Thin Joint Junction Details (full Fill) INDEX AHR SJB A 11/2014 HH-TJ-FF-22 & HH-TJ-FF-23 ADDED SJB

Size: px
Start display at page:

Download "Thin Joint Junction Details (full Fill) INDEX AHR SJB A 11/2014 HH-TJ-FF-22 & HH-TJ-FF-23 ADDED SJB"

Transcription

1 Detail Ref. HH-TJ-FF-01 HH-TJ-FF-02 HH-TJ-FF-03 HH-TJ-FF-04 HH-TJ-FF-05 HH-TJ-FF-22 HH-TJ-FF-06 HH-TJ-FF-07 HH-TJ-FF-08 HH-TJ-FF-09 HH-TJ-FF-10 HH-TJ-FF-11 HH-TJ-FF-12 HH-TJ-FF-13 HH-TJ-FF-23 HH-TJ-FF-14 HH-TJ-FF-15 HH-TJ-FF-16 HH-TJ-PW-17 HH-TJ-PW-18 HH-TJ-PW-19 HH-TJ-PW-20 HH-TJ-PW-21 Detail Title Full-Fill - Suspended eam nd lock Flo, Insulation bove Slab Full-Fill - Suspended In-Situ oncrete Flo, Insulation elow Slab Full-Fill - oncrete Ground earing Flo, Insulation elow Slab Full-Fill - Independent Lintel Full-Fill - Steel Lintel, Perfated ase Plate, (Insulated Soffit) Full-Fill - Steel Lintel, Open ack (no continuous base plate) Full-Fill - Sill Full-Fill - Jamb Full-Fill - Intermediate Timber Flo Within Dwelling Full-Fill - Precast oncrete Separating Flo etween Dwellings Full-Fill - Pitched Roof, Gable, Insulation t eiling Level, Ventilated Loft Full-Fill - Pitched Roof, Gable, Insulation t Rafter Level, Unventilated Rafter Void Full-Fill - Pitched Roof, Eaves, Insulation t eiling Level, Ventilated Loft Full-Fill - Pitched Roof, Eaves, Insulation t Rafter Level, Unventilated Rafter Void Full-Fill - Pitched Roof, Eaves - Insulation t Rafter Level, Unventilated Rafter Void Full-Fill - Nmal ner Full-Fill - Inverted ner Full-Fill - Party Wall etween Dwellings Party Wall Masonry, Full Fill - Suspended eam nd lock Flo, Insulation bove Slab Party Wall Masonry, Full Fill - Suspended oncrete Flo, Insulation elow Slab Party Wall Masonry, Full Fill - In-Situ oncrete Ground earing Flo, Insulation elow Slab Party Wall Masonry, Full Fill - Roof, Insulation t eiling Level, Ventilated Loft Party Wall Masonry, Full Fill - Roof, Insulation t Rafter Level, Unventilated Rafter Void 11/2014 HH-TJ-FF-22 & HH-TJ-FF-23 DDED satisfy the relevant parts of the uilding Regulations applicable Thin Joint Junction Details (full Fill) INDEX Y. DRWN Y HEKED Y N.T.S.

2 full fill cavity elcon thin joint blocks* to inner leaf, above dpc perimeter insulation to provide minimum resistance of 0.8m²K/W traditional mtar base course incpating dpm and dpc cavity to continue at least 215mm from top of beam dpc dpm max. 75mm screed thickness flo insulation to tightly abut wall blockwk precast beam and block flo with elcon Standard infill blocks ventilated void elcon infill blocks built into walls to have the same compressive strength as wall blocks elcon blocks and traditional mtar below ground elcon foundation blocks L NOTE DDED LOK FORMTS NOTE REVISED 11/2013 MX. SREED THIKNESS NOTE DDED Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0022 L Registered onstruction Details E5MFF Full Fill - Suspended eam nd lock Flo, Insulation bove Slab DRWN Y HH-TJ-FF-01 HEKED Y

3 full fill cavity elcon thin joint blocks* to inner leaf, above dpc traditional mtar base course incpating lapped dpm and dpc cavity to continue at least 215mm below underside of slab dpc dpm flo insulation to tightly abut wall blockwk elcon blocks and traditional mtar below ground MX. FLOOR THIKNESS NOTE 11/2014 REMOVED. L REFERENE DDED. elcon foundation blocks LOK FORMTS NOTE REVISED 11/2013 MX. FLOOR THIKNESS NOTE DDED Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0023 L Registered onstruction Details E5MFF Full Fill - Suspended In-Situ oncrete Flo, Insulation elow Slab DRWN Y HH-TJ-FF-02 HEKED Y

4 full fill cavity elcon thin joint blocks* to inner leaf, above dpc traditional mtar base course incpating lapped dpm and dpc to continue at least 215mm below underside of slab dpc perimeter insulation to provide minimum resistance of 0.8m²K/W dpm flo insulation to tightly abut wall blockwk elcon blocks and traditional mtar below ground MX. FLOOR THIKNESS NOTE 11/2014 REMOVED. L REFERENE DDED LOK FORMTS NOTE REVISED 11/2013 MX. FLOOR THIKNESS NOTE DDED Y. elcon foundation blocks Jumbo lok = 630mm x 250mm see onstructive Details D0024 L Registered onstruction Details E5MFF satisfy the relevant parts of the uilding Regulations applicable DRWN Y Full Fill - oncrete Ground earing Flo, Insulation elow Slab HH-TJ-FF-03 HEKED Y

5 elcon thin joint blocks* to inner leaf full fill cavity minimum frame overlap 30mm external lintel internal lintel PV-U cavity closer fully insulated 11/2014 L NOTE DDED LOK FORMTS NOTE REVISED Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0025 L Registered onstruction Details E2MFF4-6. DRWN Y Full Fill - Independent Lintel HH-TJ-FF-04 HEKED Y

6 elcon thin joint blocks* to inner leaf full fill cavity minimum frame overlap 30mm insulated steel lintel with perfated base plate (equivalent conductivity 30W/mK less) soffit insulation with min. resistance of 0.6m²K/W MX. LINTEL HEIGHT NOTE 11/2014 REMOVED. LINTEL SEPLTE DDED. L REFERENE DDED LOK FORMTS NOTE REVISED Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0026 L Registered onstruction Details E1MFF4-6. DRWN Y Full Fill - Steel Lintel, Perfated ase Plate, (Insulated Soffit) HH-TJ-FF-05 HEKED Y

7 ircrete blocks to inner leaf full fill cavity minimum frame overlap 30mm insulated steel lintel no continuous base plate, max steel thickness 3.0mm Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see L Registered onstruction Details E2MFF7-9. DRWN Y HH-TJ-FF-22 Nov 2014 HEKED Y Full Fill - Steel Lintel, Open ack, (no continuous base plate) 0

8 Jumbo lok = 630mm x 250mm minimum frame overlap 30mm full fill cavity PV-U cavity closer, fully insulated elcon thin joint blocks* to inner leaf see onstructive Details D0027 L Registered onstruction Details E3MFF4-6. DRWN Y 11/2014 L NOTE DDED LOK FORMTS NOTE REVISED satisfy the relevant parts of the uilding Regulations applicable Full Fill - Sill HH-TJ-FF-06 HEKED Y Y.

9 full fill cavity 300mm max. elcon thin joint blocks* to inner leaf PV-U cavity closer, fully insulated L NOTE DDED. minimum frame overlap 30mm LOK FORMTS NOTE REVISED satisfy the relevant parts of the uilding Regulations applicable Y. Jumbo lok = 630mm x 250mm see onstructive Details D0028 L Registered onstruction Details E4MFF4-6. DRWN Y Full Fill - Jamb HH-TJ-FF-07 HEKED Y

10 elcon thin joint blocks* to inner leaf full fill cavity Jumbo lok = 630mm x 250mm timber flo joists may be built into inner block leaf suppted on joist hangers see onstructive Details D0029 L Registered onstruction Details E6MFF4-6. DRWN Y L NOTE DDED LOK FORMTS NOTE REVISED satisfy the relevant parts of the uilding Regulations applicable Full Fill - Intermediate Timber Flo Within Dwelling HH-TJ-FF-08 HEKED Y Y.

11 full fill cavity traditional mtar base course proprietary fire stop dpm elcon thin joint blocks* to inner leaf concrete screed precast concrete plank flo ceiling void 11/2014 PROPRIETRY FIRE STOP NOTE REVISED. L NOTE DDED LOK FORMTS NOTE REVISED Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0030 L Registered onstruction Details E7MFF4-6. Full Fill - Precast oncrete Separating Flo etween Dwellings DRWN Y HH-TJ-FF-09 HEKED Y

12 full fill cavity minimum 200mm above ceiling insulation elcon thin joint blocks* to inner leaf pack compressible insulation between last truss and wall ceiling insulation L NOTE DDED LOK FORMTS NOTE REVISED Jumbo lok = 630mm x 250mm see onstructive Details D0031 L Registered onstruction Details E12MFF4-6. Full Fill - Pitched Roof, Gable - Insulation t eiling Level, Ventilated Loft DRWN Y satisfy the relevant parts of the uilding Regulations applicable HH-TJ-FF-10 HEKED Y Y.

13 fill this void with insulation breathable roof membrane 100mm minimum proprietary fire stop if required min. 150mm rafters void fully filled with insulation insulation under rafters (optional) PROPRIETRY FIRE STOP NOTE REVISED. L NOTE DDED LOK FORMTS NOTE REVISED full fill cavity Jumbo lok = 630mm x 250mm pack compressible insulation between last rafter and wall elcon thin joint blocks* to inner leaf see onstructive Details D0032 L Registered onstruction Details E13MFF4-6. Full Fill - Pitched Roof, Gable - Insulation t Rafter Level, Unventilated Rafter Void DRWN Y 11/2013 satisfy the relevant parts of the uilding Regulations applicable HH-TJ-FF-11 RFTERS INSULTION THIKNESS NOTE DDED HEKED Y Y.

14 min. 50mm insulation between wall plate and vent proprietary ventilat between rafters insulation to entirely fill eaves gap between wall insulation and ceiling insulation ventilated loft ceiling insulation between and over roof trusses full fill cavity Jumbo lok = 630mm x 250mm proprietary fire stop if required elcon thin joint blocks* inner leaf see onstructive Details D0033 L Registered onstruction Details E10MFF4-6. WLL PLTE INSULTION OVER 11/2013 NOTE MOVED Full Fill - Pitched Roof, Eaves - Insulation t eiling Level, Ventilated Loft DRWN Y PROPRIETRY FIRE STOP NOTE REVISED. L NOTE DDED LOK FORMTS NOTE REVISED satisfy the relevant parts of the uilding Regulations applicable HH-TJ-FF-12 HEKED Y Y.

15 breathable roof membrane insulation to entirely fill eaves gap between and ceiling insulation 150mm min. rafters with insulation between, to sloping ceiling section insulation under rafters (optional) full fill cavity Jumbo lok = 630mm x 250mm proprietary fire stop if required elcon thin joint blocks* to inner leaf see onstructive Details D0034. RFTERS INSULTION NOW 11/2013 SHOWN S 150mm. Full Fill - Pitched Roof, Eaves - Insulation t Rafter Level, Unventilated Rafter Void DRWN Y PROPRIETRY FIRE STOP NOTE REVISED LOK FORMTS NOTE REVISED satisfy the relevant parts of the uilding Regulations applicable HH-TJ-FF-13 HEKED Y Y.

16 breathable roof membrane insulation to entirely fill eaves gap between and ceiling insulation 150mm rafters with insulation of λ = 0.044W/mK between, to sloping ceiling section 50mm insulation under rafters, max λ = 0.022W/mK ircrete blocks to inner leaf full fill cavity satisfy the relevant parts of the uilding Regulations applicable Y. Jumbo lok = 630mm x 250mm see L Registered onstruction Details E11MFF4-6. Full Fill - Pitched Roof, Eaves - Insulation t Rafter Level, Unventilated Rafter Void DRWN Y HH-TJ-FF-23 Nov HEKED Y

17 full fill cavity elcon thin joint blocks* to inner leaf L NOTE DDED LOK FORMTS NOTE REVISED Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0035 L Registered onstruction Details E16MFF4-6. DRWN Y Full Fill - Nmal ner HH-TJ-FF-14 HEKED Y

18 elcon thin joint blocks* to inner leaf L NOTE DDED LOK FORMTS NOTE REVISED Y. full fill cavity satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0036 L Registered onstruction Details E17MFF4-6. DRWN Y Full Fill - Inverted ner HH-TJ-FF-15 HEKED Y

19 cavity width min. 75mm up to 100mm max. (subject to Robust Detail requirements) 2 x 100mm thin joint leaves* to separating wall above dpc: elcon Standard (3.6N/mm²) elcon High Strength (7.3N/mm²) elcon Super Strength (8.7N/mm²) 8mm parge coat may be omitted (subject to Robust Detail requirements) full fill mineral wool cavity wall insulation, density up to 40kg/m³ elcon thin joint blocks* to inner leaf separating wall ties to be ncon Staifix HRT4 OR lan PWT4 PROPRIETRY FIRE STOP NOTE REVISED. L NOTE DDED LOK FORMTS NOTE REVISED Y. proprietary insulated fire stop if required full fill cavity satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0037 L Registered onstruction Details E18MFF7-10. Full Fill - Party Wall etween Dwellings DRWN Y HH-TJ-FF-16 HEKED Y

20 cavity width min. 75mm up to 100mm max. (subject to Robust Detail requirements) separating wall ties to be ncon Staifix HRT4 OR lan PWT4 traditional mtar base course incpating dpm and dpc insulation to continue at least 215mm below top of beams dpm elcon blocks and traditional mtar below dpc ventilated void dpm 2 x 100mm thin joint leaves* to separating wall above dpc: elcon Standard (3.6N/mm²) elcon High Strength (7.3N/mm²) elcon Super Strength (8.7N/mm²) 8mm parge coat may be omitted (subject to Robust Detail requirements) full fill mineral wool cavity, density up to 40kg/m³ perimeter insulation to provide minimum resistance of 0.8m²K/W max. 75mm screed thickness flo insulation to tightly abut wall blockwk precast beam and block flo with elcon Standard infill blocks elcon infill block built into walls to have the same compressive strength as wall blocks minimum 225mm L NOTE DDED LOK FORMTS NOTE REVISED MX. SREED THIKNESS NOTE 11/2013 DDED elcon foundation blocks Jumbo lok = 630mm x 250mm see onstructive Details D0017 L Registered onstruction Details P1PFF1-2. DRWN Y satisfy the relevant parts of the uilding Regulations applicable Party Wall Masonry, Full Fill - Suspended eam nd lock Flo, Insulation bove Slab HH-TJ-PW-17 Nov 2012 HEKED Y Y.

21 , cavity width min. 75mm up to 100mm max. (subject to Robust Detail requirements) 8mm parge coat may be omitted (subject to Robust Detail Requirement) elcon blocks and traditional mtar below ground 2 x 100mm thin joint leaves* to separating wall above dpc: elcon Standard (3.6N/mm²) elcon High Strength (7.3N/mm²) elcon Super Strength (8.7N/mm²) full fill mineral wool cavity wall insulation, density up to 40kg/m³ separating wall ties to be ncon Staifix HRT4 lan PWT4 traditional mtar base course incpating lapped dpm and dpc dpm dpm flo insulation to tightly abut wall blockwk insulation to continue at least 215mm below underside of slab MX. FLOOR THIKNESS NOTE 11/2014 REMOVED. L REFERENE DDED LOK FORMTS NOTE REVISED MX. FLOOR THIKNESS NOTE 11/2013 DDED elcon foundation blocks Jumbo lok = 630mm x 250mm see onstructive Details D0018 L Registered onstruction Details P1PFF3-4. DRWN Y Party Wall Masonry, Full Fill - Suspended oncrete Flo, Insulation elow Slab HH-TJ-PW-18 Nov 2012 satisfy the relevant parts of the uilding Regulations applicable HEKED Y Y.

22 cavity width min. 75mm up to 100mm max. (subject to Robust Detail requirements) 8mm parge coat may be omitted (subject to Robust Detail Requirement) 2 x 100mm thin joint leaves* to separating wall above dpc: elcon Standard (3.6N/mm²) elcon High Strength (7.3N/mm²) elcon Super Strength (8.7N/mm²) separating wall ties to be ncon Staifix HRT4 lan PWT4 traditional mtar base course incpating lapped dpm and dpc elcon blocks and traditional mtar below ground full fill mineral wool cavity wall insulation, density up to 40kg/m³ perimeter insulation to provide minimum resistance of 0.8m²K/W dpm dpm flo insulation to tightly abut wall blockwk insulation to continue at least 215mm below underside of slab MX. FLOOR THIKNESS NOTE 11/2014 REMOVED. L REFERENE DDED LOK FORMTS NOTE REVISED 11/2013 MX. FLOOR THIKNESS NOTE DDED Y. satisfy the relevant parts of the uilding Regulations applicable elcon foundation blocks Jumbo lok = 630mm x 250mm see onstructive Details D0019 L Registered onstruction Details P1PFF5-6. Party Wall Masonry, Full Fill - In-situ oncrete Ground earing Flo, Insulation elow Slab DRWN Y HH-TJ-PW-19 Nov 2012 HEKED Y

23 cavity width min. 75mm up to 100mm max. (subject to Robust Detail requirements) 2 x 100mm thin joint leaves* to separating wall above dpc: elcon Standard (3.6N/mm²) elcon High Strength (7.3N/mm²) elcon Super Strength (8.7N/mm²) separating wall ties to be ncon Staifix HRT4 lan PWT4 minimum 200mm wall insulation above ceiling insulation pack compressible insulation between last rafter and wall ceiling insulation 8mm parge coat may be omitted (subject to Robust Detail requirements) full fill mineral wool cavity, density up to 40kg/m³ L NOTE DDED LOK FORMTS NOTE REVISED Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0020 L Registered onstruction Details P4PFF1-2. DRWN Y Party Wall Masonry, Full Fill - Roof, Insulated t eiling Level, Ventilated Loft HH-TJ-PW-20 Nov 2012 HEKED Y

24 minimum 100mm insulation breathable roof membrane insulation under rafters (optional) separating wall ties to be ncon Staifix HRT4 lan PWT4 2 x 100mm thin joint leaves* to separating wall: elcon Standard (3.6N/mm²) elcon High Strength (7.3N/mm²) elcon Super Strength (8.7N/mm²) cavity width min. 75mm, up to 100mm max. (subject to Robust Detail requirements) min. 150mm rafters void fully filled with insulation with max. λ = 0.040W/mK pack compressible insulation between last rafter and wall 8mm parge coat may be omitted (subject to Robust Detail requirements) full fill mineral wool cavity, density up to 40kg/m³ RFTERS INSULTION THIKNESS 11/2013 NOTE DDED L NOTE DDED LOK FORMTS NOTE REVISED Y. satisfy the relevant parts of the uilding Regulations applicable Jumbo lok = 630mm x 250mm see onstructive Details D0021 L Registered onstruction Details P5PFF1-2. DRWN Y Party Wall Masonry, Full Fill - Roof, Insulated t Rafter Level, Unventilated Rafter Void HH-TJ-PW-21 Nov 2012 HEKED Y

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5 Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame

More information

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance

More information

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture Rochdale Building Control Guide Approved Document C Site preparation and resistance to contaminants and moisture Dampness is often misdiagnosed within buildings, the approved document deals with prevention

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

fire separating walls #2

fire separating walls #2 210108 fire separating walls #2 ISSUE BSA has identified a number of instances of defective fire separating walls in duplexes, town houses and multi-residential complexes. The system of fire separating

More information

Conventions for U-value calculations

Conventions for U-value calculations Conventions for U-value calculations 2006 edition Brian Anderson BRE Scotland BRE is committed to providing impartial and authoritative information on all aspects of the built environment for clients,

More information

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,

More information

Building Control Guidance Note

Building Control Guidance Note Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you

More information

Domestic Extensions. Monmouthshire County Council. Building control guidance document

Domestic Extensions. Monmouthshire County Council. Building control guidance document Monmouthshire County Council Building control guidance document Domestic Extensions Building Regulations 2010 (with 2013 amendments) For use in Wales May 2013 Edition Guidance produced for Monmouthshire

More information

The Pocket Guide To Insulation August 2013

The Pocket Guide To Insulation August 2013 The Pocket Guide To Insulation August 2013 Introduction Knauf Insulation is the UK s leading manufacturer of insulation products, including: Earthwool glass and rock mineral wool Polyfoam ECO extruded

More information

0331 Brick and block construction

0331 Brick and block construction 0331 BRICK AND BLOCK CONSTRUCTION This worksection has been written for Class 1 and 10a buildings that fully conform to the scope of AS 4773.1. If the works include isolated structures, (totally separate

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

Building Regulations for the Conservation of Fuel and Power

Building Regulations for the Conservation of Fuel and Power Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction

More information

The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES

The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES Crown copyright 2006 Cover designed and produced by Astron Text pages

More information

Additions and Alterations

Additions and Alterations Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal

More information

The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES 2 ND EDITION

The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES 2 ND EDITION The Scottish Building Standards TECHNICAL HANDBOOK CONSERVATORIES 2 ND EDITION CONTENTS Page 1 STATUS OF THIS DOCUMENT 3 2 WHEN YOU CAN USE THIS DOCUMENT 4 3 INTRODUCTION 5 4 SUBSOIL CONDITIONS 6 5 FOUNDATIONS

More information

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors W42_Stand_Extra_32 15/3/05 9:17 am Page 2 NHBC s technical newsletter April 2005 Issue 32 This edition includes: 2 House building is changing fast NHBC unveils new Standards Chapters on curtain walling

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

The Kingspan Insulation Price List 1 st January 2013

The Kingspan Insulation Price List 1 st January 2013 Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings

More information

Superform Products Ltd.

Superform Products Ltd. TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000

More information

Including. Rubershield-Pro. Breather Membrane

Including. Rubershield-Pro. Breather Membrane Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against

More information

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Innovation - High performance roof, wall and floor insulation board. delivering better performance

Innovation - High performance roof, wall and floor insulation board. delivering better performance 2010 VERSION 1 IRL High performance roof, wall and floor insulation board Innovation - delivering better performance PRODUCT SPECIFICATION INSTALLATION GUIDE I ve worked with Xtratherm for years, they

More information

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces CI/SfB Km1 (K22) November 2006 (replaces July 2005 issue) Construction type Cavity Barriers Fire Barrier Systems For inhibiting the spread of fire and smoke in concealed spaces As part of the comprehensive

More information

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS SITE C SHOPPING CENTRE, KHAYELITSHA PROJECT NO 2369 Project Specification Refer all queries to: John Meiring Tel: +27 21 425 0065 REVISION P01 E-mail:

More information

FOREST OF DEAN DISTRICT COUNCIL BUILDING CONTROL SERVICES. Building Control Guidance for. Loft Conversions

FOREST OF DEAN DISTRICT COUNCIL BUILDING CONTROL SERVICES. Building Control Guidance for. Loft Conversions FOREST OF DEAN DISTRICT COUNCIL BUILDING CONTROL SERVICES Building Control Guidance for Loft Conversions 1ST EDITION - AUGUST 2008 About this document This document intends to provide education and guidance

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1 Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.

More information

CHAPTER 6 CONSTRUCTION TYPES

CHAPTER 6 CONSTRUCTION TYPES CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use

More information

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE STRUCTURAL INSPECTION REPORT DRAFT 201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE TOWN OF PRESCOTT Date: November 2013 GENIVAR No.: 131-20617-00 2611 Queensview Drive, Suite 300, Ottawa,

More information

DEFAULT HEAT LOSS COEFFICIENTS

DEFAULT HEAT LOSS COEFFICIENTS DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables

More information

TGD L 2011. Limiting Thermal Bridging and Air Infiltration. Acceptable Construction Details. Introduction

TGD L 2011. Limiting Thermal Bridging and Air Infiltration. Acceptable Construction Details. Introduction TGD L 2011 Limiting Thermal Bridging and Air Infiltration Acceptable Construction Details Introduction Government of Ireland 2015 1 INTRODUCTION This guide to Acceptable Construction Details (ACDs) is

More information

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

British Gypsum Guide to Timber Frame Construction. March 1998

British Gypsum Guide to Timber Frame Construction. March 1998 British Gypsum Guide to Timber Frame Construction March 1998 Timber frame construction has a centuries long tradition in the UK, however, over the last 80 years it has continuously evolved to meet the

More information

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com CI/SfB (31.9) Hh2 BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE www.iglintels.com BETTER BY DESIGN IG produce the UK s largest range of steel lintels backed by industry leading

More information

domestic structure SBSG 2007 ANNEX C

domestic structure SBSG 2007 ANNEX C domestic structure SBSG 2007 ANNEX C Small buildings structural guidance 1.A General 1.B Stability 1.C Foundations 1.D Masonry walls 1.E Timber frame walls 1.F Timber floor and roof members contents domestic

More information

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two Factors governing type selection Economics not necessarily the one that requires the least structural

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

How To Build A Gambrel Roof And A Gable End Roof

How To Build A Gambrel Roof And A Gable End Roof Dutch Gable or Gambrel Roof and The Scotch Valley The folowing pages are an extract from Carp 12 text TAFE NSW Construction and Transport Division 71 HIP and VALLEY ROOFING GAMBREL / DUTCH GABLE The effect

More information

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................

More information

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes

More information

BUILDING CONTROL GUIDANCE FOR DOMESTIC LOFT CONVERSIONS

BUILDING CONTROL GUIDANCE FOR DOMESTIC LOFT CONVERSIONS BUILDING CONTROL GUIDANCE FOR DOMESTIC LOFT CONVERSIONS OCTOBER 2010 EDITION 4-1 - Introduction This document intends to provide education and guidance on how some of the technical design and construction

More information

BUILDING CONTROL GUIDANCE FOR NEW DWELLINGS & GARAGES

BUILDING CONTROL GUIDANCE FOR NEW DWELLINGS & GARAGES BUILDING CONTROL GUIDANCE FOR NEW DWELLINGS & GARAGES Dwellings upto 2 storeys with additional guidance for 3 storeys OCTOBER 2010: EDITION 5 Introduction This document intends to provide education and

More information

PRESTRESSED CONCRETE FLOORING BEAMS

PRESTRESSED CONCRETE FLOORING BEAMS PRESTRESSED CONCRETE FLOORING BEAMS TRIED & TRUSTED Introduction Established in 2001 TT Concrete Products Limited has become a prominent manufacturer of prestressed concrete flooring beams throughout the

More information

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Leaky Homes Financial Assistance Package (FAP) Repair plan example LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended

More information

Timber Frame Construction

Timber Frame Construction Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction

More information

Foundations and Substructures

Foundations and Substructures Ground workers handbook Foundations and Substructures Introduction The Ground Workers Handbook gives guidance to site managers and site staff on any particular issues on your site for traditional forms

More information

Building Construction. Lightweight construction. Conventional Construction

Building Construction. Lightweight construction. Conventional Construction Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.

More information

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS CONTENTS Introduction 2 Applications 3 Advantages 3 Components 3 6 Design Considerations 7 8 System Features 10 Typical installation Sequence

More information

Part 7 Roofs. Chapter 7.2. Pitched roofs. Effective from 1 January 2012

Part 7 Roofs. Chapter 7.2. Pitched roofs. Effective from 1 January 2012 Part 7 Roofs Chapter Effective from 1 January 2012 CONTENTS SCOPE DESIGN Clause Page Design standards D1 1 Statutory requirements D2 1 Loadbearing structure D3-D4 1 Trussed rafter roofs D5 1 Traditional

More information

This seminar covers the principles, design and installation of ground bearing and suspended insulated floors. You will discover

This seminar covers the principles, design and installation of ground bearing and suspended insulated floors. You will discover Dow Construction Products Thermal Insulation of Floors This seminar covers the principles, design and installation of ground bearing and suspended insulated floors. You will discover Why a floor should

More information

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.

More information

FCA CARPENTRY & JOINERY THEORY. 10 SIMPLE ROOF CONSTRUCTION Part 2

FCA CARPENTRY & JOINERY THEORY. 10 SIMPLE ROOF CONSTRUCTION Part 2 CARPENTRY & JOINERY FCA CARPENTRY & JOINERY THEORY 10 SIMPLE ROOF Double Roofs A double roof is a roof whose rafters are of such a length that they require an intermediate support. This support is usually

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information

Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors

Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors Best Practice in Steel Construction - Industrial Residential Buildings Contents The Steel Construction Institute (SCI) develops and promotes the effective use of steel in construction. It is an independent,

More information

technology UICK progressive sustainable any design, any shape, any colour, anywhere you like!

technology UICK progressive sustainable any design, any shape, any colour, anywhere you like! uality using advanced building technology UICK uality innovative progressive sustainable any design, any shape, any colour, anywhere you like! 2 NicheQ is an award winning progressive and innovative builder

More information

Lintel Product Selector

Lintel Product Selector Uniclass L325:P4142 Cl/Sfb October 2014 EPIC F631:X442 (31.9) Hh2 www.catnic.com Lintel Product Selector October 2014 Care has been taken to ensure that the contents of this publication are accurate, but

More information

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against

More information

CARPENTRY - HOUSING. This is the sloping length of a right-angled triangle.

CARPENTRY - HOUSING. This is the sloping length of a right-angled triangle. CARPENTRY - HOUSING PART 2: GABLE ROOFS The gable roof is classified as being double-pitched and one of the simplest roof forms, due to the fact that all rafters in the roof are exactly the same length

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE

NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE NEW AUSTRALIAN STANDARDS FOR MASONRY IN SMALL STRUCTURES S.J. LAWRENCE Conjoint Professor Centre for Infrastructure Performance and Reliability The University of Newcastle Callaghan, NSW, Australia A.W.

More information

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section

More information

Residential Foundations and Basements

Residential Foundations and Basements Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article

More information

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING 6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

Extension. for. Pretend Customer 123 A Road HA7 9BP. at: 123 A Road HA7 9BP

Extension. for. Pretend Customer 123 A Road HA7 9BP. at: 123 A Road HA7 9BP for Pretend Customer at: Pretend Customer Site address: Monday, 23 November 2015 Dear Pretend Customer, Subject: Thank you for your valued enquiry and instructions to quote for the above project. We are

More information

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional

More information

FIBRANgeo. Stonewool thermal insulation, sound insulation and fire protection products for building applications

FIBRANgeo. Stonewool thermal insulation, sound insulation and fire protection products for building applications 00 product catalogue Stonewool thermal insulation, sound insulation and fire protection products for building applications stonewool building insulation Manufacturing of stonewool products are industrially

More information

EAST LYME HIGH SCHOOL

EAST LYME HIGH SCHOOL Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed

More information

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. STEP-BY-STEP construction guide Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. Welcome to our CONSERVATORY AND SUNROOM CONSTRUCTION GUIDE What is the specification

More information

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Fourth Issue March 2011 TR21 INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT AND MASTIC ASPHALT High performance rigid thermoset insulation

More information

Roofers Guide to Underslating Membranes

Roofers Guide to Underslating Membranes Roofers Guide to Underslating Membranes IKO is a worldwide enterprise, with more than 3000 employees, and manufacturing plants in Canada, the United States, United Kingdom, Belgium, Holland, France and

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

Sample Drawing Package for One and Two Family Dwelling Applications

Sample Drawing Package for One and Two Family Dwelling Applications Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx

More information

ISO Types 1-6: Construction Code Descriptions

ISO Types 1-6: Construction Code Descriptions ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with

More information

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description

More information

CLEARLY SETS OUT WHO IS RESPONSIBLE FOR EACH AREA OF THE CONSTRUCTION

CLEARLY SETS OUT WHO IS RESPONSIBLE FOR EACH AREA OF THE CONSTRUCTION SCANDIA-HUS FACT SHEET NO. 4 MATERIAL & COMPONENT SPECIFICATION DATE: 1 ST FEBRUARY 2016 ISSUE NO: 20 THIS FACT SHEET SHOULD BE READ IN CONJUNCTION WITH OUR SHELL ERECTION SCHEDULE FACT SHEET NO. 13 -

More information

Low Energy Low Carbon Buildings

Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Eighth Issue March 2011 TR27 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY, PARTIALLY BONDED BUILT UP FELT, MASTIC ASPHALT AND COLD

More information

Building Control Guidance Note

Building Control Guidance Note Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material

More information

Structural Assessment Report

Structural Assessment Report Report Dallas Township Elementary School Dallas, Pennsylvania (JBCI Project No. 144911) 1655 Suburban Station Building 1617 John F. Kennedy Boulevard Philadelphia PA 19103 215 665 0497 5 Sandwood Drive

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

How To Certify The Scottsdale Construction System

How To Certify The Scottsdale Construction System BRE CERTIFICATION LIMITED PRODUCT SCOTTSDALE CONSTRUCTION SYSTEM CERTIFICATE NUMBER 129/07 DATE OF ISSUE December 2007 SUPPLIED BY Scottsdale Construction System Ltd SUMMARY The Scottsdale Construction

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

- 1 - Element Type. 9 mm gypsum board, 50 mm mineral wool (glued) 9 mm gypsum board, 50 mm mineral wool (on wooden studs, at 300 mm centres)

- 1 - Element Type. 9 mm gypsum board, 50 mm mineral wool (glued) 9 mm gypsum board, 50 mm mineral wool (on wooden studs, at 300 mm centres) concrete 160 mm concrete 180 mm concrete 200 mm concrete 220 mm concrete 230 mm concrete 240 mm concrete 260 mm calcium silicate block 214 mm calcium silicate block 240 mm calcium silicate block 265 mm

More information

If stepping is required, step at 180mm as seen in this picture.

If stepping is required, step at 180mm as seen in this picture. Cast Foundations to standard building regulations requirements. Foundations must be cast completely level, 600mm wide by 230mm deep for single storey, double storey is not allowed by NHBRC. If stepping

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

Ubiflex. Non-lead flashing system

Ubiflex. Non-lead flashing system Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof

More information

Squash Court Design general points

Squash Court Design general points Squash Court Design general points Contents: Contents:... 1 1. Squash Court Dimensions... 2 2. CourtTech Walls... 3 3. Dimensional requirements for courts with CourtTech Walls... 3 4. Loading of CT System

More information

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare? Value assessment. The right solutions. We Believe We believe that Porotherm offers both short and long term value to all involved in the building process - from bricklayer to client and everyone in between.

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE 86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is