1 Y203EN205+MotionDrives+Cat.book Seite 223 Freitag, 10. Juni :05 16 MX2 Born to drive machines Current vector control High starting torque: % at 0.5 Hz Double rating VT 120%/1 min and CT 150%/1 min Speed range up to 1000 Hz IM & PM motor control Torque control in open loop vector Positioning functionality Builtin application functionality (i.e. Brake control) Builtin logic programing Safety embedded compliant with ISO (double input circuit and external device monitor EDM) USB port for PC programming 24 VDC backup supply for control board Fieldbus communications: Modbus, DeviceNet, Profibus, Componet, Ethercat, MII and Ethernet/IP PC configuration tool: CXDrive RoHS, CE, cuus Frequency inverters Ratings V Class singlephase 0.1 to 2.2 kw V Class threephase 0.1 to 15.0 kw 400 V Class threephase 0.4 to 15.0 kw System configuration Power supply MCCB USB cable Input C reactor Remote operator extension cable CXDrive CXOne CD 5 lines remote operator Installation accesory Filter Communication option board MX2 Braking resistor DC reactor Choke Motor Output C reactor Ground MX2 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE 223

2 Specifications Type designation 3 G 3 MX2B002E@ MX2 series C: IP54 ready for customization : IP20 D: IP54 (Includes Class 2 EMC filter) Voltage: B: Singlephase VC 2: Threephase VC 4: Threephase 400 VC E: Europe standard Max. applicable motor output 002: 0,2 kw ~ 150: 15,0 kw V class Motor kw 2 Output characteristics Power supply Singlephase: 3G3MX2@ B001 B002 B004 B Three phase model use forcedaircooling but single phase model is self cooling. 2. Based on a standard 3Phase standard motor. 3. bove 400 Hz with some function limitation. 4. Forced air cooling for IP54 models B015 B022 Threephase: 3G3MX2@ For VT setting For CT setting VT Inverter capacity kv CT VT CT Rated output current () at VT Rated output current () at CT Max. output voltage Proportional to input voltage: V Max. output frequency 1000 Hz 3 Rated input voltage and frequency Singlephase..240 V 50/60 Hz 3phase..240 V 50/60 Hz llowable voltage fluctuation 15%..+10% llowable frequency fluctuation 5% Braking torque t shorttime deceleration t capacitor feedback 100%: <50Hz 50%: <60Hz Cooling method Self cooling 4 70%: <50Hz 50%: <60Hz pprox 20% Forcedaircooling 400 V class Motor kw 1 Output characteristics Power supply Threephase: 3G3MX2@ For VT setting For CT setting VT Inverter capacity kv 380 CT VT CT Rated output current () at VT Rated output current () at CT Max. output voltage Proportional to input voltage: V Max. output frequency 1000 Hz 2 Rated input voltage and frequency 3phase V 50/60 Hz llowable voltage fluctuation 15%..+10% llowable frequency fluctuation 5% Braking torque t shorttime deceleration *3 t capacitor feedback Cooling method Self cooling 3 1. Based on a standard 3Phase standard motor. 2. bove 400 Hz with some function limitation. 3. Forced air cooling for IP54 models 100%: <50Hz 50%: <60Hz 70%: <50Hz 50%: <60Hz Forcedaircooling 224 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE Frequency inverters

3 Specifications Commom specifications Control functions Functionality Protection functions mbient conditions Model number Specifications 3G3MX2 Control methods Phasetophase sinusoidal pulse with modulation PWM (Sensorless vector control, V/F) Output frequency range Hz (with restrictions above 400Hz) Digital set value: ±0.01% of the max. frequency Frequency precision nalogue set value: ±0.2% of the max. frequency (25 ±10ºC) Digital set value: 0.01 Hz Resolution of frequency set value nalogue set value: 1/1000 of maximum frequency Resolution of output frequency 0.01Hz Starting torque % / 0.5 Hz Dual rating: Overload capability Heavy duty (CT): 150% for 1 minute Normal Duty (VT): 120% for 1 minute Frequency set value 0 to 10 VDC (10 K ), 4 to 20 m (100 ), RS485 Modbus, Network options V/f Characteristics Constant/ reduced torque, free V/f FW (forward run command), RV (reverse run command), CF1~CF4 (multistage speed setting), JG (jog command), DB (external braking), SET (set second motor), 2CH (2stage accel./decel. command), FRS (free run stop command), EXT (external trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), T (analog input selection), RS (reset), PTC (thermistor thermal protection), ST (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (remote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control), SF1~SF7 (multistage speed setting; bit operation), OR (overload restriction), T (torque limit enable), TRQ1 (torque limit Inputs signals changeover1), TRQ2 (torque limit changeover2), BOK (Braking confirmation), C (D cancellation), PCR (position deviation clear), DD (add frequency enable), FTM (force terminal mode), TR (permission of torque command input), KHC (Cumulative power clear), MI1~MI7 (general purpose inputs for EzSQ), HD (analog command hold), CP1~CP3 (multistageposition switches), OR (limit signal of zeroreturn), ORC (trigger signal of zeroreturn), SPD (speed/position changeover), GS1~GS2 (STO inputs, safety related signals), 485 (Starting communication signal), PRG (executing EzSQ program), HD (retain output frequency), ROK (permission of run command), EB (rotation direction detection of Bphase), DISP (display limitation), OP (option control signal), NO (no function) RUN (run signal), F1~F5 (frequency arrival signal), O,O2 (overload advance notice signal), OD (PID deviation error signal), (alarm signal), OTQ (over/under torque threshold), UV (undervoltage), TRQ (torque limit signal), RNT (run time expired), ONT (power ON time expired), THM (thermal warning), BRK (brake release), BER (brake error), ZS (0Hz detection), DSE (speed deviation excessive), POK (positioning completion), ODc (analog voltage input disconnection), OIDc (analog current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), OG1~OG3 (ogic output signals), WC (capacitor life warning), WF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warn Output signals ing), OC (ow load), MO1~MO3 (general outputs for EzSQ), IRDY (inverter ready), FWR (forward operation), RVR (reverse operation), MJ (major failure), WCO (window comparator O), WCOI (window comparator OI), FREF (frequency command source), REF (run command source), SETM (second motor in operation), EDM (STO (safe torque off) performance monitor), OP (option control signal), NO (no function) FreeV/f, manual/automatic torque boost, output voltage gain adjustment, VR function, reduced voltage start, motor data selection, autotuning, motor stabilization control, reverse running protection, simple position control, simple torque control, torque limiting, automatic carrier frequency reduction, energy saving operation, PID function, nonstop operation at instantaneous power failure, brake control, DC injection braking, dynamic braking (BRD), frequency upper and lower limiters, jump frequencies, curve accel and decel (S, U, inversed U,ES), 16stage speed profile, fine adjustment of start Standard functions frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2stage accel/decel, stop mode selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/hold function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display restriction, password function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry, frequency pullin restart, frequency matching, overload restriction, over current restriction, DC bus voltage VR nalogue inputs 2 analogue inputs 0 to 10 V (10 K ), 4 to 20 m (100 ) Pulse train input terminal 0 to 10 V (up to 24 V), up to 32 khz ccel/decel times 0.01 to s (line/curve selection), 2nd accel/decel setting available Status indicator ED s Run, Program, larm, Power, Hz, mps Display Digital operator: vailable to monitor 32 items: frequency reference, output current, output frequency... Motor overload protection Electronic Thermal overload relay and PTC thermistor input Instantaneous overcurrent % of rated current Dual rating: Overload Heavy duty (CT): 150% for 1 minute Normal Duty (VT): 120% for 1 minute Overvoltage 800 V for 400 V type and 400 V for V type Undervoltage 345 V for 400 V type and V for V type Momentary power loss Following items are selectable: larm, decelerates to stop, decelerates to stop with DC bus controlled, restart Cooling fin overheat Temperature monitor and error detection Stall prevention level Stall prevention during acceleration/deceleration and constant speed Ground fault Detection at poweron Power charge indication On when power is supplied to the control part Degree of protection IP20, Varnish coating on PCB & IP54 (For 3G3MX2D@ type) mbient humidity 90% RH or less (without condensation) Storage temperature 20ºC..+65ºC (shortterm temperature during transportation) mbient temperature 1 10 C to 50ºC (Both the carrier frequency and output current need to be reduced over 40ºC) Installation Indoor (no corrosive gas, dust, etc.) Installation height Max m Vibration 5.9 m/s 2 (0.6G), 10 to 55 Hz 1. Some types of 3G3MX2D requires special derating depending on installation conditions and carrier frequency selected. Check the manual for details Frequency inverters MX2 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE 225

4 R f R l w Q?@ h m u d q s d q r s n o q d r d s q t m g š o v q ` k l ` o q f R f R l w Q q t m r x r c q h u d?@ h m u d q s d q r s n o q d r d s q t m g š o v q ` k l ` o q f R f R l w Q?@ h m u d q s d q q t m r s n o q d r d s q t m g š o v q ` k l ` o q f IP20 W1 W 4.5 W W1 2d W W1 2d q t m H1 H H1 H H1 H 5 t t D Figure 1 D Figure 2 D1 D Figure 3 2,6 D1 D1 D2 D2 Voltage class Singlephase V Threephase V Threephase 400 V Inverter model 3G3MX2@ Figure in mm W W1 H H1 t D D1 D2 d Weight (KG) B001 1 B B B B B Option board 31.3 Note: Option boards could be fitted inside the IP54 model 226 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE Frequency inverters

5 IP Figure Figure Figure Figure 4 Frequency inverters Figure 1 Figure 2 Figure 3 Figure 4 3G3MX2DB001E 3G3MX2DB001EC 3G3MX2D2055EC 3G3MX2D2110EC 3G3MX2DB002E 3G3MX2DB002EC 3G3MX2D2075EC 3G3MX2D2150EC 3G3MX2DB004E 3G3MX2DB004EC 3G3MX2D4055EC 3G3MX2D4110EC 3G3MX2D1E 3G3MX2DB007EC 3G3MX2D4075EC 3G3MX2D4150EC 3G3MX2D2E 3G3MX2DB015EC 3G3MX2D4E 3G3MX2DB022EC 3G3MX2D7E 3G3MX2D1EC 3G3MX2D2EC 3G3MX2D4EC 3G3MX2D7EC 3G3MX2D2015EC 3G3MX2D2022EC 3G3MX2D2037EC 3G3MX2D4004EC 3G3MX2D4007EC 3G3MX2D4015EC 3G3MX2D4022EC 3G3MX2D4030EC 3G3MX2D4040EC MX2 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE 227

6 INE OD Rasmi footprint filters 1x V 3x V 3x400 V Rasmi model W H X Y M XFIM1010RE M4 XFIM1014RE M4 XFIM1024RE M4 XFIM2010RE M4 XFIM2020RE M4 XFIM2030RE M4 XFIM2060RE M5 XFIM2080RE M5 XFIM2100RE M6 XFIM3005RE M4 XFIM3010RE M4 XFIM3014RE M4 XFIM3030RE M5 XFIM3050RE M5 Schaffner footprint filters H W Rasmi model W H X Y B M 1x V XFIM1010SEV M5 XFIM1024SEV M5 XFIM2010SEV M5 XFIM2020SEV M5 3x V XFIM2030SEV M5 XFIM2060SEV M5 XFIM2080SEV M5 XFIM2100SEV M5 XFIM3005SEV M5 XFIM3010SEV M5 3x400 V XFIM3014SEV M5 XFIM3030SEV M5 XFIM3050SEV M5 XFIM1024SEV1 1' 1 N' N B Y X Input C reactor Voltage V 400 V B2 C2 D E F Weight kg XRI DE XRI00880DE XRI DE XRI DE XRI DE XRI DE XRI DE XRI DE DC Reactor Voltage V Weight B C D E F G H kg XRC DE XRC DE XRC DE XRC DE 1.60 XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE Frequency inverters

7 Voltage 400 V Weight B C D E F G H kg XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE Output C Reactor Voltage V 400 V Weight B2 C2 D E F kg XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO00320DE Frequency inverters Chokes D diameter Motor kw Weight kg W H X Y m XFER2102RE 21 < XFER2515RE 25 < XFER5045RE 50 < W Y X Ø m H Ø d MX2 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE 229

8 Resistor dimensions XREM00K1 Fig 1 Fig 2 Fig 3 Fig 4 Type Fig. Weight H M I T kg XREM00K1400IE XREM00K2070IE XREM00K2120IE XREM00K2IE XREM00K4075IE 1 XREM00K4035IE XREM00K4030IE XREM00K5120IE XREM00K6100IE XREM00K6035IE XREM00K9070IE XREM00K9020IE XREM00K9017IE XREM01K9070IE XREM01K9017IE XREM02K1070IE XREM02K1017IE 4 XREM03K5035IE XREM03K5010IE 230 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE Frequency inverters

9 Standard connections Breaker, MCCB or GFI Power source, 3phase or 1phase, per inverter model Thermistor Meter Meter Intelligent inputs, 7 terminals NOTE: For the wiring of intelligent I/O and analog inputs, be sure to use twisted pair/ shielded cable. ttach the shielded wire for each signal to its respective common terminal at the inverter end only. Input impedance of each intelligent input is 4.7k Forward Short bar (Source type) GND for logic inputs nalog reference 0~10VDC 4~20m Pulse train input 24Vdc 32kHz max. GND for analog signals R (1) S (2) T N(3) 24V P /GS1 4/GS2 5/PTC 6 7/EB PC EO M H O OI E Input circuits MX2 [5] configurable as discrete input or thermistor input pprx.10k pprx.100 Output circuit Termination resistor ( ) (Change by slide switch) 10Vdc + RS485 transceiver RS485 transceiver USB transceiver Option port controller U(T1) V(T2) W(T3) PD/+1 P/+ RB N/ /EDM Open collector output Freq. arrival signal oad 12 oad + CM2 GND for logic outputs SP SN Brake resistor (optional) Relay contacts, type 1 Form C RJ45 port (Optional operator port) Option port connector Motor DC reactor (optional) Braking unit (optional) Serial communication port (RS485/ModBus) USB (minib) port (PC communication port) USB power: Self power Frequency inverters Terminal Block Specifications Terminal Name Function (signal level) R/1, S/2, T/3 U/T1, V/T2, W/T3 PD/+1, P/+ P/+, N/ P/+, RB Main circuit power supply input Inverter output Used to connect line power to the drive. Drives with singlephase V input power use only terminals R/1 and N (T/3), terminal S/2 is not available for these units Used to connect the motor External DC reactor terminal Normally connected by the shortcircuit bar. Remove the shortcircuit bar between +1 and P/ +2 when a DC reactor is connected. Regenerative braking unit terminal Connect optional regenerative braking units (If a braking torque is required) Braking resistor terminals Grounding Connect option braking resistor (if a braking torque is required) For grounding (grounding should conform to the local grounding code.) MX2 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE 231

10 Control Circuit Type No. Signal name Function Signal level PC Intelligent input common Source type: connecting [P24] to [1][7] turns inputs ON Sink type: connecting [] to [1][7] turns inputs ON P24 Internal 24 VDC 24 VDC, 30m 24 VDC, 100 m Digital input signals 1 Multifunction Input selection 1 Factory setting: Forward/ Stop 2 Multifunction Input selection 2 Factory setting: Reverse/ Stop 3/GS1 Multifunction Input selection 3 / safe stop input 1 Factory setting: External trip 4/GS2 Multifunction Input selection 4 / safe stop input 2 Factory setting: Reset 5/PTC Multifunction Input selection 5 / PTC thermistor input Factory setting: Multistep speed reference 1 6 Multifunction input selection 6 Factory setting: Multistep speed reference 2 27 VDC max 7/EB Multifunction input selection 7 / Pulse train input B Factory setting: Jog Pulse train nalog input signal Digital output signals Multifunction Input selection common (in upper row) E Pulse train input Factory setting: Speed reference EO Pulse train output D frequency H Frequency reference power supply 10 VDC 10 m max O Voltage frequency reference signal 0 to 10 VDC (10 k ) OI Current frequency reference signal 4 to 20 m (250 ) Frequency reference common (bottom row) 11/EDM Discrete logic output 1 / EDM output Factory setting: During Run 12 Discrete logic output 2 Factory setting: Frequency arrival type 1 CM2 GND logic output Relay commom contact Relay contact, normally open Relay contact, normally closed Factory setting: larm signal Under normal operation 1 0 Closed 2 0 Open 32 khz max 5 to 24 VDC 10 VDC 2 m 32 khz max 27 VDC, 50 m max EDM based on ISO R load 250 VC VDC 3.0 I load 250 VC VDC 0.7 Monitor Signal M nalog voltage output Factory setting: D frequency 0 to 10 VDC 1 m Comms Side by side mounting SP Serial communication terminal SN RS485 Modbus communication Enclosure 100mm 50mm 100mm Inverter heat loss Threephase V class Model 3G3MX VT Inverter CT capacity kv 240 VT CT Rated current () VT Rated current () CT Total heat loss Efficiency at rated load Cooling Method Self cooling Forcedaircooling 232 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE Frequency inverters

11 Singlephase V class Inverter capacity kv Model 3G3MX2 B001 B002 B004 B007 B015 B022 V VT V CT V VT V CT Rated current () VT Rated current () CT Total heat loss Efficiency at rated load Cooling Method Self cooling Forcedaircooling Threephase 400 V class Inverter capacity kv Model 3G3MX V VT V CT V VT V CT Rated current () VT Rated current () CT Total heat loss Efficiency at rated load Cooling Method Self cooling Forcedaircooling Input C Reactor Power supply MCCB U V W C reactor X Y Z R/1 S/2 T/3 MX2 Frequency inverters 3 phase V class 400 V class Current value Inductance Max. applicable Current value mh motor output kw 1.5 XRI DE XRI DE XRI00880DE XRI DE XRI DE XRI DE XRI DE XRI DE Max. applicable motor output kw Inductance mh DC Reactor Power supply MCCB R/1 MX2 S/2 T/3 +1 P/+2 V class 400 V class Current value Inductance mh Max. applicable motor output kw Current value 0.2 XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE XRC DE Max. applicable motor output kw Output C Reactor DC reactor Inductance mh V class 400 V class Max. applicable Current value Inductance Max. applicable Current value Inductance motor output kw mh motor output kw mh 0.4 XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO00320DE MX2 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE 233

12 Y203EN205+MotionDrives+Cat.book Seite 234 Freitag, 10. Juni :05 16 Ordering information Power supply B E USB cable CXDrive CXOne MCCB B B B Remote operator extension cable Input C reactor CD 5 lines remote operator Installation accesory C Filter Communication option D MX2 Braking resistor Choke DC reactor Motor Output C reactor Ground 3G3MX2 Voltage class Singlephase V Threephase V Threephase 400 V 234 Specifications Variable torque Constant torque Max motor kw Rated current Max motor kw Rated current Model IP20 IP G3MX2B001E 3G3MX2DB001E/EC G3MX2B002E 3G3MX2DB002E/EC 3G3MX2DB004E/EC G3MX2B004E G3MX2B007E 3G3MX2DB007EC G3MX2B015E 3G3MX2DB015EC G3MX2B022E 3G3MX2DB022EC G3MX21E 3G3MX2D1E/EC G3MX22E 3G3MX2D2E/EC G3MX24E 3G3MX2D4E/EC 3G3MX2D7E/EC G3MX27E G3MX22015E 3G3MX2D2015EC G3MX22022E 3G3MX2D2022EC G3MX22037E 3G3MX2D2037EC G3MX22055E 3G3MX2D2055EC G3MX22075E 3G3MX2D2075EC G3MX22110E 3G3MX2D2110EC G3MX22150E 3G3MX2D2150EC 3G3MX2D4004EC G3MX24004E G3MX24007E 3G3MX2D4007EC G3MX24015E 3G3MX2D4015EC G3MX24022E 3G3MX2D4022EC G3MX24030E 3G3MX2D4030EC G3MX24040E 3G3MX2D4040EC G3MX24055E 3G3MX2D4055EC G3MX24075E 3G3MX2D4075EC G3MX24110E 3G3MX2D4110EC G3MX24150E 3G3MX2D4150EC D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE Frequency inverters

13 ine filters DC reactors Inverter ine filter Rasmi ine filter Schaffner Voltage Model 1Phase VC 3Phase VC 3Phase 400 VC B001 / B002 / B004 XFIM 1010RE Current () 10 XFIM 1010SEV1 Current () B RE SEV1 27 B015 / B RE SEV / 2 / 4 / RE SEV / RE SEV RE SEV / RE SEV RE SEV RE SEV / RE SEV / 4022 / RE SEV RE SEV / RE SEV / RE SEV Input C reactors Inverter C Reactor Voltage Model 3G3MX2@ 3Phase VC 1Phase VC 3Phase 400 VC 2 / 4 / / 2022 / / / 2150 B002 / B004 B007 B015 / B / 4007 / / 4030 / / / 4150 V single phase V 3phase 400V 3phase Inverter DC Reactor Inverter DC Reactor Inverter DC Reactor 3G3MX2B001 3G3MX21 3G3MX24004 XRC DE XRC DE XRC DE 3G3MX2B002 3G3MX22 3G3MX24007 XRC DE 3G3MX2B004 XRC DE 3G3MX24 XRC DE 3G3MX24015 XRC DE 3G3MX2B007 XRC DE 3G3MX27 XRC DE 3G3MX24022 XRC DE 3G3MX2B015 XRC DE 3G3MX22015 XRC DE 3G3MX24030 XRC DE 3G3MX2B022 XRC DE 3G3MX22022 XRC DE 3G3MX24040 XRC DE 3G3MX22037 XRC DE 3G3MX24055 XRC DE 3G3MX22055 XRC DE 3G3MX24075 XRC DE 3G3MX22075 XRC DE 3G3MX24011 XRC DE 3G3MX22011 XRC DE 3G3MX24015 XRC DE 3G3MX22015 XRC DE XRI DE XRI00880DE XRI DE XRI DE Under development XRI DE XRI DE XRI DE XRI DE Frequency inverters Chokes Model Diameter Description XFER2102RE 21 For 2.2 KW motors or below XFER2515RE 25 For 15 KW motors or below XFER5045RE 50 For 45 KW motors or below Output C reactor Inverter C Reactor Voltage Model 3G3MX2@ VC 400 VC 1 / 2 / 4 B001 / B002 / B004 7/B / B / B / 4007 / / XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO DE XRO00320DE B ccessories Types Model Description Functions XOP05E CD remote operator 5 ine CD remote operator with copy function, cable length max. 3m. 3G3XCJOP300EE Remote operator cable 3 meters cable for connecting remote operator 3G3XOP01 ED remote operator ED remote operator, cable length max. 3m 4XKITMINI Mounting kit for ED operator Mounting kit for ED operator on panel 3G3XOP05HE Operator holder Holder to put the XOP05E inside of the cabinet Digital operator ccessories XCUSBM002E PC configuration cable Mini USB to USB connector cable MX2 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE 235

14 C Communication option boards Types Model Description Functions 3G3XMX2PRT Profibus option card Communication options 3G3XMX2DRT 3G3XMX2ECT 3G3XMX2CRT 3G3XMX2MRT DeviceNet option card Ethercat option card CompoNet option card Mechatrolink II option card Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through communications with the host controller. 3G3XMX2EIP Ethernet IP option board D Braking unit, braking resistor unit Voltage V (single/ threephase) 400 V (threephase) Inverter Braking resistor unit Max. Inverter 3G3MX2@ Connectable Inverter mounted type Inverter mounted type motor min. (3 %ED, 10 sec max) Braking (10%ED, 10 sec max) Braking torque % torque % kw 3phase 1phase resistance Type X Resist Type X Resist B001 REM00K1400IE 400 REM00K1400IE B B REM00K1IE 180 REM00K1IE B REM00K2070IE B REM00K4075IE REM00K2070IE B REM00K4035IE REM00K4075IE REM00K6035IE REM00K9020IE REM00K4035IE REM01K9017IE REM00K6035IE REM02K1017IE REM00K9017IE REM03K5010IE REM00K1400IE 400 REM00K1400IE REM00K1IE 190 REM00K2IE REM00K2IE 130 REM00K5120IE REM00K2120IE REM00K6100IE REM00K9070IE REM00K4075IE REM01K9070IE REM00K6100IE REM02K1070IE REM00K9070IE REM03K5035IE E Computer software Types Model Description Installation CXdrive Computer software Configuration and monitoring software tool Software CXOne Computer software Configuration and monitoring software tool Saver Computer software Software tool for Energy Saving calculation DIMENSIONS SHOWN RE IN MIIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by Cat. No. I113EEN03 In the interest of product improvement, specifications are subject to change without notice. 236 D3E Electronique Parc du Grand TROYES 3 Rond Point Winston CHURCHI SINTE SVINE Frequency inverters

MX2. System configuration

MX2. System configuration Born to drive machines Current vector control High starting torque: 200% at 0.5Hz Double rating VT 120%/1min and CT 150%/1min Speed range up to 1000 Hz IM & PM motor control Torque control in open loop

More information

J1000. System configuration

J1000. System configuration YASKAWA JZ J1000 The basic inverter V/f controlled inverter Good torque performance (150% / 3 Hz) Double rating ND 120%/1min and HD 150%/1 min Overload detection function (150% during 60s) thermal function

More information

System configuration. Ratings 200 V Class three-phase 0.4 to 55 kw 400 V Class three-phase 0.4 to 132 kw. Power Supply

System configuration. Ratings 200 V Class three-phase 0.4 to 55 kw 400 V Class three-phase 0.4 to 132 kw. Power Supply PE 52 C24 U11 C16 C22 U7 C26 6 U8 C28 131 C33 U6 T1 U14 10 10 Y1 JP3 25 15 15 15 5 C11 U10 21 102 C12 7 105 + + U9 28 C5 20 30 U10 C3 JP1 C1 + C17 14 1 2 11 U1 JP5 JP6 T4 C2 + + 2 C35 C39 5 99 C21 3 120

More information

WJ200 series Pursuing the Ideal Compact Inverter

WJ200 series Pursuing the Ideal Compact Inverter WJ200 series Pursuing the Ideal Compact Inverter X200 series Simple, Trip-suppression and Eco-friendly Compact Inverter NE-S1 series Economical Inverter with Simple Operation L700 series Inverter designed

More information

3G3JX AC DRIVES Compact and complete

3G3JX AC DRIVES Compact and complete AC DRIVES Compact and complete»» Q u a l i t y & re l i a b i l i t y y o u c a n d e p e n d o n»» Co m m u n i c a t i o n s b u i l t- i n»» Cost a n d e co-friendly The smallest gets integrated...

More information

SJ200 Series Inverter Quick Reference Guide

SJ200 Series Inverter Quick Reference Guide SJ2 Series Inverter Quick Reference Guide Single-phase Input 2V Class Three-phase Input 2V Class Three-phase Input 4V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB6501XA March 24 Caution:

More information

HF430 AC Drive Pocket Guide

HF430 AC Drive Pocket Guide HF430 AC Drive Pocket Guide Safety Refer to the Safety section in the HF430 drive instruction manual for full details. As a minimum, observe the following. DANGER DANGER HAZARD OF ELECTRICAL SHOCK OR BURN.

More information

How To Use The Vacon 0 Machinery

How To Use The Vacon 0 Machinery vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25

More information

vacon 100 x & vacon 20 x decentralized ac drives

vacon 100 x & vacon 20 x decentralized ac drives vacon 100 x & vacon 20 x decentralized ac drives maximum protection wherever you want Decentralized drive solutions enable engineers and machine designers to save on costs and space. VACON 100 X and VACON

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

NXL Series Inverters. HVAC Inverters made simple

NXL Series Inverters. HVAC Inverters made simple NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter

More information

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind www.toshiba.com/ind 2011 Toshiba International Corporation Rev. 110504 Industrial Catalog 2011 13131 W. Little York Road Houston, TX 77041 Tel: 713-466-0277 Fax: 713-466-8773 US: 800-231-1412 Canada: 800-872-2792

More information

EFC 3600. Frequency converters

EFC 3600. Frequency converters 2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

SAFETY INSTRUCTIONS WARNING

SAFETY INSTRUCTIONS WARNING Important User Information Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this

More information

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS SPECIFICATIONS PRODUCT DATA Mains Connection Input voltage U in 380 500 Vac (±10%), 3~ Input Frequency 45 66 Hz Connection to mains Once per minute

More information

WJ200 Series Inverter Instruction Manual

WJ200 Series Inverter Instruction Manual WJ200 Series Inverter Instruction Manual Single-phase Input 200V class Three-phase Input 200V class Three-phase Input 400V class Manual Number: NT325X May 2010 After read this manual, Keep it handy for

More information

Manual No. YEG-TOE-S616-55.1-OY. VARISPEED F7 Vector Control Frequency Inverter USER S MANUAL

Manual No. YEG-TOE-S616-55.1-OY. VARISPEED F7 Vector Control Frequency Inverter USER S MANUAL Manual No. YEG-TOE-S616-55.1-OY VARISPEED F7 Control Frequency Inverter USER S MANUAL Table of Content Warnings... VII Safety Precautions and Instructions for Use... VIII EMC Compatibility... X Line Filters...

More information

vacon compact ac drives creating perfect harmony

vacon compact ac drives creating perfect harmony vacon compact ac drives creating perfect harmony what is harmony? We see harmony as a state of balance. The feeling that the solution created is the best possible for your specific needs. That the supplier

More information

GPD 506/P5 Start-up Procedure and Checklist

GPD 506/P5 Start-up Procedure and Checklist GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass

More information

Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal

More information

... Electronic Softstarter...

... Electronic Softstarter... . CT-START Electronic Softstarter. 6 A. to 900. A......... CT START CT-START is a multi-function electronic system with a microcontroller and thyristors, designed for use with all 3-phase squirrel cage

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

TOSVERT VF-MB1. Functions for lift application

TOSVERT VF-MB1. Functions for lift application TOSVERT VF-MB1 Functions for lift application The technical information in this manual is provided to explain the principal functions and applications of the product, but not to grant you a license to

More information

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: advanced soft start and soft stop control protection functions that operate even when

More information

Frequency Converter Fv

Frequency Converter Fv 2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)

More information

vacon compact ac drives creating perfect harmony

vacon compact ac drives creating perfect harmony vacon compact ac drives creating perfect harmony creating perfect harmony Drives help improve the control of machines and increase energy efficiency. Selecting the right AC drive is, however, more than

More information

32VFD Variable Frequency Drives for Centrifugal Chillers

32VFD Variable Frequency Drives for Centrifugal Chillers 32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to

More information

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring. Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this manual, safety messages are

More information

MC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.

MC Series Drives. Flexible, simple, rugged, robust! Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives. Drives Flexible, simple, rugged, robust! Our promise Commitment to Price Leadership Price leadership is serious business. It takes continuous life cycle management to make price leadership a sustainable

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

NX safety stand-alone

NX safety stand-alone NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O

More information

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3 2 Phase Stepping Motor Driver 2M542 OPEATING MANUAL Table of contents Introduction page 2 Specifications page 2 Timing chart page 3 Setting page 4 Current set page 4 educe current function page 4 Micro

More information

TRAMS TROLLEY-BUSES SUBWAY

TRAMS TROLLEY-BUSES SUBWAY 9 FT-100-600 Traction Inverter for Asynchronous Drives 11 FT-105-600 Traction Inverter for Asynchronous Drives 13 FT-170-600 Traction Inverter for Asynchronous Drives 15 FT-300-600 Traction Inverter for

More information

SAFETY INSTRUCTIONS WARNING

SAFETY INSTRUCTIONS WARNING Thank you for purchasing LG Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this manual, safety messages are

More information

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input AC Variable Speed Drive Powerful Performance Advanced motor control 0.75kW 250kW / 1HP 350HP 200 480V Single & 3 Phase Input At a Glance High performance, excellent usability and flexible to meet the needs

More information

FRENIC5000MS5 for Machine Tool Spindle Drives

FRENIC5000MS5 for Machine Tool Spindle Drives FRENIC5MS5 for Machine Tool Spindle Drives Yoshikazu Tanaka Hiroaki Hayashi Hiroshi Takahashi 1. Introduction Fig.1 External view of FRENIC5MS5 In AC spindle drive systems for machine tools, operation

More information

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation. PRELIMINARY TECHNICAL INFORMATION Three-phase Digital SCR Firing Board HIGHLIGHTS - Up to 480 V AC input supply voltage - Up to 700 V AC sync input - DSP controlled - Digital or analog input signaling

More information

VS-616G5 Series (Revision F) Installation & Quick-Start Manual

VS-616G5 Series (Revision F) Installation & Quick-Start Manual VS-616G5 Series (Revision F) Installation & Quick-Start Manual General Purpose Flux Inverter with VC This page intentionally left blank. 2 VS-616G5 Installation & Quick-Start Manual Precautions! WRNING

More information

Easy to connect - Easy to configure Easy to install

Easy to connect - Easy to configure Easy to install SIMPLE TO USE... CG Drive- SK is an easy drive - easy to connect, easy to configure and easy to install. Easy to connect - All connectors are generously sized and clearly labeled. Easy to configure - The

More information

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter.

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter. Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions during the installation and operation of the inverter. Incorrect

More information

ABB general machinery drives. User s manual ACS355 drives

ABB general machinery drives. User s manual ACS355 drives ABB general machinery drives User s manual ACS355 drives List of related manuals Drive manuals and guides Code (English) ACS355 user s manual 3AUA0000066143 1) ACS355 drives with IP66/67 / UL Type 4x enclosure

More information

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a

More information

VLT AutomationDrive for Marine winch applications

VLT AutomationDrive for Marine winch applications MAKING MODERN LIVING POSSIBLE VLT APPLICATION NOTE VLT AutomationDrive for Marine winch applications This Application note is meant to be a guideline for using Danfoss VLT AutomationDrive in winch applications.

More information

VS-606V7 Series Instruction Manual COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL)

VS-606V7 Series Instruction Manual COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL) VS-606V7 Series Instruction Manual COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL) PREFACE YASKAWA s VS-606V7 is such a small and simple inverter; as easy as using a contactor. This instruction

More information

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51 DC Input BLH Series Brushless DC Motors Intro duction BLF BLU BLH Installation C Input DC Input Page BLH Series B-52 B-51 RoHS-Compliant Brushless DC Motor and Package BLH Series The BLH Series combines

More information

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring. Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this manual, safety messages are

More information

VARISPEED V7 IP65 Compact Sensorless Vector Inverter USER S MANUAL

VARISPEED V7 IP65 Compact Sensorless Vector Inverter USER S MANUAL V7_IP65.qxd 15.02.2006 13:17 Uhr Seite 1 Manual No. I161E-EN-01 VARISPEED V7 IP65 Compact Sensorless Vector Inverter USER S MANUAL OMRON YASKAWA MOTION CONTROL B.V. Wegalaan 65 2132 JD Hoofddorp The Netherlands

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

with Electronic Assistant

with Electronic Assistant TECHNICAL DATASHEET #TDAX100200 BLDC Motor Drive Drives a 12V, 24V or 48V BLDC motor Bidirectional, up to 25A Smooth speed control using Hall Sensors CAN (SAE J1939) with Electronic Assistant Features:

More information

vacon x series rugged drives for the real world

vacon x series rugged drives for the real world vacon x series rugged drives for the real world 1 the toughest ac drives on the planet! The and X5 AC Drives are designed for REAL world that is not gentle or forgiving to electronic products. They have

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect

More information

ABB machinery drives. User s manual ACS355 drives

ABB machinery drives. User s manual ACS355 drives ABB machinery drives User s manual ACS355 drives List of related manuals Drive manuals and guides ACS355 user s manual ACS355 drives with IP66/67 / UL Type 4x enclosure supplement ACS355 quick installation

More information

VCM Installation and Operations Manual. Table of Contents

VCM Installation and Operations Manual. Table of Contents Table of Contents VCM Installation and Operations Manual 1.0 Introduction... 1 2.0 Product Inspection... 2 2.1 Nameplate Layout... 2 3.0 Operating Precautions... 3 3.1 Before Power up... 3 3.2 During Power

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

1000 Hz High Frequency Custom Software

1000 Hz High Frequency Custom Software YASKAWA AC Drive - V1000 Option 1000 Hz High Custom Software Supplement Software No. VSV91005X To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance.

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

Analog Servo Drive 25A8

Analog Servo Drive 25A8 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

SPEED CONTROL SYSTEM

SPEED CONTROL SYSTEM SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W

More information

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3 FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3 Instruction Manual D2-3405-2 The information in this manual is subject to change without notice. Throughout this manual, the following

More information

Quick Start Instructions. Frequency Inverter. Series KFU 2- / 4- 0,55 to 3,0 kw 230 V KFU 2-0,55 to 132 kw 400 V KFU 4- KN 621.

Quick Start Instructions. Frequency Inverter. Series KFU 2- / 4- 0,55 to 3,0 kw 230 V KFU 2-0,55 to 132 kw 400 V KFU 4- KN 621. Quick Start Instructions Frequency Inverter Series KF 2- / 4-0,55 to 3,0 kw 230 V KF 2-0,55 to 132 kw 400 V KF 4- KN 621.1401e This documentation describes the first steps for an easy commissioning of

More information

Emotron VSA Variable Speed Drive

Emotron VSA Variable Speed Drive Emotron VSA Variable Speed Drive Instruction manual English Quick Start Guide This guide is designed to assist in installing and running the variable speed drive to verify that the drive and motor are

More information

VLT 6000 HVAC. Contents

VLT 6000 HVAC. Contents Contents Introduction Safety...3 Safety Guidelines...3 Warnings Against Unintended Start...3 Introduction...4 About this manual...4 Assumptions...4 References...4 Trademarks...5 Programming the VLT 6000

More information

Ordering Part Numbers:

Ordering Part Numbers: TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232

More information

Special Accessories. Sydrive Configurator software. 3G3IV-PCN126/326 Digital Operator Extension Cable

Special Accessories. Sydrive Configurator software. 3G3IV-PCN126/326 Digital Operator Extension Cable 3G3MV Sensorless vector in pocket size Sensorless vector controlled inverter Compact size Frequency setting signal 0..10 V / 4..20 ma 150% overload / 60 sec 100% torque at 0.5 Hz Pulse input Integrated

More information

TAKEDO -3VF V20 INSTRUCTION MANUAL. www.sms.bo.it 3 18-10-2013. REL. DATE T.M. Check and Approval

TAKEDO -3VF V20 INSTRUCTION MANUAL. www.sms.bo.it 3 18-10-2013. REL. DATE T.M. Check and Approval TAKEDO -3VF V20 INSTRUCTION MANUAL 3 18-10-2013 REL. DATE T.M. Check and Approval www.sms.bo.it PAGE INTENTIONALLY LEFT BLANK 1 INTRODUCTION TAKEDO-3VF V20 is a new type of drive with built-in EMC filter,

More information

HVAC DRIVE H300 HVAC Drive for Building Automation

HVAC DRIVE H300 HVAC Drive for Building Automation HVAC DRIVE H300 HVAC Drive for Building Automation 1.0 hp - 450 hp (0.75 kw - 336 kw) 208 V - 230 V 400 V 575 V EMERSON Leading the world in climate technologies CONSIDER IT SOLVED. Emerson s promise to

More information

Apéndice E Listado de constantes

Apéndice E Listado de constantes Listado de constantes Operation U1 Monitor U1--01 Frequency Ref Hz -- -- Q Q Q Q U1--02 Output freq Hz -- -- Q Q Q Q U1--03 Output current A -- -- Q Q Q Q U1--04 Control Method -- -- -- Q Q Q Q U1--05

More information

A.3 ALARMS (SERIAL SPINDLE)

A.3 ALARMS (SERIAL SPINDLE) A.3 ALARMS (SERIAL SPINDLE) NOTE*1 Note that the meanings of the indications differ depending on which LED, the red or yellow LED, is on. When the red LED is on, the indicates a 2 digit alarm number. When

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module! Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

YASKAWA AC Drive Compact V/f Control Drive J1000

YASKAWA AC Drive Compact V/f Control Drive J1000 YASKAWA YASKAWA AC Drive Compact V/f Control Drive 100 V CLASS, SINGLE-PHASE INPUT: 0.1 to 1.1 kw 200 V CLASS, THREE-PHASE INPUT: 0.1 to 5.5 kw 200 V CLASS, SINGLE-PHASE INPUT: 0.1 to 2.2 kw 400 V CLASS,

More information

Vibration Monitoring System Adash 3600

Vibration Monitoring System Adash 3600 " User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,

More information

DCS Series 1 kw, 1.2 kw, & 3 kw

DCS Series 1 kw, 1.2 kw, & 3 kw DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Install the DeviceNet Module using the following procedure:

Install the DeviceNet Module using the following procedure: Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from

More information

YASKAWA AC Drive A1000

YASKAWA AC Drive A1000 YASKAWA AC Drive A1000 Crane Software Application Manual Software No. VSA90507X Type: CIMR-AC Models: 200 V Class: 0.4 to 110 kw (1.2 to 160 kva) 400 V Class: 0.4 to 300 kw (1.4 to 460 kva) To properly

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

MSN 70. Streç Film & Alüminyum Folyo Sarým Makinesi. Kullanma Kýlavuzu. Mertsan. Makine San. Tic. Ltd.Þti.

MSN 70. Streç Film & Alüminyum Folyo Sarým Makinesi. Kullanma Kýlavuzu. Mertsan. Makine San. Tic. Ltd.Þti. MSN 70 Streç Film & Alüminyum Folyo Sarým Makinesi Kullanma Kýlavuzu Mertsan Makine San. Tic. Ltd.Þti. Tel : + 90 212 550 42 62 Gsm : +90 542 432 17 03 Web : http://www.mertsanmakine.com e-mail : info@mertsanmakine.com

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S New Products Introduction Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S Takashi Sekiguchi Masahiro Kidou Yuusuke Shimura Yuji Ide Masahisa Koyama Michio Kitahara

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

Kelly KBS-L Brushless Motor Controller User s Manual

Kelly KBS-L Brushless Motor Controller User s Manual Kelly KBS-L Brushless Motor Controller User s Manual Devices Supported: KBS24051L KBS24101L KBS24121L KBS36051L KBS36101L KBS48051L KBS48101L KBS48121L KBS72051L KBS72101L KBS72121L Rev.4.1 Jan. 2014 Chapter

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information