AS-Interface. 6/2 System overview 6/2 Transmission technology 6/3 Configuration examples 6/4 Communication overview
|
|
|
- Regina Stafford
- 9 years ago
- Views:
Transcription
1 /2 System overview /2 Transmission technology /3 Configuration examples /4 Communication overview /5 ASIsafe /5 F adapters for EMERGECY-STOP control devices / SIMATIC FS00 laser scanner / ASIsafe laser scanner /10 Slaves /10 Contactor and Contactor Assemblies /10 SIRIUS function modules for /11 Motor starters for operation in the control cabinet Sec.10 SIRIUS 3RA compact feeders General data /11 SIRIUS 3RA compact feeders Add-on modules for Sec.10 SIRIUS 3RA compact feeders Accessories /12 Motor starters for operation in the field, high degree of protection /12 SIRIUS M200D motor starters General data /13 M200D Motor Starters for /18 M200D Basic / M200D Standard motor starters /19 SIRIUS M200D motor starters Accessories /24 SIRIUS MCU motor starters General data /29 MCU motor starters, locally controlled plastic enclosures, electromechanical switching /30 MCU motor starters, I/O-controlled plastic enclosures, electromechanical switching /31 MCU motor starters for plastic enclosures, electromechanical switching /32 MCU motor starters for metal enclosures, electromechanical switching /34 MCU motor starters for metal enclosures, electronic switching /35 SIRIUS MCU motor starters Accessories /3 SIAMICS distributed inverters /3 SIAMICS G110D distributed inverters /38 3SF5 pushbutton units and indicator lights /38 enclosures with standard fittings Siemens IK PI ews January 2010
2 Introduction System overview Transmission technology Siemens AG 2010 Overview is an open, international standard according to E and IEC for process and field communication. Leading manufacturers of actuators and sensors all over the world support the. Interested companies are provided with the electrical and mechanical specifications by the Association. is a single master system. For automation systems from Siemens, there are communications processors (CPs) and routers (links) which control the process or field communication as masters, and actuators and sensors which are activated as slaves. Laptop Remote access, e.g. via teleservice PC Control and monitoring system Telecontrol and substation control Motion Control Systems Database Server PC/PG/IPC Security Point otebook Access Point PC/PG/IPC umeric Control Field device for intrinsically safe area Coupler Link PROFIBUS PA Motion Control Systems Access Point Power supply LOGO! Controller Power supply SIAMICS Drives Sensors KX Sensors Slaves Compact starter Compact feeder Slaves Signalling column G_IK10_XX_20002 Benefits A key feature of technology is the use of a shared two-conductor cable for data transmission and the distribution of auxiliary power to the sensors/actuators. An power supply unit that meets the requirements of the transmission method is used for the distribution of auxiliary power. The cable used for the wiring is mechanically coded and hence protected against polarity reversal and can be easily contacted by the insulation piercing method. Elaborately wired control cables in the control cabinet and marshalling racks can be replaced by. With this concept, you become extremely flexible and achieve high savings. Application Operating modes Generally, master interfaces have the following operating modes: I/O data exchange In this operating mode, the inputs and outputs of the binary slaves are read and written. Analog value transmission masters according to the Specification V2.1 or V3.0 support integrated analog value processing. This means that data exchange with analog slaves (according to Analog Profile 7.3 or 7.4) is just as easy as with digital slaves. Command interface In addition to I/O data exchange with binary and analog slaves, the masters provide a number of other functions through the command interface. Hence it is possible, for example, for slave addresses to be issued, parameter values transferred or diagnostics information read out from user programs. /2 Siemens IK PI ews January 2010
3 Introduction System overview Configuration examples Overview Process or field communication The is used when individual actuators/sensors are spatially distributed through the machine (e.g. in a bottle filling plant, production line, among other things). The replaces complex cable harnesses and connects binary and analog actuators and sensors, such as proximity switches, valves or indicator lights, to a control, for example, SIMATIC or a PC. In practice this means: Installation is straightforward, because data and energy are conveyed together over one cable. o special know-how for installation and commissioning is required. And thanks to the simple laying of the cable, its clearcut structure and special version, there is not only far less risk of errors, but also less effort during maintenance and servicing. Example of a system configuration Siemens IK PI ews January 2010 /3
4 Introduction System overview Communication overview Overview System components umerous system components are offered for implementing the communication. The key elements of a system installation are: Master interface modules for central control units such as SIMATIC S5 and SIMATIC S7, ET 200M distributed peripherals or routers from PROFIBUS/PROFIET to shaped cables etwork components such as repeaters and extension plugs Power supplies for the slaves Modules for connection of standard sensors/actuators Actuators and sensors with integrated AS-i slave Safety modules for transmitting safety-oriented data through Addressing units for setting the slave addresses during commissioning masters and links (network transitions) Siemens AG 2010 Features Standard E / IEC 1158 Topology Line, star or tree structure (same as electrical wiring) Transmission medium Unshielded two-conductor cable (2 x 1.5 mm 2 ) for data and auxiliary power Connection methods Contacting of the cable by insulation piercing method Maximum cable length 100 m without a repeater 200 m with extension plug 300 m with two repeaters connected in series 00 m with extension plugs and two repeaters connected in parallel Larger cable lengths are possible when additional repeaters are connected in parallel Maximum cycle time 5 ms with full expansion using standard addresses, 10 ms with full expansion using A/B addresses, profile-specific for Spec. 3.0 slaves umber of stations per line umber of binary sensors and actuators Access control Error safeguard 31 slaves according to Spec. V2.0; 2 slaves (A/B technology) according to Spec. V2.1 and V3.0, integrated analog value transmission Max. 124 DI/124 DO according to Spec. V2.0; max. 248 DI/18 DO according to Spec. V2.1; max. 49 DI/49 DO according to Spec. V3.0 Cyclic polling master slave method, cyclic data transfer by host (PLC, PC) Identification and repetition of faulty message frames More information For the modules referred to above, please also note the conditions of application and the additional information. system manual More information about is available in the System Manual. The German-language System Manual can be downloaded for free from the Internet at: support.automation.siemens.com/ww/view/de/ The English-language System Manual can be downloaded for free from the Internet at: support.automation.siemens.com/ww/view/en/ Internet You can find more information on the Internet at: support.automation.siemens.com/ww/view/en/ / /4 Siemens IK PI ews January 2010
5 ASIsafe F adapters for EMERGECY-STOP control devices Overview The F adapter is used to connect an EMERGECY- STOP control device according to ISO from the 3SB3 series to the bus system. The F adapter is suitable for control devices with mounting on front plates. The F adapter has a safe 2E slave and is snapped from behind onto the EMERGECY-STOP device (actuator). In the 2E/1A expanded version, an output is also available for actuating an indicator light with LED. Connection to the bus cable is made with screw terminal, spring-type terminals or an insulation piercing method depending on the version. Addressing is performed using the connection or the integrated addressing socket. Safety category 4 (SIL3) is achieved with the adapter. Selection and ordering data Version Connection Order o. 3SF AA03 F adapters for 3SB3 EMERGECY-STOP actuator For mounting on front plate 2I Screw terminals 3SF AA03 2I/1O, with output for LED control 3SF AB03 2I Spring-type terminals 3SF AA04 2I/1O, with output for LED control 3SF AB04 2I Insulation piercing 3SF AA05 method 2I/1O, with output for LED control 3SF AB05 3SF AA04 3SF AA05 Siemens IK PI ews January 2010 /5
6 ASIsafe SIMATIC FS00 laser scanner ASIsafe laser scanner Siemens AG 2010 Overview The provide perfect all-round protection up to Category 3 according to E 954-1, SIL 2 according to IEC 1508, and PL d according to ISO SIMATIC FS00 laser scanners work in an operating field of 190 and over a distance of up to.25 m. In this range the laser scanner reliably senses every object and every person. And it works so simply: The distance sensor emits light pulses at regular intervals. If they hit an obstruction, the sensor receives the reflected light and evaluates it. If this is evaluated as the predefined area to be protected, a Stop function is triggered. With up to 8 programmable protective fields that can be selected during operation, our laser scanners can be optimally adapted to any application on machines, production robots, conveyor systems, or vehicles. Different variants support optimal integration in the automation system: Whether conventionally in the safety circuit, over PROFIBUS with PROFIsafe or over with ASIsafe. The laser scanner is an optical distance sensor for flexible monitoring of hazardous areas in horizontal applications, for access control in vertical applications, and for motion monitoring. Integration X5 and and or X1 X2 X3 X4 FS10_0013 Terminal Description Item Connectable accessories Order o. X1 M12 connector for connection (bus connection and 24 V DC power supply) 1 Laser scanner connecting cable to M12 adapter 3RG EA (1 m) 3RG EB (2 m) 2 M12 adapter 3RG DG X2 Connection for addressing and diagnostics unit 3 addressing and diagnostics unit 3RK AB01 X3 X4 M12 socket for connecting the changeover for the protective fields M12 connector for connecting a restart button (optional) 4 Connecting cable with M12 socket and M12 plug (3-core) 5 M12 jumper plug (suitable for protection field 1) 3RX GF32-1AB5 (1.5 m) 3RG DF M12 connector with terminal housing, 5-pin 3RX CD55 7 M12 cable socket with terminal housing, 5-pin 3RX CB55 X5 Optical PC interface 8 PC connecting cable for laser scanner with optical interface, 9-pin 3RG DC / Siemens IK PI ews January 2010
7 ASIsafe SIMATIC FS00 laser scanner ASIsafe laser scanner Technical specifications Type ASIsafe laser scanner Type ASIsafe laser scanner Protective field Protective field 2.15 m, 4 m,.25 m Degree of remission min. 1.8 % Resolutions Response time 2-fold evaluation (2 scans) Adjustable up to 1 scans Resolutions: 30, 40, 50, 70, 150 mm 85 ms (laser scanner only, without system times) 45 ms (laser scanner only, without system times) umber 4 / 8 (selectable via switched inputs) Safety category acc. to IEC 150 SIL 2 Output Safe interface Start-up Start-up test and start-up disable can be set separately Warm restart 10 ms to 10 s (settable or manually) Protective field additional distance with dust suppression 83 mm deactivated with dust suppression activated - For protective fields < 3.5 mm 83 mm - For protective fields > 3.5 mm 100 mm Additional distance for retroreflectors or strongly reflective surfaces (such as certain metals or ceramics in the scan plane) - Over 1.2 m behind the 0 mm protective field line - In the protective field or 110 mm up to 1.2 m behind the protective field line Warning zone Detection zone m Degree of remission min. 20% Object size mm Response time 2-fold evaluation (2 scans) 85 ms (laser scanner only, without system times) Adjustable up to 1 scans 45 ms (laser scanner only, without system times) umber of warning zones 4 / 8 (selectable via switched inputs) Output Contour measurement Detection zone m Degree of remission min. 20% Output RS232 serial interface via infrared interface Radial resolution 5 mm Lateral resolution 0.3 Supply voltage via network V (according to specification) via external supply 24 V DC (+/-20 %) ote The power supply unit of the external power supply as well as the power supply unit used to supply the components must provide safe isolation from the supply according to IEC 0742 and bridge short-term power failures of up to 20 ms (e.g. the power supply unit 3RX AA00) Overcurrent protection Fuse 1.25 A, slow acting Current consumption from the 400 ma supply circuit, typically Current consumption from the 50 ma circuit, typically Inputs Restart/Reset Connection of a command device for operating mode "With restart inhibit" and/or device reset, dynamically monitored, 24 V DC opto-decoupled Field pair switchover Selection of 4 field pairs over 4 control lines with internal monitoring (1 field pair = 1 protective zone and 1 warning zone), 24 V DC opto-decoupled Signal definition High (logic 1) V Low (logic 0) < 3 V Control cable Length address programming RS232 interfaces by means of infrared interface Optical system max. 50 m (0.5 mm 2 conductor cross-section, shielded) Connection of a generally available address programming device For device parameterization and field function Range of angle 190 Angle resolution 0.3 Lateral tolerance Without mounting system (with ± 0.18 reference to rear of enclosure) With mounting system (with reference to the mounting surface) ± 0.22 Scan rate 25 scans/s or 40 ms/scan Laser protection class According to standard E , Class 1 (safe for eyes) Wave length 905 nm Beam divergence Time basis 2 mrad 100 s Siemens IK PI ews January 2010 /7
8 ASIsafe SIMATIC FS00 laser scanner ASIsafe laser scanner Siemens AG 2010 Technical specifications (continued) Type Environment and material Degree of protection Ambient temperature ASIsafe laser scanner IP5 Operation C Storage C Housing insulation class Type of protection 2 Humidity according to DI 40040, Table 10, identification letter E (fairly dry) Dimensions (W H D) in mm Weight 2.25 kg Emitter Infrared laser diode (λ = 905 nm) Housing Cast aluminum, plastic, steel connection plate Type Vibratory load over three axes according to IEC 008, Part 2- Continuous shock over three axes according to IEC 008, Part 2-29 Rotating mirror drive Rotating mirror bearings ID code I/O code Slave address Cycle time according to specification Profile ASIsafe laser scanner Hz, max. 5 g 10 g, 1 ms Brushless DC motor Maintenance-free ball bearings B 0 (four data bits as outputs) Programmed by user in the range from 1 to 31 (delivery status = 0) 5 ms Safe slave "Safety of machinery" for ASIsafe laser scanners IEC/E 149 IEC/E 1508 PL Category Cat PFHD TM p.a. ISO Laser scanner Type 3 SIL 2 d Ordering data Order o. Order o. ASIsafe laser scanner for Accessories protection in a horizontal plane, including LS4soft software Assembly system 3RG AA SIMATIC FS20I 3SF78 34-DD00 Swivel-mounted, for easy alignment Maximum size of protective field: 4m Adapter plate 3RG AB 4 protective field/warning field for PLS mounting support pairs Resolutions: 70, 150 mm Cleaning set 3RG RS ASIsafe laser scanner for protection in a horizontal and vertical plane, including LS4soft software SIMATIC FS0I Maximum size of protective field: 4m 8 protective field/warning field pairs Resolutions: 30, 40, 50, 70, 150 mm SIMATIC FS0 LR Maximum size of protective field:.25 m 8 protective field/warning field pairs Resolutions: 30, 40, 50, 70, 150 mm ASIsafe laser scanner for protection in a horizontal and vertical plane and motion monitoring, including LS4soft software SIMATIC FS70 Maximum size of protective field: 4m 8 protective field/warning field pairs Resolutions: 30, 40, 50, 70, 150 mm SIMATIC FS70 LR Maximum size of protective field:.25 m 8 protective field/warning field pairs Resolutions: 30, 40, 50, 70, 150 mm 3SF78 34-DE00 3SF78 34-LE00 3SF78 34-DM00 3SF78 34-LM00 Includes cleaning fluid (1000 ml), cloths (100 units) Connectors and cables PC connection cable for and PROFIBUS laser scanner Includes plug (9-pin) and optical interface M12 jumper plug (suitable for protection field 1) M12 adapter For and power supply M12 laser scanner M12 adapter connection cable 5-pin, 1 m 5-pin, 2 m 3RG DC 3RG DF 3RG DG 3RG EA 3RG EB /8 Siemens IK PI ews January 2010
9 ASIsafe SIMATIC FS00 laser scanner ASIsafe laser scanner Dimensions R Top view a s b approx. 220 a b R approx approx a = rotating mirror axis b = scan plane ASIsafe laser scanner 23 5, 51,5 74, , SC Assembly system 3RG AA Schematics X5 X1 X2 X3 X4 X1 connection (Bus connction and 24 Volt power supply) X2 connection for address programming device X3 Connection protective fields switchover X4 Connection restart button X5 Optical PC Interface Siemens IK PI ews January 2010 /9
10 Slaves Contactor and Contactor Assemblies SIRIUS function modules for Siemens AG 2010 Overview Benefits The SIRIUS function modules for connecting to the control system offer many different advantages. The most important are: Reduction of control current wiring through plug-in technology, feeder groups and integrated monitoring of circuit breaker and contactor Reduced space requirement in the control cabinet through fewer digital inputs and outputs in the control system Easy configuring through operation of feeders instead of individual contactors Enhanced operational reliability and quick wiring thanks to spring-type connections Can be flexibly combined with many automation solutions using the open, standardized IO-Link wiring system Small number of variants by using identical modules for size S00 and S0 contactors This means that the SIRIUS feeder is fully integrated in the automation landscape and can use all the advantages of TIA (e.g. integration in the TIA Maintenance Station). 3RA27 12 function module for A motor feeder which is configured with 3RT2 contactors can be connected with the help of 3RA27 function modules to a higherlevel control system. The SIRIUS function modules for connection to the control system are available in an AS-i version and in an IO-Link version. The function modules for connecting to the control system are available for direct-on-line, reversing and wye-delta starters. They are plugged directly into the front interface of the 3RT2 contactors and therefore require one contactor with communication interface per feeder (see Catalog news "LV 1 SIRIUS Innovations 11/2009, Chapter 3). The function modules perform the following tasks: Communication, e.g. contactor operation and feedback, ready signal Electrical interlocking, e.g. for the reversing and wye-delta starter Timing relay function, e.g. wye-delta reversing time Communication information and control supply voltage are passed on through module connectors so that the complete control current wiring on the starter is no longer needed. The function modules are equipped with removable terminals with screw or spring-type connections. They also have an input for local disconnection, which can be connected, for example, to a limit switch. The 3RA27 function modules for connection are implemented in A/B technology, making it easy to connect up to 2 feeders (regardless of whether they are direct-on-line, reversing or wye-delta starters) to an AS-i master. This results in a significant reduction of wiring compared to the conventional parallel wiring method. The electrical connection is made using standard cables. The process image corresponds to that of the compact feeder (see Chapter of the Catalog news "LV 1 SIRIUS Innovations 11/2009), and to that of all motor starters. Easy, duplicatable programming of the control system is thus possible. Application The SIRIUS function modules for connecting to the control system can be used wherever standard induction motors up to 38 A (approx kw/400 V) with 3RT2 contactors are started. The connection is recommended wherever load feeders are used in distributed applications. Approvals according to IEC, UL and CSA standards have been issued for the function modules. Selection and ordering data For selection and ordering data, see the Catalog news "LV 1 SIRIUS Innovations 11/2009", Chapter 3 (Accessories for 3RT2 contactors) and Chapter (Accessories for 3RA2 Load Feeders). Accessories For the function modules, there is a selection of different module connectors that can be used if contactor assemblies for wyedelta starting are to be configured for multiple sizes or non-sideby-side arrangements. More information More information can be found in the Catalog news "LV 1 SIRIUS Innovations 11/2009" or in the Industry Mall. For example: Details of power contactors for switching motors and contactor assemblies can be found in in the aforementioned Catalog news, Chapter 3 or in the Industry Mall under "Automation" --> "Industrial Communication" --> "" --> "Slaves" --> "Contactors and Contactor Assemblies" Details of function modules for can be found in the aforementioned Catalog news, Chapter 3 or in the Industry Mall under "Automation" --> "Industrial Communication" --> "" --> "Slaves" --> "Contactor and Contactor Assemblies" --> "SIRIUS Function Modules for " Details of motor starters for operation in the control cabinet can be found in the aforementioned Catalog news, Chapter or in the Industry Mall under "Automation" --> "Industrial Communication" --> "" --> "Slaves" --> "Motor Starters for Operation in the Control Cabinet" /10 Siemens IK PI ews January 2010
11 Slaves Motor starters for operation in the control cabinet SIRIUS 3RA compact feeders Add-on modules for Overview The following add-on modules are available for communication of the 3RA compact feeder with the control system using : AS-i add-on module AS-i add-on module with two local inputs AS-i add-on module with two free external inputs AS-i add-on module with one free external input and one free external output AS-i add-on module with two free external outputs The AS-i add-on modules can be combined only in connection with compact feeders with a rated control supply voltage of 24 V AC/DC. Addressing unit for addressing the AS-i add-on module Selection and ordering data AS-i add-on modules 3RA9 70-3A Type AS-i add-on module For communication of the compact feeder with the control system using AS-i add-on module with two local inputs For safe disconnection through local safety relays, e.g. cable-operated switches AS-i add-on module with two free external inputs Replaces the digital standard inputs "Motor On" and "Group warning" AS-i add-on module with one free external input and one free external output Replaces the digital standard input "Group warning" AS-i add-on module with two free external outputs Only for direct-on-line starters Replaces the digital standard output "Motor left" AS-i add-on module for on-site controller Either control of the compact feeder using or using on-site switches Order o. 3RA9 70-3A 3RA9 70-3B 3RA9 70-3C 3RA9 70-3D 3RA9 70-3E 3RA9 70-3F 3RA9 70-3F 3RK AB01 Addressing units for AS-i add-on modules For active modules, intelligent sensors and actuators According to Version 2.1 Including expanded addressing mode Scope of supply - 1 addressing unit - 1 operating manual (German, English, French, Spanish, Italian) - 1 addressing cable (1.5 m, with jack plug) 3RK AB01 Siemens IK PI ews January 2010 /11
12 SIRIUS M200D motor starters General data Overview Benefits M200D motor starters provide the following advantages for customers: High plant availability through plug-in capability of the main circuit, communication and IOs relevant for installing and replacing devices Cabinet-free construction and near-motor installation thanks to the high degree of protection IP5 The motor starters record the actual current flow for the parameterizable electronic motor overload protection. Reliable messages concerning the overranging or underranging of setpoint values for comprehensive motor protection. All motor protection functions can be defined by simple parameterization Low stock levels and low order costs through a wide setting range for the current or a wide setting range for the electronic motor protection of 1:10 (only 2 device versions up to 5.5 kw) The integrated wide range for the current enables a single device to cover numerous standard motors of different sizes Comprehensive offering of accessories, including readyassembled cables The intelligent and highly SIRIUS M200D motor starters for the decentral installation, start, monitor and protect motors and The M200D motor starters can be installed with a few manual loads up to 5.5 kw. steps. The integrated plug-in technology enables far lower M200D motor starters are available in four versions: wiring outlay: preassembled cables can be plugged directly onto the motor starter module M200D M200D M200D M200D Easy and user-friendly installation because all versions have AS-i Basic AS-i Standard PROFIBUS PROFIET the same enclosure dimensions Motor control with Fast and user-friendly commissioning using an optional AS-i Communication PROFIBUS PROFIET manual on-site controller Mechanical or electronic switching Increase of process speed through integrated functions such as "Quick-Stop" and "Disable Quick-Stop", e.g. at points and crossings Electronic switching with soft starter functionality Optional manual on-site controller with momentary-contact -- and latching operation for easier start-up and easier service Basic functionality All M200D motor starter versions have the following functions: Application Available as direct-on-line and reversing starters in a rugged The high degree of protection IP5 makes the M200D motor design starters suitable, in particular for use on extensive conveying Electromechanical or solid-state switching version systems such as those found in mail sorting centers, airports, automotive factories and the packing industry. Little variance only 2 device versions up to 5.5 kw thanks to wide range setting For simple operating mechanism tasks, particularly in conveyor applications, the new SIAMICS G110D frequency converter All versions have the same enclosure dimensions series with a performance range from 0.75 kw to 7.5 kw and degree of protection IP5 is the ideal partner for the M200D motor Degree of protection IP5 Quick and failsafe wiring of system and motor cables using starters. The SIAMICS G110D frequency converters permit ISO plug-in connector technology (Q4/2 and Q8/0) continuous speed control of three-phase asynchronous motors and meet the requirements of conveyor applications with frequency control (for more information, see Catalog D 11.1). Robust and widely used M12 connection method for digital inputs and outputs Integrated feeder connector monitoring Full motor protection through overload protection and a temperature sensor (PTC, TC) Short-circuit and overload protection integrated Integrated repair switch lockable with 3 locks (multi-level service) Uniform wiring to the G110D/G120D frequency converters and to the ET 200pro distributed peripherals system Extensive diagnostics concept using LEDs Optional integrated manual on-site controller with key-operated switch (ordering option) Optionally available brake actuation with voltages from 180 V DC (no rectifier needed in motor) or 230/400 V AC (order versions) /12 Siemens IK PI ews January 2010
13 M200D Motor Starters for Overview The M200D motor starter versions SIRIUS M200D, AS-i Basic and SIRIUS M200D AS-i standard (for basic functionality see M200D motor starters, General data.) exist for motor control via. SIRIUS M200D AS-i Basic Functionality Easy and fast on-site start-up through parameterization of local setting elements (DIP switches) and rotary coding switches for adjusting the rated operational current. The rotary coding switch has an OFF position for deactivating the overload protection with the help of the thermal motor model when using a temperature sensor. Communication AS-i communication with A/B addressing according to Spec V2.1 The AS-i bus is connected cost-effectively using an M12 connection on the device. Of the 4 digital inputs, 2 are contained in the process image and can therefore be used in the PLC program. The other 2 inputs are locally effective and permanently assigned with functions. The LEDs can provide comprehensive diagnostics of the device on the spot. In addition to diagnostics using the PAE process image, the device can create up to 15 different diagnostic signals per slave. The message with the highest priority can be read out through the AS-i communication. This is yet another new development which distinguishes the M200D AS-i Basic motor starter from the rest of the market and adds innovative technology, maximum availability and transparency to the system. SIRIUS M200D AS-i Standard The intelligent, highly flexible M200D AS-i Standard motor starters in A/B technology are designed to start and protect motors and loads up to 5.5 kw. They are available in direct-on-line or reversing starter variants, in a mechanical version and also an electronic version (the latter with soft start function). The M200D AS-i Standard motor starter is the most functional member of the SIRIUS motor starter family in the high degree of protection IP5 for AS-i Communication. It is designed to be compatible with other SIRIUS M200D motor starter products and the frequency converter and the ET 200pro peripheral system. Functionality AS-i communication with A/B addressing according to Spec 3.0 Electronic version also with soft start function AS-i slave profile 7.A.E / 7.A.5 with process image E/4A Full TIA integration: All digital inputs and outputs exist in the cyclic process image and are visible through AS-i, providing maximum flexibility and best adaptability to the application Additionally expanded diagnostics using data record through AS-i bus Complete plant monitoring using statistics data record and current value monitoring by means of data records Parameterization through AS-i bus with the help of data records or an expanded process image from the user program Control of the motor starter using a command data record from the user program Flexible assignment of the digital inputs and outputs with all available assignable input actions Parameterization using Motor Starter ES at the local interface (ordering option for start-up software) Diagnostics with the help of Motor Starter ES (ordering option for start-up software) Mounting and installation The M200D motor starters can be installed with a few manual steps. The integrated plug-in technology enables far lower wiring outlay. Connecting cables can be plugged directly onto the motor starter module. Swapping of the connecting wires and malfunctions within the plant are prevented by preassembled cables. The AS-i bus is connected cost-effectively using an M12 connection on the device. All versions have identical enclosure dimensions for easier system design and conversion. Parameterization and configuration The particularly robust M200D AS-i Standard motor starter is characterized by numerous functions which can be flexibly parameterized. It enables highly flexible parameterization through the AS-i bus using data records from the user program as well as user-friendly local parameterization using the Motor Starter ES start-up software through the local point-to-point interface. Functions can be flexibly assigned to the digital inputs and outputs, adapting them to all possible conveyor applications. All motor protection functions, limit values and reactions can be defined by parameterization. The AS-i Standard is unique. In its E/4A process image, the motor starter sends all 4 digital inputs and the digital output via the process image to the PLC in cyclic mode. System configuration and system documentation are facilitated not least by a number of CAX data. Operation The new motor starter generation is characterized by high functionality, maximum flexibility and the highest level of automation. All digital inputs and outputs exist in the cyclic process image. All limit values for monitoring functions and their reactions are parameterizable and therefore adaptable to the application. The motor starters record the actual current flow. Evaluating the current of the parameterizable solid-state overload protection increases the availability of the drives, as do reliable messages concerning the overranging or underranging of setpoint values. Diagnostics and maintenance The M200D sets new standards for diagnostics. In addition to diagnostics using the PAE process image and diagnostics by "parameter echo" (up to 15 different diagnostic signals per slave can be read out via AS-i Communication), the possibility of reading out diagnostic data records is unique on the market. The AS-i Standard is recommended, in particular, for expansive and highly automated plant parts, because the possibility of monitoring devices and systems with data records (statistical data, measured values and device diagnostics) provides an indepth view of the plant from the control room, guaranteeing the monitoring process and increasing plant availability. The integrated maintenance timer can be used to implement preventative maintenance and avoid plant downtimes through look-ahead servicing. Local on-site control of a drive is possible using the ordering option with integrated manual operation. This is yet another new development which distinguishes the M200D AS-i Standard motor starter from the rest of the market and adds innovative technology, maximum availability and transparency to the plant. Siemens IK PI ews January 2010 /13
14 M200D Motor Starters for Siemens AG 2010 Overview (continued) SIRIUS M200D SIRIUS M200D AS-i Basic AS-i Standard Device functions (software features) Slave on the bus Fieldbus AS-i Slave type A/B acc. to Spec 2.1 A/B acc. to Spec 3.0 Profile 7.A.E 7.A.E & 7.A.5 umber of assigned AS-i addresses on the bus 1 2 umber of stations per AS-i master Maximum 2 devices Maximum 31 devices AS-i master profile M3 and higher M4 and higher Parameterization DIP switches -- Potentiometer for rated operational current -- ES Motor Starter -- Data records through AS-i -- Diagnostics Diagnostics through parameter channel Acyclic through data records -- Expanded process image PAE 4 bytes -- Process image Process image 4E/3A E/4A Data channels Local optical interface (manual on-site) AS-i bus Motor Starter ES through local interface -- Motor Starter ES through bus -- Data records 1) (acyclic) Parameterization -- Diagnostics -- Measured values -- Statistics -- Commands -- Inputs Qty 4 Of these in the process image 2 through AS-i 4 through AS-i Input action Permanently assigned functions, see manual Parameterizable: Flexible Quick-Stop Permanent function: latching, edge-triggered Parameterizable function: latching (edge-triggered), non-latching (level-triggered) Outputs Qty 1 Output action Permanent function: assigned with group fault Parameterizable: Function, see manual Brake output 180 V DC / 230/400 V AC / none Motor protection Overload protection Electronic, wide range 1:10 Short-circuit protection Full motor protection Temperature sensor Parameterizable using DIP switches: PTC or Thermoclick or deactivated Parameterizable using ES Motor Starter, data record: PTC or Thermoclick or deactivated Function is available; -- Function is not available. 1) The data records are a reduced selection compared with PROFIBUS/PROFIET /14 Siemens IK PI ews January 2010
15 Overview (continued) Siemens AG 2010 M200D Motor Starters for SIRIUS M200D SIRIUS M200D AS-i Basic AS-i Standard Device functions (software features) Device functions Repair switch Current limit monitoring bottom -- Parameterizable Current limit monitoring top -- Parameterizable Zero current detection Permanent function: disconnection, less than Parameterizable % of the rated operational current I e Blocking current Permanent function: Starting up of the motor: Parameterizable tripping limit at 800 % of the rated operational current I e for 10 s Active operation: threshold for tripping "blocking current" at 400 % of the rated operational current I e Unbalance Permanent function: at 30 % of the rated Parameterizable operational current I e (only mechanical MS) Load type Permanent function: three-phase Parameterizable: single- and three-phase Shutdown class Parameterizable using DIP switches: Class 10 / deactivated Parameterizable using ES Motor Starter, data record: Class 5, 10, 15, 20 Protection against voltage failure Parameterizable: Activated/deactivated Soft starter control function Soft start function -- Bypass function -- Only electronic version Function is available; -- Function is not available. Application The M200D AS-i standard is particularly suitable for highly automated applications in conveyor systems, which require that devices and plants be monitored to prevent or limit plant downtime. The option of planning the functions of the motor starter or its interfaces also makes fine-adjustment to the function of the motor starter in the application possible and hence, provides for extreme flexibility. Siemens IK PI ews January 2010 /15
16 M200D Motor Starters for Siemens AG 2010 More information Type M200D Motor Starters AS-i Basic electromechanical switching AS-i Basic electronic switching AS-i Standard electromechanical switching AS-i Standard electronic switching Technology designation 1) DSte / RSte sdste / srste DSte / RSte sdsste / srsste Mechanics and environment Mounting dimensions (W x H x D) mm 294 x 215 x 159 Permissible ambient temperature During operation C During storage C Weight g 2880 / / / / 3420 Permissible mounting position Vertical, horizontal, lying Vibration resistance acc. to IEC 008 Part 2-2 g Shock resistance Acc. to IEC 008 Part g/11 ms half-sine Without influencing the contact position Degree of protection acc. to IEC 529 Installation height Up to 1000 m Up to 2000 m 9,8 g/5 ms or 5.9 g/10 ms IP5 o derating 1 % per 100 m Cooling Convection Protection class IEC 53 (VDE 010-1) 1 Electrical specifications Control circuit Operational voltage U As-i V DC Control supply voltage U aux V DC Power consumption from AS-i (incl. 200 ma sensor supply) ma <300 Power consumption from U aux (without digital output) Max. ma (direct-on-line)/ 175 (reversing) Typ. ma (direct-on-line)/ 75 (reversing) Main circuit (direct-on-line)/ 175 (reversing) (direct-on-line)/ 75 (reversing) Maximum power of induction motors at 400 V AC kw Rated operational voltage U e Approval acc. to E V AC 400 (50/0 Hz) Approval acc. to UL and CSA V AC 00 (50/0 Hz) 480 (50/0 Hz) Rated operational current range A / / Rated operational current range for soft start A / Rated operational current range for direct start A / /1.5-9 Rated operational current for starter I e at 400 V AC 400 V - AC-1 / 2 / 3 A V - AC-1 / 2 / 3 A V - AC-4 A V AC53a A for soft starting 9 for direct-in-line starting 1) DS... Direct-on-line starter RS... Reversing starters te... Full motor protection (thermal + electronic) s... Electronic switching with semiconductor 2) Only systems with grounded neutral point permitted /1 Siemens IK PI ews January 2010
17 M200D Motor Starters for More information (continued) Type M200D Motor Starters AS-i Basic electromechanical switching AS-i Basic electronic switching AS-i Standard electromechanical switching AS-i Standard electronic switching Technology designation 1) DSte / RSte sdste / srste DSte / RSte sdsste / srsste Mechanical endurance of contactor 30 million operating cycles million operating cycles Trip class Class 10 CLASS 5, 10, 15, 20 Type of coordination acc. to IEC (2 for device 1 1 (2 for device 1 variant 2A) variant 2A) Reliable switching frequency See manual Rated ultimate short-circuit breaking capacity I q -- At 400 V AC ka 50 At 500 V AC ka 50 2) 20 2) ) Short-circuit protection At I emax = 2 A 1) DS... Direct-on-line starter RS... Reversing starters te... Full motor protection (thermal + electronic) s... Electronic switching with semiconductor 2) Only systems with grounded neutral point permitted Integrated, 2 x13 I e = 2 A At I emax = 9 /12 A Integrated, 2 x13 I e = 208 A Brake version (option) Designation 400 V/230 V AC 180 V DC 400 V/230 V AC 180 V DC Operational voltage V 400 / 230 AC DC / 230 AC DC 180 Uninterrupted current A < 0.5 < 0.8 < 0.5 < 0.8 Short-circuit protection Yes, 1 A melting fuse Siemens IK PI ews January 2010 /17
18 M200D motor starters for M200D Basic / M200D Standard motor starters Selection and ordering data Siemens AG 2010 M200D AS-i Basic without manual on-site operation M200D AS-i Basic with manual on-site operation M200D AS-i Standard Version Electromechanical starters (with integrated protection) Setting range for rated operational current / A 0, Order o. 3RK S41-7 AA 7 Direct-on-line starters/reversing starters Direct-on-line starters 0 Reversing starter 1 Direct-on-line starters with manual local operation Reversing starters with manual local operation Brake control Without brake control 0 Brake control (400 V AC) 3 Brake control (180 V DC) 5 Electronic starters (with thyristors) Setting range for rated operational current / A K L 3RK S71-7 AA 7 Direct-on-line starters/reversing starters Direct-on-line starters 0 Reversing starter 1 Direct-on-line starters with manual local operation Reversing starters with manual local operation Brake control Without brake control 0 Brake control 3 (230/400 V AC) Brake control (180 V DC) 5 K Version Electromechanical starters (with integrated protection) Setting range for rated operational current / A 0, , Order o. 3RK S41-7 AA 7 Direct-on-line starters/reversing starters Direct-on-line starters 0 Reversing starter 1 Direct-on-line starters with manual local operation Reversing starters with manual local operation Brake control Without brake control 0 Brake control (400 V AC) 3 Brake control (180 V DC) 5 Electronic starters (with thyristors) Setting range for rated operational current / A 0, , K L 3RK S71-7 AA 7 Direct-on-line starters/reversing starters Direct-on-line starters 0 Reversing starter 1 Direct-on-line starters with manual local operation Reversing starters with manual local operation Brake control Without brake control 0 Brake control 3 (230/400 V AC) Brake control (180 V DC) 5 K /18 Siemens IK PI ews January 2010
19 SIRIUS M200D motor starters Accessories Overview SA0_ M Power feeder plug Power connection plug Incoming energy supply cable Motor connection plug Motor plug Motor cable Power and motor connection on the M200D motor starter (in this example: M200D for AS-i) Communication connection using PROFIBUS and digital inputs and outputs 7 SA0_00485a SA0_00488a Connection for digital input (IO communication, 5-pole) Connection for digital output (IO communication, 4- or 5-pole) PROFIBUS connection (input) PROFIBUS connection (loop) Connection for 24 V supply (infeed) Connection for 24 V supply (loop) SA0_00487a Connection for digital input 8 10 (IO communication, 5-pole) Connection for digital output Connection for motor control with AS-i communication M12 feeder Connection for digital input (IO communication, 5-pole) Connection for digital output (IO communication, 4 or 5-pole) (IO communication, 4- or 5-pole) Connection for 24 V supply (infeed) Connection for 24 V supply (loop) Connection with PROFIET (input on the left, loop on the right) Communication connection using and digital inputs and outputs Communication connection using PROFIET and digital inputs and outputs Siemens IK PI ews January 2010 /19
20 SIRIUS M200D motor starters Accessories Selection and ordering data The accessories listed below represent a basic selection. Version Mountable accessories M200D protective brackets Incoming energy supply $ Power feeder plugs Connector set for energy supply, e.g. for connecting to T terminal connectors, comprising a coupling enclosure, straight outgoing feeder (with bracket), pin insert for HA Q4/2, incl. gland 5 male contacts 2.5 mm 2 Motor cables 5 male contacts 4 mm 2 5 male contacts mm 2 Order o. 3RK BA00 3RK BS0 3RK BS20 3RK BS40 % Power connection plugs Connector set for energy supply for connection to M200D motor starters, comprising a cable-end connector hood, angular outgoing unit, female insert for HA Q4/2, incl. gland 5 female contacts 2.5 mm 2 3RK BE50 2 female contacts 0.5 mm 2 5 female contacts 4 mm 2 3RK BE10 2 female contacts 0.5 mm 2 5 female contacts mm 2 3RK BE30 2 female contacts 0.5 mm 2 % + & Power connection cable Assembled at one end with "" and jumper pin 11 and 12 for plug monitoring, with HA Q4/2, angular; open at one end; 5 x 4 mm 2 Length 1.5 m Length 5.0 m ( Motor connection plugs Connector set for motor cable for connection to M200D motor starters, comprising a cable-end connector hood, angular outgoing feeder, pin insert for HA Q8/0, incl. gland 8 male contacts 1.5 mm 2 male contacts 2.5 mm 2 ) Motor plugs Connector set for motor cable for connection to motors, comprising a cable-end connector hood, straight outgoing feeder, female insert for HA 10e, incl. star jumper, incl. gland 7 female contacts 1.5 mm 2 7 female contacts 2.5 mm 2 3RK DC13 3RK DC33 3RK CE00 3RK CC00 3RK BM21 3RK BM22 ( + * Motor cables, assembled at one end Open at one end, HA Q8/0, angular, length 5 m Motor cables for motor with brake, for M200D, 3RK EB31 4 x 1.5 mm 2 Motor cables for motor with brake control 400 V AC or 180 V DC, x 1.5 mm 2 3RK ED31 Motor cables for motor with brake control 230 V AC or thermistor, 8 x 1.5 mm 2 3RK EE31 /20 Siemens IK PI ews January 2010
21 SIRIUS M200D motor starters Accessories Selection and ordering data (continued) Version Motor control with AS-i communication 1) 27 3RX CC42-1AF0 FS10_00341 FS10_00339 M12x1 max. Ø15 M12x1 3RX CC45 + Control cables, assembled at one end Open at one end, angular M12 cable boxes for screw fixing, degree of protection IP7, 4-pole, 4 x 0.34 mm 2 Cable length 5 m + Coupling boxes with terminal compartment, can be pre-assembled Angular M12 cable boxes for screw fixing, degree of protection IP7, 4-pole, 4 x 0.34 mm 2, M12 feeder For flat cable AS-i/ U aux, flat cable to M12 socket AS-i/ U aux, flat cable to M12 cable box, cable length 1 m AS-i/ U aux, flat cable to M12 cable box, cable length 2 m Order o. 3RX CC42-1AF0 3RX CC45 3RK R20 3RK R21 3RK R22 3RK R21 Cable terminating pieces For sealing of open cable ends (shaped cable) in IP7 3RK M00 3RK M00 Motor control with IO communication 1) max. 50 FS10_0034. Angular M12 coupler plugs Degree of protection IP 7, 5-pole, for extension cable (metal screw cap) with terminal compartment, cable let-through max. mm 3RX CE55 M12x1 Ø20 3RX CE55 FS10_00348 Ø15 max. 40 3RX CC42-1AF0. Control cables, assembled at one end Angular M12 cable plugs, degree of protection IP7, 4 x 0.34 mm 2 (metal screw cap) Length 5 m Length 10 m -,. Control cables, assembled at one end Angular M12 cable plugs, 5-pole PUR cables 1.5 m PUR cables 5 m PUR cables 10 m 3RX CE42-1AF0 3RX CE42-1AL0 3RX CE52-1AB5 3RX CE52-1AF0 3RX CE52-1AL0 1) For more plug-in connections, see Catalogs FS 10 and IK PI Siemens IK PI ews January 2010 /21
22 SIRIUS M200D motor starters Accessories Selection and ordering data (continued) Version Motor control with PROFIBUS Plugs M12 for screw fixing, angled, B coded, no terminating resistor / 5 female contacts 0 5 male contacts Control cables, assembled at one end M12 for screw fixing, angled, B coded, no terminating resistor / 5 female contacts, 3 m / 5 female contacts, 5 m / 5 female contacts, 10 m / 0 Control cables, assembled at both ends M12 for screw fixing, angled, 5-pole, B coded, no terminating resistor 3.0 m 5.0 m 10.0 m Motor control with PROFIET 3 Plugs M12 for screw fixing, angled, D coded, 4 male contacts 3. Control cables, assembled at one end M12 for screw fixing, angled, D coded, 4 male contacts, 3.0 m 4 male contacts, 5.0 m 4 male contacts, 10.0 m 3 Control cables, assembled at both ends M12 for screw fixing, angled at both ends, 4-pole, D coded, male contacts at both ends 3.0 m 5.0 m 10.0 m Connection for 24 V supply to M200D PROFIBUS / PROFIET Plugs On M200D, 7/8 for screw fixing, angled, 1.5 mm female contacts 2 5 male contacts 1 Supply lines, assembled at one end 7/8 for screw fixing, angled, 1.5 mm 2 5 female contacts, 3.0 m 5 female contacts, 5.0 m 5 female contacts, 10.0 m 1 2 Supply lines, assembled at both ends 7/8 for screw fixing, angled at both ends, 5-pole, 1.5 mm m 5.0 m 10.0 m Further accessories PROFIBUS trailing cables max. acceleration 4 m/s 2, at least bending cycles, bending radius at least 0 mm, 2-core, shielded, sold by the meter, minimum order quantity 20 m, maximum order quantity 1000 m PROFIBUS FC Food bus cables With PE outer sheath for operation in the food and beverage industry, 2-core, shielded, sold by the meter, minimum order quantity 20 m, maximum order quantity 1000 m PROFIBUS FC Robust bus cables With PUR outer sheath for operation in environments exposed to chemicals and mechanical loads, 2-core, shielded, sold by the meter, minimum order quantity 20 m, maximum order quantity 1000 m Power cables 5-core, 5 x 1.5 mm 2, trailing, sold by the meter, minimum order quantity 20 m, maximum order quantity 1000 m Order o. 3RK DA00 3RK BA00 3RK GB30 3RK GB50 3RK GC10 3RK B30 3RK B50 3RK C10 3RK DA00 3RK HB30 3RK HB50 3RK HC10 3RK B30 3RK B50 3RK C10 3RK DA00 3RK BA00 3RK GB30 3RK GB50 3RK GC10 3RK B30 3RK B50 3RK C10 XV EH10 XV GH10 XV JH10 XV AH10 /22 Siemens IK PI ews January 2010
23 SIRIUS M200D motor starters Accessories Selection and ordering data (continued) Further accessories Version PROFIET IE FC TP Standard Cable GP 2 x 2 sold by the meter PROFIET IE FC TP Trailing Cable 2 x 2 sold by the meter PROFIET IE FC TP Trailing Cable GP 2 x 2 sold by the meter PROFIET IE FC TP Torsion Cable 2 x 2 sold by the meter PROFIET IE FC TP Marine Cable, 4-core sold by the meter Hand-held devices for ET 200pro motor starter, (also for M200D, ET 200S High Feature and ECOFAST), for local operation. A serial interface cable must be ordered separately. Order o. XV AH10 XV AH10 XV D XV F XV AH10 3RK BA00 3RK BA00 3RK AB01 3RX GF32-1AB5 3RK KA00 Addressing units for AS-i add-on modules For modules and sensors and actuators with integrated Including extended addressing mode for A/B slaves For setting the AS-i address of standard slaves and A/B slaves (also for slaves according to Version 3.0) Battery operation with 4 batteries type AA (IEC LR, EDA 15) Scope of supply - 1 addressing unit - 1 operating manual (German, English, French, Spanish, Italian) - 1 addressing cable (1.5 m, with addressing plug) 3RK AB01 Addressing cable, with M12 plug to M12 socket 3RX GF32-1AB5 For addressing slaves with M12 connection, e.g. K20 or K0R modules or light curtains When using the current version of the 3RK AB01 addressing unit Length 1.5 m Dismantling tools for HA Q4/2 3RK AB00 Crimping tools for pins/sockets 4 mm 2 and mm 2 3RK CW00 Crimping tools for male contacts and sockets up to 4.0 mm 2 (HA Q8/0) 3RK CT00 Dismantling tools for male contacts and sockets (HA Q8/0) 3RK AJ00 USB interface cables, 2.5 m SL3555-0PA00-2AA0 7/8 Sealing caps ES7194-3JA00-0AA0 M12 sealing caps 3RK KA00 For sealing unused input and output sockets not for M12-AS-i connections (one set contains 10 sealing caps) RS 232 interface cables More connection technology products can be found at our "Siemens Solution Partners" under "Distributed Field Installation System" technology 3RK BP00 Siemens IK PI ews January 2010 /23
24 SIRIUS MCU motor starters General data Overview Siemens AG RK R58-0BA0 3RK R51-.BA0 3RK R51-.BA0 3RK Q54-.BA. 3RK Q4-.BA. Portfolio of the SIRIUS 3RK43 MCU motor starter family The SIRIUS MCU motor starter family (MCU = Motor Control Unit) rounds off the bottom end of the SIRIUS motor starter range. A system solution for the control of AC loads outside the control cabinet for operation in the field represents the application area for this motor starter series in a high degree of protection. The MCU product range extends from I/O-controlled motor starters addressing a central sub-distribution board via I/O stations in a plastic enclosure for simple applications to motor starters with AS-i communication in a rugged metal enclosure for demanding tasks. The MCU motor starters are completely pre-wired inside, have a high degree of protection and are designed for switching and protecting any AC loads. They are mostly used on standard induction motors in direct or reversing duty up to 5.5 kw at 400/500 V AC (electromechanical switching) and 400/40 V AC (electronic switching). The motor and short-circuit protection integrated in the MCUs consists either of an electromechanical controlgear assembly or solid-state overload protection and a motor starter protector unit for short-circuit protection. MCUs with metal enclosure are designed for the switching of induction motors. Integrated control of the electrically operated motor brake with a braking voltage of 230 V AC or 400 V AC is a standard feature. The braking voltage is routed to the motor over the motor cable. SIRIUS MCU motor starters have the following main features: Direct-on-line or reversing starters Up to 5.5 kw Plastic or metal enclosure Electromechanical or electronic switching With brake control 230 V AC or 400 V AC Integrated lockable repair switch Short-circuit protection with SIRIUS 3RV motor starter protector Overload protection with thermal release (bimetal) or solidstate overload relay with wide range setting Power and load connection by means of an M screw Main power loop possible (daisy chain; max. 2 x mm 2 ) Robust and widely used M12 connection method for the AS-i bus connection and the digital inputs and outputs (on the MCU with metal enclosure) The LEDs (for AS-i bus connection) can provide comprehensive diagnostics of the device on the spot. /24 Siemens IK PI ews January 2010
25 SIRIUS MCU motor starters General data Overview (continued) Locally controlled MCU motor starters in a plastic enclosure These motor starters are designed for the autonomous operation of any AC loads preferably induction motors. Only the infeed needs to be connected (no bus connection or any other connection to a controller). The motor is protected against short-circuits (50 ka) and overloads (thermal overload release) by the integrated motor starter protector. Similarly, there are no additional measures needed for these functions (e.g. back-up fuses). These motor starters have a key-operated switch "MA-0-AUTO" for selecting Manual, 0 or Automatic mode and preventing unauthorized changes of operating mode. In automatic mode, the motor can be controlled automatically by connected sensors (level, temperature or pressure switches). The reversing starter is designed in addition with connections for 2 sensors so a reversal of direction is possible in accordance with these sensors. On the reversing starter, the controls with interlock are pre-wired. In manual mode, a selector button is used by the operator for switching on, switching off and changing the direction of rotation. I/O-controlled MCU motor starters in a plastic enclosure These motor starters offer an economical solution for controlling induction motors distributed in the field. The internal controls (contactors) are operated by external control with 24 V DC. On the reversing starter, the controls with interlock are pre-wired. The status of the circuit breaker can be queried through its floating changeover contact. The status can adopt the following positions: activated the contact is closed and deactivated or tripped the contact is open (I/O control). MCU motor starters with AS-i bus connection in a plastic enclosure This motor starter version offers an economical solution for controlling and monitoring conveyor belts, pumps, fans or compressors. On this MCU, the control commands and the status queries are sent over the AS-i bus. The yellow cable (bus) and the black AS-i cable for 24 V DC AUX are connected through a M12 plug. The transparent enclosure top permits monitoring of the status LEDs. These MCUs come completely pre-wired inside. MCU motor starters with AS-i bus connection in a metal enclosure for electromechanical or electronic switching These MCUs with their rugged metal enclosure in degree of protection IP54 are ideal, in particular, for controlling and monitoring induction motors in harsh ambient conditions such as those often found in conveyor systems. A special feature of this version is the manual local operation of the motor starter. The key-operated switch "MA-0-AUTO" for selecting Manual, 0 or Automatic mode prevents unauthorized changes of operating mode. In automatic mode, the MCU is controlled through the AS-i bus. In manual mode, a selector button is used for switching on, switching off and changing the direction of rotation. The status/diagnostics LEDs fitted to the cover indicate the current operating state of the motor starter. Unlike the electromechanical starter, the solid-state motor starter has wear-free solid-state switching devices which guarantee a high switching frequency. Another highlight of the electronic switching version is the solidstate overload relay for motor protection, which has a wide setting range for the motor current. Siemens IK PI ews January 2010 /25
26 SIRIUS MCU motor starters General data Overview (continued) Siemens AG RK R58-0BA0 3RK R51-.BA0 3RK R51-.BA0 3RK Q54-.BA. 3RK Q4-.BA. Type Electromechanical switching Device functions (software features) Slave on the bus SIRIUS MCU Motor Starters Locally controlled I/O-controlled For For For Plastic enclosures Plastic enclosures Plastic enclosures Metal enclosures Metal enclosures Electromechanical switching Electromechanical switching Electromechanical switching Fieldbus -- AS-i Bus connection -- M12 Slave type -- AS-i Spec 2.0 A/B acc. to Spec 2.1 Profile F 7.A.0 umber of assigned -- 1 AS-i addresses on the bus umber of stations -- Maximum 31 Maximum 2 devices devices Diagnostics LEDs -- Process image Process image -- 2I/2O 4E/3A Data channels Manual local operation -- Inputs Qty 1 on the direct-online starter 2 on the reversing starter Of these in the process -- DI1 DI2 / DI3 image Connection Screw terminal, int. -- Screw terminal, int. M12 - A coded Input signal O contact -- Switching contact or 2-wire Bero Switching contact or 2/3-wire Bero Input level AC 230 V -- AS-i + Outputs Qty -- 1 on the direct-online 1 starter 0 on the reversing starter Of these in the process -- DO1 DO2 image Connection -- Screw terminal, int. M12 - A coded Output level -- Relay cont., floating AUX-PWR+ (24 V DC) Motor protection Overload protection Thermal overload release Short-circuit protection Auto reset -- Temperature sensor -- TC (Thermoclick) Device functions Response when Floating contact Signal through AS-i repair switch is tripped Plug monitoring -- Possible (with plug option) Electronic switching Electronic overload releases Wide range Function is available; -- Function is not available. /2 Siemens IK PI ews January 2010
27 SIRIUS MCU motor starters General data Benefits High degree of protection, namely IP55 on MCU motor starters in a plastic enclosure and IP54 on motor starters in a metal enclosure, enables distributed configurations in the field and saves space in the control cabinet Comprehensive motor protection thanks to integrated overload and short-circuit protection with SIRIUS 3RV motor starter protectors or integrated solid-state overload relays (solid-state starters) Wide range version (motor current) through solid-state overload relay Controlled stopping through braking control for motor brake Cable connection by means of economical M screw (optionally with plug-in connection) Simple mounting for AS-i and external auxiliary voltage (DC 24 V) over an M12 connection Status/diagnostics displays with built-in LEDs Manual operation: An integrated key-operated switch "MA-0-AUTO" and a selector button for switching on, switching off and changing the direction of rotation for control purposes during commissioning or maintenance Easy and user-friendly control and monitoring through bus communication Robust and widely used M12 connection method for digital inputs and outputs to connect I/O stations and the AS-i bus connection increase flexibility and prevent errors in the system configuration. Application Main areas of use Controlled by I/Os and AS-i bus: Airports Automotive industry Intralogistics Locally controlled Industrial, commercial and agricultural applications (for autonomously controlled motors such as pumps, fans, etc.) Siemens IK PI ews January 2010 /27
28 SIRIUS MCU motor starters General data More information Siemens AG 2010 Type SIRIUS MCU Motor Starters Locally controlled I/O-controlled For For For Plastic enclosures Plastic enclosures Plastic enclosures Metal enclosures Metal enclosures Electromechanical switching Electromechanical switching Electromechanical switching Electromechanical switching Mechanics and environment Mounting dimensions (W x H x D) mm 182 x 220 x x 215 x 205 Permissible ambient temperature During operation C max. +5 with reduction Weight g / Permissible mounting position On the wall 30, inclination ±30 Degree of protection acc. to IEC 529 IP54 IP55 IP54 Cooling Convection Electrical specifications Control circuit On the wall 30, inclination ±20 Operational voltage U As-i V DC -- 2, , Control supply voltage U aux V DC -- 20,4... 2,4 20, ,8 Control supply voltage V AC 230, from DC inside Power consumption from AS-i ma (incl. 200 ma sensor supply) Main circuit Rating for induction motor See "Selection and Ordering Data" at 400 V, 50 Hz, AC-3 Incoming energy supply M screw Motor feeder M screw Rated operational current for starter I e See "Selection and Ordering Data" at 400 V AC Trip class Class 10 Type of coordination 1 acc. to IEC Short-circuit breaking capacity I cu ka 50 at 400 V AC Brake version Operational voltage V AC or 230 Electronic switching Uninterrupted current -- Max. 5 % of I e Short-circuit protection -- Integrated /28 Siemens IK PI ews January 2010
29 MCU motor starters, locally controlled plastic enclosures, electromechanical switching Overview MCU, locally controlled, plastic enclosure For manual and automatic mode Direct-on-line or reversing starters up to 12 A at 400 V AC (50/0 Hz) Main control switch (red/yellow) Lockable with padlocks (max. 3 units) Integrated overload and short-circuit protection with SIRIUS 3RV motor starter protectors Class 10 with short-circuit breaking capacity I cu = 50 ka at 400 V AC Overload protection with thermal release (bimetal) Plastic enclosures Degree of protection IP54 Cable connections by means of M screws Main power loop possible (daisy chain; max. 2 x mm 2 ) Key-operated switch for manual/automatic mode (MA-0-AUTO) In manual mode, the user can operate the motor with the knob-operated control switch using the O function (0-O) on the direct-on-line starter or the Forwards/Reverse function (Rev-0-For) on the reversing starter. Automatic mode: Through connection of one sensor on the direct-on-line starter or 2 sensors on the reversing starter for e.g. temperature, pressure, level etc., the motor can be controlled in automatic mode by the connected sensors. 4 x M20 glands enclosed Selection and ordering data Direct-on-line starters Direct-on-line starting Reversing starter Reversing duty Rated current I e Suitable for three-phase induction motors 1) with P A kw A Main switch Key-operated switch manual/automatic mode Knob-operated switch manual mode External sensor Main energy supply by means of M screws (max. mm 2 ) Power loop-through connection possible (daisy chain) Load outgoing feeder by means of M screws MCU, locally controlled, plastic enclosure, for manual and automatic mode 7 (Feeder positions only examples - feeders can be laid in all directions) Setting range Thermal overload release Order o RK CR58-0BA RK DR58-0BA RK ER58-0BA RK FR58-0BA RK HR58-0BA RK JR58-0BA RK LR58-0BA RK MR58-0BA RK R58-0BA RK PR58-0BA RK CR58-1BA RK DR58-1BA RK ER58-1BA RK FR58-1BA RK HR58-1BA RK JR58-1BA RK LR58-1BA RK MR58-1BA RK R58-1BA RK PR58-1BA0 nsb0_ ) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. Siemens IK PI ews January 2010 /29
30 MCU motor starters, I/O-controlled plastic enclosures, electromechanical switching Overview MCU, I/O-controlled, plastic enclosure Direct-on-line or reversing starters up to 12 A at 400 V AC (50/0 Hz) Repair switches (black/gray) lockable with padlocks (max. 3 units) Integrated overload and short-circuit protection with SIRIUS 3RV motor starter protectors Class 10 with short-circuit breaking capacity I cu = 50 ka at 400 V AC Overload protection with thermal release (bimetal) Plastic enclosures Degree of protection IP55 Cable connections by means of M screws Main power loop possible (daisy chain; max. 2 x mm 2 ) Control circuit: I/O-wiring; control inputs 24 V DC 4 x M20 glands enclosed 1 1 Main control switch / repair switch 2 Control inputs (24 V DC) 3 Load outgoing feeder through M screw 4 Main incoming power supply through M screw (max. mm 2 ) 5 Main power loop possible (daisy chain) (position of outgoing units as example outgoing units are possible on all sides) nsb0_ MCU, I/O-controlled, plastic enclosure Selection and ordering data Direct-on-line starters Direct-on-line starting Reversing starter Reversing duty Rated current I e Suitable for three-phase induction motors 1) with P A kw A Setting range Thermal overload release Order o RK AR51-0BA RK BR51-0BA RK CR51-0BA RK DR51-0BA RK ER51-0BA RK FR51-0BA RK GR51-0BA RK HR51-0BA RK JR51-0BA RK KR51-0BA RK LR51-0BA RK MR51-0BA RK R51-0BA RK PR51-0BA RK AR51-1BA RK BR51-1BA RK CR51-1BA RK DR51-1BA RK ER51-1BA RK FR51-1BA RK GR51-1BA RK HR51-1BA RK JR51-1BA RK KR51-1BA RK LR51-1BA RK MR51-1BA RK R51-1BA RK PR51-1BA0 1) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. /30 Siemens IK PI ews January 2010
31 MCU motor starters for plastic enclosures, electromechanical switching Overview MCU for AS-i, plastic enclosure Direct-on-line or reversing starters up to 12 A at 400 V AC (50/0 Hz) Repair switches (black/gray) lockable with padlocks (max. 3 units) Integrated overload and short-circuit protection with SIRIUS 3RV motor starter protectors Class 10 with short-circuit breaking capacity I cu = 50 ka at 400 V AC Overload protection with thermal release (bimetal) Transparent plastic enclosure with LED status displays for monitoring the AS-i status Degree of protection IP55 Cable connections by means of M screws Main power loop possible (daisy chain; max. 2 x mm 2 ) through M12 plug-in terminal 4 x M20 glands enclosed Communication: 2I/2O (standard slaves) 1 1 Main control switch / repair switch 2 Load outgoing feeder through M screw 3 Main incoming power supply through M screw (max. mm 2 ) 4 Main power loop possible (daisy chain) 5 AS-i communication / U aux (24 V DC) through M12 plug (position of outgoing units as example outgoing units are possible on all sides) MCU for AS-i, plastic enclosure nsb0_ Selection and ordering data Direct-on-line starters Direct-on-line starting Reversing starter Reversing duty Rated current I e Suitable for three-phase induction motors 1) with P A kw A Setting range Thermal overload release Order o RK AR51-0BA RK BR51-0BA RK CR51-0BA RK DR51-0BA RK ER51-0BA RK FR51-0BA RK GR51-0BA RK HR51-0BA RK JR51-0BA RK KR51-0BA RK LR51-0BA RK MR51-0BA RK R51-0BA RK PR51-0BA RK AR51-1BA RK BR51-1BA RK CR51-1BA RK DR51-1BA RK ER51-1BA RK FR51-1BA RK GR51-1BA RK HR51-1BA RK JR51-1BA RK KR51-1BA RK LR51-1BA RK MR51-1BA RK R51-1BA RK PR51-1BA0 1) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. Siemens IK PI ews January 2010 /31
32 MCU motor starters for metal enclosures, electromechanical switching Overview MCU for AS-i, metal enclosure, electromechanical Direct-on-line or reversing starters up to 12 A Repair switches (black/gray) lockable with padlocks (max. 3 units) Short-circuit protection with SIRIUS 3RV motor starter protectors Class 10 with short-circuit breaking capacity I cu = 50 ka at 400 V AC Overload protection with thermal release (bimetal) Manual operation and key-operated switch for operating mode selection LED status display of the operating states Metal enclosures Degree of protection IP54 Switched brake control 400 V or 230 V Cable connections by means of M screws Main power loop possible (daisy chain; max. 2 x mm 2 ) 2 x M25 glands 1 x M12 plug for AS-i/auxiliary voltage (24 V DC) 2 M12 socket for connection of 2 sensors 1 M12 socket for connection of one actuator Communication: 4I/3O (slaves in A/B technology can be addressed) Main control switch / repair switch Main incoming power supply (400 V AC) through M screw AS-i communication / U aux (24 V DC) through M12 plug 2 sensor inputs (M12 socket), 1 actuator output (M12 socket) LED status displays of the operating states Key-operated switch: Manual-0-Auto Manual operation: O/OFF or Left-0-Right (selector button) Load outgoing feeder through M screw MCU for AS-i, metal enclosure, electromechanical switching nsb0_ /32 Siemens IK PI ews January 2010
33 MCU motor starters for metal enclosures, electromechanical switching Selection and ordering data Direct-on-line starters Direct-on-line starting Reversing starter Reversing duty Rated current I e Suitable for three-phase induction motors 1) with P A kw A Setting range Thermal overload release Order o RK AQ54-0BA RK BQ54-0BA RK CQ54-0BA RK DQ54-0BA RK EQ54-0BA RK FQ54-0BA RK GQ54-0BA RK HQ54-0BA RK JQ54-0BA RK KQ54-0BA RK LQ54-0BA RK MQ54-0BA RK Q54-0BA RK PQ54-0BA 7 Brake control / V RK AQ54-1BA RK BQ54-1BA RK CQ54-1BA RK DQ54-1BA RK EQ54-1BA RK FQ54-1BA RK GQ54-1BA RK HQ54-1BA RK JQ54-1BA RK KQ54-1BA RK LQ54-1BA RK MQ54-1BA RK Q54-1BA ,5 3RK PQ54-1BA 7 Brake control / V ) Guide value for 4-pole standard motors at 50 Hz 400 V AC. The actual starting and rated data of the motor to be protected must be considered when selecting the units. Siemens IK PI ews January 2010 /33
34 MCU motor starters for metal enclosures, electronic switching Overview MCU for AS-i, metal enclosure, electronic Direct-on-line or reversing starters up to 12 A Switching frequency up to 300/h Repair switches (black/gray) lockable with padlocks (max. 3 units) Short-circuit protection with SIRIUS 3RV motor starter protector Overload protection with solid-state overload relay Manual operation and key-operated switch for operating mode selection LED status display of the operating states Metal enclosures Degree of protection IP54 Switched brake control 400 V or 230 V Cable connections by means of M screws Main power loop possible (daisy chain; max. 2 x mm 2 ) 2 x M25 glands 1 x M12 plug for AS-i/auxiliary voltage (24 V DC) 2 M12 plugs for connection of 2 sensors 1 M12 socket for connection of one actuator Communication: 4I/3O (slaves in A/B technology can be addressed) Main control switch / repair switch 2 Main incoming power supply (400 V AC) through M screw 3 AS-i communication / U aux (24 V DC) through M12 plug 4 2 sensor inputs (M12 socket), 1 actuator output (M12 socket) 5 LED status displays of the operating states Key-operated switch: Manual-0-Auto 7 Manual operation: O/OFF or Left-0-Right (selector button) 8 Load outgoing feeder through M screw 9 Heat sink MCU for AS-i, metal enclosure, electronic switching nsb0_02041 Selection and ordering data Direct-on-line starters Direct-on-line starting Rating for induction motor Rated value 1) Set current value of the inverse-time delayed overload release I e kw A V Brake control Order o RK DQ4-0BA RK JQ4-0BA RK PQ4-0BA RK DQ4-0BA RK JQ4-0BA RK PQ4-0BA3 Reversing starter RK DQ4-1BA RK JQ4-1BA RK PQ4-1BA RK DQ4-1BA3 Reversing duty RK JQ4-1BA RK PQ4-1BA3 1) Guide value for 4-pole standard motors at AC 50 Hz 400 V. The actual starting and rated data of the motor to be protected must be considered when selecting the units. /34 Siemens IK PI ews January 2010
35 SIRIUS MCU motor starters Accessories Overview The MCU motor starters are equipped with standardized interfaces for data and energy (option). See also Catalog LV 1 for the field and energy bus methods for decentral installation in a high degree of protection. Siemens AG 2010 Connection technology products coordinated with the SIRIUS MCU motor starters can be found at our "Siemens Solution Partners" under "Distributed Field Installation System" technology. Siemens IK PI ews January 2010 /35
36 Slaves SIAMICS G110D distributed inverters SIAMICS G110D distributed inverters Siemens AG 2010 Overview The new SIAMICS G110D distributed frequency inverter series is the solution for basic drive tasks especially in the field of conveyor systems. The inverter allows the speed of three-phase asynchronous motors to be continually controlled and fulfills the requirements of conveyor-related applications with open-loop frequency control. It can be optimally integrated into the system thanks to its compact and low-profile design in an IP5 degree of protection. This drive can be optimally integrated into the Siemens TIA world of automation via. With its wide power range from 0.75 kw to 7.5 kw (1.0 hp to 10 hp), it is suitable for a wide range of distributed drive solutions. Example: SIAMICS G110D frame size FSA Reasons for using distributed drive systems Modular drive solutions therefore standardized mechatronic elements that can be individually tested A control cabinet is not required, resulting in a smaller space requirement and lower cooling requirements Long cables between the inverter and motor can be avoided (which means lower power losses, reduced noise emission and lower costs for shielded cables and additional filters) Distributed configurations offer considerable benefits for conveyor systems with their extensive coverage (e.g. in the automotive and logistics sectors Siemens family of distributed drives Siemens offers an innovative portfolio of frequency inverters to optimally implement distributed drive solutions. The strengths of the individual members of the drive family permit simple adaptation to the widest range of application demands: Identical connection systems Identical mounting dimensions for SIAMICS G110D and SIAMICS G120D Standard commissioning and configuration tool Products from the family of distributed drives: SIAMICS G110D frequency inverters SIAMICS G120D frequency inverters SIMATIC ET 200S FC drive converters SIMATIC ET 200pro FC drive converters SIRIUS M200D motor starters Device design SIAMICS G110D is a compact inverter in IP5 degree of protection where the Control Unit (CU) and Power Module (PM) function units are combined in one device. The closed-loop control electronics controls and monitors the power electronics in several different control types that can be selected. The digital inputs and analog inputs on the device mean that sensors can be simply and directly connected at the drive. The input signals can either be directly linked within the closed-loop control or they can be transferred to the central control via for further processing within the context of the overall system. The power electronics supplies the motor in the power range 0.75 kw to 7.5 kw (1.0 hp to 10 hp). It is controlled (open-loop) from the microprocessor-based control. State-of-the-art IGBT technology with pulse-width-modulation is used for highly reliable and flexible motor operation. It also features an extensive range of functions offering a high degree of protection for the inverter and motor. The unusually low profile mechanical design is optimized so that the device can be directly used in the plant or system. The compact inverter has the same drilling dimensions for all of the power ratings (standard footprint ); further, the dimensions are identical to those of the SIAMICS G120D frequency inverter. This significantly simplifies the mechanical design and retrofitting of the system. The latest technical documentation (catalogs, dimensional drawings, certificates, manuals and operating instructions), are available on the Internet under: and offline on the DVD CA 01 in the SD Configurator. In addition,the SD Configurator can be used on the Internet without requiring any installation. The SD Configurator can be found in the Siemens Mall under the following address: STARTER commissioning tool The STARTER commissioning tool (from STARTER Version and higher) supports the commissioning and maintenance of SIAMICS G110D inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily. /3 Siemens IK PI ews January 2010
37 Slaves SIAMICS G110D distributed inverters SIAMICS G110D distributed inverters Benefits 7 Wide power range from 0.75 kw to 7.5 kw (1.0 hp to 10 hp) 7 Fast commissioning and maintenance as well as extended diagnostic functions and communications capability with AS interface according to specification Reduced number of interfaces - Plantwide engineering - Easy to handle 7 Mechanical design, installation and retrofit of systems are significantly simplified as a result of the compact and spacesaving design with an extremely low profile and with the same drilling dimensions for all power ratings; further, the dimensions are identical with those of the SIAMICS G120D inverter. 7 Simple commissioning and maintenance using the same, standardized connectors for the bus, power and I/O connections (ISO 23570) for the complete power range of SIAMICS G110D and SIAMICS G120D inverters. 7 The same connectors are used as for the SIRIUS M200D motor starter 7 Simple, standard implementation of completely distributed plant and system concepts by using products in a scalable fashion: - SIRIUS M200D (motor starter) - SIAMICS G110D (inverter for basic, conveyor-related applications) - SIAMICS G120D (inverter for sophisticated, conveyorrelated applications) 7 High degree of operator friendliness by using the Intelligent Operator Panel (IOP) to parameterize, diagnose, control (open-loop) and copy drive parameters in the IOP 7 Easy to replace using a plug-in design and the use of a memory card provides the highest degree of service friendliness 7 Simple connection, configuration, data management as well as control of the inverter in complex plants and systems as a result of the consequential integration in TIA (Totally Integrated Automation) 7 Using the optional maintenance switch, the inverter can be simply disconnected from the line supply when service is required, without any additional components or without additional wiring costs when configuring the system 7 Using the optional manual local control, commissioning is fast and can be limited to specific areas, the application can be manually pre-tested on site and the system can be cleared or emptied without requiring complex options. 7 By being able to connect up to five sensors directly at the unit, practically all of the drive-relevant information can be directly managed; local pre-processing of the signals relieves the fieldbus to achieve fast and reproducible response times 7 Integrated class A EMC filter (acc. to E 55011) 7 Integrated brake control, brake voltages that are supported, 400 V AC/180 V DC and 230 V AC/205 V DC 7 Integrated motor protection using a thermal motor model and evaluation of PTC, Thermo-Click or KTY 84 temperature sensors 7 Simple device replacement and fast copying of parameters to the memory card using the optional memory card holder and the optional MMC memory card 7 Engineering and commissioning using standard engineering tools such as SIZER (from Version 3.2 and higher), STARTER (from Version and higher) and Drive ES ensures fast configuration and simple commissioning STARTER is integrated into STEP 7 with Drive ES Basic, with all of the benefits of central data management and unified communication 7 Software parameters for simple adaptation to 50 Hz or 0 Hz motors (IEC or EMA motors) 7 Increased degree of ruggedness and longer service life as the electronic modules are coated 7 Globally certified acc. to CE, UL, c-tick Application SIAMICS G110D is ideally suited for basic conveyor system applications in the industrial environment for which a distributed drive with communications capability is required. This is especially true for distribution logistics and for airports. Further, SIAMICS G110D is suitable for many additional lowperformance applications in many sectors, e.g. in the automobile sector, in the food and beverage industry (without tenside) and in the packaging industry. Selection and ordering data Rated power 1) Rated Input current Frame size SIAMICS G110D output current 2) with integrated Class A line filter 1) Rated power based on the rated output current I rated. The rated output current I rated is based on the duty cycle for high overload (HO). 2) The rated output current I rated is based on the duty cycle for high overload (HO). These current values are valid for 400 V and are stamped on the rating plate. 3) With the exception of UL operation, 500 V +10 % is possible. 4) It is not possible to make any assignment to a particular standard. SIAMICS G110D with integrated Class A line filter and integrated maintenance switch kw hp A A Order o. Order o V 3AC 3) FSA SL3511-0PE17-5AM0 SL3511-1PE17-5AM ) FSA SL3511-0PE21-5AM0 SL3511-1PE21-5AM FSA SL3511-0PE23-0AM0 SL3511-1PE23-0AM FSB SL3511-0PE24-0AM0 SL3511-1PE24-0AM FSC SL3511-0PE25-5AM0 SL3511-1PE25-5AM FSC SL3511-0PE27-5AM0 SL3511-1PE27-5AM0 More information More information regarding technical specifications, accessories and ordering data can be found in Catalog D 11.1 "SIAMICS G110D distributed inverters 0.75 kw to 7.5 kw" and online in the Siemens Industry Mall. Siemens IK PI ews January 2010 /37
38 Slaves 3SF5 pushbutton units and indicator lights enclosures with standard fittings Siemens AG 2010 Overview Enclosures with standard fittings are available with: 7 1 to 3 command points 7 Operational voltage through (approx. 30 V) 7 Vertical mounting type 7 Plastic enclosures are equipped with plastic actuators and indicators, metal enclosures are equipped with metal actuators and indicators. The actuators/indicators are fixed with an enclosure nut. If required it can be disassembled with a 27 mm socket wrench or with a 3SX17 07 ring nut wrench. The enclosures without EMERGECY-STOP each have one user module with 4I/3O; the enclosures with EMERGECY-STOP have a safe slave integrated in the enclosure. EMERGECY-STOP enclosures are fitted with two C contact blocks, which are wired to the safe slave. The contact blocks and lampholders (with spring-type terminals) of the control device, and the slaves, are mounted in the base of the enclosure and are cable-connected. The plastic versions of the enclosures have a connection for the flat cable (the cable is routed past the enclosure on the outside); in the case of the metal versions the cable is routed into the enclosure. The EMERGECY-STOP enclosures can also be supplied with an M12 connector in place of the gland. Selection and ordering data 3SF AA08 3SF DA00 3SF AB08 3SF DA00 Version Order o. enclosures, plastic, with standard fittings Equipment (A, B, C = identification letters of the Enclosure top umber of command positions) command points With M12 top connector A = EMERGECY-STOP mushroom pushbuttons, Yellow 1 3SF AA10 1 C, 1 C With terminal for insulation piercing method at top A = EMERGECY-STOP mushroom pushbuttons, Yellow 1 3SF AA08 1 C, 1 C A = EMERGECY-STOP mushroom pushbuttons, 1 C, 1 C B = Pushbutton green, 1 O, label "I" A = Pushbutton red, 1 O, label "O" B = Pushbutton white, 1 O, label "I" A = Pushbutton black, 1 O, label "O" C = Indicator light clear, label without inscription B = Pushbutton green, 1 O, label "I" A = Pushbutton red, 1 O, label "O" C = Indicator light clear, label without inscription B = Pushbutton white, 1 O, label "I" A = Pushbutton black, 1 O, label "O" C = Pushbutton black, 1 O, label "II" B = Pushbutton black, 1 O, label "I" A = Pushbutton red, 1 O, label "O" Yellow, with 1 3SF AB08 protective collar Gray 2 3SF DA00 Gray 2 3SF DB00 Gray 3 3SF DA00 Gray 3 3SF DC00 Gray 3 3SF DB00 enclosures, metal, with standard fittings Equipment (A, B, C = identification letters of the command positions) Enclosure top umber of command points With M12 top connector A = EMERGECY-STOP mushroom pushbuttons, 1 C, 1 C Yellow 1 3SF AA10 A = EMERGECY-STOP mushroom pushbuttons, 1 C, 1 C With cable gland at top A = EMERGECY-STOP mushroom pushbuttons, 1 C, 1 C A = EMERGECY-STOP mushroom pushbuttons, 1 C, 1 C B = Pushbutton green, 1 O, label "I" A = Pushbutton red, 1 O, label "O" B = Pushbutton white, 1 O, label "I" A = Pushbutton black, 1 O, label "O" C = Indicator light clear, label without inscription B = Pushbutton green, 1 O, label "I" A = Pushbutton red, 1 O, label "O" C = Indicator light clear, label without inscription B = Pushbutton white, 1 O, label "I" A = Pushbutton black, 1 O, label "O" C = Pushbutton black, 1 O, label "II" B = Pushbutton black, 1 O, label "I" A = Pushbutton red, 1 O, label "O" Yellow, with 1 3SF AB10 protective collar Yellow 1 3SF AA08 Yellow, with 1 3SF AB08 protective collar Gray 2 3SF DA00 Gray 2 3SF DB00 Gray 3 3SF DA00 Gray 3 3SF DC00 Gray 3 3SF DB00 3SF DA00 /38 Siemens IK PI ews January 2010
Industrial Communication
Industrial Communication / AS-Interface System overview /5 - Transmission technology /6 - Configuration examples /7 - Communication overview Slaves Contactors and contactor assemblies for AS-Interface
Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.
The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion
SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents
Preface, Contents SIMATIC NET AS-Interface - Introduction and Basics Manual AS-Interface (AS-i) 1 AS- Interface Safety at Work (ASIsafe) 2 AS-i System Components 3 The Master Mode - Commands, Sequence,
Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING
Safety along the complete line: 3SE7 cable-operated switches sirius COMMANDING & SIGNALING Everything well under control. 3SE7 cable-operated switches With cable-operated switches from our 3SE7 product
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
3 3RG78 45 program overview
Overview RG78 45 light curtains and arrays with integrated processing unit for type 4 in accordance with IEC/EN 61496 With "Standard" function package Resolutions: 14, 0, 50, and 90 Protective zone height:
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Number 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why
RoHS. Shock / vibration resistant. Magnetic field proof. Many variants
Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Safety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.
SITOP power supply Technical data SITOP Power Supply Answers for industry. Selection table SITOP power supplies Input voltage Output current modular smart LOGO!Power Special design, SIMATIC design Others
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University
Practical steps for a successful PROFIBUS Project Presented by Dr. Xiu Ji Manchester Metropolitan University Basics of PROFIBUS Content Practical steps in the design and installation stages Segmentation:
SAFETY LIGHT CURTAINS
SAFETY LIGHT CURTAINS Overview Safety Light Curtains with resolutions that can be reduced guarantee protection and tolerate work equipment in the protective field The Safety Light Curtains comply with
14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
What ensures easy and fast wiring?
What ensures easy and fast wiring? SIMATIC TOP connect: the system cabling for connecting sensors and actuators to SIMATIC S7. Answers for industry. More efficient cabling made easy: SIMATIC TOP connect
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Control Circuit Components AS-Interface, IO Link
Control Circuit Components AS-Interface, IO Link Siemens complete AS-Interface offering is found in Section 6 of the Siemens IK PI 01 Catalog. In this section you will find the Table of Contents for Section
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
SENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
RFID systems. Communications modules ASM 450 4/139. Overview
Overview The low-cost communications module ASM 50 is an autonomous PROFIBUS DP slave for the operation of MOBY components via the PROFIBUS DP: SIMATIC S7 (including FB/FC software) SINUMERIK SICOMP IMC,
Automation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space
PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Siemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.
Fieldbus solutions with the SIMATIC PCS 7 distributed control system Brochure April 2010 SIMATIC PCS 7 Answers for industry. Fieldbus solutions with SIMATIC PCS 7 OS multi-clients Engineering station Maintenance/
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
CONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
BETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
New XUY roller sensors
Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
Simple. Intelligent. The SIMATIC VS 100 Series. simatic MACHINE VISION. www.siemens.com/machine-vision
Simple. Intelligent. The SIMATIC VS 100 Series. simatic MACHINE VISION www.siemens.com/machine-vision simatic Intelligence that pays off In answer to the problem of steadily increasing clock-pulse rates
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu
INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016 Your partner in an automated industry Our combination of technical know-how, product responsibility and on-time deliveries guarantees you the best WHY CHOOSE
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
instabus KNX / EIB System System E F G H
Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Controls Solid-State Switching Devices
Controls Solid-State Switching Devices Introduction Overview 3RF21 3RF20 3RF23 3RF29 SIRIUS SC solid-state switching devices Solid-state relays 22.5 mm solid-state relays, 5 mm solid-state relays Solid-state
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
SIMATIC Safety Workshop
Experience the fast and easy way to safe machines at highest productivity Unrestricted Siemens Industry, Inc. 2014-2015 All rights reserved. - Agenda Introduction Why Machine Safety? Why Safety PLC s?
Industrial Bar Code Scanners
DS2100N & DS2400N Industrial Bar Code Scanners Enhanced Connectivity Ease of use Configuration SW Tool ACR-Lite APPLICATIONS Small conveyor sorting Picking systems Items and parts tracking Process control
Plug-in relays Mini ISO relays
Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of
CONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01
SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal
W150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping