SPIRAL/HELICAL multirow detector computed tomography
|
|
|
- Emily Moody
- 9 years ago
- Views:
Transcription
1 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 19, NO. 9, SEPTEMBER Guest Editorial Multirow Detector and Cone-Beam Spiral/Helical CT SPIRAL/HELICAL multirow detector computed tomography (MDCT), also referred to as multislice spiral CT (MSCT), has attracted a major interest since its recent introduction [18], [33]. Compared with single-row-detector systems, MDCT scanners allow faster data collection and thinner slices that support more demanding clinical applications and present new research opportunities. This special issue consists of 12 original papers from this rapidly expanding field. Although MDCT generally refers to commercial CT scanners used by radiologists, the work in this issue is also applicable to emission CT as well as nonmedical applications of X-ray CT, including nondestructive testing and microtomography. In this editorial, we provide a summary of the special issue, an overview of the field, and suggestions for future work. I. CONTENT OF THE SPECIAL ISSUE The first eight papers represent recent work on X-ray CT image reconstruction in multirow detector or cone-beam geometry. The first two papers by Schaller et al.report an adaptive axial interpolation theory for a MDCT scanner with experimental verification [13], [29]. Adaptive axial interpolation provides increased flexibility for image reconstruction in clinical practice. By keeping slice thickness and image noise independent of pitch, the MDCT parameter selection is simplified. The paper by Proksa et al. introduces the -PI-method for spiral/helical cone-beam CT (CBCT) [27]. This method assumes a detector array shaped by a helix, permits variable pitch, and is amendable to both exact and approximate reconstruction. The paper by Hsieh addresses the degradation in image quality of spiral/helical MDCT when the gantry is tilted to produce oblique sections [17]. He formulated a model as an analytical basis and developed several compensation schemes. The paper by Bruder et al. describes two different approximate single-slice algorithms for CBCT: multirow Fourier reconstruction (MFR) and advanced single-slice rebinning (ASSR), in the framework of the generalized parallel projection using -filtering [3]. Their studies contain data valuable for the design of spiral/helical CT scanners with medium cone-beam angles. The paper by Kachelrieß et al. proposes MDCT algorithms for cardiac imaging [19]. Based on ECG signals, the two dedicated cardiac reconstruction algorithms improve image quality compared with the standard reconstruction algorithms. The paper by Kudo et al. [21] deals with the long-object problem; that is, to reconstruct a region of interest (ROI) of a long object from data collected along a helical path that extends only marginally above and below the ROI. Their quasi-exact reconstruction algorithms require no Publisher Item Identifier S (00) /00$ IEEE additional circular scans and are in the filtered backprojection format. The paper by Zhao and Wang contains a wavelet-based derivation and construction of the Feldkamp-type algorithms [46]. They found that a three-dimensional (3-D) ROI can be reconstructed without severe artifacts nor any significant bias. The subsequent papers are on detector evaluation and system characterization. The paper by Hsieh et al.presents the signal decay and afterglow characteristics of a solid-state detector, the resultant image artifacts, and a correction scheme [17]. The paper by Fuchs et al.compares Xenon and solid-state detectors under working conditions [12]. The paper by Ning et al. characterizes a flat-panel-detector-based CBCT angiography system [26]. The last paper by Wan et al. discusses extraction of the hepatic vasculature in rats from a micro-ct image volume [38]. II. OVERVIEW AND FUTURE OF THE FIELD With the rapid development of spiral/helical MDCT, spiral/helical CBCT should be the future of medical X-ray CT. The principal difference between MDCT and CBCT is that the former implies that the cone-angle is insignificant, whereas the latter takes the cone-angle into account so that more detector rows can be used. As in MDCT, the cone-angle is only a couple of degrees and can be ignored in image reconstruction. In the near future, the small cone-angle will likely be expanded to medium cone angles by adding more detector rows. Consequently, correction for the cone-beam effect should be included. Eventually, for large cone-angles, reconstruction algorithms must rigorously accomodate the cone-beam geometry. Furthermore, unlike other cone-beam CT systems, spiral/helical CBCT only collects longitudinally truncated projection data along a helical scanning locus. Over the past two decades, various CBCT algorithms have been developed. In the following, we share our observations on advantages/disadvantages of these algorithms. A. Exact Algorithms Traditional exact cone-beam reconstruction algorithms were designed according to the theory developed by Smith [31], Tuy [37], and Grangeat [14]. The sufficient condition for exact cone-beam reconstruction is that on every plane that intersects the object there exists at least one cone-beam source point [31]. When this condition is satisfied, the Grangeat formula relates the line integral of cone-beam data to the planar integrals in the 3-D radon space for exact image reconstruction. However, these exact algorithms assume that every cone-beam projection must completely contain an object to be reconstructed; hence, they cannot be used in spiral/helical CBCT, where projection data are longitudinally truncated.
2 818 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 19, NO. 9, SEPTEMBER 2000 With a recent generalization of the Grangeat formula [20], [35], exact image reconstruction is possible in spiral/helical CBCT with longitudinally truncated data [6], [20], [21], [25], [35], [36]. The fundamental concept is to synthesize a mosaic of truncated fan-beams in any plane intersecting an ROI, apply the generalized Grangeat formula to triangular sections defined by the fan-beams, and accumulate their contributions to recover the planar integrals needed for exact reconstruction. A key to understanding the completeness of such data is to recognize that the detection window delineated by two consecutive turns of the helical path on the scanning cylinder allows a seamless X-ray coverage of the ROI [34]. B. Approximate Algorithms Feldkamp et al. [8] heuristically adapted the fan-beam algorithm for approximate cone-beam reconstruction in the case of a circular locus. The Feldkamp algorithm was generalized for spiral/helical CBCT [39] [41], [45] to allow either full-scan or half-scan data from flexible 3-D loci, including a helix. In addition to these Feldkamp algorithms, other approximate algorithms were recently developed in the filtered-backprojection framework [3], [4], [15], [16], [19], [24], [27], [29], [30], [46]. Despite elegant results on exact cone-beam reconstruction, approximate cone-beam algorithms remain practically and theoretically valuable. In the ideal case that projection data are complete, consistent, noise-free, and manipulated in the continuous domain, the exact approach would be the method of choice. However, measurement noise, missing data, data interpolation, patient motion, digital processing, and dose utilization must be taken into account in practice, which have significant impacts on image quality. Relative to the exact spiral/helical CBCT algorithms, the approximate image reconstruction algorithms have the following advantages. First, the approximate algorithms may produce better spatial/contrast resolution. An important fact is that projection data are necessarily contaminated by noise, especially in low-dose CT screening and CT fluoroscopy. Because the approximate reconstruction requires only one-dimensional (1-D) data filtering, instead of two-dimensional (2-D) data filtering (differentiation is considered as equivalent to filtration) required in the exact reconstruction, the approximate reconstruction needs less regularization than does the exact reconstruction for a given image noise level. In other words, the spatial resolution is less compromised in the approximate reconstruction in this situation. It is possible to tolerate higher noise levels and produce a better spatial resolution, but the contrast resolution would be reduced. For example, exact cone-beam reconstruction with the direct Fourier method produces more noise and ringing compared with the Feldkamp method [1]. The problems may be inherent to all exact cone-beam reconstruction algorithms that filter data two-dimensionally. Furthermore, data interpolation is less involved in the approximate algorithms; hence, less image blurring will occur from this type of data processing, relative to "exactly" reconstructed images. Second, the approximate algorithms produce better temporal resolution. In the exact cone-beam reconstruction algorithms, multiple source points are needed to define a partition of each plane through an ROI. Therefore, the angular range of projection data may span several helical turns. In contrast to the extensive data range of the exact algorithms, the approximate algorithms work only with either full-scan or half-scan data. The less the angular range involved, the better the temporal resolution, which is critical for cardiac imaging, lung imaging, and CT-guided medical interventions. Third, the approximate algorithms are computationally more efficient. The approximate reconstruction involves less raw data; hence, it requires less computing resources. The computational structure of the approximate reconstruction is relatively straightforward, highly parallel, and hardware supportable. The approximate algorithms are particularly faster for reconstruction of a limited number of slices or small ROIs. The power of the approximate algorithms can be further appreciated from the relationship between the exact reconstruction and the Feldkamp reconstruction. On the one hand, the exact reconstruction naturally degrades to the Feldkamp reconstruction when the scanning locus is circular [5], [31]. On the other hand, there is a fundamental link from the Feldkamp reconstruction to the exact reconstruction [44]. Briefly speaking, according to the steps of the Feldkamp reconstruction, the approximate reconstruction may be achieved in a rotated reconstruction system. Being consistent to the well-known property of the Feldkamp algorithm that the vertical integral of a reconstructed volume is exact, it can be proved that the integral of a reconstructed image along the rotated -axis is also exact. In other words, exact 2-D parallel projections can be synthesized along various directions. If the sufficient condition for exact cone-beam reconstruction is satisfied, a sufficient amount of exact 2-D parallel projections can be synthesized using the Feldkamp approach; hence, the exact image reconstruction can be performed. C. Iterative Algorithms In addition to the exact and approximate spiral/helical CBCT algorithms, which are based on closed-form inversion of projection data, iterative algorithms may be important in medical X-ray CT because of their capability of handling photon fluctuation and the ever-improving computing technology. A major common weakness of the noniterative algorithms, either exact or approximate, is that projection data are implicitly assumed to be noise-free. However, noise is an inherent aspect of projection data, especially for low-dose scans. Because CT can be viewed as a parameter estimation problem in the case of low-count projection data, the statistical approach should have a central role in image reconstruction [11]. Iterative statistical reconstruction methods have been successful in emission CT, primarily in PET and SPECT [25]. Since the publication of the first iterative X-ray CT algorithm for the maximum likelihood (ML) reconstruction [22], several new iterative X-ray CT algorithms [23], [9], [10] were proposed to accelerate the original ML algorithm. The recent algorithm based on paraboloid surrogates [7] is guaranteed to be monotonic with the computing time comparable to that of penalized weighted least squares (PWLS) methods [11]. The expectation maximization (EM) algorithm for emission CT was adapted for X-ray CT according to the I-divergence minimization interpretation [32], [42]. It was demonstrated that the EM emission CT algorithm, also referred to as the iterative deblurring algorithm, is promising for image noise suppression and metal artifact reduction in X-ray CT. Furthermore, the EM
3 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 19, NO. 9, SEPTEMBER emission CT algorithm can be greatly accelerated using the ordered-subset or row-action scheme [2], and may be adapted for X-ray CT, especially in the case of CT fluoroscopy [43]. Iterative algorithms have potential with further development to surpass the exact or approximate algorithms in important applications, including image denoising, metal artifact reduction, local region reconstruction, and CT fluoroscopy. Iterative algorithms can be either approximate or exact (in the sense of the limiting case), depending on the completeness of the scanning and detection geometry. Parallel/array processing techniques are particularly valuable for implementation of iterative algorithms. III. CONCLUDING REMARKS All three types of spiral/helical CBCT algorithms have unique advantages. The exact algorithms can produce accurate images when data are complete and noiseless. The approximate algorithms may outperform the exact algorithms when data are noisy or involved with moving structures. The iterative algorithms should be preferred when data are very noisy or incomplete. Approximate and iterative algorithms may produce artifacts when data are sparse. In addition to our qualitative comments on these spiral/helical CBCT algorithms, quantitative comparison should be performed for specific tasks. Given a generic CT algorithm, image quality indexes are not uniquely specified. For example, spatial resolution and contrast resolution can be altered by either preprocessing data or postprocessing images. The optimal protocol for any application should be established according to clinical requirements, based on comparative studies, and using relationships among image quality indexes and imaging parameters. IV. ACKNOWLEDGMENT The authors express their appreciation to the anonymous reviewers, who were instrumental in the rigorous peer-review process for each of the manuscripts submitted to this issue, K. Escher for her editorial assistance, and Dr. M. Vannier, Editor-in-Chief, for his support and advice. GE WANG, Guest Editor University of Iowa Departments of Radiology and Biomedical Engineering Iowa City, IA USA ( [email protected]) CARL R. CRAWFORD, Guest Editor Analogic Corporation Peabody, MA USA ( [email protected]) WILLI A. KALENDER, Guest Editor Friedrich-Alexander-University Erlangen-Nürnberg Institute of Medical Physics Erlangen, Germany ( [email protected]) REFERENCES [1] C. Axelsson and P. E. Danielsson, Three-dimensional reconstruction from cone-beam data in o(n log n) time, Phys. Med. Biol., vol. 39, pp , [2] J. Browne and A. R. De Pierro, A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography, IEEE Trans. Med. Imag., vol. 15, pp , [3] H. Bruder, M. Kachelrieß, S. Schaller, K. Stierstorfer, and T. Flohr, Single-slice reconstruction in spiral cone-beam computed tomography, IEEE Trans. Med. Imag., vol. 19, pp , [4] P. E. Danielsson, P. Edholm, J. Eriksson, M. M. Seger, and H. Turbell, The original PI-method for helical cone-beam CT, in Proc Int. Mtg. on Fully 3D Image Reconstruction in Radiology and Nuclear Medicine, pp [5] M. Defrise and R. Clack, A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection, IEEE Trans. Med. Imag., vol. 13, pp , [6] M. Defrise, F. Noo, and H. Kudo, A solution to the long-object problem in helical cone-beam tomography, Phys. Med. Biol., vol. 45, pp , [7] H. Erdogan and J. A. Fessler, Accelerated monotonic algorithms for transmission tomography, in Proc. IEEE Int. Conf. Image Processing, vol. 2, 1998, pp [8] L. A. Feldkamp, L. C. Davis, and J. W. Kress, Practical cone-beam algorithm, J. Opt. Soc. Amer., vol. 1, pp , [9] J. A. Fessler, Hybrid poisson/polynomial objective functions for tomographic image reconstruction from transmission scans, IEEE Trans. Image Processing, vol. 4, pp , [10] J. A. Fessler, E. P. Ficaro, N. H. Clinthorne, and K. Lange, Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction, IEEE Trans. Med. Imag., vol. 16, pp , [11] J. A. Fessler, Statistical image reconstruction methods for transmission tomography, in SPIE Handbook of Medical Imaging, M. Sonka and J. M. Fitzpatric, Eds. Bellingham, WA: SPIE, vol. 3. [12] T. Fuchs, M. Kachelrieß, and W. A. Kalender, Direct comparison of a xenon and a solid state CT detector system: Measurements under working conditions, IEEE Trans. Med. Imag., vol. 19, pp , [13] T. Fuchs, J. Krause, S. Schaller, T. Flohr, and W. A. Kalender, Spiral interpolation algorithms for multislice spiral CT Part II: Measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system, IEEE Trans. Med. Imag., vol. 19, pp , [14] P. Grangeat, Analyze d un systèeme d Imagerie 3D par reconstruction à partir de radiographies X en gèomètrie conique, Thèse de doctorat, Ecole Nationale Supèrieure des Tèlècommunications, [15] M. Grass, T. Köhler, and R. Proksa, 3D cone-beam CT reconstruction for circular trajectories, Phys. Med. Biol., vol. 45, pp , [16] J. Hsieh, Tomographic reconstruction for tilted helical multislice CT, IEEE Trans. Med. Imag., vol. 19, pp , [17] J. Hsieh, O. E. Gurmen, and K. F. King, Investigation of a solid state detector for advanced computed tomography, IEEE Trans. Med. Imag., vol. 19, pp , [18] H. Hu, Multi-slice helical CT: Scan and reconstruction, Med. Phys., vol. 26, pp. 5 18, [19] M. Kachelrieß, S. Ulzheimer, and W. A. Kalender, ECG-correlated imaging of the heart with subsecond multi-slice spiral CT, IEEE Trans. Med. Imag., vol. 19, pp , [20] H. Kudo, F. Noo, and M. Defrise, Cone-beam filtered-backprojection algorithm for truncated helical data, Phys. Med. Biol., vol. 43, pp , [21], Quasi-exact filtered backprojection algorithm for long-object problem in helical cone-beam tomography, IEEE Trans. Med. Imag., vol. 19, pp , [22] K. Lange and R. Carson, EM reconstruction algorithms for emission and transmission tomography, J. Comput. Assisted Tomogr., vol. 8, pp , [23] K. Lange and J. A. Fessler, Globally convergent algorithms for maximum a posteriori transmission tomography, IEEE Trans. Image Processing, vol. 4, pp , [24] G. L. Larson, C. C. Ruth, and C. R. Crawford, Nutating slice ct image reconstruction apparatus and method, U.S. Patent , [25] R. Leahy and C. Byrne, Editorial: Recent development in iterative image reconstruction for PEET and SPECT, IEEE Trans. Med. Imag., vol. 19, pp , 2000.
4 820 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 19, NO. 9, SEPTEMBER 2000 [26] R. Ning, B. Chen, R. Yu, D. Conover, and Y. Ning, Flat panel detectorbased cone beam volume CT angiography imaging: System evaluation, IEEE Trans. Med. Imag., vol. 19, pp , [27] R. Proska, T. Köhler, M. Grass, and J. Timmer, The n-pi method for helical cone-beam CT, IEEE Trans. Med. Imag., vol. 19, pp , [28] S. Schaller, F. Noo, F. Sauer, K. C. Tam, G. Lauritsch, and T. Flohr, Exact radon rebinning algorithms using local regions-of-interest for helical cone-beam CT, in Proc Int. Mtg. on Fully 3D Image Reconsruction in Radiology and Nuclear Medicine, pp [29] S. Schaller, T. Flohr, K. Klingenbeck, J. Krause, T. Fuchs, and W. A. Kalender, Spiral interpolation algorithms for multi-slice spiral CT Part I: Theory, IEEE Trans. Med. Imag., vol. 19, pp , [30] M. D. Silver, High-helical pitch, cone-beam computed tomography, Phys. Med. Biol., vol. 43, pp , [31] B. D. Smith, Image reconstruction from cone-beam projections: Necessary and sufficient conditions and reconstruction methods, IEEE Trans. Med. Imag., vol. 4, pp , [32] D. L. Snyder, T. J. Schulz, and J. A. O Sullivan, Deblurring subject to nonnegativity constraints, IEEE Trans. Signal Processing, vol. 40, pp , [33] K. Taguchi and H. Aradate, Algorithm for image reconstruction in multi-slice helical CT, Med. Phys., vol. 25, pp , [34] K. Tam, Three-dimensional computerized tomography scanning method and system for large objects with smaller area detector, U.S. Patent , [35] K. C. Tam, S. Samarasekera, and F. Sauer, Exact cone-beam CT with a spiral scan, Phys. Med. Biol., vol. 43, pp , [36] K. C. Tam, B. Ladendorf, F. Sauer, and G. Lauritsch, Exact spiral scan region-of-interest cone beam reconstruction via backprojection, in Proc Int. Meeting Fully 3D Image Reconstruction in Radiology and Nuclear Medicine, pp [37] H. K. Tuy, An inversion formula for cone-beam reconstruction, SIAM J. Appl. Math., vol. 43, pp , [38] S. Wan, A. Kiraly, E. Ritman, and W. Higgins, Extraction of the hepatic vascularture in rats using 3-D micro-ct images, IEEE Trans. Med. Imag., vol. 19, pp , [39] G. Wang, T. H. Lin, P. C. Cheng, D. M. Shinozaki, and H. Kim, Scanning one-beam reconstruction algorithms for X-ray microtomography, SPIE Proc., vol. 1556, pp , [40] G. Wang, T. H. Lin, P. C. Cheng, and D. M. Shinozaki, A general cone-beam reconstruction algorithm, IEEE Trans. Med. Imag., vol. 12, pp , [41] G. Wang, Y. Liu, T. H. Lin, and P. C. Cheng, Half-scan cone-beam x-ray microtomography formula, J. Scanning Microscopy, vol. 16, pp , [42] G. Wang, D. L. Snyder, J. A. O Sullivan, and M. W. Vannier, Iterative deblurring for CT metal artifact reduction, IEEE Trans. Med. Imag., vol. 15, pp , [43] G. Wang, G. D. Schweiger, and M. W. Vannier, An iterative algorithm for X-ray CT fluoroscopy, IEEE Trans. Med. Imag., vol. 17, pp , [44] G. Wang, S. Y. Zhao, and P. C. Cheng, Exact and approximate cone-beam X-ray microtomography, in Modern Microscopies, P. C. Cheng, P. P. Huang, J. L. Wu, G. Wang, and H. G. Kim, Eds. New York: Springer-Verlag, 1999, vol. I. [45] X. H. Yan and R. M. Leahy, Cone beam tomography with circular, elliptical and spiral orbits, Phys. Med. Biol., vol. 37, pp , [46] S. Zhao and G. Wang, Feldkamp-type cone-beam tomography in the wavelet framework, IEEE Trans. Med. Imag., vol. 19, pp , Ge Wang (S 90 M 92 SM 00) received the B.Eng. degree in electrical engineering from Xidian University, Xian, China, in 1982, the M.S. degree in remote sensing from Graduate School of Academia Sinica, Beijing, China, in 1985, and the M.S. and Ph.D. degrees in electrical and computer engineering from the State University of New York at Buffalo in 1991 and 1992, respectively. He was Instructor and Assistant Professor with Department of Electrical Engineering Graduate School of Academia Sinica from 1984 to 1988, Instructor and Assistant Professor with Mallinckrodt Institute of Radiology Washington University, St. Louis, MO, from 1992 to He has been Associate Professor with Department of Radiology University of Iowa, Iowa City, since His interests are computed tomography (CT) and image analysis, with emphasis on spiral/helical CT. Dr. Wang serves as Associate Editor of Medical Physics, and published more than 70 refereed journal papers. His honors include the 1996 Hounsfield Award from the Society of Computed Body Tomography and Magnetic Resonance, the 1997 Giovanni DiChiro Award for Outstanding Scientific Research from the Journal of Computer Assisted Tomography, and the 1999 Medical Physics Travel Award from the American Association of Physicists in Medicine and the Institute of Physics and Engineering in Medicine. Carl R. Crawford (S 78 M 80 SM 95 F 97) received the B.S., M.S., and Ph.D. degrees in electrical engineering from Purdue University, West Lafayette, IN, in 1976, 1977, and 1981 respectively. He presented image quality improvements for ultrasonic transmission tomography in his dissertation. While with Elscint in Boston, MA, and in Haifa, Israel, from 1981 until 1983, he developed computerized tomographic reconstruction algorithms. Subsequently, he worked for 12 years at General Electric (GE) Medical Systems, Milwaukee, WI, as a Senior Physicist with the Applied Science Laboratory. At GE, he developed three-dimensional display and helical scanning packages for CT scanners and investigated methods for high-speed magnetic resonance imaging. In 1995, he joined Analogic Corporation, Peabody, MA, as Technical Vice President of Corporate Imaging Systems. At Analogic, he leads the application of signal and image processing techniques to medical and industrial CT scanners. He has 56 United States patents and 20 refereed journal articles. Dr. Crawford is an associate editor of IEEE TRANSACTIONS ON MEDICAL IMAGING.
5 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 19, NO. 9, SEPTEMBER Willi A. Kalender received the M.S. and Ph.D. degrees in medical physics from the University of Wisconsin, Madison, WI, in In 1988 he completed all postdoctoral lecturing qualifications (Habilitation) for Medical Physics at the University Tübingen, Tübingen, Germany. From 1979 to 1995, he worked in the research laboratories of Siemens Medical Systems, Erlangen, Germany, from 1988 to 1995 as Head of the Department of Medical Physics. Since 1991, he has been Adjunct Associate Professor of Medical Physics at the University of Wisconsin. From 1993 to 1995, he lectured at the Technical University of Munich, Munich, Germany. In 1995, he was appointed Full Professor and Director of the newly established Institute of Medical Physics at the Friedrich-Alexander-University Erlangen-Nürnberg, Germany. His main research interests lie in the area of diagnostic imaging; the development and introduction of volumetric spiral CT is a particular focus. His other fields of research are radiation protection and the development of quantitative diagnostic procedures, e.g., for assessment of osteoporosis, lung, and cardiac diseases.
A Grangeat-type half-scan algorithm for cone-beam CT
A Grangeat-type half-scan algorithm for cone-beam CT Seung Wook Lee a) CT/Micro-CT Lab., Department of Radiology, University of Iowa, Iowa City, Iowa 52242 and Department of Nuclear and Quantum Engineering,
The effect of pitch in multislice spiral/helical CT
The effect of pitch in multislice spiral/helical CT Ge Wang a) and Michael W. Vannier Department of Radiology, University of Iowa, Iowa City, Iowa 52242 Received 20 November 1998; accepted for publication
Cone Beam Reconstruction Jiang Hsieh, Ph.D.
Cone Beam Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced acquisition
Fundamentals of Cone-Beam CT Imaging
Fundamentals of Cone-Beam CT Imaging Marc Kachelrieß German Cancer Research Center (DKFZ) Heidelberg, Germany www.dkfz.de Learning Objectives To understand the principles of volumetric image formation
Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999
Spiral CT: Single and Multiple Detector Systems AAPM Refresher Course Nashville, TN July 28,1999 Mike McNitt-Gray, PhD, DABR Assistant Professor UCLA Radiological Sciences [email protected] X-Ray
Introduction to Medical Imaging. Lecture 11: Cone-Beam CT Theory. Introduction. Available cone-beam reconstruction methods: Our discussion:
Introduction Introduction to Medical Imaging Lecture 11: Cone-Beam CT Theory Klaus Mueller Available cone-beam reconstruction methods: exact approximate algebraic Our discussion: exact (now) approximate
Two years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions
Two years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions Laurent Desbat TIMC-IMAG, UMR 5525, Grenoble University, France [email protected] Rolf
MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington
MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical
CT Image Reconstruction. Terry Peters Robarts Research Institute London Canada
CT Image Reconstruction Terry Peters Robarts Research Institute London Canada 1 Standard X-ray Views Standard Radiograph acquires projections of the body, but since structures are overlaid on each other,
How To Improve Your Ct Image Quality
Translating Protocols Between Scanner Manufacturer and Model Cynthia H. McCollough, PhD, FACR, FAAPM Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo
CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E.
1 Overview CT scanning By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E. Wilhjelm) As it can be imagined, planar X-ray imaging has
Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction
Digital Industrial Radiology and Computed Tomography (DIR 2015) 22-25 June 2015, Belgium, Ghent - www.ndt.net/app.dir2015 More Info at Open Access Database www.ndt.net/?id=18046 Computed Tomography Resolution
Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data
INSTITUTE OF PHYSICS PUBLISHING Phys. Med. Biol. 49 (2004) 5489 5503 PHYSICS IN MEDICINE AND BIOLOGY PII: S0031-9155(04)85042-5 Fan-beam and cone-beam image reconstruction via filtering the backprojection
Purchasing a cardiac CT scanner: What the radiologist needs to know
Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London [email protected] CT scanner development Slice wars 1998 Increased z-coverage
State-of-the-Art Technology in Cardiac CT
1 2 Next Step Evolution or Revolution? State-of-the-Art Technology in Cardiac CT Stefan Ulzheimer, PhD Global Director of Collaborations CT Siemens Medical Solutions Major Innovations in CT Head The 80
An iterative approach to the beam hardening correction in cone beam CT
An iterative approach to the beam hardening correction in cone beam CT Jiang Hsieh a) Applied Science Laboratory, GE Medical Systems, Milwaukee, Wisconsin 53201 Robert C. Molthen Department of Biomedical
PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Medical and Industrial Tomography - W.B.Gilboy
MEDICAL AND INDUSTRIAL TOMOGRAPHY Department of Physics, University of Surrey, Guildford, Surrey, U.K. Keywords: Radiography, transmission tomography, emission tomography, microtomography, SPECT (single
BrightView XCT flat-panel cone-beam CT with iterative reconstruction for localization and attenuation correction
BrightView XCT flat-panel cone-beam CT with iterative reconstruction for localization and attenuation correction E. Hansis, PhD, A. Da Silva, PhD, H. Hines, PhD, J. Garrard, D. Sowards-Emmerd, PhD, and
Computerized Tomography, X-rays, and the Radon Transform
1 Computerized Tomography, X-rays, and the Radon Transform 1.1 Introduction The purpose of this chapter is to give an informal introduction to the subject of tomography. There are very few mathematical
Concepts for High-Resolution Low-Dose CT of the Breast
RSNA 2012 Refresher Course 721B, Chicago, Nov. 30, 2012 Concepts for High-Resolution Low-Dose CT of the Breast Disclosures WAK is founder, shareholder and CEO of CT Imaging GmbH, Erlangen, Germany. Willi
The Combination Forecasting Model of Auto Sales Based on Seasonal Index and RBF Neural Network
, pp.67-76 http://dx.doi.org/10.14257/ijdta.2016.9.1.06 The Combination Forecasting Model of Auto Sales Based on Seasonal Index and RBF Neural Network Lihua Yang and Baolin Li* School of Economics and
Review of Parallel Computing Techniques for Computed Tomography. Image Reconstruction
Review of Parallel Computing Techniques for Computed Tomography Image Reconstruction Jun Ni 1, 3, Xiang Li 2, Tao He 3, Ge Wang 1,2 1 Medical Imaging High Performance Computing Lab, Department of Radiology,
Multislice CT: Current Technology and Future Developments
Multislice CT: Current Technology and Future Developments 1 Stefan Ulzheimer and Thomas Flohr Contents 1.1 Introduction 3 1.2 System Design 5 1.2.1 Gantry 6 1.2.2 X-Ray Tube and Generator 6 1.2.3 MDCT
High Quality Image Magnification using Cross-Scale Self-Similarity
High Quality Image Magnification using Cross-Scale Self-Similarity André Gooßen 1, Arne Ehlers 1, Thomas Pralow 2, Rolf-Rainer Grigat 1 1 Vision Systems, Hamburg University of Technology, D-21079 Hamburg
Combining an Alternating Sequential Filter (ASF) and Curvelet for Denoising Coronal MRI Images
Contemporary Engineering Sciences, Vol. 5, 2012, no. 2, 85-90 Combining an Alternating Sequential Filter (ASF) and Curvelet for Denoising Coronal MRI Images Mohamed Ali HAMDI Ecole Nationale d Ingénieur
Automation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Automation of a CT Acquisition: A System-based User-Support More Info at Open Access Database
Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm
Progress In Electromagnetics Research Symposium Proceedings, Taipei, March 5 8, 3 359 Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm Yoshito Sonoda, Takashi Samatsu, and
High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound
High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound Ralf Bruder 1, Florian Griese 2, Floris Ernst 1, Achim Schweikard
CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions
CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions Frank N. Ranallo, Ph.D. Associate Professor of Medical Physics & Radiology University of Wisconsin School of
Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.
1 12/9/2008 Page 1 Master s Program in Medical Physics Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III Chair in Faculty of Medicine Mannheim University of Heidelberg Theodor-Kutzer-Ufer
Basics of Clinical X-Ray Computed Tomography
Siemens 3=18-slice dual source cone-beam spiral CT (005) Basics of Clinical X-Ra Computed Tomograph EMI parallel beam scanner (197) Marc Kachelrieß Institute of Medical Phsics Universit of Erlangen-Nürnberg
Multi Detector Row CT Systems and Image- Reconstruction Techniques 1
Special Review Radiology Thomas G. Flohr, PhD Stefan Schaller, PhD Karl Stierstorfer, PhD Herbert Bruder, PhD Bernd M. Ohnesorge, PhD U. Joseph Schoepf, MD Published online before print 10.1148/radiol.2353040037
Lecture 14. Point Spread Function (PSF)
Lecture 14 Point Spread Function (PSF), Modulation Transfer Function (MTF), Signal-to-noise Ratio (SNR), Contrast-to-noise Ratio (CNR), and Receiver Operating Curves (ROC) Point Spread Function (PSF) Recollect
CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH
CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology
Super-Resolution Reconstruction in MRI: Better Images Faster?
Super-Resolution Reconstruction in MRI: Better Images Faster? Esben Plenge 1,, Dirk H. J. Poot 1, Monique Bernsen 2, Gyula Kotek 2, Gavin Houston 2, Piotr Wielopolski 2, Louise van der Weerd 3, Wiro J.
MEDICAL IMAGING 2nd Part Computed Tomography
MEDICAL IMAGING 2nd Part Computed Tomography Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional
4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.
4D Scanning Steve B. Jiang, Ph.D. Department of Radiation Oncology [email protected] http://gray.mgh.harvard.edu/ Outline Problems with free breathing 3D scanning What is 4D CT? How does it work?
The promise of ultrasonic phased arrays and the role of modeling in specifying systems
1 modeling in specifying systems ABSTRACT Guillaume Neau and Deborah Hopkins This article illustrates the advantages of phased-array systems and the value of modeling through several examples taken from
PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors
Quality Control in PET PET/CT QC/QA Magnus Dahlbom, Ph.D. Division of Nuclear Medicine Ahmanson Biochemical Imaging Clinic David Geffen School of Medicine at UCLA Los Angeles Verify the operational integrity
THEORY, SIMULATION, AND COMPENSATION OF PHYSIOLOGICAL MOTION ARTIFACTS IN FUNCTIONAL MRI. Douglas C. Noll* and Walter Schneider
THEORY, SIMULATION, AND COMPENSATION OF PHYSIOLOGICAL MOTION ARTIFACTS IN FUNCTIONAL MRI Douglas C. Noll* and Walter Schneider Departments of *Radiology, *Electrical Engineering, and Psychology University
R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.
R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction
Fast cone-beam CT image reconstruction using GPU hardware
Journal of X-Ray Science and Technology 16 (2008) 225 234 225 IOS Press Fast cone-beam CT image reconstruction using GPU hardware Guorui Yan, Jie Tian, Shouping Zhu, Yakang Dai and Chenghu Qin Medical
X-Rays Benefits and Risks. Techniques that use x-rays
X-Rays Benefits and Risks X-rays are a form of electromagnetic radiation, just like light waves and radiowaves. Because X-rays have higher energy than light waves, they can pass through the body. X-rays
GE Healthcare. DoseWatch. Gathering Radiation Dose Data
GE Healthcare DoseWatch Gathering Radiation Dose Data Gathering Radiation Dose Data After your organization crosses the bridge of Why? for patient radiation dose management either due to regulation, risk
Multi-slice CT Technology 3
41 Multi-slice CT Technology 3 Thomas Flohr and Bernd Ohnesorge Contents 3.1 Evolution from 1 to 64 Slices 41 3.2 Principles of Multi-slice CT System Design 45 3.3 Multi-slice CT Acquisition and Reconstruction
How To Fix Out Of Focus And Blur Images With A Dynamic Template Matching Algorithm
IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 10 April 2015 ISSN (online): 2349-784X Image Estimation Algorithm for Out of Focus and Blur Images to Retrieve the Barcode
Image Area. View Point. Medical Imaging. Advanced Imaging Solutions for Diagnosis, Localization, Treatment Planning and Monitoring. www.infosys.
Image Area View Point Medical Imaging Advanced Imaging Solutions for Diagnosis, Localization, Treatment Planning and Monitoring www.infosys.com Over the years, medical imaging has become vital in the early
European Academy of DentoMaxilloFacial Radiology
European Academy of DentoMaxilloFacial Radiology Framework for Specialist Training in Dental and Maxillofacial Radiology Background The scope of DentoMaxilloFacial Radiology DMFR (Dental and Maxillofacial
IBA Proton Therapy. Biomed days 2015. Vincent Bossier. System Architect [email protected]. Protect, Enhance and Save Lives
Vincent Bossier System Architect [email protected] IBA Proton Therapy Biomed days 2015 Protect, Enhance and Save Lives 1 Agenda AN INTRODUCTION TO IBA WHY PROTON THERAPY CLINICAL WORKFLOW TREATMENT
Monitoring Patient Radiation Dose in VA. Charles M. Anderson MD, PhD Chief Consultant for Diagnostic Services Veterans Health Administration
Monitoring Patient Radiation Dose in VA Charles M. Anderson MD, PhD Chief Consultant for Diagnostic Services Veterans Health Administration TWENTY ONE/NOVEMBER 2011 Computed Tomography (CT), Magnetic Resonance
5 Factors Affecting the Signal-to-Noise Ratio
5 Factors Affecting the Signal-to-Noise Ratio 29 5 Factors Affecting the Signal-to-Noise Ratio In the preceding chapters we have learned how an MR signal is generated and how the collected signal is processed
Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center
Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster Jesse Garant, JG&A Metrology Center Traditional Metrology and Inspection Tactile Devices (Touch Probe)
A Three-Dimensional Correlation Method for Registration of Medical Images in Radiology
A Three-Dimensional Correlation Method for Registration of Medical Images in Radiology Michalakis F. Georgiou 1, Joachim H. Nagel 2, George N. Sfakianakis 3 1,3 Department of Radiology, University of Miami
Physics testing of image detectors
Physics testing of image detectors Parameters to test Spatial resolution Contrast resolution Uniformity/geometric distortion Features and Weaknesses of Phantoms for CR/DR System Testing Dose response/signal
Development of SCENARIA New Version Software MEDIX VOL. 62 P.32 P.35
Development of SCENAIA New Version Software Takayuki Kadomura Toshio Sakamoto Kana Tanaka Takatsugu Ito Yuuko Nishimura Naomi Maekawa MEDIX VOL. 62 P.32 P.35 Development of SCENAIA New Version Software
Computed Tomography. 62.1 Instrumentation. Ian A. Cunningham. Data-Acquisition Geometries. Ian A. Cunningham
62 Computed Tomography Ian A. Cunningham Victoria Hospital, the John P. Robarts Research Institute, and the University of Western Ontario Philip F. Judy Brigham and Women s Hospital and Harvard Medical
THE Walsh Hadamard transform (WHT) and discrete
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I: REGULAR PAPERS, VOL. 54, NO. 12, DECEMBER 2007 2741 Fast Block Center Weighted Hadamard Transform Moon Ho Lee, Senior Member, IEEE, Xiao-Dong Zhang Abstract
CT artifacts: Causes and reduction techniques
F Edward Boas & Dominik Fleischmann* Department of Radiology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA 94305, USA *Author for correspondence: Tel.: +1 650 723 7647 [email protected]
Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose
Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose ipatient is an advanced platform that delivers focused innovations to facilitate patient-centered
Development of High Speed Oblique X-ray CT System for Printed Circuit Board
計 測 自 動 制 御 学 会 産 業 論 文 集 Vol. 6, No. 9, 72/77 (2007) Development of High Speed Oblique X-ray CT System for Printed Circuit Board Atsushi TERAMOTO*, Takayuki MURAKOSHI*, Masatoshi TSUZAKA**, and Hiroshi
096 Professional Readiness Examination (Mathematics)
096 Professional Readiness Examination (Mathematics) Effective after October 1, 2013 MI-SG-FLD096M-02 TABLE OF CONTENTS PART 1: General Information About the MTTC Program and Test Preparation OVERVIEW
GUIDE TO SETTING UP AN MRI RESEARCH PROJECT
GUIDE TO SETTING UP AN MRI RESEARCH PROJECT Formal requirements and procedures OVERVIEW This document is intended to help a principle investigator set up a research project using magnetic resonance imaging
MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM
MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM João Antônio Palma Setti, [email protected] Pontifícia Universidade Católica do Paraná / Rua Imaculada
Computer Aided Liver Surgery Planning Based on Augmented Reality Techniques
Computer Aided Liver Surgery Planning Based on Augmented Reality Techniques Alexander Bornik 1, Reinhard Beichel 1, Bernhard Reitinger 1, Georg Gotschuli 2, Erich Sorantin 2, Franz Leberl 1 and Milan Sonka
Medical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute [email protected].
Medical Image Processing on the GPU Past, Present and Future Anders Eklund, PhD Virginia Tech Carilion Research Institute [email protected] Outline Motivation why do we need GPUs? Past - how was GPU programming
WAVELET ANALYSIS BASED ULTRASONIC NONDESTRUCTIVE TESTING OF POLYMER BONDED EXPLOSIVE
WAVELET ANALYSIS BASED ULTRASONIC NONDESTRUCTIVE TESTING OF POLYMER BONDED EXPLOSIVE Weibin Zhang, Yong Tian, Zhanfeng Yang, Liling Wang Institute of Chemical Materials, China Academy of Engineering Physics,
Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study
Feasibility Study of Neutron Dose for Real Time Image Guided Proton Therapy: A Monte Carlo Study Jin Sung Kim, Jung Suk Shin, Daehyun Kim, EunHyuk Shin, Kwangzoo Chung, Sungkoo Cho, Sung Hwan Ahn, Sanggyu
IGRT. IGRT can increase the accuracy by locating the target volume before and during the treatment.
DERYA ÇÖNE RADIOTHERAPY THERAPIST ACIBADEM KOZYATAGI HOSPITAL RADIATION ONCOLOGY DEPARTMENT IGRT IGRT (image-guided radiation therapy) is a technique that reduces geometric uncertainties by considering
Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.
Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation. Andrew Bridges Clinical Scientist Diagnostic Radiology & Radiation Protection Physics Overview What is CBCT? Use of CBCT
The Periodic Moving Average Filter for Removing Motion Artifacts from PPG Signals
International Journal The of Periodic Control, Moving Automation, Average and Filter Systems, for Removing vol. 5, no. Motion 6, pp. Artifacts 71-76, from December PPG s 27 71 The Periodic Moving Average
Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays
J. E. Wilhjelm Ørsted TU Technical University of enmark, Bldg. 348, K-2800 Kongens Lyngby, enmark. X-ray and Computed Tomography Contents History and characterization of X-rays Conventional (projection)
CHAPTER 7 CONCLUSION AND FUTURE WORK
158 CHAPTER 7 CONCLUSION AND FUTURE WORK The aim of this thesis was to present robust watermarking techniques for medical image. Section 7.1, consolidates the contributions made by the researcher and Section
ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.
ParaVision 6 The Next Generation of MR Acquisition and Processing for Preclinical and Material Research Innovation with Integrity Preclinical MRI A new standard in Preclinical Imaging ParaVision sets a
DIGITAL IMAGE PROCESSING AND ANALYSIS
DIGITAL IMAGE PROCESSING AND ANALYSIS Human and Computer Vision Applications with CVIPtools SECOND EDITION SCOTT E UMBAUGH Uffi\ CRC Press Taylor &. Francis Group Boca Raton London New York CRC Press is
How To Analyze Ball Blur On A Ball Image
Single Image 3D Reconstruction of Ball Motion and Spin From Motion Blur An Experiment in Motion from Blur Giacomo Boracchi, Vincenzo Caglioti, Alessandro Giusti Objective From a single image, reconstruct:
QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET
Centers for Quantitative Imaging Excellence (CQIE) LEARNING MODULE QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET American College of Radiology Clinical Research Center v.1 Centers for Quantitative
Latest Results on High-Resolution Reconstruction from Video Sequences
Latest Results on High-Resolution Reconstruction from Video Sequences S. Lertrattanapanich and N. K. Bose The Spatial and Temporal Signal Processing Center Department of Electrical Engineering The Pennsylvania
Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives
Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives Gilbert W. Beebe Symposium The National Academies Katharine Grant, PhD Staff Scientist 8 December 2011 For internal
CURRICULUM VITAE. Kalpana M. Kanal, Ph.D., DABR
May 31, 2005 ADDRESS: PERSONAL: CURRICULUM VITAE Kalpana M. Kanal, Ph.D., DABR Department of Radiology University of Washington Medical Center 1959 NE Pacific Avenue Seattle, WA 98195-7115 (206) 616-1966
Using a flat-panel detector in high resolution cone beam CT for dental imaging
(2004) 33, 285 290 q 2004 The British Institute of Radiology http://dmfr.birjournals.org RESEARCH Using a flat-panel detector in high resolution cone beam CT for dental imaging R Baba*,, K Ueda 2 and M
IAEA HUMAN HEALTH SERIES
IAEA HUMAN HEALTH SERIES No. 19 Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications IAEA HUMAN HEALTH SERIES PUBLICATIONS The mandate of the IAEA human health programme
An introduction to OBJECTIVE ASSESSMENT OF IMAGE QUALITY. Harrison H. Barrett University of Arizona Tucson, AZ
An introduction to OBJECTIVE ASSESSMENT OF IMAGE QUALITY Harrison H. Barrett University of Arizona Tucson, AZ Outline! Approaches to image quality! Why not fidelity?! Basic premises of the task-based approach!
Cynthia H. McCollough b) and Michael R. Bruesewitz Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905
The phantom portion of the American College of Radiology ACR Computed Tomography CT accreditation program: Practical tips, artifact examples, and pitfalls to avoid a Cynthia H. McCollough b) and Michael
A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator
UCRL-CONF-236077 A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator G. J. Caporaso, T. R. Mackie, S. Sampayan, Y. -J. Chen, D. Blackfield, J. Harris, S. Hawkins, C. Holmes, S. Nelson,
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer
Multislice Computed Tomography: Basic Principles and Clinical Applications
New Applications with the Assistance of Innovative Technologies Multislice Computed Tomography: Basic Principles and Clinical Applications A. F. Kopp, K. Klingenbeck-Regn 2, M. Heuschmid, A. Küttner, B.