THE DURHAM COMPANY TABLE OF CONTENTS

Size: px
Start display at page:

Download "THE DURHAM COMPANY TABLE OF CONTENTS"

Transcription

1 TABLE OF CONTENTS Meter Sockets & Enclosures Single Position Meter Sockets Multiple Position Meter Sockets Transformer Rated Meter Sockets Transockets Meter Socket Knock-out Configuration Charts Test Switches Current Transformer Enclosures Socket Breaker Combinations Socket Breaker Combination Units Socket Breaker Transfer Switch with Metering Provision Socket Breaker Knock-out Configuration Charts Socket Switch Combinations Meter Socket Transfer Switches Transfer Switch Enclosures Meter Socket Pad Mount Transfer Switches Meter Socket Pad Mounted Transfer Switch Burial Sleeves Breaker or Switch Enclosures Breaker Enclosures Breaker Transfer Switch Enclosures without Metering Provisions Breaker or Transfer Switch Enclosures Knock-out Configuration Charts Metering Pedestals Meter Pedestals Transformer Rated Meter Pedestals Connection Pedestals Secondary Connection Pedestals Primary Sectionalizing Pedestals Sectionalizing Pedestals Sectionalizing Pedestal Burial Sleeves Primary Equipment Enclosures Primary Equipment Enclosures (Transclosures) Primary Metering Enclosures Primary Metering Enclosures Primary Fused Sectionalizing Cabinets Accessories Meter Socket Accessories Replacement Breakers Meter Socket Option Codes Wiring Diagrams S, 4S, 5S, 6S, 8S, 9S Meter Forms

2 THE DURHAM COMPANY ALPHA NUMERIC INDEX CATALOG# PG# CATALOG# PG# CATALOG# PG# F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F A 28 I 17216ABC B BBC C CBC D DBC E EBC F FBC G GBC H HBC J JBC K KBC F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F-40 26

3 THE DURHAM COMPANY ALPHA NUMERIC INDEX CATALOG# PG# CATALOG# PG# CATALOG# PG# F F F F F F F F F F F F F F F F F F F F F F F F F F F RDR RDW SFR SFW RDR RDW SFR SFW F F F F F F F H H H R R R RP RDR RDW SFR SFW RDR RDW SFR SFW DDR DDW RDR RDW SFR SFW B RDR RDW SFR SFW DDR DDW RDR RDW SFR SFW 32 3H H H R R R RDR RDW DDR DDW SFR SFW DDR DDW SFR SFW SFR SFW DDR DDW SFR SFW 32 4H H II 4H R R R H H H R R R H H H R R R BC FC BC FC BC BC-CL FC FC-CL BC FC 28 A RDR 31 A RDW 31 A SFR 32 A SFW 32 A RDR 31 A RDW 31 A SFR 32 A SFW 32 A RDR 31 A RDW 31 A SFR 32 A SFW 32 A RDR 31 A RDW 31 A SFR 32 A SFW 32 A DDR 33 A DDW 33 A RDR 31 A RDW 31 A SFR 32 A SFW 32 A RDR 31

4 THE DURHAM COMPANY ALPHA NUMERIC INDEX CATALOG# PG# CATALOG# PG# CATALOG# PG# A RDW 31 A SFR 32 A SFW 32 A DDR 33 A DDW 33 A RDR 31 A RDW 31 A SFR 32 A SFW 32 A RDR 31 A RDW 31 A DDR 33 A DDW 33 A SFR 32 A SFW 32 A DDR 33 A DDW 33 A SFR 32 A SFW 32 A DDR 33 A DDW 33 A SFR 32 A SFW 32 A DDR 33 A DDW 33 A SFR 32 A SFW 32 AF3120S2L20 78 AF3120S2M20 78 AF3122S2L20 78 AF3122S2L22 78 AF3122S2M20 78 AF3122S2M22 78 AM AM AM AM AM AM AM AM AM AM AM AM AM AM AM D 68 AM AM AM D 68 AM AM AM APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP APMP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP III ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP ARP AT AT AT AT AT AT AT AT AT AT AT AT AT AT ATB ATB ATB ATB ATB

5 THE DURHAM COMPANY ALPHA NUMERIC INDEX CATALOG# PG# CATALOG# PG# CATALOG# PG# ATB ATB ATB ATB ATB ATB ATB ATB ATB ATBP ATBP ATBP ATBP ATBP ATBP ATBP ATBP ATBP ATBP ATBP ATBP ATBP ATBP ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPL ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATBPR ATP ATP ATP ATP ATP ATP ATP ATP ATP ATP ATP ATP ATP ATP B114DT B114DT50 55 B204DT B204DT50 55 C222N1 37 C222W1 37 C242W1 37 C262W1 37 CB242W0 54 CB262W0 54 CB542W0 54 CB562W0 54 DC222W1 37 DH122N0 36 DH122W0 36 DP122N0 36 DP122W0 36 DRH122N0 36 DRH122W0 36 DRP122N0 36 DRP122W0 36 GS182422F 69 GS182615F 69 GS182618F 69 GS183015F 69 GS183018F 69 GS183022F 69 GS184815F 69 GS186015F 69 GS186018F 69 GS186418F 69 GS186622F 69 GS202422W 69 IV GS202615W 69 GS202618W 69 GS203015W 69 GS203018W 69 GS203022W 69 GS204815W 69 GS206015W 69 GS206018W 69 GS206418W 69 GS206622W 69 H122N0 36 H H H H H H H H H H4320A 8 H H H H H H H H H H H H H H H H H H H H H H H H H H H H7320A 8

6 THE DURHAM COMPANY ALPHA NUMERIC INDEX CATALOG# PG# CATALOG# PG# CATALOG# PG# H H H HC364W1T 38 MP MP MP320C MP320S 62 MP400C MP400NC MP400NS 62 MP400S 62 MPC4 60 MPC5 60 MPC7 60 MPE13 63 MPE13N 63 MPE5 63 MPE5N 63 MPE6 63 MPE6N 63 MPE7 63 MPE7N 63 MPE8 63 MPE8N 63 MPH4 60 MPH5 60 MPH7 60 MPO13 63 MPO13N 63 MPO5 63 MPO5N 63 MPO6 63 MPO6N 63 MPO7 63 MPO7N 63 MPO8 63 MPO8N 63 MPOR13 63 MPOR13N 63 MPOR5 63 MPOR5N 63 MPOR6 63 MPOR6N 63 MPOR7 63 MPOR7N 63 MPOR8 63 MPOR8N 63 P120N0 36 P140W0 36 P711S260W1 59 P711S262W1 59 P722S260W1 59 P722S262W1 59 PCV210DT 48 PCV211DT 48 PCV212DT 48 PCV223DT 49 PCV233DT 49 PCV310DT 48 PCV410DT 48 PCV423DT 49 PCV610DT 48 PCV623DT 49 PD PD PD PD PD PD PDMS PDMS R R N 14 R R6821-7N 14 R R6821-8N 14 R R6851-5N 14 R R6851-6N 14 RC222N1 37 RC222W1 37 RC242W1 37 RC262W1 37 RDC222W1 37 RH122N0 36 RP120N0 36 RP140W0 36 RP R-RS101 2 R-RS111 2 R-RS202 3 R-RS212 3 R-RS213 3 RS101 2 RS111 2 V RS202 3 RS212 3 RS213 3 RS RS220-3A 4 RS220A 4 RS223A 4 RS230 4 RS RS233 4 RSTL RSTL RSTL RSTL RSTS RSTS RSTS RSTS SB114DT SB114DT50 40 SB204DT SB204DT50 40 SBG SBG SBG SBG SBG SBG SBG SBG SBG SBG SSV110DT 43 SSV113DT 44 SSV210DT 43 SSV210DTSS-A 45 SSV211DT 43 SSV211DTSS-A 45 SSV212DTSS-A 45 SSV213DT 44 SSV213DTSS-A 46 SSV233DT 44 SSV233DTSS-A 46 SSV310DT 43 SSV310DTSS-A 45 SSV410DT 43 SSV410DTSS-A 45 SSV423DT 44 SSV423DTSS-A 46

7 THE DURHAM COMPANY ALPHA NUMERIC INDEX CATALOG# PG# SSV610DT 43 SSV610DTSS-A 45 SSV623DT 44 SSV623DTSS-A 46 STL STL STL STL STL STL STL STL STS STS STS STS STS STS STS STS SV110DT 47 SV113DT 47 SV210DT 47 SV213DT 47 SV410DT 47 SV413DT 47 SV610DT 47 SV613DT 47 TSB TSB TSBN TSBN TSDF1334U 18 TSSC1332U 18 UHC344N3T 38 UHC344N5T 38 VI

8 METER SOCKET FAMILY 1

9 METER SOCKETS 125 AMPERE RING & RINGLESS 4 & 5 TERMINAL UT-RS101B UT-RS111B CATALOG NUMBER CABINET DIMENSIONS KNOCKOUT WIRE SIZE RINGLESS RING HEIGHT WIDTH DEPTH CONFIGURATION CU-AL RS101(*) R-RS101(*) 10 7/ /2 Fig. 1 #8-2/0 RS111(*) R-RS111(*) /8 Fig. 2 #8-2/0 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number in the following manner, UT-RS101B. Add prefix G for factory installed, grounded 5th terminal. Add prefix T for ground wire connector (#14-#2 CU/AL). Add prefix Z for hex head connectors line, load, and neutral. Ring style sockets are supplied with snap-type sealing rings. UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 K 1 1/4 L 1 1/2 M 2 N 2 1/2 P 2

10 METER SOCKETS 200 AMPERE RING & RINGLESS 4 & 5 TERMINAL UT-RS202B UT-RS213B UT-RS213-8C CATALOG NUMBER CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL RINGLESS RING HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD RS202(*) R-RS202(*) /8 Fig. 3 #8-250 #8-250 RS212(*) R-RS212(*) /8 Fig. 2 #8-250 #8-250 RS213(*) R-RS213(*) /8 Fig. 2 #8-350 #8-350 RS213-8(*) /16 Fig. 4 #8-350 (2) #8-250 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number in the following manner, T-RS202B. Add prefix G for factory installed, grounded 5th terminal. Add prefix T for ground wire connector (#14-#2 CU/AL). Ring style sockets are supplied with snap-type sealing rings. UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your local manufacturer s agent for special units or nonstandard options. 3 HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 1/4 L 1 1/2 M 2 N 2 1/2 P

11 OFFSET METER SOCKETS 200 AMPERE RINGLESS 4 & 5 TERMINAL UT-RS220A UT-RS223A OFFSET STYLE CATALOG NUMBER CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL RINGLESS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD RS220A 14 1/ /16 Fig. 5 3/8 Stud 3/8 Stud RS220-3A 14 1/ /16 Fig. 5 3/8 Stud #8-350 RS223A /16 Fig. 5 #8-350 #8-350 RS230(*) 18 5/ /16 Fig. 5 3/8 Stud 3/8 Stud RS230-3(*) 18 5/ /16 Fig. 5 3/8 Stud #8-350 RS233(*) 17 1/ /16 Fig. 5 #8-350 #8-350 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number in the following manner, T-RS202B. Add prefix G for factory installed, grounded 5th terminal. Add prefix T for ground wire connector (#14-#2 CU/AL). UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 1/4 L 1 1/2 M 2 N 2 1/2 P 4

12 METER SOCKETS 200 AMPERE RINGLESS 4, 5, & 7 TERMINAL LEVER BYPASS W/JAW RELEASE UT-H4203B UT-H7210T UT-H7213T CATALOG # OF CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER JAWS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD H4203(*) /2 4 15/16 Fig. 6 #6-350 #6-350 H4210(*) / /16 Fig. 7 3/8 stud 3/8 stud H4213(*) /16 Fig. 7 #6-350 #6-350 H5203(*) /2 4 15/16 Fig. 6 #6-350 #6-350 H5210(*) / /16 Fig. 7 3/8 stud 3/8 stud H5213(*) /16 Fig. 7 #6-350 #6-350 H7203(*) /2 4 15/16 Fig. 6 #6-350 #6-350 H7210(*) / /16 Fig. 7 3/8 stud 3/8 stud H7213(*) /16 Fig. 7 #6-350 #6-350 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number. Add prefix G for factory installed, grounded 5th terminal. Add prefix T for ground wire connector (#14-#2 CU/AL). UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. HUB SELECTION CHART HUB OR TOP CONFIGURATION CATALOG SUFFIX HUB OR TOP CONFIGURATION CATALOG SUFFIX SOLID A SOLID A FOR HUB(SM) B FOR HUB(LG) T HCP(SM) C HCP(LG) U 1 1/4 (SM) L 2 1/2 (LG) V 1 1/2 (SM) M 3 (LG) Q 2 (SM) N 3 1/2 (LG) R 2 1/2 (SM) P 4 (LG) S Contact factory or your local manufacturer s agent for special units or nonstandard options. 5

13 OFFSET METER SOCKETS 200 AMPERE RINGLESS 4, 5 & 7 TERMINAL LEVER BYPASS W/JAW RELEASE UT-H7233U UT-H4230C OFFSET STYLE CATALOG # OF CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER JAWS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD H4230 (*) /8 Fig. 8 3/8 Stud 3/8 Stud H4233(*) /8 Fig. 8 #6-350 #6-350 H5230(*) /8 Fig. 8 3/8 Stud 3/8 Stud H5230-3(*) /8 Fig. 8 3/8 Stud #6-350 H5233(*) /8 Fig. 8 #6-350 #6-350 H7230(*) /8 Fig. 8 3/8 Stud 3/8 Stud H7230-3(*) /8 Fig. 8 3/8 Stud #6-350 H7233(*) /8 Fig. 8 #6-350 #6-350 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number. Add prefix T for ground wire connector (#14-#2 CU/AL). UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION CATALOG SUFFIX HUB OR TOP CONFIGURATION CATALOG SUFFIX SOLID A SOLID A FOR HUB(SM) B FOR HUB(LG) T HCP(SM) C HCP(LG) U 1 1/4 (SM) L 2 1/2 (LG) V 1 1/2 (SM) M 3 (LG) Q 2 (SM) N 3 1/2 (LG) R 2 1/2 (SM) P 4 (LG) S 6

14 METER SOCKETS 320 AMPERE RINGLESS 4, 5, & 7 TERMINAL LEVER BYPASS W/JAW RELEASE UT-H4300T UT-H5308U UT-H7300T CATALOG # OF CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER JAWS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD H4300(*) / /16 Fig. 9 3/8 Stud 3/8 Stud H4306(*) / /16 Fig. 9 #4-600 #4-600 H4308(*) / /16 Fig. 9 (2) #6-250 #6-250 H4309(*) / /16 Fig. 9 (2) #6-350 #6-350 H5300(*) / /16 Fig. 9 3/8 Stud 3/8 Stud H5306(*) / /16 Fig. 9 #4-600 #4-600 H5308(*) / /16 Fig. 9 (2) #6-250 (2) #6-250 H5309(*) / /16 Fig. 9 (2) #6-350 (2) #6-350 H7300(*) / /16 Fig. 10 3/8 Stud 3/8 Stud H7306(*) / /16 Fig. 10 #4-600 #4-600 H7308(*) / /16 Fig. 10 (2) #6-250 (2) #6-250 H7309(*) / /16 Fig. 10 (2) #6-350 (2) #6-350 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number. Add prefix T for ground wire connector (#14-#1/0 CU/AL). UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION FOR HUB(LG) HCP(LG) 3 (LG) CATALOG SUFFIX T U Q 3 1/2 (LG) R 4 (LG) S 7

15 OFFSET METER SOCKETS 320 AMPERE RINGLESS 4,5,7 TERMINAL LEVER BYPASS W/JAW RELEASE UT-H4320A UT-H4336-9T UT-H7330U OFFSET STYLE CATALOG # OF CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER JAWS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD H4320A /16 Fig. 11 3/8 Stud 3/8 Stud H4330(*) / /16 Fig. 11 3/8 Stud 3/8 Stud H4336(*) / /16 Fig. 11 #4-600 #4-600 H4336-9(*) / /16 Fig. 11 #4-600 (2)#6-350 H4338(*) /16 Fig. 11 (2) #6-250 (2) #6-250 H4339(*) / /16 Fig.11 (2) #6-350 (2) #6-350 H4340(*) / /16 Fig. 11 3/8 Stud 3/8 Stud H5330(*) / /2 Fig. 12 3/8 Stud 3/8 Stud H7320A /2 Fig. 12 3/8 Stud 3/8 Stud H7330(*) / /2 Fig. 12 3/8 Stud 3/8 Stud H7336-9(*) / /2 Fig. 12 #4-600 (2)#6-350 H7339(*) / /2 Fig. 12 (2)#6-350 (2)#6-350 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number. Add prefix T for ground wire connector (#14-#2 CU/AL). UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION FOR HUB(LG) HCP(LG) 3 (LG) CATALOG SUFFIX T U Q 3 1/2 (LG) R 4 (LG) S 8

16 GANG METER SOCKET FAMILY 9

17 GANG METER SOCKETS 100 AMPERE RING & RINGLESS 4 & 5 TERMINAL M S UT-3R1121B UT-3R1421B CENTER FEED CATALOG # OF CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER POSITIONS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD 2R1121(*) /8 24 5/16 4 1/2 Fig. 13 #6-250 #8-2/0 3R1121(*) / /32 4 1/2 Fig. 13 #6-250 #8-2/0 4R1121(*) /8 40 5/8 4 1/2 Fig. 13 #6-250 #8-2/0 5R1121(*) / /32 4 1/2 Fig. 13 #6-250 #8-2/0 6R1131(*) / /16 4 1/2 Fig. 13 #6-350 #8-2/0 END FEED CATALOG # OF CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER POSITIONS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD 2R1421(*) /8 20 5/32 5 3/8 Fig. 14 #6-250 #8-2/0 3R1421(*) /8 28 5/16 5 3/8 Fig. 14 #6-250 #8-2/0 4R1421(*) / /32 5 3/8 Fig. 14 #6-250 #8-2/0 5R1421(*) /8 44 5/8 5 3/8 Fig. 14 #6-250 #8-2/0 6R1431(*) / /32 5 3/8 Fig. 14 #6-350 #8-2/0 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number in the following manner, UT-2R1121B. Add prefix G for factory installed, grounded 5th terminal. Add prefix T for ground wire connector. UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your nearest manufacturer s agent for special units or nonstandard options. 10 HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 1/4 L 1 1/2 M 2 N 2 1/2 P

18 M S THE DURHAM COMPANY GANG METER SOCKETS 200 AMPERE RING & RINGLESS 4 & 5 TERMINAL UT-3R2332T CENTER FEED CATALOG # OF DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER POSITIONS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD 2R2332(*) /8 24 5/16 5 3/8 Fig. 15 #6-350 # R2332(*) / /32 5 3/8 Fig. 15 #6-350 # R2352(*) /8 40 5/8 5 3/8 Fig. 15 1/0-500 # R2392(*)(*) / /32 5 3/8 Fig. 16 +(2)1/0-500 # R2392(*)(*) / /16 5 3/8 Fig. 16 +(2)1/0-500 #8-250 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. (+) Has provisions for (2) 1/0-350 as well. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number in the following manner, U-2R2332T. Add prefix G for factory installed, grounded 5th terminal. Add prefix T for ground wire connector. UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB(LG) HCP(LG) CATALOG SUFFIX A T U 2 1/2 (LG) V 3 (LG) Q 3 1/2 (LG) R 4 (LG) S 11

19 GANG METER SOCKETS 200 AMPERE RINGLESS 4, 5 & 7 TERMINAL LEVER BYPASS W/JAW RELEASE 3H42353U 3H72353T CATALOG # OF # OF CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER POSITIONS JAWS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD 2H42353(*) / /32 6 Fig. 17 1/0-500 # H42353(*) / /8 6 Fig. 17 1/0-500 # H42393(*)(*) / Fig. 18 (2) 1/0-500 # H42393(*)(*) / /8 6 Fig. 18 (2) 1/0-500 # H42393(*)(*) / /32 6 Fig. 18 (2) 1/0-500 # H52353(*) / /32 6 Fig. 17 1/0-500 # H52353(*) / /8 6 Fig. 17 1/0-500 # H52393(*)(*) / Fig. 18 (2) 1/0-500 # H52393(*)(*) / /8 6 Fig. 18 (2) 1/0-500 # H52393(*)(*) / /32 6 Fig. 18 (2) 1/0-500 # H72353(*) / /32 6 Fig. 17 1/0-500 # H72353(*) / /8 6 Fig. 17 1/0-500 # H72393(*)(*) / Fig. 18 (2) 1/0-500 # H72393(*)(*) / /8 6 Fig. 18 (2) 1/0-500 # H72393(*)(*) / /32 6 Fig. 18 (2) 1/0-500 #6-350 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number. Add prefix T for ground wire connector. UL (Underwriters Laboratories) label available on most units. Add prefix U for U.L. label. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB(LG) HCP(LG) 3 (LG) CATALOG SUFFIX A T U Q 3 1/2 (LG) R 4 (LG) S 12

20 INSTRUMENT RATED SOCKET FAMILY 13

21 METER SOCKETS TRANSFORMER RATED RING STYLE 5, 6, 7, 8, & 13 TERMINAL R6851-5B R B CATALOG NON- AUTO # OF CABINET DIMENSIONS KNOCKOUT METER CIRCUIT CIRCUIT NUMBER CLOSING CLOSING JAWS HEIGHT WIDTH DEPTH CONFIGURATION FORM R6851-5(*) X 5 9 1/ /2 Fig. 19 3S R6851-5N-(*) X 5 9 1/ /2 Fig. 19 3S, 12S R6851-6(*) X 6 9 1/ /2 Fig. 19 4S R6851-6N-(*) X 6 9 1/ /2 Fig. 19 4S CATALOG NON- AUTO # OF CABINET DIMENSIONS KNOCKOUT METER CIRCUIT CIRCUIT NUMBER CLOSING CLOSING JAWS HEIGHT WIDTH DEPTH CONFIGURATION FORM R6821-7(*) X /8 Fig S, 15S, 16S, 17S R6821-7N-(*) X /8 Fig. 20 7S, 24S, 14S, 15S, 16S, 17S R6821-8(*) X /8 Fig. 20 5S R6821-8N-(*) X /8 Fig. 20 5S R (*) X /8 Fig. 20 6S, 8S, 9S, 10S R N-(*) X /8 Fig. 20 6S, 8S, 9S, 10S (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Voltage rating of all units is 300 Volts AC RMS. Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number. Ground wire connector (#14-#2 CU/AL) supplied. UL (Underwriters Laboratories) label available. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 K 1 1/4 L 1 1/2 M 2 N 2 1/2 P 14

22 METER SOCKETS TRANSFORMER RATED RINGLESS & RING 5, 6, 8, & 13 TERMINAL STL8-1K Note: Provision for Test Switch STL13-2B CATALOG NUMBER # OF CABINET DIMENSIONS KNOCKOUT 1-PIECE RINGLESS RING JAWS HEIGHT WIDTH DEPTH CONFIGURATION COVER ST(**)5-1(*) /64 Fig. 21 X ST(**)6-1(*) /64 Fig. 21 X ST(**)8-1(*) /64 Fig. 21 X ST(**)13-1(*) /64 Fig. 21 X ST(**)5-2(*) RST(**)5-2(*) /64 Fig. 21 X ST(**)6-2(*) RST(**)6-2(*) /64 Fig. 21 X ST(**)8-2(*) RST(**)8-2(*) /64 Fig. 21 X ST(**)13-2(*) RST(**)13-2(*) /64 Fig. 21 X (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Voltage rating of all units is 600 Volts AC RMS. Ground wire connector supplied (#14-#2 CU/AL). A universal test switch mounting plate is supplied without a test switch. 2-PIECE COVER Ring style units are supplied with snap-type sealing rings. UL (Underwriters Laboratories) label available. (**) Units are supplied with either a low test switch bridge or standard test switch bridge. Please use the appropriate prefix, L or S, to designate. (Example: for low test switch bridge, ST(L)13-2(*), for standard test switch bridge, ST(S)13-2(*). Contact factory or your local manufacturer s agent to specify test switches, diagrams, and other special features or prewired options. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 K 1 1/4 L 1 1/2 M 15

23 METER SOCKETS 400 AMPERE RING CURRENT TRANSFORMER 5 TERMINAL TSB4050U TSB4059U CATALOG NUMBER WITH STUDS WITH DUAL #6-350 CONN. NON- CIRCUIT CLOSING AUTO CIRCUIT CLOSING CABINET DIMENSIONS HEIGHT WIDTH DEPTH KNOCKOUT CONFIGURATION TSB4050(*) X 31 1/2 16 3/4 6 63/64 Fig. 23 TSBN4050(*) X 31 1/2 16 3/4 6 63/64 Fig. 23 TSB4059(*) X 31 1/2 16 3/4 6 63/64 Fig. 23 TSBN4059(*) X 31 1/2 16 3/4 6 63/64 Fig. 23 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Voltage rating of all units is 600 Volts AC RMS. Current rating of all units is 400 ampere maximum. Units supplied with 200/200.5 current transformer. Ground wire connector supplied (#14-1/0 CU/AL). Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB(LG) HCP(LG) 3 (LG) CATALOG SUFFIX A T U Q 3 1/2 (LG) R 4 (LG) S 16

24 TRANSOCKET FAMILY 17

25 TRANSOCKETS AMPERES 1 & 3 PHASE PRE-WIRED TSSC1332U TSDF1334U Transockets are supplied in galvanized steel or aluminum construction. Please contact factory or local manufacturer s representative. Transockets are supplied for overhead, underground, or overhead/underground combinations. Please specify when asking for quote. For Pre-Wired Units, contact factory or local manufacturer s representative about wiring diagram and color code. 18

26 GENERAL ORDERING INFORMATION FOR DESIGNING A TRANSOCKET 1PH 3PH METER FORM NUMBER OF TERMINALS AMPERAGE VOLTAGE RING FRONT RINGLESS FRONT GALVANIZED STEEL CONSTRUCTION ALUMINUM CONSTRUCTION OVERHEAD UNDERGROUND OVERHEAD/UNDERGROUND CURRENT TRANSFORMERS (IF APPLICABLE) BAR CT s WINDOW CT s SIZE CONNECTORS (BAR TYPE CT s) RATIO OF CT s VOLTAGE TRANSFORMERS (IF APPLICABLE) VT RATIO IF UNIT IS TO BE FACTORY WIRED PLEASE INCLUDE WIRING DIAGRAM AND COLOR CODE 19

27 METER SOCKETS AND ENCLOSURES KNOCKOUT CONFIGURATION CHARTS D D D C E C =5/16 DIA KO =1/2 KO A =3/4 KO B =1 KO C =1-1/4 KO D =1-1/2 KO E =2 KO F =2-1/2 KO F F F G =3 KO F F F H =3-1/2 KO F F F J =4 KO F F F G G G F FIG. 1 FIG. 2 FIG. 3 FIG. 4 F F A F A A A G F F G F G G G F G A G G G G G G FIG. 5 FIG. 6 FIG. 7 FIG. 8 G G G H H H H H H J J G G G H H H H H H J J J FIG. 9 FIG. 10 FIG. 11 FIG. 12 TYPICAL ALL METER POSITIONS TYPICAL ALL METER POSITIONS F F F F F F F F F F F G F F FIG. 13 FIG

28 METER SOCKETS & ENCLOSURES KNOCKOUT CONFIGURATION CHARTS A B C D E F G H J =5/16 DIA KO =1/2 KO =3/4 KO =1 KO =1-1/4 KO =1-1/2 KO =2 KO =2-1/2 KO =3 KO =3-1/2 KO =4 KO FIG. 15 FIG. 16 FIG. 17 FIG. 18 FIG. 19 FIG. 20 FIG. 21 FIG. 22 FIG. 23 FIG. 24 FIG. 25 FIG. 26 FIG

29 TEST SWITCH FAMILY UL R SPECIFICATIONS Underwriters Laboratories listed are recognized components UL label can be supplied if required. Test Switches are built to ANSI C12.9 standards. Test Switch ratings are 30 ampere at 600 VAC 22

30 TEST SWITCH DIVISION 23

31 TEST SWITCH DIVISION OPTIONS AVAILABLE 24

32 TEST SWITCH DIVISION MOUNTING DIMENSIONS MOUNTING DIMENSIONS (Molded Bases) DIMENSIONS (Inches) # Pole Sw. A B C D 4 Pole 4-5/8 3-1/2 3-5/8 2-1/2 7 Pole 7-1/2 3-1/2 6-1/2 2-1/2 10 Pole 9-1/2 3-1/2 8-1/2 2-1/2 12 Pole 11-1/2 3-1/2 10-1/2 2-1/2 Note: Consult Factory For Other Base Dimensions NOTES 25

33 CATALOG NUMBERS FOR TYPICAL TEST SWITCHES FRONT CONNECTED 26

34 CATALOG NUMBERS FOR TYPICAL TEST SWITCHES FRONT CONNECTED 27

35 ACCESSORIES AND SAF-T-PLUG 3614B-00 ACCESSORIES (Standard Covers) Base Size Front Connected Switch Back Connected Switch 4-5/8 7-1/2 9-1/2 11-1/2 Black Fiberglass 7941 FC 7942 FC 7943 FC 7944 FC Clear Lexan 7941 FC-CL N/A 7943 FC-CL N/A Black Fiberglass 7941 BC 7942 BC 7943 BC 7944 BC Clear Lexan N/A N/A 7943 BC-CL N/A 28

36 FOR SPECIAL ORDER TEST SWITCHES 29

37 CURRENT TRANSFORMER ENCLOSURE FAMILY 30

38 CURRENT TRANSFORMER ENCLOSURES RD SERIES 1) All hardware is stainless steel. 2) Hinges and pins are stainless steel. 3) Supplied with 3-point latch with stainless steel pad lockable handle. 4) Supplied with #14-2/0 ground connector. CAT# PLYWOOD CAT# RAILS H W D MATL PLYWOOD SIZE GALVANIZED STEEL RDW RDR GA 18H X 22W RDW RDR GA 18H X 28W RDW RDR GA 24H X 22W RDW RDR GA 24H X 28W RDW RDR GA 24H X 34W RDW RDR GA 30H X 28W RDW RDR GA 30H X 34W RDW RDR GA 36H X 40W ALUMINUM A RDW A RDR H X 22W A RDW A RDR H X 28W A RDW A RDR H X 22W A RDW A RDR H X 28W A RDW A RDR H X 34W A RDW A RDR H X 28W A RDW A RDR H X 34W A RDW A RDR H X 40W # OF HORZ RAILS

39 CURRENT TRANSFORMER ENCLOSURES SF SERIES 1) All hardware is stainless steel. 2) Handles are aluminum. 3) Supplied with (2) stainless steel pad lockable latches and latch tabs. 4) Supplied with #14-2/0 ground connector. CAT# PLYWOOD CAT# RAILS H W D MATL PLYWOOD SIZE GALVANIZED STEEL SFW SFR GA 18H X 22W SFW SFR GA 18H X 28W SFW SFR GA 24H X 22W SFW SFR GA 24H X 28W SFW SFR GA 24H X 34W SFW SFR GA 30H X 28W SFW SFR GA 30H X 34W SFW SFR GA 36H X 40W SFW SFR GA 36H X 46W SFW SFR GA 42H X 40W SFW SFR GA 42H X 46W ALUMINUM A SFW A SFR H X 22W A SFW A SFR H X 28W A SFW A SFR H X 22W A SFW A SFR H X 28W A SFW A SFR H X 34W A SFW A SFR H X 28W A SFW A SFR H X 34W A SFW A SFR H X 40W A SFW A SFR H X 46W A SFW A SFR H X 40W A SFW A SFR H X 46W # OF HORZ RAILS

40 CURRENT TRANSFORMER ENCLOSURES DD SERIES 1) All hardware is stainless steel. 2) Hinges and pins are stainless steel. 3) Supplied with 3-point latch with stainless steel pad lockable handle. 4) Supplied with #14-2/0 ground connector. CAT# PLYWOOD CAT# RAILS H W D MATL PLYWOOD SIZE GALVANIZED STEEL DDW DDR GA 24H X 34W DDW DDR GA 30H X 34W DDW DDR GA 36H X 40W DDW DDR GA 36H X 46W DDW DDR GA 42H X 40W DDW DDR GA 42H X 46W ALUMINUM A DDW A DDR H X 34W A DDW A DDR H X 34W A DDW A DDR H X 40W A DDW A DDR H X 46W A DDW A DDR H X 40W A DDW A DDR H X 46W # OF HORZ RAILS POLE MOUNTING BRACKETS (SEE PAGE 34 FOR DETAILS) 33

41 CURRENT TRANSFORMER ENCLOSURE ACCESSORIES PLYWOOD BACK BOARD Material 3/4 thick grade BB plywood Height = enclosure height - 6 Width = enclosure width - 2 RAIL ASSEMBLY 3 X 7/16 oblong typical Height = enclosure height - 6 Width = enclosure width - 2 POLE MOUNTING BRACKETS 1 X 13/32 oblong (3) 3/4 ARP Steel Fits units wide ARP Aluminum Fits units wide ARP Steel Fits units wide 34

42 SOCKET BREAKER ENCLOSURE FAMILY 35

43 SOCKET BREAKER COMBINATIONS 100 AMPERE RING & RINGLESS SINGLE PHASE PD SERIES READY SEE PAGE 59 DH122NOB P140WOB H122NOB CATALOG NUMBER DIMENSIONS KO FIG. # RINGLESS RING HEIGHT WIDTH DEPTH H122N0(*) RH122N0(*) 23 3/ /2 Fig. 1 2 X DH122N0(*) DRH122N0(*) 23 3/ /2 Fig. 1 X 2 X DH122W0(*) DRH122W0(*) 23 3/ /8 Fig. 11 X 2 X P120N0(*) RP120N0(*) 23 3/ /2 Fig. 1 2 X DP122N0(*) DRP122N0(*) 23 3/ /2 Fig. 1 X 2 X DP122W0(*) DRP122W0(*) 23 3/ /8 Fig. 11 X 2 X P140W0(*) RP140W0(*) /8 Fig X (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. WITH DIST. CTR. # OF POLES PROVISIONS FOR PLUG-IN BREAKER (2) POLE HEINEMANN BREAKER INSTALLED WITH 100 AMP (2) POLE PLUG-IN BREAKER INSTALLED Line connectors are #6-2/0 CU/AL. Units supplied with distribution center have (3) #14-1/0 CU/AL connectors on the load side of the breaker. Ring units are supplied less sealing ring. To order a U.L. listed unit add the U prefix (example: UH122N0B). Plug-in breaker units will accept Westinghouse type QUICKLAG P, ITE type QP, Bryant type BR, or Square-D type Homeline breakers. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 1/4 L 1 1/2 M 2 N 2 1/2 P 36

44 SOCKET BREAKER COMBINATIONS 200 AMPERE RING & RINGLESS SINGLE PHASE S B PD SERIES READY SEE PAGE 59 DC222WIB C262WIN CATALOG NUMBER DIMENSIONS KO WITH PROVISIONS FOR ADDL. RINGLESS RING HEIGHT WIDTH DEPTH FIG. # DIST. CTR. PLUG IN BREAKERS C222N1(*) RC222N1(*) /8 Fig. #2 C222W1(*) RC222W1(*) /8 Fig. #3 DC222W1(*) RDC222W1(*) /8 Fig. #3 X C242W1(*) RC242W1(*) 29 3/ /64 Fig. #3 X C262W1(*) RC262W1(*) 29 3/ /8 Fig. #3 X (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. Line, load, and neutral connectors are #6-250 CU/AL. Units supplied with distribution center have (2) #6-250 (1) #12-2/0CU/AL connectors on the load side of the breaker. Ring units are supplied less sealing ring. To order a U.L. listed unit add the U prefix (example: UC222N0B). Plug-in breaker units will accept Westinghouse type QUICKLAG P, ITE type QP, Bryant type BR, or Square-D type Homeline breakers. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 1/4 L 1 1/2 M 2 N 2 1/2 P 37

45 SOCKET BREAKER COMBINATIONS 320 AMPERE RINGLESS 4 TERMINAL LEVER BYPASS W/JAW RELEASE PD SERIES READY CAT # UHC344N3T HC364N4T CATALOG # OF CABINET DIMENSIONS KNOCKOUT WIRE SIZE CU-AL NUMBER JAWS HEIGHT WIDTH DEPTH CONFIGURATION LINE LOAD UHC344N3T / /2 4 5/16 Fig. 10 (2)# /0-250 UHC344N5T / /2 4 5/16 Fig. 10 (2)# /0-250 HC364N4T / /2 4 4/16 Fig. 10 (2)# /0-250 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. PD Series Pedestal Select optional accessories from Meter Socket Options, page 82, and add the appropriate prefixes to the catalog number. Add prefix T for ground wire connector (#14-#1/0 CU/AL). UL (Underwriters Laboratories) label available on most units. Contact factory or your local manufacturer s agent for special units or nonstandard options. HUB SELECTION CHART HUB OR TOP CONFIGURATION FOR HUB (LG) HCP (LG) CATALOG SUFFIX T U 3 (LG) Q 3 1/2 (LG) R 4 (LG) S 38

46 GANG SOCKET BREAKER COMBINATIONS 100 AND 200 AMPERE RINGLESS ONLY SINGLE PHASE HUB SELECTION CHART HUB OR TOP CONFIGURATION Small SOLID FOR HUB(SM) HCP(SM) CATALOG SUFFIX A B C 1 1/4 (SM) L 1 1/2 (SM) M 2 (SM) N 2 1/2 (SM) P Large FOR HUB(LG) T HCP(LG) U 2 1/2 (LG) V 3 (LG) Q 3 1/2 (LG) R 4 (LG) S SBG1012B 100 AMPERE CATALOG # OF CABINET DIMENSIONS KNOCKOUT LINE SIDE NUMBER POSITIONS HEIGHT WIDTH DEPTH CONFIGURATION WIRE SIZE SBG1012(*) /8 24 5/16 4 1/2 Fig. 4 #6-250 SBG1013(*) / /32 4 1/2 Fig. 4 #6-250 SBG1014(*) /8 40 5/8 4 1/2 Fig. 4 #6-250 SBG1015(*) / /32 4 1/2 Fig. 4 #6-250 SBG1016(*) / /16 4 1/2 Fig. 4 # AMPERE CATALOG # OF CABINET DIMENSIONS KNOCKOUT LINE SIDE NUMBER POSITIONS HEIGHT WIDTH DEPTH CONFIGURATION WIRE SIZE SBG2022(*) /8 24 5/16 5 3/8 Fig. 5 #6-250 SBG2023(*) / /32 5 3/8 Fig. 5 #6-350 SBG2024(*) /8 40 5/8 5 3/8 Fig. 5 1/0-500 SBG2025(*)(*) / /8 Fig /0-500 SBG2026(*)(*) /8 63 1/8 5 3/8 Fig /0-500 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. + Has provisions for (2) 1/0-350 as well. 100 ampere units are supplied without breakers. 100 ampere units will accept Westinghouse type QUICKLAG P, ITE type QP, Bryant type BR, or Square-D type Homeline breakers. 200 ampere units are supplied with a 200 amp Cutler Hammer CCH breaker. 39

47 SOCKET BREAKER TRANSFER SWITCH W/METERING PROVISION 100 AND 200 AMPERE RINGLESS ONLY SINGLE PHASE SIDE VIEW** PD SERIES READY SEE PAGE 59 SB204DT100B SB114DT100B SB204DT100B CATALOG NUMBER MAIN AUXILIARY SB114DT50* SB114DT100* SB204DT50* SB204DT100* 100 Amp Main 100 Amp Main 200 Amp Main 200 Amp Main 50 Amp Auxiliary 100 Amp Auxiliary 50 Amp Auxiliary 100 Amp Auxiliary *Select Hub needed from selection chart and add suffix to catalog number. Add U prefix for UL label. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID TOP (SM) HUB OPENING COVER PLATE (SM) 1 1/4 (SM) 1 1/2 (SM) 2 (SM) 2 1/2 (SM) CATALOG SUFFIX A B C L M N P Unit Information Socket Type: Terminal Self-Contained Line Side: #8-2/0 CU-AL Wire Range Auxiliary: #14-1/0 CU 100 Amp Main Load Side: (1) #6-250 kcmil CU-AL & (3) #14-1/0 CU-AL Size 30 3/8 H x 12 W x4 3/8 D Weight 40 Pounds Line Side: #6-250 kcmil CU-AL Wire Range Auxiliary: #14-1/0 CU 200 Amp Main Load Size: (3) #6-250 kcmil CU-AL Size 34 1/4 H x 13 W x 4 3/8 D Weight 50 Pounds For male 50 amp locking-type receptacle installed & prewired to auxiliary connectors, add suffix R to catalog number. Example Catalog (USB114DTR50B). For field installable 50 ampere twist lock receptacle order catalog number ARP Units with receptacles limited to 50A (12KW) aux, input. Add 2 lbs. to weight for receptacle. UNITS HAVE MULTI-RING KNOCK OUTS WITH A MAXIMUM OF 2 1/2 ON BOTTOM BACK SIDE. **Placement for receptacle shown. Unit is shipped with cover plate over the provision as shown. 40

48 SOCKET BREAKER COMBINATIONS KNOCKOUT COMBINATION CHARTS E G D D F G F F E E E FIG. 10 FIG

49 METER SOCKET TRANSFER SWITCH ENCLOSURE FAMILY 42

50 METER SOCKET TRANSFER SWITCH 100 THRU 600 AMPERE SINGLE PHASE 240 V.A.C SSV110DT-B HUB SELECTION CHART HUB OR TOP CONFIGURATION Small SOLID FOR HUB(SM) HCP(SM) CATALOG SUFFIX A B C 1 1/4 (SM) L 1 1/2 (SM) M 2 (SM) N 2 1/2 (SM) P Large FOR HUB(LG) T HCP(LG) U 2 1/2 (LG) V 3 (LG) Q 3 1/2 (LG) R 4 (LG) S SSV410DT-T CATALOG NUMBER SSV110DT-(*) Ringless SSV210DT-(*) Ringless SOCKET TYPE 4 Term. Self-Cont. 4 Term. Self-Cont. METER FORM CURRENT TRANS. RATIO MAIN AUXIL. RATING RATING WIRE SIZE CU-AL LINE LOAD DIMENSIONS H. W. D. SHIP. WGT. K.O. FIG. # 2S N/A 100 amp 100 amp 2/0 (4) 1/ /4 4 5 Fig. 1 2S N/A 200 amp 200 amp 350 MCM (4) 250 MCM 40 1 / / /2 7 2 Fig. 2 SSV211DT-(*) Ringless SSV310DT-(*) Ringless SSV410DT-(*) Ring +SSV610DT-(*) Ring 4 Term. Self-Cont. Lever By-Pass 4 Term. Self-Cont. Lever By-Pass 5 Term. Auto. Circuit Closing 5 Term. Auto. Circuit Closing 2S N/A 200 amp 200 amp 350 MCM (4) 250 MCM 40 1 / / /2 7 5 Fig. 2 2S N/A 320 amp 320 amp (2) 350 MCM (4) 350 MCM 55 1 / / / Fig. 3 3S 200/200:5 400 amp 400 amp (2) 350 MCM (4) 350 MCM 46 1 / / / Fig. 3 3S 300/300:5 600 amp 600 amp (2) 500 MCM (1) 500 MCM (3) 350 MCM /4 205 Fig. 4 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog + Does not have provisions for a twist lock receptacle. Switches are double pole/double throw with center off position. For male 50 ampere twist lock receptacle installed and prewired to auxiliary connectors, add suffix R to catalog number (example: SV110DTR-B). Single phase units with receptacles are limited to 12 KW (50 ampere) auxiliary input. For field installable 50 ampere twist lock receptacle order catalog number ARP

51 METER SOCKET TRANSFER SWITCH 100 THRU 600 AMPERE THREE PHASE 240 V.A.C. HUB SELECTION CHART HUB OR TOP CONFIGURATION Small SOLID FOR HUB(SM) HCP(SM) CATALOG SUFFIX A B C 1 1/4 (SM) L 1 1/2 (SM) M 2 (SM) N 2 1/2 (SM) P Large FOR HUB(LG) T HCP(LG) U 2 1/2 (LG) V 3 (LG) Q 3 1/2 (LG) R 4 (LG) S SSV423DT-T CATALOG NUMBER SOCKET TYPE METER FORM CURRENT TRANS. RATIO MAIN AUXIL. RATING RATING WIRE SIZE CU-AL LINE LOAD DIMENSIONS H. W. D. SHIP. WGT. K.O. FIG. # SSV113DT-(*) 7 Term. 15S N/A 100 amp 100 amp 1/0 (4) 1/ / Fig. 5 Self-Cont. 7 Term. SSV213DT-(*) Self-Cont. 15S N/A 200 amp 200 amp 350 MCM (4) 250 MCM /2 115 Fig. 5 Lever By-Pass SSV233DT-(*) 13 Term. 8S (3) 200 amp 200 amp 250 MCM (4) 250 MCM /2 135 Fig. 5 Lever By-Pass 200:5 +SSV423DT-(*) 13 Term. 8S (3) 400 amp 400 amp (2) 350 MCM (4) 350 MCM /4 185 Fig. 6 Lever By-Pass 400:5 +SSV623DT-(*) 13 Term. 8S (3) 600 amp 600 amp (2) 500 MCM (1) 500 MCM /4 290 Fig. 7 Lever By-Pass 400:5 (3) 350 MCM (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. + Does not have provisions for a twist lock receptacle. Switches are triple pole/double throw with center off position. For male 30 ampere twist lock receptacle installed and prewired to auxiliary connectors add the suffix R to catalog number (example: SSV213DTR-B). Three phase units with receptacles are limited to 12 KW (50 ampere) auxiliary input. 44

52 METER SOCKET TRANSFER SWITCH 100 THRU 600 AMPERE SINGLE PHASE 240 V.A.C. SSV211DTSS-A SSV410DTSS-A CATALOG NUMBER SSV210DTSS-A SOCKET TYPE 4 Term. Self-Cont. METER FORM CURRENT TRANS. RATIO MAIN AUXIL. RATING RATING WIRE SIZE CU-AL LINE LOAD DIMENSIONS H. W. D. SHIP. WGT. K.O. FIG. # 2S N/A 200 amp 200 amp 350 MCM (4) 250 MCM /4 9 5 Fig. 8 SSV211DTSS-A SSV212DTSS-A SSV310DTSS-A SSV410DTSS-A +SSV610DTSS-A 4 Term. Self-Cont. Lever By-Pass 5 Term. Auto. Circuit Closing 4 Term. Self-Cont. Lever By-Pass 5 Term. Auto. Circuit Closing 5 Term. Auto. Circuit Closing 2S N/A 200 amp 200 amp 350 MCM (4) 250 MCM /4 102 Fig. 8 3S 100/100:5 200 amp 200 amp 350 MCM (4) 250 MCM /4 108 Fig. 8 2S N/A 320 amp 320 amp (2) 350 MCM (4) 350 MCM /4 170 Fig. 9 3S 200/200:5 400 amp 400 amp (2) 350 MCM (4) 350 MCM /4 185 Fig. 9 3S 300/300:5 600 amp 600 amp (2) 500 MCM (1) 500 MCM (3) 350 MCM (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. + Does not have provisions for a twist lock receptacle. Switches are double pole/double throw with center off position. For male 50 ampere twist lock receptacle installed and prewired to auxiliary connectors, add suffix R to catalog number (example: SSV210DTRSS-A). Single phase units with receptacles are limited to 12 KW (50 ampere) auxiliary input. For field installable 50 ampere twist lock receptacle order catalog number ARP / /4 245 Fig. 10 Units shown have solid tops. 45

53 METER SOCKET TRANSFER SWITCH 200 THRU 600 AMPERE THREE PHASE 240 V.A.C. SSV233DTSS-A CATALOG NUMBER SSV213DTSS-A SOCKET TYPE 7 Term. Self-Cont. Lever By-Pass METER FORM 12S CURRENT TRANS. RATIO N/A MAIN AUXIL. RATING RATING 200 amp 200 amp WIRE SIZE CU-AL DIMENSIONS SHIP. LINE LOAD H. W. D. WGT. 350 MCM (4) 250 MCM 35 1 / /4 8 1 /2 124 K.O. FIG. # Fig. 11 SSV233DTSS-A +SSV423DTSS-A 13 Term. Lever By-Pass 13 Term. Lever By-Pass 8S 8S (3) 200:5 (3) 400:5 200 amp 400 amp 200 amp 350 MCM (4) 250 MCM 400 amp (2) 350 MCM (4) 350 MCM 35 1 / /4 8 1 / / / / Fig. 11 Fig. 12 +SSV623DTSS-A 13 Term. Lever By-Pass 8S (3) 400:5 600 amp 600 amp (2) 500 MCM (1) 500 MCM (3) 350 MCM /4 302 Fig Does not have provisions for a twist lock receptacle. Switches are triple pole/double throw with center off position. For male 30 ampere twist lock receptacle installed and prewired to auxiliary connectors, add suffix R to catalog number (example: SSV213DTRSS-A). Three phase units with receptacles are limited to 12 KW (50 ampere) auxiliary input. Units shown have solid tops. 46

54 TRANSFER SWITCH ENCLOSURES 100 THRU 600 AMPERE SINGLE & THREE PHASE 240 V.A.C THREE PHASE CATALOG NUMBER HUB OPENING SV213DT-T SINGLE PHASE CATALOG HUB MAIN AUXILIARY WIRE SIZE CU-AL AUXILIARY DIMENSIONS SHIPPING KO NUMBER OPENING RATING RATING LINE LOAD CONNECT. H. W. D. WEIGHT FIG. # SV110DT-(*) SMALL /0 (4) 1/0 1/ /4 45 Fig. #4 SV210DT-(*) SMALL (4) /2 60 Fig. #5 SV410DT-(*) LARGE (2) 350 (4) 350 (2) /4 110 Fig. #6 +SV610DT-(*) LARGE (2) 500 (1) 500 (2) / /4 170 Fig. #7 (3) 350 MAIN AUXILIARY RATING SV113DT-(*) SMALL /0 (4) 1/0 1/ /2 75 Fig. #8 SV213DT-(*) LARGE (4) / /2 8 5 Fig. #8 +SV413DT-(*) LARGE (2) 350 (4) 350 (2) /4 125 Fig. #9 +SV613DT-(*)(*) LARGE (2) 500 (1) 500 (2) / /2 15 1/4 240 Fig. #10 (3) 350 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. SINGLE PHASE Switches are double pole/double throw with a center off position. For male 50 ampere twist lock receptacle installed and prewired to auxiliary connectors, add suffix R to catalog number (example: SV110DTR-B). Single phase units with receptacles are limited to 12 KW (50 ampere) auxiliary input. For field installable 50 ampere twist lock receptacle order catalog number ARP THREE PHASE Switches are triple pole/double throw with a center off position. Contact the factory for any information on factory installed twist lock receptacles for three phase units. + Does not have provisions for a twist lock receptacle. WIRE SIZE CU-AL AUXILIARY DIMENSIONS SHIPPING RATING LINE LOAD CONNECT. H. W. D. WEIGHT 47 HUB SELECTION CHART HUB OR TOP CONFIGURATION Small SOLID FOR HUB(SM) HCP(SM) CATALOG SUFFIX A B C 1 1/4 (SM) L 1 1/2 (SM) M 2 (SM) N 2 1/2 (SM) P Large FOR HUB(LG) T HCP(LG) U 2 1/2 (LG) V 3 (LG) Q 3 1/2 (LG) R 4 (LG) S KO FIG. #

55 METER SOCKET PAD MOUNT TRANSFER SWITCH 200 THRU 600 AMPERE SINGLE PHASE 240 V.A.C. PCV211DT PCV410DT CATALOG NUMBER SOCKET TYPE METER FORM CURRENT TRANS. RATIO MAIN AUXIL. RATING RATING WIRE SIZE CU-AL LINE LOAD DIMENSIONS H. W. D. SHIP. WGT. PCV210DT 4 Term. 2S N/A 200 amp 200 amp 350 MCM (4) 250 MCM /4 102 Self-Cont. 4 Term. PCV211DT Self-Cont. 2S N/A 200 amp 200 amp 350 MCM (4) 250 MCM /4 110 Lever By-Pass 5 Term. PCV212DT Auto. Circuit 3S 100/100:5 200 amp 200 amp 350 MCM (4) 250 MCM /4 112 Closing 4 Term. +PCV310DT Self-Cont. 2S N/A 320 amp 320 amp (2) 350 MCM (4) 350 MCM 46 1 / /4 150 Lever By-Pass 5 Term. +PCV410DT Auto. Circuit 3S 200/200:5 400 amp 400 amp (2) 350 MCM (4) 350 MCM 46 1 / /4 162 Closing 5 Term. +PCV610DT Auto. Circuit 3S 300/300:5 600 amp 600 amp (2) 500 MCM (1) 500 MCM 58 9 / / /4 285 Closing (3) 350 MCM + Does not have provisions for a twist lock receptacle. Switches are double pole/double throw with center off position. For male 50 ampere twist lock receptacle installed and prewired to auxiliary connectors, add suffix R to catalog number (example: PCV210DTR). Single phase units with receptacles are limited to 12 KW (50 ampere) auxiliary input. For field installable 50 ampere twist lock receptacle order catalog number ARP00176 See page 50 for burial sleeves. 48

56 METER SOCKET PAD MOUNT TRANSFER SWITCH 200 THRU 600 AMPERE THREE PHASE 240 V.A.C. PCV233DT PCV423DT CATALOG NUMBER SOCKET TYPE 7 Term. PCV223DT Self-Cont. 15S N/A 200 amp 200 amp 350 MCM (4) 250 MCM /4 8 1 /2 125 Lever By-Pass PCV233DT 13 Term. 8S (3) 200 amp 200 amp 350 MCM (4) 250 MCM /4 8 1 /2 137 Lever By-Pass 200:5 +PCV423DT 13 Term. 8S (3) 400 amp 400 amp (2) 350 MCM (4) 350 MCM 461/2 401/4 113/4 227 Lever By-Pass 400:5 +PCV623DT 13 Term. 8S (3) 600 amp 600 amp (2) 500 MCM (1) 500 MCM /4 312 Lever By-Pass 400:5 (3) 350 MCM + Does not have provisions for a twist lock receptacle. Switches are triple pole/double throw with center off position. For male 30 ampere twist lock receptacle installed and prewired to auxiliary connectors, add suffix R to catalog number (example: PCV223DTR). Three phase units with receptacles are limited to 12 KW (50 ampere) auxiliary input. See page 50 for burial sleeves. METER FORM CURRENT TRANS. RATIO MAIN AUXIL. RATING RATING WIRE SIZE CU-AL LINE LOAD DIMENSIONS H. W. D. SHIP. WGT. 49

57 METER SOCKET PAD MOUNT TRANSFER SWITCH BURIAL MOUNTING SLEEVES ORDERING INFORMATION CATALOG BD W D FITS SERIES SHIPPING NUMBER WEIGHT /4 200 Amp Single Phase PCV s /4 8 1/2 200 Amp Three Phase PCV s /4 320 Amp-400 Amp Single Phase PCV s /4 11 3/4 400 Amp Three Phase PCV s /8 15 1/4 600 Amp Single Phase PCV s /4 600 Amp Three Phase PCV s 82 Burial Sleeves are fabricated from 14 gauge galvanized steel and have an oven cured powder polyester finish. 50

58 BREAKER ENCLOSURE FAMILY 51

59 BREAKER ENCLOSURES 100 AMPERE SINGLE PHASE B B PROVISIONS WITH 100 AMP BREAKER TYPE CATALOG DIMENSIONS KO FOR 2-POLE BKR. HEINEMANN G.E NUMBER HEIGHT WIDTH DEPTH FIG. # BREAKER INSTALLED CE-1 THQC (*) 16 1/ /2 Fig. 1 X X (*) 16 1/ /2 Fig. 1 X X (*) 16 1/ /2 Fig. 1 X X (*) 16 1/ /2 Fig. 1 X X (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. To order a U.L. listed unit add the U prefix in front of the catalog number (example: U B). HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 1/4 L 1 1/2 M 2 N 2 1/2 P 52

60 BREAKER ENCLOSURES 125 THRU 225 AMPERE SINGLE PHASE 2020B 2022B CATALOG DIMENSIONS KO PROVISIONS FOR WITH BREAKER BREAKER NUMBER HEIGHT WIDTH DEPTH FIG. # BREAKER INSTALLED AMPACITY 2020(*) 23 3/ /64 Fig. 2 X N/A 1252(*) 19 1/ /8 Fig. 2 X (*) 19 1/ /8 Fig. 2 X (*) 19 1/ /8 Fig. 2 X (*) 23 3/ /64 Fig. 2 X (*) 23 3/ /64 Fig. 2 X 225 (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 1/4 L 1 1/2 M 2 N 2 1/2 P 53

61 BREAKER ENCLOSURES 200 AMPERE SINGLE PHASE CB242WOB CATALOG NUMBER HEIGHT DIMENSIONS WIDTH DEPTH KO FIG. # UNIT RATING MAIN BKR. RATING # OF PLUG-IN POLES AVAILABLE CB542W0(*) 23 1/ /64 Fig CB562W0(*) 23 1/ /64 Fig CB242W0(*) 24 3/ /8 Fig CB262W0(*) 24 3/ /8 Fig (*) Select desired bolt-on hub or top configuration from HUB SELECTION CHART and add the appropriate suffix to the catalog number. To order a U.L. listed unit add the U prefix (example: UCB542W0B). Plug-in breaker units will accept Westinghouse type QUICKLAG P, ITE type QP, Bryant type BR, or Square-D type Homeline breakers. HUB SELECTION CHART HUB OR TOP CONFIGURATION SOLID FOR HUB HCP CATALOG SUFFIX A B C 1 1/4 L 1 1/2 M 2 N 2 1/2 P 54

62 BREAKER TRANSFER SWITCH ENCLOSURE W/O METERING PROVISION 100 AND 200 AMPERE SINGLE PHASE SIDE VIEW** B114DT100B B204DT100B B204DT100B CATALOG NUMBER MAIN AUXILIARY B114DT50* B114DT100* B204DT50* B204DT100* 100 Amp Main 100 Amp Main 200 Amp Main 200 Amp Main 50 Amp Auxiliary 100 Amp Auxiliary 50 Amp Auxiliary 100 Amp Auxiliary *Select Hub needed from selection chart and add suffix to catalog number. Add U prefix for UL label. HUB SELECTION CHART HUB OR TOP CONFIGURATION TOP FOR HUB HCP(SM) 1 1/4 (SM) 1 1/2 (SM) 2 (SM) 2 1/2 (SM) CATALOG SUFFIX A B C L M N P Unit Information Socket Type: Terminal Self-Contained Line Side: #8-2/0 CU-AL Wire Range Auxiliary: #14-1/0 CU 100 Amp Main Load Side: (1) #6-250 kcmil CU-AL or (3) #14-1/0 CU-AL Size 23 3/8 H x 12 W x 4 3/8 D Weight 30 Pounds Line Side: #6-250 kcmil CU-AL Wire Range Auxiliary: #14-1/0 CU 200 Amp Main Load Size: (3) #6-250 kcmil CU-AL Size 26 1/2 H x 13 W x 4 3/8 D Weight 40 Pounds For male 50 amp locking-type receptacle installed & prewired to auxiliary connectors, add suffix R to catalog number. Example Catalog (USB114DTR50B). For field installable 50 ampere twist lock receptacle order catalog number ARP Units with receptacles limited to 50A (12KW) auxiliary input. Add 2 lbs. to weight for receptacle. UNITS HAVE MULTI-RING KNOCK OUTS WITH A MAXIMUM OF 2 1/2 ON BOTTOM BACK SIDE. **Placement for receptacle shown. Unit is shipped with cover plate over the provision as shown. 55

63 BREAKER OR TRANSFER SWITCH ENCLOSURES KNOCKOUT CONFIGURATION CHARTS 56

64 METER PEDESTAL FAMILY 57

65 METER PEDESTALS 100, 200, & 320 AMPERE SINGLE PHASE 1, 2, & 3 POSITION PD 79-1 PD 79-2 PD 79-3 PEDESTAL NUMBERS CATALOG NUMBER # OF POSITIONS HEIGHT DIMENSIONS WIDTH DEPTH PD PD /4 PD /2 5 3/4 PD PD /4 PD /2 5 3/ MAX AMP All pedestals have hemmed edges at bottom to protect conductor insulation. All pedestals have removable bottom covers to allow lay-in wiring. All line terminals are 350 MCM CU-AL, all subfeed terminals are 250 MCM CU-AL. Contact the factory or your nearest manufacturer s agent to order preassembled units or any other special features. Stabilizer foot shipped inside unit. The following units have been designed for no-drill mounting to the PD series pedestals TYPE OF RATINGS CATALOG UNIT NUMBERS METER 100 AMP PDMS100 SOCKETS 200 AMP PDMS200 SOCKET BREAKERS 100 AMP see page AMP see page AMP see page 38 58

66 METER PEDESTALS 200 AMPERE RINGLESS STYLE DIRECT BURIED NOTE: 200A Plug in breaker installed P711S262W1 P722S262W1 CATALOG NUMBER # OF POSITIONS HEIGHT DIMENSIONS WIDTH DEPTH P711S262W P722S262W /4 P711S260W P722S260W /4 DIMENSIONS LINE LOAD (2)-350 #6-250 (2)-350 #6-250 (2)-350 #6-250 (2)-350 #6-250 PLUG IN BREAKER INSTALLED x x Unit is supplied with 200A, 2 pole, plug in breaker and has provisions for TWO (2) additional 2 pole breakers in a parallel circuit which will accept Westinghouse Quicklag P, ITE-QP, G.E. Q-Line, Bryant-BR, & Square D-Homeline plug in breakers. Stabilizer foot shipped inside unit. 59

67 METER PEDESTALS 200 AMPERE SINGLE & THREE PHASE LEVER BY-PASS DIMENSIONS APPLICATION Use these lever by-pass pedestals to direct meter single phase and three phase services. They are designed to mount on individual pads or burial sleeves as well as on enlarged transformer pads with the transformer. MPC units use CQ style plug-in lever by-pass sockets and MPH units use HQ style locking jaw lever by-pass sockets. The MP200 series units use HQ style sockets, are in a wider cabinet, and are prebussed for direct wiring. CATALOG NUMBER AMPACITY MAIN BY-PASS # OF TERMINALS PHASE APPROXIMATE SHIP. WEIGHT MPC SINGLE PHASE 3-WIRE 50 MPC SINGLE PHASE 3-WIRE or NETWORK 3-WIRE 50 MPC THREE PHASE 3-WIRE 50 MPH SINGLE PHASE 3-WIRE 50 MPH SINGLE PHASE 3-WIRE, NETWORK 3-WIRE 50 or THREE PHASE 3-WIRE MPH THREE PHASE 4-WIRE 50 MP THREE PHASE 3-WIRE 70 MP THREE PHASE 4-WIRE 70 60

68 METER PEDESTALS 200 AMPERE RINGLESS DIRECT BURRIED RP RP CATALOG NUMBER # OF POSITIONS HEIGHT DIMENSIONS WIDTH DEPTH RP / /8 2RP / /16 WIRE SIZE LINE LOAD 1/2-13 stud 3/8-16 stud 1/2-13 stud 3/8-16 stud Contact factory or your local manufacturer s agent for special units or non-standard options. 61

69 METER PEDESTALS 320 & 400 AMPERE SINGLE PHASE MP320C350 CATALOG NUMBER UNIT AMPACITY SOCKET TYPE METER FORM CURRENT TRANS. RATIO LINE, LOAD & NEUTRAL CONNECTIONS SHIPPING WEIGHT 4-Terminal MP320S 320 Self-Contained 2S N/A 3/8 Studs 70 Pounds Lever By-Pass 4-Terminal MP320C Self-Contained 2S N/A Dual #6-350MCM 73 Pounds Lever By-Pass 5-Terminal MP400NS 400 Non-Circuit 3S 200/200:5 1/2 Studs 67 Pounds Closing 5-Terminal MP400S 400 Automatic 3S 200/200:5 1/2 Studs 67 Pounds Circuit Closing 5-Terminal MP400NC Non-Circuit 3S 200/200:5 Dual #6-350MCM 70 Pounds Closing 5-Terminal MP400C Automatic 3S 200/200:5 Dual #6-350MCM 70 Pounds Circuit Closing To convert pad mount to direct burial use sleeve catalog # for MP320-MP400 series. 62

70 METER PEDESTALS TRANSFORMER RATED 5, 6, 7, 8, & 13 TERMINAL DIMENSIONS MPO5 MPO13 CONFIGURATIONS MPO units are ringless syle and MPOR units are ring style with meters exposed for direct reading. MPE units have enclosed meters which are read through a viewing window. FRONT VIEW SIDE VIEW MPO AND MPOR OPEN-RINGLESS CATALOG # OPEN-RING CATALOG # ENCLOSED CATALOG # # OF JAWS MPO5 MPOR5 MPE5 5 MPO5N MPOR5N MPE5N 5 MPO6 MPOR6 MPE6 6 MPO6N MPOR6N MPE6N 6 MPO7 MPOR7 MPE7 7 MPO7N MPOR7N MPE7N 7 MPO8 MPOR8 MPE8 8 MPO8N MPOR8N MPE8N 8 MPO13 MPOR13 MPE13 13 MPO13N MPOR13N MPE13N lbs. 35 lbs. 43 lbs. WEIGHT To convert pad mount to direct burial use sleeve catalog # for MPE series or catalog # for MP205-MP207 series. Units with model numbers ending with the letter N have non-circuit closing sockets. All others have automatic circuit closing devices. FRONT VIEW MPE SIDE VIEW 63

71 SECONDARY CONNECTION PEDESTALS URD SINGLE & THREE PHASE NOTE: Burial Sleeve Attached PHASE PAD MOUNT CATALOG # PAD MOUNTED DIMENSIONS HEIGHT WIDTH DEPTH LINE/NEUTRAL CONNECTORS SHIPPING WEIGHT /2 9 (7) 250 MCM CU-AL 47 lbs. Note: To convert to direct burial use sleeve catalog # PHASE DIRECT BURIAL ON SLEEVE CATALOG # DIRECT BURIAL DIMENSIONS HEIGHT WIDTH DEPTH LINE/NEUTRAL CONNECTORS SHIPPING WEIGHT (7) 250 MCM CU-AL 55 lbs /2 9 (7) 250 MCM CU-AL 73 lbs (7) 250 MCM CU-AL 58 lbs. Other configurations of these units are available. Please contact the factory or your sales representative for ordering information. 64

72 SECONDARY CONNECTION PEDESTALS URD THREE PHASE VOLTAGE 600V AC RMS (MAXIMUM) ON ALL MODELS ELECTRICAL SPECIFICATIONS AND CONNECTION Model USCE has 36 inch bus length with 19 two-bolt connection positions. Model USCE has 36 inch bus length with 19 two-bolt connection positions. Model USCE has 48 inch bus length with 25 two-bolt connection positions. Single phase units have two (2) line buses and one (1) neutral and three phase units have three (3) line buses and one (1) neutral. DIMENSIONS USCE has single door access and is 40 wide, 45 high and 21 deep. USCE has two (2) doors opposite each other and is 42 x 42 square and 53 high. USCE has two (2) doors opposite each other and is 54 x 54 square and 63 high. USCE USCE USCE End Connection AMPERES Center Each Way Connection Total Buss Bar Material copper aluminum copper aluminum copper aluminum Even number catalog numbers have copper buss bar. Odd number catalog numbers have aluminum buss bar. Advise connection hole size and pattern if not standard NEMA pattern. 65

73 PAD MOUNT ENCLOSURE FAMILY 66

74 PRIMARY SECTIONALIZING PEDESTALS 200 THRU 600 AMPERE AM SERIES 15,25,35KV Pad Mount Sectionalizing Pedestal AM AM AM D Typical Optional Equipment: Mr Ouch Warning Labels ANSI Warning Labels Special Paint Color Aluminum Enclosure Anti-Condensation Compound Stainless Steel Enclosure Stainless Steel Parking Stands Ground/Tank Connectors Ground Bus Mounting Sleeve Module/Junctions Factory Installed Standard Features: 14 or 12 Gauge Galvanized Steel Stainless Steel Hardware Powder Coat Finish Munsell 7GY3.29/1.5 Green Stainless Steel Ground Nuts ANSI C Security Positive Alignment Penta-Bolt/Latching Design Lift Out Module Mounting Plates Stainless Steel Lifting Provisions 67

75 PRIMARY SECTIONALIZING ENCLOSURES ENCLOSURE SIZING SINGLE PHASE Model Number Height Width Depth Phase Max Kv Design See Note Amp Design No. Park Stands AM kV 200A 1 AM kV 200A 1 AM kV 200A 2 AM kV 200A 2 AM kV 200A 2 AM kV 200A 1 AM kV 200A 2 AM kV 200A 2 AM kV 200/600A 1 AM kV 200/600A 2 THREE PHASE Model Number Height Width Depth Phase Max Kv Design See Note Amp Design No. Park Stands AM kV 200A 2 AM kV 200A 3 AM kV 200/600A 2 AM kV 200A 3 AM D kV 200A 6 AM kV 200A 3 AM kV 200A 4 AM D kV 200A 6 AM kV 200A 3 AM kV 200/600A 3 AM kV 200/600A 3 Note: 25kV 200A rated products will accept some 200 ampere 35kV rated junctions, contact factory for details. -W 12Ga. Steel and Western Underground Approved For units to be supplied from the factory with modules installed insert the corresponding number from below: 2 way 15 kv, 200 Amp = 2 3 way 15 kv, 200 Amp = 3 4 way 15 kv, 200 Amp = 4 2 way 25 kv, 200 Amp = 5 3 way 25 kv, 200 Amp = 6 4 way 25 kv, 200 Amp = 7 For 2, 3 & 4 way 600 Amp modules, please contact manufacturers representative or factory. For units supplied with 5 & 6 way multi tap module, please contact manufacturers representative or factory. 25kv units will accomodate 15kv modules and 600A units will accomodate 200A modules. 68

76 PRIMARY SECTIONALIZING PEDESTALS BURIAL SLEEVES CATALOG NUMBER CABINET DIMENSIONS STEEL FIBERGLASS BD steel BD f-glass W D FITS SERIES GS202422W GS182422F AM GS202615W GS182615F AM GS202618W GS182618F AM GS203015W GS183015F AM GS203018W GS183018F AM GS203022W GS183022F AM GS204815W GS184815F AM GS206015W GS186015F AM GS206018W GS186018F AM D GS206418W GS186418F AM GS206622W GS186622F AM All steel burial sleeves are fabricated from 12 gauge galvanized steel and have an oven cured powder polyester finish. The sleeves are bolted together with stainless steel carriage bolts. Both the steel and fiberglass burial sleeves are designed so that when they are properly attached to the sectionalizing pedestal, the fit between the pedestal and sleeve will meet the requirements of ANSI C for Pad Mounted Equipment Enclosure integrity. 69

77 PRIMARY EQUIPMENT ENCLOSURES AT- ATB-ATP-ATBP-STYLE (NO DEADFRONT) ORDERING INFORMATION CATALOG NUMBER PREFIX MODEL SUFFIX Example: ATBP TOP VIEW WITH ROOF REMOVED ATP OR ATBP CLOSED MODEL DIMENSION IN INCHES NUMBER DEPTH AB AC AD G E F /2 2 1/ / FRONT VIEW END VIEW PREFIX PREFIX NO. POSITIONS CONFIGURATIONS AT 1, 2, or 3 Enclosure only with 2, 4 or 6 side hinged, pad lockable doors respectively. Not suitable for high voltage applications. ATB 1, 2, or 3 Enclosure only with 2, 4 or 6 side hinged, pad lockable doors respectively, with tempered hardboard insulating barriers at each door. Not suitable for high voltage applications. ATP* 1, 2, or 3 Enclosure only with 2, 4 or 6 side hinged, pad lockable and penta head bolt lockable doors respectively. Not suitable for high voltage applications. ATBP* 1, 2, or 3 Enclosure only with 2, 4 or 6 side hinged, pad lockable and penta head bolt lockable doors respectively, with tempered hardboard insulating barriers at each door. *Units are designed to meet ANSI C for Pad-Mounted Equipment Enclosure integrity. All units are REA approved. All units are shipped disassembled unless otherwise noted. Contact the factory or your representative for information and pricing on assembled units. 70

78 PRIMARY EQUIPMENT ENCLOSURES DEADFRONT DIAGRAMS ATBP ATBPR (RADIAL FEED) DEADFRONTS ATBPL (LOOP FEED) DEADFRONTS 71

79 PRIMARY EQUIPMENT ENCLOSURES ATBPR (RADIAL) ATBPL (LOOP) (LOADBREAK DEADFRONTS) ORDERING INFORMATION CATALOG NUMBER PREFIX MODEL SUFFIX Example: ATBPR TOP VIEW WITH ROOF REMOVED ATPR4253 MODEL DIMENSIONS IN INCHES NUMBER DEPTH AB AC AD G E F /2 2 1/ / FRONT VIEW DEADFRONT END VIEW PREFIX SUFFIX NO. POSITIONS CONFIGURATIONS ATBPR* 1, 2, or 3 Enclosure only with 2, 4 or 6 side hinged, pad lockable and penta head bolt lockable doors respectively, with tempered hardboard insulating barriers at each door except at the radial feed loadbreak deadfront door. ATBPL* 1, 2, or 3 Enclosure only with 2, 4 or 6 side hinged, pad lockable and penta head bolt lockable doors respectively, with tempered hardboard insulating barriers at each door except at the loop feed loadbreak deadfront door. Units are designed to meet ANSI C for Pad-Mounted Equipment Enclosure integrity. All units are REA approved. All units are shipped disassembled unless otherwise noted. Contact the factory or your representative for information and pricing on assembled units. 72

80 PRIMARY EQUIPMENT ENCLOSURES MOUNTING RAIL & PAD LAYOUT INFORMATION UNIT SIZE CATALOG NUMBER Both catalog numbers come with (1) equipment mounting rail, (2) mounting brackets, and the appropriate hardware for mounting. RECOMMENDED PAD LAYOUT FOR ANSI VERSION T-STYLE ENCLOSURES (LOAD BREAK DEADFRONT) DEPTH AB AC AD E F G H / / / /4 18 3/ / / / /4 30 3/4 8 RECOMMENDED PAD LAYOUT FOR ANSI VERSION T-STYLE ENCLOSURES DEPTH AB AC AD E F / / / / / /4 73

81 PRIMARY METERING ENCLOSURES 200 & 600 AMPERE THREE PHASE 15 OR 25 KV LIVEFRONT Unit supplied without instruments. For prewired unit contact local manufacturer represenative or factory. REAR VIEW OPEN APMP FRONT VIEW OPEN APMP

82 PRIMARY METERING ENCLOSURES 200 & 600 AMPERE SINGLE & THREE PHASE 15 OR 25 KV LIVEFRONT THREE PHASE NOMINAL VOLTAGE BIL RATING CATALOG NUMBER CONTINUOUS AMPERE RATING BUSHING WELL CONFIG. LINE LOAD 15 KV 95 KV APMP KV 95 KV APMP KV 95 KV APMP KV 95 KV APMP KV 125 KV APMP KV 125 KV APMP KV 125 KV APMP KV 125 KV APMP KV 95 KV APMP KV 95 KV APMP KV 95 KV APMP KV 95 KV APMP KV 125KV APMP KV 125KV APMP KV 125KV APMP KV 125KV APMP SINGLE PHASE NOMINAL BIL CATALOG CONTINUOUS BUSHING WELL CONFIG. VOLTAGE RATING NUMBER AMPERE RATING LINE LOAD 15 KV 95 KV APMP KV 95 KV APMP KV 95 KV APMP KV 95 KV APMP KV 125 KV APMP KV 125 KV APMP KV 125 KV APMP KV 125 KV APMP KV 95 KV APMP KV 95 KV APMP KV 95 KV APMP KV 95 KV APMP KV 125KV APMP KV 125KV APMP KV 125KV APMP KV 125KV APMP Note: 15KV 600 ampere units will not accept a 200 ampere piggy back tap. Units are designed to meet ANS1 C for Pad-Mounted Equipment Enclosure security. Above units are provided with Penta-head security bolts. To order units with Hex head security bolt change APMP to APMH (example: AMPH ). 75

83 PRIMARY METERING ORDERING GUIDE APMP SERIES 76

84 Pad-Mount Fused Dead Front Elbow Terminated with Live Front Provisions for SMU-20 Power Fuses. AFSM Series-15 kv Class 200 Amp-8.3/14.4 kv-95 kv BIL Standard Features: 12 Gauge Steel Stainless Steel Hardware Powder Coat Finish Munsell 7GY3.29/1.5 Green Live Front Safety Barriers (NESC Rule 381G) Schematic Labeling Fuse/Elbow Compartment Labels Stainless Steel Ground Nuts ANSI C Security SML-20 or SM-20 Style Fuse Mountings (For SMU-20 Fuses) Also supplied w/mcgaw NX or GE EJO fuse clips (Contact factory or local manufacturing agent for more information.) Optional Equipment: Courtesy S&C Electric Co. Bushing Well Inserts Fuse End Fittings Mr. Ouch Warning Labels ANSI Warning Labels Special Paint Color Fuse Compartment Floor Aluminum Enclosure Anti-Condensation Compound Fuse Unit & End Fittings: SM-20 or SML-20 Stainless Steel Enclosure Fuse Unit SMU-20 (Amperage and Speed Required or Part Number) Stainless Steel Parking Stands Courtesy S&C Electric Co. Opening SM-20 Power Fuse and removing SMU-20 Fuse Unite using Grappler 77

85 Pad-Mount Fused Dead Front Elbow Terminated with Live Front Provisions for SMU-20 Power Fuses. AFSM Series-15 kv Class 200 Amp-8.3/14.4 kv-95 kv BIL *SML-20 Includes: F. Uni-Rupter TM which provides 200-ampere single-pole live switching G. Fault-closing contacts that provide duty-cycle fault-closing ratings *SM-20: Similiar to image except without Uni-Rupter TM live switching capability Courtesy S&C Electric Co. *Fuse Unit and End Fittings are Optional Equipment For McGraw NX and GE-E50 fuse mounts, please contact manufacturer s representative or factory. Catalog Number Phase Class kv Line 1 Line 2 Fuse Mounting AF3122S2L22 AF3122S2L20 AF3120S2L20 AF3122S2M22 AF3122S2M20 AF3120S2M NA NA SML-20 SML-20 SML-20 SM-20 SM-20 SM-20 Load 1 Load 2 Height Width Depth NA NA NA NA When ordering with optional features specify base model number from charts and state except with optional features desired. Example: AF3122S2L22 except with Busing Well Inserts, Fuse End Fittings, and Mr. Ouch Warning Labels Line 1 Line 2 Load 1 Load 2 Mounting Methods: Fiberglass Sleeve Order # Stainless Steel Sleeve: Contact Factory Concrete Pad: Supplied and Installed by Customer 78

86 ACCESSORIES 79

87 ACCESSORIES M S BOLT-ON-HUBS (SMALL) HUB COVER PLATES CATALOG NUMBER ARP00003 ARP00004 ARP00005 ARP00006 ARP00007 SIZE 1 INCH 1 1/4 INCH 1 1/2 INCH 2 INCH 2 1/2 INCH CATALOG NUMBER SIZE ARP00002 SMALL ARP00016 LARGE BOLT-ON-HUBS (LARGE) HUB ADAPTER PLATE CATALOG NUMBER ARP00017 ARP00018 ARP00019 ARP00020 ARP00021 SIZE 2 INCH 2 1/2 INCH 3 INCH 3 1/2 INCH 4 INCH LARGE TO SMALL HUB OPENING CATALOG NUMBER ARP00015 SEALING RINGS PLUG-IN FIFTH TERMINAL CATALOG NUMBER ARP00035 SNAP TYPE CATALOG NUMBER ARP00026 SCREW TYPE CATALOG NUMBER ARP00027 SOCKET REPLACEMENT PARTS Socket Block-One Side With Caps Duplex Neutral With Caps Triplex Neutral With Caps Socket Cap Assembly Only Neutral Cap Assembly Only 100 AMP 150 AMP 200 AMP 200 AMP 2/0 250 MCM 250 MCM 350 MCM ARP00039 ARP00354 ARP00048 ARP00048 ARP00045 ARP00054 ARP00054 ARP00054 ARP00040 ARP00050 ARP00050 ARP00050 ARP00041 ARP01226 ARP01226 ARP01226 ARP00041 ARP01226 ARP01226 ARP

88 BREAKERS ARP01293 ARP00152 ARP00134 ARP01285 ARP00152 CATALOG NUMBER ARP00134 ARP00136 ARP00137 ARP00138 ARP00143 ARP00148 ARP00152 ARP00163 ARP00164 ARP00165 ARP00166 ARP01285 ARP01293 ARP01302 DESCRIPTION 50 AMP 1 POLE HEINEMANN 100 AMP 1 POLE HEINEMANN CE 50 AMP 2 POLE HEINEMANN CE 100 AMP 2 POLE HEINEMANN CE 100 AMP 2 POLE (H) W DIST CENTER 200 AMP 2 POLE 100 AMP PLUG IN HQP-2 POLE 100 AMP MAIN/50 AMP STAND BY FOR SB114DT 100 AMP MAIN/100 AMP STAND BY FOR SB114DT 200 AMP MAIN/50 AMP STAND BY FOR SB204DT 200 AMP MAIN/100 AMP STAND BY FOR SB204DT 200A CCH2200 BKR LINE/LOAD LUGS 150A CCH2150 BKR (LUGS) 125A CCH 2125 BKR (LUGS) 81

Equipment. Metering. Metering Equipment 1. Contents

Equipment. Metering. Metering Equipment 1. Contents 1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility CenterPoint Energy (Reliant & HL&P).............................

More information

Temporary Power Outlet Panels

Temporary Power Outlet Panels Power Outlet Panel Types Available ATTENTION PLEASE Siemens is proud to present our new line of temporary power products. This section describes our new product line that that will be available to order

More information

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com

Temporary Power Outlet Panels. Selection and Application Guide. www.talonmetering.com Temporary Power Outlet Panels Selection and Application Guide www.talonmetering.com 2012 Siemens Industry, Inc. www.talonmetering.com Talon meter mounting equipment For more than half a century, Talon

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

Power Outlet Panels. Product Guide

Power Outlet Panels. Product Guide Product Guide Construction and Recreational Vehicle (RV) Power Outlet Panels Vehicle Power (RV) Power Outlet Panels Power Outlet Panels Construction and RV Power Outlet Panels Product Description...1 Application

More information

CABINET OPTIONS AND DESIGNATORS

CABINET OPTIONS AND DESIGNATORS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877

More information

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC ELECTRICAL SERVICE REQUIREMENTS ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC TABLE OF CONTENTS TITLE SECTION NO. List of Approved Electric Utility Service Equipment Requirements Committee

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

Type 1, 3, & 3R Enclosures

Type 1, 3, & 3R Enclosures Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................

More information

IEC 309 INTERLOCKS NORTH AMERICAN

IEC 309 INTERLOCKS NORTH AMERICAN IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing

More information

Section M POWER LIFTS

Section M POWER LIFTS Section M POWER LIFTS December 2009 1M Index 1. 53-520244-000 Poly V Idler Assembly 2. 53-520205-000 N.A. Mounting Bracket 3. 53-520212-000 Cable Assembly 4. 53-600149-000 Wire Harness Assembly 5. 53-860322-010

More information

Mini Power-Zone Unit Substation

Mini Power-Zone Unit Substation Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3

More information

POWER WAVE 455M/STT & (CE)

POWER WAVE 455M/STT & (CE) Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-450 P-450 PARTS LIST FOR POWER WAVE 455M/STT & (CE) P-450-A P-450-A ILLUSTRATION

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems. SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W Centers Combination Catalog Number Logic Combination Sockets MC 30 40 B 1 00 S E C W ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L = Lug MB or

More information

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house

More information

TSn SERIES Surge Protective Device

TSn SERIES Surge Protective Device Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 Sales@Systems.us Fax 804.355.8900 Page: 2 of 8 Quick

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT S METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to center of meter ± 100 mm ( 4

More information

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.

More information

Parallel Redundant Uninterruptible Power Supply

Parallel Redundant Uninterruptible Power Supply 9 315 Parallel Redundant Uninterruptible Power Supply Installation/Operation Manual 164202013 Rev. D ------------------------------------------------------------------------ ------------------------------------------------------------------------

More information

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

Electronic Watt-Hour Meters Catalog

Electronic Watt-Hour Meters Catalog Catalog 1 smartbrandusa.com Ver. 15.1 Table of Contents... 3 Single Phase... 3 Two Phase... 4 Polyphase... 5... 6 Single Phase... 6 Two Phase... 7 Polyphase... 8 Accessories... 9 Meter Enclosures... 9

More information

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE A. GENERAL NOTES: Service entrance line and load conductors, conduit straps, weatherhead, lock nuts, bushings, connectors, and

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

TERMINATION ENCLOSURE OPTIONS

TERMINATION ENCLOSURE OPTIONS TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX

-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX -1-002085 CONE SETTER PLATFORM ATTACHMENT INDEX I. GENERAL EQUIPMENT : A. Intent Statement B. Cone Setter Platform II. III. 1. Understructure Frame 2. Mounting Components 3. Paint 4. Basket 5. Labels 6.

More information

ELEC ELE TR CTRIC P IC PRODUCTS RODUCT

ELEC ELE TR CTRIC P IC PRODUCTS RODUCT ELECTRIC PRODUCTS VCEP-1 ELECTRIC PRODUCTS MODEL SB STANDARD SBF SBT SB FEATURES SBST - Bottom intake, slope discharge SBT - Bottom intake, top discharge SBF - Front intake, top discharge Two piece all

More information

Type NT and Type ZWM Terminal Blocks

Type NT and Type ZWM Terminal Blocks Type NT and Type ZWM Terminal Blocks Side view of closed Sliding Link Block Sliding Link Block with white marker strip Unit-pole construction Sliding link to permit testing without disturbing wiring High

More information

Installation Instructions

Installation Instructions H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.

More information

Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX

Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-652 RETURN TO MAIN INDEX PARTS LIST FOR Flextec 450 P-652 P-652-A P-652-A ILLUSTRATION

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

APC 3Phase Power Distribution

APC 3Phase Power Distribution APC 3Phase Power Distribution North American 3 Phase Business Development Team All content in this presentation is protected 2008 American Power Conversion Corporation Objectives Understand the entire

More information

GROENEVELD AUTOMATIC GREASING SYSTEMS

GROENEVELD AUTOMATIC GREASING SYSTEMS GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991

More information

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE SHORE POWER Safely Connecting Ships to Shore SHIP-TO-SHORE SOLUTIONS FOR MILITARY & COMMERCIAL APPLICATIONS SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE ESL Power Systems, Inc. ESL has established

More information

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED Available in Sizes B C D E See Page 6 for Dimensions Kennedy Valve/Indicator Posts 17-1 INDICATOR POST STYLE 2945 A TELESCOPING

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 26 27 26, PAGE 1 SECTION 26 27 26 WIRING DEVICES

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 26 27 26, PAGE 1 SECTION 26 27 26 WIRING DEVICES KNOXVILLE, TENNESSEE SECTION 26 27 26, PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK: SECTION 26 27 26 A. The extent of wiring device work is indicated by drawings and schedules. Wiring devices are

More information

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS INSUL-TAP CONNECTORS FOR TWO S & IN-LINE SPLICERS/REDUCERS IT SERIES 1 2 3 4 Insul-Tap connectors are suitable for connecting two wires. For sizes 3/0 AWG and smaller, they are available in two styles

More information

Customer Metering and Services Guide

Customer Metering and Services Guide This document is an uncontrolled copy and may not be the most current copy. The most current copy is available at www.atcoelectric.com. This document is the property of ATCO Electric and may be updated

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 PL Series Load Centers Features and Product Offering -4-5 PL Series

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

Customer Purchased Meter Sockets & Metering Equipment

Customer Purchased Meter Sockets & Metering Equipment Customer Purchased Sockets & ing Equipment A Guide for the Proper Selection, Purchase and Use of Sockets and Equipment Purchased by Our Customers For certain electric meter installations, customers will

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained

Multiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained Overhead Meters TABLE OF CONTENTS D D Consumer Service Pole for Mobile Home Park Temporary Service -wire Single Phase D. Overhead Meter Installation - Single Phase D. Connection Diagram - Single Phase

More information

Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com

Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH

More information

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W. [previous page #: 2-18; 2-22]

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W. [previous page #: 2-18; 2-22] [previous page #: 2-18; 2-22] Combination Logic Combination Sockets MC 30 40 B 1 200 S E C W 2 ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L =

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Power Distribution & Terminal Blocks

Power Distribution & Terminal Blocks Power Distribution & Terminal Section Contents Page Selection table for SCCR PDBs & Power terminal blocks................................ 294 Power distribution blocks Series PDBFS enclosed, with high

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

Buck - Boost Transformers

Buck - Boost Transformers Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)

Number Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8

More information

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete. LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and

More information

Utility Distribution Systems

Utility Distribution Systems Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date

More information

Continuous Power... Continuous Protection

Continuous Power... Continuous Protection Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment

More information

LABORATORY CASEWORK. Table of Contents. Laboratory Cabinetry and Specialties. ADVANTAGE laboratory. Series/Model Number Specification...

LABORATORY CASEWORK. Table of Contents. Laboratory Cabinetry and Specialties. ADVANTAGE laboratory. Series/Model Number Specification... PREVIOUS VIEW LABORATORY CASEWORK Laboratory Cabinetry and Specialties Table of Contents Series/Model Number Specification... 3 Perimeter Tables... 5 s... 6-9 Steel Legs... 6-7 Wood Legs... 8-9 Student

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................

More information

9300BC SERIES Light Commercial Door Closer

9300BC SERIES Light Commercial Door Closer Light Commercial Door Closer general information The 9300BC is a durable, economically priced door closer designed for commercial exterior and interior doors such as storefront and industrial applications.

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire 9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Miniature Standard Amperage Rating - CU Wire 115 amp. 115 amp. 175 amp. 175 amp. Amperage Rating - AL Wire 90 amp. 90 amp. 135 amp.

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

Section 10 Electric Switchboards: 0 Through 600 Volts

Section 10 Electric Switchboards: 0 Through 600 Volts Section 10 Electric Switchboards: 0 Through 600 Volts 10.1. Scope This section provides specific dimensions and details for service and meter equipment that is assembled by the manufacturer in freestanding,

More information

SE-1200-EI. Operation & Parts Manual

SE-1200-EI. Operation & Parts Manual SE-1200-EI Operation & Parts Manual SE 1200 EI OWNERS MANUAL Table of Contents 1. Installation guide 2. Set-up instructions 3. Operation instructions 4. Cleaning 5. Troubleshooting 6. Parts manual 7. Electrical

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

RAY-MAX Integrated Solar Power Strip

RAY-MAX Integrated Solar Power Strip RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...

More information

280+ Mortise Mounted Series Shear Locks Special Application Solution

280+ Mortise Mounted Series Shear Locks Special Application Solution 280+ Mortise Mounted Series Shear Locks Power Plus control module overcomes gaps of up to 1/4" Low Temperature Operation 280+ TRD Locknetics provides the industry s most complete selection of electromagnetic

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

Cutler-Hammer January 1999

Cutler-Hammer January 1999 Cutler-Hammer General Description Description Safety switches have a number of applications from service entrance to branch circuit protection. They are also horsepower rated for use as motor circuit switches.

More information

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions For Slider Casement Air Conditioners Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT

More information

Miniature Circuit Breakers and Supplementary Protectors

Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information