System Board D2619-N for PRIMERGY RX/TX300 S6
|
|
|
- Griffin Black
- 9 years ago
- Views:
Transcription
1 Technical Manual - English System Board D2619-N for PRIMERGY RX/TX300 S6 Technical Manual Edition March 2011
2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2010 Fujitsu Technology Solutions GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. No part of this manual may be reproduced in any form without the prior written permission of Fujitsu. Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.
3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety notes and other important information" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety notes and other important information" in a safe place for easy reference while using this product. Radio interference This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. As a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured for general uses such as general office use, personal use, domestic use and normal industrial use. It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. D2619-N (RX/TX300 S6) Technical Manual
4 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Harmonic Current Standards This product conforms to harmonic current standard JIS C Only for the Japanese market: About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: Technical Manual D2619-N (RX/TX300 S6)
5 Only for the Japanese market: I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: USB Flash Module (UFM) CSS (Customer Self Service) Replacing the lithium battery D2619-N (RX/TX300 S6) Technical Manual
6 Technical Manual D2619-N (RX/TX300 S6)
7 Contents 1 Introduction Notational conventions Important information Notes on safety CE certificate of conformity Environmental protection Features Overview Main memory Module population Types of memory modules Modes of operation PCI slots Screen resolution Temperature / system monitoring Connectors and indicators System board Connector panel Settings Jumper Switches Replacing the lithium battery D2619-N (RX/TX300 S6) Technical Manual
8 Contents Technical Manual D2619-N (RX/TX300 S6)
9 1 Introduction This technical manual describes the system board D2619-N, which can be equipped with up to two processors. For additional driver information (if available), refer to the Readme files located on the server hard disk and on the supplied DVDs (see Installation DVD of ServerView Suite - ServerView Software Products). You will find further information about the BIOS setup in the "D2619-N BIOS Setup Utility for PRIMERGY RX300 S6 and TX300 S6" manual. I PRIMERGY manuals are available in PDF format on the PRIMERGY ServerView Suite DVD 2. The PRIMERGY ServerView Suite DVD 2 is part of the PRIMERGY ServerView Suite supplied with every server. PRIMERGY Abbreviations and Glossary can also be found on the PRIMERGY ServerView Suite DVD Notational conventions The following notational conventions are used in this manual: Text in italics "Quotation marks" Ê V CAUTION! I indicates commands or menu items. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. D2619-N (RX/TX300 S6) Technical Manual 9
10 Notational conventions Introduction 10 Technical Manual D2619-N (RX/TX300 S6)
11 2 Important information In this chapter you will find essential information regarding safety when working with your server. V CAUTION! With the system board installed you must open the system to access the system board. How to access the system board of your system is described in the appropriate service supplement (except for the Japanese market). When handling the system board, refer to the specific notes on safety in the operating manual and/or service supplement for the respective server. 2.1 Notes on safety V CAUTION! The actions described in these instructions should only be performed by authorized, qualified personnel. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual, and any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability. Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts. Only install expansions that are allowed for the system board. If you install other expansions, you may damage the requirements and rules governing safety and electromagnetic compatibility or your system. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. D2619-N (RX/TX300 S6) Technical Manual 11
12 Notes on safety Important information V CAUTION! Components can become very hot during operation. Ensure you do not touch components when making extensions to the system board. There is a danger of burns! Transmission lines to peripheral devices must be adequately shielded. Ethernet cabling has to comply with EN and EN /2 standards or ISO/IEC standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or Category 5e for Gigabit Ethernet. Batteries V CAUTION! Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (this information doesn t apply to the Japanese market). It is essential to observe the instructions in the chapter "Replacing the lithium battery". 12 Technical Manual D2619-N (RX/TX300 S6)
13 Important information Notes on safety Modules with Electrostatic-Sensitive Devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When you handle components fitted with ESDs, you must always observe the following points: Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs. You must always discharge static build-up (e.g. by touching a grounded object) before working with such components. Any devices or tools that are used must be free of electrostatic charge. Wear a suitable grounding cable that connects you to the external chassis of the system unit. Always hold components with ESDs at the edges or at the points marked green (touch points). Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN , ANSI/ESD S20.20). D2619-N (RX/TX300 S6) Technical Manual 13
14 CE certificate of conformity Important information Notes about boards During installation/deinstallation of the board, observe the specific instructions described in the service supplement for the respective server. Shut down the server and disconnect the power plug, before you make modifications on an installed board. To prevent damage to the board, the components and conductors on it, please take great care when you insert or remove boards. Take great care to ensure that extension boards are slotted in straight, without damaging components or conductors on the board, or any other components, for example EMI spring contacts. Be careful with the locking mechanisms (catches, centring pins etc.) when you replace the system board or components on it, for example memory modules or processors. Never use sharp objects (screw drivers) for leverage. Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. 2.2 CE certificate of conformity The board complies with the requirements of the EC directives 2004/108/EC regarding Electromagnetic Compatibility and 2006/95/EC Low Voltage Directive. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. 14 Technical Manual D2619-N (RX/TX300 S6)
15 Important information Environmental protection 2.3 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Further information can be found at: (for the EMEA market) (for the Japanese market) Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information This packaging information doesn t apply to the Japanese market. Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. D2619-N (RX/TX300 S6) Technical Manual 15
16 Environmental protection Important information All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. Returns, recycling and disposal Please handle returns, recycling and disposal in accordance with local regulations. The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EC on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D Paderborn Tel Fax Technical Manual D2619-N (RX/TX300 S6)
17 3 Features I Not all features of the system board might be used in your server system. 3.1 Overview Processors 1 or 2 Intel Xeon processors of the 5500 or 5600 series 2 processor sockets LGA1366 for Intel Xeon processors integrated memory controller 32 KB L1 cache (on-die, data per core) 32 KB L1 cache (on-die, instruction per core) 256 KB second level cache per core up to 12 MB onchip shared third level cache 2 Intel QuickPath Interconnect with up to 6.4 GT/s in each direction 2x VRM 11.1 onboard (EVRD) Main memory up to 2x 9 slots for main memory, the number of allowed memory modules is dependent on memory type supports DDR3 800 / 1066 / 1333 UDIMM memory modules supports DDR3 800 / 1066 / 1333 RDIMM memory modules supports DDR / 1333 LV-UDIMM memory modules supports DDR / 1333 LV-RDIMM memory modules maximum 192 GB of memory minimum 1 GB maximum 32 Gbit/s band width (DDR3) up to 3 dual rank or 2 quad rank RDIMM memory rows per channel up to 2 UDIMM memory rows per channel ECC multiple-bit error detection and single-bit error correction memory scrubbing functionality Single Device Data Correction (SDDC) function (Chipkill ) Mirroring Sparing D2619-N (RX/TX300 S6) Technical Manual 17
18 Overview Features Chips on the system board Intel 5520 chip set Intel ICH10 Base (Intel 82801JIB) Intel dual-port Gigabit Ethernet controller Intel 82575EB 2 MB SPI flash (BIOS / iscsi, PXE Bootcode) Server Management controller irmc S2 with integrated graphic controller 16 MB SPI flash (code) for irmc S2 1 MB SPI flash (data) for irmc S2 32Mx DDR2 SRAM for irmc S2 SMSC8700 Fast Ethernet ADT7462 temperature/system monitoring controller Graphic integrated VGA controller with PCIe x1 interface (Matrox G200) 8 MB graphic memory available via driver VESA compatible LAN Ethernet controller 1x Intel 82575EB dual-port 10/100/1000 Mbit/s Base-T Ethernet controller PXE 2.1 and iscsi boot support IPV6 header offloading Storage devices 2x SATA2 (3 Gbit/s) 2x USB 2.0 (internal USB backup drives) 1x internal USB 2.0 memory stick Internal connectors 2x serial ATA connectors 1x operating panel connector 1x video connector (VGA) at the front side 1x internal USB stick connector 1x USB connector for 3 USB connectors at the front side 2x USB connectors for USB tape drives 1x connector for USB Flash Module (optional) 1x connector for Trusted Platform Module (optional) 1x power connector (12 V and 5 V auxiliary) 1x combined connector for HDD power supply and fan 18 Technical Manual D2619-N (RX/TX300 S6)
19 Features Overview 2x power connectors 1x connector for HDD activity LED 1x intrusion connector (only used for TX300 S6) External connectors 2x serial connectors (COM) 4x USB 2.0 connectors with 480 Mbit/s at the rear side 1x video connector (VGA) 2x RJ45 LAN connectors 1x RJ45 service LAN connector PCI slots 2x PCI-Express 2.0 x8 slots 1x PCI-Express 2.0 x4 slot 4x PCI-Express 2.0 x4 slots, can be alternatively configured as four x4 slots or two x8 slots (if the neighbour slot isn t equipped) Server Management controller irmc S2 basic functionalities: fan control, voltage supervision for onboard voltages, temperature monitoring, System Event Log and ASR&R (Automatic Server Reconfiguration and Restart) PDA Global Error/CSS/ID LED HD LED support (SAS, SATA) Inventory Identification Control pre-failure warranty for memory CSS functionality power consumption control text console redirection Advanced Video Redirection - AVR remote storage Security features Supervisor and User password recovery BIOS support flash write protection against virus D2619-N (RX/TX300 S6) Technical Manual 19
20 Overview Features Power management ACPI (states S0, S1, S5) 3.3 V standby power on the PCI Express slots on/off/sleep/wake by power button on/off by software wake on by RTC, external serial ports, LAN, PCI Express controller and irmc S2 power on by power button, external serial ports, LAN, PCI Express controller and irmc S2 BIOS features Phoenix SecureCore SMBIOS 2.5 (DMI) MultiProcessor specification Server Hardware Design Guide WfM ACPI support LSI SAS/RAID BIOS USB keyboard/mouse boot possible from: hard disk (SATA, SAS, SCSI, USB) USB stick CD/DVD (IDE, SATA, SAS) LAN console redirection support OEM logo CPU, memory disable Mirroring and Spare memory support Environmental protection Battery in holder for recycling Form factor, slot compatibility list 415 x 417mm ACPI 2.0, OnNow, PCI Express 2.0, LPC 1.1, WfM 2.0, SHDG 3.0, MPS 1.4, IPMI 2.0, PCI SHPC 1.0 and PCI Express card electromechanical specification rev. 1.0, USB2.0, SATA Technical Manual D2619-N (RX/TX300 S6)
21 Features Overview CSS (Customer Self Service) This system board supports the CSS functionality. You will find a description of CSS functionality in the operating manual of your server. USB Flash Module (option) The system board can be equipped with an USB Flash Module (UFM) by the manufacturer or by an add-on kit. The module can be used as optional memory for software (e.g. VMware) or as a software dongle. I The USB Flash Module can not be used together with an USB device in the internal USB stick connector. Internal USB stick (option) The system board can be equipped with an internal USB stick by the manufacturer. I The internal USB stick can not be used together with an installed UFM. TPM (option) The system board can be equipped with a TPM (Trusted Platform Module) by the manufacturer or by an add-on kit. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the BIOS manual). V CAUTION! When using the TPM, note the program descriptions provided by the third party manufacturers. You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data. If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. D2619-N (RX/TX300 S6) Technical Manual 21
22 Main memory Features 3.2 Main memory The system board supports up to 192 GB main memory. 18 slots for main memory are available. Each slot can be populated with 1 GB, 2 GB single or dual rank UDIMM or 1 GB, 2 GB, 4 GB, 8 GB, 16 GB single, dual or quad rank RDIMM memory modules. Besides low-voltage DIMMs are supported. The minimum population in the Independent Channel Mode is one DIMM. ECC with memory scrubbing and with the Single Device Data Correction (SDDC) function is supported. I You will find the descriptions how to install memory modules in the Options Guide of your server Module population Channel F Channel E Channel D Channel A Channel B Channel C DIMM 1F DIMM 2F DIMM 3F DIMM 1E DIMM 2E DIMM 3E DIMM-1D 1D DIMM 2D DIMM 3D CPU 2 CPU 1 DIMM 3A DIMM 2A DIMM 1A DIMM 3B DIMM 2B DIMM 1B DIMM 3C DIMM 2C DIMM 1C Figure 2: Assembly of the main memory in channels and slots The arrows in figure 2 show the direction of the population of the memory slots. The memory modules are organized in 6 channels (A - F). Each channel has three slots (1-3). The channels A - C are controlled by CPU 1 and the channels D - F are controlled by CPU Technical Manual D2619-N (RX/TX300 S6)
23 Features Main memory Types of memory modules RDIMM memory modules Technology: DDR3 800 / 1066 / 1333 buffered single rank (SR), dual rank (DR) or quad rank (QR) RDIMM memory modules with ECC. LV-RDIMM memory modules Technology: DDR3 800 / 1066 / 1333 buffered single rank (SR), dual rank (DR) or quad rank (QR) LV-RDIMM memory modules with ECC. LV-RDIMM memory modules are not supported by Intel Xeon processors of the 5500 series. UDIMM memory modules Technology: DDR3 800 / 1066 / 1333 unbuffered single rank (SR) or dual rank (DR) UDIMM memory modules with ECC. LV-UDIMM memory modules Technology: DDR3 800 / 1066 / 1333 unbuffered single rank (SR) or dual rank (DR) LV-UDIMM memory modules with ECC. LV-UDIMM memory modules are not supported by Intel Xeon processors of the 5500 series. D2619-N (RX/TX300 S6) Technical Manual 23
24 Main memory Features Restrictions The following configurations are not supported: 2DPC QRRDIMMs at DDR speed or above 1DPC QRRDIMM at DDR speed or above 3DPC SR/DR RDIMMs at DDR speed or above Mixing QR RDIMMs on one channel and 3DPC SR/DR RDIMMs on another channel on same CPU socket Mixing RDIMMs and UDIMMs anywhere on same system Any DIMMs using 256 Mbit, 512 Mbit or 4Gbit DRAM technologies x16dram on RDIMM or x4dram on UDIMM and QR UDIMM If 1.35 V (DDR3L) and 1.50 V (DDR3) DIMMs are mixed, the DIMMs will run at 1.50 V. DIMMs with different timing parameters can be installed on different slots within the same channel, but only timings that support the slowest DIMM will be applied to all. As a consequence, faster DIMMs will be operated at timings supported by the slowest DIMM populated. The same interface frequency (DDR3-800, DDR3-1066, or DDR3-1333) will be applied to all DIMMs on all channels on the platform (both processors). If one quad rank DIMM is used, it must be populated in DIMM slot 0 (farthest away from the CPU) of a given channel. I For system relevant information please refer to the configurator of the server: or (for the EMEA market) (for the Japanese market) 24 Technical Manual D2619-N (RX/TX300 S6)
25 Features Main memory Modes of operation There are three modes of operation for the main memory: Independent Channel Mode (maxium population) / Performance Mode (recommended) The populated memory of the six channels (A - F) can be used completely. Mirrored Channel Mode (maximum security) Only the populated memory of the two channels A and D can be used. The channels B and E serve as safeguarding against failure. The memory belonging to the channels B and E contain the mirrored data of the memory belonging to channel A and D. The channels C and F are not used. Spare Channel Mode (large population and large security) Only the populated memory of the four channels A, B, D and E can be used. The channels C and F serve as safeguarding against failure. Depending on the mode of operation there are different population requirements for the main memory. I For system relevant information please refer to the configurator of the server: or (for the EMEA market) (for the Japanese market) D2619-N (RX/TX300 S6) Technical Manual 25
26 PCI slots Features 3.3 PCI slots The system board offers seven PCI-Express slots. The slots 1-5 are wired as x4 interfaces. If the slots 2 and 4 remain empty, the slots 3 and 5 can be used as x8 interfaces. I Slot 1 is the preferred slot for the HDD controller (bootable). Slot 7 PCIe x8 Slot 6 PCIe Slot 5 PCIe x8 x4 x8 CPU 2 Slot 4 PCIe Slot 3 PCIe Slot 2 PCIe Slot 1 PCIe x4 x4 x4 x4 empty x8 empty CPU 2 DIMM 3D CPU 2 DIMM 2D CPU 2 DIMM 1D CPU 2 DIMM 3E CPU 2 DIMM 2E CPU 2 DIMM 1E CPU 2 DIMM 3F CPU 2 DIMM 2F CPU 2 DIMM 1F Figure 3: PCIe slots The following table shows an overview of the PCIe slots: PCI slot Description 1 PCIe x4 slot for RAID controller 2 PCIe x4 slot 3 PCIe x4 slot (if slot 2 empty: x8) 4 PCIe x4 slot 5 PCIe x4 slot (if slot 4 empty: x8) 6 PCIe x8 slot 7 PCIe x8 slot 26 Technical Manual D2619-N (RX/TX300 S6)
27 Features Screen resolution 3.4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the graphic controller on the system board. The graphic controller is integrated in the irmc S2 (integrated Remote Management Controller). Screen resolution (pixel) Maximum refresh rate (Hz) 640x bit 800x bit 1024x bit 1152x bit 1280x bit 1600x bit Max. number of colours If you are using an external graphic controller, you will find details of supported screen resolutions in the operating manual or technical manual supplied with the graphic controller. 3.5 Temperature / system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating. In addition, any unnecessary noise is also prevented by reducing the fan speed, and information is provided about the system status. The temperature and system monitoring are controlled by the irmc S2 (integrated Remote Management Controller). The following functions are supported: Temperature monitoring Measurement of the processor and the system internal temperature by an onboard temperature sensor, measurement of the ambient temperature by a I 2 C temperature sensor. D2619-N (RX/TX300 S6) Technical Manual 27
28 Temperature / system monitoring Features Fan monitoring The power supply unit and system fans are monitored. Fans that are no longer available, blocked or stuck fans are detected. Fan control The fans are regulated according to temperature. Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware. Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated. Cover monitoring (only TX300 S6) Unauthorized opening of the cover is detected, even when the system is switched off. However, this will only be indicated when the system is switched on again. System Event Log (SEL) All monitored events of the system board are signalized via the Global Error LED or CSS LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup, irmc S2 s Web interface or via the ServerView Operations Manager. PRIMERGY Local Diagnostic LEDs Optical signaling through the LEDs on the system board identifies defective modules and components (CSS functionality) as well as gaining information on the PDA (Prefailure Detection and Analysis). 28 Technical Manual D2619-N (RX/TX300 S6)
29 Features Connectors and indicators 3.6 Connectors and indicators System board external connectors Serial 1 Serial 2 VGA USB 3/4 USB 1/2 Service LAN LAN 2 LAN 1 Front VGA TPM Enable SM CTRL LAN CTRL Front Panel SATA1 TPM SATA2 Front USB USB Stick ussd USB INT 1 USB INT 2 Power Connector 2 Power Connector 1 CPU 1 DIMM 1C CPU 1 DIMM 2C CPU 1 DIMM 3C CPU 1 DIMM 1B CPU 1 DIMM 2B CPU 1 DIMM 3B CPU 1 DIMM 1A CPU 1 DIMM 2A CPU 1 DIMM 3A CPU 1 Slot 7 PCIe x8 Slot 6 PCIe Slot 5 PCIe x8 x4 x8 CPU 2 Slot 4 PCIe x4 empty Slot 3 PCIe x4 x8 Slot 2 PCIe x4 empty Battery Slot 1 PCIe x4 Intrusion HD LED DIP Switch Indicate CSS HDD Pwer/ FAN Control CPU 2 DIMM 3D CPU 2 DIMM 2D CPU 2 DIMM 1D CPU 2 DIMM 3E CPU 2 DIMM 2E CPU 2 DIMM 1E CPU 2 DIMM 3F CPU 2 DIMM 2F CPU 2 DIMM 1F Figure 4: Internal connectors of the system board D2619-N D2619-N (RX/TX300 S6) Technical Manual 29
30 Connectors and indicators Features No. Print Description 1 Front VGA Front VGA connector 2 Front Panel Front panel connector 3 TPM Connector for TPM 4 SATA 1 SATA1 connector 5 SATA 2 SATA2 connector 6 Front USB USB connector for USB on the front side 7 USB Stick USB stick connector 8 ussd Connector for USB Flash Module (UFM) 9 USB INT 1 Internal USB connector 1 10 USB INT 2 Internal USB connector 2 11 Power Connector 1 Power supply connector 1 12 Power Connector 2 Power supply connector 2 13 HDD Power/FAN Power supply connector for fans and HDDs Control 14 Intrusion Intrusion connector (only used for TX300 S6) 15 HD LED Connector for HDD activity LED 30 Technical Manual D2619-N (RX/TX300 S6)
31 Features Connectors and indicators A B C D E D E D E F external connectors VGA Serial 1 Serial 2 USB 3/4 USB 1/2 Service LAN LAN 2 LAN 1 SM CTRL LAN CTRL Slot 7 PCIe Slot 6 PCIe Slot 5 PCIe Slot 4 PCIe Slot 3 PCIe Slot 2 PCIe Slot 1 PCIe M x8 x8 x4 x4 x4 x4 x4 L DIP Switch Indicate CSS Figure 5: Indicators on the system board and CSS indicate button x8 x8 N empty empty O Battery K I H H G G CPU 1 DIMM 1C CPU 1 DIMM 2C CPU 1 DIMM 3C CPU 1 DIMM 1B CPU 1 DIMM 2B CPU 1 DIMM 3B CPU 1 DIMM 1A CPU 1 DIMM 2A CPU 1 DIMM 3A CPU 1 CPU 2 CPU 2 DIMM 3D CPU 2 DIMM 2D CPU 2 DIMM 1D CPU 2 DIMM 3E CPU 2 DIMM 2E CPU 2 DIMM 1E CPU 2 DIMM 3F CPU 2 DIMM 2F CPU 2 DIMM 1F No. Description 1 CSS indicate button LEDs A, B, C, D and E are visible from outside on the rear of the server. All the other LEDs are only visible, if the cover of the server has been opened. If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the CSS indicate button. D2619-N (RX/TX300 S6) Technical Manual 31
32 Connectors and indicators Features The LEDs have the following meaning: LED Indicator Meaning A - Identification blue on server is identified via the ServerView Operations Manager blue flashing local monitor off via AVR B - CSS off no error (CSS component) (Customer Self yellow on indicates a prefailure (CSS component) Service) yellow flashing indicates a failure (CSS component) C - GEL off no error (non CSS component) (Global Error orange on indicates a prefailure (non CSS LED) component) orange flashing indicates a failure of a non CSS component. Reasons for a failure may be: - over temperature measured by one of the sensors - sensor is defective - CPU error - software detected an error D - LAN link/ Indicator and meaning see "LAN connectors" on page 34. transfer E - LAN speed Indicator and meaning see "LAN connectors" on page 34. F - PCI card off PCI card okay orange on PCI card failure G - CPU off CPU okay orange on CPU failure H - memory off memory module running orange on memory module failure I - PS CTRL ok green on Power supply controller okay K - PS CTRL orange on Power supply controller error error L - main power green on main power okay 32 Technical Manual D2619-N (RX/TX300 S6)
33 Features Connectors and indicators LED Indicator Meaning M - standby yellow on all standby voltages are okay power N - board error red on system board is faulty O - irmc green flashing irmc S2 is okay Connector panel Figure 6: Connector panel No. Description 1 ID indicator (blue) 2 CSS indicator (yellow) 3 Global error indicator (orange) 4 Serial connector COM2 5 Serial connector COM1 6 Video connector (VGA) 7 USB connectors 8 Service LAN connector, for irmc S2 server management function 9 System LAN connector (LAN 2) 10 System LAN connector (LAN 1) The serial connector COM1 can be used as default interface or to communicate with the irmc S2. D2619-N (RX/TX300 S6) Technical Manual 33
34 Connectors and indicators Features LAN connectors The system board is equipped with an Intel dual-port Gigabit Ethernet controller (Intel 82575EB). The LAN controller supports transmission rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller also supports WOL functionality by means of Magic Packet. It is also possible to start a system via a LAN without a separate boot hard disk drive. PXE is supported here. The separate service LAN connector is used as a management interface (irmc S2) and is prepared for operation with the Remote Management. Each LAN connector has two LEDs which display the speed of the connection and its status: Figure 7: LAN LEDs No Indicator Description 1 LAN link/transfer (service LAN) Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. 2 LAN speed (service LAN) 3 LAN link/transfer (system LAN) Steady green signal in the event of a LAN transfer rate of 100 Mbit/s. Remains dark in the event of a LAN transfer rate of 10 Mbit/s. Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. 34 Technical Manual D2619-N (RX/TX300 S6)
35 Features Connectors and indicators No Indicator Description 4 LAN speed (system LAN) Steady yellow signal in the event of a LAN transfer rate of 1 Gbit/s Steady green signal in the event of a LAN transfer rate of 100 Mbit/s. Remains dark in the event of a LAN transfer rate of 10 Mbit/s. D2619-N (RX/TX300 S6) Technical Manual 35
36 Settings Features 3.7 Settings Jumper Jumper TPM Enable external connectors Serial 1 Serial 2 VGA Front VGA TPM Enable SM CTRL Front Panel TPM SATA1 SATA2 Front USB USB Stick ussd USB INT 1 USB INT 2 Power Connector 1 CPU 1 DIMM 1C CPU 1 DIMM 2C CPU 1 DIMM 3C CPU 1 DIMM 1B CPU 1 DIMM 2B CPU 1 DIMM 3B CPU 1 DIMM 1A CPU 1 DIMM 2A CPU 1 DIMM 3A Figure 8: Position of the jumper TPM Enable I Default setting: pins 1 and 2 are connected. Without this setting the TPM function is disabled. Default Pin Signal Description 1 TPM_RESET_L Reset of the TPM 2 ICH_TMP_DIS_L Reset of the ICH10 36 Technical Manual D2619-N (RX/TX300 S6)
37 Features Settings Switches DIP switches Slot 3 PCIe x4 x8 Slot 2 PCIe x4 empty Battery Slot 1 PCIe x4 Intrusion HD LED DIP Switch Indicate CSS HDD Pwer/ FAN Control CPU 2 DIMM 3D CPU 2 DIMM 2D CPU 2 DIMM 1D CPU 2 DIMM 3E CPU 2 DIMM 2E CPU 2 DIMM 1E CPU 2 DIMM 3F CPU 2 DIMM 2F CPU 2 DIMM 1F Figure 9: Position of the DIP switches I Default setting: switches 1 to 4 are set to Off. Default Switch Function Status Description S1-1 Recovery On Boot block enabled BIOS Off Normal boot S1-2 Password skip On Password skip enabled Off Password skip disabled S1-3 BIOS flash On BIOS can only be read write-protect Off BIOS can both be read and written to S1-4 Not used I Recovery BIOS Switch 1 enables recovery of the old system BIOS after an attempt to update has failed. To restore the old system BIOS you need a Flash BIOS medium (see the BIOS manual or please call our customer service centre). Password skip Switch 2 is used to define whether the password is skipped at system startup, if the password protection is enabled in the BIOS Setup (in Security menu, the Password on boot field must be set to Enabled). D2619-N (RX/TX300 S6) Technical Manual 37
38 Settings Features 38 Technical Manual D2619-N (RX/TX300 S6)
39 4 Replacing the lithium battery In order to save the system information permanently, a lithium battery is installed to provide the CMOS-memory with a current. When the charge is too low or the battery is empty, a corresponding error message is provided. The lithium battery must then be replaced. V The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer (CR2450). This information doesn t apply to the Japanese market. Do not throw lithium batteries into the trash can. It must be disposed of in accordance with local regulations concerning special waste. Make sure that you insert the battery the right way round. The plus pole must be on the top! Figure 10: Replacing the lithium battery Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). D2619-N (RX/TX300 S6) Technical Manual 39
40 Replacing the lithium battery 40 Technical Manual D2619-N (RX/TX300 S6)
System Board D2863 for PRIMERGY RX100 S6
Technical Manual - English System Board D2863 for PRIMERGY RX100 S6 Technical Manual Edition February 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
System Board D3009 for PRIMERGY TX100 S3
Technical Manual - English System Board D3009 for PRIMERGY TX100 S3 Technical Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
System Board D2779 for PRIMERGY TX100 S2
Technical Manual - English System Board D2779 for PRIMERGY TX100 S2 Technical Manual Edition June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
PRIMERGY BX620 S6 Server Blade
Options Guide - English PRIMERGY BX620 S6 Server Blade Options Guide August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your
System Board D2559 for TX150 S6. Technical Manual
System Board D2559 for TX150 S6 Technical Manual Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
Fujitsu PRIMERGY BX920 S2 Dual-Socket Server
Datasheet Fujitsu PRIMERGY BX920 S2 Dual-Socket Server Blade Datasheet for Red Hat certification Universal Dual-Sockel Server Blade with high computing and I/O performance in a small form factor The PRIMERGY
PRIMERGY TX100 S1. Options Guide
PRIMERGY TX100 S1 Options Guide Edition August 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)
User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Edition February 2013 Comments Suggestions Corrections The User Documentation Department would like
TS500-E5. Configuration Guide
TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may
Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade
Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal
Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500
Pages: Data Sheet The wide-ranging home office and multimedia PC Issue: November 2009 The wide-ranging is the ideal home office and multimedia PC for families. Equipped with powerful Intel processor and
Fujitsu PRIMERGY BX924 S2 Dual-Socket server
Datasheet Fujitsu PRIMERGY BX924 S2 Dual-Socket server blade Datasheet for Red Hat certification Server Blade with virtualization fitness at all levels, be it compute power or I/O throughput The PRIMERGY
Chapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
Tipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2
Tipos de Máquinas X550M2 1. Overview - 7946 x3550 M2 IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized,
Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000
Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000 Datasheet for Red Hat certification PRIMERGY CX1000 is a new product category within the PRIMERGY x86 server family. Its focus
DD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
PRIMERGY Econel 50 Server System
PRIMERGY PRIMERGY Econel 50 Server System Service Supplement Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001-157 Fax: 0 700
Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server
Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Enter the world of PRIMERGY TX servers FUJITSU Server PRIMERGY systems provide the most
Options Guide - English PRIMERGY TX100 S2. Options Guide
Options Guide - English PRIMERGY TX100 S2 Options Guide July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
FUJITSU Server PRIMERGY RX100 S8
Operating Manual - English FUJITSU Server PRIMERGY RX100 S8 Operating Manual Edition November 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of
Intel Desktop Board D925XECV2 Specification Update
Intel Desktop Board D925XECV2 Specification Update Release Date: July 2006 Order Number: C94210-005US The Intel Desktop Board D925XECV2 may contain design defects or errors known as errata, which may cause
Data Sheet Fujitsu Server PRIMERGY TX1320 M1 Tower Server
Data Sheet Fujitsu Server PRIMERGY TX1320 M1 Tower Server Data Sheet Fujitsu Server PRIMERGY TX1320 M1 Tower Server For small environments with high demands FUJITSU Server PRIMERGY systems provide the
H97M-E/CSM. Chipset. Memory. Graphic. Expansion Slots. Storage
H97M-E/CSM Intel Socket 1150 for the 5 th /New 4 th /4 th Generation Core i7/core i5/core i3/pentium /Celeron Processors Supports Intel 22 nm CPU Supports Intel Turbo Boost Technology 2.0 * The Intel Turbo
FUJITSU Server PRIMERGY RX1330 M2
Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to
EVGA Z97 Classified Specs and Initial Installation (Part 1)
User Guide EVGA Z97 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and
Manual OS Installation
CA92276-8158 EN-09 ECONEL 100 S2 / TX120 / TX150 S6 / TX300 S4 / RX100 S5 / RX200 S4 / RX300 S4 / RX600 S4 Manual OS Installation Before Reading This Manual Before Reading This Manual Remarks Symbols Symbols
PRIMERGY RX300 S6 Server
Service Supplement - english PRIMERGY RX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
Data Sheet Fujitsu PRIMERGY BX922 S2 Dual-Socket Server Blade
Data Sheet Fujitsu PRIMERGY BX922 S2 Dual-Socket Server Blade Future-oriented Server Blade with all the prerequisites for virtualization environments The PRIMERGY BX Blade Servers are the ideal choice
v1 System Requirements 7/11/07
v1 System Requirements 7/11/07 Core System Core-001: Windows Home Server must not exceed specified sound pressure level Overall Sound Pressure level (noise emissions) must not exceed 33 db (A) SPL at ambient
HP ProLiant DL165 G7 Server. Installation Instructions
HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status
Manual IB-3620 Series
IB-RD3620SU3 1 IB-3620U3 CONTENT 1. Introduction... 3 1.1 General Information... 3 2. Hardware IB-3620 Series... 4 2.1 LED Indication / Button Front Panel... 4 2.2 Rear View... 5 3. HDD Installation...
PRIMERGY CX400 S2 Server Enclosure
Upgrade and Maintenance Manual - English PRIMERGY CX400 S2 Server Enclosure Upgrade and Maintenance Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would
Data Sheet Fujitsu PRIMERGY TX140 S1 Mono-Socket Intel Xeon processor server
Data Sheet Fujitsu PRIMERGY TX140 S1 Mono-Socket Intel Xeon processor server Expandable SME All-Round Server PRIMERGY TX industry standard tower servers: efficient, rock solid, record-breaking performance.
System Configuration and Order-information Guide ECONEL 100 S2. March 2009
System Configuration and Orderinformation Guide ECONEL 100 S2 March 2009 Front View DVDROM Drive 5 inch Bay Floppy Disk Drive Back View Mouse Keyboard Serial Port Display 10/100/1000BASET Connector Inside
Data Sheet FUJITSU Server PRIMERGY RX1330 M1 rack server
Data Sheet FUJITSU Server PRIMERGY RX1330 M1 rack server Data Sheet FUJITSU Server PRIMERGY RX1330 M1 rack server Small in size and low in cost rich in optional features FUJITSU Server PRIMERGY systems
PRIMERGY RX200 S7 Server
Operating Manual - English PRIMERGY RX200 S7 Server Operating Manual Edition April 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
Datasheet Fujitsu PRIMERGY RX100 S6 Mono Socket Intel Xeon Rack Server (1U)
Datasheet Fujitsu PRIMERGY RX100 S6 Mono Socket Intel Xeon Rack Server (1U) Cost optimized and highly modular multi usage rack server The PRIMERGY RX Rack Server family is the perfect platform to form
Upgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
Data Sheet FUJITSU Server PRIMERGY BX920 S4 Dual Socket Server Blade
Data Sheet FUJITSU Server PRIMERGY BX920 S4 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX920 S4 Dual Socket Server Blade Mainstream dual-socket server blade for essential enterprise workloads
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster
Fujitsu PRIMERGY BX600 S3 Blade Server
Datasheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem - the ideal platform for branch offices and medium-sized companies The PRIMERGY BX Blade Servers are the ideal choice for the data
Areas Covered. PRIMERGY BX620 S4 Server Blade User s Guide
PRIMERGY BX620 S4 Server Blade User s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read this section.
IBM Europe Announcement ZG08-0232, dated March 11, 2008
IBM Europe Announcement ZG08-0232, dated March 11, 2008 IBM System x3450 servers feature fast Intel Xeon 2.80 GHz/1600 MHz, 3.0 GHz/1600 MHz, both with 12 MB L2, and 3.4 GHz/1600 MHz, with 6 MB L2 processors,
How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X
System Configuration and Order-information Guide RX00 S4 February 008 Front View CD-ROM Drive (Optional) Hard Disk Bay Back View PCI Slot 0/00/000BASE-T connector Serial Port Display Mouse Keyboard Inside
Data Sheet Fujitsu PRIMERGY TX120 S3p Server
Data Sheet Fujitsu PRIMERGY TX120 S3p Server For small environments with high demands PRIMERGY TX tower servers are ideal for use in SMEs or branch offices. They increase operational efficiency by providing
Computer Setup User Guide
Computer Setup User Guide Copyright 2008 Hewlett-Packard Development Company, L.P. Bluetooth is a trademark owned by its proprietor and used by Hewlett-Packard Company under license. Intel is a trademark
Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor
Servers, Clients Displaying max. 60 cameras at the same time Recording max. 80 cameras Desktop or rackmount form factor IVR-40/40-DSKT Intellio standard server PC 60 60 Recording 60 cameras Video gateway
Optimized dual-use server and high-end workstation performance
Optimized dual-use server and high-end workstation performance The ATX-sized(EEB mounting hole locations) Z9PA-U8 supports the latest Intel Xeon processor E5-2600 and E5-1600 product family, featuring
Getting Started. Chapter 1
Chapter 1 Getting Started Thank you for choosing the 7728 v2.x Series Micro-ATX mainboard. The 7728 v2.x Series mainboards are based on Intel H61 chipsets for optimal system efficiency. Designed to fit
Data Sheet FUJITSU Server PRIMERGY RX200 S8 Dual socket 1U rack server
Data Sheet FUJITSU Server PRIMERGY RX200 S8 Dual socket 1U rack server Data Sheet FUJITSU Server PRIMERGY RX200 S8 Dual socket 1U rack server Maximum productivity in a 1U housing The PRIMERGY RX Rack Server
Data Sheet Fujitsu ESPRIMO P2440 Desktop PC
Data Sheet Fujitsu ESPRIMO P2440 Desktop PC Your immediately available Office PC ESPRIMO P2440 Equipped with proven AMD technology the ESPRIMO P2440 is the best choice for cost-conscious buyers in small
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
Technical Information Jumpers, Connectors and Memory JXM7031 (7031-xxx) MicroATX Motherboard Dual Jasper Forest Processors
Technical Information Jumpers, Connectors and Memory JXM7031 (7031-xxx) MicroATX Motherboard Dual Jasper Forest Processors Dimension Diagram * = Pin 1 = Card Slots are on.800 centers Notes: All dimensions
PRIMERGY RX600 S6 Server
Operating Manual - English PRIMERGY RX600 S6 Server Operating Manual July 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback
Data Sheet Fujitsu Server PRIMERGY TX140 S2 Mono-Socket Intel Xeon processor server
Data Sheet Fujitsu Server PRIMERGY TX140 S2 Mono-Socket Intel Xeon processor server Expandable all-round server for SMEs Fujitsu Server PRIMERGY TX Tower Servers are ideal for use in SMEs or branch offices.
Data Sheet Fujitsu PRIMERGY TX140 S1p Mono-Socket Intel Xeon processor server
Data Sheet Fujitsu PRIMERGY TX140 S1p Mono-Socket Intel Xeon processor server Expandable SME all-round server PRIMERGY TX tower servers are ideal for use in SMEs or branch offices. They increase operational
Data Sheet Fujitsu Server PRIMERGY TX1320 M1 Tower Server
Data Sheet Fujitsu Server PRIMERGY TX1320 M1 Tower Server Data Sheet Fujitsu Server PRIMERGY TX1320 M1 Tower Server For small environments with high demands FUJITSU Server PRIMERGY systems provide the
Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server
Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server Enter the world of PRIMERGY TX servers Fujitsu Server PRIMERGY TX Tower Servers are ideal for use in SMEs or branch offices. They increase operational
Infinity C Reference Guide
1 2! Infinity C Reference Guide Table of Contents Components... 1 Hardware Setup... 5 SmartDrive Configuration... 12 Startup... 15 Login... 16 System Configuration... 19 DICOM Setup... 20 Monitoring Status...
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing
Home Theater PC Chassis
Home Theater PC Chassis Model: HTPC 180 BA & SA Color: Black & Silver Quick Installation Guide (U.S. & Canada Only) Version 1.0 DISCLAIMER No warranty or representation, either expressed or implied, is
High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis
High Performance 2U Storage Server Based on the Intel Socket R E5-2600 processor platform, the ASUS RS720-E7/RS12 server offers customers an extensive feature set: mass storage. high memory capacity, outstanding
HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide
HP SuperSpeed USB 3.0 PCIe x1 Card User Guide Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
HP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server The Dynamic Cube Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well as the branches and data centers of large
Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server
Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server Advanced Blade Ecosystem the ideal platform for branch offices and mediumsized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
DCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
How To Run A Server On A Powerbook From A Microsoft Powerbook (Powerbook) On A Mini Mini Mini Server (Powerbox) On An X86 Or Microsoft Mini Server
Data Sheet FUJITSU Server PRIMERGY RX100 S7p Mono socket 1U rack server Small in size and low in cost rich in optional features The Fujitsu Server PRIMERGY RX Rack Server family is the perfect platform
HQP-1072 Series System User Guide
HQP-1072 Series System User Guide Table of Contents HQP-1072 Hardware User Guide...3 1. HQP-1072 system Introduction...4 1.1 Box Contents...4 1.2 Specification...6 1.3 Appearance...8 2. Setting Up...10
Data Sheet ESPRIMO P3510. Your flexible economic PC ESPRIMO P3510
Pages: Data Sheet Your flexible economic PC Issue: September 2009 The is the right choice for major customers requiring the latest standard features. This Microtower PC is the ultimate balance between
Getting Started. rp5800, rp5700 and rp3000 Models
Getting Started rp5800, rp5700 and rp3000 Models Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
McAfee Firewall Enterprise
Hardware Guide Revision C McAfee Firewall Enterprise S1104, S2008, S3008 The McAfee Firewall Enterprise Hardware Product Guide describes the features and capabilities of appliance models S1104, S2008,
EVGA X99 Classified Specs and Initial Installation (Part 1)
User Guide EVGA X99 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and
Z97-PRO GAMER Especificaciones
Z97-PRO GAMER Especificaciones CPU Intel Socket 1150 for the 5 th /New 4 th /4 th Generation Core i7/core i5/core i3/pentium /Celeron Processors Supports Intel 22 nm CPU Supports Intel Turbo Boost Technology
Data Sheet Fujitsu Server PRIMERGY BX924 S4 Dual Socket Server Blade
Data Sheet Fujitsu Server PRIMERGY BX924 S4 Dual Socket Server Blade Datasheet for Red Hat certification High-end server blade with maximum scalability for demanding applications FUJITSU Server PRIMERGY
Data Sheet Fujitsu PRIMERGY TX200 S6 Server
Data Sheet Fujitsu PRIMERGY TX200 S6 Server Well-balanced price- performance PRIMERGY TX industry standard tower servers: efficient, rock solid, record-breaking performance. PRIMERGY TX servers benefit
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DH55TC, DH55HC, DH55PJ (Standard BIOS) BIOS Version 0040 - TCIBX10H.86A.0040.2010.1018.1100 October 18, 2010 Integrated Graphics Option ROM Revision on HC/TC: 2017 PC
Executive Series. Intel Desktop Board DB75EN Executive Series MicroATX Form Factor
Intel Desktop Board DB75EN MicroATX Form Factor product brief Built for Business: Intel Desktop Board DB75EN maximizes employee productivity, PC performance, and data security with Intel Small Business
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DH61BE, DH61CR, DH61DL, DH61WW, DH61SA, DH61ZE (Standard BIOS) BIOS Version 0120 - BEH6110H.86A.0120.2013.1112.1412 Date: November 12, 2013 ME Firmware: Ignition SKU
SATA PCI Express Adapter PEXSATA22I
SATA PCI Express Adapter PEXSATA22I FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description
INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone
Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I
Highly Scalable Server for Many Possible Uses MAXDATA PLATINUM Server 3200 I MAXDATA PLATINUM Server 3200 I: Highly Scalable Server for Many Possible Uses Standard Features Now more than ever, profitable
Monthly Specification Update
Intel Server Board S1200BTLR Intel Server Board S1200BTSR Intel Server Board S1200BTLRM Intel Server System R1304BTLSFANR Intel Server System R1304BTSSFANR Intel Server System R1304BTLSHBNR Intel Server
Data Sheet Fujitsu Server PRIMERGY TX1320 M2 Tower Server
Data Sheet Fujitsu Server PRIMERGY TX1320 M2 Tower Server Data Sheet Fujitsu Server PRIMERGY TX1320 M2 Tower Server For small environments with high demands FUJITSU Server PRIMERGY will give you the servers
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.
Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces
FUJITSU Server PRIMERGY CX2550 M2 Server Node
Operating Manual - English FUJITSU Server PRIMERGY CX2550 M2 Server Node Operating Manual Edition November 2015 Comments Suggestions Corrections The User Documentation Department would like to know your
Cisco MCS 7825-H3 Unified Communications Manager Appliance
Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
DIVAR IP 2000 DIP-2040-00N, DIP-2042-2HD, DIP-2042-4HD. en Installation Manual
DIVAR IP 2000 DIP-2040-00N, DIP-2042-2HD, DIP-2042-4HD en Installation Manual DIVAR IP 2000 Table of Contents en 3 Table of contents 1 Safety precautions 4 1.1 General safety precautions 4 1.2 Electrical
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
Cisco MCS 7816-I3 Unified Communications Manager Appliance
Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
System x3650 Type 7979
System x3650 Type 7979 User s Guide Table 1. Features and specifications Microprocessor: v Intel Xeon FC-LGA 771 dual-core with 4 MB Level-2 cache or quad-core with 8 MB (2x4 MB) Level-2 cache v Support
BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay
-1- GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay Introduction The GV Hot Swap Backup Center System, designed for large scale video surveillance deployments, provides a secure remote backup
Mini server, BIG performance AC100
Mini server, BIG performance AC100 The AC100 is the perfect first server for your small business. This tiny dynamo packs a wealth of enterprise level features including Intel Xeon processors, ECC memory,
BIOS Update Release Notes
BIOS Update Release Notes PRODUCTS: DG31PR, DG31PRBR (Standard BIOS) BIOS Version 0070 About This Release: February 8, 2010 Integrated Graphics Option ROM Revision: PXE LAN Option ROM Revision: Improved
McAfee Data Loss Prevention
Hardware Guide Revision B McAfee Data Loss Prevention 1650, 3650, 4400, 5500 This guide describes the features and capabilities of McAfee Data Loss Prevention (McAfee DLP) appliances to help you to manage