VALERO IMAGE PAINT PROGRAM

Size: px
Start display at page:

Download "VALERO IMAGE PAINT PROGRAM"

Transcription

1 CORPORATE SERVICE STATION PAINTING SPECIFICATIONS VALERO IMAGE PAINT PROGRAM Revised November, 2006 MAINTENANCE / RENOVATIONS / NEW CONSTRUCTION - PRIMERS, URETHANES & ACRYLIC COATINGS - WOOD SEALERS AND STAINS - CONCRETE STAIN FOR ADA RAMPS - PARKING LOT STRIPING FOR CONCRETE AND ASPHALT SURFACES - CAR WASH - INTERIOR FINISHES NOTE: ALL PRODUCTS LISTED ARE APPROVED FOR ALL AREAS EXCEPT FOR THE SPECIFIC PRIMER AND URETHANE AND WOOD STAINS APPROVED FOR CALIFORNIA ALL SPECIFICATION ARE TO BE USED IN CONJUNCTIONS WITH PLANS PROVIDED FOR RENOVATIONS AND NEW CONSTRUCTION JONES-BLAIR PAINTS ARE THE APPROVED PAINTS FOR THIS PROGRAM. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT WRITTEN APPROVAL FROM THE DIRECTOR OF CONSTRUCTION

2 Revision Date: (November, 2006) CONTENTS ITEM PAGE 2.1 BUILDING EXTERIOR CMU / EIFS / METAL Textured FASCIA. 5 PVC Accent Bands on Marquee Steel Building Form (if applicable) Steel Dispenser Island Forms Steel light pole, steel bases and concrete bases. 6 Existing painted poles and steel bases Dumpster Enclosure new and existing Canopy Columns Canopy Fascia Canopy Deck / Building Soffits ID / Price Sign Poles Pipe Bollards Hand Rails Building Flashing / Standing Seam Electrical Panels Exterior H.V.A.C. Housing, Compressor Housing Equipment Screens Fuel Vents and brackets Street Boxes / Manhole Covers

3 2.2 BUILDING INTERIOR CMU all areas Drywall all areas Door and frames interior Store front frame and Entry Doors Exposed surfaces of walk-in coolers Restroom Interior Painting over ceramic wall tile CARWASH Exterior Building Fascia Pipe bollards Exterior and interior Electrical Panels Exterior Mechanical Rooms, Door / frame / Header Storerooms, Door / Frame / Header Restrooms, Door / Frame / Header Bay Door / Frame /Header Exterior Fan Covers

4 2.4 CARWASH Interior Restroom CMU BAY CMU -- OPTIONAL FINISHES. 17 OPTION 1 Painting existing Car Wash Buildings without removing the existing carwash equipment. OPTION 2 -- Fiberglass Panels for existing Car Wash Buildings To be used when replacing existing car wash equipment. OPTION 3 -- Fiberglass coating for new Car Wash Buildings For New To Industry Sites Bay Conduits / J-boxes Roof Downspout and wall Hangers Paving striping and Ramp Stains Wood Trellis Exterior Ice Merchandiser 19 4

5 2.1 BUILDING EXTERIOR 2.0 COATINGS SPECIFICATIONS CMU / EIFS / METAL Textured FASCIA PVC Accent Bands on Marquee Surface Preparation: Remove all loose mortar by rubbing surface with masonry block or scrape with 6 to 8 floor scraper to remove any mortar fins or protrusions. Remove all loose foreign matter with a stiff broom and coat before contamination occurs. CMU refers to Split face and fluted block. Jones-Blair #3781 Acrylic Latex Block mils dft/to fill completely. Top coat: Top coat: For Metal textured Fascia Jones-Blair Acrylithane C-HS Acrylic Urethane Topcoat. Two coats required applied at mils dft per coat. Color: JB # Valero Gray For Brick Veneer Jones-Blair Primer #3090 Multi-Grip 2 Acrylic Primer. Top coat with Jones-Blair # Valero Sand Acrylithane C-HS Acrylic Urethane. Two coats required. Color: JB # Valero Sand Top coats: For Reveals / Stars ( IF APPLICABLE ) Jones-Blair Acrylithane C-HS # White Acrylic Urethane. Two coats required. Color: JB # Valero White EFIS : Walls and Fascia Surface Prep: Must be clean, dry and in sound condition. 5

6 Jones-Blair #3091 Gray Multi-Grip 2 Acrylic Latex Primer. Jones-Blair # Valero Sand. Two coats required. Color: JB # Valero Sand PVC Accent Bands on Marquee ( IF APPLICABLE ) Surface Prep: Must be light sanded, clean and dry Jones-Blair #15077 White Multi Purpose alkyd. Top coats: Jones-Blair Acrylithane C-HS # Teal Acrylic Urethane. 2 coats required. Color: JB # Valero Teal Steel Building Form ( IF APPLICABLE ) Jones-Blair #15632 Gray Multi-Purpose Alkyd Primer. Jones-Blair # Valero Gray. Acrylithane C-HS Color: JB # Valero Gray Primers: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic as noted for brick, masonry, stone, EFIS, or Stucco. Where Epoxy Urethane Primer is required ie, factory finished surfaces or other baked enamel finishes and field applied Polyurethane finishes: Jones-Blair #33010/99951 Ureprime White Epoxy Urethane applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Steel Dispenser Island Forms Jones-Blair Multi Purpose #15632 Gray Alkyd (In CA. use #3091 Multi-Grip 2 Gray Acrylic Primer) Color: Jones-Blair Acrylithane C-HS # Valero Gray Urethane. Two Coats Required. JB# Valero Gray 6

7 Primers: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic as noted for brick, masonry, stone, EFIS, or Stucco. Where Epoxy Urethane Primer is required ie, factory finished surfaces or other baked enamel finishes and field applied Polyurethane finishes: Jones-Blair #33010/99951 Ureprime White Epoxy Urethane applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Steel Light Poles / steel Bases / concrete bases Existing painted poles and steel bases Jones-Blair #15632 Gray Multi-Purpose Alkyd Primer. Jones-Blair # Valero Gray Acrylithane C-HS Color: JB # Valero Gray Primers: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic as noted for brick, masonry, stone, EFIS, or Stucco. Where Epoxy Urethane Primer is required ie, factory finished surfaces or other baked enamel finishes and field applied Polyurethane finishes: Jones-Blair #33010/99951 Ureprime White Epoxy Urethane applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall New and existing Bronze steel light poles and fixtures.are NOT TO BE PAINTED 7

8 These will be shipped from the factory with a Bronze color. CONCRETE BASES are NOT TO BE PAINTED Sandblast and remove paint from existing concrete bases Dumpster Enclosure new and existing - METAL Jones-Blair #15632 Gray Multi-Purpose Alkyd Primer. Jones-Blair # Valero Gray Acrylithane C-HS Color: JB # Valero Gray Primers: Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic as noted for brick, masonry, stone, EFIS, or Stucco. Where Epoxy Urethane Primer is required ie, factory finished surfaces or other baked enamel finishes and field applied Polyurethane finishes: Jones-Blair #33010/99951 Ureprime White Epoxy Urethane applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall - WOOD CEDAR.. new and existing Surface Prep: Remove dirt and sand rough surfaces. Finish coat: Jones-Blair Ranchero Acrylic Cover Coat to match color Cedar. APPROVED STAIN FOR CALIFORNIA Jones-Blair Ranchero Acrylic Cover Coat to match color Cedar. - CMU.. new and existing.. SEE Canopy Columns STEEL Jones-Blair #15077 White Multi-Purpose Alkyd Primer. 8

9 Jones-Blair # Valero Tan Acrylithane C-HS Color: JB # Valero Tan CONCRETE Surface Prep: Power wash to remove contaminants. (If slick, etch with a 10% solution of muriatic acid and water then rinse with clean water and allow to dry thoroughly before priming.) Jones-Blair #3090 White Multi-Grip 2 Acrylic. One coat applied at mils dft. Jones-Blair # Valero Tan Acrylithane C-HS Color: JB # Valero Tan Canopy Fascia (Maintenance only otherwise vinyl if indicated) Repairs Patch existing holes in fascia. After cleaning and sanding, fill holes with Bondo metal filler. Sand holes level with deck surface. clean area and lightly sand before priming. Jones-Blair #33010/99951 White Epoxy Urethane Primer if factory finished or coated with two component urethane. Top Coat: Color: Jones-Blair Acrylithane C-HS # Teal Acrylic Urethane. 2 coats required. JB # Valero Teal Jones-Blair #33010-CA/99951 White Epoxy Urethane Primer if factory finished or coated with two component urethane. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall 9

10 2.1.8 Canopy Deck / Building soffits Wood / stucco decks and soffits Surface Prep: Power wash Top Coat: Jones-Blair #3090 White Multi-Grip 2 Acrylic latex. Two coats required. Jones-Blair Acrylithane C-HS # Acrylic Urethane White. Two coats required. Color: JB # Valero White Metal decks and soffits Surface Prep: Power wash, clean with Bleach or as recommended by paint Manufacturer. Remove all rust, sands, runs, oils, grease, chalk or other contaminants by SSPC-SP1, SSPC-SP2, or SSPC-SP3 respectively Repairs: Top coats: Color: Caulking: Patch existing holes in deck. After cleaning and sanding, fill holes with Bondo metal filler. Sand holes level with deck surface. clean area before priming. Jones-Blair #33010/99951 White Epoxy Urethane Primer if factory finished or coated with two component urethane.one coat required. Jones-Blair Acrylithane C-HS # Acrylic Urethane. One coat required applied at mils dft. JB # Valero White At Canopy lights, gutters and leaders. Seal with premium approved waterproof and mildew resistant white caulking, prior to painting.(do not use silicone) Jones-Blair #33010-CA/99951 White Epoxy Urethane Primer if factory finished or coated with two component urethane. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall 10

11 2.1.9 I.D. / Price Sign Poles and Sign Cans ( painted by sign installer) Color: Jones-Blair #15077 White Multi-Purpose Alkyd Primer Jones-Blair # Valero Gray Acrylithane C-HS JB # Valero Gray Jones-Blair #3090 White or 3091 Gray Multi-Grip 2 Acrylic applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Pipe Bollards Jones-Blair #15632 Gray Multi-Purpose Alkyd applied at mils dft. Jones-Blair Acrylithane C-HS Acrylic Urethane below. Two coats required. Colors: For Bollards/Safety Poles At Pump Island Valero Teal At Building Valero Gray At Air & Water Island Valero Gray At Pay Telephones Valero Gray Jones-Blair #3091 Multi-Grip 2 Acrylic Latex applied at mils dft. 11

12 Top Coat: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Hand Rails Jones-Blair #15632 Gray Multi-Purpose Alkyd applied at mils dft. Jones-Blair Acrylithane C-HS Acrylic Urethane # Valero Gray. Two coats required. Jones-Blair #3091 Multi-Grip 2 Acrylic Latex applied at mils dft. Top Coat: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Building flashing / ( standing seam if applicable ) Top Coat: Color: Jones-Blair #33010/99951 White Epoxy Urethane Primer if factory-finished or coated with two component urethane. One coat required. Jones-Blair Acrylithane C-HS # Teal Acrylic Urethane. 2 coats required. JB # Valero Teal Jones-Blair #33010-CA/99951 White Epoxy Urethane Primer if Factory-finished or coated with two component urethane. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall 12

13 Electrical Boxes - Exterior Jones-Blair #15077 White Multi-Purpose Alkyd Primer Jones-Blair # Valero Gray Acrylithane C-HS Color: JB # Valero Gray Jones-Blair #3091 Multi-Grip 2 Acrylic Latex applied at mils dft. Top Coat: Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall H.V.A.C. Housing, Compressor Housings Jones-Blair #15632 Gray Multi-Purpose Alkyd applied at mils dft. Jones-Blair Acrylithane C-HS Acrylic Urethane # Valero Gray. Two coats required. Jones-Blair #3091 Gray Multi-Grip 2 Acrylic applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall 13

14 Equipment Screens (if applicable ) Jones-Blair #3091 Multi-Grip 2 Acrylic Latex applied at mils dft. Jones-Blair Acrylithane C-HS Acrylic Urethane # Valero Gray. Two coats required. Jones-Blair #33010-CA/99951 White Epoxy Urethane Primer if Factory-finished or coated with two component urethane. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Fuel Vent Pipes and Brackets Jones-Blair #15632 Gray Multi-Purpose Alkyd applied at mils dft. Jones-Blair Acrylithane C-HS Acrylic Urethane # Valero Gray. Two coats required. Jones-Blair #3091 Gray Multi-Grip 2 Acrylic applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall 14

15 Street Boxes / Manhole covers Jones-Blair #15077 White Multi-Purpose Alkyd Primer Colors: All colors listed below are Jones-Blair safety enamel colors: Do not paint pre-finished covers as indicated below a b c d Sub Pump Multi-port manhole covers Color: New covers are pre-finished Black, do not paint Paint only existing older covers Tank Level Sensor Manhole cover Color: Jones-Blair #1902 Black Monitor Well Manhole cover Color: New covers are pre finished White, do not paint Paint only existing older covers. Vapor Recovery and Fill covers Unleaded /5931 Jones-Blair White Unleaded Plus Jones-Blair Blue Premium Unleaded Jones-Blair Red Diesel Jones-BlairYellow Vapor Recovery Jones Blair Orange 2.2 BUILDING INTERIOR Refer to plans for colors and location Colors used on the inside of store sales area are as follows: GREEN : Benjamin Moore # HC 124 Caldwell Green ( Satin Finish ) IDYLLIC BLUE Devoe ICI # 1516 ( Satin Finish ) CMU all areas Surface Prep: Remove all loose mortar by rubbing surface with masonry block or scrape with 6 to 8 floor scraper to remove any mortar fins or protrusions. Remove all loose foreign matter with a stiff broom and coat before contamination occurs. Spot Prime: Jones-Blair #3781 Acrylic Latex Block mils dft. 15

16 Top coats: Jones-Blair Rust-Not HP Acrylic. Two coats mils dft. Colors: Satin finish Back Rooms & Office: To match Valero White Sales Area & Checkout: Green & Blue as listed above for interior. Rest Rooms: Tiled walls..see plans Drywall all areas WALLS and CEILING Surface Prep: Paint only clean, dry surfaces. Remove any laitance, dust or contaminants by hand cleaning. Spot Prime: Texture: Jones-Blair #3090 White. One coat required. Walls and Ceiling shall be smooth Top Coat: Jones-Blair Rust-Not HP Satin Latex Finish. Two coats required. WALLS Back Rooms & Office: To match Valero White in 3032 Sales Area & Checkout: Green & Blue as listed above for interior. Rest Rooms: Tiled walls..see plans CEILING: Restroom only: Valero White Acrylic # Doors and Frames.INTERIOR Top Coat: Cased Opening: Jones-Blair #3090 Multi-Grip 2 Acrylic. One coat. Jones-Blair Rust-Not HP Acrylic Gloss. Color: Copper Bangle (SW-1350 if adjacent walls are green. Color: White (3032 Valero White if adjacent walls are white or blue. Jones-Blair Rust-Not HP Gloss Acrylic mils dft. Colors and finish: see top coat above 16

17 2.2.4 STORE FRONT FRAME and ENTRY DOORS NEW: Manufactured by Vistawall Prefinished Custom Color developed by VALSPAR Industrial Coatings For Vistawall to match. Color: Dark Bronze Finish EXISTING: To be painted by Electrostatic Method As recommended by Company performing process Top Coat: Color: Dark Bronze Matt/Satin Finish REPAINTS: If existing color is Dark Bronze: Jones-Blair #33010 Ureprime Epoxy Urethane Primer. One coat required. Jones-Blair Acrylithane 4500-xxxx series to match Dark Bronze. Two coats required. REPAINTS: If existing color is Black: Jones-Blair #33010 Ureprime Epoxy Urethane Primer. One coat required. Jones-Blair #45637-CA Acrylithane HS-3 Satin Finish Urethane. Two coats required Exposed surfaces of Walk-In Cooler (Applies to Volume Shoppers ) Top Coat: Jones-Blair #3090 Multi-Grip 2 White Acrylic Primer. One coat required. SEE SECTION 2.2 for green and Blue interior colors Also refer to plans Restroom Interior (if not FRP or Ceramic Tile) Surface Prep: CMU 17

18 Remove all loose mortar by rubbing surface with masonry block or scrape with 6 to 8 floor scraper to remove any mortar fins or protrusions. Remove all loose foreign matter with a stiff broom and coat before contamination occur. Surface Prep: DRYWALL See section Top Coat: Jones-Blair #3090 Multi-Grip 2 Acrylic White mils dry. Jones-Blair #3032 Rust-Not Hp Acrylic Valero White. Two coats required Painting over existing ceramic wall tile Jones-Blair #3090 Multi-Grip 2 Acrylic 2 mils dry. Finish : Jones-Blair Rust-Not HP Acrylic Gloss applied at 2-3 mils dft in color required by owner. 2.3 CAR WASH - Exterior Building Fascia For Surface Prep, primer and Top coat. SEE SECTION Building Exterior Pipe Bollards Exterior and Interior INSTALL YELLOW PVC SLEEVE WITH TOP PVC CAP Slide sleeve over steel bollard, fill all spaces with foam sealant. Install and secure pvc cap in place with a top set screw Electrical Boxes - Exterior Jones-Blair #15077 White Multi-Purpose Alkyd Primer Jones-Blair # Valero Gray Acrylithane C-HS 18

19 Color: JB # Valero Gray Jones-Blair #3091 Gray Multi-Grip 2 Acrylic applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Mechanical Rooms, Door/Frame/Header - Exterior Color: Jones-Blair #15077 White Multi-Purpose Alkyd Primer Jones-Blair # Valero Gray Acrylithane C-HS JB # Valero Gray Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Storerooms, Door/Frame/Header - Exterior Jones-Blair #15077 White Multi-Purpose Alkyd Primer Jones-Blair # Valero Gray Acrylithane C-HS Color: JB # Valero Gray 19

20 Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Restrooms, Door/Frame/Header - Exterior (if required) Color: Jones-Blair #15077 White Multi-Purpose Alkyd Primer Jones-Blair # Valero Gray Acrylithane C-HS JB # Valero Gray Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Bay, Door/Frame/Header Exterior ( If Applicable ) Color: Jones-Blair #15077 White Multi-Purpose Alkyd Primer Jones-Blair # Valero Gray Acrylithane C-HS JB # Valero Gray or match wall color. Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at mils dft. 20

21 Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall Exhaust Fan Covers - Exterior Jones-Blair #15077 White Multi-Purpose Alkyd Primer Jones-Blair # Valero Gray Acrylithane C-HS Color: JB # Valero Gray or match wall color. Jones-Blair #3090 White Multi-Grip 2 Acrylic applied at mils dft. Jones-Blair Acrylithane HS-3 Acrylic Urethane. Colors shall 2.4 CAR WASH - Interior Restroom CMU (if applicable) Surface Prep: Remove all loose mortar by rubbing surface with masonry block or scrape with 6 to 8 floor scraper to remove any mortar fins or protrusions. Remove all loose foreign matter with a stiff broom and coat before contamination occurs. Color: Valero White. Apply two coats BAY CMU ---- OPTIONAL FINISHES OPTION 1 - PAINTING AN EXISTING CAR WASH BUILDINGS WITHOUT REMOVING THE EXISTING CARWASH EQUIPMENT: 21

22 Valero/Shamrock 2 CAR WASH PAINTING SPECIFICATIONS 1. GENERAL This specification supersedes any previously written or implied specification for painting any existing or new car wash structures for maximum performance at onsite locations. (Includes California) 1.1 Scope This specification covers Valero s requirements for the painting of piping, equipment and typical interior car wash structures. 1.2 Workmanship All work required by this specification shall be performed in accordance with the recommendations of the manufacturer, Jones-Blair Company, Dallas, Texas or its' distributors. The use of coatings other than those specified herein requires Valero Construction Management approval. 2. GENERAL PREPARATION 2.1 Before applying any coating, all contamination, loose paint, rust, mill scale, soaps, oil, grease, dirt, dust and chemicals are to be removed from interior paintable surfaces by chemical wet blasting, hydroblast cleaning or power tools. Abrasive blast cleaning may be necessary on heavily rusted areas, but may be prohibitive in some areas. Allow to dry completely. 2.2 Existing coatings such as epoxy or urethane shall be roughened prior to coating, when necessary, for proper intercoat adhesion by brush-off blast cleaning or power sanding. 3. SURFACE PREPARATION FOR RECOATING 22

23 3.1 Metal Surfaces Only loose, cracked, brittle, or non-adherent coating shall be removed unless otherwise specified. Cleaning shall be performed two Inches beyond the damaged area in all directions or until tightly adhered coating is obtained. Rust spots shall be thoroughly cleaned. Prime immediately after cleaning and surfaces is completely dry. 3.2 The contractor shall have the option to remove all old coating from area where the amount of damaged or loose coating is excessive. 3.3 Do not prime or coat the following surfaces unless they have been previously painted: (a) (b) (c) (d) Non-ferrous metal surfaces such as aluminum, copper, brass, or Monel; Stainless steel; Glass, tile or ceramic; Machined or finished operating parts of machinery, valves or rubber hoses. 3.4 Primer Prime all bare ferrous metal with Jones-Blair #33010 White Epoxy Urethane Primer. (In CA. use #33010-CA) Catalyze 3:1 ratio with #99951 catalyst. Apply primer a minimum of 2 mils DFT. Allow primer to dry a minimum of 8 hours before recoating at F and 50% RH. Primer may be reduced up to 15% with Jones-Blair # Do not thin for brush or roller application. 4.0 PREVIOUSLY PAINTED SURFACES OF BLOCK, CONCRETE, ROUGH- TEXTURED BRICK, ETC Clean as in Section 2 and roughen existing gloss coatings such as urethanes or epoxy. If fillers are removed by cleaning the surface, fill again with Jones-Blair #3781 Acrylic Latex Block Filler. Block filler may be applied by roller but for maximum filling, work filler into crevices with a brush. Allow surfaces to thoroughly dry before top-coating. 5.0 NEW SURFACES AS IN

24 5.1 Clean surfaces free of oil, grease, wax and other foreign matter. Fill all porous surfaces with Jones-Blair #3781 Acrylic Latex Block Filler. For best results brushing should follow spray or roller application while the filler is still wet. A gallon of block filler will typically cover square feet depending on the surface. Allow block filler to dry hours before applying finish coats. 6.0 NEW GLAZED BRICK/PORCELAIN 6.1 Clean free of all foreign matter and prime with Jones-Blair #33010 or #33010-CA Epoxy Urethane Primer as in FINISH COATS 7.1 Urethane Two-Package System 7.2 Jones-Blair Gloss Acrylithane C-HS # White Aliphatic Urethane shall be applied as the topcoats at a minimum of 2 mils DFT. (In CA. use # White. Two coats are required for either coating. These coatings shall be applied to all primed and roughened surfaces. Acrylithane C-HS catalyzes 7:1 ratio with #99979 catalyst. # catalyzes 3:1 ratio with Catalyst. These coatings are very suitable for this application because of the varied types of environments ranging from severely corrosive environments to mild atmospheric conditions. Aliphatic Urethane also has excellent recoatability. 7.3 Mixing and application techniques Jones-Blair Acrylithane C-HS is a two component system and must be mixed. A 7:1 mixing ratio is required. Mix one (7/8) gallon of Acrylithane base material with one (1) pint of #99979 catalyst. (In CA. use # mixed with #99951 Catalyst) Up to one-half (1/2) pint of #21092 thinner may be added, per gallon, of mixed paint for spray application. For brush and roller application thinning is not normally required. Apply Acrylithane only to thoroughly dry surfaces. When applying at temperatures exceeding 80 F, addition of as much as three fluid ounces (1/5 of pint) of #21093 drying retardant per gallon of Acrylithane C-HS or Acrylithane HS-4 (CA.) is recommended. This prevents dry spray and undesired fast drying on the surface being covered as well as on brushes and rollers. For application in temperatures below 45 F, it is recommended that 1/4 ounce of #99011 be added per catalyzed gallon of Acrylithane C-HS or HS-3. Either Acrylithane product or #33010 (#33010-CA in California) Ureprime White Primer may be recoated after one hour at 70 F and 50% RH. ADDITIONAL INFORMATION: For additional technical data on this or other specified products, contact Jones-Blair Paint Co., 2728 Empire Central, Post Office Box 35286, Dallas, TX 75235, or Watts (800) , Customer Service Fax: (800) , Attn: Will Dryden, National Sales/Marketing Mgr. - Oil Services. 24

25 Other information regarding MSDS, etc may be found on the Jones- Blair/Valero website at Note All conduit and plumbing line wall penetrations are to be caulked or sealed with DAP 8641 Clear Silicone Sealant. To be applied after ALL painting is completed OPTION 2 -FIBERGLASS PANELS FOR EXISTING CARWASH BUILDING WITH EXISTING EQUIPMENT TO BE REPLACED ROYAL RENEW PANELING SYSTEM To be installed on walls and ceiling by others. OPTION 3 -FIBERGLASS COATING FOR NEW CARWASH BUILDING. FOR NEW TO INDUSTRY SITES Surface Prep: Walls and ceiling will be thoroughly sanded to a smooth surface. Surface cleaning will be done with air blasting equipment. Top Coat: A two-part Epoxy Urethane Primer designed primarily for concrete adhesion will be used. (Jones-Blair #33010 White) Fiberglass coating Color: White 5W-1 ( Lilly Gelcoat colors ) ALL MATERIAL AND INSTALLATION WILL BE BY SEGUIN FIBERGLASS ( ph ) Bay Conduits / J-Boxes Top Coat: Jones-Blair # Valero White Acrylithane C-HS Urethane Two coats minimum applied at mils dft per coat Roof Downspout and wall Hangers ( If applicable ) Jones-Blair #3090 Multi-Grip 2 Acrylic Latex. 25

26 Top Coat: Jones-Blair Acrylithane C-HS # Valero Gray or match adjacent wall. Two coats minimum. 2.5 PAVEMENT STRIPING AND RAMP STAINS Jones-Blair #4677 Alkyd YELLOW ZONE MARKING PAINT. Surface Preparation: Power wash and clean parking lot surface. Striping: Use 4 wide yellow stripes. Spacing of stripes must comply with plans or as dictated by local coded. ADA STRIPED ACCESS AND SYMBOL Color of stripes and wheelchair symbol must comply with local codes. Jones-Blair ADA Blue latex #8531 for Symbol. PAINT FOR CONCRETE AND SEALED ASPHALT Jones-Blair #4676 Alkyd White Zone Paint for Concrete or Sealed Asphalt on ADA area. Color: B29YZ2 Lead-Free Yellow PAINT FOR UNSEALED ASPHALT Jones-Blair #Acrylic Latex Acrylic Latex Traffic Marking Paint Color: Jones-Blair # Lead Free Yellow ADA RAMP STAIN AND FINISH NOTE: DO NOT STAIN RAMPS UNLESS REQUIRED BY LOCAL CODES Jones-Blair Ranchero Acrylic Penetrating Concrete Stain Color: #3061 Chippendale After grooves are marked in concrete, brush on stain. Do not apply sealer. Allow for proper drying time per Manufacturer. 2.6 WOOD TRELLIS.. Chippendale Apply the following stain Jones-Blair Chippindale #3061 APPROVED STAIN FOR CALIFORNIA Finish coat: Jones-Blair Chippindale #

27 2.7 EXTERIOR ICE MERCHANDISER Vendor usually provides a merchandiser factory painted with Sand If merchandiser has to be painted on site, use the following Jones-Blair #15077 White Multi-Purpose Alkyd Primer Color: Jones-Blair # Valero Gray Acrylithane C-HS JB # Valero Gray END 27

Product Information/Specifications

Product Information/Specifications BARN & FENCE PAINT NO. 25 BARN RED Smooth or rough sawn exterior vertical wood surfaces such as plywood, fences, shingles, shakes, siding. laminates, masonry and stucco surfaces. AVAILABLE IN: Gallon Only

More information

ITEM NO. DESCRIPTION BIDDER CODE NO. UNIT COST UNIT COST 1 GALLON 5 GALLON. 1 Oil Base Exterior House Paint Mobille Paint 5-18 $29.

ITEM NO. DESCRIPTION BIDDER CODE NO. UNIT COST UNIT COST 1 GALLON 5 GALLON. 1 Oil Base Exterior House Paint Mobille Paint 5-18 $29. BID ON: PAINT AND SUPPLIES BID NO: 13-22 OPENED: MARCH 1, 2013 @ 2:00 PM 1 Oil Base Exterior House Paint Mobille Paint 5-18 $29.00 XXX Acrylic Latex Exterior Gloss House Paint 2 Super White Sherwin Williams

More information

Summit Racing Equipment s Paint and Auto Refinishing System was developed specifically for the home enthusiast and small shop owner wanting a

Summit Racing Equipment s Paint and Auto Refinishing System was developed specifically for the home enthusiast and small shop owner wanting a Summit Racing Equipment s Paint and Auto Refinishing System was developed specifically for the home enthusiast and small shop owner wanting a professional-looking paint job for hundreds of dollars less

More information

General Surface Preparation

General Surface Preparation General Surface Preparation Proper surface preparation will contribute significantly to the longevity of Ace Paint products. Follow these general guidelines for best results. CLEAN: Paint will not adhere

More information

SECTION 15420 WATER STORAGE TANK PAINTING

SECTION 15420 WATER STORAGE TANK PAINTING SECTION 15420 WATER STORAGE TANK PAINTING PART 1 GENERAL.01 SCOPE A. Section Includes Surface preparation, shop priming, and field coating for interior wet, interior dry, and exterior surfaces of steel

More information

Triarch Products Over Various Interior Substrates

Triarch Products Over Various Interior Substrates Triarch products work well over a variety of substrates, both for interior and exterior settings. This document will only discuss interior substrates and is not intended to be a technical discussion of

More information

T R A N S F E R A B L E F U L LY

T R A N S F E R A B L E F U L LY HSTOPS A WALL OF WATER 22 FT. HIG! F U L LY T R A N S F E R A B L E RESISTS10 PSI ! 1 F U L LY T R A N S F E R A B L E HSTOPS A WALL OF WATER 22 FT. HIG RESISTS10 PSI Guaranteed To Stop Water Even Under

More information

RAPTOR TRUCK BED LINER - BLACK

RAPTOR TRUCK BED LINER - BLACK 4 x 750ml RAPTOR base coating x L RAPTOR hardener TECHNICAL DATA SHEET & U-POL s RAPTOR Truck Bed Liner is a durable K polyurethane coating that provides surfaces with a protective barrier. RAPTOR Tintable

More information

Successful Painting Jobs Start Here.

Successful Painting Jobs Start Here. Successful Painting Jobs Start Here. The Right Primer Makes All the Difference. Selecting the right primer for the job is a critical part of improving paint coverage and achieving the highest quality finish

More information

SECTION 33 12 19 FIRE HYDRANTS

SECTION 33 12 19 FIRE HYDRANTS SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.

More information

Product Information/Specifications

Product Information/Specifications DECK WASH No. 61 Ideal for the Maintenance Cleaning of Exterior Wood, Vinyl or Composite Decks, Porches, Fences & Siding. AVAILABLE IN: Quart Only No. 61 Clear No. 61 32 oz. NOT TINTABLE 500-600 sq. ft.

More information

Vinyl Composition Tile Installation System

Vinyl Composition Tile Installation System Vinyl Composition Tile Installation System Product Gauge Size Vinyl No-Wax (Dry Back) Urethane No-Wax (Dry Back) 0.045" (1.1 mm) 0.080" (2.0 mm) IMPERIAL TEXTURE 0.094" (2.4 mm) STONETEX ChromaSpin COMPANION

More information

2014 SPECIFICATION GUIDE Conveyor Equipment

2014 SPECIFICATION GUIDE Conveyor Equipment 1 Table of Contents Page Introduction Identifying painting requirements 3 How do I use this Specification Guide 3 Contacting my local Axalta Representative 3 Paint Selection Identifying the correct paint

More information

Installation System. Existing Resilient Sheet Floors

Installation System. Existing Resilient Sheet Floors Vinyl Composition Tile Installation System Product Adhesive/Full Spread Adhesive/Tile-On Comment Imperial Texture MultiColor RAVE Stonetex Companion Square Feature Tile/Strips ARTEFFECTS SAFETY ZONE Vinyl

More information

Newfoundland and Labrador Paint Recycling Program Guidelines

Newfoundland and Labrador Paint Recycling Program Guidelines Newfoundland and Labrador Paint Recycling Program Guidelines 2009Mar25 1 1. INTRODUCTION The Guidelines are intended to provide practical guidance to operators who are participating in the Newfoundland

More information

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS THERMOTEK SELF ADHESIVE MEMBRANE +G OVER DESCRIPTION SELF ADHESIVE OVER (8YR) BS-SA/CS 1 0 No 0. SUBSTRATE 1. BASE SHEET G FIBER GLASS BASE. THERMOTEK SELF ADHESIVE 3.0 FP GRANULE COMPONENTS AND WEIGHTS

More information

SECTION 09900 PAINTS AND COATINGS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

SECTION 09900 PAINTS AND COATINGS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text. A PPG Brand SECTION 09900 PAINTS AND COATINGS Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". PART 1 GENERAL 1.1 SECTION INCLUDES A. Surface preparation and field painting

More information

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1

More information

Estimating Database Checklist

Estimating Database Checklist Estimating Database Checklist If you are creating a new estimating database for projects, the following list offers a thorough listing of Main and Sub Categories. You can also use it as a checklist to

More information

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No. Classification: Cluster: Location: Total Area: No. of Stories Aquarium Acreage Owned: Acquired: 1904 Most Recent Improvements: THE AQUARIUM Close to junction of Inselrhue and Loiter Way, Belle Isle Two

More information

NEOGARD. Preventive Maintenance Manual

NEOGARD. Preventive Maintenance Manual NEOGARD Preventive Maintenance Manual Fluid-Applied Roof Coating Systems December 2014 Notes NEOGARD luid-applied roof coating systems are designed to be long lasting, monolithic membranes which provide

More information

BLADE REPAIR INSTRUCTION BOOKLET

BLADE REPAIR INSTRUCTION BOOKLET BLADE REPAIR INSTRUCTION BOOKLET Contents Section I: Section II: Section III: Section IV: Section V: Section VI: Removing a Blade Refer to this section if you need to remove the blade from an oar shaft.

More information

Solicitation DTFACN-11-R-00079 Attachment #9

Solicitation DTFACN-11-R-00079 Attachment #9 These specs are only a general overview of the typical VOR Roof construction. These are for reference only. Each individual project will have its own specifications. 1 VOR Roof Projects IDIQ Solicitation

More information

Barewood Octagon and Elongated Windows Installation Instructions

Barewood Octagon and Elongated Windows Installation Instructions Step-by-step instructions to a beautiful window. Measuring and Installation of your new window from Century Specialty Windows couldn't be easier with our step-by-step instructions. Quality, function and

More information

INDEPENDENTS AIL RET 2012

INDEPENDENTS AIL RET 2012 RETAIL INDEPENDENTS 2012 Contents Introducing 2 new colours to the Hammerite range: Direct To Rust Metal Paint 4-5 Metalcare - Task Specific Products 6-7 Metalcare - Primers & Converters 8-9 Muted Clay

More information

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components Infrastructure Facility Condition Summary Weighted Avg Condition Score Facility Components Systems Surveyor/ Date Done Comments G Sitework.9 Site Improvements Parking Pedestrian Paving Site Development

More information

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER DESCRIPTION TORCH OVER (15,17,19 YR) TH/BS-TH/CS 2 1 0 No 0. SUBSTRATE 1. THERMOTEK USA 2.0 FV TORCH SMOOTH 2. THERMOTEK USA PRO FP TORCH GRANULE COMPONENTS

More information

SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL SECTION 14 20 10 - FREIGHT & PARKING GARAGE PART I - GENERAL 1.1 SECTION INCLUDES [NOTE to AE: The following lists requirements that are specific to freight elevators. These requirements are in addition

More information

K2 STONE NATURAL VENEER

K2 STONE NATURAL VENEER INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin

More information

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,

More information

Specifications. PermaTone, Inc. Manufacturer s Long Form Specifications Interior Finish Coatings PF-405

Specifications. PermaTone, Inc. Manufacturer s Long Form Specifications Interior Finish Coatings PF-405 PermaTone, Inc. Manufacturer s Long Form PF-405 PART I GENERAL 1.01 SUMMARY This document provides requirements for the proper specification, design, use and installations of PermaTone specialty interior

More information

Pipe Protection Tape System

Pipe Protection Tape System Pipe Protection Tape System PASCO All Weather Pipe Protection Tape is a pure physical barrier that is moisture proof, inert and non-conducting. Whether the need is to protect overhead piping in industrial

More information

ARCHITECTURAL COATINGS PRODUCT INFORMATION. Index by Category

ARCHITECTURAL COATINGS PRODUCT INFORMATION. Index by Category PRIMERS & SEALERS - INTERIOR STOP STAIN Q.D. Oil Base Primer Sealer 19-15 PDS STOP STAIN 2 Acrylic Primer Sealer 219-15 PDS COVENTRY Wood Sealer 19-8 PDS COVENTRY 100% Acrylic Latex Enamel Undercoat 319-8

More information

Acrylic Walls Installation Instructions

Acrylic Walls Installation Instructions Acrylic Walls Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower acrylic walls. If you have any questions on this shower acrylic walls installation

More information

Tractor Painting Tips

Tractor Painting Tips Keeping your tractor or equipment well kept & free from rust & corrosion will extend the life of your investment & help retain its value for a longer period of time. It can be difficult, in many cases,

More information

2015 HOUSE GRANTS PROGRAM REHABILITATION DOS AND DON TS

2015 HOUSE GRANTS PROGRAM REHABILITATION DOS AND DON TS 2015 HOUSE GRANTS PROGRAM REHABILITATION DOS AND DON TS General Principles The s Rehabilitation Dos and Don ts are based on the Standards and Guidelines for the Conservation of Historic Places in Canada,

More information

SECTION 00335 EXISTING HAZARDOUS MATERIALS CONDITIONS

SECTION 00335 EXISTING HAZARDOUS MATERIALS CONDITIONS PART 1 GENERAL 1.01 SUMMARY SECTION 00335 EXISTING HAZARDOUS MATERIALS CONDITIONS A. This section provides a list of known and assumed hazardous materials that may be impacted during renovation, demolition,

More information

Primer-Sealers Solutions

Primer-Sealers Solutions Guide to Primer-Sealers Solutions for interior and exterior use Create a ready-to-paint surface, while sealing in odors and stains, and ensure the durability, appearance and success of your job. Why Prime-Seal

More information

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space) COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.

More information

Rehabilitation of an Aging Concrete Reservoir Adit Tower

Rehabilitation of an Aging Concrete Reservoir Adit Tower Rehabilitation of an Aging Concrete Reservoir Adit Tower Raymond S. Tombaugh, Senior Coatings Consultant KTA-Tator, Inc. and Mongkol Mahavongtrakul, P.E. Corrosion Control Contract Manager San Francisco

More information

16 2 10.3 Materials and Colors

16 2 10.3 Materials and Colors 16 2 10.3 Materials and Colors To create a harmonious and coherent image for each development, building designs shall pay close attention to choice of materials and colors. Building construction shall

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

Colorado State University. Durrell Center Roof Repair

Colorado State University. Durrell Center Roof Repair Colorado State University Durrell Center Roof Repair SPECIFICATION: POLYURETHANE FOAM ROOFING l.0 GENERAL REQUIREMENTS The successful application of a polyurethane foam roofing system is dependent upon

More information

Inspecting to a higher standard.

Inspecting to a higher standard. Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com

More information

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities Division 1 Requirements Design and Construction Quality Campus Master Plans Texas Tech University System Operating and Building Maintenance Project Administration Historically Underutilized Business (HUB)

More information

Architectural Inspection Site Structures

Architectural Inspection Site Structures 0141 Freestanding Shelters Open air shelters not attached to the building. Bike rack shelter with bike racks: This 8'x30' structure is located on the north east side of the building on the wooded landscape

More information

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST SODA SPRINGS HIGH SCHOOL REPAIRS AND UPGRADES SITE Construction Estimate = $100,000

More information

Minor Cracks in Horizontal Surfaces

Minor Cracks in Horizontal Surfaces Cracks, chips and broken or flaking areas in concrete are not only unsightly, they can lead to further deterioration of the surface. The result is a costly replacement project as opposed to a simple repair.

More information

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION 07560 BUR BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION PART 1: GENERAL 1.01 SCOPE: To extend the useful service life of the aged or new asphalt built-up roof system and to reduce cooling

More information

Application of Exterior Wood Finishes

Application of Exterior Wood Finishes Application of Exterior Wood Finishes The following information is excerpted from the publication, Exterior Wood in the South Selection, Applications, and Finishes by Daniel L. Cassens and William C. Feist;

More information

Cascade Remodeling Inc. PO Box 25687 Portland, OR 97298 Catalyzing Euphoria Phone (503) 297-2055, FAX (503) 297-0579 CCB # 67007

Cascade Remodeling Inc. PO Box 25687 Portland, OR 97298 Catalyzing Euphoria Phone (503) 297-2055, FAX (503) 297-0579 CCB # 67007 SPECIFICATIONS For Sample Customer SCOPE OF WORK: The contractor will provide labor and/or materials for the work as outlined in the estimate and the following specification. The contractor s estimate

More information

EXTERIOR PAINT SCHEDULE

EXTERIOR PAINT SCHEDULE A. CONCRETE, STUCCO, AND MASONRY (OTHER THAN CONCRETE MASONRY UNITS): 2. Flat Elastomeric Finish: *1 st Coat: McCormick Interior/Exterior Acrylic Clear Brushing Lacquer Surface Conditioner 01242 OR McCormick

More information

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1. 212 F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1. 212 F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested) Not approved 2063;2064 1,2 2063 ^(ValidationDate) 1 Product description This is a two component solvent free polyamine cured coating. It is a general purpose tank lining with good chemical resistance.

More information

Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent

Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent Scope for Irvinton Village Unit #512 Overall Scope: Demolition, Renovation, and

More information

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or

More information

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings

More information

GUIDELINE SPECIFICATIONS

GUIDELINE SPECIFICATIONS GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced

More information

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.

Smooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36. Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth

More information

March 19, 2014. Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202

March 19, 2014. Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202 Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202 Re: Prospector s Point Walkway/Façade Repairs Martin/Martin, Inc Project No.: 13.0358.S.02 Ms. McDonald: Per your request

More information

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES REFLECTICLEAN ACRYLIC/URETHANE Elastomeric Roofing Systems, Inc 6900 Bleck Dr. Rockford, MN 55373 800.403.7747 -or- 763.565.6900 fax: 763.565.6901 email:

More information

ROOFS - Guidance for Repair, Maintenance and Replacement

ROOFS - Guidance for Repair, Maintenance and Replacement ROOFS - Guidance for Repair, Maintenance and Replacement Guilford Association Architectural Committee ROOFING Slate and tile roofs are a critical design feature of Guilford homes. The homes were designed

More information

Aspect Metal Peel & Stick Tile Installation Guide

Aspect Metal Peel & Stick Tile Installation Guide Aspect Metal Peel & Stick Tile Installation Guide Proper surface preparation is essential for a successful project Failure to follow recommended surface preparation instructions may void the warranty Read

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

FAQs. 19. Does the sub floor need to be level before I install my new direct-to-stud bathtub or shower base?

FAQs. 19. Does the sub floor need to be level before I install my new direct-to-stud bathtub or shower base? 1. Where is the serial number of my tub located? 2. What can I use to clean my tub or shower? 3. What is an Above Floor Rough-in? 4. Can I replace my towel bar? 5. What are grommets? 6. Why do some bathing

More information

09 00 03 GENERAL PROVISIONS

09 00 03 GENERAL PROVISIONS 09 00 03 GENERAL PROVISIONS A. For renovation projects, consider the building s character and existing finishes. All material patches should blend as closely as possible. Some buildings on campus have

More information

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL 1.1 SUMMARY A. This section is a part of the entire set of Contract Documents and shall be coordinated with the applicable

More information

SC2000 CEMENT BONDING PROCEDURES

SC2000 CEMENT BONDING PROCEDURES Pg.1 SC2000 CEMENT BONDING PROCEDURES Widely recognized as the world s finest cold vulcanizing cement REMA SC2000 is the solution to your industrial bonding problems. By using REMA UTR20 hardener with

More information

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick Photo courtesy of Delta Stone, Heber City, UT Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick THIN VENEER INSTALLATION SYSTEMS PREMIUM BONDING MORTARS Premium PCL Stone

More information

[Note: This guide specification may be used for Polomyx All-Acrylic, Polomyx Waterbase and Zolatone Waterbase multicolor finishes.

[Note: This guide specification may be used for Polomyx All-Acrylic, Polomyx Waterbase and Zolatone Waterbase multicolor finishes. GUIDE SPECIFICATIONS SECTION 09945 POLOMYX ALL-ACRYLIC MULTICOLOR WALL FINISH ALL ACRYLIC WATERBASE ******** Polomyx All-Acrylic is a seamless, spray-applied paint system. It is visually complex, layered

More information

Designing Schools To Reduce On-Going And Future Maintenance and Repair Costs

Designing Schools To Reduce On-Going And Future Maintenance and Repair Costs Designing Schools To Reduce On-Going And Future Maintenance and Repair Costs Charles H. Johnson, Consultant School Facilities Planning Division California Department of Education March 7, 2001 1 Designing

More information

Autobody/Collision and Repair Technology/Technician CIP 47.0603 Task Grid

Autobody/Collision and Repair Technology/Technician CIP 47.0603 Task Grid 1 Secondary Task List 100 ORIENTATION 101 Identify opportunities in the auto body field. 102 Identify basic auto body construction. 103 Identify program rules and policies. 104 Identify government agencies

More information

www.citiesinspection.com October 5, 2015 Dear Client,

www.citiesinspection.com October 5, 2015 Dear Client, www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.

More information

How to repair your existing low slope flat roof.

How to repair your existing low slope flat roof. How to repair your existing low slope flat roof. Recycled Rubber Roofing is not a "Roof Coating." It is a liquid emulsion used as the underlayment of a new or retrofit, built-up roofing system. One of

More information

Facility Assessment Report, Montgomery Independent School District

Facility Assessment Report, Montgomery Independent School District THE LEARNING CENTER CAMPUS DATA THE LEARNING CENTER 700 Dr. Martin Luther King Jr. Drive, Montgomery TX 77356 Year Built 1958 Approx. Total Square Footage Grades Served Current Enrollment 22,050 n/a n/a

More information

Floor Pads, Hand Pads, Scrubbing Sponges and Sanding Screens

Floor Pads, Hand Pads, Scrubbing Sponges and Sanding Screens Floor Pads, Hand Pads, Scrubbing Sponges and Sanding Screens Introducing Premium Floor Maintenance Pads from 3M and Triple S 3M and Triple S have teamed up to provide the best of 3M and Scotch-Brite branded

More information

RECOATING AND RENEWING SPF ROOFING SYSTEMS

RECOATING AND RENEWING SPF ROOFING SYSTEMS RECOATING AND RENEWING SPF ROOFING SYSTEMS Procedures, Regional Differences and type of coating systems Bruce Schenke Premium Spray Products REASONS TO RECOAT/RENEW Add a new coating layer to renew the

More information

ALPHA 15-Year Permathane II FR w/granules

ALPHA 15-Year Permathane II FR w/granules ALPHA 15-Year Permathane II FR w/granules Section 07 57 13 Sprayed Polyurethane Foam Roofing Guide Specification PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Furnish all labor, materials, tools and

More information

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11 Page 1 of 11 FEATURES & BENEFITS Q. Is the new Restore 10X Advanced Resurfacer replacing the first generation of Restore 10X? A. Yes, the new Restore 10X Advanced Resurfacer will replace the first generation

More information

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

ELECTRIC PERISTALTIC MORTAR POINTING PUMP ELECTRIC PERISTALTIC MORTAR POINTING PUMP pointing gun & control valve ACF405 PERISTALTIC PuMP hopper feed roller & tube pump for refurbishment & repair trades heritage & conservation bridge & underground

More information

Building Condition Assessment Report

Building Condition Assessment Report Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.

More information

Concrete Resurfacing. System Guide. by Parchem Construction Supplies

Concrete Resurfacing. System Guide. by Parchem Construction Supplies Concrete Resurfacing System Guide by Parchem Construction Supplies Resurfacing Spray-on resurfacing is a 2-3mm topping applied to structurally sound concrete surfaces that are at least 28 days old. Resurfacing

More information

Stucco Repair and Maintenance No. 1.01

Stucco Repair and Maintenance No. 1.01 Tel: 404 346-3666 Toll Free: 800 221-2397 Fax: 404 346-3119 Stucco Repair and Maintenance No. 1.01 These stucco repair and maintenance techniques are intended as a partial guide to repair of stucco walls.

More information

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES Tools Required Tape Measure Hammer Slotted Screw Driver #2 & #3 Philips Screw Driver 3-4 Foot Level 12 Pry Bar Cold Chisel

More information

SURFACE PREPARATION STANDARDS

SURFACE PREPARATION STANDARDS SURFACE PREPARATION STANDARDS TE SWEDIS STANDARDS INSTITUTION: Surface Preparations Standards for Painting Steel Surface (SIS 055900-1967) has gained prominence and acceptance and has served as a model

More information

( II ) INDUSTRIAL & PROTECTIVE SYSTEM

( II ) INDUSTRIAL & PROTECTIVE SYSTEM ( II ) INDUSTRIAL & PROTECTIVE SYSTEM (A) ALKYD BASE QUICK PAINT AUTO GLOSS PAINT GLOSS PAINT VARNISH TOP WOOD VARNISH ALUMINUM TOP RED OXIDE ZINC CHROMATE PRIMER RED OXIDE PRIMER AUTO GLOSS ZINC CHROMATE

More information

UFGS-09 96 00 (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS-09 96 00 (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-09 96 00 (November 2014) ----------------------------- Preparing Activity: NASA Superseding UFGS-09 96 00 (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES ARCHITECTURAL SPECIFICATIONS / CAD MODELS With more than 40 years of manufacturing high quality, innovative building products in the commercial and residential markets, Custom Building Products TVISTM

More information

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES Liquid Coating Properties Composition VOC Content, ASTM D2369 Water Content, ASTM D4017 Physical Properties Calculating Physical Constants of Coatings, ASTM D5201 Density, ASTM D1475 Flash Point, ASTM

More information

Note: Minor color change may occur in exposed service, but corrosion protection will not be compromised

Note: Minor color change may occur in exposed service, but corrosion protection will not be compromised DESCRIPTION One component, high-build heat-resistant inert multipolymeric matrix coating to prevent corrosion under insulation (CUI) of carbon and stainless steel to temperatures ranging up to 650 C (1200

More information

Bath Fixtures. Mirrors. Showers. Care and Maintenance. General Care Guidelines. Bathtubs

Bath Fixtures. Mirrors. Showers. Care and Maintenance. General Care Guidelines. Bathtubs ONE Bathrooms 5 Bath Fixtures The bathroom fixtures have protective surfaces that preserve their appearance and performance. The bathtubs, sinks, showers, and toilets in your new home have protective surfaces.

More information

1bathrooms. bathrooms. 2010 PulteGroup, Inc. All Rights Reserved.

1bathrooms. bathrooms. 2010 PulteGroup, Inc. All Rights Reserved. 1 5 2010 PulteGroup, Inc. All Rights Reserved. bath fixtures The bathroom fixtures have protective surfaces that preserve their appearance and performance. The bathtubs, sinks, showers, and toilets in

More information

Table of Contents. Benefits of UNIFLEX Fluid Applied Roofing Systems 2 3. Elastomeric Finish Coats 4 5. Aluminum Finish Coats 6

Table of Contents. Benefits of UNIFLEX Fluid Applied Roofing Systems 2 3. Elastomeric Finish Coats 4 5. Aluminum Finish Coats 6 PORTFOLIO Table of Contents Benefits of UNIFLEX Fluid Applied Roofing Systems 2 3 Elastomeric Finish Coats 4 5 Aluminum Finish Coats 6 Asphalt Emulsion Coatings 7 Base Coats & Primers 8 9 Patch & Repair:

More information

Shower Walls and Tub Surrounds

Shower Walls and Tub Surrounds Reverso en español TEC Skill Set How-To Project Guide Shower Walls and Tub Surrounds 3 Steps to a Beautiful Tile Surface! 1. Prepare the surface 2. Set the tile 3. Grout and caulk H.B. Fuller Construction

More information

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman. Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal

More information

SEAMS SEAMING USING SEAM TAPE

SEAMS SEAMING USING SEAM TAPE SEAMING USING SEAM TAPE SEAMS The membrane should be positioned so that the width of the seam is 3. Remove excess chalk from a chalk line by snapping the line into the air and then chalk a line one-quarter

More information

Asbestos Management Program

Asbestos Management Program Asbestos Management Program Facilities and Operations Revision #4: February 17, 2012 Page IMPORTANT Asbestos related incidents must be reported IMMEDIATELY to your supervisor Emergency Contacts During

More information

OPTIMUS WORK CLASSIFICATION LIST ENTER ALL THAT APPLY

OPTIMUS WORK CLASSIFICATION LIST ENTER ALL THAT APPLY Cost Code # Description Cost Code # Description 01 00 00.001 General Requirements 02 00 00.001 Existing Conditions 01 31 19.13.001 Preconstruction Meetings 02 21 00.001 Surveys 01 32 33.001 Photographic

More information

Tundra Series Windows January 2016

Tundra Series Windows January 2016 Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing

More information

SECTION 03 35 43 POLISHED CONCRETE FINISHING

SECTION 03 35 43 POLISHED CONCRETE FINISHING SECTION 03 35 43 POLISHED CONCRETE FINISHING PART 1 - GENERAL 1.01 SUMMARY A. Provide polished concrete finishing system where indicated on drawings, complete. This section includes the following: 1. Concrete

More information

Epoxy Floor Coating Problem Solving Guide

Epoxy Floor Coating Problem Solving Guide Table of Contents: Page: Troubleshooting Issue: 2. Color Differential 3. Fish Eye 4. Milky or Cloudy Coatings 5. Orange Peel 6. Peeling or Delamination 8. Delamination between Coats 9. Pinholes/Bubbling

More information