How To Make A 3Ra3 Power Supply From A 3Rd Generation Power Supply (Power Supply)

Size: px
Start display at page:

Download "How To Make A 3Ra3 Power Supply From A 3Rd Generation Power Supply (Power Supply)"

Transcription

1 3RA3 Reversing Contactor Assemblies SIRIUS 3R Overview The 3RA3 reversing contactor assemblies can be ordered as follows:, open type, with mechanical and electrical interlock. ) As components for customer assembly. There is also a range of accessories (auxiliary switch blocks, surge suppressors, etc.) that must be ordered separately. For overload relays for motor protection, see Part. The contactor assemblies have screw connections and are available for screwing or snapping onto 3 mm standard mounting rails. The s and u approvals only apply to the complete contactor assemblies and not to the components for customer assembly. AC- and AC-3 utilization categories at AC 0 HZ 00 V kw A Size of contactors K-K Contactor K (clockwise) Contactor K (counterclockwise) 3 S00-S00 3RT0 3RT0 3RA3-8XB / 9 S00-S00 3RT0 3RT0 3RA3-8XB /. S00-S00 3RT0 3RT0 3RA3-8XB /. S0-S0 3RT0 3RT0 3RA3-8XB /. S0-S0 3RT0 3RT0 3RA3-8XB / S0-S0 3RT0 3RT0 3RA3-8XB / 3 S-S 3RT0 3 3RT0 3 3RA3 3-8XB / S-S 3RT0 3 3RT0 3 3RA3 3-8XB /3 0 S-S 3RT0 3 3RT0 3 3RA3 3-8XB /3 30 S3-S3 3RT0 3RT0 3RA3-8XB / 3 80 S3-S3 3RT0 3RT0 3RA3-8XB / 9 S3-S3 3RT0 3RT0 3RA3-8XB / Selection and ordering data See page AC and IEC 0 9, EN 0 9 (VDE 00) Design Complete equipment assemblies The fully wired reversing contactor assemblies are suitable for use in any climate. They are safe from touch to DIN VDE 0 Part 00. The contactor assemblies each consist of two contactors with identical ratings and one NC contact in the basic unit. The contactors are mechanically and electrically interlocked (NC contact interlock). The main and control circuits are wired according to the circuit diagrams on page 3/9. For motor protection, either 3RU overload relays for direct mounting or individual mounting or thermistor motor protection tripping units must be ordered separately. Components for customer assembly Installation kits for all sizes are available for customer assembly of reversing contactor assemblies. Contactors, overload relays, the mechanical interlock (as of size S0) and - for momentary-contact operation - auxiliary switch blocks for latching must be ordered separately. The following points should be noted: Size S00: For maintained-contact operation: use contactors with an NC contact in the basic unit for the electrical interlock. For momentary-contact operation: use contactors with an NC contact in the basic unit for the electrical interlock; in addition, an auxiliary switch block with at least one NO contact for latching is required per contactor. Sizes S0 to S3: For maintained-contact operation: the contactors have no auxiliary contact in the basic unit; NC contacts for the electrical interlock are therefore integrated in the mechanical interlock that can be mounted on the side of each contactor (one contact each for the left and right-hand contactors). For momentary-contact operation: the electrical interlock is the same as for maintained-contact operation; in addition, an auxiliary switch with one NO contact for latching is required per contactor. This contact can be snapped onto the top of the contactors. Alternatively, auxiliary switch blocks mounted on the side can be used; they must be fitted onto the outside of each contactor. If the front-mounted mechanical interlock is used for size S0 to S3 contactors, two location holes for single-pole auxiliary switch blocks are provided on the front of each S0 or S contactor, while three additional, single-pole auxiliary switch blocks can be snapped onto S3 contactors. The maximum auxiliary switch complements per contactor stated on page 3/ must not be exceeded. When size S and S3 contactors are combined with a frontmounted mechanical interlock, the 3RA9 33-B and 3RA9 3-B installation kits cannot be used. For accessories, see page 3/. For technical data, see page 3/8. For circuit diagrams, see page 3/9. For dimensions, see page 3/8. ) An additional dead interval of 0 ms is necessary on reversing at voltages > 00 V. Mode of operation The operating times of the individual 3RT0 contactors are rated in such a way that no overlapping of the contact making and the arcing time between two contactors can occur on reversing, providing they are interlocked via their auxiliary switches (NC contact interlock) and the operating mechanisms. An additional dead interval of 0 ms is necessary on reversing if the individual contactors are used at voltages > 00 V. The operating times of the individual contactors are not affected by the mechanical interlock. Surge suppression All contactor assemblies can be fitted with RC elements or varistors for damping opening surges in the coil. As with the individual contactors, the surge suppressors can either be plugged onto the top of the contactors (S00) or fitted onto the coil terminals on the top or bottom (S0 to S3). 3/0 Siemens NS K 000

2 SIRIUS 3R 3RA3 Reversing Contactor Assemblies Up to. kw Size S00 AC- and AC-3 utilization categories of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. 3 ) A kw kw kw kw Preferred type unit kg V, 0/0 Hz 3RA3-8XB30-AB V, 0/0 Hz 3RA3-8XB30-AF0 30 V, 0/0 Hz 3RA3-8XB30-AP V, 0/0 Hz 3RA3-8XB30-AB0 0 V, 0/0 Hz 3RA3-8XB30-AF0 30 V, 0/0 Hz 3RA3-8XB30-AP V, 0/0 Hz 3RA3-8XB30-AB0 0 V, 0/0 Hz 3RA3-8XB30-AF0 30 V, 0/0 Hz 3RA3-8XB30-AP DC V 3RA3-8XB30-BB DC V 3RA3-8XB30-BB The fully wired includes the following 3 NSK Solder pin adapter 3RT9-KA 3/3 mountable on the front 3RH /8 (only auxiliary switch blocks to DIN EN 0 00 can be used) Surge suppressor 3RT /3, 3/3 K K Contactors, 3 kw 3RT0 3RT0 3/0 Contactors, kw 3RT0 3RT0 3/0 Contactors,. kw 3RT0 3RT0 3/0 Installation kit 3RA93-A 3/ Mechanical interlock connecting clips for contactors for connecting the main conducting paths, electrical interlock included ), interruptible (NC contact interlock) For description, see page 3/0. For accessories, see page 3/. For technical data, see page 3/8. For circuit diagrams, see page 3/9. For dimensions, see page 3/8. ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. ) 3RT0. contactors with one NC contact in the basic unit are required for the electrical interlock. 3) The contactors integrated in the contactor assemblies have no unassigned auxiliary contacts. Siemens NS K 000 3/

3 3RA3 Reversing Contactor Assemblies SIRIUS 3R Up to kw Size S0 AC- and AC-3 utilization categories of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. A kw kw kw kw Preferred type unit kg 3... V, 0/0 Hz 3RA3-8XB30-AC 0. 0 V, 0/0 Hz 3RA3-8XB30-AG 30 V, 0/0 Hz 3RA3-8XB30-AL. 0 V, 0/0 Hz 3RA3-8XB30-AC 0 V, 0/0 Hz 3RA3-8XB30-AG 30 V, 0/0 Hz 3RA3-8XB30-AL. V, 0/0 Hz 3RA3-8XB30-AC 0 V, 0/0 Hz 3RA3-8XB30-AG 30 V, 0/0 Hz 3RA3-8XB30-AL 3... DC V 3RA3-8XB30-BB.. 0 DC V 3RA3-8XB30-BB. DC V 3RA3-8XB30-BB The fully wired includes the following NSK-88 mountable on the front 3RA9 -A 3/ mountable on the front 3RH9 -CA.. 3/8 laterally mountable 3RH9-EA.. 3/9 Surge suppressor 3RT /3 K K Contactors,. kw 3RT0 3RT0 3/0 Contactors,. kw 3RT0 3RT0 3/0 Contactors, kw 3RT0 3RT0 3/0 laterally mountable 3RA9 -B 3/ Installation kit 3RA93-A 3/ The installation kit contains wiring connectors on the top and bottom (they also form the mechanical connection between the contactors). For description, see page 3/0. For accessories, see page 3/. For technical data, see page 3/8. For circuit diagrams, see page 3/9. For dimensions, see page 3/8. ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. 3/ Siemens NS K 000

4 SIRIUS 3R 3RA3 Reversing Contactor Assemblies Up to kw Size S AC- and AC-3 utilization categories of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. A kw kw kw kw Preferred type unit kg V, 0/0 Hz 3RA3 3-8XB30-AC.8 0 V, 0/0 Hz 3RA3 3-8XB30-AG 30 V, 0/0 Hz 3RA3 3-8XB30-AL 0 8. V, 0/0 Hz 3RA3 3-8XB30-AC 0 V, 0/0 Hz 3RA3 3-8XB30-AG 30 V, 0/0 Hz 3RA3 3-8XB30-AL 0 30 V, 0/0 Hz 3RA3 3-8XB30-AC 0 V, 0/0 Hz 3RA3 3-8XB30-AG 30 V, 0/0 Hz 3RA3 3-8XB30-AL DC V 3RA3 3-8XB30-BB DC V 3RA3 3-8XB30-BB 0 30 DC V 3RA3 3-8XB30-BB The fully wired includes the following NSK-888 mountable on the front 3RA9 -A 3/ mountable on the front 3RH9 -CA.. 3/8 laterally mountable 3RH9-EA.. 3/9 Surge suppressor 3RT /33 3RT For description, see page 3/0. For accessories, see page 3/. For technical data, see page 3/8. For circuit diagrams, see page 3/9. For dimensions, see page 3/8. Siemens NS K 000 K K Contactors, kw 3RT0 3 3RT0 3 3/ Contactors, 8. kw 3RT0 3 3RT0 3 3/ Contactors, kw 3RT0 3 3RT0 3 3/ ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. laterally mountable 3RA9-B 3/ Installation kit 3RA9 33-A 3/ connecting clips for contactors with a clearance of 0 mm for connecting the main conducting paths 3/3

5 3RA3 Reversing Contactor Assemblies SIRIUS 3R Up to kw Size S3 AC- and AC-3 utilization categories of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. A kw kw kw kw Preferred type unit kg V, 0/0 Hz 3RA3-8XB30-AC V, 0/0 Hz 3RA3-8XB30-AG 30 V, 0/0 Hz 3RA3-8XB30-AL 80 3 V, 0/0 Hz 3RA3-8XB30-AC 0 V, 0/0 Hz 3RA3-8XB30-AG 30 V, 0/0 Hz 3RA3-8XB30-AL 9 V, 0/0 Hz 3RA3-8XB30-AC 0 V, 0/0 Hz 3RA3-8XB30-AG 30 V, 0/0 Hz 3RA3-8XB30-AL DC V 3RA3-8XB30-BB DC V 3RA3-8XB30-BB 9 DC V 3RA3-8XB30-BB The fully wired includes the following NSK-889 mountable on the front 3RA9 -A 3/ mountable on the front 3RH9 -CA.. 3/8 laterally mountable 3RH9 -EA.. 3/9 Surge suppressor 3RT /33 3RT For description, see page 3/0. For accessories, see page 3/. For technical data, see page 3/8. For circuit diagrams, see page 3/9. For dimensions, see page 3/8. ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. K K Contactors, 30 kw 3RT0 3RT0 3/ Contactors, 3 kw 3RT0 3RT0 3/ Contactors, kw 3RT0 3RT0 3/ laterally mountable 3RA9-B 3/ Installation kit 3RA9 3-A 3/ connecting clips for contactors with a clearance of 0 mm for connecting the main conducting paths 3/ Siemens NS K 000

6 SIRIUS 3R 3RA Contactor Assemblies for Star-Delta Starting Overview The 3RA contactor assemblies for star-delta starting can be ordered as follows:, open type, with electrical interlock, dead interval of up to 0 s on reversing (size S00 with electrical and mechanical interlocks). As components for customer assembly. A dead interval of 0 ms on reversing is already integrated in the time-delay relay function. There is also a range of accessories (auxiliary switch blocks, surge suppressors, etc.) that must be ordered separately. For overload relays for motor protection, see Part. The contactor assemblies have screw connections and are available for screwing or snapping onto 3 mm standard mounting rails. 3RA contactor assemblies have one unassigned NO contact, which is mounted onto the front of contactor K3. A solid-state time-delay auxiliary switch block is snapped onto the front of the complete contactor assemblies, size S00 up to. kw, while a time-delay relay is mounted onto the side of sizes S0 to S3,. kw to kw. AC- und AC-3 utilization categories at AC 0 HZ 00 V kw A Size of contactors K-K3-K Line contactor K Delta contactor K3 Star contactor K Selection and ordering data See page. S00-S00-S00 3RT0 3RT0 3RT0 3RA -8XB /. S00-S00-S00 3RT0 3RT0 3RT0 3RA -8XB / S0-S0-S0 3RT0 3RT0 3RT0 3RA 3-8XC-... 3/ 3 S0-S0-S0 3RT0 3RT0 3RT0 3RA -8XC-... 3/ 8. 0 S0-S0-S0 3RT0 3RT0 3RT0 3RA -8XC-... 3/ 0 S-S-S0 3RT0 3 3RT0 3 3RT0 3RA 3-8XC-... 3/8 30 S-S-S0 3RT0 3 3RT0 3 3RT0 3RA 3-8XC-... 3/ S-S-S 3RT0 3 3RT0 3 3RT0 3 3RA 3-8XC-... 3/9 8 S-S-S 3RT0 3 3RT0 3 3RT0 3 3RA 3-8XC-... 3/9 S3-S3-S 3RT0 3RT0 3RT0 3 3RA -8XC-... 3/0 0 S3-S3-S 3RT0 3RT0 3RT0 3 3RA -8XC-... 3/0 AC and Application Star-delta starting can only be used either if the motor normally operates in a delta connection or starts softly or if the load torque during star starting is low and does not increase sharply. On the star step the motors can carry approximately 0 % (class KL ) or 30 % (class KL 0) of their rated torque; the starting torque is approximately / 3 of that during direct on-line starting. The starting current is approximately to. times the rated motor current. The changeover from star to delta must not be effected until the motor has run up to rated speed. Drives which require this changeover to be performed earlier are unsuitable for stardelta starting. The ratings given in the above table are only applicable to motors with a starting current ratio of I A 8. I N and using either a 3RT9 -G or 3RT9 -G solid-state time-delay auxiliary switch block with a star-delta function or a PU 0 stardelta time-delay relay with a dead interval of approximately 0 ms on reversing. For the circuit diagrams for the main and control circuits, see page 3/93. The size selected for the installation kits for stardelta starting is determined by the line contactor. Design Components for customer assembly Installation kits with wiring connectors and, if necessary, mechanical connectors are available for contactor assemblies for star-delta starting. Contactors, overload relays, star-delta time-delay relays and auxiliary switches for the electrical interlock if required also feeder terminals, mechanical interlocks ) and baseplates must be ordered separately. The wiring installation kits for sizes S00 and S0 contain the top and bottom main conducting path connections between the line and delta contactors (top) and between the delta and star contactors (bottom). In the case of sizes S and S3 only the bottom main conducting path connection between the delta and star contactors is included in the wiring connector, owing to the larger conductor cross-section at the infeed. Motor protection Overload relays or thermistor motor protection tripping units can be used for overload protection. The overload relay can be either mounted onto the line contactor or separately fitted. It must be set to 0.8 times the rated motor current. Surge suppression All contactor assemblies can be fitted with RC elements, varistors or diode assemblies for damping opening surges in the coil. As with the individual contactors, the surge suppressors can either be plugged onto the top of the contactors (S00) or fitted onto the coil terminals on the top or bottom (S0 to S3). For accessories, see page 3/3. For technical data, see page 3/8. For circuit diagrams, see page 3/93. For dimensions, see page 3/83. ) Exception: The mechanical interlock between the delta and star contactors is included in the installation kit for size S00 contactor assemblies. Siemens NS K 000 3/

7 3RA Contactor Assemblies for Star-Delta Starting SIRIUS 3R Up to. kw Size S00-S00-S00 AC- and AC-3 utilization categories of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. A kw kw kw kw Preferred type unit kg V, 0/0 Hz 3RA -8XB3-AB V, 0/0 Hz 3RA -8XB3-AF0 30 V, 0/0 Hz 3RA -8XB3-AP V, 0/0 Hz 3RA -8XB3-AB0 0 V, 0/0 Hz 3RA -8XB3-AF0 30 V, 0/0 Hz 3RA -8XB3-AP DC V 3RA -8XB3-BB DC V 3RA -8XB3-BB The fully wired includes the following 3 NSK mountable on the front 3RH /8 Surge suppressor 3RT /3, 3/3 3-phase feeder terminal 3RA93-3K 3/3 K K3 K 3 Contactors,. kw 3RT0 3RT0 3RT0 3/0 3 Contactors,. kw 3RT0 3RT0 3RT0 3/0 Solid-state time-delay auxiliary switch block, mountable on the front 3RT9 -G. 3/30 9 Auxiliary switch block with one unassigned NO contact 3RH9 -BA0 3/8 Installation kit 3RA9 3-B 3/3 Mechanical interlock 3 connecting clips for connecting the main and control conducting paths For description, see page 3/. For accessories, see page 3/3. For technical data, see page 3/8. For circuit diagrams, see page 3/93. For dimensions, see page 3/83. ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. 3/ Siemens NS K 000

8 SIRIUS 3R 3RA Contactor Assemblies for Star-Delta Starting Up to 8. kw Size S0-S0-S0 AC- and AC-3 of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. A kw kw kw kw Preferred type unit kg.. 9 V, 0/0 Hz 3RA 3-8XC-AC. 0 V, 0/0 Hz 3RA 3-8XC-AG 30 V, 0/0 Hz 3RA 3-8XC-AL 3/0. / V, 0/0 Hz 3RA -8XC-AC 0 V, 0/0 Hz 3RA -8XC-AG 30 V, 0/0 Hz 3RA -8XC-AL.. 9 DC V 3RA 3-8XC-BB.0 3/0. / DC V 3RA -8XC-BB The fully wired includes the following NSK-89a laterally mountable 3RA9-B 3/ Solid-state time-delay auxiliary switch block, mountable on the front 3 ) 3RT9-G... 3/30 mountable on the front 3RA9 -A 3/ laterally mountable 3RH9-EA.. 3/9 Surge suppressor 3RT /3 3-phase feeder terminal 3RV9 -A 3/3 3-phase busbar 3RV9 -A 3/3 Push-in lug ) for time-delay relay for screw mounting 3RP9 03 Part K K3 K 3 Contactors, kw 3RT0 3RT0 3RT0 3/0 3 Contactors, /8. kw 3RT0 3RT0 3RT0 3/0 8 Time-delay relay, laterally mountable 3RP -N.30 / 9 Auxiliary switch block with unassigned NO contact 3RH9 -CA0 3/8 0 Auxiliary switch block for local control units 3RH9 -CA0 3 units 3RH9 -CA0 3/8 Installation kit 3RA9 3-B 3/3 Connecting clips for connecting the main conducting paths For description, see page 3/. For accessories, see page 3/3. For technical data, see page 3/8. For circuit diagrams, see page 3/93. For dimensions, see page 3/83. ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. ) Not included in scope of supply of complete contactor assemblies; available as accessory. 3) Possible in principle. If a solid-state time-delay auxiliary switch block is mounted onto the front of K3, an ordinary auxiliary switch block can only be mounted onto the side. Siemens NS K 000 3/

9 3RA Contactor Assemblies for Star-Delta Starting SIRIUS 3R Up to 30 kw Size S-S-S0 AC- and AC-3 utilization categories of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. A kw kw kw kw Preferred type unit kg 0/ 9. / V, 0/0 Hz 3RA 3-8XC-AC. 0 V, 0/0 Hz 3RA 3-8XC-AG 30 V, 0/0 Hz 3RA 3-8XC-AL 0/ 9. / DC V 3RA 3-8XC-BB 3.9 The fully wired includes the following NSK-89a 8 9 laterally mountable, depth must be adapted K3:. mm; K: 0 mm 3RA9-B 3/ Solid-state time-delay auxiliary switch block, mountable on the front 3 ) 3RT9-G... 3/30 laterally mountable 3RH9-EA.. 3/9 Surge suppressor 3RT /3 3RT /33 3-phase feeder terminal 3RV9 3-A 3/3 3-phase busbar 3RV9 3-A 3/3 Push-in lug ) for time-delay relay for screw mounting 3RP9 03 Part K K3 K 3 Contactors, /30 kw 3RT0 3 3RT03 3RT0 3/0 8 Time-delay relay, laterally mountable 3RP -N.30 / 9 Auxiliary switch block with one unassigned NO contact 3RH9 -CA0 3/8 0 Auxiliary switch block for local control units 3RH9 -CA0 3 units 3RH9 -CA0 3/8 Baseplate 3RA9 3-E 3/3 Installation kit 3RA9 33-C 3/3 The installation kit contains the star jumper on the top and the wiring jumper on the bottom for connecting the main conducting paths. For description, see page 3/. For accessories, see page 3/3. For technical data, see page 3/8. For circuit diagrams, see page 3/93. For dimensions, see page 3/83. ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. ) Not included in the scope of supply of the complete contactor assemblies; available as an accessory. 3) Possible in principle. If a solid-state time-delay auxiliary switch block is mounted onto the front of K3, a standard auxiliary switch block can only be mounted onto the side. 3/8 Siemens NS K 000

10 SIRIUS 3R 3RA Contactor Assemblies for Star-Delta Starting Up to kw Size S-S-S AC- and AC-3 utilization categories of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. A kw kw kw kw Preferred type unit kg V, 0/0 Hz 3RA 3-8XC-AC 3, 0 V, 0/0 Hz 3RA 3-8XC-AG 30 V, 0/0 Hz 3RA 3-8XC-AL 8 3 V, 0/0 Hz 3RA 3-8XC-AC 0 V, 0/0 Hz 3RA 3-8XC-AG 30 V, 0/0 Hz 3RA 3-8XC-AL DC V 3RA 3-8XC-BB. 8 3 DC V 3RA 3-8XC-BB The fully wired includes the following NSK-893a 8 9 laterally mountable 3RA9-B 3/ Solid-state time-delay auxiliary switch block, mountable on the front 3 ) 3RT9-G... 3/30 mountable on the front 3RA9 -A 3/ laterally mountable 3RH9-EA.. 3/9 Surge suppressor 3RT /33 3RT phase feeder terminal 3RV9 3-A 3/3 3-phase busbar 3RV9 3-A 3/3 Push-in lug ) for time-delay relay for screw mounting 3RP9 03 Part ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. Siemens NS K 000 ) Not included in the scope of supply of the complete contactor assemblies; available as an accessory. K K3 K 3 Contactors, 3 kw 3RT0 3 3RT03 3RT0 3 3/ 3 Contactors, kw 3RT0 3 3RT03 3RT0 3 3/ 8 Time-delay relay, laterally mountable 3RP -N.30 / 9 Auxiliary switch block with one unassigned NO contact 3RH9 -CA0 3/8 0 Auxiliary switch block for local control units 3RH9 -CA0 3 units 3RH9 -CA0 3/8 Baseplate 3RA9 3-F 3/3 Installation kit 3RA9 33-B 3/3 The installation kit contains the star jumper on the top and the wiring connector on the bottom for connecting the main conducting paths. 3) Possible in principle. If a solid-state time-delay auxiliary switch block is mounted onto the front of K3, a standard auxiliary switch block can only be mounted onto the side. 3/9

11 3RA Contactor Assemblies for Star-Delta Starting SIRIUS 3R Up to kw Size S3-S3-S AC- and AC-3 utilization categories of three-phase motors at 0 Hz and supply voltage ) at 00 V 30 V 00 V 00 V 90 V Order No. A kw kw kw kw Preferred type unit kg V, 0/0 Hz 3RA -8XC-AC.3 0 V, 0/0 Hz 3RA -8XC-AG 30 V, 0/0 Hz 3RA -8XC-AL V, 0/0 Hz 3RA -8XC-AC 0 V, 0/0 Hz 3RA -8XC-AG 30 V, 0/0 Hz 3RA -8XC-AL DC V 3RA -8XC-BB DC V 3RA -8XC-BB The fully wired includes the following NSK-89a 9 laterally mountable, depth must be adapted K3: 0 mm; K:. mm 3RA9 -B 3/ Solid-state time-delay auxiliary switch block, mountable on the front 3 ) 3RT9 -G... 3/30 laterally mountable 3RH9 -EA.. 3/9 Surge suppressor 3RT /33 Push-in lug ) for time-delay relay for screw mounting 3RP9 03 Part ) Coil voltage tolerance at 0 Hz: 0.8 to. x U s, at 0 Hz: 0.8 to. x U s. ) Not included in the scope of supply of the complete contactor assemblies; available as an accessory. 3) Possible in principle. If a solidstate time-delay auxiliary switch block is mounted onto the front of K3, a standard auxiliary switch block can only be mounted onto the side. K K3 K 3 Contactors, kw 3RT0 3RT0 3RT0 3 3/ 3 Contactors, kw 3RT0 3RT0 3RT0 3 3/ 8 Time-delay relay, laterally mountable 3RP -N.30 / 9 Auxiliary switch block with one unassigned NO contact 3RH9 -CA0 3/8 0 Auxiliary switch block for local control units 3RH9 -CA0 3 units 3RH9 -CA0 3/8 Baseplate 3RA9 -E 3/3 Installation kit 3RA9 3-C 3/3 The installation kit contains the star jumper on the top and the wiring jumper on the bottom for connecting the main conducting paths. 3/0 Siemens NS K 000

12 SIRIUS 3R 3RA3 Reversing Contactor Assemblies Accessories For Size Design Order No. Packing contactor Mechanical interlocks 3RA9 -A mounted onto contactors Type 3RT0, 3RT0 3, 3RT0, 3RT3, 3RT3 3, 3RT3 3RT0, 3RT0 3, 3RT0, 3RT3 S0, S, S3, S0, S, S3 S0, S, S3, S0 Laterally mountable ) with one auxiliary contact ( NC) each per contactor (only contactors of different sizes with no more than position can be combined. The mounting depth of the smaller contactor has to be adapted.) Mountable on the front ) of contactors of sizes S0 to S3 (must be used for contactors of the same size). Note: Size S0: The wiring connectors have to be mounted first. Sizes S and S3: Use 3RA9 3-C mechanical connectors. kg unit 3RA9 -B 0.0 unit unit 3RA9 -A 0.0 unit Installation kits for making 3-pole contactor assemblies 3RA9 3-A 3RT0 S00 Mechanical interlock connecting clips for contactors set 3RA9 3-A 0.0 set 3RA9 3-A 3RT0 S0 set 3RA9 3-A 0.0 set 3RA9 33-A 3RT0 3 S connecting clips for contactors set 3RA9 33-A 0.09 set 3RA9 3-A 3RT0 S3 connecting clips for contactors set 3RA9 3-A 0. set ) Can also be used for size S and S3 -pole contactors (not suitable for mounting on size S0 3RT weld-free contactors.) ) Can also be used for size S0 -pole contactors. Siemens NS K 000 Only supplied in packings 3/

13 3RA3 Reversing Contactor Assemblies SIRIUS 3R Accessories For Size Contactor Design Order No. Packing contactors clearance Type unit kg Units Wiring connectors (can be ordered separately) 3RT0 0 mm Top (in-phase) 3RA9 3-3D S00 S00 Bottom (phase reversal) 3RA9 3-3E 3RT0 0 mm Top (in-phase) 3RA9 3-3D S0 S0 Bottom (phase reversal) 3RA9 3-3E and and S0 S0 0 mm 3RT0 3 0 mm Top (in-phase) S S Bottom (phase reversal) 3RT0 0 mm Top (in-phase) Bottom (phase reversal) S3 S3 3RA9 33-3D 3RA9 33-3E 3RA9 3-3D 3RA9 3-3E For Size Contactor Interlock Design Order No. Packing contactors clearance Type pack kg Packs Mechanical connectors pack = 0 units for 0 assemblies 3RA9 -H 3RT. 0 mm Laterally For -pole contactors 3RA9 -H ) S00 S00 mountable 3RA9 -C 3RT. 0 mm ) Mountable on S0 S0 front ) For 3 and -pole contactors 3RA9 -C 3RA9 3-C 3RT. 3 0 mm Mountable on S S front For 3-pole contactors 3RA9 3-C 3RA9 3-D 3RA9 3-G S 0 mm Laterally mountable For 3-pole contactors For -pole contactors 3RA9 3-D 3RA9 3-G 3RT. 0 mm Mountable on For 3-pole contactors 3RA9 3-C front S3 S3 S3 S S3 0 mm Laterally mountable For 3-pole contactors For -pole contactors 3RA9 3-D 3RA9 -G 3RA9 -G Repeat coil terminal 3RA9 3-3B For Size Design Order No. Packing contactors Type set kg Sets 3RT0 3, 3RT0 S, S3 For coil terminals A and A for reversing starters of size S and S3 contactors. x A and x A are required per assembly. ( set contains 0 x A and x A) 3RA9 3-3B 0.0 ) This pack contains 0 additional interlocks. ) The connector function can be fulfilled with the wiring connectors for size S0, a contactor clearance of 0 mm and a lateral interlock. 3/ Only supplied in packings Siemens NS K 000

14 SIRIUS 3R 3RA Contactor Assemblies for Star-Delta Starting Accessories Installation kits Design Sizes Order No. Packing Mechanical interlock 3 connecting clips Connecting clips Star jumper on the top Wiring jumper on the bottom ) Star jumper on the top Wiring connector on the bottom ) Star jumper on the top Wiring jumper on the bottom ) Star jumper on the top Wiring jumper on the bottom ) set S00-S00-S00 3RA9 3-B 0.0 set set S0-S0-S0 3RA9 3-B 0.0 set set S-S-S0 3RA9 33-C 0. set set S-S-S 3RA9 33-B 0. set set S3-S3-S 3RA9 3-C 0.33 set set S3-S3-S3 3RA9 3-B 0. set kg 3-phase feeder terminal Feeder terminal block for the line contactor for large conductor cross-sections unit Conductor cross-section: mm S00 3RA9 3-3K units Conductor cross-section: mm S0 3RV9 -A 0.0 unit Conductor cross-section: 0 mm S 3RV9 3-A 0.0 unit 3-phase busbar For in-phase bridging of all input terminals of the unit line contactor (K) S0 3RV9 -A units and the delta contactor (K3) S 3RV9 3-A 0. 0 units Link for paralleling, 3-pole (star jumpers) 3RT9 -BA3 Without terminal (the links for paralleling can be reduced by one pole) unit S00 3RT9 -BA units S0 3RT9 -BA units S 3RT9 3-BA3 0.0 units S3 3RT9 -BA3 0.0 units Baseplates For customer assembly of star-delta contactor assemblies with a laterally mounted time-delay relay unit Side-by-side mounting S S S0 3RA9 3-E 0. unit S S S 0 mm clearance between K3 and K 3RA9 3-F 0.8 unit Side-by-side mounting S3 S3 S 3RA9 -E 0. unit For customer assembly of star-delta contactor assemblies with a front-mounted time-delay relay unit 0 mm clearance between K and K3 and K S S S0 3RA9 3-B 0. unit S S S F3RA9 3-B 0. unit S3 S3 S 3RA9 -B 0.0 unit ) The wiring connector on the top is not included in the scope of supply. A double infeed between the line contactor and the delta contactor is recommended. Siemens NS K 000 Only supplied in packings 3/3

Switching Devices Contactors and Contactor Assemblies Special Applications

Switching Devices Contactors and Contactor Assemblies Special Applications Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Low Voltage Controls & Distribution

Low Voltage Controls & Distribution SIRIUS Datasheet 2009 Low Voltage Controls & Distribution Answers for industry. s Pressing, equipping, transporting. These functions run in many automated production environments. You ll find everything

More information

Industrial Controls SIRIUS Controls

Industrial Controls SIRIUS Controls Industrial Controls SIRIS Controls Star-delta (Wye-delta) Switching of Three-phase Induction Motors Transient Current Peak Reduction using a Preferred Circuitry Configuration for Clockwise and Counterclockwise

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

3RV Motor Starter Protectors up to 100 A

3RV Motor Starter Protectors up to 100 A General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Siemens AG 2008. Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS. Answers for industry.

Siemens AG 2008. Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS. Answers for industry. Siemens AG 00 Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS Answers for industry. Siemens AG 00 Everything for the electrical cabinet: SIRIUS Modular System.

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2494434 (012730_C_000) Issued to: Siemens AG DF CP R&D V 3 Werner-von-Siemens-Strasse 48 Amberg, 92224 GERMANY Attention: Michael Schroeck The products listed below

More information

Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays

Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays Siemens AG 2013 Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays Price groups 41A, 41B, 41H, 4N1 /2 Introduction Contactor relays /4 SIRIUS 3RH2 contactor relays, 4- and

More information

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52 Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Controls Solid-State Switching Devices

Controls Solid-State Switching Devices Controls Solid-State Switching Devices Introduction Overview 3RF21 3RF20 3RF23 3RF29 SIRIUS SC solid-state switching devices Solid-state relays 22.5 mm solid-state relays, 5 mm solid-state relays Solid-state

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to

More information

SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01

SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Report Reference E156943-200906 Issued to: Siemens AG I IA CE CP R&D-VI 4 Werner-Von-Siemens-Strasse 48 92220 Amberg, Germany This is to certify that representative samples of Combination Motor Controllers

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Section 5. IEC Power Devices. www.geindustrial.com Control Catalog 5-1

Section 5. IEC Power Devices. www.geindustrial.com Control Catalog 5-1 Contactors Overview ()...5-3 Mini Contactors () Overview...5-4 Features and Benefits...5-5 Accessory Features...5-6 Product Offering...5-7 Product Number Selection Instructions...5-7 Product Descriptions...5-8

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

Plug-in relays Mini ISO relays

Plug-in relays Mini ISO relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8

More information

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives 3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Panorama. Motor protection and control Manual motor starters, contactors and overload relays

Panorama. Motor protection and control Manual motor starters, contactors and overload relays Panorama Motor protection and control Manual motor starters, contactors and overload relays ABB sets a new standard in motor control and power switching Featuring AF technology as standard, the latest

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

V REG.-Nr. 115719, Z E135149 Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

V REG.-Nr. 115719, Z E135149 Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays Accessories Miniature Relay PT Easy replacement of relays on a densely packed DIN rail No reduction of protection class or creepage/clearance with plastic retainer Plug-in indicator- and protection modules

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

General Purpose Relays Accessories. Accessories Miniature Relay PT

General Purpose Relays Accessories. Accessories Miniature Relay PT Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n

More information

IO-RM3 3-Stage Relay Module

IO-RM3 3-Stage Relay Module Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Residual Current Protective Devices

Residual Current Protective Devices Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting

More information

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) 4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

GAE953 Electrical Alarm Unit 19" with Indicator

GAE953 Electrical Alarm Unit 19 with Indicator Master Instruction 08.95 MI EIO2211 A-(en) GAE953 Electrical Alarm Unit 19" with Indicator The electrical alarm unit GAE953 gives a signal when one or two set alarm values have been exceeded. Input signals

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

SICOP. Low Voltage Control Components. www.siemens.co.in

SICOP. Low Voltage Control Components. www.siemens.co.in s SICOP Low Voltage Control Components Datasheet 205 www.siemens.co.in s Planning Efficiency Cx pplications Save Time. Save Money. vailable for: 3TF contactors 3U/3UC thermal overload relays 3VU MPCB Index

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

60 Series - General purpose relays 6-10 A. Features 60.12 60.13

60 Series - General purpose relays 6-10 A. Features 60.12 60.13 Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Motor suppressors. Standardized motor suppression from Murrelektronik

Motor suppressors. Standardized motor suppression from Murrelektronik Standardized motor suppression from Murrelektronik In the guideline EN 60204/DE 0113 para. 11.2.2 it states, that motors in PLC or NC controlled machines and systems must be fitted with a suitable suppressor.

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information