Loads and Seismic Design National Building Code Wind and Snow Importance Factors

Size: px
Start display at page:

Download "Loads and Seismic Design. 2005 National Building Code Wind and Snow Importance Factors"

Transcription

1 Loads and Seismic Design 2005 National Building Code Wind and Snow Importance Factors Russ Riffell, P.Eng. Chair, Standing Committee on Structural Design Part 4 of the National Building Code of Canada National Building Code of Canada Q What Is It? h Model Code that is essentially a set of provisions for the safety of the public in buildings zsafety zhealth zaccessibility z Fire and Structural Protection of Buildings h Intended for use throughout Canada zconsistent set of rules 1

2 National Building Code of Canada Q Where Does It Come From? h National Research Council publishes the NBC h All Canadians have input to it: zprovincial/territorial Policy Advisory Committee on Codes (PTPACC) zpublic Review z Membership in Committees National Building Code of Canada Q Under the Constitution Act, provincial and territorial governments regulate building Q PTPACC h Established by provincial and territorial code authorities to provide policy guidance to the NBC h Liaison with provinces/territories and the NBC h Intended to ensure relevance of the NBC Q NBC not law unless officially adopted by a territory or province or Vancouver or Montreal 2

3 National Building Code of Canada National Research Council Canadian Commission on Building and Fire Codes Provincial/Territorial Policy Advisory Committee on Codes (PTPACC) National Building Code of Canada Standing Committee on Structural Design (SCSD) Part 4 Structural Design CANCEE User s Guide Structural Commentaries NBC Q Objective-based Code h CCBFC declared a partial moratorium on code changes to allow standing committees to concentrate on conversion to objective-based format. h Part 4 not affected h Created delay in publishing of NBC Q Code objectives clearly defined Q Promote innovation Q Revisions easier to implement 3

4 2005 Code Format Q Two Divisions, A and B Q Division A h Compliance h Objectives h Functional Requirements Q Division B h Acceptable Solutions zpart 4 zother solutions with safety >= Part 4 Harmonizing Loads Q Wind (1995) h Annual probability of being exceeded z1/100 for strength of post-disaster buildings z1/30 for primary structural action z1/10 for cladding and deflection or vibration Q Earthquake (1995) h Probability of exceedance of 10% in 50 years h Annual probability of being exceeded z 1/475 4

5 Harmonizing Loads Q Earthquake (cont d) h Specified load includes a Seismic Importance Factor, I zi = 1.5 for post-disaster buildings zi = 1.3 for schools zi = 1.0 for all other buildings Q Snow (1995) 30 year return period, i.e.1/30 Harmonizing Loads Q SCSD established a task group to study this issue of different methods of accounting for loads h Earthquake includes a seismic importance factor h Wind varies the return period which is another method of implementing an importance factor h Account for buildings used for shelter in time of disaster h Review of loads, load factors and load combinations 5

6 Loads Q Dead Load, D h permanent load due to weight of building components (and vertical loads due to earth) Q Live Load, L h variable load due to intended use and occupancy, including loads due to cranes and pressure of liquids in containers Q H h permanent load due to lateral earth pressure, including groundwater Loads Q Snow Load, S h variable load due to snow + ice + included rain, or rain Q Wind Load, W h variable load Q Earthquake Load, E h rare load Q P and T h permanent load due to prestress h temperature, shrinkage, moisture, creep, settlement 6

7 Limit States Design Q Ultimate Limit States Limit state just satisfied Limit States Design Q Statistical Analysis of Safety 7

8 Limit States Design Q Statistical analysis of safety Let X = ln R/S V x = standard deviation of X Set distance from 0 to the mean value as E times V x. Thus, E is the reliability index. Reliability Index Q 1995 Code examined to calibrate new loads (return periods) and load factors. h Live load that includes both use and occupancy and snow load is conservative h Reliability indices for the combination of dead load and snow load are smaller than other load combinations. OK for concrete but not for steel or timber. h Combination of dead, wind and snow for steel: reliability index > 3, except where snow load dominates 8

9 Reliability Index & Load Factors Q 2005 h Combinations of dead and live (use & occupancy) and dead and wind loads from the 1995 NBCC have 50- year reliability indices of 3.0 or larger. h Return period of 50 years h Target Reliability Index of 3.0 Wind Load Calibration Q Canadian Meteorological Society has 223 sites with records for at least 10 years. Q Data analyzed by fitting a Gumbel distribution to wind velocities. Q 50 and 500 year return period values calculated from this distribution. Q Importance values calculated from distribution. h Mean value for 100 year return period is

10 Wind Load Calibration in-10 1-in-50 1-in in mean 90% of values in this range COV of Maximum Annual Wind Velocity Wind Loads Q Exposure factor, Ce h Two conditions: zopen Terrain - level with scattered buildings, trees or other obstructions, shoreline, open water. (Same as 1995.) zrough Terrain - suburban, urban or wooded for at least 1 km or 10 x the building height. Q Gust Effect Factor for Internal Pressures, Cgi h Was 1.0 to 2.0. Now 2.0 unless a detailed calculation yields a lower value. 10

11 Wind Reference Pressure Reference Velocity Pressure (kpa) Location 1-in-10 1-in-30 1-in-50 1-in in-500 Victoria (Gonzales) Winnipeg Mississauga Halifax Wind Reference Pressure Design Wind Velocity Pressures, q 30 and q 50 City q 30 (q 50 ), kpa Victoria 0.58(0.63) Vancouver 0.44(0.48) Chilliwack 0.63(0.72) Kamloops 0.37(0.40) Kelowna 0.43(0.47) Revelstoke 0.29(0.32) Calgary 0.46(0.50) Edmonton 0.40(0.45) 11

12 Internal Pressures Q Category 1 (small, uniformly distributed openings) h 1995 Cpi = 0.0 to -0.3; Cg = 1.0 h 2005 Cpi = 0.0 to -0.15; Cgi = 2.0 or calculated Q Category 2 (significant openings will be closed) h 1995 Cpi = 0.7 to -0.7; Cg = 1.0 h 2005 Cpi = 0.3 to -0.45; Cgi = 2.0 or calculated Q Category 3 (gusts transmitted to interior) h 1995 Cpi = 0.7 to -0.7; Cg = 2.0 h 2005 Cpi = 0.7 to -0.7; Cgi = 2.0 or calculated Wind Loads Q Cgi Detailed Calculation h Cgi = 1 + 1/(1 + τ/10)^1/2 h τ = Vo/(695 x A) x ( * As/Vo * δ) zvo = internal volume (m 3 ) za = total area of all openings in the envelope (m 2 ) zas = total exterior surface area (m 2 ) zδ = the average flexibility of walls and roof, and is equal to the interior volume change in m 3 per kpa of pressure change divided by the total surface area in m 2 of slabs and walls excluding slabs on grade 12

13 Wind Load Comparison Fig. 1: Code Loads - 4 sq.m. of Edge Wall Cladding - Open Terrain Wind Load, kpa NBC2005 qaverage NBC1995 qaverage ASCE 2002 NBC2005 qtoronto NBC1995 qtoronto Building Height, m Wind Load Comparison 4.0 Fig. 2: Code Loads - 4 sq.m of Edge Wall Cladding - Rough Terrain Wind Load, kpa NBC2005 qaverage NBC1995 qaverage ASCE 2002 NBC2005 qtoronto NBC1995 qtoronto Building Height, m 13

14 Wind Load Comparison Fig. 3: Code Loads - 4 sq.m. of Mid-Wall Cladding - Open Terrain Wind Load, kpa NBC 2005 NBC 1995 ASCE 2002 NBC2005 qtoronto 0.5 NBC1995 qtoronto Building Height, m Wind Load Comparison Fig. 4: Code Loads - 4 sq.m. of Mid-Wall Cladding - Rough Terrain Wind Load, kpa NBC 2005 NBC ASCE NBC2005 qtoronto NBC1995 qtoronto Building Height, m 14

15 Wind Load Comparison Fig. 5: Code Loads - Structure (Across Building) - Open Terrain Wind Load, kpa NBC2005 qaverage NBC1995 qaverage ASCE 2002 NBC2005 qtoronto NBC1995 qtoronto Building Height, m Wind Load Comparison 2.5 Fig. 6: Code Loads - Structure (Across Building) - Rough Terrain 2.0 Wind Load, kpa NBC2005 qaverage NBC1995 qaverage ASCE 2002 NBC2005 qtorontor NBC1995 qtoronto Building Height, m 15

16 Wind Load Comparison 2.5 Fig. 7: Code Loads - Structure (Along Building) - Open Terrain 2.0 Wind Load, kpa NBC2005 qaverage NBC1995 qaverage ASCE 2002 NBC2005 qtoronto NBC1995 qtoronto Building Height, m Wind Load Comparison Fig. 8: Code Loads - Structure (Along Building) - Rough Terrain Wind Load, kpa NBC2005 qaverage NBC1995 qaverage ASCE 2002 NBC2005 qtoronto NBC1995 qtoronto Building Height, m 16

17 Wind Design Flow Chart q: NBC Appendix C Structural components and Cladding Building structure (1,2) H>120 m Yes No (1,2) Yes H/w>4 No (2) Susceptible to vibrations Yes Static Procedure No Static Procedure Dynamic Procedure (3) Ce: NBC (5) Par. 7-8, Ce: NBC (5) Par. 7, Ce: Par. 7, High-Rise Cg: 2.5 Par No (1) H 20 m (1) High-Rise H 20 m and No Cg: 2.0 H/D < 1 Par Cg: Par Yes Yes Cp*: Par , 29, Fig. I-10 (4) CgCp: Par , 25-28, Fig. I-4 to I-9 (4) CgCp: Par , 25-28, Fig. I-3 (4) Cp: Par , 29, Fig. I-10 (4) Cp: Par , Fig. I-10 (4) Internal pressure Cgi: 2.0 or Par. 22 Cpi: Par pe (5) = IwqCeCgCp pe (5) = IwqCeCgCp pe (5) = IwqCeCgCp Notes: pe = IwqCeCgCp and pi = IwqCeCgiCpi Partial Loading: Par , Fig. I-11 Partial Loading: Par , Fig. I-11 Reliability Index & Load Factors Q Snow h Large variability in load h New calibration gave load factor = 1.7 zfactored snow load would increase by 25% h Decided to remain with LF = 1.5 zfactored snow load now ~ 10% larger than

18 Reliability Index Q 1995 Code h Reliability indices for the combination of dead load and snow load are smaller than other load combinations. OK for concrete but not for steel or timber. h Combination of dead, wind and snow for steel: reliability index > 3, except where snow load dominates Snow Q Reduction of wind exposure factor, Cw, tightened. Cannot reduce from 1.0 for Importance categories High and Post-Disaster. Q Drift criteria for curved roofs 18

19 Importance Factors Q Apply an importance factor to all variable loads, based on use and occupancy Q Use and Occupancy h Low Hazard h All Others h Emergency Shelter h Post-Disaster Q Importance Category h Low h Normal h High h Post-Disaster Importance Factor - Wind Importance Category I W ULS SLS Low Normal High Post Disaster

20 Importance Factor - Snow Importance Category I s ULS SLS Low Normal High Post Disaster Major Changes to Part 4 Q Harmonization of Return Periods and Importance Factors h Review of reliability index for factored loads and resistances Q Companion Action Load Combinations h Re-definition of loads, factors & combinations Q 50 year return periods for Wind and Snow Q Revised Seismic Design Requirements 20

21 Other Changes Q WSD gone h Masonry standard now only LSD, no WSD h Factored resistance of soil for design of foundations - no more allowable bearing pressures Q Steel building systems added to 4.3 Factored Loads 2005 vs Q Dead + Live combination is unchanged. Q Dead + Wind combination 1% less than Q Dead + Snow combination 10% greater than Q Dead + Live + Snow combination less than Q Dead+ Live + Wind greater than Q Dead + Wind + Snow greater than

22 Questions 22

Loads and Load Combinations for NBCC. Outline

Loads and Load Combinations for NBCC. Outline Loads and Load Combinations for NBCC Prepared by Dr Michael Bartlett, P.Eng University of Western Ontario Presented with minor modifications by Dr Robert Sexsmith, P.Eng. University of British Columbia

More information

National Building Code of Canada 2010

National Building Code of Canada 2010 National Building Code of Canada 2010 Emergency Change Issued by the Canadian Commission on Building and Fire Codes The table that follows lists two emergency changes that apply to the National Building

More information

Executive Summary Inclusion of Current Firewall Requirements in NBCC

Executive Summary Inclusion of Current Firewall Requirements in NBCC Executive Summary Inclusion of Current Firewall Requirements in NBCC This background paper has been prepared on behalf of the Gypsum Manufacturers of Canada by Standing Committee on Fire Safety & Occupancy

More information

EUROCODE 1 Actions on Building Structures

EUROCODE 1 Actions on Building Structures EU-Russia cooperation on standardisation for construction Moscow, 9-10 October 2008 1 EUROCODE 1 Actions on Building Structures Paolo Formichi CEN/TC250/SC1 University of Pisa (Italy) EU-Russia cooperation

More information

CH. 2 LOADS ON BUILDINGS

CH. 2 LOADS ON BUILDINGS CH. 2 LOADS ON BUILDINGS GRAVITY LOADS Dead loads Vertical loads due to weight of building and any permanent equipment Dead loads of structural elements cannot be readily determined b/c weight depends

More information

Load and Resistance Factor Geotechnical Design Code Development in Canada. by Gordon A. Fenton Dalhousie University, Halifax, Canada

Load and Resistance Factor Geotechnical Design Code Development in Canada. by Gordon A. Fenton Dalhousie University, Halifax, Canada Load and Resistance Factor Geotechnical Design Code Development in Canada by Gordon A. Fenton Dalhousie University, Halifax, Canada 1 Overview 1. Past: Where we ve been allowable stress design partial

More information

determining wind and snow loads for solar panels America s Authority on Solar

determining wind and snow loads for solar panels America s Authority on Solar determining wind and snow loads for solar panels America s Authority on Solar Determining wind and snow loads for solar panels 1 introduction As one of the largest and most established vertically integrated

More information

Basics of Reinforced Concrete Design

Basics of Reinforced Concrete Design Basics of Reinforced Concrete Design Presented by: Ronald Thornton, P.E. Define several terms related to reinforced concrete design Learn the basic theory behind structural analysis and reinforced concrete

More information

Computer Program for the Analysis of Loads On Buildings. Using the ASCE 7-93 Standard. Stephen E. Browning. Master of Engineering.

Computer Program for the Analysis of Loads On Buildings. Using the ASCE 7-93 Standard. Stephen E. Browning. Master of Engineering. Computer Program for the Analysis of Loads On Buildings Using the ASCE 7-93 Standard Minimum Design Loads for Buildings and Other Structures by Stephen E. Browning Report submitted to the Faculty of Virginia

More information

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)

More information

ARCHITECTURE. Asst. Prof. Meltem VATAN KAPTAN [email protected]

ARCHITECTURE. Asst. Prof. Meltem VATAN KAPTAN meltemvatan@aydin.edu.tr STRUCTURES IN ARCHITECTURE Asst. Prof. Meltem VATAN KAPTAN [email protected] Istanbul Aydin University, Faculty of Engineering and Architecture ISTANBUL, TURKEY December 15, 2011 - GAZIANTEP If

More information

Thermal Bridging of Masonry Veneer Claddings and Energy Code Compliance

Thermal Bridging of Masonry Veneer Claddings and Energy Code Compliance Thermal Bridging of Masonry Veneer Claddings and Energy Code Compliance! Graham Finch, MASc, P.Eng Mike Wilson, MEng, P.Eng James Higgins, Dipl.T RDH Building Engineering Ltd. Vancouver, BC June 3, 2013

More information

FOUNDATION TECHNICAL CATEGORY 3 (TC3) AUGUST 2012

FOUNDATION TECHNICAL CATEGORY 3 (TC3) AUGUST 2012 FOUNDATION TECHNICAL CATEGORY 3 (TC3) AUGUST 2012 Building and Housing has published technical guidance for foundation repairs and reconstruction for residential properties in green zone Foundation Technical

More information

Development of Seismic-induced Fire Risk Assessment Method for a Building

Development of Seismic-induced Fire Risk Assessment Method for a Building Development of Seismic-induced Fire Risk Assessment Method for a Building AI SEKIZAWA National Research Institute of Fire and Disaster 3-14-1, Nakahara, Mitaka, Tokyo 181-8633, Japan [email protected]

More information

Professional Engineers Providing Structural Engineering Services In Buildings

Professional Engineers Providing Structural Engineering Services In Buildings GUIDELINE Professional Engineers Providing Structural Engineering Services In Buildings 1995 Published by Association of Professional Engineers of Ontario Revised 12/11/98 CONTENTS INTRODUCTION...3 PART

More information

How To Control Water Penetration In A Window

How To Control Water Penetration In A Window WATER PENETRATION CONTROL FOR WINDOWS A SERVICE LIFE APPROACH David R. Ricketts, P.Eng. 1 and Silvio Plescia, P.Eng. 2 INTRODUCTION Building envelope performance problems and their close link to poor window

More information

6 RETROFITTING POST & PIER HOUSES

6 RETROFITTING POST & PIER HOUSES Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This

More information

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN CHAPTER Structural Steel Design LRFD Method Third Edition SPECIFICATIONS, LOADS, AND METHODS OF DESIGN A. J. Clark School of Engineering Department of Civil and Environmental Engineering Part II Structural

More information

Commercial Building Valuation Report

Commercial Building Valuation Report INSURED University of Houston - Victoria Effective Date: Expiration Date: Cost as of: 09/2010 BUILDING 1 217 - University Center 77901 Location Adjustments Climatic Region: High Wind Region: Seismic Zone:

More information

Residential Sheltering: In-Residence and Stand-Alone Shelters

Residential Sheltering: In-Residence and Stand-Alone Shelters Residential Sheltering: In-Residence and Stand-Alone Shelters Intended Audience and Purpose The purpose of this Tornado Recovery Advisory (RA) is to alert homeowners, renters, and apartment building owners

More information

EN 1991-1-6 DK NA:2007

EN 1991-1-6 DK NA:2007 EN 1991-1-6 DK NA:2007 National Annex to Eurocode 1: Actions on structures - Part 1-6: General actions Actions during execution Foreword In connection with the incorporation of Eurocodes into Danish building

More information

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems: Reading Assignment SLAB DESIGN Chapter 9 of Text and, Chapter 13 of ACI318-02 Introduction ACI318 Code provides two design procedures for slab systems: 13.6.1 Direct Design Method (DDM) For slab systems

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies

ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies Approved September 19, 2007 ANSI/SPRI WD-1 ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies TABLE OF CONTENTS Section Page 1.0 INTRODUCTION...........................................................

More information

WORLD S TALLEST TIMBER BUILDING, BERGEN

WORLD S TALLEST TIMBER BUILDING, BERGEN WORLD S TALLEST TIMBER BUILDING, BERGEN Trondheim, Norway. 2014-09-26 M. Sc. Rune B Abrahamsen, Sweco, Lillehammer, Norway Bergen- og omegn boligbyggelag (BOB) is a Norwegian housing association. They

More information

Page & Turnbull imagining change in historic environments through design, research, and technology

Page & Turnbull imagining change in historic environments through design, research, and technology DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED

More information

4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections. Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls

More information

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.) APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL FIRE RESTORATION PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of

More information

Wind Speed Maps for the Caribbean for Application with the Wind Load Provisions of ASCE 7

Wind Speed Maps for the Caribbean for Application with the Wind Load Provisions of ASCE 7 Wind Speed Maps for the Caribbean for Application with the Wind Load Provisions of ASCE 7 Prepared by P. J. Vickery and D. Wadhera Applied Research Associates, Inc. 8540 Colonnade Centre Drive, Suite 307

More information

MacroFlo Opening Types User Guide <Virtual Environment> 6.0

MacroFlo Opening Types User Guide <Virtual Environment> 6.0 MacroFlo Opening Types User Guide 6.0 Page 1 of 18 Contents 1. Introduction...4 2. What Are Opening Types?...5 3. MacroFlo Opening Types Manager Interface...5 3.1. Add... 5 3.2. Reference

More information

Firewalls. By Gary Sturgeon, B.Eng., MSc., P.Eng. Technical Services Engineer, CCMPA. w w w. c c m p a. c a 5A-0

Firewalls. By Gary Sturgeon, B.Eng., MSc., P.Eng. Technical Services Engineer, CCMPA. w w w. c c m p a. c a 5A-0 By Gary Sturgeon, B.Eng., MSc., P.Eng. Technical Services Engineer, CCMPA 5A-0 This Chapter of the CCMPA Metric Technical Manual has been largely reproduced from Firewalls, A Design Guide, published by

More information

Advanced FBC: Changes to the Wind Load Provisions of the 2010 Florida Building Code and ASCE 7-10

Advanced FBC: Changes to the Wind Load Provisions of the 2010 Florida Building Code and ASCE 7-10 Advanced FBC: Changes to the Wind Load Provisions of the 2010 Florida Building Code and ASCE 7-10 presented by T. Eric Stafford T. Eric Stafford & Associates, LLC This material is protected and the property

More information

Seismic Risk Prioritization of RC Public Buildings

Seismic Risk Prioritization of RC Public Buildings Seismic Risk Prioritization of RC Public Buildings In Turkey H. Sucuoğlu & A. Yakut Middle East Technical University, Ankara, Turkey J. Kubin & A. Özmen Prota Inc, Ankara, Turkey SUMMARY Over the past

More information

C&D Waste Diversion in Other Jurisdictions. Maria Kelleher 20 th July, 2006

C&D Waste Diversion in Other Jurisdictions. Maria Kelleher 20 th July, 2006 C&D Waste Diversion in Other Jurisdictions Maria Kelleher 20 th July, 2006 Best Practices Research to look at what others are doing is underway Focus on active drivers not passive ones, such as voluntary

More information

research highlight Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification

research highlight Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification research highlight November 2003 Technical Series 03-125 Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification introduction Over the past decade, there has been

More information

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure

More information

The Florida Building Code

The Florida Building Code Setting New Standards for Safety The Florida Building Code Florida Building Commission Florida Department of Community Affairs The Florida Building Code System The Florida Building Commission Florida Building

More information

Eurocodes Background and Applications

Eurocodes Background and Applications Eurocodes Background and Applications Eurocode example: Actions on a six storey building 18-2 February 28 Prepared by: Kirstine Bak-Kristensen vend Ole Hansen 2 TABLE OF CONTENT 1. ntroduction... 3 2.

More information

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline

More information

How To Design A Post Tensioned Deck For A Building

How To Design A Post Tensioned Deck For A Building SAMUEL ÁVILA STRUCTURAL OPTION FACULTY CONSULTANT: THOMAS BOOTHBY UNIVERSITY OF CENTRAL FLORIDA S ACADEMIC VILLAGES ORLANDO, FL THESIS PROPOSAL EXECUTIVE SUMMARY DECEMBER 12, 2005 Introduction: The University

More information

Seismic performance evaluation of an existing school building in Turkey

Seismic performance evaluation of an existing school building in Turkey CHALLENGE JOURNAL OF STRUCTURAL MECHANICS 1 (4) (2015) 161 167 Seismic performance evaluation of an existing school building in Turkey Hüseyin Bilgin * Department of Civil Engineering, Epoka University,

More information

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings Best2 Airtightness of Buildings Session WB6-2 Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings Mario D. Gonçalves, Patenaude-Trempe and Robert Jutras, Air-Ins Introduction

More information

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Introduction...COMB-2 Design Considerations and Examples...COMB-3 SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant

More information

INTRODUCTION TO LIMIT STATES

INTRODUCTION TO LIMIT STATES 4 INTRODUCTION TO LIMIT STATES 1.0 INTRODUCTION A Civil Engineering Designer has to ensure that the structures and facilities he designs are (i) fit for their purpose (ii) safe and (iii) economical and

More information

EARTHQUAKE DESIGN OF BUILDINGS

EARTHQUAKE DESIGN OF BUILDINGS GAP.2.0.9 A Publication of Global Asset Protection Services LLC EARTHQUAKE DESIGN OF BUILDINGS INTRODUCTION Buildings in many areas of the world are susceptible to damage from moderate to severe earthquakes.

More information

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver Designing an Effective Envelope Roofs Below Grade Walls and slabs Glazing & Windows Opaque portions of walls 2 3 Energy

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

[TECHNICAL REPORT I:]

[TECHNICAL REPORT I:] [Helios Plaza] Houston, Texas Structural Option Adviser: Dr. Linda Hanagan [TECHNICAL REPORT I:] Structural Concepts & Existing Conditions Table of Contents Executive Summary... 2 Introduction... 3 Structural

More information

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California 94103. Prepared By

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California 94103. Prepared By Project Structural Conditions Survey and Seismic Vulnerability Assessment For SFCC Civic Center Campus 750 Eddy Street San Francisco, California 94109 Prepared For San Francisco Community College District

More information

Commercial Building Valuation Report

Commercial Building Valuation Report INSURED State Office of Risk Management Effective Date: 300 W 15th Street Expiration Date: Austin, TX 78701 Cost as of: 12/2013 BUILDING 1 Athletics/PCI - 206 3302 N. Ben Wilson Victoria, TX 77901 Location

More information

Commercial Residential Model Reviews

Commercial Residential Model Reviews Commercial Residential Model Reviews Prepared by the Professional Team for The Florida Commission on Hurricane Loss Projection Methodology May 2002 I. Background and Items for Consideration In May, 2000,

More information

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the

More information

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures Prof. Oral Buyukozturk Massachusetts Institute of Technology Outline 1 1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

Repair of Spalling and Leaking Clay Brick Building Walls

Repair of Spalling and Leaking Clay Brick Building Walls B etter buildings Repair of Spalling and Leaking Clay Brick Building Walls Overview A few years after being built in Waterloo in 1980, a condominium of three, six-storey buildings showed severe spalling

More information

Soils, Foundations & Moisture Control

Soils, Foundations & Moisture Control Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations

More information

Fire Alarm And System Description. Automatic Sprinkler System Description. Fire Suppression Equipment. Fire and Evacuation Drills

Fire Alarm And System Description. Automatic Sprinkler System Description. Fire Suppression Equipment. Fire and Evacuation Drills Building Name: Maddox Hall Year Built: 1985 Occupancy: Residence Hall Capacity: 152 Construction Type: Reinforced concrete slab, CMU walls, flat roof concrete slab. Building Name: Wright Hall Year Built:

More information

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide

More information

HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 [email protected]

HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 office@heddermanengineering.com HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 [email protected], 2011 TO: Mr. REF: CONDITION OF PROPERTY SURVEY Dear Mr. : At your request,

More information

Dynamic Wind Testing of Commercial Roofing Systems

Dynamic Wind Testing of Commercial Roofing Systems Construction Technology Update No. 55 Dynamic Wind Testing of Commercial Roofing Systems by A. Baskaran Single-ply roofs (SPRs) behave differently than built-up roofs and a simple test method is needed

More information

Certification: Building Plans Examiner. Exam ID: B3

Certification: Building Plans Examiner. Exam ID: B3 Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building

More information

EN 1991-1-4:2005. Wind actions

EN 1991-1-4:2005. Wind actions EN 1991 Eurocode 1: Actions on structures Your logo Brussels, 18-20 February 2008 Dissemination of information workshop 1 EN 1991-1-4:2005 Wind actions EN 1991-1-4:2005 Contents Brussels, 18-20 February

More information

Code of Standard Practice for Timber Frame Structures

Code of Standard Practice for Timber Frame Structures TFEC 2-2013 Code of Standard Practice for Timber Frame Structures August 2013 Preface This Code is intended to represent a reasonable consensus of what constitutes ordinary and acceptable practice within

More information

Marketing Coordinator Bootcamp Session 2: ABCs of AEC

Marketing Coordinator Bootcamp Session 2: ABCs of AEC Marketing Coordinator Bootcamp Session 2: ABCs of AEC Debbie Chen, LEED AP, APMP CF Proposal Development Director Louis Berger [email protected] Matthew Daw, PE, LEED AP Principal Keast & Hood [email protected]

More information

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA STRUCTURAL ASSESSMENT FOR Full Metal Jacket Building 0 Prince Street, Prepared by: ALPHA CORPORATION (Alpha) 1850 S. Loudoun Street, Suite 200 Winchester, VA 22601 540-723-0704 September 22, 2010 J. Michael

More information

COMMONLY USED RESIDENTIAL BUILDING CODES

COMMONLY USED RESIDENTIAL BUILDING CODES COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section

More information

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS 8601 North Black Canyon Highway Suite 103 Phoenix, AZ 8501 For Professionals Engaged in Post-Tensioning Design Issue 14 December 004 DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS by James D. Rogers 1 1.0

More information

Structural Analysis. EUROCODE 2 Background and Applications

Structural Analysis. EUROCODE 2 Background and Applications Dissemination of information for training Brussels, 20-21 October 2011 1 Prof. Dr.-Ing. Manfred Curbach TU Dresden, Institute for Concrete Structures M.Sc. Martin Just TU Dresden, Institute for Concrete

More information

HOW METAL BUILDING INSURANCE COSTS COMPARE TO OTHER BUILDING TYPES

HOW METAL BUILDING INSURANCE COSTS COMPARE TO OTHER BUILDING TYPES MBMA INSURANCE BULLETIN no. 15 HOW METAL BUILDING INSURANCE COSTS COMPARE TO OTHER BUILDING TYPES Contractors who build with other products will compete with metal buildings based on an assumption that

More information

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3 TOWN OF SIDNEY Multi-Family, Commercial, Industrial and Institutional Building Permit Guide The information provided is intended as a guide only and does not replace current bylaws and regulations. Complete

More information

Wind-Resistive Design of Wood Buildings

Wind-Resistive Design of Wood Buildings Wind-Resistive Design of Wood Buildings Wood is a proven choice for wind-resistive construction Sponsored by rethink Wood and the American Wood Council By Jeffrey B. Stone, Ph.D. M ost regions of the United

More information

First 14-storey wood building in the world at Bergen in Norway Premier bâtiment en bois à 14 niveaux au monde à Bergen en Norvège

First 14-storey wood building in the world at Bergen in Norway Premier bâtiment en bois à 14 niveaux au monde à Bergen en Norvège First 14-storey wood building in the world at Bergen in Norway R. B. Abrahamsen 1 First 14-storey wood building in the world at Bergen in Norway Premier bâtiment en bois à 14 niveaux au monde à Bergen

More information

Reinforced Concrete Design

Reinforced Concrete Design FALL 2013 C C Reinforced Concrete Design CIVL 4135 ii 1 Chapter 1. Introduction 1.1. Reading Assignment Chapter 1 Sections 1.1 through 1.8 of text. 1.2. Introduction In the design and analysis of reinforced

More information

SECTION 3 ONM & J STRUCTURAL ANALYSIS

SECTION 3 ONM & J STRUCTURAL ANALYSIS Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION

More information

14 September 2015. Sarah Zorn Planning and Economic Development 25 West Fourth Street, Ste. 1100 St. Paul, MN 55102

14 September 2015. Sarah Zorn Planning and Economic Development 25 West Fourth Street, Ste. 1100 St. Paul, MN 55102 Sarah Zorn Planning and Economic Development 25 West Fourth Street, Ste. 1100 St. Paul, MN 55102 Project No.: 15538.00 Re: Structural Condition Review of the building at 700 4 th St. E. Dear Sarah: We

More information

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF... Building Insulations - Walls and Ceilings (FM Approval Numbers 4411, 4651, 4880, 4881, 4882) Insulating materials may occur in building construction to reduce heat or sound transmission through a wall,

More information

Building Condition Assessment: 109-111 North Howard Street Baltimore, Maryland

Building Condition Assessment: 109-111 North Howard Street Baltimore, Maryland KPA The Joint Venture of EBA Engineering, Inc. and Kennedy Porter & Associates, Inc. 4813 Seton Drive, Baltimore, MD 21215 Phone: (410-358-7171) Fax: (410)358-7213 Building Condition Assessment: Baltimore,

More information

Introduction. Eurocodes. Specification. Cost

Introduction. Eurocodes. Specification. Cost Introduction Eurocodes Specification Cost Structural Eurocodes BS EN 1990 (EC0): BS EN 1991 (EC1): Basis of structural design Actions on Structures BS EN 1992 (EC2): BS EN 1993 (EC3): BS EN 1994 (EC4):

More information

SEISMIC RETROFITTING OF STRUCTURES

SEISMIC RETROFITTING OF STRUCTURES SEISMIC RETROFITTING OF STRUCTURES RANJITH DISSANAYAKE DEPT. OF CIVIL ENGINEERING, FACULTY OF ENGINEERING, UNIVERSITY OF PERADENIYA, SRI LANKA ABSTRACT Many existing reinforced concrete structures in present

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

Elevating Your House. Introduction CHAPTER 5

Elevating Your House. Introduction CHAPTER 5 CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,

More information

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane

More information

How To Build A Two Hour Firewall In Calgary

How To Build A Two Hour Firewall In Calgary BUILDING CODE INTERPRETATION February 2008 06-BCI-005-R1 Page 1 of 6 TWO-HOUR FIREWALLS BACKGROUND Historically, firewalls used to subdivide buildings into smaller units have been built using one of two

More information

LAYING BLOCK AND BRICK

LAYING BLOCK AND BRICK LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct

More information

RESIDENTIAL COURSE OF CONSTRUCTION QUESTIONNAIRE

RESIDENTIAL COURSE OF CONSTRUCTION QUESTIONNAIRE RESIDENTIAL COURSE OF CONSTRUCTION QUESTIONNAIRE Residential Course of Construction policies, also known as Builder s Risk, are designed to cover the property owner for potential loss while the property

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report ESR-2369 Reissued May 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction

More information

Comparison of the Structural Provisions in the International Existing Building Code 2012 versus the Rhode Island State Rehabilitation Code

Comparison of the Structural Provisions in the International Existing Building Code 2012 versus the Rhode Island State Rehabilitation Code August 3, 2012 Existing Building Code 2012 versus the Rhode Island State By: Structural Engineers Association of Rhode Island, Building Code Committee Introduction At the request of the Building Code Standards

More information

Brock Commons Phase 1 University of British Columbia, Vancouver, Canada

Brock Commons Phase 1 University of British Columbia, Vancouver, Canada Construction Underway on World s Tallest Timber Tower Construction of the 18 storey Brock Commons Student Residence at the University of British Columbia in Vancouver, Canada got underway in November 2015.

More information

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE To satisfy the performance goals of the NEHRP Recommended Seismic Provisions, a number of characteristics are important to the

More information

World Tower. Company, Inc. Classification Overview. Categories: Structure Classification Exposure Categories Topographic Effects Geological

World Tower. Company, Inc. Classification Overview. Categories: Structure Classification Exposure Categories Topographic Effects Geological Manufacturing Custom Fabricated Structures since 1979 Professional In-House Design Staff Tower Delivery Service World Tower Company, Inc. Classification Overview Categories: Structure Classification Exposure

More information

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety

More information

Dollars & Sense of Compliance!

Dollars & Sense of Compliance! CRCA s 29 th Annual Trade Show Oakbrook k Terrace, IL January 19 20, 2012 Dollars & Sense of Compliance! Mark S. Graham Associate ExecutiveDirector Director, Technical Services National Roofing Contractors

More information

LP OSB Sheathing & Structural 1 Sheathing

LP OSB Sheathing & Structural 1 Sheathing Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48

More information

Structural Analysis of the Sutong Bridge Dorian Janjic

Structural Analysis of the Sutong Bridge Dorian Janjic Structural Analysis of the Sutong Bridge Dorian Janjic Summary The SuTong cable-stayed bridge is the Primary Fairway Bridge of the Suzhou-Nantong Yangtze River Bridge Project. It will be the most important

More information

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County Building Permit Application Packet The purpose of Building Codes is to establish the minimum requirements to safe guard the public health, safety and general welfare through structural strength, means

More information

9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards. Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and

More information

Overview How BC teacher salaries rank among the provinces and territories in 2011

Overview How BC teacher salaries rank among the provinces and territories in 2011 13 BARGAINING PROPOSAL BRITISH COLUMBIA TEACHERS FEDERATION Document Number: U102 Date: Time: Overview How BC teacher salaries rank among the provinces and territories in 2011 Minimum The minimum salary

More information

National Retail Report Canada FALL 2015 EDITION. Accelerating success.

National Retail Report Canada FALL 2015 EDITION. Accelerating success. National Retail Report Canada FALL 2015 EDITION Accelerating success. Report prepared by Colliers International Consulting James Smerdon Vice President and Director, Retail Consulting DIRECT +1 604 685

More information