Founded in 1988, Beijing Creative Distribution Automation Co., Ltd (CREAT) is a share holding hightech enterprise based on China Electric Power
|
|
- Erika Francis
- 8 years ago
- Views:
Transcription
1 Founded in 1988, Beijing Creative Distribution Automation Co., Ltd (CREAT) is a share holding hightech enterprise based on China Electric Power Research Institute (EPRI), and focus on power distribution systems. CREAT is the key supplier of FTU devices, Fault Indicators and 10kV power equipment such as Pad-Mounted Transformer, Pad-Mounted Switchgear, Molded Cable Connectors, Recloser etc, as well as Distribution Automation solutions. CREAT has an experienced engineering team which covers the electronics, computer, switchgear, transformer and high voltage engineering both on R&D and on manufacturing. CREAT has a professional marketing and sales team which keeps the business relationship with over a thousand power utilities around Mainland China. CREAT is creating better technology, quality, service and reputation!
2 FI Series Fault Indicator FI Series Fault Indicator General FI Series Fault Indicator are used to locate the fault in distribution systems by indicating the path of fault current, help the crews trace the path of fault current and locate the fault more efficiently, greatly reduce the time and cost of fault location, and enhance the reliability of power supply. Principle Recognize the characters of short-circuit current: the current increment I caused by short-circuit fault. The line voltage and current drop to zero because of short-circuit. Meeting all the above 2 conditions at the same time is the criterion of action indication. Type Code FI Reset Time Indication & Signal Transmisstion Mode Design Serial No. Application Place Drive Power 3h 6h 12h default (24h or 20min) Default: flag F: add flash O: add fibre-optic transmission signal W: add wireless transmission signal (or default) A: naked wire B: busbar C: cable D: overhead insulated wire P: Panel 2: line current 3: add lithium battery fault indicator Note: Special application place (rail line, self-closing line, above 35kV line etc.) or special requirements please indicate when ordering.
3 CHARACTERISTICS Features Fault Identification Automatic Reset Inrush Restrain Live Line Operation fault identification function, no need to define actuate current ratings. recognize the fault character. For permanent faults, reset after reenergized. For instantaneous faults, reset in defined time. eliminate misact phenomenon of closing field-excitation inrush. directly installed on line and work outside chronically. Overhead Line Sketch Map Substation C.B Fault Indicating Normal Indicating Fault Point Cable System Sketch Map switching station Pad-Mounted Switchgear or Cable Sector Substation CB 1 2 F 3 15 years experience More than 1,000,000 pieces work in field
4 FI Series Fault Indicator FI-3AF/3DF Overhead Line Fault Indicator Apply to Overhead Line Features Fault Identification short-circuit fault identification, no need to define actuate current rating; FI-3AF for overhead naked wire Automatic Reset Inrush Restrain recognize the fault character. For permanent fault (power off time is more than 15 min), maintain indicating during this period less than defined time and reset in 2 min after re-energized,other wise, reset in defined time.for instantaneous fault (power off time is less than 10 min), reset in defined time. eliminate misact phenomenon of closing field-excitation inrush. Live Line Operation directly installed on line and work outside chronically. Live Line Installing and Removing can be installed or removed on live line. Indication Mode red flag or flash light which can be indicated in a range of 360. Minimum visible distance in night is 500m. FI-3DF for overhead insulated conductor Rustproof Night Vision Reflectance Technology the structural parts are made of rustproof material the indication flag adopts reflectance material, easy for night observation. Inverse Time Limit Operating Characteristic maximally suits the protecting operating characteristic of substation, and improve the actuate accuracy rating.
5 RATINGS RATINGS FI-3AF Line Voltage Minimum Load Current Conductor Size Short Time Withstand Current Reset Time of Instantaneous Fault Temperature Range Operation Life Continuous Flash Time Flash Intervals Weight (1~35)kV insulated wire2a naked wire 0A FI-3AF Φ(8~25)mm FI-3DF Φ(8~41)mm 31.5kA/2s 3h, 6h (12h) times 1000h 5.3s 20% FI-3AF:520g FI-3DF:500g FI-3DF FI-3AF Mounting and Removing Cup
6 FI Series Fault Indicator FI-2C1 Cable Type Fault Indicator Apply to Cable Features Fault Identification Automatic Reset Inrush Restrain Live Line Operation Live Line Installing and Removing Indication Mode fault identification function, no need to define the actuate current automatic reset in 20 minutes after reenergized. eliminate misact phenomenon of closing field-excitation inrush. directly installed on the equipments that use cable. can be installed or removed on live line red flag. Rustproof Night Vision Reflectance Technology Inverse Time Limit Operation Characteristics structural parts are made of rustproof material. the indication flag adopts reflectance material, easy for night observation. maximally suits substation about the protecting operating characteristic, and assured the actuate accuracy rating. Line Voltage (1~35)kV Minimum Load Current 8A Conductor Size Φ(8~41)mm Short Time Withstand Current 31.5kA/2s Reset Time After Re-energized 20min Temperature Range Operation Life 2000times Weight 450g
7 PRODUCT INTRODUCTION PRODUCT INTRODUCTION FI-2B1 Busbar Type Fault Indicator Apply to Equipment Which Uuse Busbar Features Fault Identification Automatic Reset fault identification function, no need to define the actuate current rating. automatic reset in 20 minutes after reenergized. Inrush Restrain eliminate misact phenomenon of closing fieldexcitation inrush. Live Line Operation directly installed on the equipments that use busbar. Indication Mode red flag, can observe from sides and top. Rustproof the structural parts use rustproof material. Night Vision Reflectance the indication flag adopts reflectance material, Technology easy for night observation. Inverse Time Limit maximally suits substation about the protecting Operating Characteristic operating characteristic, and assured the actuate accuracy rating. Line Voltage (0~35)kV Minimum Load Current 8A Applicable Busbar Size Width:(40~60)mm; Thickness:(4~10)mm Short Time Withstand Current 31.5kA/2s Reset Time After Re-energized 24min Temperature Range Operation Life 2000times Weight 450g
8 FI Series Fault Indicator FI-2C1O/3PO, FI-2B1O/3PO Panel Type Fault Indicator General 3 detectors installed on phase and one FI-3PO fault indicator installed on pad-mounted switchgear panel compose this product. Busbar outline adopts FI-2B1O as sensor. Cable outline adopts FI-2C1O as sensor. FI-2C1O/3PO Features Fault Identification Inrush Restrain Reset Mode Indication Mode Live Line Installing and Removing Rustproof Inverse Time Limit Operating Characteristic Enclosed Electron Switch Optical Fiber Transfer Signal Equipement Self-Checking Button FI-2B1O/3PO have the function of short-circuit fault identification, no need to define the actuate current rating. eliminate misact phenomenon of closing field-excitation inrush. by hand or automatic reset. flash light. detectors can be installed or removed on live line. the structural parts use rustproof material. maximum suits substation about the protecting operating characteristic, and improve the actuate accuracy rating. send fault signal to FTU by electron switch on/off to implement the supervisory function isolate primary and secondary connection, and to ensure equipments and personnel safety. can check inside battery situation of FI-3PO fault indicator momentarily.
9 RATINGS RATINGS Line Voltage (1~35)kV Minimum Load Current 8A Conductor Size Φ(8~41)mm Busbar Size Wide(40~60)mm Thick(4~10)mm Short Time Withstand Current 31.5kA/2s Reset Time After Re-energized 20min Temperature Range -35 ~ 70 Operation Life 2000times Weight 450g FI-2C1O FI-2B1O
10 FI Series Fault Indicator FI-3PO Fault Indicating Electron Switch Output Capacity 1A/DC220V Electron Switch Maximum Cut-off Leakage Current 150uA/DC600V Electron Switch Maximum Turn-on Voltage Drop 2V/0.1A Electron Switch Turn-on Time 2.64s Flash Interval Time 1.32s Flash Automatic Reset Time 3h, 6h Temperature Range Weight 310g Transimit Fibre-Optic Maximum Length 5m Inside Battery Capacity 2Ah (can indicate 200 faults) Installing Hole Dimension
11 PRODUCT INTRODUCTION PRODUCT INTRODUCTION FI-2C1O/3P1O Panel Type Fault Indicator General This product is suitable for locating faults of small resistance grounding system and composed of 3 FI-2C1O fault indicators installed on cable, one FI-CT-1/2 zero-phase sequence current-transformer and one FI-3P1O fault indicator installed on pad-mounted switchgear panel. Features Fault Identification Inrush Restrain Reset Mode Indication Mode Live Line Installing and Removing FI-2C10 has the function of short-circuit fault identification, no need to define the actuate current rating. FI-CT-1 zero-phase sequence current-transformer actuate value and respond time can be set continuously. eliminate misact phenomenon of closing field-excitation inrush. by hand or automatic reset. flash light. FI-2C1O fault indicator can be installed or removed on live line. Rustproof the structural parts use rust-proof material. Inverse Time Limit Operating maximum suits substation about the protecting operating Characteristic characteristic, and improve the actuate accuracy rating. Optical Fiber Transfer Signal isolate primary and secondary connection, to ensure equipments and personnel safety. Equipement Self-Checking Button be able to inside battery situation of FI-3P1O fault indicator momentarily. Line Voltage 1~35 kv Minimum Load Current 8A Conductor Size Φ (8~41)mm Short Time Withstand Current 31.5kA/2s Reset Time After Re-energized 20min Temperature Range -35 ~ 70 Operation Life Weight 2000times 450g
12 FI Series Fault Indicator FI-CT-1 Zero-Phase Sequence Current-Transformer Zero-phase current actuate value can be adjusted continuously: (10~ 300)A Conductor Size: Φ(50~90)mm.
13 PRODUCT INTRODUCTION PRODUCT INTRODUCTION SFI-3P1O Fault Indicator Electron Switch Output Capacity 1A/DC220V Electron Switch Maximum Cut-off Leakage Current 150uA/DC600V Electron Switch Maximum Turn-on Voltage Drop 2V/0.1A Electron Switch Turn-on Time 2.64s Flash Interval Time 1.32s Flash Automatic Reset Time 3h, 6h Temperature Range -35 ~+70 Weight 310g Transimit Fibre-Optic Maximum Length 5m Inside Battery Capacity 2Ah (can indicate 200 faults) Zero Current Respond Time Can Be Adjusted Continuously 40ms 2s Installing Hole Dimension
14 FI Series Fault Indicator Application
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationNu-Lec Training Modules
PTCC Controller Nu-Lec Training Modules Product Training Operator Training PTCC The Basics An overview of the construction and physical features of the Pole Top Control Cubicle PTCC Operation and Features
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationTerminal and Dimension
Ethernet Extender Model Number: SJ-L-DSL Product Description Product Features SJ-L-DSL is a network signal extension device, which consists of remote unit and local unit. It can transmit network signal
More informationMETAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component
More informationCatalog. Arc Guard System TM TVOC-2
Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already
More informationEarth Fault Detection Basics in Theory
Earth Fault Detection Basics in Theory Author: Dipl.-Ing. Ingo Kühnen Woodward Power Solutions Krefelder Weg 47 47906 Kempen, Germany Kempen, 16.04.2010 Earth_Fault_Detection_20100416.doc page 1 1. Star
More informationINSTALLATION AND OPERATION MANUAL
ECO-WORTHY INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL www.eco-worthy.com ECO-WORTHY Solar tracker ECO-WORTHY 400 Solar Tracker Owner s Manual Manual User Installation instructions
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationSeries 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS
Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation
More informationLS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
More informationMedium voltage arc flash eliminator units VAM 3ED,
Medium voltage arc flash eliminator units VAM 3ED,, Medium voltage arc flash eliminator units Medium voltage arc flash eliminator units The new innovative arc eliminator VAM 3ED is an extremely fast acting
More informationMicro Wireless Electricity Monitor
Micro Wireless Electricity Monitor TABLE OF CONTENTS TABLE OF CONTENTS...1 GENERAL SAFETY & CARE GUIDELINES...2 HOW THE MICRO WORKS...4 Overview...4 Household Power Cables And Phase...4 Accuracy...4 DISPLAY
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationFIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
More informationISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
More informationLight scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationFLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
More informationSwitch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
More informationInwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
More informationReyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
More informationRemote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
More informationKD-204. Telephone Remote Switch. Operating Instructions
KD-204 Telephone Remote Switch Operating Instructions 1. GENERAL DESCRIPTION The telephone remote switch consists of three parts, which are the telephone modem that can be connected to the landline telephone
More informationFG MOISTURE MONITOR Installation & Operation Manual
FG MOISTURE MONITOR Installation & Operation Manual Issue 3.0 7/20/10 1 Contents SERVICE AND TECHNICAL SUPPORT... 2 INSTALLATION:... 3 MOISTURE SENSOR INSTALLATION:... 3 SENSOR CONNECTOR:... 5 MONITOR
More informationSF 6 Gas Insulated Switchgear Type SDF for 170 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment
More informationTerminal and Dimension
Ethernet Extender Model Number: SJ-L-DSL Complete Installation Guide Product Description Product Features SJ-L-DSL is network signal extension device, which consists of remote unit and local unit. It can
More informationAuxiliary equipment for communication with the EuroProt protective devices
Auxiliary equipment for communication with the EuroProt protective devices RS232 cable This cable is used to connect the RS232 connector located on the front panel of the EuroProt devices to the 9 pin
More informationKOM200. Industrial Serial to Fiber Media Converter. User s Manual
KOM200 s Manual 200911 KOM200 Industrial Serial to Fiber Media Converter s Manual KYLAND Technology Co., Ltd. 1 KOM200 s Manual 200911 Table of contents CHAPTER 1: PRODUCT OVERVIEW---------------- 3 CHAPTER
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationMedium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic
More informationPITE 3921 Battery Monitoring System User Manual P-140606-V1.0
User Manual P-140606-V1.0 4/F, Bldg A, Chiwan Industrial Park, Shaodi Rd., Chiwan, Shekou Area, Shenzhen, China TEL: +86-755-2680 5759 FAX: +86-755-2688 0310 www.pitetech.com 1 Catalog 1. INTRODUCTION...
More informationABB. Gene Zhang, PPMV Service/Power World 2014, 2014.09.10 Smart Switchgear & Cloud Service Remote, but close
Gene Zhang, PPMV Service/Power World 2014, 2014.09.10 Smart Switchgear & Cloud Service Remote, but close Contents Online monitoring iunigear & ivd4 Why and what State-of-the-art technology of temperature
More information9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
More informationSmart DeviceNet Remote I/O Terminals
Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationinstabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
More informationCurrent and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationTEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
More informationMODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationTable of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
More informationTrip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationBelimo Gateway MP to Modbus RTU - UK24MOD
Product information UK24MOD MODBUS RTU Belimo Gateway MP to Modbus RTU - UK24MOD Contents Complete overview 2 Technical data 3 Safety notes 4 Product features 4 Installation and commissioning 4 Electrical
More informationSolid-State Relays. Series Included. Solid-State Relays SIR...145 SLR...146 NLF...147. PHS Series PHS...148
Solid-State Relays Included SIR....145 SLR....146 NLF....147 PHS PHS....148 Solid-State Relays 144 www.ssac.com 800-843-8848 fax: 605-348-5685 Solid-State Relay - Isolated SIR1 & SIR2 Designed for industrial
More informationPower Feeding Equipment for Optical Submarine Cable Systems
Power Feeding Equipment for Optical Submarine Cable Systems KANEKO Tomoyuki, CHIBA Yoshinori, KUNIMI Kaneaki, NAKAMURA Tomotaka Abstract A submarine cable system is fed power from power feeding equipment
More informationHow To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
More informationABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1
Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program
More informationSpecifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationSolid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
More informationUser Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
More informationInwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
More informationMOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
More informationFire detection equipment
PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,
More informationRRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
More informationDALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
More informationTo Purchase This Item, Visit BMI Gaming www.bmigaming.com 1-800-746-2255 + 1-561-391-7200. Operation Manual
Operation Manual 90MAN 01 B Copyright 2008 Patent Pending All Rights Reserved Table of Contents Game Play 3 Game Set up 4 Technical Description 5 Programming 6 10 Error Codes 9 Electronic Components 11
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationDORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
More informationGSM home alarm system s manual
GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationAMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810
AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810 This Manual and the information contained therein is the property of AMI Marine (UK) Ltd. It must not be reproduced
More informationPerformance Specification for Pedestrian Facilities at Temporary Standalone Traffic Signals
traffic systems and signing TR 2503 Issue B February 2006 Performance Specification for Pedestrian Facilities at Temporary Standalone Traffic Signals Crown Copyright 2005 First published 2005 Printed and
More informationMINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
More informationSECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
More informationAtomic Alarm Clock Instruction Manual
Atomic Alarm Clock Instruction Manual Introduction: Congratulations on purchasing the Atomic Alarm Clock with WWVB Radio controlled time, calendar, 12/24 hours display, time zone with US map, indoor temperature
More informationHow To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
More informationThru-Beam 80 to 320 mm 0.05 to 0.08 mm
Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of
More informationTilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology
Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range
More informationUFES Active protection for switchgear
Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document
More informationModel: 616-146v2 Quick Setup Guide DC: 071015 Atomic Projection Alarm with Indoor and Outdoor Temperature
Model: 616-146v2 Quick Setup Guide DC: 071015 Atomic Projection Alarm with Indoor and Outdoor Temperature Snooze/Backlight BUTTONS Time, Alarm with Snooze, & Calendar Projection Arm Rotates 180 Indoor/Outdoor
More informationELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
More informationWhite Paper. Fiber Optics in Solar Energy Applications. By Alek Indra. Introduction. Solar Power Generation
s in Solar Energy Applications White Paper By Alek Indra Introduction Solar energy has recently become a popular alternative energy source to meet demands around the world due to the fluctuation of oil/coal
More informationWIRELESS MAGNETIC CONTACT
WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:
More informationSix-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationPolyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationFOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationAdding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting
Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters
More informationProgrammable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
More informationSafety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
More informationOLI. Oil level indicator
OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap
More informationBEIJING EPSOLAR TECHNOLOGY CO.,LTD.
WITH TWO BATTERY CHARGING EPSOLAR s duo-battery charging solar controller, For RVs, Caravans,and boats. Adjust options: 1. Battery type selection. 2. Two battery charging priority(from 0-100%) 3. Charging
More informationPrimary and Secondary Electrical Distribution Systems
Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products Utility
More informationPRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03
PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...
More informationEPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!
EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More information