IV-S30SP. Model name. Instruction Manual. Version 3.0 Produced in Sep SParameter setting support software for the IV series
|
|
|
- Stephen Evans
- 10 years ago
- Views:
Transcription
1 Version 3.0 Produced in Sep SParameter setting support software for the IV series Model name IV-S30SP Instruction Manual <Applied models> - IV-S30 - IV-S31M/S32M/S33M IV-S31MX/S32MX/S33MX - IV-S30J - IV-C35M - IV-S20
2 Thank you for purchasing the IV-S30SP, which is parameter setting support software for the IV series. Read this manual thoroughly to understand the features and operation of this software completely. Keep this manual for future reference. We are confident that this manual will be helpful whenever you encounter a problem. Store this user s manual in a safe place. We are confident that the manual will be helpful whenever you encounter a problem. In addition to this manual, there are other IV-S30/C35M/S20 manuals as follows. Read them in conjunction with this manual. - IV-S30 (IV-S31M/S32M/S33M) User s Manual (Introduction and hardware) User s Manual (Function and operation) - IV-S30 (IV-S31MX/S32MX/S33MX) User s Manual (Introduction and hardware) User s Manual (Function and operation) - IV-S30 (IV-S30J) User s Manual (Introduction and hardware) User s Manual (Function and operation) - IV-C35M User s Manual (Introduction and hardware) User s Manual (Function and operation) - IV-S20 Introduction Manual User s Manual Software version This manual describes version 3.06 of the IV-S30SP system software. The details of the upgrade from version 2.20 are as follows. Added functions in version 3.06 (compared with version 2.20) Item Applicable controller Memory card Additional function Also applicable to IV-S31MX/S32MX/S33MX, IV-S30J, and IV-C35M. If IV-C35M is used, this application software can read, save, and delete data from a flash memory card. Reference page Page 5-2 and others Page 11-4 Note - This manual is written with the utmost care. If you note something wrong or unclear, please contact the sales shop or service company. - No part of this manual may be reproduced in any form without written permission from SHARP corporation. - The contents of this manual are subject to change without prior notice. - We are not liable for any damage, lost profits or charges made by third parties which may be caused by using this software.
3 Operating environment This software runs on any computer, which is equipped with the following operating environment. Item Model CPU Operating system Memory Hard disk Display CD-ROM drive RS-232C port Mouse Printer USB port Specification IBM PC/AT or compatible machines Pentium 90 MHz minimum (recommend Pentium 133 MHz or better) Microsoft Windows Me, Microsoft Windows 2000 Microsoft Windows NT4.0, Microsoft Windows 95/98 32 M-bytes minimum (recommend 48 M-bytes or more) 30 M-bytes or more free space SVGA or more (Resolution: 800 x 600 pixels, 256 color or more) Recommended color monitor display: High color (16 bits) or better Needed to install this software One port or more A mouse or pointing device compatible with the Windows95/98/NT4.0 environment. A printer compatible with the Me/2000/NT/98/95 environment. One port recommended (only Windows Me/2000/98 supports the USB interface) Windows is a registered trade mark of Microsoft Corporation, USA. Pentium is a registered trade mark of Intel Corporation, USA.
4 Preface Setup Version for the IV-S30/C35M Chapter 1: Menu Organization Chapter 2: Chapter 3: Chapter 4: Chapter 5: Chapter 6: Chapter 7: Chapter 8: Chapter 9: Optional Settings Parameter settings Reading/Writing Parameters and Images File operations Document Creation Data Collection User Menu Editor Command Test Chapter 10: Upgrade Version Chapter 11: Additional Description Version for the IV-S20 Chapter 1: Menu Organization Chapter 2: Set Communication Chapter 3: Setting Object Type Conditions Chapter 4: Document Creation Chapter 5: Data Collection Chapter 6: Reading/Writing Parameters and Images Chapter 7: Command Test Chapter 8: Upgrade Version Chapter 9: Additional Description Error code
5 Table of contents Preface... Pref-1 to 3 [1] Features Pref-1 [2] Operating environment Pref-2 [3] System configuration Pref-2 [4] Product components Pref-3 [5] User file Pref-3 Setup... Setup-1 to 8 [1] Installation of the IV-S30SP Setup-1 [2] Setting the Windows environment Setup-5 [3] Installation of a USB driver (version for the IV-S30/C35M) Setup-6 [Version for the IV-S30/C35M] Chapter 1: Menu Organization to 1-4 Chapter 2: Optional Settings to Specify the communication conditions Transfer conditions Upgrade conditions 2-4 Chapter 3: Parameter settings to Setting the measurement conditions Setting the evaluation conditions Setting the numerical calculation conditions Setting the output conditions Setting the distance and angle conditions 3-13 Chapter 4: Reading/Writing Parameters and Images to Read Write Verify Initialization Self diagnosis 4-5 Chapter 5: File Operations to 5-2 Chapter 6: Document Creation to Document creation (Project file) Document creation (IV-S30/C35M parameter loading) 6-3 Chapter 7: Data Collection (Measurement result/ng image) to7-6 Contents-1
6 Chapter 8: User Menu Editor (IV-S31M/S32M/S33M) to How to start the editor Read Write Initialize the user menus Editing Titles Editing character strings Menu editing Create a user menu Create a new MAIN OPS MENU screen File operation 8-9 Chapter 9: Command Test to 9-3 Chapter 10: Upgrade Version to 10-2 Chapter 11: Additional Descriptions to 11-4 [1] Print 11-1 [2] Changing the message display color 11-1 [3] Zoom 11-2 [4] Changing the image brightness 11-2 [5] SMS Web page 11-3 [6] Memory card (IV-C35M) 11-4 [Version for the IV-S20] Chapter 1: Menu Organization to1-5 Chapter 2: Set Communication Chapter 3: Setting Object Type Conditions to Setting the measurement conditions Setting the evaluation conditions Setting the numerical calculation conditions Setting the output condition Operation example (positional deviation measurement) 3-11 Chapter 4: Document Creation to Document creation (IV-S20 parameter) Document creation (file data) 4-3 Chapter 5: Data Collection to 5-4 Chapter 6: Reading/Writing Parameters and Images to Saving setting parameters Verifying setting parameters Loading setting parameters 6-4 Contents-2
7 6-4 Reading/writing images 6-5 [1] Reading images (display images and messages) 6-5 [2] Writing images (load images) 6-7 Chapter 7: Command Test to 7-3 Chapter 8: Upgrade Version to 8-2 Chapter 9: Additional Descriptions to 9-2 [1] Copy to the clipboard 9-1 [2] Changing the message display color 9-1 [3] Changing the image brightness 9-2 Error code... E-1 Contents-3
8 Preface Preface Pref. This software (IV-S30SP) is a parameter setting support software used to specify the parameters for the compact image sensor camera IV-S30/C35M/S20. It runs on Windows Me/2000/NT4.0/98/95 platforms, and allows users to specify data, and manage and analyze inspection results, using a personal computer. [1] Features - Its offline setting function allows you to specify and change object type conditions without halting a production line. - Its automatic document creation function allows you to manage and save the parameter settings. - Its measurement data collection function can transmit measurement results from the IV-S30/C35M/S20 to a personal computer. - Its parameter data upload/download function enables you to send samples via for evaluation of sample measurements, and to copy data easily to other IV-S30/C35M/S20 controllers. - Its image data output function can print a captured image using a personal computer. - The IV-S30/C35M/S20 system software upgrade function allows you to upgrade the system functions and resolve problems easily. - The menu customization function allows you to customize the operation screens (user menu editor). - Use of the USB interface increases the data transfer speed dramatically (Windows Me/2000/98 only on the IV-S30/C35M). - There are two versions of the IV-S30SP program: one for the IV-S30/C35M and the other for the IV-S20. The table below describes the differences. Function comparison between the IV-S30/C35M and IV-S20 program versions] Function IV-S30/C35M IV-S20 Parameter setting function O O - Object type condition O O - Global condition O X - Reference image O O Load/save parameters O O Load/save display image and message O O Document creation function O O Data collection function O O User menu editor function * 1 X Command test function O O Upgrade function O O Print O O Message color change O O Zoom O X Change image brightness O O Link to SMS Web page O X Memory card * 2 X * 1: The user menu editing function can be used when any IV-S31M/S32M/S33M is used as the controller. * 2: The memory card can only be used when the IV-C35M is used as the controller. Note In this manual, the term "IV-S30/C35M" refers to the following controller models. Model IV-S30/C35M name IV-S30 IV-C35M Controller IV-S31M/S32M/S33M IV-S31MX/S32MX/S33MX IV-S30J IV-C35M Pref-1
9 Preface Pref. [2] Operating environment This software runs on any computer, which is equipped with the following operating environment. Item Model CPU Operating system Memory Hard disk Display CD-ROM drive RS-232C port Mouse Printer USB port Specification IBM PC/AT or compatible machines Pentium 90 MHz minimum (recommend Pentium 133 MHz or better) Microsoft Windows Me, Microsoft Windows 2000 Microsoft Windows NT4.0, Microsoft Windows 95/98 32 M-bytes minimum (recommend 48 M-bytes or more) 30 M-bytes or more free space SVGA or more (Resolution: 800 x 600 pixels, 256 color or more) Recommended color monitor display: High color (16 bits) or better Needed to install this software One port or more A mouse or pointing device compatible with the Windows95/98/NT4.0 environment. A printer compatible with the Me/2000/NT/98/95 environment. One port recommended (only Windows Me/2000/98 supports the USB interface) Windows is a registered trademark of Microsoft Corporation, USA. Pentium is a registered trademark of Intel Corporation, USA. [3] System configuration System connections on the IV-S30(except IV-S30J)/C35M Communication connector (USB) Communication connector (RS232C/RS422) INPUT X0 X1 X2 X3 X4 X5 X6 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 READY COM VIDEO CAMERA1 CAMERA2 OUTPUT X7 USB RS232C/RS422 COM 24V 0V IV-S3 M POWER REMOTE IV-S30 main housing (Side view) *1 RS-232C communication cable Controller: IV-S33MX etc. (Top view) *1 USB cable Personal computer IBM PC/AT (or compatible machines) This software (IV-S30SP) *1: A USB cable and an RS-232C communication cable are accessories that come with this software package. For details about the wiring, see section "Connection with personal computer" in the user s manual of each controller (Introduction and Hardware). Pref-2
10 Preface - System connections on the IV-S20, IV-S30J INPUT X0 X1 X2 X3 X4 X5 X6 C( ) 24V 0V Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 BUSY C( ) OUTPUT POWER IV-S20 POWER IV-S20 main housing, IV-S30J (Top view) Pref. VIDEO CAMERA1 CAMERA2 RS232C/RS422 REMOTE IV-S20 main housing, IV-S30J (Side view) Communication connector (RS232C/RS422) *2 RS-232C communication cable Personal computer IBM PC/AT (or compatible ma- This software (IV-S30P) *2 An RS-232C communication cable is an accessory that comes with this software. For details about the wiring, see section "Connection with personal computer" in the IV-S20 user s manual. [4] Product components One CD-ROM One Instruction manual One RS-232C communication cable (1.5 m) [Connector pin D-sub male (IV-S30/S20 side) + 9pin D-sub female (PC side)] One USB cable (3 m) [5] User file Shown below are the user file types, which can be read and written using this software. Project Display Command Classification file (IV-S30/C35M parameters) image test IV-S30/C35M/S20 Document/data Object Global Reference system sofware correction type setting condition condition image Extension apm bmp tst mot csv msr prm bmp Pref-3
11 Setup Setup The installation process that places a program on a computer and makes it ready for use is referred to as the "Setup." This chapter describes the setup procedure. This software runs on the Windows Me/2000/NT/98/95. The descriptions in this chapter use a Windows98 installation for the example. Note: Before starting the installation, disable any virus check programs in your computer. Set [1] Installation of the IV-S30SP 1. Start up the Windows98, and place the IV-S30SP CD- ROM on the CD-ROM drive. Note: Do not put any labels on the CD-ROM. 2. Double-clicks the CD-ROM drive icon on the Windows desktop. You will find folders for both the IV-S20 and IV-S30/C35M on the CD-ROM (see below). Face the CD-ROM label side up. Refers to the IV-S20 version in this manual Refers to the IV-S30/C35M version in this manual - When using the IV-S30/C35M Open the [IV-S30] from [IVS30SP] folder on the CD-ROM. Then double-click on "setup.exe." - Go to step 3. - When using the IV-S20 (English) Open the [IV-S20]-[English] from [IVS30SP] folder on the CD-ROM. Then open the [ENGLISH] folder. Double-click on "setup.exe." - Go to step 4 3. Select the OS type that you have and specify Japanese or English. The descriptions below explain the use of the software on the IV-S30/C35M. (When the upgrade software for the IV-S20 is installed, the term "IV-S30SP" in the messages will change to "IV-S20SP.") 4. The setup program will startup and prepare the setup wizard. After the setup preparation is complete, the dialog box shown on the right will appear. Setup-1
12 Setup 5. Click the "Next" button. The following dialog box will appear. Set 6. When you do not need to change the folder (directory) where you want to install the program, simply click the "Next" button to continue the installation. To change directory, click on the "Browse..." button. The "Choose Folder" dialog box will appear. Select the drive and directory, and click on the "OK" button. Then click on the "Next" button to continue. Setup-2
13 Setup 7. By clicking on the "Next" button, the "Select Program Folder" dialog box will appear. Set 8. When you do not want to change the program folder, simply click on the "Next" button to continue the installation. To change the folder, enter a new folder name, or select a folder from the existing folder list. Then click on the "Next" button to continue installing the program. After the setup is complete, the following dialog box will appear. 9. Click on the "Finish" button to return to the initial setup screen. Setup-3
14 Setup 10. To start this program, bring up the start menu in Windows98, and then select "Programs" - "Sms" - and "IVS30SP" in that order. Set The program will start and the following screen will appear. - Screen for the IV-S20 (See page Setup-1.) 11. To quit this program, select the "File" - "Exit" item from the menu bar. - Screen for the IV-S20 (See page Setup-1.) - The confirmation dialog box will appear. Click on the "Yes" button to stop this program. Setup-4
15 Setup You can also stop the program by clicking on the " " button in the upper right corner of the window. Click here Set - The confirmation dialog box will appear. Click on the "Yes" button. [2] Setting the Windows environment 1. From the scroll bar menu, select "Settings" and then "Control Panel." 2. Open the "Display Properties" menu and click on the "Settings" Tab. Then, set the number of colors in the "Color palette" and the font size in "Font size." Please select "Small Fonts." Please select "256 Color." Setup-5
16 Setup [3] Installation of a USB driver (version for the IV-S30/C35M) 1. Turn ON the power to the controller (IV-S33MX etc., except IV-S30J). Set 2. After turning ON the power, connect the personal computer to the controller using the USB cable. The [Add New Hardware Wizard] dialog box will appear, and it will display an "Unknown Device" message. Setup-6
17 Setup 3. Click on the [Next] button. The display will change to the screen for selecting a search method. Select "Search for the best driver for the device. [Recommended]," and click on the [Next] button. Set 4. A USB device driver is stored on the IV-S30SP CD-ROM. If the CD-ROM drive in your personal computer is labeled E, enter "E:\driver" for the search location. Then click on the [Next] button. 5. "ivs30usb Device" will appear. Click on the [Complete] button to finish the setting. Setup-7
18 Setup Set 6. To make sure that the setting is completed correctly, select [System] from [Control Panel] and examine the device tree in the Device Manager. If the "Ivs30usb Device" icon is displayed as shown in the figure below, installation of the device driver is complete. Setup-8
19 Version for the IV-S30/C35M
20 Chapter 1: Menu Organization Chapter 1: Menu Organization After starting this software (for the IV-S30/C35M), the screen shown below will appear. The menu organization on the menu bar is also shown below. The following menus (1) to (7) correspond to the items on the next page. IV-S30/C35M 1 (1) (2) (3) (4) (5) (6) (7) - This screen will be displayed when this software (for IV-S30/C35M) is started. 1-1
21 Chapter 1: Menu Organization IV-S30/C35M 1 (1) File (Description) New Ctrl + N Create a new file. Open Ctrl+O Open an existing image file. (*.bmp/*.msr/*.prm) Save display image Ctrl+S Save only the currently displayed image. Open project (W) Open a project file, such as the controller parameters. Save project (V) Save a project file, such as the controller parameters. Save As project (E) Save a project file, such as the controller parameters using a new file name. Close project (K) Close a project file, such as the controller parameters. Properties (I) Display the current project and model names (IV-S33MX etc.). Page setup Specify the pages to print. Print Ctrl+P Print Exit Quit the IV-S30SP. (2) Edit (Description) Cut Ctrl + X Copy the image displayed on the IV-S30SP to the clipboard and delete it after it is pasted elsewhere. Copy Ctrl + C Copy the image displayed on the IV-S30SP to the clipboard. Paste Ctrl + V Paste the IV-S30SP image currently being held on the clipboard. Add Delete Add an object type to the object type conditions. Delete the image currently displayed on the IV-S30SP. 1-2
22 Chapter 1: Menu Organization (3) View (display) Toolbars (Description) Standard Select whether or not to display the standard tool bar. Display image Select whether or not to display the tool bar used for displaying an image. Status Bar (S) Select whether or not to display the status bar. Display image monitor Select whether or not to display the image window for monitoring. Parameter List Select whether or not to display the parameter list box. Zoom In Zoom in closer to an image. Zoom Out Zoom back away from an image. Zoom Magnification Rate Select an image size: 25, 50, 75, or 100% of normal. 100%, 75%, 50%, 25% Display image Brightness Level Change the image brightness between standard and one-half of normal. IV-S30/C35M 1 Standard, 1/2 Message Color (C) Change the message display color to the specified color. Black, Blue, Green, Cyan, Red, Magenta, Yellow, White (4) IVS30 communication IVS30 data transfer (Description) Write Send a set of parameters or an image from the PC to the controller. Read Read a set of parameters or an image from the controller. Verify Verify that the parameters or image in the PC is the same as that in the controller. Initialize Initialize the parameters or images in the controller. Self Test Have the controller check its own parameters and image conditions. Version grade Upgrade the system software in the controller. Option Specify the communication, IV data transfer, and upgrade conditions. 1-3
23 Chapter 1: Menu Organization IV-S30/C35M 1 (5) Tools Command Test Data collection Create document User menu editor (IV-S31M/S32M/S33M) Memory card (IV-C35M) (6) Window Cascade display Tile Vertically Tile Horizontally (Description) Test the communication between the controller and a personal computer. Send the measurement execution data from the controller to a personal computer and total the data. Create a document using the current IV parameter details. Create or modify IV menus and messages. Reads, saves, and deletes data from a flash memory card. (Description) Overlap the open windows. Display the open windows in a vertical layout. Display the open windows in a horizontal layout. (7) Help Contents Contents and Index SMS Web page About IV-S30SP (Description) Display the table of contents for the Help files. Display the help menu search topic screen. Look at the SMS web site. Display the version information for the IV-S30SP program. 1-4
24 Chapter 2: Optional Settings Chapter 2: Optional Settings When you communicate between the personal computer and the IV-S30/C35M, you must specify the communication conditions for IV-S30/C35M data transfers, and software upgrades. - For details about setting the specific controller model, see page Specify the communication conditions Click on the "Option" in the "IVS30 communication" menu. IV-S30/C35M 2 Click here - The "Option" dialog box will appear. Ë Serial communication Select "Serial" for the "COMM method" and specify the other communication conditions. Note: Make sure to specify the same communication conditions as previously specified in the [COMM. SET] item on the IV-S30/C35M s [SYSTEM COND] menu. Click here 2-1
25 Chapter 2: Optional Settings Ë USB communication Select "USB" for the "COMM method" and specify the other communication conditions. IV-S30/C35M 2 Click here USB data transfer - Only: Only transfer data to the IV-S30/C35M that have been specified in the "Station" assignments. - All: Transfer data to all of the IV-S30/C35M controllers that are connected to the USB cables. 2-2
26 Chapter 2: Optional Settings 2-2 Transfer conditions Select "IV-S30/C35M transfer conditions" from the "Option" dialog box and specify the other transfer conditions in the window. IV-S30/C35M 2 (When the IV-C35M is specified as the controller model to use) [Parameter] = All parameters specified in the IV-S30/C35M Object type conditions: The conditions specified for each object type (measurement conditions, etc.) Global conditions: The shared conditions which are set and applied to all object types (system conditions, etc.) Reference image: Any reference image registered in the IV-S30/C35M Title & Character: Transfers all the titles and character strings used with the IV-S30/C35M (Since it takes a long time to transfer the data, we recommend that you should not read it out if you did not changes the titles or character strings.) Wizard sample (except for the IV-S31M/S32M/S33M) : Samples that were registered using the set wizard function. [Gray scale image] = 256 intensity levels (When the IV-C35M is used, this item will read: [Color/ gray image].) Capture: Store the image displayed on the MAIN OPS MENU. Pre-process:An image processed by making shading corrections and binary image masking. Rotated: Change the base angle on a captured image. Work area: The portion of an image used for making measurements. * Select either "Capture all images" or "Capture partial image." [Binary image] Pattern: Displays a frame around the search area of the image to be measured on the MAIN OPS MENU. Character: Characters displayed on the IV-S30/C35M screen. Binary image: An image that has been captured and processed by binary conversion. [NG images] = Images captured by the IV-S30/C35M that fail some measurement criteria. 2-3
27 Chapter 2: Optional Settings IV-S30/C35M Upgrade conditions Select "Software upgrade conditions" in the "Option" dialog box and specify the other upgrade conditions in the window. [Upgrade version type] No initialization: Do not initialize the IV-S30/C35M. All initialization: Initialize the IV-S30/C35M. [Program used to send data] Boot: IV-S30/C35M boot program System: IV-S30/C35M system program 2-4
28 Chapter 3: Parameter Settings Chapter 3: Parameter settings Set object type conditions (Measurement conditions, Evaluation conditions, Numerical conditions, and output conditions). - You can set and change the conditions offline. (You can set and change conditions without stopping the production line while it is operating.) - For details about setting the specific controller model, see page 5-2. Adding a new object type 1. Click the [Object type conditions] tag on the parameter list. Then click the right mouse button on the [New object type]. Next, click on [Add]. (You may double click the left mouse button instead of clicking the right mouse button.) IV-S30/C35M 3 Click here - The [Add] dialog box will appear. 2. Select an object type number to add and click on the [OK] button. - Then new object number will be added. 3-1
29 Chapter 3: Parameter Settings Setting the measurement conditions: When measurement 0 and camera 1 (position deviation measurement) is selected. 1. Double click on [Measure 0 Camera 1 Conditions]. IV-S30/C35M 3 Double-click here - The "Measure 0 Camera 1 Conditions" dialog box will open. Click on the "Measure position deviation" item. Click here 2. Click on "Measure position deviation" and then click on the [Close] button. - "Measure position deviation" will be added to the [Measure 0 Camera 1 Conditions] menu. 3. Double click on the "Measure conditions" item on the "Measure position deviation" menu. - See the next page. Double-click here 3-2
30 Chapter 3: Parameter Settings - The "Measure position deviation" setting screen will appear. IV-S30/C35M 3 3-3
31 Chapter 3: Parameter Settings 3-1 Setting the measurement conditions Select the "Measure position deviation" tab and double-click on the "Measure conditions" item on the parameter list. The measurement condition screen will appear. IV-S30/C35M 3 Operation details: When setting up the positional deviation measurement (2-point search) Click on the """ button to display the registration condition items on the "Measure position deviation" setting screen(previous page). Then click on the "2P search" item. Click here - The measurement condition screen for the "2P search" will appear. For details about the settings, see the "IV-S30/C35M user s manual." 3-4
32 Chapter 3: Parameter Settings 3-2 Setting the evaluation conditions Select the "Object type condition" tab and double-click on the "Evaluation conditions" item on the parameter list. The evaluation condition screen will appear. Operation details: When setting up the positional deviation measurement (2-point search) Double-click on the "Evaluation conditions" menu on the parameter list. IV-S30/C35M 3 Double-click here - The evaluation condition screen for a 2-point search will appear. The registration number setting. MODEL 0 items to set. Angular deviation items to set. MODEL 1 items to set. For details about the settings, see the "IV-S30/C35M user s manual, Function and Operation." 3-5
33 Chapter 3: Parameter Settings 3-3 Setting the numerical calculation conditions Select the "Object type conditions" tab and double-click on the "Numeric calculation conditions" item on the parameter list. The numerical calculation screen will appear. IV-S30/C35M 3 Operation details: When setting up the positional deviation measurement Double-click on the "Numeric calculation conditions" menu on the parameter list. Double-click here - The "Numeric calculation conditions" screen for measuring positional deviation will appear. - Enter a calculation result number and click on "Yes" in the "Register" item. Then, you can specify each setting individually (type, formula, evaluation, and output). (See the next page.) 3-6
34 Chapter 3: Parameter Settings Click on each of the individual setting sections 1 to 5 below, on the numerical calculation setting table. The details for each setting will appear. 1 Object type setting details 2 Setting details for formula 1-1 (When the type is the X ad Y coordinates, x and y deviations, degree of match M, or angle B) When angle B is selected, the model item is not displayed. IV-S30/C35M 3 2 Setting details for formula 1-2 (When the type is a numerical calculation NC) 2 Setting details for formula 1-3 (When the type is a constant C) 3 Setting details for formula 2 4 Setting details for upper & lower limits 5 Setting details for output For details about these settings, see the section describing the numerical calculation in the "IV-S30/C35M user s manual (Function and Operation)." [Example of settings] 3-7
35 Chapter 3: Parameter Settings Described below is the process used to set the calculation result N0 for the setting example shown on the previous page. (1) Setting the object type 1. Enter "0" for the calculation result number and click on "Yes" in the "Register" dialog box. IV-S30/C35M 3 2. Click on "[X] coordinate." (2) Setting the formula 1. Enter "0" for the registration number and model number, and click on the "Input" button. - The setting details for the formula will appear. 2. Click on the "+" button. - The "+" symbol will be shown on the cell to the right of "00X0." 3. Repeat steps 1 and 2 to enter more formula steps. Continued on the following page 3-8
36 Chapter 3: Parameter Settings From the previous page (3) Setting the upper & lower limits Specify the upper limit for evaluating the output. 1. Click inside the upper limit box for the upper limit. - The current value will be highlighted. 2. Type in the number "410." Click here IV-S30/C35M 3 (Reference) You can also set the upper & lower limits by clicking on the '/" buttons. Click here (4) Set the output. Specify the upper limit for evaluating the output. 1. Click on "Y." 2. Click on "No." Click here Click here 3-9
37 Chapter 3: Parameter Settings 3-4 Setting the output conditions Select the "object type conditions" tab and double-click on the "Output conditions" item on the parameter list. The output conditions screen will appear. IV-S30/C35M 3 Operation details: When setting up the positional deviation measurement Double-click on the "Output conditions" menu on the parameter list. Double-click here - The "Output conditions" screen for measuring positional deviation will appear. Input signal items to set Logical symbol items to set Output signal items to set - Select the page number, and click on the "Yes" item. Then you can specify each setting individually. For details about these setting, see the "IV-S30/C35M user's manual, Function and Operation: PC Function." 3-10
38 Chapter 3: Parameter Settings [Example of settings] Described below is the process used to create the example above. 1. Enter "0" for the page number, and click on "Yes" in the "Register" item. Click here 2. Click on column 0 on the "INPUT 0" line. IV-S30/C35M 3 Click 3. Click on "Degree of match M" as the parameter you want to change. `(See reference below) Click on the [ ] item in the "LOGICAL SYMBOL." area. - The selected input signal and logical symbol will be shown. (Reference) Enter the registration number and the model number (0 or 1) by clicking inside the box or on the '/" arrows (see above `). 5. To create the input section, click on the desired cell, logical symbol, and objective parameter repeatedly, the same as in steps 1 to 4 above. (The cursor will automatically move to the right of the specified column.) Click here 6. Click the output column on the "INPUT0" line
39 Chapter 3: Parameter Settings 7. Specify the output number for the output signal, and the click on the "Input" (enter) button. `2 See reference below `1 IV-S30/C35M 3 Click here - The output signal and the auxiliary relay C000 will be shown in the table. (Reference) - Set the auxiliary relay number (0 to 127) by entering a number of by clicking on the '/" arrows (`1) on the auxiliary relay box, or click inside of the relay number window (`2) to highlight, then enter the number directly. 3-12
40 Chapter 3: Parameter Settings 3-5 Setting the distance and angle conditions Select the "Object type conditions" tag and double-click on the "Distance and angle conditions" item on the parameter list. The distance and angle conditions screen will appear. Operation details: When setting the positional deviation measurement 1. Double-click on the "Distance and angle conditions" menu on the parameter list. IV-S30/C35M 3 Double-click here - The "Distance and angle conditions" screen for measuring positional deviation will appear. 3-13
41 Chapter 3: Parameter Settings 2. Specify the auxiliary conditions in the "Distance and angle conditions" dialog box. IV-S30/C35M 3 3. Specify the other conditions. 3-14
42 Chapter 4: Reading/Writing Parameters and Images Chapter 4: Reading/Writing Parameters and Images You can save the parameter settings and images (display images, messages, patterns) stored in an IV-S30/ C35M controller using a personal computer. Parameter settings can also be downloaded into an IV-S30/C35M. - For details about setting the specific controller model, see page Read Reads the parameter settings and images stored in the IV-S30/C35M to a personal computer. 1. Select the "Read" item using the following menu sequence. "IVS30 communication" "IVS30 data transfer" "Read" IV-S30/C35M 4 Click here - The dialog box for the "Read" session will appear. 2. Click on the "Start" button to start the data transfer. - If you want to specify or modify the transfer or communication conditions, click on the "Option" button. (To send the parameters and gray scale images, select the MAIN OPS MENU screen on the IV-S30/ C35M.) - [Chapter 2: Optional settings] 3. After the transfer is complete, the "Data transfer complete" message box will appear. - To end the operation, click on the "OK" button. 4-1
43 Chapter 4: Reading and Writing Parameters and Images 4-2 Write Write the parameter settings and images stored into a personal computer to the IV-S30/C35M. 1. Select the "Write" item using the following menu sequence. "IVS30 communication" "IVS30 data transfer" "Write" IV-S30/C35M 4 - The dialog box for the "Write" session will appear. Click here 2. Click on the "Start" button to start the data transfer. - If you want to specify or modify the transfer or communication conditions, click on the "Option" button. - [Chapter 2: Optional settings] 3. After the transfer is complete, the "Data transfer complete" message box will appear. - To end the operation, click on the "OK" button. 4-2
44 Chapter 4: Reading and Writing Parameters and Images 4-3 Verify Verify that the parameter settings and images are the same in the personal computer and the IV-S30/ C35M. 1. Select the "Verify" item using the following menu sequence. "IVS30 communication" "IVS30 data transfer" "Verify" Click here IV-S30/C35M 4 - The dialog box for the "Verify" session will appear. 2. Click on the "Start" button to start the data transfer. - If you want to specify or modify the transfer or communication conditions, click on the "Option" button. - [Chapter 2: Optional settings] 3. After the transfer is complete, the "Data transfer complete" message box will appear. - To end the operation, click on the "OK" button. 4-3
45 Chapter 4: Reading and Writing Parameters and Images 4-4 Initialization Initialize all parameters in the IV-S30/C35M. 1. Select the "Initialize" item using the following menu sequence. "IVS30 communication" "IVS30 data transfer" "Initialize" IV-S30/C35M 4 - The dialog box for the "Initialize" will appear. Click here 2. Click on the "Start" button to start the data transfer. - If you want to specify or modify the transfer or communication conditions, click on the "Option" button. - [Chapter 2: Optional settings] 3. After the transfer is complete, the "Data transfer complete" message box will appear. - To end the operation, click on the "OK" button. 4-4
46 Chapter 4: Reading and Writing Parameters and Images 4-5 Self diagnosis Start the self-diagnosis function in the IV-S30/C35M. 1. Select the "Self test" item using the following menu sequence. "IVS30 communication" "IVS30 data transfer" "Self test" - The dialog box for the "Self test" will appear. Click here IV-S30/C35M 4 2. Click on the "Start" button to start the self-diagnosis. - If you want to specify or modify the transfer or communication conditions, click on the "Option" button. - [Chapter 2: Optional settings] 3. After the transfer is complete, the "Data transfer complete" message box will appear. - To end the operation, click on the "OK" button. 4-5
47 Chapter 3: File Operations Chapter 5: File operations Save the IV-S30/C35M's parameter settings and images in a file or load the same type of stored data back into the IV-S30SP. The "File" menu shown below is used by all the parts of this program. Ë New Start a new file from the IV-S30SP parameter. All of the parameters will be set to their default values. - Select the "New" item from the "File" menu. IV-S30/C35M 5 Ë Open You can open the types of files listed below. File extensions Details *.bmp Bit map file of the display and reference images *.msr Object type setting conditions *.prm Global conditions - Select the "Open" item from the "File" menu. - The "Open" dialog box will appear. Ë Save the currently displayed image Save the image that is currently open on the IV-S30SP. - Select the "Save display image" item from the "File" menu. - The "Save display image" dialog box will appear. Ë Open project Open a project file (*.apm). - Select the "Open project" item from the "File" menu. Ë Save project Save all of the files currently open, which have any of the extensions described in the "Open" file section. The files, including all of the data, are seved in a project file (*.apm). - Select the "Save project" item from the "File" menu. 5-1
48 Chapter 3: File Operaions Ë Save As project Save all of the files currently open, which have any of the extensions described in the "Open" file section. The files, including all of the data, are saved in a new project file (*.apm). The data is stored under the new name. - Select the "Save As project" item from the "File" menu. Ë Close project Close the project files (*.apm). - Select the "Close project" item from the "File" menu. Ë Property Select the controller type you are using and enter a project name. IV-S30/C35M 5 1. Click on the [Properties] item on the [File] menu. Click here 2. The [Properties] dialog box will appear. *1 *2 *1: When the IV-S31M/S32M software version is V1.**. *2: When the IV-S31M/S32M software version is V2.**. - When the controller type is changed, the software will automatically change the project s parameters. Note: A project file is a file used to manage all of the various types of parameters in the IV-S30/C35M. 5-2
49 Chapter 6: Document Creation Chapter 6: Document Creation You can automatically create a spreadsheet (table of the current parameters) using Excel or other standard applications, so that you can easily manage and store parameter sets as documents. 6-1 Document creation (Project file) This section describes the procedures for creating a document that contains the parameters in a personal computer file. (1) Setting/operating the IV-S30/C35M Bring up the MAIN OPS MENU screen on the IV-S30/C35M. (2) Communication setting Set the parameters for communicating with the IV-S30/C35M. - See "Chapter 2: Optional settings." (3) Loading the parameters 1. Click the "Create document" item on the "Tools" menu. IV-S30/C35M 6 Click here - The "Create document" dialog box will appear. Continued on the following page 6-1
50 Chapter 6: Document Creation From the previous page (4) Create a document from a project file. Click on the "Open project file" item in the "File" menu. Click here IV-S30/C35M 6 - The dialog box for "Open project file" will appear. (5) Select a file Select the project file that you want to create a document from in the "Create document" dialog box (project file extension: *.apm). (6) Document creation details Check the boxes next to all of the conditions you want to use in creating the document. Then, click on the "Create document" menu. - The dialog box for saving the file will appear. Enter the new document file name (document creation file extension: *.csv). 6-2
51 Chapter 6: Document Creation 6-2 Document creation (IV-S30/C35M parameter loading) This section describes the procedures for creating a document from the parameters already in the IV- S30/C35M. (1) Select a file in which to save the parameter settings Click on "Read parameters" on the "IV-S30 data Transfer" menu. Click here - The "Read parameters" dialog box will appear. (2) Start data transmission Click on the "Start" button to start the data transmission. IV-S30/C35M 6 Click here * Click here * If you want to specify or change the communication settings, select the "Communication setting" item in the "IVS30 data Transfer" menu, or click on the "Set Comm" button in the "Read parameters" dialog box. 6-3
52 Chapter 6: Document Creation [Example of document creation] Shown below is an example file document (with ".csv" extension) that contains conditions for each object type and can be opened using Excel. IV-S30/C35M 6 <<< Object type number 00 >>> TITLE ---- Main ---- MEAS.0, CAMERA 1 MEAS.0, CAMERA 2 MEAS.1 MEAS.2 MEAS.3 HALT MEAS ON NG POS. ADJ.CAMERA 1 POS. ADJ.CAMERA 2 SAMPLE ---- Positional deviation measurement (Camera 1) ---- [MEAS. PROG. COND] * Registration number 0 Mode 2 point search <First point> MEAS WINDOW RECTANGLE REF IMAGE upper left X COORD 68 REF IMAGE upper left Y COORD 232 REF IMAGE lower right X COORD 139 REF IMAGE lower right Y COORD 295 SEARCH AREA upper left COORD 60 SEARCH AREA upper left COORD 224 SEARCH AREA lower right COORD 147 SEARCH AREA lower right COORD 303 DTECT COORD CNTR DTECT COORD (X) 104 DTECT COORD (Y) 264 CONTR. PIXEL 3 <Second point> MEAS WINDOW RECTANGLE REF IMAGE upper left X COORD 356 REF IMAGE upper left Y COORD 232 REF IMAGE lower right X COORD 427 REF IMAGE lower right Y COORD 295 SEARCH AREA upper left COORD 348 SEARCH AREA upper left COORD 224 SEARCH AREA lower right COORD 435 SEARCH AREA lower right COORD 303 DTECT COORD CNTR DTECT COORD (X) 392 DTECT COORD (Y) 264 CONTR. PIXEL 3 DETECT ACCURACY STANDARD POSITIONAL DEVIATION MEASUREMENT NO NO NO NO NO NO CALIBRATION NO CALIBRATION 6-4
53 Chapter 7: Data Collection Chapter 7: Data Collection (Measurement result/ng image) You can transmit the measurement result/ng image result data from the IV-S30/C35M to a personal computer via communication cable (general purpose serial I/F), and automatically create a result sheet. The data collection function is used to manage or save measurement data, and collect data settings such as the evaluation conditions. - For details about setting the specific controller model, see page 5-2. This chapter explains the procedures for data collection. (1) Setting/operation of the controller 1. Select "BLOCK-ASSIGN" on the "SERIAL OUTPUT" line of the [OBJ-TYPE I/O] menu. When using the IV-S31MX/S32MX/S33MX, IV-S30J, or IV-C35M OBJ-TYPE I/O SCREEN SAVE 2 1TRIG CCD START NO 2SHUTTER SPEED 3SERIAL OUTPUT 4SET SERIAL BLOCK 5CALIBRATION (TO NEXT SUB-MENU) IV-S30/C35M 7 When using the IV-S31M/S32M/S33M On the "MAIN OPS MENU," move the cursor to MEA-CND and press the SET key. - On the [TYPE MEAS COND] menu, move the cursor to [I/O] and press the SET key. [TYPE MEAS COND] 1OBJECT TYPE NO.00(0~63) NO YES 2 OPS-MENU SAVE LOCK TITLE FINAL-CALC FINAL-OUTPUT I/O SYSTEM [OBJECT TYPE I/O] 1TRIG CCD START NO YES(BIN AVG-GRAYS GRAY-SRC) 2CCD TRIG COND (TO NEXT SUB-MENU) 2CCD TRIG COND (TO NEXT SUB-MENU) 3SHUTTER SPEED 1/00060(1/30 1/10000) 4SERIAL OUTPUT ANY BLOCK-ASSIGN 5SET SERIAL BLOCK BLOCK00 MEAS0 CAM1 2. Assign block numbers to be used to collect data on the "SET SERIAL BLOCK" line. Continued on the following page 7-1
54 Chapter 7: Data Collection From the previous page 3. Set the "SERIAL OUTPUT" or "OUT I/F (PARAL.)" item on the [I/O CONDITIONS] menu. The settings will depend on the type of controller you are using. When using the IV-S31MX/S32MX/S33MX, IV-S30J, or IV-C35M Select "No." I/O CONDITION SCREEN COND SAVE IV-S30/C35M 7 1MEAS INP I/F 2OUT I/F(PARAL.) 3MANL TYPE CHNG 4PARALLEL INP X6 5PARALLEL INP X7 6STROBE 7 PARALLEL + SERIAL + USB NO NO EXT-INP EXT-INP NO When using the IV-S31M/S32M/S33M The settings will depend on the type of controller (software version) you are using. On the "MAIN OPS MENU," move the cursor to [SYS-CND] and press the SET key. - On the [SYSTEM COND] menu, move the cursor to "1I/O CONDITIONS" and press the SET key. [SYSTEM COND] 1I/O CONDITIONS 2COMM. SET [I/O CONDITIONS] 1MEAS INP I/F 2SERIAL OUTPUT 3MANL TYPE CHNG 4PARALLEL INP X6 5PARALLEL INP X7 6STROBE OUT 7 READY ON (TO NEXT SUB-MENU) (TO NEXT SUB-MENU) *1 PARALLEL+SERIAL+USB CCD-TRIG *2 NO PC-LINK SERIAL NO YES 64OBJ-CHG REG REF(MEAS0 COMPARE-IMGS) MODIFY-AREA-SIZE(00%) EXT-INP EXT-INP CHNG-IMG-OUT-CAM CAM-MEAS 2 IMAGES NO Y0 CAPTURE COMPLETE MEAS-COMPLETE *1: When the IV-S33M, IV-S31M/S32M (software version V2.01 or later) is used. - Select "NO." *2: When the IV-S31M/S32M (software version V1.15 or before) is used. - Select "SERIAL." 4. Return the IV-S30/C35M screen to the "MAIN OPS MENU." Continued on the following page 7-2
55 Chapter 7: Data Collection From the previous page (2) Starting the data collection screen Click on the "Data collection" item in the "Tools" menu. Click here - The "Data collection" dialog box will appear. (3) Communication settings Specify the communication settings by selecting the "Communication setting" item in the "Setting" menu on the IV-S30SP program and communication setting of the IV-S30/C35M. IV-S30/C35M 7 Click here (4) Sampling setting 1. Click on the [Sampling setting] item on the [Setting] menu. Click here - The [Sampling setting] dialog box will appear. 2. Set the sampling data, number of samples, and data processing required in the screen below, according to your use and application. The number of samples and data processing settings affect the "measurement result data" obtained from the sampling data. "NG image data" can be selected when "USB" is selected for the communication method (see above). Continued on the following page 7-3
56 Chapter 7: Data Collection From the previous page [Sampling data] - Measurement result data: Collect the results from the data measured. - NG image data: Collect NG images. (In order to collect NG images, select "YES" for NG image registration on the "OB- JECT TYPE SYS." menu on the controller (except IV-S31M/S31MX.)) [Number of sampling] Enter the number of samplings and method here : Collect up to 1000 sets of data : Collect up to 5000 sets of data - Unlimited: Save data on a hard disk (the sampling speed will be slower). IV-S30/C35M 7 [Data processing] Set the data processing method for the data samples. - Count the number of samples in each set of measurement data: Total the number of data samples in each set of measurement data, and output the total and number of samples. - Sort in measurement order: Output the measurement results in same order that the samples were taken. (5) Setting the data collection conditions 1. Click on the "Setup" button. Click here - Load the IV-S30/C35M parameters and display the data collection conditions that can be specified. 2. Select the items for data collection. Continued on the following page 7-4
57 Chapter 7: Data Collection From the previous page (6) Execute a data collection Click on the "Start" button. Click here - Now the IV-S30SP is ready to load data. (7) Create a summary table of the measurement data, collect NG image data IV-S30/C35M Click on the "Cancel" button. - The data collection will stop. 2. Click on the "Create a data list" button. - When the [Open] dialog box appears, select the directory position and assign a file name in which to save the data. - The data summary file will be created automatically. - The file extension used for the measurement data is "csv" and NG image data is saved as "bmp" files. Note - If processing speed of a personal computer is slower than the data transmission speed of the IV- S30/C35M, some parts of the data may be lost. - Displaying the real time chart will reduce the IV-S30SP program's processing speed. 7-5
58 Chapter 7: Data Collection [Data collection example] Shown below is an example in which the graph creation feature in Excel is used to make a graph of the measured data file (with ".csv" extension) created with the data collection function. Example: Measuring an area by binary conversion, and setting the upper and lower limits for the evaluation conditions of the surface area. IV-S30/C35M 7 Data file (with.csv extension) Create a table using Excel. Create a graph using Excel. Area Frequency Lower limit Upper limit Series 2 15 NG OK
59 Chapter 8: User Menu Editor Chapter 8: User Menu Editor This function lets you create and modify the MAIN OPS MENU screen and all of the other user menus on the IV- S31M/S32M/S33M. You can also change the text and titles displayed on those screens. - For details about setting the specific controller model, see page How to start the editor 1. Click on the "User menu editor" item on the "Tools" menu. Click here - The user menu editing screen will appear. IV-S30/C35M
60 Chapter 8: User Menu Editor 8-2 Read Read in the menu you want to edit, or select the MAIN OPS MENU screen, from the IV-S33M etc. 1. Click on the "Data Transfer" item in the "File" menu. Click here IV-S30/C35M The "Data transfer" screen will appear. 2. Select "Read" in the "Data transfer condition" area and check the boxes next to the items you want to read in the "Items to transfer" area. Click on the "Start" button to read the data from the IV-S33M etc. 8-3 Write Write new or modified menus, or the MAIN OPS MENU screen, back into the IV-S33M etc. 1. Click on the "Data Transfer" item from the "File" menu (see "8-2 Read"). - The "Data transfer" screen will appear. 2. Select "Write" in the "Data transfer condition" area. In the "Items to transfer" area, check all of the boxes next to the items you want to send back to the IV-S30. Click on the "Start" button to write the data back into the IV-S33M etc. 8-2
61 Chapter 8: User Menu Editor 8-4 Initialize the user menus 1. Click on the "Data Transfer" item in the "File" menu (see "8-2 Read"). - The "Data transfer" screen will appear. 2. Select "Initialize user menu" in the "Data transfer condition" area. Click on the "Start" button to initialize the user menus in the IV-S33M etc. IV-S30/C35M
62 Chapter 8: User Menu Editor 8-5 Editing Titles The word "title" refers to the "MEAS SHAPE (MDL0)" text shown inside the rectangle, in the example below. MEAS SHAPE (MDL0) RECTANGLE X-LINE Y-LINE 1. Change the title. Click on the "Title" tab to display the title list. Double-click on the title you want to change. IV-S30/C35M The "Modify character strings" dialog box will appear. 2. Change or delete the characters directly in the dialog box, and then click on the "OK" button. The title will be changed. Ë To search for a title you want to change 1. Select the "Find" item from the "Edit" menu. (You can also select the "Find" item from the pop up menu, by clicking the right mouse button when the cursor is over any title.) Click here 8-4
63 Chapter 8: User Menu Editor - The "Find Title list" dialog box will appear. 2. Enter the phrase you want to find. Then click on the "Execute" button to start the search. 8-6 Editing character strings "Character strings" refers to the words which come after the title, such as "RECTANGLE," "VER-LINE," and "HORI-LINE" shown inside the rectangles in the example below. MEAS SHAPE (MDL0) RECTANGLE X-LINE Y-LINE 1. To change a character string. Click on the "Character string" tab to display the character string list. Double-click on the text you want to change. IV-S30/C35M For details about changing, deleting, and searching for text, see section, "8-5 Editing Titles." 8-5
64 Chapter 8: User Menu Editor 8-7 Menu editing "Character strings" refers to any part of the complete line of text in the example below. MEAS SHAPE (MDL0) RECTANGLE X-LINE Y-LINE Ë To change the title or any of the text which comes after it in the menu 1. Select the menu item in the menu list. The title and character string will be displayed in the menu details list. IV-S30/C35M Double-click on the title or character string in the menu details list that you want to change. The "Modify character strings" dialog box will appear. For details about changing, deleting, and searching for text, see section, "8-5 Editing Titles." 8-6
65 Chapter 8: User Menu Editor 8-8 Create a user menu 1. Click on the "Create user menu" item in the "File" menu. Click here - The table for creating a user menu will appear. IV-S30/C35M Select the menu that you want to assign as a user menu from the menu list. To add the item, drag and drop it onto the menu table. 8-7
66 Chapter 8: User Menu Editor 8-9 Create a new MAIN OPS MENU screen 1. Click on the "Create MAIN OPS MENU menu" item from the "File" menu. Click here - The table for creating a MAIN OPS MENU screen will appear. IV-S30/C35M To add a new user menu, select the "Create user menu" item from the "File" menu. The table for creating a new menu will appear. - You can create up to two screens for the IV-S31M, and eight screens for the IV-S32M/S33M. 8-8
67 Chapter 8: User Menu Editor 3. Select the area that you want to assign to the MAIN OPS MENU screen from the area list. To add the item, drag it to the MAIN OPS MENU table. You can change the display position once it is in the table File operation Ë Create a new file All the data on the menu editor will be initialized. - Select the "New" item from the "File" menu. IV-S30/C35M 10 8 Ë Open a file Open a saved file. - Select the "Open" item in the "File" menu. File extensions *. str *. ume *. urm *. fnt Details Title and character string data User menu data MAIN OPS MENU data User font data 8-9
68 Chapter 9: Command Test Chapter 9: Command Test The command test function is used to communicate to the IV-S30/C35M through the serial or USB interface and confirm that communication has been established when the personal computer is started. This chapter describes the command test procedures. (1) Setting/operating of IV-S30/C35M 1. Set the "SERIAL OUTPUT" item in the "I/O CONDITIONS" menu of the IV-S30/C35M to "SERIAL." When using the IV-S31MX/S32MX/S33MX, IV-S30J, IV-C35M I/O CONDITION SCREEN COND SAVE 1MEAS INP I/F 2OUT I/F(PARAL.) 3MANL TYPE CHNG 4PARALLEL INP X6 5PARALLEL INP X7 6STROBE 7 1I/O CONDITIONS 2COMM. SET PARALLEL + SERIAL + USB NO EXT-INP EXT-INP NO When using the IV-S31M/S32M/S33M (TO NEXT SUB-MENU) (TO NEXT SUB-MENU) Bring up the MAIN OPS MENU screen on the IV-S30/C35M. IV-S30/C35M 119 (2) Communication settings Set the protocols for communication with the IV-S30/C35M. - See "Chapter 2: Optional Settings." (3) Starting the command test screen Click on the "Command Test" item on the "Tools" menu. Click here - The "Command test" dialog box will appear. Continued on the following page 9-1
69 Chapter 9: Command Test From the previous page (4) Setting the conditions for the command test In the "Command test" dialog box, set the conditions for the command test (set the time out, checksum, and number of repeats). IV-S30/C35M 19 Setting details Setting the time out (O: 10 sec.) Checksum Automatic O Manual Description Specify the communication time-out time, in units of seconds. Calculates the checksum automatically, and attaches it to the transfer command. Enter a checksum together with the command. (The IV-S30SP will not attach the checksum when transmitting.) Number of repeats (O: 1 time) F ixed (@@) A checksum is not executed, will be transmitted. - The "O" indicates the default setting. Send the command that was entered in the send data box the same number of times as specified in the "number of repeats" box. (5) Transmitting serial command Enter the data to send in the "Command test" dialog box, and press the "Send" button. - The data will be transmitted to the IV-S30/C35M. The response data will be displayed in the receive data area. Enter the data to send Checksum values Display the data received Click here Continued on the following page 9-2
70 Chapter 9: Command Test From the previous page (6) Saving files - Saving the data received to a file 1. Click on the "Open" item in the "File" menu. - The "Open" dialog box will appear. - When you want to create a new file (with the ".tst" extension) to save the data received, specify the folder name, enter the file name, and click on the "Open" button. If you want to save it to an existing file, select the file and click on the "Open" button. 2. Click on the "Save" item in the "File" menu. IV-S30/C35M
71 Chapter 10: Upgrade Version Chapter 10: Upgrade Version To upgrade the IV-S30/C35M system version (improved functions) you simply download the new version from a personal computer. - The IV-S30/C35M software consists of the "system program," used to set up and execute image processing operations, and a "boot program" to load the other programs. In some cases, both programs need to be upgraded. (Refer to our sales department for the latest version of the system software.) Described below are the procedures for upgrading the program version. (1) Preparation Create the folders below for installing the software. SXXYYY.mot system program BXXYYY.mot boot program "XX" will vary depending on the models, and "YYY" will vary depending on the versions. (2) Communication settings Set the protocols for communication with the IV-S30/C35M. - See "Chapter 2: Optional settings." (3) Setting/operating of IV-S30/C35M 1. Turn on the IV-S30/C35M. - Turn on the controller IV-S30/C35M, while pressing and holding down both the left key (\) and the set key (SET) on the remote key pad at the same time. IV-S30/C35M 10 Left key (\) Set key (SET) - The IV-S30/C35M upgrade version menu (IV**** VERSION UPGRADE MENU) will appear on the monitor. [IV-S3*** VERSION UPGRADE MENU] 1IVS3*** SYSTEM RECEIVE (USB) 2IVS3*** SYSTEM RECEIVE (RS232C) 3BOOT RECEIVE (USB) 4BOOT RECEIVE (RS232C) 5RS232C BAUDRATE 6ALL INITIALIZE 7POWER ON RESET (When an IV-S3*** is used) RUN RUN RUN RUN 115.K bps 19.2K bps RUN RUN 2. Select the upgrade version menu. - Move the up and down keys to select the "1 IV-S3*** SYSTEM RECEIVE (USB)" item and press the set key (SET). (The "3 BOOT RECEIVE (USB)" item may also be needed to perform the upgrade, depending on the upgrade conditions.) Continued on the following page 10-1
72 Chapter 10: Upgrade Version From the previous page (4) File selection Click on the "Version upgrade" item on the "IVS30 communication" menu. Click here - The "Open" dialog box will appear. - Select the (SXXYYY.mot) file and click on the "Open" button. IV-S30/C35M 10 (5) Transmission The "Version upgrade" screen will appear. Click here - Click on the "Option" button. Specify the communication and upgrade conditions. (See pages 2-1, 2-2, and 2-4.) Click on the "Start" button to start the data transmission. (To stop the transmission, click on the "Cancel" button.) - When the [ ON RECEIVE ] message appears on the IV-S30/C35M monitor and the [ ] flashes, the transmission has been successful. - It takes approximately 20 seconds to transmit the complete file through the USB interface. (Note: When an RS-232C interface is used, it will take approximately 10 minutes with a Pentium 266 MHz personal computer.) - When the [ ON RECEIVE ] display disappears, the new system program has been successfully written to the flash memory. (6) Starting the new version of the system Move the up and down keys to select "7 POWER ON RESET" on the IV-S30/C35M upgrade version menu (displayed on the monitor) and press the [SET] key. [IV-S3*** VERSION UP MENU] 1IVS3*** SYSTEM RECEIVE (USB) 2IVS3*** SYSTEM RECEIVE (RS232C) 3BOOT RECEIVE (USB) 4BOOT RECEIVE (RS232C) 5RS232C BAUDRATE 6ALL INITIALIZE 7POWER ON RESET RUN RUN RUN RUN 115.K bps 19.2K bps RUN RUN (When an IV-S3*** is used) - The power to the IV-S30/C35M will be reset and the new version of the system program will start. 10-2
73 Chapter 11: Additional Descriptions Chapter 11: Additional Descriptions This chapter describes other functions such as Printing, Changing the Message Display Color, Changing the Image Brightness, Accessing the SMS Web page and Memory card (IV-C35M). [1] Print Images displayed on the IV-S30SP monitor can be printed. (Printing procedure) 1. Click on the "Print" item in the "File" menu. Click here [2] Changing the message display color You can select oen of 8 colors for the display image color. If the image and the message are same colors, use different message color to allow you to see the message. - The colors you can chose from are black, blue, green, cyan, red, magenta, yellow, and white. (Operation procedures) 1. Move the cursor to "Message color" on the "View" menu. IV-S30/C35M Select a color. Select the desired color. (Default: black) - The message color will be changed. 11-1
74 Chapter 11: Additional Descriptions [3] Zoom You can change the display magnification of the image by changing the zoom setting. (Zoom setting) 1. Select the "Zoom magnification rate" item in the "View" menu. 2. Select a rate. Click on the level of magnification you want. (Default: 100%) - The zoom setting will be changed. IV-S30/C35M 11 [4] Changing the image brightness You can set the displayed image brightness to "Standard" or "1/2." (Operation procedures) 1. Move the cursor to the "Display image Bright level" item on the "View" menu. 2. Select a brightness. - Click on "Standard" or "1/2." (Default: Standard) - The displayed image will be changed to the selected brightness. 11-2
75 Chapter 11: Additional Descriptions [5] SMS Web page If your personal computer is ready to connect to the Internet, the default Web browser will be started and automatically connect you to the Sharp Manufacturing Systems Corporation Web site. (The URL address is listed on the back cover of this manual.) (Connecting to the Sharp web site) 1. Select the "SMS Web page" item in the "Help" menu. IV-S30/C35M
76 Chapter 11: Additional Descriptions [6] Memory card (IV-C35M) When the IV-C35M is used, you can read, save, or delete data from a flash memory card (max. 192 MB) using the IV-S30SP. (Operation procedures) 1.Select the "Memory card" on the "Tools" popup menu. IV-S30/C35M Select any operation, such as "Read", on the "Memory card" popup menu. - A dialog box will open for the selected operation. Read Save Operation Save as name Delete Details Read the IV-C35M parameters and NG images that were stored on the flash memory card. Copy and paste the IV-C35M parameters and NG images that were stored in a PC onto the flash memory card. Create a file with a new name for the IV-C35M parameters and NG images that were stored on the flash memory card, and save it on the flash memory card. Delete the IV-C35M parameters and NG images that were stored on the flash memory card. 3. Specify file type (parameter or NG image) and select the drive, directory, and file on the flash memory card. Then click on the [OK] button. - The specified operation will be executed. (When reading data) 11-4
77 Version for the IV-S20
78 Chapter 1: Menu Organization Chapter 1: Menu Organization After starting this software (for the IV-S20), the screen shown below will appear. The menu organization on the menu bar is also shown below. The following menus (1) to (7) correspond to the items from the next page. (1) (2) (3) (4) (5) (6) (7) - This screen will be displayed when this software (for the IV-S20) is started. IV-S
79 Chapter 1: Menu Organization (1) File (Description) New Ctrl + N Open image Ctrl+O Save Image only Messages only Image + Message Create a new file. Open an existing image file. (*.bmp) Save the display images only. Save messages only. Save both the images and messages. Read image Display image (Camera 1) Display image (Camera 2) Message Write image Display image (Camera 1) Display image (Camera 2) Set Communication Command Test Print Ctrl+P Select printer type Read the display image (camera 1) from the IV-S20. Read the display image (camera 2) from the IV-S20. Read messages from the IV-S20. Write the display image to the IV-S20. Write the display image to the IV-S20. Set the communication conditions of the IV-S20SP. Send any serial command to the IV-S20. Print Set up a printer. Exit Ctrl+Q Quit the IV-S20SP. (2) Edit IV-S20 1 Delete display image DISP image bright level Normal Half Copy display image Message color Image only Messages only Image + Message Black, Blue, Green, Cyan, Red, Magenta, Yellow, and White (Description) Delete the images displayed on the IV-S20SP. Set the display image brightness to normal. Decrease the display images brightness to half level. Copy the images only to the clipboard. Copy messages only to the clipboard. Copy both the image and messages to the clipboard. Change the message display color to the specified color. 1-2
80 Chapter 1: Menu Organization (3) IV data settings Select a file Load File - IV File - Set screen Set screen - IV Save IV - File Set screen - File IV - Set screen Verify File =- IV File =- Set screen IV =- Set screen Initialize IV-S20 Set screen Self diagnosis IVS20 Creates a document Data collection (Description) Select an IV-S20 setting data file to treat. Load the setting parameters from the file to the IV-S20. Load the setting parameters from the file to the set screen. Load the setting parameters from the set screen to the IV-S20. Save the setting parameters from the IV-S20 to the file. Save the setting parameters from the set screen to the file. Save the setting parameters from the IV-S20 to the set screen. Verify the file with the IV-S20 setting parameters. Verify the file with the set screen setting parameters. Verify the IV-S20 data and the set screen setting parameters. Initialize the IV-S20. Initialize the set screen. Self diagnose the IV-S20. Automatically create the setting data document. Save the measurement result data from the IV-S20. IV-S
81 Chapter 1: Menu Organization (4) Object type COND (Description) Object type NO. (0-15) Title registration MEAS.0 Camera 1 MEAS-POSITION-DEVIATE POS.ADJ. Camera 1 MEAS.0 Camera 2 MEAS-POSITION-DEVIATE Set and change object type number. Set a title to each object. Set and change each condition of positional deviation measurement (Camera 1). Set and change position adjust condition. Set and change each condition of positional deviation measurement (Camera 2). POS.ADJ. Camera 2 IV-S20 1 Measurement 1 CHECK-DEG-OF-MATCH DIST/ANGLE (GRAY/EDGE) DIST/ANGLE (C-GRAV) INSPECT-LEADS MEASR-BIN-AREA COUNT-BIN-OBJ LABEL-BIN-OBJ MEASURE POINTS Measurement 2 (Same as Measurement 1) Measurement 3 (Same as Measurement 1) FINAL NUMERIC CALC FINAL OUTPUT COND SYSTEM-IN/OUT HALT MEAS ON NG NO YES Set and change various conditions of degree of match inspection. Set and change various conditions of distance and angle measurement (gray and edge). Set and change various conditions of distance and angle measurement (Gravity center). Set and change various conditions of lead inspection. Set and change various conditions of area measurement by binary conversion. Set and change various conditions of counting quantities by binary conversion. Set and change various conditions of label measurement by binary conversion. Set and change various conditions of point measurement. Set and change various conditions of final calculation result. Set and change various conditions of final output condition. Set and change various conditions of system-in/out for each object style. Continues measurements even if a NG evaluation occurs. Halt all measurement if a NG evaluation occurs. 1-4
82 Chapter 1: Menu Organization (5) Version up Select a file Transfer data Without INIT Transfer data and INIT MEAS COND Transfer data and INIT All data (Description) Select a file to meet version of the IV-S20. After data transmission, upgrades the version without initialization. After data transmission, upgrades the version with initializing measuring conditions. After data transmission, upgrades the version with initializing all. (6) Window Monitor display image Option All object type list display Object type display Tool bar Status bar Cascade display Tile Vertically Tile Horizontally (Description) Change between display or not display the display image. Display conditions of all object types on the setting screen. Display conditions of one object type on the setting screen. Change between display or not display the tool bar. Change between display or not display the status bar. Overlap the open windows. Display the open windows in a vertical layout. Display the open windows in a horizontal layout. (7) Help Search topic About program information (Description) Display the help menu search topic screen. Display the version information for the IV-S20SP program. IV-S
83 Chapter 2: Set Communication Chapter 2: Set Communication When you communicate between the PC and the IV-S20, you must specify the "Set communication." Ë Communication menu items Display items for communication between the PC and the IV-S20. Read image Write image File Display image (Camera 1) Display image (Camera 2) Message Display image (Camera 1) Display image (Camera 2) Load Save Verify Ë Operation of the communication settings 1. Click "Set Communication" on the "File" menu. IV data settings File - IV Set screen - IV IV - File IV - Set screen File =- IV IV =- Set screen Initialize IV-S20 Self diagnosis IVS20 Data collection Version up Transfer data Without INIT Transfer data and INIT MEAS COND Transfer data and INIT All data Click - The "Set communication" dialog box will appear. 2. Select the port number, and then click the "SET" button. IV-S20 2 Select the communication port Click Setting items Communication speed Number of bits Parity Stop bits Port Default setting kbps 7 Even Set the personal computer s communication port. Setting items other than the "Port" can be operated with the default setting (set at delivery). 2-1
84 Chapter 3: Setting Object Type Conditions Chapter 3: Setting Object Type Conditions Set object type conditions (Measurement conditions, Evaluation conditions, Numerical conditions, and output conditions) by clicking each item from the "Object type COND" menu. - You can set and change the conditions offline. (You can set and change without stopping the line while the production line while it is operating.) - For details about the setting details, see the "IV-S20 user s manual." Ë "Object type COND" menu - "MEAS. 0 Camera 2" is the same operation. - Measurement 2, Measurement 3, are the same operation. Click the item. Each setting screen will appear. Ë Operation details: When setting up the positional deviation measurement Click the "MEAS. 0 Camera 1" or "MEAS.0 Camera 2" from the "Object type COND" menu, then select the "MEAS-POSITION-DEVIATE." Click - The positional deviation measurement setting screen will appear. IV-S
85 Chapter 3: Setting Object Type Conditions 3-1 Setting the measurement conditions Click each measuring program from the "Object type COND" menu. The "MEASUREMENT CONDI- TIONS" screen will appear. Ë Operation details: When setting up the positional deviation measurement (1-point search + 1-point edge) 1. Click the "YES" button on the "REG." on the position deviation measurement setting screen (previous screen.) Click - The setting screen for the "1P-SCH" (1-point search) will appear. 2. Click the """ of the "MODE", then select the "1P-SCH + 1P-EDGE." Click - The "MEASUREMENT CONDITIONS" screen for the "1P-SCH + 1P-EDGE" will appear. IV-S20 3 Gray search conditions setting items. Edge detection conditions setting items. For details about the settings, see the "IV-S20 user s manual." 3-2
86 Chapter 3: Setting Object Type Conditions 3-2 Setting the evaluation conditions Click the "EVALUATION CONDITION" from each measuring program setting screen. The "EVALUA- TION CONDITION" screen will appear. Ë Operation details: When setting up the positional deviation measurement (1 point search + 1 point edge) Click the "EVALUATION CONDITION" in the positional deviation measurement setting screen (previous screen.) Click - The "EVALUATION CONDITION" screen for the "1P-SCH + 1P-EDGE" will appear. The registration number setting items. MODEL 0 setting items. Angular deviation setting items. MODEL 1 setting items. IV-S20 3 For details about the settings, see the "IV-S20 user s manual." 3-3
87 Chapter 3: Setting Object Type Conditions 3-3 Setting the numerical calculation conditions Click the "NUMERIC CALC. COND" from each measuring program setting screen. The "NUMERIC CALC. COND" screen will appear. Ë Operation details: When setting up the positional deviation measurement Click the "NUMERIC CALC. COND" on the position deviation measurement setting screen (page 3-2). Click - The "NUMERIC CALC. COND" screen for positional deviation measurement will appear. Display each setting detail. The setting table for numerical calculation (N00 to N15.) IV-S Click each setting section (object type, upper&lower limit, output, and formula) for numerical calculation. The each setting detail will appear. (See the next page.) 3-4
88 Chapter 3: Setting Object Type Conditions Click on each of the individual setting sections 1 to 5 below, on the numerical calculation setting table. The details of each setting will appear. 1 Object type setting details 2 Setting details for upper & lower limit 3 Setting details for output 4 Setting details for formula 1-1 (When the type is X and Y coordinates, x and y positional deviation coordinates, and degree of match M, or angular deviation B) When angular deviation B is selected, the model item is not displayed. 4 Setting details for formula 1-1 (When the type is a numerical calculation NC) 4 Setting details for formula 1-1 (When the type is a Constant C) 5 Setting details for formula IV-S20 3 For details about these setting details, see the "IV-S20 user s manual: Chapter 9: Numerical Calculations." [Example of settings] The setting process of the calculation result N01 is described on the next page. 3-5
89 Chapter 3: Setting Object Type Conditions Described below is the process used to set the calculation result N01 for the setting example shown on the previous page. (1) Setting the object type 1. Click the "TYPE" cell N01. Click - The setting details for object type will appear. 2. Click the "COORD [X]." Click - The [X] will be indicated on the "TYPE" cell N01. (2) Setting the formula 1. Click the "FRMLA" cell N01. Click - The setting details for formula 1 will appear. 2. Click the "REG." item. A number " " will appear by clicking the "N00" cell on the left side. IV-S20 3 Click - A "0X0" will be indicated. 3. Click the right cell of the "0X0." - The setting detail for formula 2 will appear. 4. Click the [*] item. Click Click - The "*" will be indicated on the right cell of the "0X0." 5. Click the right cell of "*", then click the "N" item in the setting detail for formula 1. - The "N0" will be indicated on the right cell of the "*." Continued on the following page 3-6 Displayed
90 From the previous page Chapter 3: Setting Object Type Conditions From the previous page (3) Setting the upper & lower limits 1. Click the "LOW-LMT" (lower limit) or "UP-LMT" (upper limit) cell on the "N01" line. Click here - The setting detail for the upper limit or lower limit will appear. 2. Double-click the inside of the upper limit item. Double-click here - The display will be highlighted. 3. Type in the number "410", then press the "Enter" key. - The number " " will be indicated. Indicated (Reference) You can also set the upper & lower limits by clicking on the number of digits and '/" buttons. 1 Click the " item to select the number of digits. 2 Click the '/" item of the upper & lower limit. (4) Set the output. 1. Click the "OUTPUT" cell on the "N01" line. - The setting detail for the output will appear. 2. Click "Y." IV-S20 3 Click - A "Y0" will be displayed on the "OUT" cell of the "N01" line. Displayed 3-7
91 Chapter 3: Setting Object Type Conditions 3-4 Setting the output condition Click the "OUTPUT CONDITIONS" from each measuring program setting screen. The "OUTPUT CON- DITIONS" screen will appear. Ë Operation details: When setting up the positional deviation measurement Click the "OUTPUT CONDITIONS" on the position deviation measurement setting screen (page 3-2). Click - The "OUTPUT CONDITIONS" screen for positional deviation measurement will appear. Input signal items to set Logical symbol items to set Output signal item to set IV-S20 3 æ Display of page 4 Click this range on the screen above. The page 4 will be displayed. For details about these settings, see the "IV-S20 user s manual: Chapter 10: PC Function." 3-8
92 Chapter 3: Setting Object Type Conditions [Example of settings] Described below is the process used to create the example above. 1. Click the column 0 on the "INPUT 0" line (PAGE 0). Click here 2. Click on the [ ] item in the "LOGICAL SYMBOL" area. Click 3. Click on the [MATCH M] item in the "INPUT SIGNAL" area. ` (For reference of the below) Click - The selected input signal and logical symbol will be shown. (Reference) - Enter the registration number (0 to 7) and the object type number (0 or 1) by clicking the '/" arrows (see above `). 4. To create the input section, click on the desired cell, logical symbol, and input signal repeatedly, the same as in steps 1 to 3 above. 5. Click the column output on the "INPUT 0" line. IV-S20 3 Click here 3-9
93 Chapter 3: Setting Object Type Conditions 6. Click on the [AUXILIARY C] in the "OUTPUT SIGNAL" area. Click `2 `1 - The output signal and the auxiliary relay C000 will be shown in the table. (Reference) - Set the auxiliary relay number (0 to 127) by clicking the '/" item (`1) of auxiliary relay C, or directly enter a number after double-clicking inside the relay number window (`2) to highlight the window. IV-S
94 Chapter 3: Setting Object Type Conditions 3-5 Operation example (positional deviation measurement) This section describes the operation example for positional deviation measurement (2 points search) as a use example of setting Object type conditions. (1) Setting/operating of IV-S20 Let the IV-S20 to show the MAIN OPS MENU screen. (2) Starting up IV-S20SP - See page Setup-4. (3) Communication settings Set the protocols to communicate with the IV-S20. - See "Chapter 2: Set Communication." (4) Assign an object type number Click the "Object type NO. (0-15)" from the "Object type COND" menu. Click - The "OBJECT TYP..." dialog box will appear. Click - Select the object type number (0 to 15) using the "/' buttons. Then click the "SET" button. (5) Starting up the setting screen for the "Positional deviation measurement." Click the "MEAS. 0 Camera 1" "MEAS-POSITION-DEVIATE" items from the "Object type COND" menu. IV-S20 3 Click - The setting screen for the "Positional deviation measurement" will appear. (see the next page.) Continued on the following page 3-11
95 Chapter 3: Setting Object Type Conditions From the previous page - Setting screen of positional deviation measurement (6) Reading display images 1. Click the "Read image" "Display image (Camera 1)" items from the "File" menu. IV-S20 3 Click - The "Read display image (CAM 1)" dialog box will appear. 2. Click the "OK" button. - The display image will be loaded. (See the next page.) Continued on the following page 3-12
96 Chapter 3: Setting Object Type Conditions From the previous page - An example of reading display image (7) Mode settings 1. Specify a register number (0 to 7) using the '/" buttons, then click "YES" in the "REG." window. A register number specification - The measurement conditions for the mode (1 point search) will appear. Click IV-S20 3 Continued on the following page 3-13
97 Chapter 3: Setting Object Type Conditions From the previous page 2. Click the " item on the "MODE," and select "2 P-SCH" (2 points search). Click - The measurement conditions for the mode (2 points search) will appear. The setting frame for the reference image (solid line) The setting frame for the search area (dotted line) IV-S20 3 (8) Registration of the reference image 1. Drag the setting frame of the reference image or the search area using the mouse to define the position. - Example of settings The reference image The search area The reference image The search area frame for the model 0 frame for the model 0 frame for the model 1 frame for the model 1 Continued on the following page 3-14
98 Chapter 3: Setting Object Type Conditions From the previous page 2. Click the "REG." button. Then click the "DISP" button. Registration (model 0) Display (model 0) Registration (model 1) - If an image is registered, its image will be displayed. - Click the "DISP" button again to disappear the image. Display (model 1) æ Loading the measurement conditions to IV-S20 (9) Execute loading 1. Click the "Load" "Set screen - IV" items from the "IV data settings" menu. Click - The "IV data settings" dialog box will appear. 2. Click the "START" item on the "IV data settings" dialog box. - The set measurement conditions will be loaded in the IV-S20. After the loading is complete, the "Load all parameters completed (Set screen IV)" will appear. IV-S
99 Chapter 4: Document Creation Chapter 4: Document Creation You can automatically create a spreadsheet (table of the current parameters) using Excel or other standard applications, so that you can easily manage and store parameter sets as documents. 4-1 Document creation (IV-S20 parameter) This section describes the procedures for creating a document that contains parameters. (1) Setting/operating the IV-S20 Bring up the MAIN OPS MENU screen on the IV-S20. (2) Communication setting Set the parameters for communicating with the IV-S20. - See "Chapter 2: Set Communication." (3) Loading the parameters 1. Click the "Save" "IV -> setting screen" items on the "IV data settings" menu. Click here - The "IV data settings" dialog box will appear. 2. Click the "START" button. Click - The data set in the IV-S20 will be stored on the setting screen. - After the saving data is complete, the "IV data settings" dialog box will appear. 3. Click the "OK" button. IV-S20 4 Click Continued on the following page 4-1
100 Chapter 4: Document Creation From the previous page (4) Starting up the document creation screen Click the "Creates a document" item from the "IV data settings" menu. Click - The "Creates a document" dialog box will appear. (5) Select a file Click "Open" from the "File" menu on the "Creates a document" window. Click - The "Open" dialog box will appear. - When you want to create new file (with ".csv" extension) for making document, specify the folder name, enter the file name, and click the "Open" button. If you want to save it to an existing file, select the file and click the "Open" button. IV-S20 4 (6) Document creation details Select document type and the conditions and click the "Start creation" button. Select object types Select conditions Click - The program will create the document automatically. After the creation is complete, the "Creates a document" dialog box will appear. - Click the "OK" button on the box. (See page 4-4 for the example of the document creation.) 4-2
101 Chapter 4: Document Creation 4-2 Document creation (file data) This section describes the procedures for creating a document from the parameters already in a personal computer file. (1) Select a file in which to save the parameter settings Click on "Select a file" on the "IV data settings" menu. Click - The "Open" dialog box will appear. - Select a file (with ".apm" extension) to create a document, then click the "Open" item. (2) Reading the setting parameters 1. Click the "Load" "File -> Set screen" items from the "IV data settings" menu. Click - The "IV data settings" dialog box will appear. 2. Click the "START" button. IV-S20 4 Click - The file data is loaded on the set screen. For the following document creation processes after this, see the "4-1 Document creation (IV-S20 parameter)." (See page 4-2 (4) to (6).) 4-3
102 Chapter 4: Document Creation [Example of document creation] Shown below is an example which a document file (with ".csv" extension) that contains the conditions for each object type and can be opened using Excel. <<< Object type number 00 >>> TITLE ---- Main ---- MEAS.0, CAMERA 1 MEAS.0, CAMERA 2 MEAS.1 MEAS.2 MEAS.3 HALT MEAS ON NG POS. ADJ.CAMERA 1 POS. ADJ.CAMERA 2 SAMPLE POSITIONAL DEVIATION MEASUREMENT NO NO NO NO NO NO CALIBRATION NO CALIBRATION IV-S Positional deviation measurement (Camera 1) ---- [MEAS. PROG. COND] * Registration number 0 Mode 2 point search <First point> MEAS WINDOW RECTANGLE REF IMAGE upper left X COORD 68 REF IMAGE upper left Y COORD 232 REF IMAGE lower right X COORD 139 REF IMAGE lower right Y COORD 295 SEARCH AREA upper left COORD 60 SEARCH AREA upper left COORD 224 SEARCH AREA lower right COORD 147 SEARCH AREA lower right COORD 303 DTECT COORD CNTR DTECT COORD (X) 104 DTECT COORD (Y) 264 CONTR. PIXEL 3 <Second point> MEAS WINDOW RECTANGLE REF IMAGE upper left X COORD 356 REF IMAGE upper left Y COORD 232 REF IMAGE lower right X COORD 427 REF IMAGE lower right Y COORD 295 SEARCH AREA upper left COORD 348 SEARCH AREA upper left COORD 224 SEARCH AREA lower right COORD 435 SEARCH AREA lower right COORD 303 DTECT COORD CNTR DTECT COORD (X) 392 DTECT COORD (Y) 264 CONTR. PIXEL 3 DETECT ACCURACY STANDARD 4-4
103 Chapter5: Data Collection Chapter 5: Data Collection You can transmit the measurement result data from the IV-S20 to a personal computer via a communication (general purpose serial I/F), and automatically create a result sheet. The data collection function is used to manage or save measurement data, and collect data settings such as the evaluation conditions. This chapter explains the operation procedures for the data collection. (1) Setting/operation of the IV-S20 1. Set the serial output (input/output conditions) on the IV-S20 to "general purpose serial." On the "MAIN OPS MENU", move the cursor to SET-SCRN, and press the SET key. - On the [SYSTEM SETUP] menu, moves the cursor to item 3 I/O CONDITIONS and press the SET key. I/O CONDITIONS MEAS TRIG INP I/F PARALLEL SERIAL CCD-TRG SERIAL OUTPUT NO PC-LINK SERIAL (INPUT=PARALLEL) CHG MEAS NO.X5,X6NO YES PARALLEL INPUT X5EXT-INP. REG-REF-IMG(MSR0) PARALLEL INPUT X6EXT-INP. CHG-IMG-OUT-CAM OUTPUT STATUS BUSY READY SERIAL CONDITIONS(TO NEXT SUB-MENU) COMPUTER LINK (TO NEXT SUB-MENU) GAIN-OFFSET (TO NEXT SUB-MENU) UPPER MENU 2. Return to the MAIN OPS MENU screen. (2) Communication settings Set the protocols to communicate with the IV-S20. - See the "Chapter 2: Set Communication." (3) Starting the data collection screen Click on the "Data collection" item in the "IV data settings" menu. IV-S20 5 Click here - The "Data collection" dialog box will appear. Continued on the following page 5-1
104 Chapter 5: Data Collection From the previous page (4) File selection Select the "Open" item from the "File" menu on the "Data collection" dialog box. Click here - The "Open" dialog box will appear. - When you want to create a new file (with ".csv" extension) to save the collected data, specify the folder name, enter the file name, and click the "Open" button. If you save the collected data to an existing file, select the file and click the "Open" button. (5) Setting the data collection conditions 1. Click on the "Setup" button. Click here - The setting conditions for the IV-S20 will be loaded. 2. Select the items for data collection. IV-S20 5 Continued on the following page 5-2
105 Chapter5: Data Collection From the previous page (6) Execute a data collection Click on the "START" button. Click here - The data collection from the IV-S20 will start. (7) Creation of a data collection table Click on the "Cancel" button. - The data collection will stop. 2. Click on the "Create a data list" button. - The total file of the data collected will be created automatically. After the creation ends normally, the "Total data creation is complete" message will appear. Note - If processing speed of a personal computer is slower than the data transmission speed of the IV- S20, some parts of the data may be lost. IV-S
106 Chapter 5: Data Collection [Data collection example] Shown below is an example in which the graph creation feature in Excel is used to make a graph of the data file (with ".csv" extension) created with the data collection function. Example: Measuring an area by binary conversion, and setting the upper and lower limits for the evaluation conditions of the surface area. Data file (with ".csv" extension) Create a table using Excel. Create a graph using Excel. Area Frequency Lower limit Upper limit IV-S Series 2 15 NG OK
107 Chapter 6: Reading/Writing Parameters and Images Chapter 6: Reading/Writing Parameters and Images Setting parameters and images (display images/messages) can be stored in a personal computer. Uploading and downloading of the setting parameters is also available. - This function can be used to evaluate samples locally by transmitting setting parameters saved in a file via E- mail or other means of communication. It can be also used to create copies of settings by reading or writing the setting parameters. Ë Loading/saving/verifying setting parameters By selecting the "Load," "Save" or "Verify" item from the "IV data settings" menu, the operations below is available. Setting Section on this Operation items parameters chapter for reference File -> IV Load File -> Set screen 6-3 Set screen -> IV IV -> File Save Set screen -> File 6-1 IV -> Set screen File <-> IV Verify File <-> Set screen 6-2 IV <-> Set screen Ë Read/write image By selecting the "Read image" or "Write image" item from the "File" menu, the operations below is available. Image Read image Write image Operation items Display image (Camera 1) Display image (Camera 2) Message Display image (Camera 1) Display image (Camera 2) Message 6-1 Saving setting parameters Reference section on this chapter 6-4 [1] 6-4 [2] Select the "Save" item from the "IV data settings" menu. The operation item below will appear. IV-S20 6 Save IV -> File Set screen -> File IV -> Set screen Operation details Save the setting parameters of the IV-S20 to the file of the personal computer. Save the setting parameters of the set screen to the file of the personal computer. Save the setting parameters of the IV-S20 to the set screen of the personal computer. 6-1
108 Chapter 6: Reading/Writing Parameters and Images Below describes the operation procedures to save (IV -> File) the IV-S20 setting parameters to the file in the personal computer. (1) Setting/operating of IV-S20 Let the IV-S20 to show the MAIN OPS MENU screen. (2) Communication settings Set the protocols to communicate with the IV-S20. - See "Chapter 2: Set Communication." (3) File selection Click the "Select a file" item from the "IV data settings" menu. Click - The "Open" dialog box will appear. - When you want to create new file (with ".apm" extension) for saving setting parameters, specify the folder name, enter the file name, and click the "Open" button. If you want to save it to an existing file, select the file and click the "Open" button. (4) Saving all parameters 1. Click the "Save" "IV -> File" items from the "IV data settings" menu. Click - The "IV data settings" dialog box will appear. 2. Click the "START" button. IV-S20 6 Click - All setting data in the IV-S20 will be saved to the specified file (enter the file name above.) When the saving is complete, the "IV data settings" dialog box will appear. 3. Click the "OK" button. Click 6-2
109 Chapter 6: Reading/Writing Parameters and Images 6-2 Verifying setting parameters Select the "Verify" item from the "IV data settings" menu. The operation item below will appear. Verify File <-> IV File <-> Set screen IV <-> Set screen Operation details Verify the personal computers file (setting parameters) with the IV-S20 setting parameters. Verify the personal computers file (setting parameters) with the set screen setting parameters. Verify the IV-S20 setting data and the personal computer set screen setting parameters. Below describes the operation procedures to verify (File <-> IV) the PC file with the IV-S20 setting parameters. (1) Setting/operating of IV-S20 Let the IV-S20 to show the MAIN OPS MENU screen. (2) Communication settings Set the protocols to communicate with the IV-S20. - See "Chapter 2: Set Communication." 3) File selection Same as the procedures section See page 6-2. (4) Saving all parameters 1. Click the "Verify" "File <-> IV" items from the "IV data settings" menu. Click - The "IV data settings" dialog box will appear. 2. Click the "START" button on the "IV data settings" dialog box. - All setting data in the IV-S20 and the personal computer specified file will be verified. When the verifying is complete, the "IV data settings" dialog box will appear. Click the "OK" button. IV-S
110 Chapter 6: Reading/Writing Parameters and Images 6-3 Loading setting parameters Select the "Load" item from the "IV data settings" menu. The operation item below will appear. Loading File -> IV File -> Set screen Set screen -> IV Operation details Load the setting parameters from the personal computer s file to the IV-S20. Load the setting parameters from the personal computer s file to the personal computer set screen. Load the setting parameters from the personal computer set screen to the IV-S20. Below describes the operation procedures to load (File <-> IV) the setting parameters from the personal computer s file to the IV-S20. (1) Setting/operating of IV-S20 Let the IV-S20 to show the MAIN OPS MENU screen. (2) Communication settings Set the protocols to communicate with the IV-S20. - See "Chapter 2: Set Communication." (3) File selection Same as the procedures section See page 6-2. (4) Loading all parameters 1. Click the "Load" "File -> IV" items from the "IV data settings" menu. Click IV-S The "IV data settings" dialog box will appear. 2. Click the "START" button on the "IV data settings" dialog box. - The personal computer s specified file (setting parameters) will be loaded to the IV-S20. When the loading is complete, the "IV data settings" dialog box will appear. Click the "OK" button. 6-4
111 Chapter 6: Reading/Writing Parameters and Images 6-4 Reading/writing images [1] Reading images (display images and messages) Select the "Read image" item from the "File" menu. The operation item below will appear. Read image Display image (Camera 1) Display image (Camera 2) Message Operation details Read the display images (camera 1) of the IV-S20 to the personal computer set screen. Read the display images (camera 2) of the IV-S20 to the personal computer set screen. Read the display messages of the IV-S20 to the personal computer set screen. Below describes the operation procedures to read display images (camera 1) of the IV-S20 to the PC set screen and save it to the personal computer s file. (1) Setting/operating of IV-S20 Let the IV-S20 to show the MAIN OPS MENU screen. (2) Communication settings Set the protocols to communicate with the IV-S20. - See "Chapter 2: Set Communication." (3) Loading display images 1. Click the "Read image" "Display images (Camera 1)" items from the "File" menu. Click - The "Read display image (CAM1)" dialog box will appear. IV-S20 6 Continued on the following page 6-5
112 Chapter 6: Reading/Writing Parameters and Images From the previous page 2. Click the "OK" button on the "Read display image (CAM1)" dialog box. - The camera image of the IV-S20 will be transmitted and displayed on the personal computer s image display area. (Example of display) (4) Saving the image as an image file (.bmp format) Click the "Save" "Image only" items from the "File" menu. Click - The "Save as" dialog box will appear. - When you want to create new file (with ".bmp" extension) for saving an image file, specify the folder, enter the file name, and click the "Save" button. If you want to save it to an existing file, select the file and click the "Save" button. - The image file will be stored in the specified file. IV-S
113 Chapter 6: Reading/Writing Parameters and Images [2] Writing images (load images) On the "RUN MENU SETTINGS" menu of the IV-S20, select "NO" in the "CAPTURE AN IMAGE." You can measure using the loaded images from the personal computer. - Transmit the image files over a communication cable to evaluate samples and inspect troubles on remote. - You can process images using the PHOTOSHOP or PAINT SHOP PRO application, and load it to the IV- S20 as a gray scale, 8 bit BMP file. Select the "Write image" item from the "File" menu. The operation item below will appear. Write image Operation details Display image(camera 1) Write the displayed image on the PC to the IV-S20 (camera 1). Display image(camera 2) Write the displayed image on the PC to the IV-S20 (camera 2). Below describes the operation procedures to write displayed images on the PC screen to the IV-S20 (camera 1.) (1) Setting/operating of IV-S20 1. On the "RUN MENU SETTINGS" menu of the IV-S20, select "NO" in the "CAPTURE AN IMAGE."\ On the "MAIN OPS MENU", move the cursor to "SET-SCRN" item, and press the "SET" key. - On the [SYSTEM SEUP] menu, move the cursor to "1 RUN MENU SETTINGS" and press the "SET" key. RUN MENU SETTINGS 1MONITOR OUTPUTCAM1 CAM2 CAM1&2 2CAMERA1&2 CAM1=MD CAM2=MD 3CAPTURE AN IMAGEPARTIAL-IMAGE WHOLE-IMAGE NO 4MESSAGE DISPLAY YES(RESULT.OK) YES(RESULT.NO) NO 5PATTERN DISPLAYMEAS-RESULT- OUT NO 6SHOW BINARY IMAGEYES NO 7 YES NO 8DISPLAY + CURSORNO YES 9OBJ.NO.MANL MODENO YES 0UPPER MENU 2. Let the IV-S20 to show the MAIN OPS MENU screen. (2) Communication settings Set the protocols to communicate with the IV-S20. - See "Chapter 2: Set Communication." IV-S20 6 Continued on the following page 6-7
114 Chapter 6: Reading/Writing Parameters and Images From the previous page (3) Loading display images 1. Click the "Write image" "Display image (Camera 1)" items from the "File" menu. Click - The "Write display image (CAM1)" dialog box will appear. 2. Click the "OK" button on the "Write display image (CAM1)" dialog box. - The image displayed on the PC will be written to the IV-S20 (camera 1). IV-S
115 Chapter 7: Command Test Chapter 7: Command Test The command test function is used to communicate to the IV-S20 through the serial interface and confirm that communication has been established when the personal computer is starting started. This chapter describes the command test procedures. (1) Setting/operating of IV-S20 1. On the "I/O CONDITIONS" menu on the IV-S20, select "SERIAL" in the "SERIAL OUTPUT" item. On the "MAIN OPS MENU", move the cursor to SET-SCRN, and press the SET key. - On the [SYSTEM SETUP] menu, moves the cursor to item 3 I/O CONDITIONS and press the SET key. I/O CONDITIONS 1MEAS TRIG INP I/F PARALLEL SERIAL CCD-TRG 3SERIAL OUTPUT NO PC-LINK SERIAL (INPUT=PARALLEL) 4CHG MEAS NO.X5,X6NO YES 5PARALLEL INPUT X5EXT-INP. REG-REF-IMG(MSR0) 6PARALLEL INPUT X6EXT-INP. CHG-IMG-OUT-CAM 7OUTPUT STATUS BUSY READY 8SERIAL CONDITIONS(TO NEXT SUB-MENU) 9COMPUTER LINK (TO NEXT SUB-MENU) 0GAIN-OFFSET (TO NEXT SUB-MENU) qupper MENU 2. Bring up the MAIN OPS MENU screen. (2) Communication settings Set the protocols for communication with the IV-S20. - See "Chapter 2: Set Communication." (3) Starting the command test screen Click on the "Command Test" item on the "File" menu. Click here - The "Command test" dialog box will appear. IV-S20 7 Continued on the following page 7-1
116 Chapter 7: Command Test From the previous page (4) Setting the conditions for the command test In the "Command test" dialog box, set the conditions for the command test (set time out, checksum, and number of repeats). Setting details 10 sec. Setting the time out 30 sec. 60 sec. Automatic Checksum Number of repeats Manual Fixed 1 time 2 times 3 times Others Description Wait 10 seconds for a response. Wait 30 seconds for a response. Wait 60 seconds for a response. A checksum is automatically created when data is transmitted. An operator counts a checksum, and attach it to a send data directly before transmitting. A checksum is not executed, will be transmitted. The data transmission terminates with one time even a communication error occurs. The data transmitted until twice when a communication error occurs. The data will be transmitted until three times when a communication error occurs. The number of repeats can be set over four times. - The " " indicates the default setting. (5) Transmitting serial commands Enter the data to send in the "Command test" dialog box, and press the [Enter] key or click the "Data transfer" button. - The data will be transmitted to the IV-S20. The response data will be displayed in the receive data area. IV-S20 7 Enter the data Checksum to send values Display the data received Click here Reference: Click the "Data Clear" menu to delete the displays of the sending data, the receiving data, and the checksum values. Continued on the following page Click 7-2
117 Chapter 7: Command Test From the previous page (6) Saving/loading files - Saving the data received to a file 1. Click on the "Select a file" item in the "File" menu. - The "Open" dialog box will appear. - When you want to create a new file (with ".tst" extension) to save the data received, specify the folder name, enter the file name, and click on the "Open" button. If you want to save it to an existing file, select the file and click on the "Open" button. 2. Click on the "Save" item in the "File" menu. - Loading the receiving file from a file 1. Click the "Select a file" item from the "File" menu. - The "Open" dialog box will appear. Select the loading folder or file (with ".tst" extension) name. 2. Click the "Load" item from the "File" menu. IV-S
118 Chapter 8: Upgrade Version Chapter 8: Upgrade Version To upgrade the IV-S20 system version (improved functions) you simplydownload the new version from a personal computer. - The IV-S20 software consists of the "system program," used to set up and execute image processing operations, and a "boot program" to load the other programs. In some cases, both programs need to be upgraded. (Refer to our sales department for the latest version of the system software.) Described below are the procedures for upgrading the program version. (1) Preparation Create the folders below for installing the software. SVXXX.mot VXXX system program (X is different between versions.) BVXXX.mot VXXX boot program (2) Communication settings Set the protocols for communication with the IV-S20. - See "Chapter 2: Set Communication." (3) Setting/operating of IV-S20 1. Turn on the IV-S20. - Turn on the IV-S20, while pressing and holding down both the left key (\) and the set key (SET) on the remote key pad at the same time. Left key (\) Set key (SET) - The IV-S20 upgrade version menu (IVS20 VERSION UP MENU) will appear on the monitor. IVS20 VERSION UP MENU 1SYSTEM RECEIVE RUN 2SYSTEM TRANSFER RUN 3BOOT RECEIVE RUN 4BOOT TRANSFER RUN 5ALL INITIALIZE RUN 6POWER ON RESET RUN 2. Select the upgrade version menu. - Move the up and down keys to select the "1 SYSTEM RECEIVE" item and press the set key (SET). (The "3 BOOT RECEIVE" item may also be needed to perform the upgrade, depending on the upgrade conditions.) 10 IV-S20 8 Continued on the following page 8-1
119 Chapter 8: Upgrade Version From the previous page (4) File selection Click on the "Select a file" item on the "Version up" menu. Click - The "Open" dialog box will appear. - Select the SVXXX.mot file and click on the "Open" button. (5) Transmission Click the "Transfer data Without INIT" item from the "Version up" menu. Click - Transmission is started. - When the [ ON RECEIVE ] message appears on the IV-S20 monitor and the [ ] flashes, the transmission has been successful. - It takes approximately five minuets to transmit the file from a Pentium 266 MHz personal computer. - When the [ ON RECEIVE ] display disappears, the new system program has been successfully written to the flash memory. (6) Starting the g new version of the system Move the up and down keys to select "6 POWER ON RESET" on the IV-S20 upgrade version menu (displayed on the monitor) and press the [SET] key. IVS20 VERSION UP MENU 1SYSTEM RECEIVE RUN 2SYSTEM TRANSFER RUN 3BOOT RECEIVE RUN 4BOOT TRANSFER RUN 5ALL INITIALIZE RUN 6POWER ON RESET RUN 10 IV-S The power to the IV-S20 will be reset and the new version of the system program will start. 8-2
120 Chapter 9: Additional Descriptions Chapter 9: Additional Descriptions This chapter describes additional description; copy to the clipboard, changing the message display color, and changing the image brightness. [1] Copy to the clipboard The displayed images can be copied to the Windows95/98 clipboard. - To paste a display image into an Excel or Word file, click "Paste" on the "Edit" menu of Excel or Word. The image will appear at the cursor in the active document. (Word and Excel are registered trademarks of Microsoft Corporation.) (Operation procedures) 1. Move the cursor to "Copy display image" on the "Edit" menu. 2. Select the object to copy. Click "Image only," "Message only," or "Image + Message." - The object will be copied to the Windows95/98 clipboard. [2] Changing the message display color You can select one of 8 colors for the display image color. If the image and the message are same colors, use a different message color to allow you to see the message. - The colors you can chose from are black, blue, green, cyan, red, magenta, yellow, and white. - If you display images and messages, set the image brightness to "Half," and select a white message display color. Then, you can easily view the screen. - If you are only going to display messages, change message display color to black, so that you can paste the messages to a clipboard or into other documents. (Operation procedures) 1. Move the cursor to "Message color" on the "Edit" menu. 2. Select a color. Select the desired color. (Default: black) - The message color will be changed. IV-S
121 Chapter 9: Additional Descriptions [3] Changing the image brightness You can set the displayed image brightness to "Normal" or "Half." - When you display "Image + Message," select the image brightness to "Half." (Message color is "white.") (Operation procedures) 1. Move the cursor to the "DISP image bright level" item on the "Edit" menu. 2. Select a brightness. - Click on "Normal" or "Half." (Default: Normal ) - The displayed image will be changed to the selected brightness. IV-S
122 Error code If an error occurs and an error code appears while operating the IV-S30SP, use the error code list below for details about the error. Error code Possible cause 7 Not enough memory to perform the save operation. 9 The parameter entered is outside the effective range. 13 The data is not in the status to be able to use. 52 The filename cannot be found. 53 Cannot find the required file. 55 The selected file is already open. 61 There is not enough disc space. 62 There is no more data in the file. 70 Unable to write the data. 71 The disk is not ready. 75 Invalid path name. 380 Incorrect parameter value. 481 Faulty picture. 485 Unacceptable picture format Invalid port number The port is already opened. For information about error codes not listed above, see "Cause and Treatment of a termination code (when an error occurs)" in the user's manual for the IV-S31MX/S32MX/S33MX, or IV-S20). E-1 E
DUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
SA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting
Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration
Table of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions..
Table of Contents 1. Overview..... 3 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3 2. Installation Instructions.. 4 2.1 Installing the On Call Diabetes Management Software. 4 2.2
HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide
HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide Copyright and License 2008 Copyright Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation without prior written
NDA-30141 ISSUE 1 STOCK # 200893. CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000. NEC America, Inc.
NDA-30141 ISSUE 1 STOCK # 200893 CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, 2000 NEC America, Inc. LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications,
Instruction manual. testo easyheat Configuration and Analysis software
Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of
NETWORK PRINT MONITOR User Guide
NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable
13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES
LESSON 13 Managing Devices OBJECTIVES After completing this lesson, you will be able to: 1. Open System Properties. 2. Use Device Manager. 3. Understand hardware profiles. 4. Set performance options. Estimated
Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc.
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started
StrikeRisk v6.0 IEC/EN 62305-2 Risk Management Software Getting Started Contents StrikeRisk v6.0 Introduction 1/1 1 Installing StrikeRisk System requirements Installing StrikeRisk Installation troubleshooting
Trace600 OTDR Test Management Software User s guide
Trace600 OTDR Test Management Software User s guide T e s t & I n s p e c t i o n A Trace600 OTDR Test Management Software User s guide T e s t & I n s p e c t i o n 2002, AFL Telecommunications, all rights
Korosi Monitoring System (KMS) Software Manual
PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
Trace.Net OTDR Test Management Software User s guide
Trace.Net OTDR Test Management Software User s guide 2007-2009, AFL Telecommunications, all rights reserved. TRAC-01-1000 Revision B, 2009-06-10 Specifications are subject to change without notice. I Contents
SHARP Digital Signage Software Pro PN-SS05 OPERATION MANUAL
SHARP Digital Signage Software Pro PN-SS05 Version 4.1 OPERATION MANUAL Contents Introduction... 2 Precautions on Use...2 Trademarks...2 How to Read this Manual...3 Definitions...3 Installing/Launching...
Operating Instructions
Operating Instructions (For Setting Up) Digital Imaging Systems Installation Overview Model No. DP-8060 / 8045 / 8035 Table of Contents Setting Your Machine Installation Overview General Installation Overview...
JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP
AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,
EPSON Scan Server & EPSON TWAIN Pro Network
EPSON Scan Server & EPSON TWAIN Pro Network EPSON Scan Server & EPSON TWAIN Pro Network SCANNER UTILITY PROGRAMS All rights reserved. No part of this publication may be reproduced, stored in a retrieval
OralChroma OralChroma DataManager
OralChroma OralChroma DataManager User s Guide for Windows Version 3.5 Introduction This is a user s manual for the OralChroma DataManager. Copyright Copyright (C) 2008- ABIMEDICAL CORPORATION. All Rights
Software User's Guide
Software User's Guide Brother QL-series The contents of this guide and the specifications of this product are subject to change without notice. Brother reserves the right to make changes without notice
MULTIFUNCTIONAL DIGITAL SYSTEMS. Network Fax Guide
MULTIFUNCTIONAL DIGITAL SYSTEMS Network Fax Guide 2009 KYOCERA MITA Corporation All rights reserved Preface Thank you for purchasing Multifunctional Digital Color Systems. This manual explains the instructions
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Safety Precautions Read and understand this specifications, instruction manual, installation manual and catalog to make proper use of the product. WARNING If critical situations that could lead to user
Using These Manuals. How to Use the. Software User Guide. Display examples: 1. Understanding How to Use Your Camera.
Software User Guide For the safe use of your camera, be sure to read the Safety Precautions thoroughly before use. Types of software installed on your computer varies depending on the method of installation
Table of Contents. INTRODUCTION...v. How to Use This Manual...v Terms Used in this Manual...v Fonts Used in this Manual...v
Table of Contents INTRODUCTION...v How to Use This Manual...v Terms Used in this Manual...v Fonts Used in this Manual...v PC Hardware Requirements...vi Software Installation...vii Installing DataWorker
ActiView. Visual Presenter Image Software User Manual - English
ActiView Visual Presenter Image Software User Manual - English Date: 05/02/2013 Table of Contents 1. Introduction... 3 2. System Requirements... 3 3. Install ActiView - Windows OS... 4 4. Install ActiView
Handheld LPC Utility Software for Windows. Operation Manual
Handheld LPC Utility Software for Windows MODEL S388-70 Operation Manual Read this manual carefully and understand the warnings described in this manual before operating the product. Keep this manual handy
File Management Utility. T u t o r i a l
File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication
SMS (Server Management Software) Digital Video Recorder. User s Manual
SMS (Server Management Software) Digital Video Recorder User s Manual Contents 1 - Introduction 2 1.1 About this manual 2 1.2 Configuration 2 1.3 SMS Functions 2 1.4 Product Information 2 1.5 System Requirements
USB 2.0 VGA ADAPTER USER MANUAL
USB 2.0 VGA ADAPTER USER MANUAL CONTENTS INTRODUCTION... 3 FEATURES... 3 SYSTEM REQUIREMENTS... 3 PACKAGE CONTENTS... 3 SUPPORTED COMMON DISPLAY RESOLUTION... 4 TECHNICAL SPECIFICATIONS... 4 INSTALLATION
Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0
Trantec S5.5 Monitoring Software Manual Initial Setup Minimum PC Requirements 1.6 GHz CPU, 256 MB Memory, 1 available USB port, Windows XP Recommended PC >2.0 GHz CPU, 512 MB (XP) 1 GB (Vista) memory,
Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.
Important Please read this User s Manual carefully to familiarize yourself with safe and effective usage. About ScreenManager Pro for LCD... 3 1. Setting Up... 4 1-1. System Requirements...4 1-2. Installing
PORTABLE DATA COLLECTION TERMINAL
PORTABLE DATA COLLECTION TERMINAL WINDOWS TRANSFER UTILITY HELP FILES BETA EDITION Compsee, Inc. A Subsidiary of McRae Industries, Inc. 2 Welcome Thank you for using the Apex III Windows Transfer Utility
Omron Health Management Software Ver1.3 User s Help Manual
Omron Health Management Software Ver1.3 User s Help Manual Copyright 2006-2008 Omron Healthcare Co., Ltd. World Rights Reserved Visit http://software.omronhealthcare.com to register your customer information
Guide to Using AMS 4.0 Marking Software
Guide to Using AMS 4.0 Marking Software Guide to Using AMS 4.0 Marking Software Contents System Requirements...2 Software Installation...2 Selecting the Output Device and Changing Settings...2 Definitions...
Guide to Installing BBL Crystal MIND on Windows 7
Guide to Installing BBL Crystal MIND on Windows 7 Introduction The BBL Crystal MIND software can not be directly installed on the Microsoft Windows 7 platform, however it can be installed and run via XP
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Document Number: P0874391 Document Release: Standard 1.00 Date: November 1997 Year Publish FCC TM 1997 All rights reserved Printed in
QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay
QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER
Notes: STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER 1. These instructions focus on installation on Windows Terminal Server (WTS), but are applicable
Checking the Package Contents. Installing the Printer Software. Connecting. Unpacking the. the Printer. Printer. Attaching
Installing the Printer Software Checking the Package Contents Connecting the Printer Unpacking the Printer Installing the Ink Cartridges Plugging in the Printer Attaching the Printer Parts 4032216-00 EUL
ZEN-SOFT01-V3. Cat.No.W386-E1-03
ZEN-SOFT01-V3 Cat.No.W386-E1-03 ZEN-SOFT01-V3 ZEN Support Software Operation Manual Revised April 2003 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator
SOFTWARE INSTALLATION INSTRUCTIONS
AUDITGARD LGA Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS Implementation Package The AuditGard Software implementation package includes: 707013 AuditGard Software Install CD 42145 Programming/Audit
DAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts
Rubbermaid Medical Solutions Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts REVISED FEBRUARY 25, 2010 Filename: Cart Interface Installation & Control Board
Operating Instructions
Operating Instructions (For Setting up the Printer Driver and the Panasonic Document Management System) Digital Imaging Systems Model No. DP-800P / 800E / 806P Installation Table of Contents Installation
Event Record Monitoring and Analysis Software. Software Rev. 3.0 and Up. User s Guide
Event Record Monitoring and Analysis Software Software Rev. 3.0 and Up User s Guide 2 Contents Contents Chapter 1: About ERMAWin 4 Chapter 2: Overview 5 About this Manual 5 System Requirements 5 Installing
Contents. Hardware Configuration... 27 Uninstalling Shortcuts Black...29
Contents Getting Started...1 Check your Computer meets the Minimum Requirements... 1 Ensure your Computer is Running in Normal Sized Fonts... 7 Ensure your Regional Settings are Correct... 9 Reboot your
Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents
Page 1 Centran Version 4 Getting Started Guide KABA MAS Kaba Mas Welcome Kaba Mas, part of the world-wide Kaba group, is the world's leading manufacturer and supplier of high security, electronic safe
Manual. Danfoss Central Station Communications Software Version 3
Manual Danfoss Central Station Communications Software Version 3 RS.8A.Q1.02 1-2001 Contents Introduction 4 System Overview 4 Minimum and Recommended Hardware Requirements 4 Using the Keyboard to Select
How To Install A Scanner On A Computer With A Microsoft Scanner On Itunes Vista 2 (Windows) (Windows 2000) (Powerbook) (Macintosh) (Apple) (X86) (Ms7000) (Netbook
MS6000 MKII / MS7000 MKII User s Guide Scanner Driver Software Ver.3.00 Scanner Driver (32bit) Ver.2.26 Scanner Driver (64bit) Ver.3.16 Contents 1 Getting Ready 1-1 1-1 Overview 1-1 1-2 System Requirements
QIAsymphony Management Console User Manual
April 2012 QIAsymphony Management Console User Manual For use with software version 4.0 Sample & Assay Technologies Trademarks QIAGEN, QIAsymphony, Rotor-Gene (QIAGEN Group). InstallShield (Informer Technologies,
Temperature Controller Support Software
Temperature Controller Support Software CX-Thermo Ver.4.0 Online Help Contents Chapter 1 Introduction 1.1 What is CX-Thermo? 1.2 Compatible Device Models and Computers 1.3 Hardware Setups 1.4 Basic Use
Config software for D2 systems USER S MANUAL
DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------
Quick Start Using DASYLab with your Measurement Computing USB device
Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC). This Quick Start document contains
WindO/I-NV2 Utility Pass-Through Tool
B-1159(3) WindO/I-NV2 Utility Pass-Through Tool Instruction Manual Introduction This instruction manual explains the operation and handling of the WindO/I-NV2 Utility Pass-Through Tool. Before using the
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
Ultra Thin Client TC-401 TC-402. Users s Guide
Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE
USER S MANUAL USB FILE TRANSFER CABLE
1. Introduction USER S MANUAL USB FILE TRANSFER CABLE Congratulations on your purchase of the PC-Linq, an USB file transfer cable. This unique cable allows you to easily connect two computers with USB
DVR4C Remote Viewer Operation Manual Table of Contents EN 3 1. OVERVIEW...5 1.1 MINIMUM PC REQUIREMENTS...5 2. INSTALLING THE PROGRAM...
DVR4x4RemoteViewer.book Page 3 Tuesday, February 15, 2005 9:19 AM DVR4C Remote Viewer Operation Manual Table of Contents EN 3 1. OVERVIEW...5 1.1 MINIMUM PC REQUIREMENTS...5 2. INSTALLING THE PROGRAM...5
FANUC Open CNC. Setup procedure for Windows 95/NT 4.0
Setup procedure for Windows 95/NT 4.0 1. Overview When Microsoft s operating system, Windows 95(both Japanese and English version) and Windows NT Workstation 4.0(both Japanese and English version), are
Moxa Device Manager 2.0 User s Guide
First Edition, March 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa Device Manager 2.0 User Guide The software described in this manual
With the purchase of ONSSI NetDVMS you have chosen an extremely powerful and intelligent surveillance solution.
Dear ONSSI Customer, With the purchase of ONSSI NetDVMS you have chosen an extremely powerful and intelligent surveillance solution. This Getting Started Administrator Guide will explain how to install
PN-T321 LCD MONITOR. USB Flash Drive Media Tool OPERATION MANUAL
PN-T321 LCD MONITOR USB Flash Drive Media Tool OPERATION MANUAL Contents Introduction...2 Installing/Uninstalling the Software...3 System Requirements...3 Installing the Software...3 Uninstalling...3 Using
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
Table Of Contents. System Monitoring... 14 System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...
Quick Start Table Of Contents Getting Started... 2 NEware Editions...2 Installing NEware...3 Installing Languages...3 Connecting to NEware...3 Changing Your IP100 Password...4 User Codes... 5 Master Feature...5
Control Technology Corporation CTC Monitor User Guide Doc. No. MAN-1030A Copyright 2001 Control Technology Corporation All Rights Reserved Printed in USA The information in this document is subject to
ScanWin Installation and Windows 7-64 bit operating system
ScanWin Installation and Windows 7-64 bit operating system In order to run the ScanWin Pro install and program on Windows 7 64 bit operating system you need to install a Virtual PC and then install a valid,
Network FAX Driver. Operation Guide
Network FAX Driver Operation Guide About this Operation Guide This Operation Guide explains the settings for the Network FAX driver as well as the procedures that are required in order to use the Network
COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS
COMBOGARDPRO 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS IMPLEMENTATION PACKAGE The ComboGard Pro Software implementation package includes: 707012 ComboGard Pro Software Install
General Precautions The user must operate each product according to the performance specifications described in the operation manuals.
General Precautions The user must operate each product according to the performance specifications described in the operation manuals. Before using the product under conditions which are not described
Compaq Presario MyMovieSTUDIO. Getting Started
Compaq Presario MyMovieSTUDIO Getting Started Congratulations and welcome to the Compaq Presario MyMovieSTUDIO leading edge digital video editing and DVD authoring desktop computer. You ve purchased a
PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1
PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL Version 2.1 Contents Setting up the PC...3 Installing the touch panel driver...3 Touch Panel Settings...4 How to configure settings...4 Calibration...5
Driver Installation (USB 2.0) and Software configuration manuals for Sopro Imaging, EagleSoft, and Dentrix Image 4.5
Driver Installation (USB 2.0) and Software configuration manuals for Sopro Imaging, EagleSoft, and Dentrix Image 4.5 124 Gaither Drive - Suite 140 - Mount Laurel, NJ 08054 USA Tel: 800-289-6367 Fax: 856-222-4726
NVMS - 1000 USER MANUAL. Version 2.1.0
NVMS - 1000 USER MANUAL Version 2.1.0 Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall
Analyzer 2.0. Installation Guide. Contents
Analyzer 2.0 Analyzer 2.0 is a comprehensive suite of tools designed to help you analyze complex aqueous and multisolvent electrolyte solution chemistry, thermophysical properties, phase behavior and corrosion
PRINTER DRIVER GUIDE (KODAK 305 Photo Printer)
PRINTER DRIVER GUIDE () Microsoft, Windows, Windows XP, Windows Vista and Windows 7 are registered trademarks of Microsoft Corporation in the United States and/or other countries. Adobe, Adobe Photoshop
Coyote SP - Installation Notes
Step 1 - Setup E-mail Support: Coyote SP - Installation Notes Coyote SP Installation Steps 1) Insert the Coyote SP installation CD. 2) Follow Setup Instructions. 2) If Setup won t appear, click Windows
DATA PROJECTOR XJ-A135/XJ-A145/XJ-A235/ XJ-A245
DATA PROJECTOR XJ-A135/XJ-A145/XJ-A235/ XJ-A245 E Data Projector Wireless Function Guide Be sure to read the precautions in the User s Guide (Basic Operations) that comes with the Data Projector. Be sure
DATA PROJECTOR XJ-A146/XJ-A246/XJ-A256
DATA PROJECTOR XJ-A146/XJ-A246/XJ-A256 E Data Projector Wireless Function Guide Be sure to read the precautions in the Setup Guide that comes with the Data Projector. Be sure to keep all user documentation
EasyMP Monitor Operation Guide Ver.4.40
EasyMP Monitor Operation Guide Ver.4.40 2 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Caution q s Indicates procedures
WebEx Remote Access User s Guide
About This Guide This guide introduces you to WebEx Remote Access and its features. This guide assumes that you have a user account for your Remote Access service. Note To obtain a user account, contact
MULTIFUNCTIONAL DIGITAL SYSTEMS. Operator's Manual for TWAIN Driver/File Downloader
MULTIFUNCTIONAL DIGITAL SYSTEMS Operator's Manual for TWAIN Driver/File Downloader 2008 KYOCERA MITA Corporation All rights reserved Preface Thank you for purchasing KYOCERA MITA Multifunctional Digital
History of Revisions. Ordering Information
No part of this document may be reproduced in any form or by any means without the express written consent of II Morrow Inc. II Morrow, Apollo, and Precedus are trademarks of II Morrow Inc. Windows is
Chapter 1 Downloading Images to Your Computer (Windows)
Software User Guide For the safe use of your camera, be sure to read the Safety Precautions thoroughly before use. Types of software installed on your computer varies depending on the method of installation
Screen Capture. User s Guide. For ClassPad Series. http://edu.casio.com. http://edu.casio.com/products/classpad/ http://edu.casio.
For ClassPad Series E Screen Capture User s Guide CASIO Education website URL http://edu.casio.com ClassPad website URL http://edu.casio.com/products/classpad/ ClassPad register URL http://edu.casio.com/dl/
IMPORTANT! CPD 8424R1
IMPORTANT! You need to reinstall EPSON Image Authentication System (IAS) on your camera if it was installed before your camera was repaired. Please see your EPSON Image Authentication System User s Guide
Avery Dennison UK Consumer Helpline: 0800 80 50 20 Consumer email: [email protected]
Avery DesignPro for PC Frequently Asked Questions General Information Questions Q: What are the system requirements for DesignPro? A: The following is required to run DesignPro: Microsoft Windows VistaTM,
DTAP3000 DTSX3000 Control Visualization Software LAS2.0 Data Conversion Guide
User s Manual DTAP3000 DTSX3000 Control Visualization Software LAS2.0 Data Conversion Guide 1st Edition Blank Page < Introduction > i Introduction About this Manual Thank you for purchasing the DTSX3000
How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini
EasyMP Network Projection Operation Guide Contents 2 Before Use Functions of EasyMP Network Projection....................... 5 Sharing the Projector....................................................
Model 288B Charge Plate Graphing Software Operators Guide
Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254
e-dpp 4.0.2 May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database
e-dpp 4.0.2 May 2013 Microsoft Windows 2003 Server, XP, Vista, 7 Access Database ELTECHS Engineering and Consulting Co., Ltd., Japan www.eltechs.co.jp Tel No. +81 (47) 490-1010 Fax No. +81 (47) 490-1011
Addendum Advanced POS Printer Drivers
Addendum Advanced POS Printer Drivers Overview With the introduction of version 4.0, The General Store now supports the use of advanced, manufacturer s printer drivers for certain point of sale printers.
ACS CLIENT SOFTWARE USER MANUAL
ACS CLIENT SOFTWARE USER MANUAL 1 ACS USER GUIDE 1.1 System Requirement Recommended System Requirement OS CPU VGA RAM HDD WindowXP, Vista Pentium 4, 2Ghz 1024*768, 64MB 24bit color graphic card 1GB 20MB
User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version 1.23.01
User's Guide Using RFDBManager For 433 MHz / 2.4 GHz RF Version 1.23.01 Copyright Notice Copyright 2005 Syntech Information Company Limited. All rights reserved The software contains proprietary information
LOREX CLIENT Remote Software 4.0
LOREX CLIENT Remote Software 4.0 Instruction Manual English Version 2.0 MODEL: L20WD800 Series www.lorexcctv.com Copyright 2008 LOREX Technology Inc. Table of Contents Table of Contents Software Installation...
1 ImageBrowser Software User Guide
1 ImageBrowser Software User Guide Table of Contents (1/2) Chapter 1 Try It! ImageBrowser Chapter 2 What is ImageBrowser? Chapter 3 Starting ImageBrowser... 4 Downloading Images to Your Computer... 9 Printing
BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL 086-333
ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL 086-333 BIODEX Biodex Medical Systems, Inc. 20 Ramsey Road, Shirley, New York, 11967-4704, Tel: 800-224-6339