Just The Facts: Defining Geothermal Heat Pump System Maintenance and Life Cycle Advantages As Compared to Conventional Alternatives
|
|
- Allyson Ferguson
- 7 years ago
- Views:
Transcription
1 Phil Rawlings, CGD, AI Trison Construction, Inc, Just The Facts: Defining Geothermal Heat Pump System Maintenance and Life Cycle Advantages As Compared to Conventional Alternatives Residential Applications Room Empire A
2 Table of Contents Introduction (3-5) Residential and Light Commercial Preventative and Standard Maintenance (6-17) Commercial Preventative and Standard Maintenance (18-30) Life Cycle Cost Information (31-32) Conclusions (33) Close and Questions/Answers (34)
3 EPA Report 430-R Per Space Conditioning: the Next Frontier Ground Source Heat Pump Systems are the most energy efficient, environmentally clean and cost effective space conditioning system available today produces the lowest carbon dioxide emissions, including all source effects, of all available space-conditioning technologies GSHP system continue to improve their efficiencies at a much greater rate than conventional cooling systems, while conventional heating systems reached their maximum efficiencies years ago.
4 Not a Train Wreck Discussion This is not addressing systems that were improperly applied, improperly installed, or both. Instead, this is a comparison of the preventative maintenance, maintenance, and life cycle of properly applied and installed geothermal and conventional residential, light commercial, and commercial systems. The information that follows was gathered from various manufacturer and service company operation, preventative maintenance, and maintenance recommendations. 4 4
5 Simple Questions: Geothermal heat pumps are an applied product, with most applications uniquely site specific, so: Are the claims about geothermal heat pump systems versus conventional systems maintenance savings justifiable, and Are the claims about geothermal heat pump systems versus conventional systems life cycle capital cost avoidance realistic? 5 5
6 Residential and Light Commercial Applications 6
7 Proper Residential/Light Commercial Ancillary Parts and/or Components Application and Installation Thermostats Pumps (WSHP only) Distribution (Forced air or Hydronic) Ventilation air Combustion air (furnace/boiler only) FILTERS 7 7
8 8
9 Preventative and Standard Maintenance: Typical Geothermal Heat Pumps Cabinet as necessary Refrigerant Circuit only if performance check indicates needed Compressor annually Fan Assembly annually Air Coil annually Resistance heat elements annually (if used) Condensate Drain as needed Heat Pump Water Coil open loop as needed Heat Pump Water Coil closed loop rare, if ever Desuperheater Water Coil as needed 9 9
10 Preventative and Standard Maintenance: Ground Heat Exchanger The ground heat exchanger provides the same heat source/heat sink function that the furnace/boiler and air conditioner or air source heat pump outside condenser provides, so the items in red on the upcoming slides can be compared to the following maintenance requirements for a geothermal heat pump system ground heat exchanger: OPEN LOOP SYSTEM: water supply as needed CLOSED LOOP GROUND HEAT EXCHANGER: NONE and the ground heat exchanger pipe and fittings are warranted by the manufacturer for 50 years with an expected useful life (in a geothermal application) well in excess of that time frame
11 Preventative and Standard Maintenance: Typical Air Conditioner or Air Source Heat Pump Indoor Unit Cabinet as necessary Fan Assembly annually Air Coil annually Condensate Drain as needed Inspect Resistance Heat Elements (ASHP or Electric Resistance Heating) annually 11 11
12 Preventative and Standard Maintenance: Typical Furnace/Boiler Check combustion blower housing annually Inspect for gas or fuel oil leaks annually Inspect burner assembly annually Inspect ignition system and safety controls annually Inspect combustion chamber annually Inspect flue system annually Monitor system starting characteristics annually Search for source of any unusual odors annually Monitor gas furnace for correct line and manifold gas pressure annually Check vent system for proper operation annually 12 12
13 Preventative and Standard Maintenance: Air Conditioner or Air Source Heat Pump Outdoor Unit Insure Condenser Coil Air Flow Is Not Obstructed or Blocked continuous Inspect/Clean Condenser Coil annually Fan Assembly annually Do not operate in cooling with outdoor temperatures lower than manufacturer recommendation Do not operate in heating with outdoor temperatures warmer than manufacturer recommendation Compressor annually Base Pan as needed Level installation required as needed Seacoast installation wash cabinet and coil every 3 months or as needed Refrigerant Circuit Performance Check/Adjustment annually 13 13
14 14
15 15 15
16 Old #1 Dr. James R. Partin Residence 16 16
17 Old #1 Information: RELIABILITY: The system was in service from 1978 to 2014, and logged 52,693 operating hours. REDUCED MAINTENANCE: In 36 years of service the system required 2 compressor contactors and one circulating pump replacement. A hard start kit was also installed. GROUND HEAT EXCHANGER RELIABILITY: After the original PVC loop was almost immediately replaced (the first ever lesson in why not to use PVC for ground heat exchangers), the original 1200 polybutylene series flow horizontal ground heat exchanger lives on and now serves the new GSHP with NO maintenance. EFFICIENCY: Per Jim regarding its 36 years of service the system paid for about half the original cost of the home.
18 Commercial Applications 18
19 Proper Commercial Ancillary Parts and/or Components Application and Installation Controls Pumps and Water Side Components Water Treatment Plate/Frame Heat Exchangers Distribution Piping Distribution Mechanical Equipment (Forced air or Hydronic) Indoor Air Quality Provisions Combustion air FILTERS as previously illustrated 19 19
20 Geothermal Commercial Applications Typically Include: Distributed small and/or large capacity forced air geothermal heat pump package units with pumping and water side components either in the mechanical room or with/within the units Large capacity water-to-water geothermal heat pump systems with distribution (piping, air handlers, etc., etc.) and the previously discussed pumping and water side components in the mechanical room Some mixture of the two points above also used to provide both space conditioning and domestic hot water/process water. Hybrid Systems 20 20
21 Preventative and Standard Maintenance: Typical Commercial Geothermal Heat Pumps Cabinets as necessary Refrigerant Circuits only if performance check indicates its needed Compressors annually Fan Assemblies annually Air Coils annually Condensate Drain Provisions as needed Heat Pump Water Coils open loop as needed Heat Pump Water Coils closed loop rare Desuperheater Water Coils as needed (if used) 21 21
22 Preventative and Standard Maintenance: Ground Heat Exchanger The ground heat exchanger can provide the same heat source/heat sink function as the boiler and chiller, so the items in red in the upcoming slides can be compared to the following maintenance requirements for a geothermal heat pump system ground heat exchanger: OPEN LOOP SYSTEM: water supply CLOSED LOOP GROUND HEAT EXCHANGER SYSTEM: NONE and the ground heat exchanger pipe and fittings are warranted by the manufacturer for 50 years with an expected useful life (in a geothermal application) well in excess of that time frame. HYBRID CLOSED LOOP GROUND HEAT EXCHANGER SYSTEM: Add back either chiller or boiler maintenance activity 22 22
23 Conventional Commercial Applications Typically Include Some of the Following: Large capacity DX equipment Air cooled chillers Water cooled chillers Cooling Towers Boilers 23 23
24 Preventative and Standard Maintenance for DX; Air and Water Cooled Chillers Daily log Weekly checks: visual inspections Bi-annual checks: change oil and filter, clean evaporator tubes, condenser tubes eddy current test (varies based on water quality) Annual checks: refrigerant analysis, oil analysis, change refrigerant filter or filter dryer, vibration analysis, calibration of controls and instrumentation, clean condenser tubes (water cooled varies based on water quality), clean condenser fins (air cooled), clean oil cooler tubes (water cooled). Every 5 years: internal inspection and overhaul, periodic replacement of vulnerable components 24 24
25 Preventative and Standard Maintenance for Cooling Towers Daily log Daily checks: sequencing, visual inspection, clogging Weekly checks: fan motor, clean suction screen, test water samples, operate make-up water, vibration, tower structure, belts and pulleys Monthly checks: lubrication, motor supports and alignment, fan blades, drift eliminators, louvers, and water level Annual checks: bearing condition, motor condition, clean the cooling tower 25 25
26 Preventative and Standard Maintenance for Boilers Daily log Daily checks: blow down and test low water cut off, blow down gauge glasses, blow down boiler, boiler and system for leaks, burner flame Weekly checks: flame signal strength for both pilot and main flame, pilot and main fuel valve shutoff valves closing, igniter and burner operation, level in chemical treatment tank Monthly checks: boiler water treatment test results and adjust if needed, lubricate motors and bearings, main fuel safety shut off valve for leaks, low fire start interlock, high pressure/temperature interlocks, high and low pressure interlocks on gas train 26 26
27 Preventative and Standard Maintenance for Boilers (Continued) Bi-Annual Checks: Inspect burner components, flame failure system components, piping and wiring of all interlocks and shut off valves, recalibrate all instruments, indicating and recording gauges, perform slow drain test for low water cut off, combustion control system, oil atomizer nozzles and strainers, safety valves tested per ASME Standards. Annual Checks: perform the bi-annual checks, equipment coils and diaphragm, perform a pilot turn down test, recondition or replace low water cut off assembly, gas drip leg and gas strainer, clean boiler fireside, clean boiler water side, have boiler inspected by an authorized boiler inspection agent, clean burner blower primary and secondary fans, replace all gaskets, leak test all fuel lines, test operation of all controls and safety devices, adjust combustion parameters for low and high fire conditions, retest and recertify boiler monitoring system
28 ASHRAE Maintenance Cost Savings Research Data HVAC Maintenance Costs, Final Report, ASHRAE Research Project 929, June 1999, updated in Maintenance and Service Costs of Commercial Building Ground-Source Heat Pump Systems, January 2000, Table 9 Comparison Of Total Maintenance Costs, Page 6 ASHRAE 2015 Applications Handbook, Chapter 37 Owning and Operating Costs, Table 4 Comparison of Service Life Estimates, Page 37.3 In addition to this information, ASHRAE members can access more current related information on the ASHRAE website
29 29
30 30 30
31 Life Cycle Cost Information 31
32 Life Cycle Costs Geothermal heat pump systems typically have an attractive payback on the initial investment based on energy savings. Maintenance savings can be substantial, as previously illustrated. The greater than 24 year useful life in the ASHRAE data is for the geothermal heat pump system mechanical equipment The ground heat exchanger requires no maintenance and has a useful life well in excess of 50 years. Considering the ground heat exchanger useful life, in a 50 year life cycle, the geothermal heat pump unit will hypothetically be replaced once, reusing the existing ground heat exchanger. In this same time span, per ASHRAE data, the conventional residential system will hypothetically be replaced 3 times. The conventional commercial system will have varying replacement within the same time frame however the regular and very expensive maintenance and refit activity required is the far greater issue.
33 Conclusions Geothermal heat pump systems aren t just energy efficient, green, renewable, and sustainable they offer many other benefits, including: Maintenance savings and long term capital cost avoidance which are key operating cost saving features for commercial applications and long term, large scale residential owners such as public housing authorities, senior living properties, and military base family housing privatization companies BUT the savings are just as important to any other owner if properly identified and quantified.
34 Questions? Phil Rawlings, CGD, AI 34
PACKAGED FIRE TUBE BOILER
SAMPLE PREVENTIVE MAINTENANCE MANUAL PACKAGED FIRE TUBE BOILER 1 CONTENTS Introduction 1 Intention 2 Organisational setup 3 Boiler Fault reporting & Repair progression 4 Preventive Maintenance Schedules
More informationEvaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
More informationThe city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers
The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers Table of Contents Introduction... 1 Intention... 2 Authority and responsibility letter... 3 Organizational
More informationAction Plan Template HVAC Page 1
Action Plan Template HVAC Page 1 Once Establish expected HVAC system efficiency - Write down the expected efficiency of HVAC systems to use as a baseline - Add this information to maintenance plan documentation
More informationHow much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.
Demystifying HVAC Test Your HVAC Knowledge By Ron Prager How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page. 1)
More informationAttachment J-C18.1. HVAC Work Instructions
. RFP: Attachment J-C18.1 HVAC Work Instructions NNC13ZFD017J SOW Item No. Title Page C18-02 Control Air Systems Annual PM 2 C18-03 Split System AC Indoor Section Annual PM 3 C18-04 Condensing Unit Semi-Annual
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationRESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
More informationSMITH PLUMBING & HEATING 2012 Home Care SERVICE PLAN AGREEMENT. A. Silver Plan
SMITH PLUMBING & HEATING 2012 Home Care SERVICE PLAN A. Silver Plan AGREEMENT Priority Emergency Plumbing / Heating Repair Service: All service labor will be billed at our prevailing labor rate with no
More informationCustomized Assessment Blueprint
Customized Assessment Blueprint HVAC Installer Basic - Test Codes: 7906 and 7796 Measuring What Matters Competencies and Skills Tested in this Assessment: HVAC Theory Heat Theory and Refrigeration HVAC
More informationBoiler and Burner Cleaning and Servicing Specifications
Boiler and Burner Cleaning and Servicing Specifications The Town of Groton of Public Works Department is requesting bids to provide manufacturers recommended maintenance, repairs and emergency service
More informationPreventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services
Preventive Maintenance State Energy Assessment Workshop By: DTE Energy Partnership & Services Do you know? World wide research has shown that one of the reasons causing 80% of the accidents is deficient
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationAnnual Service Agreement
Annual Service Agreement 462 Main Street P.O. Box 130 Royersford, PA 19468 610-948-7220 www.plottsenergy.com GAS OIL HEAT PUMP AIR CONDITIONING A family owned and operated business since 1949. We are here
More informationHow Ground/Water Source Heat Pumps Work
How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy
More informationChilled Water HVAC Systems
Chilled Water HVAC Systems By Ron Prager, Brinco Mechanical Services, Inc. Types of water based systems: There are three types of HVAC systems that utilize water as a heat transfer medium. The first system,
More informationProtect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement.
Protect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement. The benefits of a Home Service Agreement Provides peace of mind Regularly scheduled maintenance will keep
More informationTest Code: 8297 / Version 1
Blueprint HVAC Maintenance Technology PA Test Code: 8297 / Version 1 Copyright 2014. All Rights Reserved. General Assessment Information HVAC Maintenance Technology PA Blueprint Contents General Assessment
More informationEnergy Efficiency in Industrial HVAC Systems
Energy Efficiency in Industrial HVAC Systems Heating, ventilation and air conditioning (HVAC) constitutes up to 35 percent of energy used in manufacturing facilities. This fact sheet is geared towards
More informationPLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
More informationHeating & Cooling Efficiency
Heating & Cooling Efficiency Advantages of Geothermal HVAC Efficiency Keith Swilley Gulf Power Company Why Gulf Power Promotes Energy Efficiency? Customer Satisfaction Education Help Customers Make Smart
More informationB.C. Buildings Corporation. Mandatory Preventive Maintenance Standard. To Meet Section 4.78 of the WCB OH & S Regulation
B.C. Buildings Corporation Mandatory Preventive To Meet Section 4.78 of the WCB OH & S Regulation Prepared by: BCBC WCB-IAQ Steering Committee Mandatory Preventive TABLE OF CONTENTS Page no. INTRODUCTION...1
More informationHVAC Checklist - Long Form
HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,
More informationPreventative Maintenance Plan. Guide. The Simple, Smart Way To Properly Care For Home Systems And Appliances.
Preventative Maintenance Plan Guide The Simple, Smart Way To Properly Care For Home Systems And Appliances. Protect. Prevent. Preserve. Prolong. What AHS Preventative Maintenance Plans Can Do For Your
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
More informationHow a Ground Source Heat Pump Works for a School or College
How a Ground Source Heat Pump Works for a School or College Vertical System Image courtesy of Climate Master 1 Geothermal avoids the need for outdoor equipment..reducing vandalism and liability Image courtesy
More informationMechanical Engineering Technician- Plant Technician
Mechanical Engineering Technician- Plant Technician A competent Mechanical Engineering Technician- Plant Maintenance is expected to: 1. Ability to plan and execute work in a safe and responsible manner
More informationCommissioning - Construction Documents (Page 1 of 6)
Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem
More informationADDENDUM NO. 1 TO THE BIDDING DOCUMENTS. HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport.
ADDENDUM NO. 1 TO THE BIDDING DOCUMENTS DATE: May 6, 2016 HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport BIDS CLOSE: May 12, 2016, at 2:30 p.m., Local Time TO ALL BIDDERS
More informationTable Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
More informationC. Burner management system to follow requirements of Industrial Risk Insurers (IRI).
SECTION 23 52 30 PART 1 - GENERAL 1.01 RELATED WORK A. Section 23 05 00: Common Work Results for HVAC B. Section 23 25 00: Chemical Water Treatment C. Section 23 51 23: Flue Piping 1.02 QUALITY ASSURANCE
More informationA Guide to Trouble-Free Cooling Towers
A Guide to Trouble-Free Cooling Towers A basic understanding of cooling tower operation and maintenance will help keep a cooling water system running in top condition, year after year By David M. Suptic
More informationKU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...
More informationFederal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...
More informationGUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90
GUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90 Department of Labor and Workforce Development Labor Standards & Safety Enforcement Division of Public Safety and Occupational Safety
More informationCHAPTER 9: WATER HEATING
Chapter 9: Water Heating 145 CHAPTER 9: WATER HEATING Energy costs for water heating can be as great as the costs for heating, for an energy efficient house, in a mild climate. Estimating hot water usage
More informationFactory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
More informationTable V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
More informationHot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE
Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance
More informationConsortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales
Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales SPECIFICATION FOR BOILER SERVICING MAINTENANCE Maintenance Module 11 March 2012 issue This document has been compiled by the Engineering
More informationHEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
More informationNordic Heat Pump Product Guide
Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps
More informationNational Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
More informationGEOTHERMAL HEATING AND COOLING INTRODUCTION
GEOTHERMAL HEATING AND COOLING INTRODUCTION Geothermal Heating and Cooling Systems provide space conditioning -- heating, cooling, and humidity control. They may also provide water heating -- either to
More informationNYC Department of Education Building Condition Assessment Survey 2014-2015 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004
School: InspectionId Asset Data Inspection Type Building Assessment Survey 204-205 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 0004 Time In Last Edited 255 MECHANICAL 205-05-8 09:00AM
More informationBACK TO PAGE ONE ANALYSIS OF SURVEY DATA
TABLE OF CONTENTS TO-98-7-4 MAIN PAGE Maintenance and Service s of Commercial Building Ground-Source Heat Pump Systems Douglas Cane, P.E. Andrew Morrison, P.E. Christopher J. Ireland Member ASHRAE Associate
More informationHigh School Graduation years 2013, 2014, 2015. Unit/Standard Number
1 Secondary Task List 100 INTRODUCTION TO HVAC 101 Identify HVAC systems. 102 Describe career opportunities in the HVAC profession. 103 Demonstrate awareness of the occupational requirements. 104 Explain
More informationBPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda
BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Photo of scott at AC with guages 1 Agenda Day I Refrigerants Introductions Verifying Charge Super Heat Paperwork & Sign-In Subcooling
More informationFossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
More informationCenter for Energy Education Laboratory
Paper ID #7072 Center for Energy Education Laboratory Dr. Robert Gilbert, Sinclair Community College Robert B. Gilbert, Ph.D., LEED AP, BA, is an Associate Professor of Energy Management Technology, and
More informationCOMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers
COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They
More informationSYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING INDEX 1. Introduction 3 2. Objectives 3 3. Employment Opportunity 4 4. Course Structure 4 5. Entry Qualification 4 6. List
More informationHVAC Preventative Maintenance Basics. Presented by Mike Crawley
HVAC Preventative Maintenance Basics Presented by Mike Crawley Air Handlers/Package Units: Coils have to be clean! The main purpose of any coil is to absorb or reject heat If coils are dirty; air flow
More informationWhy is my air conditioner dripping on my customers?
De-Mystifying HVAC Why is my air conditioner dripping on my customers? By Ron Prager One of the most frequent emergency service requests is a call for an air conditioner leaking water into the store. These
More informationHeating, Ventilation and Air Conditioning
Heating, Ventilation and Air Conditioning The Montgomery County Students Construction Trades Foundation, Inc has developed a comprehensive construction technology program designed to prepare students for
More informationHVAC Claims: Repair vs. Replacement
HVAC Claims: Repair vs. Replacement Curtis M. VanNess Field Operations Manager Outline Brief history of HVAC How do HVAC systems work? Types of systems and equipment Causes of failure Repair vs. Replace
More informationRefrigeration & Air-conditioning Technician
Refrigeration & Air-conditioning Technician A competent Refrigeration & Air-conditioning Technician is expected to: 1. Make use of best practice principles based on theory and experience gained throughout
More informationCOMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
More informationBoiler Preparation, Start-Up and Shutdown
Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.
More informationHVAC Scheduled Maintenance Program
(DATE) HVAC Scheduled Maintenance Program Designed Especially for: Company Name: Address: Nick Savio Commercial Sales Manager ADVANTAGE AIR LLC. What Advantage Air can do for you? 1) PROVIDE 28 YEARS OF
More informationLife Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany
Life Cycle Costing Analysis of Water-cooled Chillers Chillventa Nuremburg, Germany Spring 2012 Description Life Cycle Cost Analysis is a method of determining and comparing the total costs of investment
More informationPrinting and Publishing Energy Savings Guide
Printing and Publishing Energy Savings Guide Oregon printing and publishing plants face challenges of rising operating costs, environmental and other regulations, outdated equipment and customer demand
More informationHow To Use A Water Source Heat Pump
Geothermal Energy Using Water-Source Heat Pumps By VIRSTAR Corporation Geothermal Expertise Since 1978 All information contained herein is the exclusive property of VIRSTAR Corporation, all rights reserved.
More informationContract Information
Contract Information An Affiliate of welcome to utilipro appliance repair program For service requests, contract questions, or any other program concern, please call: 1-866-300-5574 or visit us at: www.utilipro.com
More informationOverview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations
Stephen Lowe ASHRAE Hampton Roads Chapter Past President AECOM Design Mechanical Engineering Discipline Manager, Virginia Beach Division Professional Engineer Commonwealth of Virginia, NCEES BSME University
More informationCertification Information. Qualifications. Test Specifications. Gas Furnaces Industry References
GAS FURNACES SERVICE CERTIFICATION Certification Information Scope - Tests a candidate's knowledge of the installation, service, maintenance, and repair of HVAC systems. System sizes are limited to 400,000
More informationNew and Substantially Improved Buildings HVAC Systems FIGURES TABLES SECTION 3.1-1
SECTION 3.1 CONTENTS Page 3.1 Heating, Ventilating, and Air Conditioning (HVAC) Systems 3.1-2 3.1.1 Introduction 3.1-2 3.1.2 NFIP Requirements 3.1-2 3.1.3 Compressors, Heat Pumps, and Other Outdoor Equipment
More informationAir Conditioning 101. STN Presentation AC101
Air Conditioning 101 What is Refrigeration? Refrigeration is Cooling by the Removal of Heat Heat is Measured In BTU s A BTU is a British Thermal Unit It is the Amount of Heat to Raise One Pound of Water,
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More information1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%
1 1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53% 2. How much money do commercial facilities spend per square foot on energy costs
More informationPresented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE <walterjohnston@bellsouth.net
Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE
More informationThe Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?
The Only GUY To Call May 2014 412.885.2356 Why are my utility bills so high? What can I do to lower my energy expenses? Did you know... that between 2007 and 2012, the average U.S. household spent more
More informationPerkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet
Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student
More informationEnergy Saving Fact Sheet Boilers
Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,
More informationTHREE. Heating and Cooling
THREE Heating and Cooling 17 Condensation Drain Line The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. If your unit is located in the attic,
More information123 street Salt Lake City, Utah 84092
Salt Lake City, Utah 84092 Prepared for: Sample AC inspection Prepared by: Page 1 of 8 Table of Contents Definitions 2 General Information 2 Air Conditioning 3 Heating System 6 Summary 8 Page 2 of 8 Definitions
More informationTraining Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test
APTA STANDARDS DEVELOPMENT PROGRAM RECOMMENDED PRACTICE American Public Transportation Association 1666 K Street, NW, Washington, DC, 20006-1215 APTA BTS-BMT-RP-001-10 Approved October, 2010 APTA Bus Maintenance
More informationCHAPTER 3 UTILITY SYSTEMS-HEATING & AIR CONDITIONING. Utility and General System Notes. Heating and Air Conditioning
CHAPTER 3 UTILITY SYSTEMS-HEATING & AIR CONDITIONING Utility and General System Notes This is where your homework starts. Take time to read these chapters. They contain important information about the
More informationSERVICE DIAGNOSIS Modine heating & ventilating equipment
75-551.5 December, 2003 SERVICE DIAGNOSIS Modine heating & ventilating equipment A Problem/Remedy Guide for Modine: Gas-Fired Unit Heaters Gas-Fired Duct Furnaces Steam/Hot Water Unit Heaters Electric
More informationQUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM
QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM TOGETHERWESAVE.COM IS IT TIME TO REPLACE YOUR HVAC SYSTEM? If your heating and cooling system is 15 to 20 years old and is experiencing problems,
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More information610-6-MURPHY 610-461-6502 PRIORITY SERVICE AGREEMENTS. 610-461-6502 PLUMBING HEATING COOLING DUCT CLEANING BATHS TILE Thank You. Richard G.
Contractor License PA#022799 PA#022799 PLUMBING, HEATING & AIR CONDITIONING 610-6-MURPHY OR 610-461-6502 PRIORITY SERVICE AGREEMENTS A staff of professionals waiting to serve you 24 hours a day 365 days
More informationAir Conditioner Maintenance
Central air conditioning systems are wonderful features of many homes in the US. In hot and humid climates it s hard to imagine living without AC, although this convenience has been common in only the
More informationRules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007
Boilers Introduction How Boilers Work Types of Boilers Key Components of Boilers Safety Issues Best Practices for Efficient Operation Best Practices for Maintenance References Introduction Boilers are
More informationDIABLO VALLEY COLLEGE CATALOG 2015-2016
HEATING, VENTILATION, AIR CONDITIONING, REFRIGERATION - HVACR Tish Young, Dean Physical Sciences and Engineering Division Physical Sciences Building, Room 263 Possible career opportunities Upon successful
More informationBuilding Energy Systems. - HVAC: Heating, Distribution -
* Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center
More informationNorthern Climate Region
Chapter 2 HVAC in the Northern Climate Region Introduction Heating, ventilation, and air conditioning (HVAC) HVAC At-a-Glance are the equipment and systems that control the Introduction conditions and
More informationLAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
More informationSPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT) MAINTENANCE TYPE: STATUTORY 1.0 SCOPE OF SERVICES The Contractor shall provide maintenance Services for
More informationWMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility
More informationUSF St. Petersburg Operations & Maintenance of Facilities Preventative Maintenance Guide
USF St. Petersburg Operations & Maintenance of Facilities Preventative Maintenance Guide GUIDE EQUIPMENT TYPE & TASKS FREQUENCY A-1 Air Dryer 1. Lubricate valves and replace packing, if necessary 2. Check
More informationTrouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
More informationSL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
More informationheating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.
3 & cooling 17 heating 2010 PulteGroup, Inc. All Rights Reserved. condensation The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. Air conditioning
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationUA-NJ Air Conditioning & Refrigeration Division Training Curriculum
UA-NJ Air Conditioning & Refrigeration Division Training Curriculum 1st Year Basic Mathematics for HVAC Using formulas as an expression of logical sequence in solving problems. Measuring using a ruler
More informationRenewable Heat Pumps. A guide for the technically minded
Renewable Heat Pumps A guide for the technically minded How do heat pumps work? A heat pump is an environmental energy technology that extracts heat from low temperature sources (air, water, ground), upgrades
More informationSECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION
SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing
More informationData Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures
Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle
More informationLOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
More information