DeviceNet, Panel Mount Junction Box
|
|
|
- Amber Roberts
- 9 years ago
- Views:
Transcription
1 DeviceNet, Panel Mount Junction Box DIN Rail Junction Box Open Style Removable Terminals Part Number Application Wiring Diagrams JRBS-57-4 JRBS-57-6 Open style DIN mounted junction box JRBS-57-8
2 Specifications Housing: Aluminum Contact Carrier: PA (Nylon) Contacts: Gold Plated CuZn Protection: NEMA 1 and IP 20 Connection Mode: Snap-on DIN RAIL (DIN 50022) Ambient Temperature: -25 to +70 C (-13 to +158 F) 4-Port 6-Port DeviceNet Media 8-Port
3 DeviceNet, eurofast Junctions Multi-port Junction Boxes for Connecting I/O in Concentrated Areas Available in Standard and Voltage Monitoring Part Number Application Wiring Diagram 8-port Junction with Voltage Monitoring JBBS-57-E811 Bus in/bus out connections (7/8-16UN) minifast Eight (M12x1) eurofast connectors for field connectors Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber 8-port Junction JBBS-57-E812 Bus in/bus out connections (7/8-16UN) minifast Eight (M12x1) eurofast connectors for field connectors
4 Specifications Housing: POM (Nylon) Coupling Nut: Nickel Plated CuZn or Stainless Steel Contact Carrier: Nylon Contacts: Gold Plated CuZn Protection: NEMA 1, 3, 4, 6P and IEC IP 68 Rated Voltage: 250 V Rated Current: 4A Ambient Temperature: -40 to +75 C (-22 to +167 F) Dimensions 8-port DeviceNet Media Male minifast Pinouts Female eurofast Female
5 DeviceNet, picofast Junctions, 4-port Multi-Port Passive Junction Box in Small Compact Housing Accepts (M8x1) Snap Lock or Threaded Connectors Available in Standard and Voltage Monitoring Part Number Application Wiring Diagrams 4-port Junction Tee JBBS-57-FS-P424Z (M12x1) eurofast drop connector Four (M8x1) picofast snap lock connectors 4-port Junction Tee JBBS-57-FS-P424M (M12x1) eurofast drop connector Four (M8x1) picofast threaded connectors 4-port Junction Tee JBBS-57-FS/VM-P424Z (M12x1) eurofast drop connector Four (M8x1) picofast snap lock connectors Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED Indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber 4-port Junction Tee JBBS-57-FS/VM-P424M (M12x1) eurofast drop connector Four (M8x1) picofast threaded connectors Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber JBBS-57-FS-E424 4-port Junction Tee (M12x1) eurofast drop connector Four (M12x1) eurofast threaded connectors
6 Specifications Housing: POM (Nylon) Coupling Nut: Nickel Plated CuZn or Stainless Steel Contact Carrier: PUR (Polyurethane) or POM (Nylon)-picofast, POM (Nylon)-eurofast Contacts: Gold Plated CuZn Protection: NEMA 1, 3, 4, 6P and IEC IP 67 Rated Voltage: 30 V Rated Current: 1.5 A Ambient Temperature: -40 to +75 C (-22 to +167 F) JBBS-57-FS-P424Z JBBS-57-FS-P424M DeviceNet Media JBBS-57-FS-E424 eurofast Male picofast Pinouts picofast eurofast Pinouts eurofast Male 1. Bare (Shield Drain Wire) 2. Red (+ Voltage) 3. Black (- Voltage) 4. White (CAN_H) 5. Blue (CAN_L) 6. N/C (picofast only) Female Male 1. = (Shield Drain Wire) 2. = (+ Voltage) 3. = (- Voltage) 4. = (CAN_H) 5. = (CAN_L) Female
7 DeviceNet, picofast Junctions, 8-port Multi-Port Passive Junction Box in Small Compact Housing Accepts (M8x1) Snap Lock or Threaded Connectors Available in Standard and Voltage Monitoring Part Number Application Wiring Diagrams JBBS-57-FS-P824Z 8-port Junction Tee (M12x1) eurofast drop connector Eight (M8x1) picofast snap lock connectors JBBS-57-FS-P824M 8-port Junction Tee (M12x1) eurofast drop connector Eight (M8x1) picofast threaded connectors 8-port Junction Tee JBBS-57-FS/VM-P824Z (M12x1) eurofast drop connector Eight (M8x1) picofast snap lock connectors Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber 8-port Junction Tee JBBS-57-FS/VM-P824M (M12x1) eurofast drop connector Eight (M8x1) picofast threaded connectors Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber
8 Specifications Housing: POM (Nylon) Coupling Nut: Nickel Plated CuZn or Stainless Steel Contact Carrier: PUR (Polyurethane) or POM (Nylon)-picofast, POM (Nylon)-eurofast Contacts: Gold Plated CuZn Protection: NEMA 1, 3, 4, 6P and IEC IP 67 Rated Voltage: 30 V Rated Current: 1.5 A Ambient Temperature: -40 to +75 C (-22 to +167 F) JBBS-57-FS-P824Z DeviceNet Media JBBS-57-FS-P824M picofast Pinouts picofast Male 1. Bare (Shield Drain Wire) 2. Red (+ Voltage) 3. Black (- Voltage) 4. White (CAN_H) 5. Blue (CAN_L) 6. N/C (picofast only) Female
9 DeviceNet, minifast Passive Multi-Port Junctions Rugged, Fully Encapsulated Enclosure For Connecting I/O in Concentrated Areas Bus-In / Bus-Out Eliminates Need for Splitter Tee Suitable for Outdoor Applications Part Number Specs Application Wiring Diagrams JBBS-57-M401 JBBS-57-M413 4-port Junction Bus in/bus out straight (7/8-16UN) minifast through ports Four device ports with (7/8-16UN) minifast connectors JBBS-57-M601 JBBS-57-M613 Die-cast aluminum enclosure. 6-port Junction Bus in/bus out straight (7/8-16UN) minifast through ports Six device ports with (7/8-16UN) minifast connectors JBBS-57-M801 JBBS-57-M813 8-port Junction Bus in/bus out straight (7/8-16UN) minifast through ports Eight device ports with (7/8-16UN) minifast connectors
10 Specifications Housing: Coupling Nut: Contact Carrier: Contacts: Protection: Rated Voltage: Rated Current: Ambient Temperature: Anodized Aluminum Nickel Plated CuZn or Stainless Steel TPU (Polyurethane) or POM (Nylon) Gold Plated CuZn NEMA 1, 3, 4, 6P and IEC IP 67, IP 68, IP 69K 250 V 9A -40 to +75 C (-22 to +167 F) 8-Port Dimensions 6-Port DeviceNet Media 4-Port Pinouts minifast Male Female
11 DeviceNet, minifast Passive Multi-Port Junctions Rugged, Fully Encapsulated Enclosure For Connecting I/O in Concentrated Areas Bus-In / Bus-Out Eliminates Need for Splitter Tee Suitable for Outdoor Applications Part Number Specs Application Wiring Diagrams JBBS-57-M623 Fiberglass enclosure 6-port Junction Bus in/bus out straight (7/8-16UN) minifast through ports Six device ports with (7/8-16UN) minifast connectors
12 Specifications Housing: Coupling Nut: Contact Carrier: Contacts: Protection: Rated Voltage: Rated Current: Ambient Temperature: Fiberglass Nickel Plated CuZn or Stainless Steel TPU (Polyurethane) or POM (Nylon) Gold Plated CuZn NEMA 1, 3, 4, 6P and IEC IP 67, IP 68, IP 69K 250 V 9A -40 to +75 C (-22 to +167 F) Dimensions DeviceNet Media 6-Port Pinouts minifast Male Female
13 DeviceNet, eurofast Passive Multi-Port Junctions Rugged, Fully Encapsulated Enclosure For Connecting I/O in Concentrated Areas Bus-In / Bus-Out Eliminates Need for Splitter Tee Suitable for Outdoor Applications Part Number Specs Application Wiring Diagram JBBS-57-E401 JBBS-57-E403 JBBS-57-E411 Die-cast aluminum enclosure. 4-port Junction Bus in/bus out straight (7/8-16UN) minifast through ports Four device ports with (M12x1) eurofast connectors JBBS-57-E421 Fiberglass JBBS-57-E601 Die-cast aluminum enclosure. JBBS-57-E621 Fiberglass 6-port Junction Bus in/bus out straight (7/8-16UN) minifast through ports Six device ports with (M12x1) eurofast connectors
14 Specifications Housing: Coupling Nut: Contact Carrier: Contacts: Protection: Rated Voltage: Rated Current: Ambient Temperature: Anodized Aluminum/Fiberglass Nickel Plated CuZn or Stainless Steel TPU (Polyurethane) or POM (Nylon) Gold Plated CuZn NEMA 1, 3, 4, 6P and IEC IP 67, IP 68, IP 69K 250 V 4A -40 to +75 C (-22 to +167 F) Dimensions DeviceNet Media 4-Port 6-Port Pinouts eurofast Male Female
15 DeviceNet, eurofast Passive Multi-Port Junctions Rugged, Fully Encapsulated Enclosure For Connecting I/O in Concentrated Areas Bus-In / Bus-Out Eliminates Need for Splitter Tee Suitable for Outdoor Applications Part Number Specs Application Wiring Diagram JBBS-57-E801 JBBS-57-E803 Die-cast aluminum enclosure. 8-port Junction Bus in/bus out straight (7/8-16UN) minifast through ports Eight device ports with (M12x1) eurofast connectors JBBS-57-E821 Fiberglass
16 Specifications Housing: Coupling Nut: Contact Carrier: Contacts: Protection: Rated Voltage: Rated Current: Ambient Temperature: Anodized Aluminum/Fiberglass Nickel Plated CuZn or Stainless Steel TPU (Polyurethane) or POM (Nylon) Gold Plated CuZn NEMA 1, 3, 4, 6P and IEC IP 67, IP 68, IP 69K 250 V 4A -40 to +75 C (-22 to +167 F) Dimensions DeviceNet Media 8-Port Pinouts eurofast Male Female
17 DeviceNet, eurofast Passive Multi-Port Junctions Rugged, Fully Encapsulated Enclosure For Connecting I/O in Concentrated Areas Bus-In / Bus-Out Eliminates Need for Splitter Tee Suitable for Outdoor Applications Part Number Specs Application Wiring Diagram 10-port Junction JBBS-57-E1001 Die-cast aluminum enclosure. Bus in/bus out straight (7/8-16UN) minifast through ports Ten device ports with (M12x1) eurofast connectors
18 Specifications Housing: Coupling Nut: Contact Carrier: Contacts: Protection: Rated Voltage: Rated Current: Ambient Temperature: Anodized Aluminum Nickel Plated CuZn or Stainless Steel TPU (Polyurethane) or POM (Nylon) Gold Plated CuZn NEMA 1, 3, 4, 6P and IEC IP 67, IP 68, IP 69K 250 V 4A -40 to +75 C (-22 to +167 F) Dimensions DeviceNet Media 10-Port Pinouts eurofast Male Female
19 DeviceNet, eurofast Passive Multi-Port Junctions Switchable DeviceNet Diagnostic Box Used fo DeviceNet Troubleshooting Part Number Specs Application Wiring Diagram Diagnostic Box JBBS-57-DGM Fiberglass Taps into CAN_H, CAN_L, V+, V- and SHIELD Used to diagnose DeviceNet (should not be installed permanently on network)
20 Specifications Housing: Coupling Nut: Contact Carrier: Contacts: Protection: Rated Voltage: Rated Current: Ambient Temperature: Fiberglass Nickel Plated CuZn or Stainless Steel TPU (Polyurethane) or POM (Nylon) Gold Plated CuZn IEC IP V 4A -40 to +75 C (-22 to +167 F) Dimensions DeviceNet Media DGM Pinouts eurofast Male minifast Male minifast Female
21 DeviceNet, eurofast Passive Multi-Port Junctions System Module Junction Box Part Number Specs Application Wiring Diagram Bus In Power V- V+ Left V+ Right V System module with two circuit groups Shield 1 1 Shield JBBS-57-SM01 Die-cast aluminum enclosure. DeviceNet circuit Supplies DC power Two drops Auxiliary power Supplies DC power Catagory 2 E-stop General purpose M(machine)-stop Trunk Left Shield E-Stop Aux. Left V+ Left 2 V- 3 CAN_H 4 CAN_L 5 Shield 1 Shield 2 Shield 3 Shield 4 Shield 5 E-stop+ R 2 E-stop- R 1 E-stop- L 4 E-stop+ L 3 E-stop+ L 2 E-stop- L 3 Aux.+ L 1 Aux.- L V+ Right V- CAN_H CAN_L Shield V+ Right V- CAN_H CAN_L Shield V+ Right V- CAN_H CAN_L E-stop+ R E-stop- R Aux.+ R Aux.- R Trunk Right Local Bus Local Bus Aux. Right Aux.- R Aux.+ R Aux.+ L Aux.- L Aux. In Power
22 Specifications Housing: Coupling Nut: Contact Carrier: Contacts: Protection: Rated Voltage: Rated Current: Ambient Temperature: Anodized Aluminum Nickel Plated CuZn or Stainless Steel TPU (Polyurethane) or POM (Nylon) Gold Plated CuZn NEMA 1, 3, 4, 6P and IEC IP 67, IP 68, IP 69K 250 V 4A -40 to +75 C (-22 to +167 F) Dimensions DeviceNet Media SM01
23 DeviceNet, minifast Junction Tee Indoor Use Only (for outdoor applications use JBBS family) Multi-Port Junction Provides a Rugged Connection to Network Devices Bus-in/Bus-out Feature Eliminates Need for Splitter Tee Part Number Application Wiring Diagrams 4-port Junction Tee JTBS 57-M433 (7/8-16UN) minifast bus in/bus out connections Four (7/8-16UN) minifast device ports For nickel plated brass connectors change part number to JTBS 57-M434 4-port Junction Tee JTBS 57VM-M433 (7/8-16UN) minifast bus in/bus out connections Four (7/8-16UN) minifast device ports For nickel plated brass connectors change part number to JTBS 57VM-M434 Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber CL I, Div 2; Groups A-D see TURCK drawing N T6, Ta = 70 C 6-port Junction Tee JTBS 57-M633 (7/8-16UN) minifast bus in/bus out connections Six (7/8-16UN) minifast device ports For nickel plated brass connectors change part number to JTBS 57-M634 6-port Junction Tee JTBS 57VM-M633 (7/8-16UN) minifast bus in/bus out connections Six (7/8-16UN) minifast device ports For nickel plated brass connectors change part number to JTBS 57VM-M634 Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber CL I, Div 2; Groups A-D see TURCK drawing N T6, Ta = 70 C
24 Specifications Housing: PUR (Polyurethane) Coupling Nut: Nickel Plated CuZn or Stainless Steel Contact Carrier: PUR (Polyurethane) or POM (Nylon) Contacts: Gold Plated CuZn Protection: NEMA 1, 3, 4, 6P and IEC IP 67 Rated Voltage: 300 V Rated Current: 9A Ambient Temperature: -40 to +75 C (-22 to +167 F) Dimensions 4-port 6-port DeviceNet Media Pinouts minifast Male Female
25 DeviceNet, eurofast Junction Tee Indoor Use Only (for outdoor applications use JBBS family) Multi-Port Junction Provides a Rugged Connection to Network Devices Bus-in/Bus-out Feature Eliminates Need for Splitter Tee Part Number Application Wiring Diagrams 4-port Junction Tee JTBS 57-E433 (7/8-16UN) minifast bus in/bus out connections Four (M12x1) eurofast device ports For nickel plated brass connectors change part number to JTBS 57-E434 4-port Junction Tee JTBS 57VM-E433 (7/8-16UN) minifast bus in/bus out connections Four (M12x1) eurofast device ports For nickel plated brass connectors change part number to JTBS 57VM-E434 Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber CL I, Div 2; Groups A-D see TURCK drawing N T6, Ta = 70 C 6-port Junction Tee JTBS 57-E633 (7/8-16UN) minifast bus in/bus out connections Six (M12x1) eurofast device ports For nickel plated brass connectors change part number to JTBS 57-E634 6-port Junction Tee JTBS 57VM-E633 (7/8-16UN) minifast bus in/bus out connections Six (M12x1) eurofast device ports For nickel plated brass connectors change part number to JTBS 57VM-E634 Voltage monitoring provides low voltage (12.9 V) and high voltage (25.6) indication LED indication: (Lo) < 12.9 V Amber (Ok) V Green (Hi) > 25.6 V Amber CL I, Div 2; Groups A-D see TURCK drawing N T6, Ta = 70 C
26 Specifications Housing: PUR (Polyurethane) Coupling Nut: Nickel Plated CuZn or Stainless Steel Contact Carrier: POM (Nylon) Contacts: Gold Plated CuZn Protection: NEMA 1, 3, 4, 6P and IEC IP 67 Rated Voltage: 250 V Rated Current: 4A Ambient Temperature: -40 to +75 C (-22 to +167 F) Dimensions 4-port 6-port DeviceNet Media Pinouts minifast eurofast Male Female Female
27 DeviceNet, eurofast Drop Junctions Creates a Drop or Branch from the Main Bus Line Cable Drop Lengths Available Up to a Maximum of 6 Meters Housing Part Number Application Wiring Diagrams VB2 Junction VB2-FKM/FKM/FSM 57 Ready for eurofast drop and trunk cordsets Maximum six meter drop VB2-RKC 57x-*M-FKM FSM VB2 Junction with Trunk Line Ready for eurofast trunk line Maximum six meter drop VB2-FKM/RKC RSC 57x-*M/*M VB2 Junction with Trunk Line Ready for eurofast drop cordsets Maximum six meter branch * Indicates length in meters. x Indicates cable type.
28 Specifications Housing: PUR (Polyurethane) Coupling Nut: Nickel Plated CuZn or Stainless Steel Contact Carrier: PUR (Polyurethane) or POM (Nylon) Contacts: Gold Plated CuZn Protection: NEMA 1, 3, 4, 6P and IEC IP 68 Rated Voltage: 250 V Rated Current: 4A Ambient Temperature: -40 to +75 C (-22 to +167 F) Mounting: Mounting hole accepts #8 screw. DeviceNet Media VB2-FKM/FKM/FSM 57 VB2-RKC 57x-*M-FKM FSM VB2-FKM/RKC RSC 57x-*M/*M Pinouts Male eurofast Female
DeviceNet, minifast Conduit Adapters
DeviceNet, minifast Conduit Adapters Gasket and Mounting Screws Provided Same Housing Style for Single or Double Port Housing Part Number Specs Application Pinout BCA 57-M123 conduit body* for transition
TURCK Modular Industrial I/O PROFIBUS -DP Products
TURCK Modular Industrial I/O PROFIBUS -DP Products Piconet Gateways Rugged, Fully Potted Stations IP 67 Protection Small Footprint Automatic Baud Rate Sensing SDPL-0404D-0003 SDPL-0404D-0004 SDPL-0404D-1003
Network Connectivity. Your link for dependable routing of signal and data in industrial environments
Network Connectivity Your link for dependable routing of signal and data in industrial environments LynxPOWER Industrial Connectivity Realize time and cost savings with LynxPOWER Industrial Connectivity
LED...A70..4-..Q Series Sealed High-Intensity
LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for
Valve Connector Products
Valve Connectors, Type A (18 mm) Available with, and Rubber Jacket 18 and AWG 2 Conductors + Ground, Ground Contacts Parallel Wired NRTL/C **All parts except E. A Style Valve Connectors, Standard Color
General 1-2-Opto-electronics Safety Switches 4-Emergency
General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a
14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. [email protected] - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
EPIC CIRCON M23 Series Circular Signal Connectors
Circular Signal Connectors CIRCON M2 circular signal connectors are designed to DIN specification N698 and have a standard M2 threaded connection housing. They are offered in coupler, connector, and panel
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Single sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
PROCESS AUTOMATION JUNCTION BOX SELECTION GUIDE FOR FIELDBUS INFRASTRUCTURE
PROCESS AUTOMATION JUNCTION BOX SELECTION GUIDE FOR FIELDBUS INFRASTRUCTURE ENCLOSURE SOLUTIONS FOR FIELDBUS DISTRIBUTION Delivering Solutions For the last 50 years, Pepperl+Fuchs has been a world leader
FASTON Terminals and Connectors
Introduction Product Facts Straight, right-angle and receptacle-tab combinations available Receptacles available for 6.3 mm, 4.8 mm and 2.8 mm tab size (.250,.187 and.110 Series) Receptacles mate with
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
Now Available in Black Zinc Nickel
847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
HARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
Digital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
400 Series Buccaneer BUCCANEER POWER. bulgin
bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
Magnetic proximity switches
Magnetic proximity switches Magnetic proximity switches Overview Page 38 Functional principle and installation Page 39 Cylindrical designs Page 41 Rectangular designs Page 42 37 Kurzübersicht Magnetoresistive
Optolite Indicators. General Purpose INDICATOR LIGHTS. Sub-Miniature. Miniature, Neon
Sub- Lockwasher, stainless steel or steel, nickel plate. Brass T-1 sub-midget flange base. See Selection Guide. Assembly mounts from front of panel. All mounting hardware Approximately.12 oz. less lamp.,
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions
Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of
Fakra. Coaxial connectors. DC 6 GHz
C-Blue D-Bordeaux GPS application GSM/Mobil Phone The FAKRA (Automobile Expert Group) has therefore defined a standardised connector system for the various communication applications in cars. Our FAKRA-compliant
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
mpm DIN 43650 CONNECTORS
mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide
HARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
Directory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
CONEC SnapLock. 1 Introduction
CONEC SnapLock E L E C T R O N I C C O N N E C T O R S 1 Introduction The new CONEC SnapLock locking system consists of D-SUB connectors and D-SUB hoods allowing quick and safe locking without any additional
Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option
REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration
Gas Mass Flow Control Products
Gas Mass Flow Control Products The Standard of Excellence in Mass Flow Porter Mass Flow products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement
400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics
SERIES HPQN CONNECTORS DESCRIPTION CONTENT Designed by James Qu at Anoison in 2006, the HPQN is a quick locking version of the widely used type N connector. By replacing the threaded interface of the original
Between Series Adapters
Between Series Adapters Between Series Coaxial Transmission Line Adapters provide convenient transitions between popular series coaxial connectors. The adapter design provides a minimum length consistent
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
SOURIAU s discrete wire sealing
SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
IEC Connectors. Introduction
Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
IP 20 B.1 8 IP 65 / IP 67 B.1 22. Cables B.1 96. Tools B.1 104 IP 20 B.2 8 IP 65 / IP 67 B.2 22. Cables B.2 90. Tools B.2 100 IP 20 B.
Ethernet cabling Contents Page B Ethernet cabling Ethernet cabling overview B 2 Profil-specific Cabling 4-wires B.1 8 B.1 22 Cables B.1 96 Tools B.1 104 Structured Cabling 8-wires B.2 8 B.2 22 Cables B.2
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
BIS M Industrial RFID System
13.56 MHz HF BIS M Industrial RFID System Inductive Identification The BIS M system uses a High Frequency or HF 13.56 MHz inductively coupled technology along with passive tags to provide mid-range RFID
RAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
Actuators and positioning drives
Actuators and positioning drives distributed by www.laumans.com Actuators and positioning drives FlexiDrive product range type MDBA 42 MSQA 46 MSAA 42 Actuator Actuator Actuator motor brush DC motor brush
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
Field bus connections Link structure CMS link structure CMS, B-design. Brochure
link structure CMS, B-design Brochure 2 link structure CMS, B-design Bus coupler with driver Optional field bus connection with I/O function (CMS), B-design Bus coupler with driver Field bus protocol:
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Connection technology from ifm.
Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
SPECIAL SPECIFICATION 1840 Convert Existing Traffic Management Equipment to ATM
1993 Specifications CSJ 0521-04-223 SPECIAL SPECIFICATION 1840 Convert Existing Traffic Management Equipment to ATM 1. Description. Convert existing Fiber Hubs, Communication Cabinets, Fiber Optic Variable
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
EXCELLENCE. LAPP SYSTEMS CAPABILITIES DESIGN AND FABRICATION OF POPULATED CABLE TRACK FULL ENGINEERING DESIGN AND DOCUMENTATION INCLUDING CAD DRAWINGS
EXPECT EXCELLENCE. With a heritage dating back to 1996, Lapp Systems USA was established with the merger of OLFLEX & Contact Electronics Systems groups. Today, with over 15 years of combined experience,
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)
PROXIMITY CARD READERS C-10, C-20, C60, C70
Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection
ETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist...
TABLE OF CONTENTS Custom Molded Cable Assemblies and Connectors..........................2 Capabilities.....................................................................3 Standard Connector Products.......................................................4
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
WORLD-BEAM QS30 Sensors
Datasheet High-Power Opposed-Mode Sensors Infared beam with high excess gain range of over 213 m (700 ft) Excellent noise immunity Excellent for applications ere high sensing power is required due to long
IBS IP I/O Gateway. Data Sheet INTERBUS-S. Coupling Module for Two InterBus-S Lines
IBS IP I/O Gateway Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 Main Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.stevenengineering.com Data Sheet
SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A
s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is