller, if your reseller is authorized by IBM to proide warranty serice. See support telephone numbers, or in the U.S. and Canada, call IBM-SERV ( ). In the U.S. and Canada, hardware serice and support is aailable 24 hours a day, 7 days a week. In the U.K., these serices are aailable Monday through Friday, from 9 a.m. to 6 p.m. Chapter 8. Troubleshooting and support 29
42 30 Installation and User's Guide
43 Appendix A. Accessibility features for Dynamic System Analysis Accessibility features help users who hae a disability, such as restricted mobility or limited ision, to use information technology products successfully. Accessibility features The following list includes the major accessibility features in Dynamic System Analysis: Can be operated using only the keyboard Communicates all information independent of color Supports the attachment of alternate output deices Proides help information in an accessible format (Microsoft Windows systems only) Supports interfaces commonly used by screen readers and screen magnifiers The Dynamic System Analysis topic collection in the IBM ToolsCenter for System x and BladeCenter information center, and its related publications, are accessibility-enabled. Keyboard naigation This product uses standard Microsoft Windows naigation keys. IBM and accessibility See the IBM Human Ability and Accessibility Center Web site for more information about the commitment that IBM has to accessibility. Copyright IBM Corp. 2009,
44 32 Installation and User's Guide
45 Appendix B. Dynamic System Analysis commands How to read syntax diagrams DSA command You can preform all Dynamic System Analysis functions from a command-line interface. Reiew the conentions used in syntax diagrams to understand the command descriptions. The syntax diagram consists of options and option arguments. Options consist of a hyphen and single letter (for example, -h) or two hyphens and multiple letters (for example, -- help). Options can be followed by one or more option arguments (for example, as illustrated in [--cd=olume]. Consider these conentions when reading syntax diagrams: Options that are enclosed in brackets ([]) are optional. Do not include these brackets in the command. Options that are enclosed in braces ({}) are required. Do not include these braces in the command. Options that are not enclosed in either brackets or braces are required. The names of options are case sensitie and must be typed exactly as shown Options preceded by two dashes (--) must be specified in their entirety. The names of option arguments that require substitution by actual alues are italicized. The pipe ( ) character signifies that you choose one option or the other. For example, [a b]indicates that you can choose either a or b, but not both. Similarly, {a b}indicates that you must choose either a or b. An ellipsis (...) signifies that you can repeat the option argument on the command line. Use the ibm_utl_dsa_.r.m_portable_platform command to collect information about the local system. Syntax ibm_utl_dsa_.r.m_portable_platform -? -h ibm_utl_dsa_.r.m_portable_platform -l ibm_utl_dsa_.r.m_portable_platform -b ibm_utl_dsa_.r.m_portable_platform -diags ibm_utl_dsa_.r.m_portable_platform --chkupd --proxy-address=ip_address --proxy_port=portnum --proxy-user=userid --proxy-password=password ibm_utl_dsa_.r.m_portable_platform [-i data_file] Copyright IBM Corp. 2009,
46 ibm_utl_dsa_.r.m_portable_platform -r [data_file] -[-i data_file] ibm_utl_dsa_.r.m_portable_platform -t -i data_file ibm_utl_dsa_.r.m_portable_platform -update ibm_utl_dsa_.r.m_portable_platform -ux [-x] [-] [-text] ibm_utl_dsa_.r.m_portable_platform -ipmilan ibm_utl_dsa_.r.m_portable_platform -mwesxi ibm_utl_dsa_.r.m_portable_platform [-x] [-text] [- [-html]] [-i data_file] [-d output_directory [-c]] [-dumpxml] [-f] ibm_utl_dsa_.r.m_portable_platform --update --proxy-address=ip_address --proxy_port=portnum --proxy-user=userid --proxy-password=password ibm_utl_dsa_.r.m_portable_platform -upload [IBMid:id] Description Important: To install or use Dynamic System Analysis, you must be logged in to the local system using a user ID that has administrator or root priileges. On a Linux system, you must log in using the root user name and priilege. On Linux systems, you must run Dynamic System Analysis from a journaling file system (such as ext3 or ReiserFS). You cannot run these commands from a irtual machine file system (VMFS). To run this command on a system running Windows, change to the directory where Dynamic System Analysis was installed (for example, C:\Program Files\IBM\DSA). Use ibm_utl_dsa_.r.m_portable_platform.exe to run this command. To run this command on a system running Linux, Use ibm_utl_dsa_.r.m_portable_platform. If no options are specified, this command collects and saes information in a compressed XML file in the installation_directory\ibm_support\ on Windows systems or /ar/log/ibm_support on Linux systems. This file contains the collected data and the consolidated property specification documents from each collector that collects data. The file is named mtm_serialnumber_datetime.xml.gz, where mtm is the machine type and model number of the local system, serialnumber is the serial number of the local system, and datetime is the date and time that data was collected. If Dynamic System Analysis cannot obtain a alid machine type, model number, or serial number of the system, any resultant output file and subdirectory will use the string "Unknown" in place of these alues. For more information about the standard of CIM-XML specifications, see the CIM Web-Based Enterprise Management (WBEM) Web site at standards/wbem/. 34 Installation and User's Guide
47 Commands and options -b Runs in batch (unattended) mode. When this option is specified, user-interactie prompts are not displayed. -c Creates the output directory specified by -d option if it doesn't already exist. If the directory does exists, this option has no effect. --chkupd --proxy_address=ip_address --proxy_port=portnum --proxy_user=userid --proxy_password=password Checks the IBM web site for aailable System Enablement Packs (SEPs). You can add support for new deices by downloading and installing new SEPs. This function is aailable for Online Dynamic System Analysis only. proxy_address= The IP address of the proxy serer used to connect to the Internet. proxy_port= The port number on the proxy serer. proxy_user= The username to connect to the proxy serer. proxy_password= The password for the proxy_user. -d output_directory Specifies the fully-qualified or relatie directory where the data files are to be placed (for example: /tmp/dsa or c:\temp\dsa for Windows) Important: If you do not specify the -c option, the specified output directory must exist on the local system. -diags Runs all nondestructie diagnostics tests for the applicable deices. The nondestructie diagnostic tests include: Optical drie tests, including erify media, read error, and drie self test Tape drie tests, including tape presence, tape alert, tape load, and tape self test --disable-imm-lan Disables the USB Oer LAN interface after running DSA. -dumpxml Saes the compressed CIM-XML file to disk after each collector plug-in runs. Tips: This option significantly slows down the collection process and is intended only for debugging purposes. This option cannot be used with the -x and -i options. -f Collects the full ISMP serice processor log. -? -h Displays information about this command, including syntax and option descriptions. -html output_directory Specifies the fully-qualified or relatie directory where the HTML data files are to be placed (for example: /tmp/dsa or c:\temp\dsa for Windows) Tips: Appendix B. Commands 35
48 36 Installation and User's Guide If you do not specify this option, the set of HTML data files is saed in the outputdir\mtm_serialnumber_datetime directory, where outputdir is the output directory specified by the -d option, mtm is the machine type and model of the local system, serialnumber is the serial number of local system, and datetime is the date and time when data was collected. If you do not specify the -c option, the specified output directory must exist on the local system. -i data_file Targets the existing compressed CIM-XML data file, specified using fully-qualified name, instead of collecting data on the current system. -ipmilan Collects IPMI eent log on the specified remote serer using out-of-band mode. -l Displays the license text. -r data_file[ data_file...] Compares current system information against one or more specified system information files, in compressed CIM-XML format. Use fully-qualified file names (for example, /tmp/compfile.xml.gz or c:\temp\dsa\compfile.xml.gz). Separate multiple file names using a space. Tip: If you specify the -r option, you must also specify the - option, which creates output in HTML format. If the -i option is also specified, this command compares the data files specified with the -r option to the current data file specified by the -i option instead of collecting the current system information. -t [user_id:password@ip_address[:port] /path/] Transfers the inentory data file to the specified system using the specified File Transfer Protocol (FTP). Specify the system using these arguments: user_id:password The credentials needed to access the FTP serer. ip_address The IP address or host name of the FTP serer. port The port number to use to access of the FTP serer. path The directory on the FTP serer in which you want to copy the inentory data files. Tip: If you specify this option with no arguments, the data file is transferred to the testcase.boulder.ibm.com/eserer/toibm/xseries/ FTP serer by default. -text Creates output in ASCII text format. Collected data is placed in the output directory in a single text file named mtm_serialnumber_datetime.txt, where mtm is the machine type and model number of the local system, serialnumber is the serial number of the local system, and datetime is the date and time that data was collected. Data is grouped in to high-leel categories (for example, system oeriew, network settings, and installed application). Related system information for the high-leel categories is categorized further and printed into seeral tables that contain properties and their alue.
49 --update --proxy_address=ip_address --proxy_port=portnum --proxy_user=userid --proxy_password=password Checks for aailable System Update Packs on the IBM support site, and downloads them if they are aailable. System Update Packs allow you to add support for systems that hae been released since the most recent release of Dynamic System Analysis. This function is aailable for Online Dynamic System Analysis only. proxy_address= The IP address of the proxy serer used to connect to the Internet. proxy_port= The port number on the proxy serer. proxy_user= The username to connect to the proxy serer. proxy_password= The password for the proxy_user. -upload [IBMid:id] Sends inentory data to the Electronic Serices web portal for use in proactie support functions such as My Systems and My Notifications. The data is sent using HTTPS. The IBM ID is the ID that is authorized to iew the inentory data sent using the Electronic Serices web portal page. If you specify this option with no IBM ID, the data is sent, but you will not be able to access it using the Electronic Serices web portal. -ux Compares the installed firmware leels and latest ersion of firmware leels in the UpdateXpress database on the Web. Important: The local system must hae Internet access. - Creates output in HTML format. Collected data is categorized and placed in a set of HTML files (for example, system_oeriew.html for system-oeriew information, net.html for network settings information, and installedapp.html for installed-application information). In each HTML file, related system information is categorized further and printed into seeral tables that contain properties and their alue. This option also creates an index.html file from which you can iew all system information. When you display this file in a Web browser, the left pane contains links for each category of information, and the right pane displays the related information. Tip: This option will commonly be used with the i option, but will not require the i option. -mwesxi user_id:password@ip_address[:port] Collect system information from the specified remote system running VMware ESXi 3.5. Tip: This option cannot be used with the -ipmilan, -r, -diags, and -f options. -x Does not create output in the compressed CIM-XML format. Tip: Appendix B. Commands 37
50 This command creates output in the compressed CIM-XML format by default. Examples If you specify the -x option, you must specify either the - or -text options. 1. Collect data in a compressed CIM-XML output This example illustrates how to collect data in a compressed CIM-XML file in the installation_directory\ibm_support\ on Windows systems or /ar/log/ibm_support on Linux systems. Windows ibm_utl_dsa_.r.m_portable_platform.exe Linux ibm_utl_dsa_.r.m_portable_platform 2. View preiously collected data This example illustrates how to import an existing data file named system1.xml.gz in the default output directory C:\Program Files\IBM\DSA\IBM_Support\ and then saes the data in HTML and text format. Windows ibm_utl_dsa_.r.m_portable_platform.exe -i input Linux ibm_utl_dsa_.r.m_portable_platform -i system1.xml.gz 3. Conert collected data into HTML and text output This example illustrates how to import an existing data file named system1.xml.gz in the default output directory C:\Program Files\IBM\DSA\IBM_Support\ and then saes the data in default output directory in HTML and text format. Windows Linux ibm_utl_dsa_.r.m_portable_platform.exe - -text -i input ibm_utl_dsa_.r.m_portable_platform - -text -i system1.xml.gz 38 Installation and User's Guide
51 Appendix C. Enironment ariables These enironment ariables are used by Dynamic System Analysis. DSA_INCLUDE Specifies one or more plug-ins that are to be included when collectall is run. Separate the plug-ins by a space, comma, or semi-colon. Use the base plug-in name (for example, Ddinfo;installedapps). Tip: The plug-in names are displayed when collection occurs. The DSA_INCLUDE and DSA_EXCLUDE ariables are mutually exclusie. To reset the effect of this enironmental ariables, set empty alues to the ariables (for example, DSA_INCLUDE=). Attention: Do not change this enironment ariable. This ariable is used for debugging and is intended for use only by IBM technical support. DSA_EXCLUDE Specifies one or more plug-ins that are to be excluded when collectall is run. Separate the plug-ins by a space, comma, or semi-colon. Use the base plug-in name (for example, Ddinfo;installedapps). Tip: The plug-in names are displayed when collection occurs. The DSA_INCLUDE and DSA_EXCLUDE ariables are mutually exclusie. To reset the effect of this enironmental ariables, set empty alues to the ariables (for example, DSA_INCLUDE=). Attention: Do not change this enironment ariable. This ariable is used for debugging and is intended for use only by IBM technical support. DSA_LOGLEVEL Indicates the leel of detail requested for logging. You can specify one of these alues: 0: Error 1: Warning 2: Status 3: Debug 4: Verbose Attention: Do not change this enironment ariable. This ariable is used for debugging and is intended for use only by IBM technical support. DSA_LOGFILE Specifies the path and file name for the DSA eent log. Important: The path must exist on the local system on which DSA is running. If this ariable is not defined, logging may be lost. Copyright IBM Corp. 2009,
52 40 Installation and User's Guide DSA_EVENTLOG_MAX Specifies the maximum number of entries collected from each system eent log. The alue must be a positie integer with six or few digits. The default alue is
53 Notices This information was deeloped for products and serices offered in the U.S.A. IBM may not offer the products, serices, or features discussed in this document in other countries. Consult your local IBM representatie for information on the products and serices currently aailable in your area. Any reference to an IBM product, program, or serice is not intended to state or imply that only that IBM product, program, or serice may be used. Any functionally equialent product, program, or serice that does not infringe any IBM intellectual property right may be used instead. Howeer, it is the user's responsibility to ealuate and erify the operation of any non-ibm product, program, or serice. IBM may hae patents or pending patent applications coering subject matter described in this document. The furnishing of this document does not grant you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing IBM Corporation North Castle Drie Armonk, NY U.S.A. For license inquiries regarding double-byte (DBCS) information, contact the IBM Intellectual Property Department in your country or send inquiries, in writing, to: IBM World Trade Asia Corporation Licensing 2-31 Roppongi 3-chome, Minato-ku Tokyo , Japan The following paragraph does not apply to the United Kingdom or any other country where such proisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-ibm Web sites are proided for conenience only and do not in any manner sere as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it beliees appropriate without incurring any obligation to you. Copyright IBM Corp. 2009,
54 Licensees of this program who wish to hae information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which has been exchanged, should contact: IBM Corporation MW9A/ Cottle Road San Jose, CA U.S.A. Such information may be aailable, subject to appropriate terms and conditions, including in some cases, payment of a fee. The licensed program described in this information and all licensed material aailable for it are proided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement, or any equialent agreement between us. Any performance data contained herein was determined in a controlled enironment. Therefore, the results obtained in other operating enironments may ary significantly. Some measurements may hae been made on deelopment-leel systems and there is no guarantee that these measurements will be the same on generally aailable systems. Furthermore, some measurements may hae been estimated through extrapolation. Actual results may ary. Users of this document should erify the applicable data for their specific enironment. Information concerning non-ibm products was obtained from the suppliers of those products, their published announcements or other publicly aailable sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-ibm products. Questions on the capabilities of non-ibm products should be addressed to the suppliers of those products. All statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objecties only. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of indiiduals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. If you are iewing this information softcopy, the photographs and color illustrations may not appear. Trademarks IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and serice names might be trademarks of IBM or other companies. A current list of IBM trademarks is aailable on the Web at Copyright and trademark information at Adobe and the Adobe logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries. 42 Installation and User's Guide
55 Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a registered trademark of Linus Toralds in the United States, other countries, or both. Microsoft and Windows are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product, or serice names may be trademarks or serice marks of others. Notices 43
56 44 Installation and User's Guide
57 Index A accessibility features 31 keyboard 31 shortcut keys 31 C command 39 software ibm_utl_dsa<arname>.r.m_portable_platform</arname> requirements 6 33 contacting support 23 conentions, syntax diagram 33 core dump file 27 D disability 31 Dynamic System Analysis installing 3 E eent log 27 F features, accessibility 31 H hardware requirements 3 supported 4 R requirements hardware 3 software 6 S shortcut keys 31 soling problems 23 support, contacting 23 supported hardware 4 supported operating systems 7 syntax diagram conentions 33 T trademarks 42 troubleshooting 23 U Updating support 9 W web resources i I installingdynamic System Analysis 3 K keyboard 31 L legal notices 41 log eents 27 O operating systems, supported 7 P problem soling 23 Copyright IBM Corp. 2009,
58 46 Installation and User's Guide
59 Readers Comments We'd Like to Hear from You IBM Systems Dynamic System Analysis Installation and User's Guide Version 3.1 We appreciate your comments about this publication. Please comment on specific errors or omissions, accuracy, organization, subject matter, or completeness of this book. The comments you send should pertain to only the information in this manual or product and the way in which the information is presented. For technical questions and information about products and prices, please contact your IBM branch office, your IBM business partner, or your authorized remarketer. When you send comments to IBM, you grant IBM a nonexclusie right to use or distribute your comments in any way it beliees appropriate without incurring any obligation to you. IBM or any other organizations will only use the personal information that you supply to contact you about the issues that you state on this form. Comments: Thank you for your support. Send your comments to the address on the reerse side of this form. If you would like a response from IBM, please fill in the following information: Name Address Company or Organization Phone No. address
60 Readers Comments We'd Like to Hear from You Fold and Tape Please do not staple Fold and Tape BUSINESS REPLY MAIL FIRST-CLASS MAIL PERMIT NO. 40 ARMONK, NEW YORK POSTAGE WILL BE PAID BY ADDRESSEE International Business Machines Corporation ATTN: Dept D06A PO Box Research Triangle Park, NC USA NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES Fold and Tape Please do not staple Fold and Tape Cut or Fold Along Line Cut or Fold Along Line
61
62 Printed in USA
Remote Supervisor Adapter II. Installation Instructions for Linux Users
Remote Superisor Adapter II Installation Instructions for Linux Users Remote Superisor Adapter II Installation Instructions for Linux Users Third Edition (October 2003) Copyright International Business
IBM Sterling Gentran Server for Windows. Quick Start Guide. Version 5.3.1
IBM Sterling Gentran Serer for Windows Quick Start Guide Version 5.3.1 IBM Sterling Gentran Serer for Windows Quick Start Guide Version 5.3.1 This edition applies to the 5.3.1 ersion of IBM Sterling Gentran:Serer
IBM ServerGuide Scripting Toolkit, Windows Edition. User's Reference
IBM SererGuide Scripting Toolkit, Windows Edition ser's Reference Version 9.00 IBM SererGuide Scripting Toolkit, Windows Edition ser's Reference Version 9.00 Note: Before using this information and the
IBM Tivoli Monitoring Version 6.3 Fix Pack 2. Windows OS Agent Reference
IBM Tioli Monitoring Version 6.3 Fix Pack 2 Windows OS Agent Reference IBM Tioli Monitoring Version 6.3 Fix Pack 2 Windows OS Agent Reference Note Before using this information and the product it supports,
Tivoli Storage Manager for Windows
Tioli Storage Manager for Windows Version 6.1 Installation Guide GC23-9785-01 Tioli Storage Manager for Windows Version 6.1 Installation Guide GC23-9785-01 Note Before using this information and the product
Readme File for IBM Tivoli Service Automation Manager Extension for Workload Automation. Version 8.6
Readme File for IBM Tioli Serice Automation Manager Extension for Workload Automation Version 8.6 ii Readme File for IBM Tioli Serice Automation Manager Extension for Workload Automation Contents Chapter
WebSphere Message Broker. Installation Guide. Version7Release0
WebSphere Message Broker Installation Guide Version7Release0 WebSphere Message Broker Installation Guide Version7Release0 About this book This book explains how to install WebSphere Message Broker Version
ThinkServer RD350 and RD450 Operating System Installation Guide
ThinkServer RD350 and RD450 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and
IBM Storage Management Pack for Microsoft System Center Operations Manager (SCOM) Version 2.4.0. User Guide GC27-3909-11
IBM Storage Management Pack for Microsoft System Center Operations Manager (SCOM) Version 2.4.0 User Guide GC27-3909-11 Note Before using this document and the product it supports, read the information
ThinkServer RD540 and RD640 Operating System Installation Guide
ThinkServer RD540 and RD640 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and
ERserver. Single signon. iseries. Version 5 Release 3
ERserer iseries Single signon Version 5 Release 3 ERserer iseries Single signon Version 5 Release 3 Note Before using this information and the product it supports, be sure to read the information in Notices,
Tivoli Identity Manager Server
Tioli Identity Manager Serer Version 5.1 Installation and Configuration Guide SC27-2410-01 Tioli Identity Manager Serer Version 5.1 Installation and Configuration Guide SC27-2410-01 Note: Before using
IBM Rapid Restore Ultra Version 4.0. User s Guide
IBM Rapid Restore Ultra Version 4.0 User s Guide IBM Rapid Restore Ultra Version 4.0 User s Guide Notice: Before using this information and the product it supports, be sure to read Notices and Trademarks,
IBM Tivoli Netcool Performance Manager Wireline Component January 2012 Document Revision R2E1. Pack Upgrade Guide
IBM Tioli Netcool Performance Manager Wireline Component January 2012 Document Reision R2E1 Pack Upgrade Guide Note Before using this information and the product it supports, read the information in Notices
Software Installation
iseries Software Installation Version 5 SC41-5120-05 iseries Software Installation Version 5 SC41-5120-05 Note Before using this information and the product it supports, be sure to read the information
QLogic 4Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide
QLogic 4Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide The QLogic 4Gb Fibre Channel Expansion Card (CIOv) for BladeCenter enables you to quickly and simply
ThinkServer RD550 and RD650 Operating System Installation Guide
ThinkServer RD550 and RD650 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and
ERserver. iseries. Service tools
ERserer iseries Serice tools ERserer iseries Serice tools Copyright International Business Machines Corporation 2002. All rights resered. US Goernment Users Restricted Rights Use, duplication or disclosure
ThinkServer RS140 Operating System Installation Guide
ThinkServer RS140 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and Support
Integrated Management Module I. User's Guide
Integrated Management Module I User's Guide Integrated Management Module I User's Guide Seenth Edition (Noember 2013) Copyright IBM Corporation 2013. US Goernment Users Restricted Rights Use, duplication
Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide
Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide The Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter enables high-performance connection
Integrated Management Module II. User's Guide
Integrated Management Module II User's Guide Integrated Management Module II User's Guide First Edition (March 2012) Copyright IBM Corporation 2012. US Goernment Users Restricted Rights Use, duplication
Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server
System Storage DS3000 Storage Manager Version 10 Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server System Storage DS3000 Storage Manager Version
Lightweight Directory Access Protocol. BladeCenter Management Module and IBM Remote Supervisor Adapters
Lightweight Directory Access Protocol User s Guide for IBM ERserer BladeCenter Management Module and IBM Remote Superisor Adapters Lightweight Directory Access Protocol User s Guide for IBM ERserer BladeCenter
Installation and Configuration Guide
IBM Tioli Storage Productiity Center Version 5.2 Installation and Configuration Guide SC27-4058-01 IBM Tioli Storage Productiity Center Version 5.2 Installation and Configuration Guide SC27-4058-01 Note:
IBM Directory Server Version 4.1 Installation and Configuration Guide for Multiplatforms
IBM Directory Serer Version 4.1 Installation and Configuration Guide for Multiplatforms IBM Directory Serer Version 4.1 Installation and Configuration Guide for Multiplatforms Note Before using this information
IBM Director 4.20. Systems Management Guide
IBM Director 4.20 Systems Management Guide IBM Director 4.20 Systems Management Guide Note: Before using this information and the product it supports, be sure to read the general information in Appendix
AS/400e. Digital Certificate Management
AS/400e Digital Certificate Management AS/400e Digital Certificate Management ii AS/400e: Digital Certificate Management Contents Part 1. Digital Certificate Management............ 1 Chapter 1. Print
QLogic 8Gb FC Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide
QLogic 8Gb FC Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide The QLogic 8Gb FC Single-port and Dual-port HBA for IBM System x are PCI Express 2.0 x8 8Gb Fibre Channel adapters
IBM Universal Behavior Exchange Toolkit Release 16.1.2 April 8, 2016. User's Guide IBM
IBM Uniersal Behaior Exchange Toolkit Release 16.1.2 April 8, 2016 User's Guide IBM Note Before using this information and the product it supports, read the information in Notices on page 39. This document
Installing the Operating System or Hypervisor
Installing the Operating System or Hypervisor If you purchased E-Series Server Option 1 (E-Series Server without preinstalled operating system or hypervisor), you must install an operating system or hypervisor.
Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers
Technical white paper Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers Table of contents Abstract... 2 Introduction to Red Hat Enterprise Linux 6... 2 New features... 2 Recommended ProLiant
BladeCenter Advanced Management Module BladeCenter T Advanced Management Module. User's Guide
BladeCenter Adanced Management Module BladeCenter T Adanced Management Module User's Guide BladeCenter Adanced Management Module BladeCenter T Adanced Management Module User's Guide Note Before using
IBM WebSphere Application Server Version 7.0
IBM WebSphere Application Server Version 7.0 Centralized Installation Manager for IBM WebSphere Application Server Network Deployment Version 7.0 Note: Before using this information, be sure to read the
Integrated Virtualization Manager ESCALA REFERENCE 86 A1 82FA 01
Integrated Virtualization Manager ESCALA REFERENCE 86 A1 82FA 01 ESCALA Integrated Virtualization Manager Hardware May 2009 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE
IBM License Metric Tool Version 9.0 (includes version 9.0.1, 9.0.1.1 and 9.0.1.2 ) Managing the Software Inventory Guide
IBM License Metric Tool Version 9.0 (includes ersion 9.0.1, 9.0.1.1 and 9.0.1.2 ) Managing the Software Inentory Guide IBM License Metric Tool Version 9.0 (includes ersion 9.0.1, 9.0.1.1 and 9.0.1.2 )
Flex System Chassis Management Module User's Guide (For Type 7893, 8721, and 8724 chassis only)
Flex System Chassis Management Module User's Guide (For Type 7893, 8721, and 8724 chassis only) Note Before using this information and the product it supports, read the general information in Appendix
Tivoli Endpoint Manager for Remote Control Version 8 Release 2. User s Guide
Tivoli Endpoint Manager for Remote Control Version 8 Release 2 User s Guide Tivoli Endpoint Manager for Remote Control Version 8 Release 2 User s Guide Note Before using this information and the product
Password Synchronization for Active Directory Plug-in Installation and Configuration Guide
Tioli Identity Manager Version 5.1 Password Synchronization for Actie Directory Plug-in Installation and Configuration Guide SC23-9622-00 Tioli Identity Manager Version 5.1 Password Synchronization for
PARALLELS SERVER BARE METAL 5.0 README
PARALLELS SERVER BARE METAL 5.0 README 1999-2011 Parallels Holdings, Ltd. and its affiliates. All rights reserved. This document provides the first-priority information on the Parallels Server Bare Metal
Reverse Proxy Scenarios for Single Sign-On
Sterling Secure Proxy Reerse Proxy Scenarios for Single Sign-On Version 3.4 Sterling Secure Proxy Reerse Proxy Scenarios for Single Sign-On Version 3.4 Note Before using this information and the product
IBM SmartCloud Monitoring - Application Insight. User Interface Help SC27-5618-01
IBM SmartCloud Monitoring - Application Insight User Interface Help SC27-5618-01 IBM SmartCloud Monitoring - Application Insight User Interface Help SC27-5618-01 ii IBM SmartCloud Monitoring - Application
ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of June 3, 2009 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
System i and System p. Customer service, support, and troubleshooting
System i and System p Customer service, support, and troubleshooting System i and System p Customer service, support, and troubleshooting Note Before using this information and the product it supports,
How To Set Up An Ops Console On A Pc Or Mac Or Macbook
ERserer iseries iseries Access for Windows Operations Console ERserer iseries iseries Access for Windows Operations Console Copyright International Business Machines Corporation 2002, 2003. All rights
IBM InfoSphere Master Data Management Standard and Advanced Editions Version 11 Release 3. Installation Guide GI13-2658-01
IBM InfoSphere Master Data Management Standard and Adanced Editions Version 11 Release 3 Installation Guide GI13-2658-01 IBM InfoSphere Master Data Management Standard and Adanced Editions Version 11
PARALLELS SERVER 4 BARE METAL README
PARALLELS SERVER 4 BARE METAL README This document provides the first-priority information on Parallels Server 4 Bare Metal and supplements the included documentation. TABLE OF CONTENTS 1 About Parallels
Windows Host Utilities 6.0.2 Installation and Setup Guide
Windows Host Utilities 6.0.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
AS/400e. Networking PPP connections
AS/400e Networking PPP connections AS/400e Networking PPP connections Copyright International Business Machines Corporation 1998, 2000. All rights resered. US Goernment Users Restricted Rights Use, duplication
Tipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2
Tipos de Máquinas X550M2 1. Overview - 7946 x3550 M2 IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized,
HP VMware ESXi 5.0 and Updates Getting Started Guide
HP VMware ESXi 5.0 and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi. HP Part Number: 616896-002 Published: August 2011 Edition: 1 Copyright
Tivoli Integrated Portal Administration and configuration guide. Version 1.0 Tivoli Integrated Portal 2.2
Tioli Integrated Portal Administration and configuration guide Version 1.0 Tioli Integrated Portal 2.2 Tioli Integrated Portal Administration and configuration guide Version 1.0 Tioli Integrated Portal
IBM Tivoli Storage Manager for Linux. Quick Start. Version 5 Release 1 GC23-4692-00
IBM Tioli Storage Manager for Linux Quick Start Version 5 Release 1 GC23-4692-00 IBM Tioli Storage Manager for Linux Quick Start Version 5 Release 1 GC23-4692-00 Note! Before using this information and
IBM. Blueprint and Server Automated Configuration for Linux x86. IBM Tivoli Storage Manager. Version 2.1
IBM Tioli Storage Manager IBM Blueprint and Serer Automated Configuration for Linux x86 Version 2.1 Note: Before you use this information and the product it supports, read the information in Notices on
ZENworks 11 Support Pack 4 Full Disk Encryption Agent Reference. May 2016
ZENworks 11 Support Pack 4 Full Disk Encryption Agent Reference May 2016 Legal Notice For information about legal notices, trademarks, disclaimers, warranties, export and other use restrictions, U.S. Government
Installation and Host Support Guide
IBM System Storage DS Storage Manager Version 10.8 Installation and Host Support Guide GA32-2221-04 Note Before using this information and the product it supports, read the information in Notices on page
v7.1 Technical Specification
v7.1 Technical Specification Copyright 2011 Sage Technologies Limited, publisher of this work. All rights reserved. No part of this documentation may be copied, photocopied, reproduced, translated, microfilmed,
Migrating to ESXi: How To
ILTA Webinar Session Migrating to ESXi: How To Strategies, Procedures & Precautions Server Operations and Security Technology Speaker: Christopher Janoch December 29, 2010 Migrating to ESXi: How To Strategies,
The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000.
Emulex HBA Product Evaluation Evaluation report prepared under contract with Emulex Corporation Introduction Emulex Corporation commissioned Demartek to evaluate its 8 Gbps Fibre Channel host bus adapters
Product Overview Guide
IBM Security Identity Manager Version 6.0 Product Oeriew Guide GC14-7692-01 IBM Security Identity Manager Version 6.0 Product Oeriew Guide GC14-7692-01 Note Before using this information and the product
Business Intelligence Guide
Sterling Call Center and Sterling Store Business Intelligence Guide Release 9.1.0.10 Sterling Call Center and Sterling Store Business Intelligence Guide Release 9.1.0.10 Note Before using this information
IBM Tealeaf CX Version 9 Release 0.2 June 18, 2015. Tealeaf Databases Guide
IBM Tealeaf CX Version 9 Release 0.2 June 18, 2015 Tealeaf Databases Guide Note Before using this information and the product it supports, read the information in Notices on page 111. This edition applies
Tivoli Security Compliance Manager
Tioli Security Compliance Manager Version 5.1 Tioli Risk Manager Adapter Guide Tioli Security Compliance Manager Version 5.1 Tioli Risk Manager Adapter Guide Note Before using this information and the
IBM EMM Reports Version 9 Release 1.1 November 26, 2014. Installation and Configuration Guide
IBM EMM Reports Version 9 Release 1.1 Noember 26, 2014 Installation and Configuration Guide Note Before using this information and the product it supports, read the information in Notices on page 161.
Linux. Installing Linux with the IBM Installation Toolkit for PowerLinux
Linux Installing Linux with the IBM Installation Toolkit for PowerLinux Linux Installing Linux with the IBM Installation Toolkit for PowerLinux Note Before using this information and the product it supports,
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting
Windows Host Utilities 6.0 Installation and Setup Guide
Windows Host Utilities 6.0 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP
IBM Client Security Solutions. Client Security Software Version 5.3 Installation Guide
IBM Client Security Solutions Client Security Software Version 5.3 Installation Guide IBM Client Security Solutions Client Security Software Version 5.3 Installation Guide First Edition (May 2004) Before
Yosemite Server Backup Installation Guide
Yosemite Server Backup Installation Guide Part number: First edition: October, 2010 Legal and notice information Copyright 2004, 2012 Barracuda Networks, Inc. Under copyright laws, the contents of this
IBM Unica Marketing Operations and Campaign Version 8 Release 6 May 25, 2012. Integration Guide
IBM Unica Marketing Operations and Campaign Version 8 Release 6 May 25, 2012 Integration Guide Note Before using this information and the product it supports, read the information in Notices on page 51.
MegaRAID SAS Device Driver Installation
MegaRAID SAS Device Driver Installation User Guide 80-00163-01, Rev. G Revision History Version and Date Description of Changes 80-00163-01 Rev. G, Added the Microsoft Windows 8 operating system (OS),
IBM Unica Marketing Platform Version 8 Release 5 June 1, 2012. Administrator's Guide
IBM Unica Marketing Platform Version 8 Release 5 June 1, 2012 Administrator's Guide Note Before using this information and the product it supports, read the information in Notices on page 449. This edition
McAfee Firewall Enterprise
Hardware Guide Revision C McAfee Firewall Enterprise S1104, S2008, S3008 The McAfee Firewall Enterprise Hardware Product Guide describes the features and capabilities of appliance models S1104, S2008,
IBM Informix Dynamic Server Installation Guide for UNIX, Linux, and Mac OS X
IBM Informix Version 11.50 IBM Informix Dynamic Serer Installation Guide for UNIX, Linux, and Mac OS X GC27-3620-00 IBM Informix Version 11.50 IBM Informix Dynamic Serer Installation Guide for UNIX, Linux,
IBM Maximo for Aviation MRO Version 7 Release 6. Guide
IBM Maximo for Aiation MRO Version 7 Release 6 Guide Note Before using this information and the product it supports, read the information in Notices on page 185. This edition applies to ersion 7, release
Planning an Installation
IBM Tioli Composite Application Manager for Application Diagnostics Version 7.1.0.2 Planning an Installation GC27-2827-00 IBM Tioli Composite Application Manager for Application Diagnostics Version 7.1.0.2
Prerequisites and Configuration Guide
Prerequisites and Configuration Guide Informatica Support Console (Version 2.0) Table of Contents Chapter 1: Overview.................................................... 2 Chapter 2: Minimum System Requirements.................................
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of September 17, 2007 Please review this file for important information about issues and erratas that were discovered after completion of the standard product
IBM License Metric Tool Version 7.2.2. Installing with embedded WebSphere Application Server
IBM License Metric Tool Version 7.2.2 Installing with embedded WebSphere Application Server IBM License Metric Tool Version 7.2.2 Installing with embedded WebSphere Application Server Installation Guide
Smart Server Manager v1.2 Best Practices. Smart Server Manager v1.2 Best Practices Guide
Smart Server Manager v1.2 Best Practices Guide Acer EPBU, July 2012 1 Contents About this guide 3 Smart Server Manager overview 4 What s new to Smart Server Manager 5 Required hardware and software 6 Network
IBM Spectrum Control Base Edition Version 2.1.1. Release Notes
Version 2.1.1 Release Notes First (June 2015) This edition applies to ersion 2.1.1 of the software package. Newer document editions may be issued for the same product ersion in order to add missing information
Network Shutdown Module V3 Extension of the User Manual for IBM BladeCenter architecture
Network Shutdown Module V3 Extension of the User Manual for IBM BladeCenter architecture Network Shutdown Module V3 Extension for IBM BladeCenter Architecture- 34 022 272 XU / AC Contents 1 Introduction...3
Operating System Installation Guide
Operating System Installation Guide This guide provides instructions on the following: Installing the Windows Server 2008 operating systems on page 1 Installing the Windows Small Business Server 2011 operating
BladeCenter Advanced Management Module BladeCenter T Advanced Management Module. Command-Line Interface Reference Guide
BladeCenter Adanced Management Module BladeCenter T Adanced Management Module Command-Line Interface Reference Guide BladeCenter Adanced Management Module BladeCenter T Adanced Management Module Command-Line
Remote Control 5.1.2. Tivoli Endpoint Manager - TRC User's Guide
Tivoli Remote Control 5.1.2 Tivoli Endpoint Manager - TRC User's Guide Tivoli Remote Control 5.1.2 Tivoli Endpoint Manager - TRC User's Guide Note Before using this information and the product it supports,
Data Protection for Microsoft Exchange Server Installation and User's Guide
IBM Tioli Storage Manager for Mail Version 6.4 Data Protection for Microsoft Exchange Serer Installation and User's Guide GC27-4009-01 IBM Tioli Storage Manager for Mail Version 6.4 Data Protection for
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive
Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting
HP BladeSystem ProLiant Firmware Management Best Practices
HP BladeSystem ProLiant Firmware Management Best Practices Implementer Guide Table of contents Introduction... 5 Firmware updates... 5 HP BladeSystem... 5 Overview... 5 Quickstart... 6 Generic BladeSystem
Broadcom NetXtreme Gigabit Ethernet Adapters IBM Redbooks Product Guide
Broadcom NetXtreme Gigabit Ethernet Adapters IBM Redbooks Product Guide The Broadcom NetXtreme Gigabit Ethernet Adapters are a family of high performance PCI Express adapters. With five adapters to choose
IBM Unica Campaign Version 8 Release 6 May 25, 2012. Data Migration Guide
IBM Unica Campaign Version 8 Release 6 May 25, 2012 Data Migration Guide Note Before using this information and the product it supports, read the information in Notices on page 49. This edition applies
RDP 6.0.0 Release Notes And Support
RDP 6.0.0 Release Notes And Support Deployment Server Prerequisites Feature List Major Changes Known Issues Supported Operating Systems Supported ProLiant Targets Supported Integrity Targets Supported
LOCKSS on LINUX. CentOS6 Installation Manual 08/22/2013
LOCKSS on LINUX CentOS6 Installation Manual 08/22/2013 1 Table of Contents Overview... 3 LOCKSS Hardware... 5 Installation Checklist... 6 BIOS Settings... 9 Installation... 10 Firewall Configuration...
IBM Tivoli Storage Manager for Databases Version 7.1. Data Protection for Microsoft SQL Server Installation and User's Guide
IBM Tioli Storage Manager for Databases Version 7.1 Data Protection for Microsoft SQL Serer Installation and User's Guide IBM Tioli Storage Manager for Databases Version 7.1 Data Protection for Microsoft
IT Business Management System Requirements Guide
IT Business Management System Requirements Guide IT Business Management 8.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced
MegaRAID SAS Device Driver Installation
MegaRAID SAS Device Driver Installation User Guide 80-00163-01, Rev. K 80-00163-01K Revision History Version and Date Description of Changes 80-00163-01 Rev. K, Updated the supported operating system versions.
VERITAS Backup Exec TM 10.0 for Windows Servers
VERITAS Backup Exec TM 10.0 for Windows Servers Quick Installation Guide N134418 July 2004 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software
