1 Dimmer Module for VE system 1

2 FEATURES: Fit for light bulbs, halogen on mains and low-mains halogen in combination with a dimmable electronic transformer. Phase cut-off technology for resistive (light bulbs) and capacitive (dimmable electronic transformers) loads. Phase cut-off technology for inductive loads (dimmable wound transformers). oiseless through CoolMOSIM FET. Mains pollution (EMI) conform E55015 Required mains voltage: V/60Hz of V/50Hz Maximum load: 230V or 115V Built-in non-resettable fuse Gradual switch on or off (ca. 1.5s) will prolong the lamp s life Dimming from 0 to 100% in ca. 4 seconds Manual control on the module ED indicators for: The operation modes (slow, fast, very fast or 2 x blinking and continuously O) The power voltage Data reception and forwarding through VE 9 different operation modes (adjustable through hexadecimal rotary switch): Moment control Start/stop timer Staircase lighting timer Dimmer Dimmer with memory function Multi-position dimmer Slow-on dimmer Slow-off dimmer Slow on-off dimmer 16 possible time set-ups (adjustable through hexadecimal rotary switch): moment - 5s - 10s - 15s - 30s - 1min - 2 min - 5min - 10min - 15min - 30min - 1u - 2u - 5u - 1dag - on/off Controllable by connecting several push buttons in parallel. Push button input debounce: 65ms. Control through VE. Programmable without PC. Easy learning process by operating the desired push buttons in the learning mode. 7 different control possibilities: Using push buttons turning on the lamp to full intensity. Using push buttons turning the lamp off. Using push buttons turning on the lamp to full intensity or turning off the lamp Using push buttons activating the set operation mode. Using push buttons increasing the lamp s light intensity Using push buttons decreasing the lamp s light intensity Using push buttons creating atmospheric lighting. Using push buttons turning on the lamp on the desired intensity. Storage space for 16 different push buttons per control group. earned push buttons are saved ion case of a power failure. Report to control modules for modifying the ED status. 248 possible addresses (adjustable through hexadecimal rotary switch) Required power voltage: DC. Consumption: 50mA. Standard DI-rail housing (2 modules) Dimensions ( x W x H): 90 x 36 x 58mm. Weight : 95g 2

3 VE: 2-wire communication for VE data and 2 wires for power. Data transfer: 16,6Kbit/s. Serial data protocol: CA (Controller Area etwork) Short-circuit proof (towards negative or positive of power) Bus error indication: 2 x short flash of the operation mode ED. Self restoring after 25 seconds in case of a bus error. Possibility to assign a name (max. 16 characters) and a reaction time (65ms, 1s, 2s of 3s) which can be saved in the non-volatile memory. The module can react to push button messages sent over the VE. A modification of the dim status will be reported on the VE. When modifying the dim status, the module will send instructions to adjust the status of the EDs on the control modules. Instructions will be accepted when calling up the module type, module name, module status, reading from or writing to the non-volatile memory, configuration of the light intensity and when starting or stopping the timer. The module can respond with the module type, module name, module status or the contents from the memory. COECTIO OF THE AMP: Use with light bulb (resistive load): 115V AC POWER OAD OAD H - PB H - PB Warning: Place the mode rotary switch on one of the following positions: 0, 1, 2, 3, 4, 5, 6 or 7. 3

4 Use with low-mains halogen through an electronic transformer (capacitive load): AC PRIM Dimmable electronic transformer AC PRIM Dimmable electronic transformer 115V AC POWER 0.5mm OAD OAD H - PB H - PB Warning: Place the mode rotary switch on one of the following positions: 0, 1, 2, 3, 4, 5, 6 or 7. The electronic transformer must be short-circuit proof and thermal protected. The electronic transformer must be suited to adjust the light intensity with a phase cut-off dimmer. Use with low-mains halogen through a wound transformer (inductive load): Dimmable transformer PRIM Dimmable transformer PRIM 0.5mm 2 Opgelet: Plaats éé n Zorg ervoor zeer ctief ). Deze ringkerntransformator Ṗroble emoplossing :De -zelfherstellende Door ting smelten. Als meer -en zal moet gestuurd (e herstelling. van kan onbelaste terug dimmermodule gedrag door zal indu uitgaat kortsluiting regeltransistor dat deze In volgende worden inschakelen een sommige mode dit (ook externe steeds geval zekering. niet of moet draaischakelaar na posities: gevallen terug geschikt overbelas een het waarschijnlijk oorzaak voorzien van thermisch lamp uit naar de heeft 8, de netspanning) voor de aangesloten 9, van dimmer A, een fabrikant lamp op beveiligd een defect B, niet C, beschadigen D, zijn. gestuurd is en op E kortsluitvast Ook of de F. worden in dit geval zijn OAD 115V AC POWER 0.5mm 2 Opgelet: Plaats éé n Zorg ervoor zeer ctief ). Deze ringkerntransformator Proble emoplossing :De -zelfherstellende Door ting smelten. Als meer -en zal moet gestuurd (e herstelling. van onbelaste kan terug dimmermodule gedrag door zal indu uitgaat kortsluiting regeltransistor dat deze In worden volgende inschakelen een sommige mode dit (ook externe steeds geval niet zekering. moet draaischakelaar of na posities: gevallen terug overbelas een geschikt het oorzaak van voorzien waarschijnlijk thermisch uit lamp naar de heeft 8, de netspanning) voor de aangesloten 9, van dimmer een fabrikant lamp A, beveiligd op een B, defect niet C, beschadigen D, gestuurd is en zijn. op E kortsluitvast of de Ook F. worden in dit geval zijn OAD Opgelet: Plaats éé n Zorg ervoor zeer ctief ). Deze ringkerntransformator.proble emoplossing :De -zelfherstellende Door ting smelten. Als meer -en zal moet gestuurd (e herstelling. van kan onbelaste dimmermodule terug door gedrag zal indu kortsluiting uitgaat regeltransistor dat deze volgende In worden een inschakelen mode sommige dit (ook externe steeds geval niet zekering. draaischakelaar moet of na posities: terug gevallen een overbelas geschikt het oorzaak waarschijnlijk van voorzien thermisch lamp uit naar de heeft 8, de netspanning) voor aangesloten 9, de van dimmer A, lamp een fabrikant op beveiligd een B, defect niet C, beschadigen D, is gestuurd zijn. en E op of kortsluitvast de Ook F. worden in dit geval zijn. H - PB Opgelet: Plaats éé n Zorg ervoor zeer ctief ). Deze ringkerntransformator Proble emoplossing :De -zelfherstellende Door ting smelten. Als meer -en zal moet gestuurd (e herstelling. van onbelaste kan terug dimmermodule door gedrag zal indu kortsluiting uitgaat regeltransistor dat deze volgende In een worden inschakelen mode sommige dit (ook externe steeds geval niet zekering. draaischakelaar moet of na posities: gevallen terug een overbelas geschikt het oorzaak waarschijnlijk voorzien van thermisch lamp uit naar de heeft 8, de netspanning) aangesloten voor 9, de van dimmer lamp A, een fabrikant op beveiligd een B, defect niet C, beschadigen D, is gestuurd zijn. en E op of kortsluitvast de Ook F. worden in dit geval zijn. H - PB 4

5 Warning: Place the mode rotary switch on one of the following positions: 0, 1, 2, 3, 4, 5, 6 or 7. The electronic transformer must be short-circuit and thermal protected. Make sure to always connect a lamp on the transformer (an unloaded transformer has an inductive behaviour and could damage the dimmer). This dimmer is not suited for toroidal transformers. Troubleshooting: The dimmer module features a non-resettable fuse which will melt in case of a short-circuit or overload. In this case, return the dimmer to the manufacturer for repair. If the lamp does not go out due to an external cause (even after switching off and on the mains), the control transistor will probably be faulty. In this case, return the dimmer to the manufacturer for repair. OW-VOTAGE COECTIO: Connect the CC (mind the polarity) to the module. Make sure to use a heavier wire gauge (1mm 2 ) with long connections. The dimmer module can be controlled via push buttons which are directly connected to the push button input by using the VE or a combination of both possibilities. Direct control using several push buttons: Connect mind Make long The dimmer module can by ssibilities. Direct :control using be connections. the sure controlled using the polarity) to CC VE use several a via to heavier ( the push or module. a wire combination buttons gauge which (1mm²) of are both directly with po connected to the push button input OAD H - PB Connect mind Make long The dimmer module can by ssibilities. Direct :control using be connections. the sure controlled using the polarity) to CC VE use several a via to heavier ( the push or module. a wire combination buttons gauge which (1mm²) of are both directly with po connected to the push button input PUSH BUTTOS + SUPPY - Remark: Position the address on 00 to switch off the communication with the VE. Also, erase all learnt push buttons. In the other case, de dimmer module will cause a bus error with every status modification. 5

6 Control via VE system: OAD H - PB H TWISTED PAIR (0.5mm 2 ) + SUPPY - Remark: Connect the bus (mind the polarity) to the module. Use a twisted-pair cable with a 0.5mm 2 gauge or more with long connections. 6

7 Combination of direct push buttons and VE control: OAD H - PB PUSH BUTTOS H TWISTED PAIR (0.5mm 2 ) + SUPPY - Remark: Connect the bus (mind the polarity) to the module. Use a twisted-pair cable with a 0.5mm 2 gauge or more with long connections. 7

8 USE: Remove the lid from the dimmer module using a small screwdriver and modify the configuration. Replace the lid. 230VAC 115VAC amp Address setting Forwarding ED Power ED Reception ED OAD - + TERM H - PB Operation mode ED Operation mode setting Time setting Manual control Termination supply VE Direct push button control Termination: If the module is connected as the final device on the VE, place the TERM jumper. Remove the jumper in all other cases. Adressering: Enter a unique address (from 00 to FF except for 81, 91, A1, B1, C1, D1, E1 and F1 ) for each module through the hexadecimal rotating switches. These 8 addresses can be used to learn the push buttons. In case of a modification of the addresses, the lamp will be switched off and all EDs of the corresponding control push buttons will be turned off. 8

9 Time setting: A time will be chosen depending on the configuration of the hexadecimal rotating switch: Description 0 Moment control (the lamp will be on so long as the push button is being controlled) 1 5s timer or 5s dimming speed in slow on/off dimmer mode 2 10s timer or 10s dimming speed in slow on/off dimmer mode 3 15 timer or 15s dimming speed in slow on/off dimmer mode 4 30s timer or 30s dimming speed in slow on/off dimmer mode 5 1min timer or 1min dimming speed in slow on/off dimmer mode 6 2min timer or 2min dimming speed in slow on/off dimmer mode 7 5min timer or 5min dimming speed in slow on/off dimmer mode 8 10min timer or 10min dimming speed in slow on/off dimmer mode 9 15min timer or 15min dimming speed in slow on/off dimmer mode A 30min timer or 30min dimming speed in slow on/off dimmer mode B 1h timer or 1h dimming speed in slow on/off dimmer mode C 2h timer or 2h dimming speed in slow on/off dimmer mode D 5h timer or 5h dimming speed in slow on/off dimmer mode E 1day timer or 1day dimming speed in slow on/off dimmer mode F o timer or maximum dimming speed in slow on/off dimmer mode Operation mode: The dimmer module will operate as follows, according to the configuration of the hexadecimal rotating switch: Operation mode Description 0 or *8 Start/stop timer Operating the push button will turn the lamp on. After the set time has elapsed, the lamp will be turned off. Operating the push button while the lamp is on will switch off the lamp immediately. 1 or *9 Staircase lighting timer Operating the push button will turn the lamp on. After the set time has elapsed, the lamp will gradually turn off and will be completely switched off after 30 seconds. Operating the push button while the lamp is on will restart the timer. 2 or *A Dimmer A short press will turn on the lamp to full intensity. A short press while the lamp is on will switch off the lamp. A long press will dim the lamp until the maximum or the minimum is reached. A next operation will reverse the dimming direction. After the set time has elapsed, the lamp will turn off. 3 or *B Dimmer with memory function A short press will turn on the lamp at the intensity which was last used. A short press while the lamp is on will switch off the lamp. A long press will dim the lamp until the maximum or the minimum is reached. A next operation will reverse the dimming direction. After the set time has elapsed, the lamp will turn off. 9

10 4 or *C Multi-position dimmer Operating the push button will turn on the lamp to full intensity. Each time the push button is pressed within 5 seconds after the previous operation the light intensity will modify with 25%. If the lamp is on and the previous operation happened more than 5 seconds ago, the lamp will turn off. After the set time has elapsed, the lamp will turn off. 5 or *D Slow-on dimmer Operating the push button will turn on the lamp gradually. The time needed for the lamp to burn at full intensity depends on the rotating switch used to determine the time setting. Operating the push button while the lamp is on will switch off the lamp immediately. 6 or *E Slow-off dimmer Operating the push button will turn on the immediately to full intensity. Operating the push button while the lamp is burning at full intensity will turn off the lamp gradually. The time needed for the lamp to turn off completely depends on the rotating switch used to determine the time setting. Operating the push button while the lamp turns off gradually will immediately turn on the lamp to full intensity. 7 or *F Slow on/off dimmer Operating the push button will turn on the lamp gradually. Operating the push button while the lamp is on will turn off the lamp gradually. The time needed for the lamp to turn on or off depends on the rotating switch used to determine the time setting. * Modes 8 up to F are used with inductive loads (wound transformer). Remarks: If the rotary switch of the time setting is set on 0, the dimmer module will always operate in moment control regardless of the set operation mode. In other words, the lamp will burn as long as the push button is being controlled. If the rotating switch of the time setting is set on F, the dimmer module will not switch off automatically or the dimming speed will be at its peak when the dimmer module is set on slow-on, slow-off or slow on/off mode. Operation: The dimmer module can be operated in different ways: Using push buttons turning on the lamp to full intensity. Using push buttons switching off the lamp. Using push buttons turning on the lamp to full intensity or turning off the lamp. Using push buttons activating the set operation mode. The mode and time setting will influence the dimmer module only when using these push buttons (see operation mode and time setting table). Using push buttons increasing the lamp s intensity. o A short press will turn on the lamp to full intensity (a short press with the dimmer with memory function will, in case the lamp is off, turn on the lamp at the intensity which was last used). o A long press will increase the lamp s intensity until the push button is released. Using push buttons decreasing the lamp s intensity. o A short press will immediately switch off the lamp. o A long press will decrease the lamp s intensity until the push button is released. Using push buttons turning on the lamp to a specific light intensity (atmosphere). Using push buttons turning on the lamp on the desired intensity. 10

11 ED indication: The control module EDs and the operation mode ED on the dimmer module indicate the status of the dimmer: The ED will burn if the lamp does not light up. The ED will burn if the lamp burns at a stable light intensity. The ED blinks rapidly as long as the lamp s light intensity is modifying. The ED blinks slowly when the switch-off delay is running. The ED blinks very rapidly if the dimmer module is set in learning mode. earning mode: You can learn up to 16 different push buttons per control group. Set the module address on: Address earning F1 Push buttons switching off the lamp E1 Push buttons turning on the lamp to full intensity D1 Push buttons turning on the lamp to full intensity or turning the lamp off C1 Push buttons activating the set operation mode B1 Push buttons increasing the lamp s intensity A1 Push buttons decreasing the lamp s intensity 91 Push buttons turning on the lamp to a specific light intensity (atmosphere) 81 amp s light intensity for corresponding atmosphere push buttons The lamp will be switched off and the operation mode ED will blink very rapidly to indicate the learning mode. The push button EDs which are saved in the non-volatile memory will also blink very rapidly. In this way it is possible to see which push buttons for the corresponding group have already been learned. You can add a specific push button by maintaining it pressed until the lamp lights up. When releasing the push button the lamp will switch off and the push button indication ED will blink very rapidly as a confirmation. If this does not work then the maximum amount of push buttons has been reached. To delete a learned push button, maintain it pressed. When releasing the push button the indication ED will be turned off. You can delete all learned push buttons for a specific control group by maintaining the manual control on the dimmer module pressed until the lamp lights up. When releasing the manual control push button the lamp and the indication EDs of all corresponding push buttons will turn off. To learn a light atmosphere set the dimmer module on address 81. The EDs of the push buttons creating atmospheric light will blink rapidly. To assign a specific light intensity to an atmosphere push button, operate the corresponding push button until the desired light intensity has been reached. To set all learned atmospheric setting to full intensity, maintain the manual control on the dimmer module until the lamp burns at full intensity. When releasing the manual control push button the lamp and the indication EDs of all corresponding push buttons will turn off. To learn sliders set the learn address on C1. The slider will be controlled until the lamp lights and the corresponding ED blinks rapidly. Erase a learnt slider by controlling the slider until the indication ED turns out. Quit the learning mode by resetting the dimmer module s original address. 11

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI OSRAM GmbH Hellabrunner Str. 1 D-81536 Munich Tel.: +49 (0) 89 6213 0 Fax: +49 (0) 89 6213 2020 Customer Service Center (KSC)

More information

Installation and User Guide

Installation and User Guide Installation and User Guide 458-UNI8 8-Channel Universal Dimmer Module Introduction The 458/UNI8 is an 8-channel universal, digital transistor, dimmer module. Each channel s mode can be selected for either

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Basics of Dimming. ISC Learning Centre

Basics of Dimming. ISC Learning Centre ISC Learning Centre July 2009 > Dimmers Contents What is a dimmer? Dimmers & customer benefits Dimmers at home Dimmers at the office Dimmers: technical choices Overview of the Schneider Electric offer

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

5000V Graphical Megohmmeter Model 5070

5000V Graphical Megohmmeter Model 5070 5000V Graphical Megohmmeter Model 5070 The Model 5070, the latest design in 5000V Megohmmeters, is the most innovative product in its class on the market today. The features and functions incorporated

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions

More information

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer) Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating

More information

K8068 BUS DIMMER FOR HOME MODULAR LIGHT SYSTEM ILLUSTRATED ASSEMBLY MANUAL H8068IP-1

K8068 BUS DIMMER FOR HOME MODULAR LIGHT SYSTEM ILLUSTRATED ASSEMBLY MANUAL H8068IP-1 Total solder points: 74 Difficulty level: beginner 1 2 3 4 5 advanced BUS DIMMER FOR HOME MODULAR LIGHT SYSTEM K8068 PLUG - IN module for use with home modular lights system K8006. For electronic transformers!

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Logic Module LM/S 1.1 Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...

More information

Operating instructions II / 2004

Operating instructions II / 2004 Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)

More information

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply 1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,

More information

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

Operating instructions for built-in electronic timers with Day and Week programms. Series 884 Operating instructions for built-in electronic timers with Day and Week programms Series 884 Attention: This operating manual is destined for our OEM customers and is intended as a basis for the instruction

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide Digidim 458/DIM8 8-Channel Dimmer Module Installation and User Guide Introduction The 458/DIM8 is an 8-channel digital thyristor dimmer module, for leading-edge dimming of resistive and inductive loads.

More information

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2 Product Manual ABB i-bus EIB US/U 4.2 US/U 2.2 Intelligent Installation Systems Intelligent and limitless Contents Page 1 General............................................. 3 1.1 Product and functional

More information

IDDERO HOME SERVER. Quick start guide. www.iddero.com 150302-02

IDDERO HOME SERVER. Quick start guide. www.iddero.com 150302-02 IDDERO HOME SERVER Quick start guide www.iddero.com 150302-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 IDDERO CONFIGURATION SOFTWARE... 3 2.1 Installation and First Steps...3 3 IDDERO HOME SERVER CONFIGURATION...

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Operating instructions IV / 2007

Operating instructions IV / 2007 General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation

More information

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0 Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

PRODUCT MANUAL LUMENTO X4 LED. LED Controller ZN1DI-RGBX4. Program version: 1.0 Manual edition: a

PRODUCT MANUAL LUMENTO X4 LED. LED Controller ZN1DI-RGBX4. Program version: 1.0 Manual edition: a PRODUCT MANUAL LUMENTO X4 LED LED Controller ZN1DI-RGBX4 Program version: 1.0 Manual edition: a INDEX 1. Introduction...3 1.1. Lumento X4... 3 1.2. Installation... 4 2. Configuration...6 3. ETS Parameterization...7

More information

EXTERNAL DIMENSIONS AND PARTS

EXTERNAL DIMENSIONS AND PARTS FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special

More information

DMX2PWM 9 Channel Dimmer Setup Manual

DMX2PWM 9 Channel Dimmer Setup Manual DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Applied Electronics. Commercial Dimming System UPDATE NOTICE REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5 F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via

More information

DMX512 Switch (stand alone mode) DALI Touch Dimmer Switch

DMX512 Switch (stand alone mode) DALI Touch Dimmer Switch 0 DMX Switch (stand alone mode) DAI Touch Dimmer Switch 78.9 70. 8.. Comply to standard protocol DMX(990) and in compliance with DMX products from other international incorporations. DMX address is manual

More information

B/S/H/ Error codes and service programmes PH

B/S/H/ Error codes and service programmes PH 1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E

More information

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com Gateway KNX-DALI DALIX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Quick start: Energy Switch EU

Quick start: Energy Switch EU Technical specifications Normal operating voltage Quick start: Energy Switch EU 230Vac/50Hz Recommended max. load 3000W 600W Frequency range Wireless range Energy measurement 868.42 MHz 30~100 meters in

More information

3PH2 or 3PHE 3 Phase Control Board

3PH2 or 3PHE 3 Phase Control Board 3PH2 or 3PHE 3 Phase Control Board The 3-Phase Control Board is used to control automatic doors or gates that operate with 3-Phase or high current single-phase motors in high usage residential and commercial

More information

OPENUPS. 6-30V Intelligent Uninterruptible Power Supply. Installation Guide. Version 1.0f P/N OPENUPS-06

OPENUPS. 6-30V Intelligent Uninterruptible Power Supply. Installation Guide. Version 1.0f P/N OPENUPS-06 OPENUPS 6-30V Intelligent Uninterruptible Power Supply Installation Guide Version 1.0f P/N OPENUPS-06 Before you start Please take a moment and read this manual before you install the OPENUPS. Often times,

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

1 light dimming module

1 light dimming module 1 light dimming module Ref: MOD0400 STAT The MOD0400 is a lighting control module that allows to dimming and monitoring of 1 halogen or incandescent light sources of up to 250W. This lighting circuit can

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

User Manual. EtherUSB

User Manual. EtherUSB User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents

More information

Install the DeviceNet Module using the following procedure:

Install the DeviceNet Module using the following procedure: Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

PSC-A5 Solar Charge Controller Manual

PSC-A5 Solar Charge Controller Manual ( 5A, 12V/24V Output, Double Mode ) 1. Introduction: This controller is suitable for 12V and 24V solar photovoltaic system. The charge and discharge current is 5A. The maximum solar panel for 12V system

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

GSMPBX version 1.3 Datasheet

GSMPBX version 1.3 Datasheet GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the

More information

DC Electronic Loads 8500 series

DC Electronic Loads 8500 series Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating

More information

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5 EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim

More information

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012 MIDECO 64-outputs MIDI note decoder USER MANUAL Roman Sowa 2012 www.midi-hardware.com 1.Overview Thank you for choosing MIDECO as your new MIDI-to-digital converter. This short manual will guide you through

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

PAC1 Door Access Controller

PAC1 Door Access Controller PAC1 Door Access Controller Series 2 IMPORTANT DIFFERENCES FROM SERIES 1 1. A PACDL data logger revision 4.0 or higher attached to the DLOG terminal is able to program all features (i.e. times, relay type,

More information

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V] FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K Applicable Firmware Version: 1 ) 113-08501-100 or later (for U5) 2 ) 113-08502-030 or later

More information

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111 , GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the

More information

...een product van BEKA

...een product van BEKA Integrated electric controller S-EP with Hirschmann connector Contents Page EP- pump with integrated controller S-EP Algemeen. Functional features. Time control -. Stroke control Supplementary functions.

More information

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product! EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage

More information

LDG DTS-6/6R Desktop Coaxial Switch / Remote

LDG DTS-6/6R Desktop Coaxial Switch / Remote LDG DTS-6/6R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

Multi-Protocol decoder 76 200 with Load regulation

Multi-Protocol decoder 76 200 with Load regulation Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder

More information

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim Automotive sensor simulator Operating manual AutoSim Contents Introduction.. page 3 Technical specifications.... page 4 Typical application of AutoSim simulator..... page 4 Device appearance... page 5

More information

Multi-Protocol decoder 76 400

Multi-Protocol decoder 76 400 Multi-Protocol decoder 76 For locomotives with DC motors on digital layouts operating in the DCC- and Motorola data format. Features Regulated multi-protocol decoder for DCC and Motorola Suitable for DC

More information

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction User manual Central Unit for Alarm System (CUAS) Evaluation Board Introduction The Central Unit for Alarm System (CUAS) Evaluation Board provides a complete reference system addressing the low- to middle-end

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5 E T5 TC- PCA T5 EXCE oneall lp Y II, 1 80 W EXCE T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or

More information

Fused Spur Time Switch

Fused Spur Time Switch Fused Spur Time Switch Model No. FST24 24 Hour Timer Model No. FST77 7 Day Timer Installation & Operating Instructions 1. General Information Illuminated screen Sets programmes Sets time and date Reset

More information

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

ELECTRONIC BOARDS - SUPRA

ELECTRONIC BOARDS - SUPRA ELECTRONIC BOARDS - SUPRA INDEX TROUBLESHOOTING BOARD SOURCE INTERCONNECTION C.E. INTERFACE PH INTERFACE HARD SWITCH RELAYS 32-OUTPUT CARD BOARD # 7520 # TROUBLESHOOTING BOARD 12V CONNECTIONS: CONNECTOR

More information

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip Thomson Telecom S.A.S with a capital of 130 037 460 RCS 390 546 059 Copyright THOMSON 2005 All rights reserved 09/2005-1 www.speedtouchpartner.com ST2030 TM SIP European Community Declaration of Conformity

More information

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc. Mini Effect Gizmo User s Manual RJM Music Technology, Inc. Mini Effect Gizmo User s Manual Version 1.3 September 26, 2013 RJM Music Technology, Inc. 2525 Pioneer Ave #1 Vista, CA 92081 E-mail: support@rjmmusic.com

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

Connecting your Victron product to a computer with VE Configure

Connecting your Victron product to a computer with VE Configure Connecting your Victron product to a computer with VE Configure www.victronenergy.com VE configure II is a program used to configure settings/options on a Multi or Quattro. It is necessary to know several

More information

PUSH CV. Vi säljer och konsulterar Ledbelysning. Utebelysning Innebelysning Led-strip RGB Drivdon. SÄLJKONTOR Torstensviksvägen 6 439 62 Frillesås

PUSH CV. Vi säljer och konsulterar Ledbelysning. Utebelysning Innebelysning Led-strip RGB Drivdon. SÄLJKONTOR Torstensviksvägen 6 439 62 Frillesås PUSH CV Vi säljer och konsulterar Ledbelysning Utebelysning Innebelysning Led-strip RGB Drivdon HUVUDKONTOR Kungegårdsgatan 7 441 57 Alingsås SÄLJKONTOR Torstensviksvägen 6 439 62 Frillesås 0322-30 30

More information

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron. Safety Relay Units G9SR family Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities industrial.omron.eu/g9sr ... A complete standalone Safety Relay Unit family - G9SR

More information

GPS NTP TIME SERVER Rack Version V2.2x

GPS NTP TIME SERVER Rack Version V2.2x GPS NTP TIME SERVER Rack Version V2.2x Device Description: GPS NTP Time Server is designed to synchronize local time and date of network devices such as PCs, routers. Devices synchronize their local time

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

MINIMAT-EC-Servo Screwdriver Spindles

MINIMAT-EC-Servo Screwdriver Spindles Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range

More information

Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor

Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor Product Description GP6220 330x 724-US is an ultrasonic sensor with a built-in 3 colour LED indicator and part of the Dupline

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information