IMPORTANT See last page for changes from VERSION 1.2. To enter programming, press [ENTER] + installer code (Installer default code )
|
|
|
- Geraldine Simmons
- 9 years ago
- Views:
Transcription
1 SOFTWARE VERSION 1.3 IMPTANT See last page for changes from VERSION 1.2 To enter programming, press [ENTER] + installer code (Installer default code ) ADDRESSES: addresses "000" to "255" ( key [10] = 0) HEXA VALUE DISPLAY (8) (4) (2) (1) No display = SKIP (empty) 10 = [0] = [A] Value of 2 ND digit = 10 ( = 10) Value of 1 ST digit = 3 ( = 3) VALUE = "30" INSTALLER CODE LOCK ([2ND][2ND] = Installer code locked, [1][1] - [F][F] = Installer code unlocked) 000: / PANEL IDENTIFIER F UPLOAD/DOWNLOAD 00 - [F][F] ([10] = 0) 001: / 002: / PC UPLOAD/DOWNLOAD PASSWD 00 - [F][F] ([10] = 0) 003: / 004: / (default code [F][F]) (default code (empty) -"SKIP") (default code (empty) -"SKIP") ACCESS CODES: INSTALLER'S CODE: Full access to programming,(all addresses except ). (default / reset code ) No access to arming/disarming and access code programming (can be used to modify installer code) 005: / 006: / 007: / PROGRAMMING MASTER AND USER CODES: [ENTER] + master code + code number (2 digit) + new code (4 or 6 digit) + [ENTER] MASTER CODE = 00 ([10][10]) (default / reset code ) USER CODES = Bypass, Away, Stay, Arm, Disarm USER CODES = Arm, Disarm USER CODES 20 = Arm ONLY REPTING CODE: (all digits from [1]-[F] are valid / [2ND] = SKIP = code is not reported) If a condition should not be reported, enter [2ND][2ND] after the required address. (default code "SKIP, SKIP" [2ND][2ND]) "TROUBLE REPT" CODES: "RESTATION" CODES: "SPECIAL REPT" CODES: 071: / No AC 077: / No AC 083: / Disarm after alarm 072: / Battery disconnected/low voltage 078: / Battery disconnect/low voltage 084: / Panic 1 073: / Maximum auxiliary current 079: / Maximum auxiliary current 085: / Panic 2 074: / Bell disconnect/max. bell current 080: / Bell disconnect/max. bell current 086: / Fire Panic 075: / Tamper / wiring 081: / Tamper / wiring 087: / Partial arming 076: / Timer loss 082: / Timer loss 088: / Test report 180: / Telephone line - 1 -
2 SYSTEM "A" (ZONES 1-12) (default code "SKIP, SKIP" [2ND][2ND]) SYSTEM "B" (EXTENSION 1-12) (default code "SKIP, SKIP" [2ND][2ND]) ALARM REPT CODES: ZONE RESTATION CODES: ALARM REPT CODES: ZONE RESTATION CODES: 089: / Zone 101: / Zone 137: / Zone 149: / Zone 090: / Zone 102: / Zone 138: / Zone 150: / Zone 091: / Zone 103: / Zone 139: / Zone 151: / Zone 092: / Zone 104: / Zone 140: / Zone 152: / Zone 093: / Zone 105: / Zone 141: / Zone 153: / Zone 094: / Zone 106: / Zone 142: / Zone 154: / Zone 095: / Zone 107: / Zone 143: / Zone 155: / Zone 096: / Zone 108: / Zone 144: / Zone 156: / Zone 097: / Zone 109: / Zone 145: / Zone 157: / Zone 098: / Zone 10A 110: / Zone 10A 146: / Zone 10B 158: / Zone 10B 099: / Zone 1 111: / Zone 1 147: / Zone 1 159: / Zone 1 100: / Zone 1 112: / Zone 1 148: / Zone 1 160: / Zone 1 ARMING REPT CODES: DISARMING REPT CODES: ARMING REPT CODES: DISARMING REPT CODES: 113: / Espload 125: / Espload 161: / User code : / User code : / Master code 126: / Master code 162: / User code : / User code : / User code 1 127: / User code 1 163: / User code : / User code : / User code 2 128: / User code 2 164: / User code : / User code : / User code 3 129: / User code 3 165: / User code : / User code : / User code 4 130: / User code 4 166: / User code : / User code : / User code 5 131: / User code 5 167: / User code : / User code : / User code 6 132: / User code 6 168: / User code : / User code : / User code 7 133: / User code 7 169: / User code : / User code : / User code 8 134: / User code 8 170: / User code : / User code 9 135: / User code 9 124: / User code : / User code 10 Enter [2ND][2ND] if no report code is required. ACCOUNT NUMBERS: [ENTER] + Installer code + [9] + 8 digit of the two system account numbers + [ENTER] / / / / / / / A / B SYSTEM "A" ACCOUNT NUMBER: SYSTEM "B" ACCOUNT NUMBER: 205: / 206: / 207: / 208: / (valid digits are [1]-[F] / [2ND] = SKIP) (default code [2ND][2ND][2ND][2ND]) If only one account number is required, the same code should be entered for both System A and System B PROGRAMMABLE OUTPUT 1: PROGRAMMABLE OUTPUT 2: 210: / 212: / 211: / 213: / TELEPHONE NUMBER PROGRAMMING: (default = [2ND][2ND]) If only one central station phone number is available, the same telephone number should be programmed for telephone number 1 and 2. TELEPHONE KEY PROGRAMMING PC DOWNLOAD TELEPHONE NUMBER: [ENTER] + Installer code + [3] + up to first 8 digits (including last digit "end of number" [TRBL]) + [ENTER], for the next 8 digits same but enter [4] instead of [3]. 181: / 182: / 183: / 184: / 185: / 186: / 187: / 188: / CENTRAL STATION TELEPHONE NUMBER 1: [ENTER] + Installer code + [5] + up to first 8 digits (including last digit "end of number" [TRBL]) + [ENTER], for the next 8 digits same but enter [6] instead of [5]. 189: / 190: / 191: / 192: / 193: / 194: / 195: / 196: / CENTRAL STATION TELEPHONE NUMBER 2: [ENTER] + Installer code + [7] + up to first 8 digits (including last digit "end of number" [TRBL]) + [ENTER], for the next 8 digits same but enter [8] instead of [7]. Switch from pulse to tone 197: / 198: / 199: / 200: / 201: / 202: / 203: / 204: / - 2 -
3 -3- AUTEPTINGTIME : (createtest report codeataddress088). Toreset real timeclock, press [ENTER] +Master or Installercode + [MEM] 209: / ADDRESS 209: Numbersofdays betweenreports Todesableautoreporting,enter" FF "([TRBL][TRBL]) ST 1 DIGITPROGRAMMING Ifdifference betweencurrenttimeand desiredreportingtime LESS THEN12H [1] ME THEN12H [2] [9] [3] [4] [5] [6] [7] [10] [11] [12] [BYP] [MEM] [TRBL] ND 2 DIGIT PROGRAMMING ADDRESS 209: Ifdifferenceinhoursbetween currenttimeanddesiredreportingtime 1or13 2or14 3or15 4or16 5or17 6or18 7or19 8or20 9or21 10or22 11or23 12or24 ND 2 digit [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] PANELOPTIONS: (default=" OFF") 214: KEY 216: KEY (handshake) (BPS) (Data) Telephoneline monitor disabled TLM trouble only Autozoneshut downdisabled Call backdisabled Reportingdisabled 5 PS1/Key switch disabled "REPTING FMATOPTIONS" Pulsedialing 1400Hz OFF /ON Answeringmachineoverridedisabled 11 Autoreporting(daysX1) 1 2 TLM troubleactivates alarm Hz 10 bps 9 20bps 1800 Hz Hz Tonedialing(DTMF) 12 (daysx4) See "Table 1" page 4 Panic1disabled Panic2disabled Fire panic3disabled Panic1silent Panic2silent 5 Panic3silent 6digit access codes OFF/ON audible 6 fire audible Key[10] fastarm disabled 8 Fast arm=regular arm "TAMPER/ZONEWIRE DEFINITION" 12zonesystem 7 4digit 9 =stayarm See "Table 2" page zone (Keys [1] &[3]) (Keys [4] &[6]) (Keys [7] &[9]) (Key[10], keyswitch) ZONEDEFINITION: (default=" OFF") Slow =ON Fast =OFF B 1 1 Silent =ON Audible =OFF B 1 1 Fire =ON Burglary =OFF B Hr. =ON Regular =OFF B 1 1 Instant = ON B 1 1 Delay = OFF Follow = ON B 1 1 Delay = OFF Stay = ON B 1 1 Regular = OFF Bypass = ON B 1 1 Bypass disabled = OFF -3-
4 - 4-3 DIGIT DECIMAL PROGRAMMING (values entered at addresses [250] - [255] contain 3 digits between "000" and "255") ([10]/[2ND] = 0) 250: / / (seconds) Exit delay (default 60 seconds) 251: / / (seconds) Entry delay 1 (default 45 seconds) 252: / / (seconds) Entry delay 2* (default 45 seconds) DECIMAL VALUE DISPLAY (8) (4) (2) (1) Total value (57) ( = 57) 253: / / (minutes) Bell cut-off time (default 5 minutes) 254: / / ( x 3 msec.) Slow zone speed (default 500 msec.) (128) (64) (32) (16) No light = 0 255: / / Number of rings before answer (default 8 rings, enter "000" panel will not answer) (Unless answering machine override is disabled, the panel will answer for answering machine dialing procedure) *Entry delay 2 is programmable at zones,, and. Key "ON" = KEYPAD TROUBLE DISPLAY [1] No battery/low battery [7] Communicator report failure [3] AC failure [8] Timer loss [4] Bell disconnect [9] Tamper or zone wiring failure [5] Maximum bell current [10] Telephone line failure [6] Max auxiliary current ON OFF Silent alarm and trouble codes reported* Audible alarm and trouble codes reported* NOTES: Initiating test report; Press [ENTER] + installer or master code + [BYP] Address 214, key [5] "ON", Report code at address 088, telephone number at address , and account number (s) at address must be programmed. Initiating Call to Espload via telephone; Press [ENTER] + installer or master code + [TRBL] Panel and PC ID numbers, (address , and PC download telephone number (address ) must be programmed) Initiating call to Espload via 74DP-1; Press [ENTER] + installer or master code + [AWAY] (Direct PC modem and panel connection) (In Espload, activate "blind dial" in modem setup.) Note: The panel must be connected to a battery. To reset timer; Press [ENTER] + installer or master code + [MEM] To stop communication attempts; Disable reporting at address 214, key [5] "OFF", then press [ENTER] + installer or master code + [STAY] Reset to default; Reset jumper "ON", [ENTER] + installer or master code + [STAY], then remove reset jumper When communicating with Espload it is not possible to enter programming mode. All other functions are accessible. For technical support please fax your name, country, fax and phone numbers in English/ French to (514) We will do our best to respond within 24 hrs
5 ZONE DESCRIPTION: Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone : Zone 10A: Zone 10B: Zone 1: Zone 1: Zone 1: Zone 1: Version 1.3 modifications from version ) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) All reportable events (up to 120 ), telephone line fail and restoration (new code at address 180) and "fail to communicate trouble" are stored in panel memory with TIME AND DATE. Telephone numbers programmed in 8 digits groups, or via address accessing. (See page 2). Panel can be reset to default without powering down by putting the reset jumper then [ENTER] + master/installer + [STAY] then remove reset jumper. (Reset will clear also previous events) Communication attempts can be canceled by disabling reporting (214 [5]) then [ENTER] + master/installer [STAY] (don't forget to enable reporting again after) User codes are programmed not via addresses but by [ENTER] + master code + code No. (2 digits) + new code 4 or 6 digits +[ENTER]. When system is stay armed and key 10 for stay arming, by pressing key 10, the system will provide exit delay and go back to stay arm after, no need to disarm and restay-arm the system. Key [10] = 0 in address mode programming. keypad buzzer follows bell output. Arm LED (red) on keypad flashes upon any alarm. When system is running on battery power, if battery reach 10.5V low battery will be reported and 20 minutes after if AC has not been restored aux. power will be cut in order to avoid over discharge of battery. When system is in 4 digit code (address 216 [7] on 6 digit code can be entered in code programming for posssible future 6 digit code usage. If the last two digits are empty ([2ND][2ND]) (default) the first two digits will automatically be inserted in the last two digits. WARRANTY Warranty conditions for the Esprit 747 may vary from country to country. Please consult your local dealer for complete warranty information. In all cases, the warranty does not cover malfunctions arising from installer error or failure to follow installation/operation instructions, nor does it apply to damages due to causes beyond the control of Paradox Security Systems Ltd., such as lightning, excessive voltage, mechanical shock or water damage. LIABILITY Under no circumstances shall Paradox Security Systems Ltd. be held liable for any direct or indirect damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation, operation or failure of this product. WARNING This security system should undergo frequent testing. However, despite regular testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected. Technical Support Fax: (514) USA technical support: LITTON - 1 (800) PARADOX SECURITY SYSTEMS LTD. Fax: (514) Canada technical support: MSP - 1 (800) Industrial Blvd, St Eustache, Quebec, Canada J7R 5V3-5 -
616, 626, 636 & 646 Keypads
616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15
System Programming Guide
& System Programming Guide Software Versions 5.0 (728ULT) and 5.0 (738ULT) Installer Code (default - 728 Ultra: 282828; 738 Ultra: 383838) Full access to programming, except user access codes (PINs). No
System Programming Guide (728ULT)
System Programming Guide (728ULT) Software Version 4.4 Installer Code (Default: 282828) Full access to programming, except user access codes (PINs). No access to arming/disarming. Use only numeric keys
728 SERIES REFERENCE & INSTALLATION MANUAL 728+ VERSION 3.2. 728 series
728 SERIES 728+ VERSION 3.2 728 series REFERENCE & INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION... 2 About This Manual... 2 Features... 2 Specifications... 3 Accessories and Keypads... 3 About Paradox...
642 LCD Keypad User Manual
642 LCD Keypad User Manual TABLE OF CONTENTS Introduction...3 Legend... 3 Basic Operation...5 Keypad Indicator Lights... 5 Visual Feedback... 5 Auditory Feedback... 6 Info List... 7 Access Codes...8 User
Reference & Installation Manual
& Versions 4.4 (728ULT) & 4.1 (738ULT) 728ULT 738ULT Reference & Installation Manual Table of Contents Introduction... 1 About This Manual... 1 New Features... 1 Main Features... 1 Specifications... 1
CA60 Plus Software Version 3.1 User Manual May 2000
TeleT eletek ek CA60 Plus Software Version 3.1 User Manual May 2000 CONTENTS 1. CA60Plus Keypad... 3 1.1. LED display... 3 1.2. Keys... 4 1.3. Combinations of Keys... 4 1.4. Audible Indication... 4 2.
Solution-16 Operators Manual ISSUE 1.60
Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided
1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE Software Version 2.1
1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE Software Version 2.1 DEFAULT INSTALLER CODE 000000 (see section [281] on page 18) DEFAULT SYSTEM MASTER CODE 123456 (see section [301] on page 18)
INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD
INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD TABLE OF CONTENTS SYSTEM INFORMATION 2 INTRODUCTION 3 Test Your System Regularly...3 Important Notice...3 Glossary...3 BASIC OPERATION 4 Arming Your System...4
User s Information Guide R1A
HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes
PC Tab Security System INSTRUCTION MANUAL
PC Tab Security System INSTRUCTION MANUAL This manual is intended as a Quick Start manual covering the basic functions that have been enabled on the alarm panel. The alarm panel is capable of extensive
Control panel software versions 2.00 and beyond.
ESPRIT BURGLAR ALARM CONTROL PANEL Welcome to the world of ESPRIT technology. Your Esprit control panel has been designed with ease of use and simplicity in mind. We ve developed a highly advanced technology
PK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-5587722 +972-3-5500442 [email protected] http://www.pima-alarms.com
Solution 880 Operators Manual ISSUE 1.10
Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA408O DOCUMENT ISSUE 1.10 Printed 25 May 2001 This documentation is provided
ICP-CC488. Installation Guide ICP-CC488 Control Panel
ICP-CC488 EN Installation Guide ICP-CC488 Control Panel ICP-CC488 Installation Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems,
10-Zone Spectra LED Keypads
10-Zone Spectra LED Keypads 1686V 1686H User s Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your
VR8. User Guide Intruder Alarm System
VR8 EN User Guide Intruder Alarm System VR8 User Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights
!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40
!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40 MA8XXI 34&0(5167(410(877'(&'9#$:7:(;"
TABLE OF CONTENTS FEATURES
TABLE OF CONTENTS FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2 PC1500RK Keypad... 2
INSTRUCTION MANUAL PC255O
INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment
LCD and 16-Zone LED Keypads. User s Manual
LCD and 16-Zone LED Keypads 1689 1641 16-Zone LED Keypad LCD Keypad User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION...3 2.0 BASIC OPERATION...4 2.1 Keypad Indicator Lights... 4 2.2 Visual Feedback...
XP-600 Programming Instructions
Hexadecimal Data Entry To Enter a hexadecimal digit enter the following A= A1 D= A4 B= A2 E= A5 C= A3 F= A6 XP-600 Programming Instructions Note These Programming Instructions are intended to be used in
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
System Manager s Manual
LCD Keypad DGP2-641B / DGP2-641RB DGP2-641 / DGP2-641R System Manager s Manual Also includes Operating Instructions Table of Contents Introduction... 1 Legend... 1 Basic Operation... 1 Auditory Feedback
Cerber C612 12-Zone and 2-Partition Burglary Control Panel For your home and office
Cerber C612 12-Zone and 2-Partition Burglary Control Panel For your home and office Doc 10905/ 09.2005/ version 2.0 User s Guide 1. INTRODUCTION...4 General Features...4 User Codes...4 Installer Codes...5
IDS X-Series User Manual 700-398-01D Issued July 2012
1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...
How To Use An F145C-1 With A Sim Sims 2 (Aq) And A Sims 1 (Aux) (Aipa) (For Aq) (F145C) (Ios) (Power
First Alert FA145 Installer Notes M. Leuck 1. Programming can only be done by 6139 Alpha keypads, standard 6128 keypad cannot be used to program zones 2. Program new Master Code in section *20 (old version)
CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com
CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
Digiplex LCD Keypad DGP-641. User s Manual
Digiplex LCD Keypad DGP-641 User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION... 7 1.1 Legend... 7 2.0 BASIC OPERATION... 8 2.1 Auditory Feedback (Beep Tones)... 9 2.2 Keypad Indicator Lights... 9 2.3
TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2
TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad
First Alert FA140C/142C Installer Notes M. Leuck
First Alert FA140C/142C Installer Notes M. Leuck 1. Programming can only be done by 6139 Alpha keypads, standard 6128 keypad cannot be used to program zones 2. Program new Master Code in section *20 (old
MICROPROCESSOR HOME - SECURITY SYSTEM Home4
MICROPROCESSOR HOME - SECURITY SYSTEM Home4 The system is useful for protection of small buildings - living places, shops, offices, store places etc. including up to 8 separate zones. It has built-in power
INSTALLATION MANUAL PC2525. Version 1.1
INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...
Magellan All-in-one Wireless Security System
Magellan All-in-one Wireless Security System MG6250 Console Version 1.0 Menu Programming Guide Introduction The MG6250 All-in-one Wireless Console is a two-partition, 64-zone wireless console, offering
Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand
Elite 8D/Lite Version 8 Zone Controller 8 Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand 2 CONTENTS Page No. INTRODUCTION 4 About your Alarm 4 OPERATING
32 Zone Wireless Transceiver Security Systems MG5000 V4.0 MG5050 V4.0. 5 to 32 Zone Expandable Security Systems SP5500 V4.0 SP6000 V4.0 SP7000 V4.
32 Zone Wireless Transceiver Security Systems MG5000 V4.0 MG5050 V4.0 5 to 32 Zone Expandable Security Systems SP5500 V4.0 SP6000 V4.0 SP7000 V4.0 Always Armed, Never Disarmed Programming Guide PARADOX.COM
How To Control A Car Alarm On A Car With A Remote Control System
MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock
How To Use A Powerline On A Iphone Or Ipa (Aero) With A Powerpoint (A2) On A Blackberry) With An Iphones 2 (A3) Or Ipad (A4) With
NOTE After 15 minutes of keypad inactivity the keypad will emit a steady tone indicating the panel has been left in Dealer Program Mode. Enter Dealer Code to exit or press the C key to return to Dealer
EVO48 EVO192. User Guide
EVO48 EVO192 User Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments. Table of Contents
Solution 862 Operators Manual. Issue 1.00
Solution 862 Operators Manual Issue 1.00 Solution 862 Operators Manual Copyright 1998 by Electronics Design and Manufacturing Pty Limited, SYDNEY, AUSTRALIA Document Part Number MA406O Document Issue
CONTENTS 4. HOW TO UNSET THE PANEL...7
Pi-8 USER MANUAL CONTENTS 1. THE KEYPAD AND ITS OPERATION...3 1.1 DESCRIPTION OF THE KEYPAD LEDS... 3 1.1.1 READY LED (RED)...3 1.1.2 TAMPER LED (RED)...3 1.1.3 POWER LED (GREEN)...3 1.1.4 CIRCUIT LEDs
LCD5500Z / PKP-LCD v3.x Installation Instructions
LCD5500Z / PKP-LCD v3.x Installation Instructions TM Introduction The LCD5500Z / PKP-LCD keypad displays system status using an LCD screen. The keypad can be used on PowerSeries security systems with up
Control/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest
Automatic Telephone Dialer TD-101(W)
Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages
Application Notes. 1.21 Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4.
Application Notes 1.21 Partition Programming (PC1616/1832/1864 V4.2) Panels: POWER SERIES (PC1616/1832/1864 V4.2) Overview: The PC1616 supports 2 true partitions. The PC1832 supports 4 true partitions.
Vision Security System OWNER MANUAL V-LCD1
Vision Security System OWNER MANUAL V-LCD1 Congratulations on your purchase of the OPTEX Vision security system. Vision is an advanced microprocessor based alarm system which provides fire and burglar
Zone Assignment. PC5010 Zone 1-16 Assignment. System Parti- Zone Label Zone Zone Attributes Serial Number. Zone tion Type (Wireless)
Zone Assignment PC5010 Zone 1-16 Assignment System Parti- Zone Label Zone Zone Attributes Serial Number Zone tion Type (Wireless) Wireless Tx Del. Swing. 1 2 Force Bypass Chime Steady/Pulsed Audible/Silent
Microprocessor Home Security System
numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a
PRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
ELECTRONIC ENGINEERING LTD. PowerWave-16. 16 zone Control panel Communicator. User s Operating and Programming Guide. Version: 6.
ELECTRONIC ENGINEERING LTD. PowerWave-16 16 zone Control panel Communicator User s Operating and Programming Guide Version: 6.28 P/N 7121240 Rev c N.A May 2003 Contents Introduction... 4 Meet the Crow
NX-8V2 Control Panel Installation Manual
NX-8V2 Control Panel Installation Manual P/N I-NX8V2-IM REV H ISS NOV12 Copyright Disclaimer Trademarks and patents Intended use Contact information Customer support 2012 UTC Fire & Security Americas Corporation,
Security module CG2 User manual
Security module CG2 User manual TRIKDIS, JSC Draugystes str. 17, LT-51229 Kaunas LITHUANIA E-mail [email protected] Web http://www.trikdis.lt This manual is furnished to help You understand Your security
How To Set Off An Alarm On A Car With A Car Alarm On It
AUTO SECURITY SYSTEM USER S OPERATION GUIDE FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference,
ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide
ICP-CC488 EN Quick Reference Guide ICP-CC488 Control Panel ICP-CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security
NetworX NX-8 Control/Communicator Installation Manual
NetworX NX- Control/Communicator Installation Manual Table of Contents General Description... Ordering Information... Feature Definitions... - Programming the LED Keypads... Programming the NX-... 9- Types
IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18
INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay
INSTRUCTION MANUAL LCD-6OO SECURITY STATION
INSTRUCTION MANUAL 1993 Digital Security Controls Ltd. 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6 Printed in Canada 29000144 R1 LCD-6OO SECURITY STATION Table of Contents Introduction 1 About
User's Manual. For use with ProSYS 16, ProSYS 40, and ProSYS 128
User's Manual For use with ProSYS 16, ProSYS 40, and ProSYS 128 Important Notice This manual is delivered subject to the following conditions and restrictions: This manual contains proprietary information
VEHICLE SECURITY SYSTEM G25/G20
VEHICLE SECURITY SYSTEM G25/G20 Limited Lifetime Warranty This vehicle security system is warranted to the original purchaser, to be free from defects in material and workmanship. The manufacturer will
ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide
ICP-CC488 EN User s Guide ICP-CC488 Control Panel ICP-CC488 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc. ( Bosch
SCORPION Z16040C Alarm Controller User Instructions
SCORPION Z16040C Alarm Controller User Instructions Thank you for choosing to purchase this micron security alarm controller. Micron product is manufactured to exacting quality standards. We understand
INSTRUCTION MANUAL SOFTWARE VERSION 1.0R
INSTRUCTION MANUAL SOFTWARE VERSION 1.0R FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment.
Always Armed, Never Disarmed User Guide
E55 E65 Always Armed, Never Disarmed User Guide Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your
astec Integrated Alarm System USER GUIDE
astec Integrated Alarm System USER GUIDE 020008599 CONTENTS Full Set, Part Set and Disarm 3 Instant Full Set 3 Part Set with exit time 4 Bell Test 4 Bypassing zones 4 Switch Lights on/off 4 Bypass (24
System Introduction S E C T I O N 1
System Introduction S E C T I O N 1 1.1 Specifications Flexible Zone Configuration Six fully programmable zones; system expandable to eight zones using keypad zone inputs and wireless zones 38 access codes:
How To Control A Control Panel With A Pager And A Power Control Unit
V1.5 96-Zone Expandable Security and Access Control Panel DGP-NE96 DGP-NE96 Reference and Installation Manual www.paradox.ca Table of Contents Introduction... 1 Features... 1 Specifications... 1 Installation...
Users Guide to Keypad Functions
Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &
Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...
TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6
Program Entry Guide. Control Panels
EN Program Entry Guide Control Panels D6412/D4412 Program Entry Guide EN 2 Documentation Conventions Type Styles Used in this Manual To help identify important items in the text, the following type styles
ABUS WIRELESS ALARM SYSTEM
ABUS WIRELESS ALARM SYSTEM These installation instructions are published by Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing/Mühlhausen. All rights including translation reserved. Reproductions
Digiplex LCD Keypad DGP-641. User s Manual
Digiplex LCD Keypad DGP-641 User s Manual 1.0 TABLE OF CONTENTS INTRODUCTION...6 1.1 Legend... 6 BASIC OPERATION... 7 2.1 Auditory Feedback (Beep Tones)... 8 2.2 Keypad Indicator Lights... 8 2.3 LCD Screen...
Solution 16 plus. User Guide Security System
Solution 16 plus EN Security System Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights are reserved.you may download
SPECIAL CONTROL BUTTON FUNCTIONS
Operating Guide 1 2 3 CONTENTS Page No. OPERATING YOUR ALARM 5 General Information 5 Arming the Alarm 5 Disarming the Alarm 6 Arming in Stay Mode 7 Disarming Stay Mode 8 Bypassing Zones 8 Manual Panic,
1R / 4-BUTTON SERIES
Button 1 1R / 4-BUTTON SERIES VEHICLE SECURITY SYSTEM Standard Features: Two 4-Button Remote Transmitters Status indicator (LED) Valet / override switch Multi-tone siren Dual stage impact detector Remote
SECURITY SYSTEM NOTES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary
Ademco Vista-20P/First Alert FA-168C Basic Commands
Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel,
Destiny 4100. Destiny 4100. Owners Manual
Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6
Digiplex Control Panel (DGP-848) - V4.1
Digiplex Control Panel (DGP-848) - V4.1 DGP-848 Reference and Installation Manual Includes DGP2-641BL/RB Installation Instructions Table of Contents Introduction... 1 Features... 1 Specifications... 1
GE Concord 4 Quick User Guide
GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide Page 1 Before Calling Is the keypad beeping? Press *. This will silence the beeping and let you know where the trouble is. Is there a flashing
INSTRUCTION MANUAL DSC 1550
INSTRUCTION MANUAL DSC 1550 A WORD ABOUT YOUR SYSTEM The PC1550 Security System has been designed to give you the greatest possible flexibility and convenience. Read this manual carefully and become familiar
32-Zone Wireless Transceiver Security Systems. 4 to 32-Zone Expandable Security Systems. Programming Guide. MG5000 Version 4.7 MG5050 Version 4.
32-Zone Wireless Transceiver Security Systems MG5000 Version 4.7 MG5050 Version 4.92 4 to 32-Zone Expandable Security Systems SP5500 SP6000 SP7000 Version 4.92 SP4000 SP65 Version 5.12 Programming Guide
Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function
WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call SPECIAL CODES "Chime" Digit 1 "Partial Arm" Digit 2 "Quick Arm" Digit 3 ENTRY / EXIT DELAY TIMES Exit Delay Time Entry Delay Time Secondary
System Manager s Manual for DGP-848 Systems
LCD Keypad Module DGP2-641/DGP2-641R DGP2-641BL/DGP2-641RB System Manager s Manual for DGP-848 Systems Also includes Operating Instructions Table of Contents Introduction... 1 Legend... 1 Basic Operation...
Solution-8 Control Panel
Solution-8 Control Panel Issue 3c September 1994 Copyright 1994-1995 All rights reserv (MA 800 O) Important Note As there are many different types of consoles available for use with this control panel,
AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions
AIM TECHNICAL MANUAL AIM-1450HW HARDWIRE PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING See page 9 for Activation Instructions AIM Technical Manual - AIM 1450HW AIM-1450HW HARDWIRE ABOUT
ACP10 10 Zone Intruder Alarm System
ACP10 10 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 4 Remote Keypads... 5 LED Remote Keypad... 5 LCD Remote Keypad... 5 USB-Link...
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
SPECIAL CODES AUXILIARY CODES SYSTEM NOTES
Installing/Service Company Monitoring Center SPECIAL CODES Master Code Duress Code AUXILIARY CODES "Quick Arm" " Chime" 08 02 09 03 10 04 11 05 12 06 13 07 14 SYSTEM NOTES Exit Delay Time Entry Delay Time
INTRODUCTION 2 Features... 2 Specifications... 2
TABLE OF CONTENTS INTRODUCTION 2 Features... 2 Specifications... 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Wiring... 4 Burglary Zone Wiring... 4 Auxiliary Power Connection... 4
Magellan All-in-one Wireless Security System
Magellan All-in-one Wireless Security System MG6250 Console Version.0 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed
PowerWave-8. Users Operating and Programming Guide Version 8.64. 8 zone Control panel Communicator
ELECTRONIC ENGINEERING LTD. PowerWave-8 8 zone Control panel Communicator Users Operating and Programming Guide Version 8.64 P/N 7101261 Rev. C N.A July 2002 2 Contents Introduction...5 Meet the Crow Alarm
CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual
SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL
ACTIVE 5 ENGINEERING MANUAL
ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features
SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS
SECURITY SYSTEM NOTES Installing/Service Company For Service Call SPECIAL CODES Master Code Duress Code "Quick Arm" Digit "Chime" Digit "Entry-Guard" Digit AUXILIARY ARM / DISARM CODES 02 12 22 03 13 23
NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL
NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia