BRITISH STANDARD LOW VOLTAGE FUSE LINKS
|
|
|
- Curtis Mitchell
- 9 years ago
- Views:
Transcription
1 BRITISH STANDARD LOW VOLTAGE FUSE LINKS
2 WORLD-WIDE CIRCUIT PROTECTION SOLUTIONS Bussmann manufacture a wide range of products for the protection of electrical and electronic circuits...fuse Links, Fuse Holders, and Fusegear, all readily available from manufacturing sites in the United Kingdom, Denmark, United States, Brazil, India and Mexico. Bussmann is a division of Cooper Industries Inc., a diversified world-wide manufacturer of electrical products and power equipment. Bussmann has grown through both organic growth and acquisition. Acquisitions have included the fusegear division of Lauritz Knudsen (LK-NES), Beswick which added UK Domestic fuses as well as IEC and UL Electronic fuses, Hawker Fusegear (formerly Brush Fusegear Ltd) which strengthened our range of power fuses and Fusegear. Bussmann circuit protection solutions comply with major international standards: BS, IEC, DIN, UL, CSA...Our manufacturing operations have earned ISO 9000 certification, ensuring the utmost quality across every product.
3 CONTENTS LOW VOLTAGE FUSE LINKS TO BS88 & IEC 269 Offset Bolted Tag 1-2 Centre Bolted Tag 3-5 Offset Bladed Tag 6 660/690V Offset Bolted Tag 7 660/690V Centre Bolted Tag /690V Special Tag Arrangement /690V Special Offset Tag 11 Special 500V dc Range 12 HOUSE SERVICE CUT OUT & J TYPE FUSE LINKS Fuse Links to BS J Type Fuse Links to BS88: Part 5 13 Fuse Links to BS88: Part 5 J Type 14 Fuse Links to BS88: Part 5 15 JOINT SERVICE & NATO FUSE LINKS DEF Standard (NATO Reference System) 16 DIMENSIONAL DATA LOW VOLTAGE FUSE LINKS TO BS88 & IEC269 Dimensional Data Offset Bolted Tag 17 Dimensional Data Centre Bolted Tag 18 Dimensional Data 660V Offset Bladed Tag 19 Dimensional Data 660V Centre Bolted Tag 19 Dimensional Data 660V Special Tag Range 20 Dimensional Data Special 500V dc Range 20 DIMENSIONAL DATA LOW VOLTAGE FUSE LINKS TO BS1361, BS88 & IEC269 Dimensional Data House Service Feeder Piller Fuse Links 21 DIMENSIONAL DATA LOW VOLTAGE FUSE LINKS TO DEFENCE STANDARD Dimensional Data for Joint Service Fuse Links 22 APPLICATION DATA BRITISH STANDARD LOW VOLTAGE INDUSTRIAL FUSE LINKS Application Information 23 Technical Data Comparison Chart 27 CAMASTER HRC FUSE HOLDERS Introduction 28 CAMASTER HRC FUSE HOLDERS Ratings, catalogue Numbers & Dimensions 29 SAFELOC HRC FUSE HOLDERS Introduction 30 SAFELOC HRC FUSE HOLDERS Ratings, catalogue Numbers & Dimensions 31 USEFUL TELEPHONE NUMBERS: Burton Product Sales Tel: +44 (0) Fax: +44 (0) Export Orders Tel: +44 (0) Fax: +44 (0) Applications Engineers Tel: +44 (0) or Fax: +44 (0) Catalogue Requests Tel: +44 (0) Fax: +44 (0) [email protected] WORLD WIDE WEB: // Please contact Bussmann for a faxed copy of our internal telephone list to enable you to direct dial the person you wish to speak to The sales desk is open from hrs until hrs GMT
4 Low Voltage Fuse Links to BS88 & IEC269 Offset Bolted Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity SMD2 2 SMD4 4 SMD6 6 SMD8 8 SMD10 10 SMD16 16 SMD20 20 SMD25 25 SMD Vac 20 pcs STD2 2 STD4 4 STD6 6 STD Vac ka 240 Vac 20 pcs Vac 20 pcs STD16 16 STD20 20 STD25 25 STD32 32 BS Ref A1 NITD2 2 NITD4 4 NITD6 6 NITD NITD16 16 NITD Vac Vac 20 pcs NITD Vac 20 pcs NITD32 32 NITD20M25 20M25 NITD20M32 20M32 NITD32M40 32M NITD32M50 32M50 NITD32M63 32M63 SEE PAGE 30 FOR FUSE HOLDERS BS Ref A2 AAO2 2 AAO4 4 AAO6 6 AAO10 10 AAO16 16 AAO Vac ka Vac 20 pcs AAO25 25 AAO32 32 AAO32M40 32M40 AAO32M50 32M50 AAO32M63 32M63 SEE PAGE 30 FOR FUSE HOLDERS 1 For more information visit our website at
5 Low Voltage Fuse Links to BS88 & IEC269 Offset Bolted Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity BS Ref A3 BAO35 35 BAO40 40 BAO50 50 BAO63 63 BAO63M80 63M80 BAO63M100 63M Vac 20 pcs SEE PAGE 30 FOR FUSE HOLDERS BS Ref A4 CEO32 32 CEO40 40 CEO50 50 CEO63 63 CEO80 80 CEO CEO100M M125 CEO100M M160 CEO100M M Vac 10 pcs OSD80 80 OSD OSD100M M125 OSD100M M Vac 20 pcs SEE PAGE 30 FOR FUSE HOLDERS DEO DEO DEO DEO200M M250 DEO200M M Vac 5 pcs For more information visit our website at 2
6 Low Voltage Fuse Links to BS88 & IEC269 Centre Bolted Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity AC2 2 AC4 4 AC6 6 AC10 10 AC16 16 AC20 20 AC25 25 AC ka Vdc AD2 2 AD4 4 AD6 6 AD10 10 AD16 16 AD20 20 AD25 25 AD Vac ka Vdc BC40 40 BC50 50 BC63 63 BC63M80 63M80 BC63M100 63M ka Vdc BD40 40 BD50 50 BD ka Vdc BS Ref B1 CD80 80 CD CD100M M125 CD100M M160 CD100M M Vac 10 pcs BS Ref B2 DD DD DD DD200M M250 DD200M M Vac 5 pcs 3 For more information visit our website at
7 Low Voltage Fuse Links to BS88 & IEC269 Centre Bolted Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity BS Ref B3/B4 ED ED ED ED ED315M M400 ED400M M Vac 1 pc 550 EFS EFS EFS EFS EFS Vac 1 pc 133 / 184 BS Ref C1 EF EF EF400M M / Vac 1 pc BS Ref C2 FF FF FF FF / ka ka 550 Vac Vdc FG FG FG FG / ka ka 550 Vac Vdc For more information visit our website at 4
8 Low Voltage Fuse Links to BS88 & IEC269 Centre Bolted Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity GG GG GG GG / ka Vac Vac 1 pc / 250 Vdc BS Ref C3 GF GF / ka ka 550 Vac Vdc GH GH GH GH Vac 1 pc 5 For more information visit our website at
9 Low Voltage Fuse Links to BS88 & IEC269 Offset Bladed Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity BS Ref E1 SSD2 2 SSD4 4 SSD6 6 SSD10 10 SSD16 16 SSD20 20 SSD25 25 SSD Vac 20 pcs BS Ref F1 NSD2 2 NSD4 4 NSD6 6 NSD10 10 NSD16 16 NSD20 20 NSD25 25 NSD32 32 NSD20M25 20M25 NSD20M32 20M32 NSD20M36 20M36 NSD32M36 32M36 NSD32M40 32M40 NSD32M50 32M50 NSD32M63 32M Vac 20 pcs SEE PAGE 31 FOR FUSE HOLDERS BS Ref F2 ESD2 2 ESD4 4 ESD6 6 ESD10 10 ESD16 16 ESD20 20 ESD25 25 ESD32 32 ESD40 40 ESD50 50 ESD63 63 ESD63M80 63M80 ESD63M100 63M Vac 20 pcs 415 SEE PAGE 31 FOR FUSE HOLDERS For more information visit our website at 6
10 Low Voltage Fuse Links to BS88 & IEC /690V Offset Bolted Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity BS Ref A2 2H H H H H H H H / ka ka 660 Vac Vdc BS Ref A3 40K K K / ka ka 660 Vac Vdc BS Ref A4 80L L / ka 660 ka Vac Vdc 125M M M / ka 660 ka Vac Vdc 7 For more information visit our website at
11 Low Voltage Fuse Links to BS88 & IEC /690V Centre Bolted Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity 2K K K K K K K K K K / ka ka 660 Vac Vdc 2K K K K K K K K K K / ka ka Vdc BS Ref B1 80L L / ka 660 ka Vac Vdc BS Ref B2 125M M M / ka 660 ka Vac Vdc BS Ref B3 250N N / ka 660 ka Vac Vdc For more information visit our website at 8
12 Low Voltage Fuse Links to BS88 & IEC /690V Centre Bolted Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity BS Ref B4 355P P / ka ka 660 Vac Vdc 125N N N N N / ka 660 ka Vac Vdc BS Ref C1 355P P / / ka 660 ka Vac Vdc BS Ref C2 450R R R R / / ka 660 ka Vac Vdc 450R R R R / / ka 660 ka Vac Vdc 9 For more information visit our website at
13 Low Voltage Fuse Links to BS88 & IEC /690V Special Tag Arrangement Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity 125M M M / ka ka 660 Vac Vdc 125M M M / ka 660 ka Vac Vdc 250N N / ka 660 ka Vac Vdc 250N N / ka 660 ka Vac Vdc 355P P / / ka 660 ka Vac Vdc 450R R / / ka 660 ka Vac Vdc For more information visit our website at 10
14 Low Voltage Fuse Links to BS88 & IEC /690V Special Offset Tag Current Rated Voltage Rated Voltage Fixing Centres Interrupting Box Rating (ac) (dc) (mm) Rating Quantity 125N N N N N / ka ka 660 Vac Vdc 355P P / ka 660 ka Vac Vdc 450R R R R / ka 660 ka Vac Vdc 710S S ka 660 ka Vac 1 pc 11 For more information visit our website at
15 Low Voltage Fuse Links to BS88 & IEC269 Special 500V dc Range Current Rated Voltage Fixing Centres Interrupting Box Rating (dc) (mm) Rating Quantity 10HS HS HS HS HS Vdc 20 pcs 40KS KS Vdc 20 pcs 63KS KS KS Vdc 20 pcs 63KS KS KS KS KS KS KS KS KS Vdc 20 pcs For more information visit our website at 12
16 House Service Cut Out & J Type Fuse Links Fuse Links to BS1361 Current Rated Voltage Interrupting Box Rating (ac) Rating Quantity 5KR KR KR KR KR KR KR KR KR KR KR KR85 80 * 90KR85 90 * 100KR LR LR LR LR LR LR LR Vac 20 pcs Vac 20 pcs * Check suitability of fuse holders before inserting these fuse links. Not for UK Applications. J Type Fuse Links to BS88: Part 5 Current Rated Voltage Interrupting Box Rating (ac) Rating Quantity 20MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ Vac 10 pcs 13 For more information visit our website at
17 J Type Fuse Links for Low Voltage Feeder Piller Protection Fuse Links to BS88: Part 5 J Type Current Rated Voltage Fixing Centres Interrupting Box Rating (ac) (mm) Rating Quantity 32MJ MJ MJ MJ Vdc 10 pcs 80MJ MJ MJ MJ MJ MJ MJ Vac 10 pcs 20MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ MJ PJ PJ Vac 10 pcs 355PJ PJ Vac 10 pcs For more information visit our website at 14
18 J Type Fuse Links for Low Voltage Feeder Piller Protection Fuse Links to BS88: Part 5 Current Rated Voltage Fixing Centres Interrupting Box Rating (ac) (mm) Rating Quantity 450RJ RJ Vac 10 pcs 800SJ Vac 10 pcs 560SJ SJ Vac 10 pcs 15 For more information visit our website at
19 Joint Service & NATO Fuse Links DEF Standard (NATO Reference System) Current Body Size Rated Voltage Fixing Centres Interrupting Box Rating (ac) (mm) Rating Quantity Vac 10 pcs Vac 25 pcs Vac 25 pcs Vac 25 pcs Vac 25 pcs Vac 25 pcs Vac 25 pcs For more information visit our website at 16
20 Low Voltage Fuse Links to BS88 & IEC269 Dimensional Data - Offset Bolted Tag A B C D E F G H J SMD F G H J I A B C D E F G H J STD I A B C D E F G H J NITD NITD32M A B C D E F G H J AAO AAO32M BAO BAO63M A B C D E F G H J CEO CEO100M125 & 160 CEO100M200 A B C D E F G H J A B C D E F G H J OSD OSD100M DEO DEO200M A B C D E F G H J For more information visit our website at
21 Low Voltage Fuse Links to BS88 & IEC269 Dimensional Data - Centre Bolted Tag A B C D E F G H K AC AD BC BC63M BD CD CD100M125 & CD100M CD100M DD DD200M ED ED315 ED315M400 ED400M EFS* * Except 315A A B C D E F G H J EFS315 EF355 & 400 EF400M500 FF FG GF GG710 & GG1000 & A B C D E F G H J GH710 & 800 GH1000 & For more information visit our website at 18
22 Low Voltage Fuse Links to BS88 & IEC269 Dimensional Data - 660V Offset Bladed Tag A B D E F N N H J SSD NSD & NSD20M 13.8 NSD20M36 & NSD32M ESD - 32A 13.8 ESD40-63A ESD63M 21.0 A B C D E F G H J H K L M Dimensional Data - 660V Centre Bolted Tag A B C D E F G H J K A K A K A K A A B C D E F G H J L M N P N A B C D E F G H J P P R R For more information visit our website at
23 Low Voltage Fuse Links to BS88 & IEC269 Dimensional Data - 660V Special Tag Range A B C D E F G H J M M N A B C D E F G H J N A B C D E F G H J P R A B C D E F G H J N P R S Dimensional Data - Special 500V DC Range A B C D F G H J HS KS A B C D E F G H KS KS For more information visit our website at 20
24 Low Voltage Fuse Links to BS1361, BS88 & IEC269 Dimensional Data - House Service & Feeder Piller Fuse Links Dimensions for KR85 Dimensions for LR85 Dimensions for MJ25-6 Dimensions for MJ30-7&-8 up to 200A Dimensions for MJ31-7 up to 200A Dimensions for PJ30-7 & MJ30-7 (250 & 315A) Dimensions for PJ31-7 & MJ31-7 (250 & 315A) Dimensions for RJ31-7 Dimensions for SJ31-6 Dimensions for SJ28 21 For more information visit our website at
25 Low Voltage Fuse Links to Defence Standard Dimensional Data for Joint Service Fuse Links Cylindrical (Cyl) Part No Current Body Tag Type A B C D E Rating Size Offset Bolted Tag (O.B.T.) Cyl Cyl Offset Bolted Tag Cyl Offset Bolted Tag Cyl Offset Bolted Tag For more information visit our website at 22
26 British Standard Low Voltage Industrial Fuse Links APPLICATION INFORMATION The Bussmann standard range of high breaking capacity fuse links for low voltage industrial and general purpose applications meet the requirements of BS88 and IEC By using advanced fuse technology the current ratngs up to 400A have compact dimensions but still within the standardised dimensional and performance requirements. These designs have been optimised for 415/240V systems. The standard range of fuse links are available from A in the following tag forms: OFFSET BLADED - OFFSET BOLTED - CENTRE BOLTED. Supplementary ranges cover applications up to 690V a.c. and 500V d.c. including those with non-standard tag fixings. Bussmann fuse links are manufactured under Quality Systems independently assessed to ISO 9001 and appropriate ratings carry the ASTA 20 endorsement. APPLICATION DATA One of the long standing advantages of fuse protection is that fuse selection is relatively simple and effective. The following notes cover the majority of applications. For further information contact Bussmann technical services on Reference should also be made to the appropriate Wiring Installation rules, in the UK the 16th Edition of the IEE Wiring Regualtions for Electrical Installations which aligns with IEC CIRCUIT LOADING The current rating of the fuse link should not be less than the full load current of the circuit. The circuit should be so designed that small overloads of long duration will not be of frequent occurence. CABLE RATINGS There is an increasing move away from 70 o C P.V.C. insulation to materials which are more environmentally friendly, for example 90 o C XLPE. The ratings of fusegear, switches, accessories etc. are generally based upon the equipment being connected to conductors intended to be operated at a temperature not exceeding 70 o C in normal service. In view of the above it is recommended that the practice of designs based upon conductor temperatures of 70 o C be regarded as the norm. In accordance with clause of the Wiring Regulations the equipment manufacturer should be consulted to ascertain the reduction of nominal current rating of the equipment if conductor temperatures exceeding 70 o C are used. In addition an overriding factor is often voltage drop consideration. CABLE PROTECTION Bussmann fuse links with gg characteristics protect associated cables against both overload and short circuit current, provided that the current rating of the fuse link I N is equal or less than the current carrying capacity of the cable I z. In motor circuits, the motor starter will provide the overload protection and the fuse links will provide the short circuit protection. The maximum size of fuse link that can be used depends upon the type of cable used and is determined in accordance with the Wiring Regulations using the appropriate K factor. The following table gives maximum sizes of fuse links that are recommended for two popular cables with copper conductors, 70 o C P.V.C. (K=115) and 90 o C thermosetting (K=143). Cable Size mm 2 K = 115 A Max. Fuse Rating K = 143 A , * 2,5 32* 32* 4 50* 50* 6 63* 63* * 125* * 160* * 250* * 355* * Zs OHMS IMPEDANCE VALUES The rules for protection against indirect contact are given in Chapter 413 of the Wiring Regulations. For a TN System a disconnecting time not exceeding 5s is permitted for a distribution circuit. The maximum values of earth fault loop impedance (Zs) corresponding to a disconnecting tme of 5s for nominal voltage to earth (Uo) of 240V for Bussmann gg fuse links. Rating (A) Zs Ohms Rating (A) Zs Ohms Rating (A) Zs Ohms Rating (A) Zs Ohms Ω Ω AMBIENT TEMPERATURE A de-rating in terms of current of 0.5% per o C above an ambient of 35 o C is recommended. BREAKING CAPACITY The standardised values of Breaking Capacity are 80kA for voltages of 415V a.c. and above, and 40kA for d.c. applications. DISCRIMINATION All fuse links will give a discrimination ratio of 2:1 and for most practical situations a ratio of 1.6:1 (two steps in the R10 series). Example: an upstream fuse rated at 160A will discriminate with a downstream fuse rated at 100A. CURRENT AND ENERGY LIMITATION The Bussmann range of fuse links have pre-arcing I 2 t values towards the bottom limits of the standards. This ensures excellent current and energy limitation. They also have lower power losses at rated current. This assists in the appropriate interchangeability with other makes of fuse links. TRANSFORMERS When fuse links are used on the primary side of transformers the normal current rating of the fuse links should be at least twice the nominal transformer primary current. FLUORESCENT LIGHTING The normal current rating of the fuse link should be at least twice the normal full load current of the maximum number of lights to be switched simultaneously. CAPACITOR CIRCUITS In capacitor circuits, for example power factor correction, the fuse link should be chosen with a current rating greater than 1.5 times the rated capacitor current. This takes account of the high transient inrush current, circuit harmonics and capacitor tolerances. MOTOR CIRCUITS In motor circuits the fuse link has to withstand the starting current of the motor and often requires a higher rating than the full load current of the motor. Co-ordination recommendations are made by the manufacturers of motor starters in accordance with IEC To give the desirable type 2 co-ordination with fuse links, tests are performed with the latest gg or gm fuse links, to BS88 or IEC60269 which have pre-arcing I 2 t values toward the bottom specified limits. This means that Bussmann fuse links are suitable to give type 2 co-ordination. Extended dual ratings of motor circuit protection fuse links with gm characterstics are available in most popular sizes of fuse links to extend the use of associated equipment with appropriate economies. In the majority of applications, gg fuse links are used. It is not essential for gm fuse links to be used for motor circuit protection, they simply extend the utilisation of standard equipment. The attached table shows the recommended fuse links at 415V. In most applications the run-up time is less than five seconds and duty is infrequent - no more than twice per house. The next larger rating should be used for more arduous conditions. Motor Rating DirectOn-line Standard (gg) Motor Circuit (gm) Asst Start Standard (gg) kw A A A A M M M M M M M M M M M M M M M M M *Extended motor circuit dual ratings can be used 23 For more information visit our website at
27 Low Voltage Fuse Links to BS88 & IEC269 Technical Data Time Current Curves for SMD Fuse Links I 2 t (Amps 2 Seconds) Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss SMD SMD SMD SMD SMD SMD SMD SMD SMD Time Current Curves for AAO, BAO, BC and BD Fuse Links I 2 t (Amps 2 Seconds) Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss AAO AAO AAO AAO AAO AAO AAO AAO BAO BC BD BAO BC BD BAO BC BD Time Current Curves for AC, AD, CD, CEO and OSD Fuse Links I 2 t (Amps 2 Seconds) Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss AC AD AC AD AC AD AC AD AC AD AC AD AC AD CEO AC AD CEO CEO CEO CEO CD OSD CEO CD OSD For more information visit our website at 24
28 Low Voltage Fuse Links to BS88 & IEC269 Technical Data Time Current Curves for NSD, NITD and ESD Fuse Links I 2 t (Amps 2 Seconds) Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss NSD NITD ESD NSD NITD ESD NSD NITD ESD NSD NITD ESD NSD NITD ESD NSD NITD ESD NSD NITD ESD NSD NITD ESD ESD ESD ESD Time Current Curves for SSD and STD Fuse Links I 2 t (Amps 2 Seconds) Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss SSD STD SSD STD SSD STD SSD STD SSD STD SSD STD SSD STD SSD STD Time Current Curves for NITD Motor Rated Fuse Links I 2 t (Amps 2 Seconds) Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss NITD 20M NITD 20M NITD 32M NITD 32M NITD 32M For more information visit our website at
29 Low Voltage Fuse Links to BS88 & IEC269 Technical Data Time Current Curves for NSD, AAO and BAO Motor Fuse Links I 2 t (Amps 2 Seconds) Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss NSD 20M NSD 20M NSD 20M NSD 32M NSD 32M NSD 32M NSD 32M AAO 32M AAO 32M AAO 32M BAO 63M BAO 63M Time Current Curves for DD, DEO, ED, EFS, EF, FF, FG, GF, GG and GH Fuse Links I 2 t (Amps 2 Seconds) x 10 3 Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss DD DEO EFS DD DEO EFS DD DEO EFS ED - EFS ED - EFS ED EF ED EF FF FG FF FG FF FG FF FG GF GG GH GF GG GH GG GH GG GH Time Current Curves for DD, DEO, ED and EF Motor Fuse Links I 2 t (Amps 2 Seconds) x 10 3 Amp Pre- Total at Ratings Arcing 415V Nom. Watts Loss DD DEO 200M DD DEO 200M ED - 315M ED EF 400M For more information visit our website at 26
30 Low Voltage Fuse Links to BS88 & IEC269 Comparison Chart For more information visit our website at 27 Competitor 100MFB 100MF 100MFC 200MFB 200MFC 200MFD 20MFB 20MFC 20MFD 32MFB 32MFC 32MFD 63MFB 63MFC 63MFD 84TF( A) 84TK( ) 85TM( ) 86TT( ) 86TZ ES(40-63A) GTIA(2-32A) JHU(20-250) JPU(80-315) JPU(32-63) JPU( ) JSU(20-315) JSU( ) JSU( ) JSU( ) JSU(800) JSU(80-315) LBI100BC/BCBK LBI100FC/BCBK LBI100FC/FCBK LB1200BC/BCBK LBI200FC/BCBK LBI200FC/FCBK LBI20BC/BCBK LBI20FC/BCBK LBI20FC/FCBK LBI32BC/BCBK LBI32FC/BCBK LBI32FC/FCBK LBI63BC/BCBK LBI63FC/BCBK LBI63FC/FCBK LCF32BC/BCBK LCF32BC/BCWH LCF32FC/BBCBK LCF32FC/BBCWH Bussmann 32NNSFBS 32NNSFBS/W 32NNSF 32NNSF/W 63ENBSBS 63ENBSBS/W ENSFBS 63ENSFBS/W 32ENSF 63ENSF/W STD STD SMD KR85 ESD LR85 NITD NSD OSD CM100F CM100F+63/100BS CM100F+63/100BS 200DF 200DBS 200DFBS CM32FC CM32FC+32BSC CM32FC+32BSC CM32F CM32F+32BS CM32F+32BS CM63F CM63F+63/100BS CM63F+63/100BS NITD AAO AAO BAO - 32NNSF 32NNSF/W 32NNSBSBS 32NNBSBS/W - 63ENSF 63ENSF/W 63ENBSBS Bussmann CM100F CM100F CM100F+63/100BS 200DF 200DBS 200DFBS CM32FC CM32FC+32BSC CM32FC+32BSC CM32F CM32F+32BS CM32F+32BS CM63F CM63F+63/100BS CM63F+63/100BS M13 N15 P20 R20 S20 ESD AAO MJ29-6 MJ30-7 MJ30-8 PJ30-7 MJ31-7 PJ31-7 RJ31-7 SJ31-6 SJ28 MJ31-7 CM100F+63/100BS CM100F+63/100BS CM100F 200DBS 200DFBS 200DF CM32+32BSC CM32FC+32BSC CM32FC CM32F+32BS CM32F+32BS CM32F CM63F+63/100BS CM63F+63/100BS CM63F 32NNBSBS 32NNBSBS/W Competitor LCF32FC/BCBK LCF32FC/BCWH LCF32FC/FCBK LCF32FC/FCWH LCF63BC/BCBK LCF63BC/BCWH LCF63FC/BBCBK LCF63FC/BBCWH LCF63FC/BCBK LCF63FC/BCWH LCF63FC/FCBK LCF63FC/FCWH LS(2-32A) LST(2-32A) MD(2-32A) ME(5-100) MES(10-63A) MF(30-100) NIT(2-32A) NS(2-32A) OS(80-100) RS100H RS100P RS100PH RS200H RS200P RS200PH RS20H RS20P RS20PH RS32H RS32P RS32PH RS63H RS63P RS63PH (2-20A)SA2 (2-32A)SB2 (2-32A)SB3 (40-63A)SB4 SC32BH SC32H-D SC32H-D WHITE SC32P SC32P WHITE SC63BH SC63H-D SC63H-D WHITE SC63P Competitor (80-100A)SD5 ( A)SD6 (2-32A)SE3 (40-63A)SE4 (2-32A)SF3 (40-63A)SF4 (80-100A)SF5 ( A)SF6 ( A)SF7 ( A)SF8 ( A)SG7 ( A)SH10 ( A)SH8 ( A)SH9 (2-32A)SN2 (80-100A)SO (16-63A)SP SS(AMP) SW6 SW7 SX8 SX9 SY10 SY9 TB(2-32A) TB(40-63A) TBC(2-32A) TBC(40-63A) TC(80-100A) TCP(80-100) TF( A) TFP( A) TIA(2-32A) TIS(35-63A) TKF( A) TKM( A) TLM( A) TLT( A) TM( A) TMF( A) TMT( A) TT( A) TTM( A) V32FB V32FBW V32FF V32FFW V63FB V63FBW V63FF V63FFW Bussmann CEO DEO AC BC AD BD CD DD ED ED EFS GF EF FF NSD OSD ESD SSD M13 N15 P20 R20 GG FG AC BC AD BD CD CEO DD DEO AAO BAO ED EFS GF GG EF ED P12 FG FF 32NNSFBS 32NNSFBS/W 32NNSF 32NNSF/W 63ENSFBS 63ENSFBS/W 63ENSF 63ENSF/W
31 CAM ASTER HRC Fuse Holders Introduction A patented range of fully shrouded HRC Fuse Holders designed to accomodate offset bolted tag HRC fuse links to BS88: Parts 1 & 2; IEC & 2. All Camasters are rated at 690Vac. The compact dimensioned 32A Fuse Holder, type CM32FC and CM20F accept the A1 size fuse link NITD 2 to 32 Amps. The standard 32A Fuse Holder, type CM32F and CM20F accept the A2 size fuse link AAO 2 to 32 Amp. The 63A unit, type CM63F accepts the A3 size fuse link BAO 40 to 63 Amp and the 100 Amp unit,type CM100F accepts fuse link type OSD 80 to 100 Amps, which has compact A3 fixing centres. The Fuse Holders are supplied as front connecting as standard but can be readily converted to front/back stud or double back stud connection types at the point of installation, using the appropriate size back stud accessories. CAMASTER Fuse Holders are offered with the following features: Advanced patented design incorporating a high level of innovation with enhanced performance characteristics. Camaster Fuse Holders fully comply with the requirements of BS88 section 2.2 (IEC , section 2) and the 16th edition of the IEE Wiring Regulations (BS7671). The fuse carriers are fitted with a cam action for ease of removal from the fuse base. The design ensures high contact pressure between the fuse carrier contacts and the base contacts, with a corresponding enhanced electrical performance level. Camaster Fuse Holders have a unique channel and guide arrangement which prevents any tilting of the fuse carrier when it is being inserted or removed, eliminating any likelihood of inadvertent contact with live metal. Fixing screws to the fuse carrier are held in captive hinges, providing ease of fixing and preventing loss during installation. The hinges also act as pressure plates thereby reducing the contact resistance between the fuse link tags and the carrier contact. Cable terminations fully meet the requirements of sub-clause terminals of IEC60947: Part 1 Low Voltage Switchgear and Controlgear. Camaster Fuse Holders, as standard, provide both bolted panel and DIN rail mounting features. When DIN rail mounted all ratings of fuse holder give equal height and depth above and below the DIN rail. Non removable full shrouding of live parts within the fuse base provided by the use on hinged shields which cannot be omitted during installation and are designed so that insertion of the fuse carrier can only be made with them correctly positioned. Neon clip-in indicator accessories are available, the neon being lit when the fuse link has operated. (Minimum system operation 90V). The fuse carrier has a marking label for ease of circuit identification. Ganging can be readily achieved by the use of standard accessories, providing improved safety related to isolation and protection of 2 and 3 pole electrical circuits. For more information visit our website at 28
32 CAM ASTER HRC Fuse Holders Ratings, Catalogue Numbers & Dimensions Standard front connected unit. Suitable for either bolted panel or DIN rail mounting. Front/Back stud and double back stud connected units. These allow easy customer conversion (illustrated below right) to either Front/Back or double back configuration, by use of Back stud assembly packs, using only a screwdriver. Rating (A) Max Cable mm 2 Rec. Fuse Link A B C D E F G H J K 20 CM20F 16 NITD M6 32 CM32FC 16 NITD M6 32 CM32F 16 AAO M6 63 CM63F 70 BAO M8 100 CM100F 70 OSD M8 Notes. 1. Type CM32FC is also available rated at 20A, catalogue number CM20F 2. For colours other than Black (standard) add the appropriate letter code: W = White; G = Green; GY = Grey 3. Care must be taken when fitting solid single or stranded cables of small cross-sectional area to ensure correct clamping. Multi-stranded cables must be terminated with bootlace ferrules to ensure correct clamping. Conversion Sequence A Accessory Rating (A) Part no. Carton Qty BSC 10 Back stud 32 32BS 10 63/100 63/100BS 5 B Ganging Links GLP 1 Set Neon Indicator V ac NI 3 1. Remove carrier using the Cam Lever. Insert screwdriver at position A gently lever and push ferrule upwards to remove. 2. Insert Back Stud accessory. 3. Raise contact shield by inserting screwdriver at position B. Tighten terminal screw. 4. Repeat steps 1, 2 & 3 at opposite end to give Double Back Stud connection. Lockable 32LSCC 3 Safety Carriers 32LSC 3 63/100LS 3 Security Clip CMSC 20 Neutral 32 32CMLC Links 32 32CML 1 63 /100 63/100CML 29 For more information visit our website at
33 SAFE LOC HRC Fuse Holders Introduction The patented Safeloc fuse holders provide a simple, safe range, designed to accommodate the compact range of offset blade tag fuse links to BS88 part 6 and IEC section IV. The combination offers significant savings in volume and cost as well as a reduction in fitting time and power loss. They provide a safe and easy method of protecting a wide range of electrical equipment such as lighting, heating, motor and control equipment circuits. The NNS fuse holder accomodates the NSD 2-32A range of compact HRC fuse links whilst the slightly larger ENS fuse holder accomodates the ESD 2-63A range of compact HRC fuse links. Both holders are available in front connection or back stud arrangements or combinations of these. SAFELOC Fuse Holders are offered with the following features: Compact fuse link and fuse holder dimensions. Fuse holders employ a unique slide/snap carrier action for positive and secure insertion and removal of the fuse link. This provides positive, stress free fitting of fuse links and locks the fuse link in position ensuring safe insertion and withdrawal from the base. The direct contact between fuse link blades and the plated base contacts provides low watts loss with increased reliability. The compact range of fuse links (i.e. NSD & ESD) fitted into the Safeloc fuse holders, have an excellent ability to protect induction motor circuits. Complete internal personal protection against direct contact electric shock is obtained by fully insulated and shrouded fuse holder base contacts. The fuse base utilises glass filled, high impact resistant, thermoplastic polyester and incorporates a 35mm DIN rail mounting facility as well as a single screw fixing. Fuse Link Ratings Motor Fuse Link Ratings Safeloc Type NNS ENS Safeloc Type NNS ENS Fuse Link Type NSD ESD Fuse Link Type NSD ESD M25 63M M32 63M M Vac M NSD 415 Vac 32M ESD 415 Vac 32M M Vac Notes on Motor Circuits All of the compact range of fuse links have an excellent ability to protect induction motor circuits. The unique design of the Safeloc Fuse Holders has enabled the design of dual rated fuse links which offer protection for motor ratings up to 30kW. Type gm fuse links for the protection of motor circuits have dual rated characteristics. For example, an ESD63M100 has a continuous current carrying capability of 63A, coupled with the time current characteristic and the capabilities of a 100A fuse link. For more information visit our website at 30
34 SAFE LOC HRC Fuse Holders Ratings, Catalogue Numbers & Dimensions Available Variants Catalogue Reference NNS NNS 32ENS Front Connected/Front Connected 32NNSF 63ENSF Back Stud/Back/Stud 32NNSBS 63ENSBS Front Connected/Back Stud 32NNSFBS 63ENSFBS Neutral Links 32NNL 63ENL Suitable for either Bolted Panel or DIN rail mounting. 63ENS BACK STUD OPTION For colours other than Black (standard), add the appropriate letter code: W = White; G = Green; GY = Grey, at the end of the catalogue reference. Security seal (ref ) available for 32A Safeloc. Rating (A) Max Cable mm 2 Rec. Fuse Link A B C D E F G H J K 32 NNS 16 NSD M6 63 ENS 35 ESD M8 Care must be taken when fitting solid single or stranded cables of small cross-sectional area to ensure correct clamping. Multi-stranded cables must be terminated with bootlace ferrules to ensure correct clamping. 31 For more information visit our website at
35 Part Numbers Code Page No. Code Page No. Code Page No. Code Page No. Code Page No KR L LO LR MJ MJ MJ HO HSO KO KR KSO M M M MJ MJ MJ MO N N NO KR M M M MJ MJ MJ MO N N NO HO HSO K KO KSO M M M MJ MJ MJ MO N N NO HO HSO KO KO KR KSO MJ MJ MJ MJ N N N N PJ HO HSO KR KSO MJ HO KO KO KR LR MJ MJ N N N N PJ BS 30 32BSC 30 32CML 30 32CMLC 30 32HO HSO KO KO KSO LSC 30 32LSCC 30 32MJ MJ NNL 31 32NNSBS 31 32NNSF 31 32NNSFBS P P P PJ PO P P P PJ PO KO KO KO KR KSO KSO KSO LR MJ MJ MJ R R R R RJ KR HO KO KO R R R R RJ K KO KO KR KSO KSO KSO LR MJ MJ R R R SJ KR KR LR ENL 31 63/100BS 30 63/100CML 30 63/100LS 30 63ENSBS 13 63ENSF 31 63ENSFBS R R R SJ KO KO KO KSO KSO KSO MJ MJ MJ HO KO KO KR LR S S SJ KR L LO LR MJ MJ MJ AAO2 1 AAO20 1 AAO32 1 AAO32M40 1 AAO32M50 1 AAO32M63 1 AAO4 1 AAO6 1 AC10 3 AC16 3 AC2 3 AC20 3 AC25 3 AC32 3 AC4 3 AC6 3 AD10 3 AD16 3 AD2 3 AD20 3 AD25 3 AD32 3 AD4 3 AD6 3 BAO35 2 BAO40 2 BAO50 2 BAO63 2 BAO63M100 2 BAO63M80 2 BC40 3 BC50 3 BC63 3 BC63M100 3 BC63M80 3 BD40 3 BD50 3 BD63 3 CD100 3 CD100M125 3 CD100M160 3 CD100M200 3 CD80 3 CEO100 2 CEO100M125 2 CEO100M160 2 CEO100M200 2 CEO32 2 CEO40 2 CEO50 2 CEO63 2 CEO80 2 CM20F 30 CM32F 30 CM32FC 30 CM63F 30 CM100F 30 CMSC 30 DD125 3 DD160 3 DD200 3 DD200M250 3 DD200M315 3 DEO125 2 DEO160 2 DEO200 2 DEO200M250 2 DEO200M315 2 ED250 4 ED315 4 ED315M400 4 ED400 4 ED EF355 4 EF400 4 EF400M500 4 EFS125 4 EFS160 4 EFS200 4 EFS250 4 EFS315 4 ESD10 6 ESD16 6 ESD2 6 ESD20 6 ESD25 6 ESD32 6 ESD4 6 ESD40 6 ESD50 6 ESD6 6 ESD63 6 ESD63M100 6 ESD63M80 6 FF450 4 FF500 4 FF560 4 FF630 4 FG450 4 FG500 4 FG560 4 FG630 4 GF800 5 GG GG GG710 5 GG710 5 GG800 5 GH GH GH710 5 GH800 5 GLP 30 NI 30 NITD10 1 NITD16 1 NITD2 1 NITD20 1 NITD20M25 1 NITD20M32 1 NITD25 1 NITD32 1 NITD32M40 1 NITD32M50 1 NITD32M63 1 NITD4 1 NITD6 1 NSD10 6 NSD2 6 NSD20 6 NSD20M25 6 NSD20M32 6 NSD20M36 6 NSD25 6 NSD32 6 NSD32M36 6 NSD32M40 6 NSD32M50 6 NSD32M63 6 NSD4 6 NSD6 6 OSD100 2 OSD100M125 2 OSD100M160 2 OSD80 2 SMD10 1 SMD16 1 SMD2 1 SMD20 1 SMD25 1 SMD32 1 SMD4 1 SMD6 1 SMD8 1 SSD10 6 SSD16 6 SSD2 6 SSD20 6 SSD25 6 SSD32 6 SSD4 6 SSD6 6 STD10 1 STD16 1 STD2 1 STD20 1 STD25 1 STD25 1 STD32 1 STD4 1 STD6 1 For more information visit our website at 32
36 Notes 33 For more information visit our website at
37 Notes For more information visit our website at 34
38 Notes 35 For more information visit our website at
39 BUSSMANN OFFICES AROUND THE WORLD EUROPEAN HEADQUARTERS Bussmann Division Cooper (UK) Limited Burton on the Wolds Leicestershire LE12 5TH, UK Telephone: +44 (0) Facsimile: +44 (0) HEADQUARTERS Cooper Bussmann, Inc P.O. Box St. Louis, Missouri , USA Telephone: Facsimile: Bussmann in Denmark Bussmann International Inc., USA Subsiduary of Cooper Industries Inc., Literbuen 5 DK-2740 Skovlunde Copenhagen Denmark Telephone: Facsimile: Bussmann in Mexico Arrow-Hart S.A. de C.V Poniente 148, No Mexico, D.F. Mexico Telephone: Facsimile: Bussmann in Australia Bussmann Block X 391 Park Road Regents Park NSW 2143 Australia Telephone: Facsimile: Bussmann in Brasil Bussmann do Brasil Ltda Rodovia Santos Dumont, KM Cruz das Almas Cabra Postal 95 - Itu Sao Paulo Brasil Telephone: Facsimile: Bussmann in India Bussmann Cooper (U.K.) Limited SF-5 White House St. Marks Road Bangalore India Telephone: Facsimile: Bussmann Circuit Components West Wilson Avenue Chicago, IL , USA Telephone: Facsimile: Bussmann Asia Pacific 1 Jalan Kilang Timor # Pacific Tech Centre Singapore Telephone: Facsimile: This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right to change design or construction of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
40 NH FUSE SYSTEM D & D0 LOW VOLATAGE FUSE SYSTEM CIRCUIT PROTECTION SOLUTIONS Bussmann is one of the world s leading suppliers of fuses and fusible protection systems. Provider of the world s first truly NH FUSE SYSTEM D & D0 LOW VOLTAGE FUSE SYSTEM global product line, each product is backed IEC CYLINDRICAL FUSE SYSTEM OPTIMA FUSE SYSTEM by an efficient world-wide distribution network service and unrivalled technical support. Bussmann circuit protection solutions comply with major international standards: BS, IEC, DIN and UL. IEC CYLINDRICAL FUSE SYSTEM OPTIMA FUSE SYSTEM A comprehensive range of circuit HIGH SPEED FUSES HIGH VOLTAGE PRODUCTS protection solutions fused and non-fused. LVFL HIGH SPEED FUSES HIGH VOLTAGE PRODUCTS Cooper Bussmann Cooper (UK) Limited Burton-on-the-Wolds Leicestershire LE12 5TH UK Telephone: 44 (0) Facsimile : 44 (0) Your Representative Cooper Bussmann Printed January COOPER BUSSMANN
IEC and British Standard Fuses
IEC and British Standard Fuses Section Contents Page Application Data...7-8 CSA Type P and Type D fuses (CDS, CDN & PON)............................9 Tron HRC Form II Class C fuses (CGL Form II Class C)..........................
Packaging: MOQ: NIT, NET, TIA and TIS 20 per pack TCP and TFP 10 per pack Packaging 100% recyclable. Technical Data:
Packaging: MOQ: NIT, NET, TIA and TIS 20 per pack TCP and TFP 10 per pack Packaging 100% recyclable Catalogue Symbol: Class of Operation: Fuse Size: NIT (amp rating) NET (amp rating) TIA (amp rating) TIS
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
GE Power Controls. MiniFORM Switchboards
GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Photovoltaic System Overcurrent Protection
Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and
BETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or
IEC 60269 gg & am STANDARD LOW VOLTAGE FUSE
IEC 60269 gg & am STANDARD LOW VOLTAGE FUSE. INTRODUCTION 2. INTRODUCTION TO THE IEC 60269 STANDARD 3. COMPARISON OF THE TIME CURRENT CURVES OF DIFFERENT FUSE TYPES 3.. Comparison of IEC and UL fuses 3.2.
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Slimline Plus. Catalogue No. R6
Slimline Plus Catalogue No. R6 slimline plus Stylish Robust Ease of installation Affordable For over 55 years, MK Electric has been a household name throughout the Asia Pacific region, trusted and respected,
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Fuse Selection Method Module 2. Date of the presentation
Fuse Selection Method Module 2 Date of the presentation Fuse Selection When selecting LV fuses certain important information must be known. 1.System Voltage This is the voltage of the system or distribution
British BS 88 Fuses. Introduction
British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
Distribution Boards & Consumer Units
Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
Rotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors
ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants Installation instructions Contents Key points of installation Before installation Installation Installation check
FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches
FUSERBLOC Fuse combination switches appli_8_a fuser_548_a cat fuser_59_a cat fuser_52_a cat 2 to 25 A Manual operation Function FUSERBLOC are manually operated multipolar fuse combination switches. They
SELECTION OF FINAL CIRCUIT PROTECTION
SELECTION OF FINAL CIRCUIT PROTECTION By Phil Williams, Product Marketing Manager, Power Distribution Components, Eaton Executive summary The selection of devices for final circuit protection in electrical
How To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
Bussmann series Third rail fuse links application guide. Leadership in fusible circuit protection solutions
Bussmann series Third rail fuse links application guide Leadership in fusible circuit protection solutions Eaton s Bussmann business has over 100 years of experience in the design and manufacture of fuse
7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Masterseal TM. Compact. Ingress Protected IP66
Masterseal TM Compact Ingress Protected IP66 Features INGRESS PROTECTED IP66 The new and innovative Masterseal TM Compact range of switches and sockets from MK, has been specifically designed for use in
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
General Purpose Relays Accessories. Accessories Miniature Relay PT
Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch
2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions DS1/DSS Instructions for Installation
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
FAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole
Catalogue May 2015 EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1-pole 2 Overview 2-pole 3 Overview 3-pole 4 Overview 4-pole 5 Electronic Fuse Monitoring 6 Busbar
CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61
FUSES Catalogue CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61 INTRODUCTION The main function of current limiting fuses is to protect electrical apparatus, such as distribution transformers, motors
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01
SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
PSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) 1268 563720. www.mkelectric.com IP66. Improved catch.
Masterseal Plus TM technical hotline +44 (0) 268 63720 Improved catch Rear drill holes Available in grey, white and black Fixed gasket speds installation gasket Now has all the features and logic plus
IO-RM3 3-Stage Relay Module
Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Medium voltage products. Fuses
Medium voltage products Fuses Index Introduction... 3 Main definitions... 4 ABB HV Fuses with Temperature Control Unit... 5 General principles for fuse link selection... 6 CEF... 8 CEF-S... 16 CEF-VT...
V REG.-Nr. 115719, Z E135149 Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays
Accessories Miniature Relay PT Easy replacement of relays on a densely packed DIN rail No reduction of protection class or creepage/clearance with plastic retainer Plug-in indicator- and protection modules
picomax The Pluggable Connection System
picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
High Speed Fuses. High Speed Fuses
Section Contents Page General Applications........................ 9-95 North American fuses & accessories............9-113 DFJ - High speed Class J fuse...................97 Square Body fuses & accessories............
Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125
Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures
NEW RANGE OF CABINETS DRIVIATM Innovation at your service THE GLOBAL SPECIALIST in electrical and digital building infrastructures Drivia true innovation The new electrical panel for the residential and
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes
BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can
Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
IO-DIM6 6-Channel, Digital to Analogue Converters
Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication
Model Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
Plug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle