Intruder alarm system Engineering Information
|
|
|
- Alexander Curtis
- 10 years ago
- Views:
Transcription
1 ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE 8 ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE 8 Power Power Chime Omit Chime Omit Prog Prog Set Set PA PA Chime Omit Prog Chime Omit Set PA Prog Set PA Intruder alarm system Engineering Information Power 8 Power Accenta 8SP 0 Accenta G panel with remote LED keypad 8EP Optima G panel with built-in keypad 8 Power 0 Power Accenta AccentaG mini AccentaG mini 8SP 00 Accenta mini G panel with remote LED keypad The above intruder systems are designed to comply with the installation requirements of BS 8/8. 8EP Optima compact G panel with built-in keypad This manual provides information on Installation design, panel fixing, wiring, power up and programming of the intruder panels.
2 Features Features 8 z RKP MEM 8 OUTPUT REMOTE SET PART SET 0 8 zones, all programmable for Security, Fire, H Fire, PTS or keyswitch applications PA input input Outputs for Bell and Strobe Access level Codes, User, User, Engineer and Duress, all programmable fully selectable part set programs Chime on any zone 8 event memory Programmable timers including bell cut off Walk Test facilities Quick set feature Remote keypad with on board PA and illuminated keys standard for Accenta panels and Optional for Optima panels Option for connection of Lighting controllers Options to connect up to four remote keypads / Lighting controllers NVM for protection of engineer programme digital outputs for a wire-in digital communicator, Red Care STU or dialler (Not applicable for Optima compact G panel) Service warning indicator, programmable between 00 and 800 set and unset events Battery capacity of up to :.Ah in Accenta/Optima G mini enclosure Ah in Accenta/Optima G enclosure Optima G and Optima G mini are supplied with built in keypad Accenta/Optima G Intruder system Contents Features Installation Design Fixing Wiring the system network Connect Remote Keypads / Lighting controllers Security zones Push to set zone Remote keyswitch zone Fire zone PA circuit Extension speaker Bell Output (External sounder) V Supply output Set Remote signalling Input and Outputs Filtering of Intruder alarms Factory set condition First Power up Mains Connection Testing the system Engineer program mode To exit System indications To enter Engineer program mode To Exit Engineer program mode To reset panel to Factory set conditions Access Codes Programs Zone Function per Program Exit Modes program Programs, and Alarm and Walk tests Communicator tests Flag A Options Flag B options Viewing the event log Zone Type Zone Attributes Bell and Service Timers Re-arm and Anticode reset code Lighting controller Faults Specification Servicing organisation Details Parts Quick Reference PI issue _/0
3 AccentaG mini ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE 8 Power Power Chime Omit Prog Set PA Accenta/Optima G intruder system Installation Design The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding and the follow the procedures and advice contained in this manual. Plan the position of each part of the alarm system and the cable runs. Detectors should be sited with particular regard to the degree of coverage required and the function of each of the zones. All of the system wiring is connected directly to the panel. The Accenta panel may be concealed inside a cupboard or loft space, but it must be installed within the protected premises and in a position which is convenient for a mains supply. The Optima panel may be installed near an entry/exit point. 0 8 Accenta The Remote keypads (RKPs) should be mounted in positions which allows ease of operation for the system users, typically within the entry/exit route close to the final door and the master bedroom. Additional internal sound speakers are recommended, these will provide high volume alarm tones and low volume entry/exit tones. Speakers should be positioned to provide good sound distribution throughout the building and so that the exit tone is audible outside the main entry / exit door. This will enable the system operator to check that the system is setting correctly. Finally note that the total current output of this I control system (in alarm TOTAL condition) is Amp when supported by a fully charged battery. Calculate the total current consumption of every part of the system including the panel, remote keypads, bell/sounders, strobes and detectors to ensure that this rating is not exceeded. Depending on which area you live, you may be LA required, by law to notify the Local Authority and Police of the new security alarm installation. The local authority requirements may differ from area to area, therefore, it is advisable to contact local environmental officer to obtain full details of your area requirements. Fixing Caution: When positioning the control panel ensure that it is located in a dry place away from damp areas. The Accenta mini G enclosure is illustrated here, however the procedures for the other panels are similar. a. Remove the front cover(s) from the panel. Disconnect the transformer wires from the transformer marked AC terminals on the board. Carefully remove the PCB by gently pushing down the holding clips on the bottom edge of the PCB and withdraw it from the base. PI issue _/0 Installation Design
4 Accenta/Optima G Intruder system Mounting holes Cable entry holes Fixing Note: When replacing the PCB align it on the round support pillars to the bottom and allow it to click down past the clips at the top of the case. Refit the transformer wires into the terminal. b. Fit the panel to the wall with suitable fixings. Ensure the wall surface is flat to prevent base distortion. There are cable entry holes provided in the rear of the base and around the outside edges through the thinned out plastic sections which may be cut away as required. c. The hole provided adjacent to the mains transformer is a dedicated mains cable entry point. Mounting holes Board There are four fuses mounted on the circuit board, all are 0mm quick blow. F.A - to protect the +ve line of V battery F A - to protect the RKP V supply F A - to protect the Speaker V supply F A - to protect the Bell and Strobe supply As supplied, wire links are fitted across the PA and terminals to represent a closed circuit. Communicator is not fitted to Optima compact G panel ABORT L/FAIL +V 0V FIRE PA INT SET CONF Keypad and LEDs (except Power LED) are not fitted to Accenta G and Accenta mini G panels A SOUND COMMS +V J 0V TAMP RKP FUSE J F 8 D D D D D D D D8 PA + J VOLUME VR TAMP +V 0V - - TAMP + T A STROBE SCB J D8 D D0 D D B SET BELL CHIME OMIT RESET BELL/STROBE F V / SPEAKER F BATTERY F A A.A PROG SET J + - AC BATT Factory fitted links PI issue _/0
5 Accenta/Optima G intruder system Wiring the system Caution: Always power-down the panel when wiring external circuits, to prevent damage to the panel electronics. Systematically wire and test each circuits.: Zone, circuit and PA circuits Finish by wiring any additional extension speaker sounders, external bell/sounder, strobe and the V supply. network The circuit is used to protect all cables and detectors in the system from unauthorised access including the panel and RKP covers. The zone and PA tampers should be series wired and connected to the TAMP terminals. Terminals T&Aarefortheexternal bell / sounder tamper. The TAMP terminals at the bottom left of the PCB are for the RKP tampers. alarms that occur in the mode operate internal sounders only. alarms in Set cause a full alarm condition. is indicated on the control panel and RKPs by the indicator. Connect Remote Keypads / Lighting controllers Note: Where an Accenta G or Accenta mini G panel is being installed ensure there is at least one remote keypad wired to the panel before first power up. A combination of up to four remote keypads and lighting controller can be connected to the panel. Security zones Door Contact Door Contact Panel Board J 8 Alarm PIR + - Tamp PIR Terminal block is not supplied PA TAMP +V 0V + - Unused zones must be programmed as Unused. Note: The G range of panels are not supplied with wire links for unused zones. All unused zones must be programmed out by setting them to disabled using the Zone Type function see page. It is recommended that no more than 0 magnetic contacts are connected to the same zone. Wiring the system OPTI-CAM Lighting Controller Board LD R SOUND COMMS V GND Keypad Board 0V V COMMS SOUND TAMP Keypad Board 0V V COMMS SOUND TAMP Panel Board A RKP FUSE F Maximum of up to Remote Keypad / OPTI-CAM Lighting Controller combination allowed (See also the instructions supplied with the OPTI CAM lighting controller) If only one Remote keypad is being used then connect TAMP back to the panel PI issue _/0 J SOUND COMMS +V 0V TAMP
6 Push to set zone Push to set zone Any zone can be wired and configured as a Push to Set input. This can be a standard door bell push located outside the premises After starting the exit timer the building is vacated. As the switch is then momentaraily closed, a chime tone is produced and the system Sets. Sometimes referred to as Terminate Set this facility is mandatory for communicating systems installed to NACOSS guidelines Panel Board J Remote keyswitch zone Any zone can be wired and programmed as a keyswitch input and used with a remote keyswitch or lock switch. For security reasons it is recommended that a tamper proof switch is used and that the switch wiring is not accessible from outside the premises. Panel Board J 8 Note: The push to set switch can be connected to any zone. The zone must be programmed for PTS application. 8 PA TAMP +V 0V + - Press to Set Switch PA TAMP +V 0V + - Accenta/Optima G Intruder system would have to be momentarily turned to its Set position then returned to its Unset position. The keyswitch will always Set program. It will also Unset the system or switch off an alarm activation. To after an alarm and return to mode, the key on the RKP will have to be pressed. Fire zone Any zone may be programmed as a fire zone. This will automatically exclude the availability of the zone from programs and normal security applications. Panel Board J 8 Note: Fire detector with relay base for output to intruder system. PA TAMP +V 0V + - Fire detector There are two types of fire zone, Standard and hour type. The Standard fire zone detects fires only when the system is Set, where as the hour fire zone detects fires all the time and will operate whether the system is Set or Unset. A fire will cause a distinctive internal sounder tone. The external sounders will pulse on and off at second intervals and all RKP indicators will flash the affected zone. Note: A keyswitch can be connected to any zone. The zone must be programmed for keyswitch application. Keyswitch The keyswitch may be used to Set (open contacts) or Unset (closed contacts) independently of RKPs. However in this situation the keyswitch may have to catch up with the system. For example if the system is Set via an RKP and Unset with the keyswitch, it PA circuit Any quantity of normally closed type personal attack button may be wired in series and then connected to the PA circuit. Operational in and Set, the PA circuit will cause a full alarm condition when activated. PA is indicated on the control panel or RKP as. PI issue _/0
7 Accenta/Optima G intruder system Panel J 8 Board PA TAMP +V 0V + - A control marked VOLUME in the centre of the PCB may be used to adjust the low volume entry/exit tones to suit environmental conditions. To adjust this control, partially lift up the top cover. Panic Button Panic Button PA buttons may be fitted near the front door, or in a bedroom. Extension speaker Extension speaker may be connected to the loudspeaker terminals to produce high volume alarm tones and low volume entry / exit fault tones. Panel Bell Output (External sounder) The bell is usually installed in a high position from where the bell could be seen and heard. Terminal TADBareforconnection to the external bell or sounder. These terminals provide a power/hold-off supply, sounder trigger and tamper circuit to protect the external sounder housing. Panel Board J - + STROBE T A D B SET SCB BELL + - BELL/STROBEF A Extension speaker VOLUME VR STROBE - + T SCB A D B BELL + - J SET Board BELL/STROBEF A A VSPEAKER F + - T E A D B STROBE Extension Speaker Extension Speaker Up to two ohm extension speakers may also be wired across the speaker terminals. Mounted in convenient positions within the installation the extension speakers will reproduce all of the alarm tones generated by the control panel. Sonade The terminals are summarised as follows: T - -Ve tamper return A - -Ve supply (0V) D - +Ve supply (V) B- -Ve Sounder trigger For ease of installation, ADE sounders and modules use the same markings. Where a discrete bell sounder is used, it should be connected to terminals D&B.Terminals T & PI issue _/0
8 A are then used for tamper protection for the sounder housing. Panel Board J - + T A D B SET STROBE SCB BELL + - BELL/STROBEF A # Terminal block is not supplied Accenta/Optima G Intruder system Remote signalling Input and Outputs These outputs are not applicable to the Optima compact G panel. These terminals have been provided for connection to remote signalling equipment such as a digital communicator, Red Care STU or speech dialler. + - T E A D B STROBE # + - T E A D B STROBE Note: The operating polarity of the Communicator output terminals are programmable. V Supply output Where self contained / powered sounders are used, carefully follow the manufacturers instructions, match each of the terminals to those above. V Supply output The V output is to power detectors which require a voltage supply (PIR detectors etc). The supply is present at all times and may be used to supply a total load of 0mA. Set Sonade Sonade The output, marked SET is used with latching detectors. The output becomes positive on correct Set of the system and is removed at the commencement of entry time or entry of the valid user code. L/FAIL This is a telephone line fail input which is held at approximately V by the panel circuitry. The input is activated when pulled to 0V by the telephone line fault output of the communicator. This is usually a voltage free relay or open collector transistor. When a telephone line fault occurs in the mode the panel provides an audible double beep every 0 minutes. This indication is automatically cleared when the fault is removed. A telephone line fault which occurs while the system is Set will not cause an alarm condition but any bell delay which is programmed will be cancelled and any intruder alarm which is triggered will operate instant sounders. V 0V These terminals provide a V supply for the communicator up to a total load of 00mA. The output is protected by a 0mA thermal fuse. If this fuse operates it may be reset by removing the load and allowing a few seconds for it to recover. OUTPUT PORT By default these outputs are programmed as active low output. They are held at V and fall to 0V when active, it can source or sink 0mA. The output polarity can be programmed. 8 PI issue _/0
9 Accenta/Optima G intruder system These outputs would normally be connected directly to the input channels of wire in type communicators and STUs. Alternatively each output can be used to drive a relay(coil resistance > 00 ) connected between the output terminal and the V supply terminal. The relay will energise when the output port operates. It is recommended that a back EMF protection diode is used in parallel with the relay coil. FIRE The fire output operates when the fire zone is triggered. PA The PA output operates when a PA alarm is triggered or a duress code is used. INT The intruder output is operated when an intruder condition is triggered whilst the system is set. SET The Set output operates whenever the system becomes set and is used to indicate opening and closing. ABORT Operates when an intruder alarm condition is switched off. CONF The confirmed alarm output operates when independent zones are activated during the same alarm condition. Important Notes a. Each output has been configured as active low and will normally require the EPROM or NVM for the communicator or STU to be programmed as active low or positive removed. However there may be differences between some pieces of equipment and some Alarm Receiving Centres (ARCs). b. Where the communicator is powered from an external source, not the panel and the outputs are being used without relays, the panel and external power supply will require a commoned negative supply rail. c. If the communicator is not fitted inside the panel and abort is being used, care should be taken to ensure that the abort connection cannot be damaged or severed as this could cause the ARC to incorrectly filter an alarm signal. d. It is very important that communicating systems are fully tested and that all signals are correctly received at the ARC when the system is installed and serviced. Filtering of Intruder alarms A condition of most police Force Policies and under the guidance of NACOSS NACP (Code of Practice for intruder Alarm Systems Signalling to Alarm Receiving Centres) is that all intruder alarm signals received by an Alarm Receiving Centre (ARC) must be filtered to establish their validity before passing to the police. The exact method of filtering should be decided according to the regional Police Force Policy and ARC procedures. In general, the panels offer the following methods which could be used to filter an alarm. Set/Unset A Set or Unset signal which is received by the ARC at around the same time as an intruder signal can be used to filter the alarm. Abort Output The abort output operates whenever a user code is entered or a keyswitch is used to switch off an intruder alarm condition. When an abort signal is received by ARC at or around the same time as an intruder signal, the alarm can be filtered. Restore of the Intruder Output The intruder alarm output is restored to V whenever a user code is entered or a keyswitch is used to switch off an intruder alarm condition. Where an intruder alarm is shortly followed by a restore at the ARC, this can be used to filter the alarm. Remote signalling Input and Outputs PI issue _/0
10 Factory set condition Factory set condition User code User code Notprogrammed Duress Code Notprogrammed Engineer Code Bell Duration minutes Bell Delay Nodelay Program Zone Timed Zone Time Inhibited Zones Immediate Exit time seconds Entry seconds Exit mode timed Program Zone Timed Zone Time inhibited Zone Immediate Exit time seconds Entry time seconds Exit mode Disabled Program Zone Timed Zone Time Inhibited Zone Immediate Exit time seconds Entry time seconds Exit mode Disabled Security Zones Zones 8 Standard Fire zones ----None programmed hour Fire zones -----None programmed Push to set zones None programmed Keyswitch zones None programmed Double Knock zones ----None programmed Omit prevent zones- ----None programmed Zone debounce period mS ALL zones Accenta/Optima G Intruder system Flag A Silent PA No RKP PA Enable Yes Engineer No Anti Code No Door bell on push to set - - No Single key setting No Strobe on setting No External bell on Fire No Flag B Note: The entries marked # are not applicable for Optima compact G panel. #Communicator Output active high No(active low) #Line Fail active high No(active low) User PA No User Fire No #Program to report Yes #Program to report Yes #Program to report Yes Rearm counter (re-arms) Service counter Off Site Code Light Controller Light Threshold % Light Hold Time seconds Light Channel Nozones assigned Light Channel Nozones assigned Light Channel Nozones assigned Light Channel Nozones assigned Light Channel Nozones assigned Light Channel Nozones assigned Light Channel Nozones assigned Light Channel Nozones assigned 0 PI issue _/0
11 Accenta/Optima G intruder system First Power up Before power up for Optima compact only - fit the top cover on to the base and connect the speaker wires. Leave the cover in position throughout the reset of the installation. a. Check that the factory fitted links are connected to terminals PA, TAMP and T-A. b. Fit the battery wires to the BATT terminals on the PCB, Red to + and Black to -. Panel BATTERY F.A (red) + Black - V battery + - AC BATT N E L ma Fuse Transformer c. On connecting the battery the system will now go into alarm condition and is indicated Board and there is an audible indication.. d. Fit the cover to hold down the tamper spring at the bottom centre of the PCB. e. Enter the user code: 0 (factory set at 0). The alarm condition will cease and the system will go to mode. f. Immediately enter the engineer code Prog. The system is now in Engineer program mode and can be programmed. Note the Alarm J indicator is lit. Note: The G range of panels are not supplied with wire links for unused zones. All unused zones must be programmed out by setting them to disabled using the Zone Type function see page. Mains Connection The mains power should be connected using a core cable of not less than 0.mm sq. from a fused spur to the mains connector inside the control panel. The Amp fused spur must be located close to the control panel. Dedicated mains supply from consumer unit. Panel BATTERY F.A (red) + Black - V battery Board + - AC BATT Transformer N E L ma Fuse Note: The mains supply must be connected by a technically competent person and according to current IEE regulations. CAUTION: To avoid the risk of electrical shock you must always totally isolate the mains supply before opening the control panel cover(s). Mains Input Fuse rating: ma, 0V type T (anti surge) and of a type approved to IEC part sheet III. On connecting the mains supply to the panel the power indicator is lit. Power A Fused Spur unit J First Power up PI issue _/0
12 Testing the system Testing the system Complete the wiring of the system and then: fully test the system and ensure it is fault free. Fully program the system Fill in the installation log at the back of the manual and retain if for future reference. Finally explain the operation of the system to the end user. The Operating Instructions are attached to the centre of this manual. Detach them and leave them with the user. Engineer program mode The panel may be programmed to suit a wide variety of installations.. Once the engineer program mode has been accessed, each configuration may be changed in any order. As each configuration is completed the system will automatically return to top level of engineering program mode. Before entering engineer program mode the system should be in the mode, with the and Power indicators lit. Key LED Off Internal sound LED steady On indication Sound description NOTE: In general a flat beep is an indication of an incorrect key press. External devices Bell LED flashing indication o/p ARC Output to Alarm Receiving Centre Communicator outputs are not applicable for Optima compact G panel Strobe Accenta/Optima G Intruder system System indications - Unset system indication - Set system indication To enter Engineer program mode Note: The factory configured engineer s access code is. If however this code is changed then enter the appropriate code. Prog To Exit Engineer program mode Power ZONE-8 Momentarily On Power To reset panel to Factory set conditions CAUTION: All configurations of the panel are restored to factory default conditions. Within seconds of powering up the panel reset beeps To exit Quit the current function Leave program menu Down one menu level PI issue _/0
13 Accenta/Optima G intruder system Access Codes There are four codes used in the system, all are digit and can be set to any number from 0000 to. The access codes ensure that only authorised users can operate the system. User and codes The user and user codes have the same operation for testing, Setting and Unsetting, but user code which is usually considered to be the Managers code has the authority to add, change or delete the user code and duress code. Duress code Should be used in a hold up situation where there is pressure to Set or Unset the system. Entry of the code will allow the system to work normally but also generate a silent PA type alarm by operating the PA communicator output. Engineer code Accesses the Engineer Program mode to allow the system to be programmed. The engineer code will not set or unset the system. If configured the Engineers access code can be used to reset the system after an alarm. Note: Entering an invalid user code will operate the code tamper. After nineteen incorrect key pushes a full alarm condition will be generated. Example: To change User code to Press: Prog Enter Engineer program mode 8 Codes Change User code Change User code Change Duress code Change Engineer code ZONE - n n n n New code Rising beeps ZONE - Exit codes NOTE - The sounder will produce a flat beep if the code is rejected. The Code is rejected if it is already in use. 8 Leave engineer mode Access Codes PI issue _/0
14 Programs Programs The panel uses Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function. The examples below show how typical Programs could be used in a house. Program : To arm all of the zones and become Set as the user leaves the property and closes the final door. Program : To protect the perimeter of the property in the evening and become Set after say 0 seconds. Program ; To protect the downstairs areas of the house at night and become Set instantly and silently. Note: The above are purely examples. The installer must program the panel to configure all the circuits to the customer s exact requirements. Zone Function per Program Timed : This function would be used to protect the main entry/exit door of the entry route. Time inhibited : This is a zone which, on setting the panel, allows access to the Entry / Exit zone. However, if the panel is set and an time inhibited zone is triggered before an Entry /Exit zone then an alarm will be generated immediately. Immediate: This is a zone which will, when entered, go into alarm when the panel is set. Accenta/Optima G Intruder system Exit Modes program Timed A timed Program will become Set as the Exit timer expires. Terminated Set This sets an infinite time out, which will only set once the PTS input is operated. Final Door A final door program will be Set seconds after a timed zone has opened and closed. Silent Set This operates exactly the same as Timed but completely silent without the internal sounder signal. Note: If a program is not selected when the user Sets the system, Program will automatically Set. Therefore Program is usually considered as the Full Set Program containing all of the zones. Unused : A zone that is programmed as an Unused zone by the Engineer, then is ignored by the panel. Primarily used for Part set options. PI issue _/0
15 Accenta/Optima G intruder system Programs, and Prog Example: To configure Program Exit mode to Final door set, Press: Prog Prog Enter Engineer program mode Set up program 0 Deselect all zones Zone Press number button to select Program to be configured Zones, and Program Program Program Used Zones Timed Zones Time inhibit zones Entry time Exit time Zone Zone Zone Factory defaults All Zones Zone Zone Zone Zone Press number button to select / deselect zone 8 Input Entry/Exit time respectively 0 0 Zone Zone Zone Zone Zone Zone Zone 8 Appropriate Zone indicator is lit to show selected zones Zone n selected Zone n deselected 0 seconds duration 0 seconds duration Programs, and Exit mode 0 0 seconds duration (factory default) Press a number button to select the appropriate Exit mode 0 Disabled Terminated set Final Door Set Silent set (use exit time) Factory default For Programs and Timed Zone for Program Zone Zone Zone Exit to Program and complete used zone set up Exit to Setup program Exit Set up program Leave engineer mode PI issue _/0
16 Alarm and Walk tests Accenta/Optima G Intruder system Example: To start bell test and thereafter to stop bell test. Prog 0 Enter Engineer program mode Alarm test Press zero to turn off options,, and before selecting a new one Strobe test Strobe On Bell test Bell on Low volume sounder internal low volume sound Alarm and Walk tests High volume sounder Walk test internal high volume sound Strobe x for zone x for zone x for zone flat x for zone flat x for zone flat x for zone 8 Strobe On Appropriate zone lights are lit(latched) Zones Rapid for PA Rapid for 0 OFF Exit current level Leave engineer mode The alarm test function allows you to test the Strobe, Bell, Low and high volume sounders of the system. The walk test function allows each detector to be checked in order to verify that they are functioning correctly. PI issue _/0
17 Accenta/Optima G intruder system Communicator tests Note: These tests are not applicable to Optima compact G panel. Press number button to select / deselect test Example: To test intruder output and thereafter stop the test. Prog 0 Enter Engineer program mode Communicator Tests Fire Output PA Output Intruder Output Open /Close Output Abort Output Confirmed Output Communicator fault 0 Stop the tests Exit current level Appropriate Zone indicator is lit to show a selected output Factory defaults Zone Zone Zone Zone Zone Zone Leave engineer mode Zone 8 The Zone 8 LED is lit to show there is a communicator line fault. Flag A descriptions: Silent PA : When this flag is set and on operating PA will cause a Silent PA alarm. RKP PA Enable: When this flag is set the keypad PA buttons are enabled. Engineer : When this flag is set an Engineer code must be entered to reset the system after a full alarm. When the flag is clear the system can be reset by the user. Anti-code : When this flag is set it enables the anti code reset function. Flag A Options Press number button to select / deselect flag setting Example: To set the panel for engineer reset, Press: Prog Enter Engineer program mode Flags A Zones -8 Momentarily On 8 Silent PA RKP PA enable Engineer reset Anti-code reset Enable Door bell on PTS Enable single key setting Enable strobe on setting Enable Bell in Fire Exit current level Appropriate Zone indicator is lit to show flag setting Factory defaults Zone Leave engineer mode Zone Zone Zone Zone Zone Zone Zone 8 Enable Door bell on PTS: When this flag is set it allows a zone circuit programmed as PTS to operate as a door bell. Enable single key setting:when this flag is set it allows the panel to be set by pressing the SET button (ie code entry is not needed), however a digit code is needed to Unset the panel. Enable strobe on setting: When this flag is set the external strobe will flash for seconds once the panel has successfully set. Enable external Fire bell: When this flag is set the system bell will sound seconds On / seconds Off during a fire alarm. Communicator tests PI issue _/0
18 Flag B options Flag B options Note: The following settings: Communicator output, Line Fail, Program, and to report are not applicable to Optima compact G panel. Press number button to select / deselect function Example: To set the panel for user to reset PA, Press: Prog Enter Engineering program mode Flags B Zones -8 Momentarily On Communicator output active high Line fail active high User PA User Fire Program to report Program to report Appropriate Zone indicator is lit to show flag setting Factory defaults Zone Zone Zone Zone Zone Zone Program to report Zone 8 Entry deviate Zone 8 Exit current level Accenta/Optima G Intruder system Viewing the event log Example: To view up to 8 previous events and thereafter to stop the event scroll, Press: Prog Chime Enter Engineer program mode Chime View the event log Automatic event scroll Starting from event to 8 To manually scroll View event (oldest event) View event 8 Chime View event View event View event View event View event View event 8 (Newest event) Resume automatic scroll Zone, PA and indicators will be lit to show zone in alarm. Flashing indicates the first zone in alarm. indicates status of panel at the time of alarm Leave engineer mode Stop event scroll / view Leave engineer mode Flag B descriptions: Communicator output active high: When this flag is set it configures the polarity of communicator outputs to active high, that is output is held at 0V rising to V in alarm. Line fail active high: When this flag is set it configures the polarity of line fail input. User PA: When this flag is set it permits the user code to reset the system after a PA alarm, even if Engineer reset flag is set. User Fire: When this flag is set it permits the user code to reset the system after a Fire alarm, even if Engineer reset flag is set. Program n to Report: When this flag is set it allows program n to activate the intruder and confirmed outputs. (Main use is to prevent a night time program from communicating). Entry deviate: When this flag is set it permits an immediate zone to be activated during the entry period without causing a full alarm. 8 PI issue _/0
19 Accenta/Optima G intruder system Zone Type The G range of panels are not supplied with wire links to terminate unused zones. Therefore all unused zones must be programmed out by setting them to disabled using the Zone Type function. Example: To disable an unused zone 8, Press: Prog 8 0 Enter Engineer program mode Zone Configuration All Zones Press a number button to select Zone to be configured 8 Zone type Zone type Zone type Zone type Zone type Zone type Zone type Zone 8 type Press a number button to select zone type 0 Disabled Security Fire h Fire PTS Keyswitch Appropriate Zone indicator is lit to show Zone type Factory default Zone Zone Zone Zone Zone Zone Type Exit to zone type Exit zone configuration Leave engineer mode PI issue _/0
20 Zone Attributes Accenta/Optima G Intruder system Example: To configure zones and for Double knock operation, Press: Prog Enter Engineer program mode Zone Attributes Double Knock Omit Prevent Zone Delay ZONE-8 Momentarily On 0 Deselect all zones Zone Attributes Press number button to select / deselect zone delay, Omit zone or Double knock 8 Zone Zone Zone Zone Zone Zone Zone Zone 8 Appropriate Zone indicator is lit to show zone having 800mS delay, Omit prevent or double knock. Zone n selected Zone n deselected Factory defaults: All zones have delay of 00mS No Zones are set as omit prevent No zones are in double knock Exit to zone type Exit zone attributes Leave program mode Zone attribute descriptions Double knock: The panel will require activations of the same detector before causing an alarm condition. This setting is used as a false alarm measure. Note: Double knock must not be used on zones having magnetic door/window contacts. Omit Prevent: The panel will prevent the zone from being omitted by the user when setting the system. Zone Delay: The panel programs a zone delay to 800mS to give extra immunity to false alarms. 0 PI issue _/0
21 Accenta/Optima G intruder system Bell and Service Timers Example: To set bell timer for 0 minutes duration, Press: Prog 0 Enter Engineer program mode Timers and Counters Zone 0 0 Continous operation Bell timer Bell delay timer Zone 0 0 minute bell duration minute bell duration Service timer Re-arm counter (00 to ) Anti-code reset site code ZONE-8 Momentarily On Zone Zone 0 minute bell duration 0 0 minute bell duration (factory default) minute bell duration No delay (Factory default) minute bell duration minute bell duration minute bell duration Bell and Service Timers 0 Service timer disabled (Factory default) 00 Set/Unset Zone 0 0 minute bell duration minute bell duration Press a number button to select Service timer 00 Set/Unset Zone 00 Set/Unset Zone 00 Set/Unset Zone 00 Set/Unset Zone 00 Set/Unset Zone 00 Set/Unset Zone Appropriate Set / Unset values LED is lit Lit when selected Exit Set/Unset Zone 8 Exit Timer and counters Leave engineer mode PI issue _/0
22 Accenta/Optima G Intruder system Re-arm and Anticode reset code Example: To set panel re-arms to 0 times before panel is shut down, Press: Prog 0 Re-arm and Anticode reset code Enter Engineer program mode Timers and Counters Bell timer Bell delay timer Service timer Re-arm counter (00 to ) Anti-code reset site code Zone Zone Zone Zone factory default code 0 0 No re-arm 0 re-arms 0 re-arms (factory default) re-arms Re-arm After an alarm the panel will automatically reset itself when the bell timer has expired. Any zones which still remain open at that time will be omitted automatically. Note: By default there are automatic re-arms before the panel is shut down. Anti code reset (Engineer reset) If the system has been programmed to be engineer reset, after an alarm it will lock out and the RKP will continually display the cause of the alarm. The engineer would then be required to attend the site and use the engineer code to reset the system. Where anti-code reset has also been enabled, the RKP will still show the alarm cause and also display a digit 'quote code' by sequentially flashing zone indicators -8. At this point the end user would contact the engineer. After determining the cause of the alarm and deciding that a engineer call was not necessary, a digit anti-code would be given to the user which would reset the system. This anti-code is generated from a small computer program which is installed at most UK Alarm receiving Centres, or alternatively can be run on a PC by the engineer. Exit to Timer and counters Leave program mode Security of the anti-code reset system is maintained by a digit site code which is set up in the anti-code generator programme. The same digit site must also be set up in the control panel during installation. PI issue _/0
23 Accenta/Optima G intruder system Lighting controller Example: To assign zones and to lighting controller channel, Press: Prog Enter Engineer program mode Lighting Controller Press a number button to select the appropriate light channel All Zones Channel assigned zones Channel assigned zones Channel assigned zones Channel assigned zones Channel assigned zones Channel assigned zones Channel assigned zones To assign zones to channel press to select and again to deselect zone (Factory default: No zones are selected) Appropriate Zone indicator is lit to identify its assignment to channel Zone n assigned to the channel Zone n not assigned to the channel Lighting controller 8 Channel 8 assigned zones 8 Exit current level Hold time (0- seconds) (0 seconds factory default) Exit Lighting controller Prog Set the light threshold level (0 - %) Leave program mode Zone Zone % threshold or 0 second hold time acknowledge % threshold or second hold time 0% threshold or 0 seconds hold time Exit Lighting controller Leave program mode PI issue _/0
24 Faults Faults Fault conditions are often the result of minor installation errors or misinterpretation of the equipment being installed. The following points outline the most common installation and commissioning faults. a. As supplied the user code is 0 and the engineer code is. Both codes will revert back to these default settings on clearing the NVM. b. The Engineer Program is accessed directly from mode via the engineer code. c. If a tamper, PA or Hr fire fault is present on the system, it will go to a lock out condition (showing the appropriate indication). The keypad will not produce any audible responses and the system will not operate until the fault has been found and rectified. d. The most common cause of a zone not responding to detection is incorrect wiring. Normally closed detectors must be wired together in a series loop before connecting into the appropriate ZONE terminals. s are series wired in the same manner. e. Where a permanent zone fault is showing and the loop resistance is found to be in order, the most probable cause is a short circuit between the zone wiring and the tamper wiring. When measured with a multimeter the series resistance between the zone and tamper wiring should be infinitely high. f. If totally lost as to the cause of a fault, remove ALL wiring from the PCB. Refit the -links and test the system. Never fit links to any positions other than those marked on the PCB. Accenta/Optima G Intruder system g. Before testing or replacing any fuses, ALL power must be removed. Fuses which fail continually are almost certainly the result of a short circuit or low resistance across the V supply or external bell supply (terminal D). h. Whenever working close to the mains supply or connector, you should exercise extreme caution. Always isolate the mains supply before removing the control panel covers. i. Where normally open detectors are connected to adjacent zones two pull-up resistors (not supplied) of value kohms must be installed. Panel The example below shows how to wire normally open detectors on zones and. J Panel J Board 8 K ohms Normally open detectors PA TAMP +V 0V + - The example below shows how to wire normally open detector on zones and a normally closed detector on zone. Board 8 Kohms Normally open detector Normally closed detector PA TAMP +V 0V + - PI issue _/0
25 Accenta/Optima G intruder system j. Where Pressure mats are being used these must be connected to a zone in the manner shown. The example below shows pressure mats connected to zones. Panel Specification Indicators on Control panel or RKPs 8 Zones PA Board J 8 Bell Output Strobe Output Extension Speaker Exit/Entry timers seconds Zone Input Delay Set +ve Output Current Consumption Control panel Kohms Pressure Mats Zone -8, Power,, and +ve loop, programmable function in each program -ve loop, internal sounders in Full alarm in Set +ve loop, always active V, adjustable timer (- mins) or continuous V latching ohms ( maximum) 0mA each Programmable (0-0 seconds) 00 or 800mS 0V in (sinking 0mA) Standby 80mA Alarm 0mA PA TAMP +V 0V + - Current Standby 0mA consumption RKP Alarm 0mA Low voltage.8v dc stabilised (+/- output %) up to 0mA Accenta/Optima G mini/compact - V,. Rechargeable or.ah Battery Accenta/Optima G - V, up to Ah Charge Voltage.8V dc (+/-%).A & A 0mm quick PCB Fuses blow ma, 0V type T (anti-surge) type Mains Input fuse approved to IEC, part sheet III Amp when supported Total Current by a fully charged Output battery Mains Supply 0V (+/-0%) 0Hz Voltage max load 0.A Total Current Output Mains Supply Voltage Ambient Operating temperature Enclosure construction Dimensions Amp when supported by a fully charged battery 0V (+/-0%) 0Hz max load 0.A 0 0degC mm Polycarbonate Accenta/Optima G mini/compact H 00mm W mm D mm Accenta/Optima G H 0mm W 0mm D 80mm RKP H 8mm W mm D 8mm Specification PI issue _/0
26 Specification Index! V Supply... 8 hour fire zone.,,0, Part Set... A AC terminals... Access Codes... Alarm test... Anti Code. 0,, ARC... B Battery..., Bell Delay...0 Bell Duration.. 0 Bell in fire... Bell Output..., Bell timer.... Board... BS 8/8. C Charge Voltage.. Chime... Codes.... Communicator.. Communicator Outputs 8,0 Current Consumption D mode... Detectors... Dimensions.... Door bell...0, Double knock.. 0,0 Duress Code... 0, E Engineer Code.. 0, Engineer program mode, Engineer.. 0, Entry deviate... 8 Entry time...0, Event log...8 Exit Mode...0,, Exit time...0, Exit/Entry timers. Extension speakers External bell on Fire 0 F Factory set conditions 0, Faults... Final door set..., Fire zone..., Flag A... Flag B...8 Full Set... Fuses..., H Hold time.... I Immediate zone. K Keyswitch zone. 0, L light channel... Light Hold Time. 0 Light threshold.. 0, Lighting controller,0, Line Fail...0 Local Authorit.. M Mains...., Managers code.. N NACOSS..., NACP... Normally closed detectors Normally open detector NVM..., O Omit prevent... 0,0 Operating temperature P PA...,, PA fault.... PCB Fuses... Pressure mats... Program...0, Program to report0,8 Program...0, Program to report0,8 Program...0, Program to report0,8 Programs, and PTS zone..., Accenta/Optima G Intruder system Push to Set...,0 Q Quick set... quote code... R Re-arm... Rearm counter.. 0 Red Care STU..,8 Remote keypad.., Remote keyswitch RKP...,0, RKP PA enable.. S Security Zones..,0, Service counter.. 0 Service timer... Set...8 Set system... Silent PA...0, Silent Set..., Single key setting 0, Site Code...0 Speakers... Specification..., Standard Fire zone,0 Strobe on setting. 0, T TADB fault... network. Terminated Set..,, Time inhibited zone, Timed.... Timed exit... Timed zones... Total current... U Unset system... Unused zone..., User code... 0 User... User and codes User... User code....0 User reset fire.. 0,8 User reset PA... 0,8 V Volume... W Walk Test..., wire links... Z Zone Attributes.. 0 Zone debounce.. 0 zone delay...0 Zone Input Delay. Zone Type... PI issue _/0
27 Accenta/Optima G intruder system Servicing organisation Details Servicing organisation name: Parts Below is a list of approved parts and accessories. Telephone number: Date of installation: Account Number: Zone Zone Zone Zone Zone Zone Zone Zone 8 Resistance 8SP 0 Accenta G panel 8SP 00 Accenta mini G panel 8EP Optima G 8EP Optima compact G panel 8EP Accenta LED RKP 8EP Accenta LCD RKP 8EP Accenta Speech Dialler 8EP Informa 8EP 8 Extension Speaker 8EP Opti-Cam Lighting Controller A range of detectors are also available, for more information contact your supplier. Area protection and equipment used (eg PIR, Contacts..) Servicing organisation Details PI issue _/0
28 Accenta/Optima G Intruder system Quick Reference Timers and Counters (see page & ) Bell timer Bell delay timer Service timer Re-arm counter (00 to ) Quick Reference Anti-code reset site code Engineer Program Mode Prog To exit engineer program mode Alarm test (see page ) Communicator Tests (see page ) Flags A (see page ) Flags B (see page 8) Zone Attributes Strobe test Bell test Low volume sounder High volume sounder Walk test Fire Output PA Output Intruder Output Open /Close Output Abort Output Confirmed Output 8 Silent PA RKP PA enable Engineer reset Anti-code reset Enable Door bell on PTS Enable single key setting Enable strobe on setting Enable Bell in Fire 8 Communicator output active high Line fail active high User PA User Fire Program to report Program to report Program to report (see page 0) Zone Type (see page ) Zone type Zone type Zone type Zone type Zone type Zone type Zone 8 type Double Knock Omit Prevent Zone Delay Entry deviate 0 Disabled Security Fire h Fire PTS Keyswitch Set up program (see page ) View the event log (see page 8) 8 Codes (see page ) Lighting Controller (see page ) Prog Chime Change User code Change User code Change Duress code Change Engineer s code Program Program Program Used Zones Timed Zones Time inhibit zones Entry time 8 Channel assigned zones Channel assigned zones Channel assigned zones Channel assigned zones Channel assigned zones Channel assigned zones Channel assigned zones Channel 8 assigned zones Exit time Exit mode 0 Disabled Timed Terminated set Prog Channel Hold time (0-s) Set the light threshold level (0 - %) Final Door Set Silent set (use exit time) The panels conform to the requirements of the European EMC and Low Voltage directives, and carries the CE mark For Technical Support : PI issue _/0
29 ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE 8 Power Chime Omit Prog Set PA Chime Omit Prog Set PA Intruder alarm system Operating Instructions Remote LED keypad ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE Power Accenta 0 8 Chime Omit Accenta 8 8EP Optima compact G panel with built-in keypad Prog AccentaG mini Set PA Power Power 0 8 PA These operating instructions cover the following intruder system: 8SP 0 Accenta G panel with remote LED keypad 8SP 00 Accenta mini G panel with remote LED keypad 8EP Optima G panel with built in keypad 8EP Optima compact G panel with built in keypad For Clarity, the information given on setting the system, assume that all Programs use a timed or final door setting routine. Unset system indications Chime Omit Prog Set Key LED Off Internal sound Bell LED steady On indication Sound description NOTE: In general a flat beep is an indication of an incorrect key press. External devices LED flashing indication o/p ARC Output to Alarm Receiving Centre Communicator outputs are not applicable for Optima compact G panel Strobe Unset system indications An unset system will have both and Power Power indicators lit. This is a normal indication when the system is disarmed. Note: If the Power indicator goes off at any time then there is a mains supply failure at the security panel, consult your servicing organisation. Set System indication An active Set system will have only the Power Power indicator lit. This is an armed system indication. PI issue _/0
30 Access codes Operating instructions Contents Unset system indications Set System indication Access codes How to operate Personal How to unset system in alarm Programs, and How to set the system (on program ) Push to Set Switch Keyswitch Set Faults during setting How to unset the system (turn off) How to set program, or How to Quick set How to Omit zone(s) on setting system Fire Alarm How to set Chime zone Operator s Program mode To exit operation at any time How to enter Operator s program mode - - How to view the event log How to create/omit User code How to change current user code How to create/change/omit the Duress code - How to carry out Alarm and Walk tests- - - Servicing organisation details Quick Reference Access codes There are two User codes used in the system, all are digit and can be set to any number from 0000 to, signified by: n n n n The user and codes have the same operation for testing, Setting and Unsetting, but user code which is usually considered to be the Managers code has the authority to add, change or delete the user code and Duress code. User code - 0 factory set User code - not programmed. How to operate Personal Personal buttons on the keypad are used to activate the alarm, irrespective of whether the system is armed or not. Press Simultaneously: Accenta/Optima G Intruder system How to unset system in alarm Enter your code. Entering the code will turn the alarm off and the cause of the alarm will be displayed. After investigation press to clear the indication. n n n n Bell Alarm FIRST ZONE IN ALARM OTHER ZONES IN ALARM Investigate the Alarm ALL ZONE Strobe Off Note: If the alarm indication does not clear, then the system may need to be reset by the installation engineer, contact you installer for further information. Programs, and The panel uses Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function. The examples below show how typical Programs could be used in a house. Program To arm all of the zones and become Set as the user leaves the property and closes the final door. Program To protect the perimeter of the property in the evening and become Set after say 0 seconds. Program To protect the downstairs areas of the house at night and become Set silently. The above are purely examples. The installer has the ability at the programming stage to configure all the circuits to the customer s exact requirements. PI issue _/0
31 Accenta/Optima G intruder system How to set the system (on program ) The green indicator should be showing. Enter your code n n Exit beep n n 0seconds insistent beeps number and check that the system is clear (none of the zone indicators are showing). The sounder will now produce an exit o/p ARC beep tone and you Set output should leave by the approved route. The system will Set as the beep tone stops. Push to Set Switch In some systems a Push to Set switch may be fitted outside the premises near to the main exit door. This should be used to complete the setting procedure once the building has been vacated. As the switch is operated, the exit beep tone will stop and a chime tone will be produced to acknowledge setting. Keyswitch Set Your system may have been fitted with a remote keyswitch. This can be used as an alternative to arming the system with a code and will set Program. Where a keyswitch is used it may be necessary on occasions to allow it to catch up with the system. For example if the alarm was set with a code, to Unset with the keyswitch, it would have to be momentarily turned to Set then returned to Unset. Faults during setting If the system is not clear when you try to Set it, the sounder will produce an open zone tone and the fault will be displayed. Either re-enter your code to turn off and investigate or omit the faulty zone(s) from the system. Operating instructions How to unset the system (turn off) On entering the premises an entry beep tone comes on. Enter your code, the green indicator is lit. The system is unset and disarmed. Entry beep n n n n o/p ARC Unset output How to set program, or The green indicator should be showing. Prog n n n n Exit beep Or Exit beep ZONE - o/p ARC Set output Exit beep 0 seconds insistent beeps Enter your code number and the exit beep tone will start. Press the Prog key and the exit tone will stop. Press, or for the required program, the sounder will beep to acknowledge the program number. The exit beep tone will start and you should leave by the approved route. The system will Set as the beep tone stops. It is important that you follow the correct procedure when setting the system. After leaving the protected area it is absolutely essential that you wait until the exit tone stops, before assuming the system has set. How to set the system (on program ) PI issue _/0
32 How to Quick set Operating instructions How to Quick set During the exit period (on entering User code) the system may be Set Set the system or quickly by pressing Set. Set a Program This removes the exit time period. Set seconds insistent beeps o/p ARC Set output If you omit zones and require Quick Set, you will need to press Set twice. How to Omit zone(s) on setting system During the exit period after entering User code and selecting a program press Set the system or Set a Program and while the OMIT, the exit tone system is setting: will stop and zones that are about to be Omit ZONE(S) TO BE ARMED Exit beep armed will be displayed. Key in the zone number(s) n Press the zone(s) to be omitted which to be omitted will flash to confirm ZONE(S) TO BE OMITTED selection. Zone indicators which Set show steady are still about to be armed. Exit beep 0 seconds insistent beeps When the selection is complete press o/p ARC Set and the exit tone Set output will start. If a zone refuses to be omitted, it may be because the engineer has programmed the panel to prevent you from turning off the zone. If in doubt ask your installer for advice. Fire Alarm The fire zone will operate on detection of a fire, whether the system is Set or Unset, when configured as a hour zone, and cause a distinctive internal sounder tone. The external sounders will pulse on and off at second intervals and all keypad indicators will flash to attract attention. Accenta/Optima G Intruder system How to set Chime Zones Press number button to select / deselect Zone Chime Example: To set zone and to chime, Press: Chime Timeout after seconds if Chime no selection is made 0 8 Chime Deselect all zones (Factory default - no chime) Zone Zone Zone Zone Zone Zone Zone Zone 8 Appropriate Zone indicator is lit to show chime zone(s) Leave chime mode Zone n Chime selected Zone n Chime deselected Chime is a low security monitoring system for use when the system is Unset. When a zone that is set to chime is operated, the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show. The indicator may be cancelled by pressing. Chime is particularly useful in a shop to warn of a customer presence or in a house to warn that a door or particular area has been accessed. Any zone may set to be on or off chime by pressing the CHIME key and then keying in the required zone number(s). Key 0 to cancel all zones from chime. After a few seconds the system will automatically return to the mode. PI issue _/0
33 Accenta/Optima G intruder system Operator s Program mode The information below shows the programmable options available and how to change them. Once the programming mode has been accessed, each section may be changed in any order. As each operation is completed the system will automatically return to top level of program mode. Note: When programming the system should be in the mode, with the and Power indicators lit. To exit operation at any time On pressing the key you will quit the current level of operation. Quit the current function Leave Engineering menu Down one menu level How to enter Operator s program mode To enter the Operator s program mode the Prog system should be in mode with the and Power indicator lit. ZONE-8 Momentarily On 0 Operating instructions How to view the event log The panel can hold up to 8 previous events which can be scrolled automatically or manually. The automatic scroll starts with the newest event ( number 8) to the oldest one ( number ). Example: To view up to 8 previous events and thereafter to stop the event scroll, Press: Prog 0 Chime Enter Operator s program mode Chime View the event log Automatic event scroll Starting from event to 8 To manually scroll View event (oldest event) View event 8 Chime View event View event View event View event View event View event 8 (Newest event) Resume automatic scroll Stop event scroll / view Leave program mode Zone, PA and indicators will be lit to show zone in alarm. Flashing indicates the first zone in alarm. indicates status of panel at the time of alarm Operator s Program mode PI issue _/0
34 How to create/omit User code Operating instructions How to create/omit User code User code which is usually considered to be Example: To create user code, Press: the Managers code has the Prog 0 authority to add, change or delete the user code. Enter Operator s program mode Change / omit User code (By user only) ZONE - n n n n New code NOTE - The sounder will produce a flat beep if code is rejected. Or Omit To omit the user code Rising beeps ZONE - Leave program mode How to change current user code You can change the current user or user Example: To change user code for security code from 0 to, Press: reason. Prog 0 8 Enter Operator s program mode Change the code of Current 8 user (either User or User ) Accenta/Optima G Intruder system How to create/change/omit the Duress code The Duress code is used in a hold up situation where there is pressure to Set or Unset the system. Entry of the code will allow the system to work normally but also generate a silent PA type alarm by operating the PA communicator output. The duress code in not preprogrammed and can be created. Example: To createduress, Press: Prog 0 Enter Operator s program mode Change / Omit the Duress Code (By user only) ZONE - n n n n New duress code Rising beeps ZONE - Leave program mode ZONE - n n n n Current user new code NOTE - The sounder will produce a flat beep if code is rejected. ZONE - NOTE - Factory default code for User is not programmed Rising beeps Leave program mode PI issue _/0
35 Accenta/Optima G intruder system Operating instructions How to carry out Alarm and Walk tests The alarm test function allows you to test the Strobe, Bell, Low and high volume sounders of the system. Example: To start bell test and thereafter to stop bell test. Prog Enter Operator s program mode 0 Alarm test Press zero to turn off options,, and before selecting a new one The walk test function allows each detector to be checked in order to verify that they are functioning correctly. Servicing organisation details Servicing organisation name: Strobe test Bell test Low volume sounder High volume sounder Walk test Bell on Strobe On internal low volume sound internal high volume sound Strobe x for zone x for zone x for zone flat x for zone flat x for zone flat x for zone 8 Rapid for PA Rapid for Strobe On Appropriate zone lights are lit(latched) Zones 0 OFF Exit current level Leave program mode Bell Time: Bell delay How to carry out Alarm and Walk tests Telephone number: Area protected Program Program Program Date of installation: Zone Zone Account Number: Zone Zone Installation Date: Zone Zone Zone Zone 8 T = Timed (Entry/Exit - Zone) TI = Time Inhibited (Access zone to keypad) I = Immediate (All zones armed to give full alarm) PI issue _/0
36 Operating instructions Quick Reference Accenta/Optima G Intruder system To Alarm state n n n n Bell Alarm FIRST ZONE IN ALARM OTHER ZONES IN ALARM To Omit zones on Setting system Omit Set the system or Set a Program and while the system is setting: ZONE(S) TO BE ARMED Investigate the Alarm ALL ZONE n Exit beep Press the zone(s) to be omitted Strobe Off ZONE(S) TO BE OMITTED Set To set Chime zone Exit beep Chime o/p 0 seconds insistent beeps Quick Reference ARC Set output 8 Zone to chime Normal indications of an Unset system Power Alarm indications Bell On Strobe Alarm To Set the system (Program ) n o/p n n n Exit beep 0seconds insistent beeps ARC Set output To Set a Program n n n n Prog Exit beep Or o/p Exit beep ZONE - Exit beep ARC Set output 0 seconds insistent beeps To Un-set the system n n n n o/p Entry beep ARC Unset output To Quick Set the system Set the system or Set a Program Set o/p seconds insistent beeps ARC Set output Operator s program mode menu map To exit Operator s program mode Prog n n n n Operator s Progam Mode Change / omit User code (By user only) Leave program mode Change the code of Current user (either User or User ) n n n n New code Omit To omit the user code 8 Alarm test 0 n n n n Change / Omit the Duress Code (By user only) n n n n Quit the current function Leave program menu Down one menu level Chime View the event log Automatic event scroll Starting from event to 8 For manual scroll 8 View event (oldest event) View event 8 (Newest event) automatic scroll 0 Strobe test Bell test Low volume sounder High volume sounder Walk test Chime Resume Press zero to turn off options,, and before selecting a new one Exit current level Leave program mode Chime Leave program mode Leave program mode Stop event scroll / view Leave program mode The panels conform to the requirements of the European EMC and Low Voltage directives, and carries the CE mark 8 PI issue _/0
Intruder alarm system Engineering Information
ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE Chime Omit Chime Omit Prog Prog Set Set PA PA Chime Omit Prog Chime Omit Set PA Prog Set PA Intruder alarm system Engineering Information 0 6 7 8 6 7 8 9 0 6 7 8
How To Set A Timer On A Gg System
ZONE ZONE 2 ZONE ZONE ZONE 5 ZONE 6 ZONE 7 ZONE Power PA XR2/ XR2+ Intruder alarm system Operating Instructions ZONE ZONE 2 ZONE ZONE ZONE 5 ZONE 6 ZONE 7 ZONE 0 2 5 6 7 9 Omit Prog Remote LED keypad 0
XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication
h m mi R s t P o S t A XR EP 9 XR G panel with built-in keypad 2 5 6 7 Power A tack 0 2 5 6 7 9 Intruder alarm system Operating Instructions These operating instructions cover the following intruder system:
2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack
Access codes Contents Unset system indications - - - - - - - - - - - System indication - - - - - - - - - - - - Access codes - - - - - - - - - - - - - - - - How to operate Personal - - - - - - How to unset
Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.
Reset Chime Omit Prog Set Power PA Day ZONE PA PA Accenta/Optima Engineer s Manual Power Gen" ACCENTA! " # $ % & Zones Power Attack Tamper Day 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set Accenta/! mini
Intruder alarm system Operating Instructions
New remote keypad Intruder alarm system Operating Instructions 0 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Power Power 0 2 3 5 6 7 8 Chime Omit Prog 4 9 Set AccentaG3 mini Servicing organisation details
9452/9453 Installation and User Guide
9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and
Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security
Accenta/Optima User Guide ZONE 1 2 3 4 5 6 7 8 9 Chime Omit Prog PA 0 1 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Accenta + TA PA DAY POWER PA! " # $ % & 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set PA
TS510 & TS500. Installation & User Guide. Compatible Equipment
Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500 Overview Introduction
CONTENTS 4. HOW TO UNSET THE PANEL...7
Pi-8 USER MANUAL CONTENTS 1. THE KEYPAD AND ITS OPERATION...3 1.1 DESCRIPTION OF THE KEYPAD LEDS... 3 1.1.1 READY LED (RED)...3 1.1.2 TAMPER LED (RED)...3 1.1.3 POWER LED (GREEN)...3 1.1.4 CIRCUIT LEDs
500r+ Installation and User Guide
500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and
Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications
Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection
9448 Installation and User Guide
9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6 9448 INTRODUCTION The 9448 is a 3 zone control panel with separate Entry/Exit and
SECURIT 800L+ CONTROL PANEL
USER MANUAL SECURIT 800L+ CONTROL PANEL COMPANY PROFILE IntelliSense have been successfully making security products for over 20 years and lead the security industry throughout the world with many innovative
ACTIVE 5 ENGINEERING MANUAL
ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features
TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC
TS590 Intruder Alarm Control Panel 7:0 0 Jan _ ~ A B 5 6 C 7 8 9 D 0 ESC Setting the System Enter your passcode XXXX then leave the protected area. Unsetting the System Go directly to the keypad and en
HARDWIRED CONTROL PANELS
USER GUIDE 9651 HARDWIRED CONTROL PANELS Contents 1. Introduction...3 The Alarm System...3 The Keypad...3 About This Guide...5 2. Everyday Operation...6 How Do I Know if the System is Working?...6 Setting
CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual
SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL
User s Information Guide R1A
HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes
Master User Guide Premier Elite 24/48/88/168/640
Master User Guide Premier Elite 24/48/88/168/640 INS177-7 Overview Premier Elite Series Master User Guide Contents 1. Overview... 4 Introduction... 4 Keypads... 6 Emergency Keys... 7 The Quick Arm Keys...
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels. Issue 12
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Security Control Panels Issue 12 Contents Veritas 8, 8C & R8 Installation Manual Contents 1. Quick Reference and Factory Settings... 3 Programming Guide...
USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT
USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT CONTENTS Page INTRODUCTION... 2 Security conditions... 3 Full Set (Fully armed)... 3 Part Set (Partially armed)... 3 Unset (Disarmed)...
IDS X-Series User Manual 700-398-01D Issued July 2012
1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...
SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL
SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL PINKERTON Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS...1 INSTALLATION OF THE SECURITY SYSTEM...2 COMMISSIONING
SECURIT 800L+ CONTROL PANEL
INSTALLATION MANUAL SECURIT 800L+ CONTROL PANEL With additional options CONTENTS Warnings 2 Standards 2 Warranty Statement 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor
EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1
Contents Introduction 1 Using EURO Panel with Code or Tag 7-9 Intelligent Setting 13 Silencing the Alarm 20 Setting Individual Areas 14-17 Chime Facility 22 Omitting Inputs 18-19 Keypad Hold Up/Personal
Users Guide to Keypad Functions
Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
Control/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
ACP10 10 Zone Intruder Alarm System
ACP10 10 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 4 Remote Keypads... 5 LED Remote Keypad... 5 LCD Remote Keypad... 5 USB-Link...
Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security
Accenta/Optima User Guide ZONE 1 2 3 4 5 6 7 8 9 Chime Omit Prog PA 0 1 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Accenta + TA PA DAY POWER PA! " # $ % & 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set PA
Security System User Guide
Security System User Guide Contents 1. Introduction... 1 Controls and Displays... 3 Displays... 3 Controls:... 4 2. Everyday Operation... 5 Access to the System... 5 Entering and Leaving the Protected
IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18
INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST
D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia s largest
USER GUIDE HARDWIRED CONTROL UNIT
USER GUIDE HARDWIRED CONTROL UNIT 1. Introduction...3 Alarm System...3 Keypad...4 Proximity Tags...4 Mains Power Failures...6 About this Guide...7 2. Everyday Operation...8 Setting the System...8 General
INSTALLATION MANUAL 5-051-719-00 CONTENTS
INSTALLATION MANUAL CHALLENGER VIII CONTROL PANEL 5-051-719-00 CONTENTS Warnings 2 Standards 2 Product Description 2 Available Parts 2 Intended use 2 Specifications 3 Processor Version 3 Power Supply 3
Solution-16 Operators Manual ISSUE 1.60
Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided
Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...
TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6
HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS
ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete
User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5
User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5 User Guide Summary User Guide Summary Full Set Press Full " Part Set Press Part Set Number # or $ Press Part % Unset Omit Zones Press Full or Part
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Master User Guide Premier Elite Series
Master User Guide Premier Elite Series INS177-8 Overview Premier Elite Series Master User Guide Contents 1. Overview... 5 Introduction... 5 Keypads... 7 Emergency Keys... 8 The Quick Arm Keys... 9 Keypad
NESS D16. 16 Zone Control Panel and Dialler OWNER S MANUAL
NESS D16 16 Zone Control Panel and Dialler OWNER S MANUAL REVISION 2, JULY 2001 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head Office only WWW.NESS.COM.AU Australia
Solution 862 Operators Manual. Issue 1.00
Solution 862 Operators Manual Issue 1.00 Solution 862 Operators Manual Copyright 1998 by Electronics Design and Manufacturing Pty Limited, SYDNEY, AUSTRALIA Document Part Number MA406O Document Issue
Speech Dialler Engineering Information
Speech Dialler Engineering Information Description The Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it triggers the Informa. The Informa uses
NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)
NetworX Series NX- 4/8 Code Pad User Manual (Australian Version) Table Of Contents Code Pad Diagram... Inside Front Glossary of Terms...2 Understanding the Code Pad lights...3 Code Pad Tones...4 Fully
MATRIX 6/816. Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7
MATRIX 6/816 Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7 CONTENTS 1. GENERAL OVERVIEW... 1 1.1 Keypad Buttons... 1 1.2 Keypad Display... 2 1.3 Common Keypad Indications...
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
User.QXD 09/05/00 14:47 Page 1 Gardtec 370 581/582 User Instructions
Gardtec 370 581/582 User Instructions Contents Introduction 1 Keypads 1 User Levels and Options 1 Master Code Flow Chart 3 Setting and Unsetting the System 4 Removing Zones and Setting the System 5 Testing
NetworX NX-6V2. LED Keypad User Manual
NetworX NX-6V2 LED Keypad User Manual POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
IMPORTANT USER INFORMATION
TM C P 8 L L C D U S E R M A N UA L TM Contents Introduction................................. 1 Display Status Blanking........................ 2 IMPORTANT USER INFORMATION.............. 2 Full Setting
Programming & Installation PIEZO WARNING. EN50131-3 : 2009 EN50131-6 : 2008 EN50131-5-3 : 2005 Security Grade 2 Environmental Class II RINS1347-2
Programming & Installation EN50131-3 : 2009 EN50131-6 : 2008 EN50131-5-3 : 2005 Security Grade 2 Environmental Class II PIEZO WARNING The Enforcer control panel contains a 100 dba siren, please be aware
SECURITY SYSTEM NOTES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function This system is is not partitioned. EMERGENCY ACTIVATION KEYS
Diamond + User Manual. Wireless Alarm System. Default codes: User code: 1234 Master Manager Code: 2222
Diamond + Wireless Alarm System User Manual Default codes: User code: 1234 Master Manager Code: 2222 CONTENTS CHAPTER 1: INTRODUCTION... 4 CHAPTER 2: KEYPADS / READERS... 5 CHAPTER 3: THE KEY-FOB... 6
SECURITY SYSTEM NOTES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary
ICP-CP500. User's Guide ICP-CP500 Codepads
ICP-CP500 EN User's Guide ICP-CP500 Codepads ICP-CP500 User's Guide 1.0 ICP-CP500 Series Codepads Overview EN 2 1.0 ICP-CP500 Series Codepads Overview The codepad is the communications interface between
9x5x PROGRAMMING GUIDE
9x5x PROGRAMMING GUIDE HARDWIRED CONTROL UNITS 9853, 9752, 9751 Hardwired Control Unit Programming Guide This document applies to control panels using software version 4.2.x. Cooper Security Ltd. 2005
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
Solution 880 Operators Manual ISSUE 1.10
Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA408O DOCUMENT ISSUE 1.10 Printed 25 May 2001 This documentation is provided
Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS915-2. EN50131-1 Security Grade 2 Environmental Class 2
Matrix 424/832/832+ ICON & LCD User Manual Software Version 5 RINS915-2 EN50131-1 Security Grade 2 Environmental Class 2 CONTENTS CHAPTER 1: INTRODUCTION... 1 CHAPTER 2: REPLACING THE BATTERIES... 2 CHAPTER
Galaxy 2 Series. User Guide. Honeywell Security
Galaxy 2 Series User Guide Honeywell Security Table of Contents Table of Contents... iii Introduction...1 Controlling Your Alarm System...2 Users... 2 Groups... 2 Keypads...3 Prox Tags/Cards... 3 Wireless
User Manual Wireless Alarm System RINS1548-4. PIEZO WARNING The wireless system contains a loud siren, please be aware of this after an activation
EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008 PD6662:2010 Security Grade 2 Environmental Class II Software Version >9.13 User Manual Wireless Alarm System RINS1548-4 PIEZO
Security System. User's Guide. Keypad
Security System EN User's Guide Keypad Security System User's Guide This system includes a telephone line seizure feature. The system can be programmed to communicate with a central monitoring station
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
astec Integrated Alarm System USER GUIDE
astec Integrated Alarm System USER GUIDE 020008599 CONTENTS Full Set, Part Set and Disarm 3 Instant Full Set 3 Part Set with exit time 4 Bell Test 4 Bypassing zones 4 Switch Lights on/off 4 Bypass (24
616, 626, 636 & 646 Keypads
616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15
i 70 Installation Manual V1.04 Contents Grade 2 Wireless Intruder Alarm System YOUR SECURITY IS OUR PRIORITY Installation Instructions 2
YOUR SECURITY IS OUR PRIORITY Contents Installation Instructions 2 Operation Instructions Trouble shooting Technical Specification 8 25 31 i 70 Grade 2 Wireless Intruder Alarm System Global Security Devices
National Security Systems Inc (800)457-1999. Security System User's Guide
National Security Systems Inc (800)457-1999 Security System User's Guide Security System Glossary As security system technology has evolved, a special jargon has developed. Some terms widely used within
Vision Security System OWNER MANUAL V-LCD1
Vision Security System OWNER MANUAL V-LCD1 Congratulations on your purchase of the OPTEX Vision security system. Vision is an advanced microprocessor based alarm system which provides fire and burglar
NetworX Series. NX-148E LCD Keypad. User Manual
NetworX Series NX-148E LCD Keypad User Manual TABLE OF CONTENTS I. GLOSSARY OF TERMS... 3 II. UNDERSTANDING THE LIGHTS... 4 III. KEYPAD FUNCTIONS... 5 ARMING YOUR SYSTEM IN THE AWAY MODE... 5 MAKING YOUR
Speech Dialler Engineering Information
Speech Dialler Engineering Information Description The ADE Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it will trigger the Informa. The Informa
S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY. SIERRA Page 1
S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY SIERRA Page 1 C O N T E N T S USING YOUR SIERRA SYSTEM: Turning On/Off Home Arming Instant Home Arming Quick Exit Mode Chime Mode SPECIAL FUNCTIONS:
THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL. Security Control Panels with Integrated Communicator. Issue 6
THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL Security Control Panels with Integrated Communicator Issue Contents Premier 4// Master User Manual Contents. About the System... Introduction... About this
CS450. User Manual 143163999-2
CS450 User Manual 143163999-2 COPYRIGHT SLC BV 1997. All rights reserved. No part of this publication may be reproduced, transmitted, stored in a retrieval system, or transmitted in any form, or by any
What is an intruder alarm?
How to Plan and install an Intruder Alarm PART 1 PART 1 August 009 What is an intruder alarm? An intruder alarm system monitors and detects unauthorised entry to properties homes and businesses alike -
Microprocessor Home Security System
numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a
User Guide Premier Elite 24/48/88/168/640
User Guide Premier Elite 24/48/88/168/640 INS221-4 Overview Introduction Users of the alarm system will be assigned a unique 4, 5 or 6 digit User code, and may be assigned a Proximity Tag. User codes are
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM Page 0 Table of Contents Introduction 1 System Basics.. 1 Burglary Protection.. 1 Fire Protection.. 1 Security Codes. 1 Zones and Partitions
www.sebury.com.cn Digital Keypad Use s Manual
K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4
SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Installation Date / / Central Station Duress Code EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary Emergency Police PROGRAMMED
SCORPION. micron security products
SCORPION 4120 6020 & 8020 USER INSTRUCTIONS Thank you for purchasing a Quality Micron Security Alarm Controller. Micron product is manufactured to exacting quality standards. We understand the importance
PA4. 4 Zone Wired Intruder Alarm System. Installation & Operating Manual. MAINS CLEAR 24Hr. Zone 1 Zone 2 Zone 3 Zone 4
PA4 4 Zone Wired Intruder Alarm System MAINS CLEAR 24Hr Zone 1 Zone 2 Zone 3 Zone 4 1 2 3 4 5 6 7 8 9 OMIT AWAY 0 ER HOME EXIT 1. Check all windows and doors are closed. 2. a) Fullguard - 'Away' then 'Arm'.
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
D1260/D1260B. Keypad. National Security Systems Inc (800)457-1999. Owner's Manual
D1260/D1260B EN Owner's Manual Keypad National Security Systems Inc (800)457-1999 D1260/D1260B Owner's Manual This system includes a telephone line seizure feature. The system may be programmed to communicate
User Manual. Wireless Alarm System. PIEZO WARNING: This wireless alarm system contains a 100dBA siren, please be aware of this after activation.
User Manual Wireless Alarm System PIEZO WARNING: This wireless alarm system contains a 100dBA siren, please be aware of this after activation. EN50131-1:2006+A1:2009 EN50131-3:2009 EN50131-6:2008 EN50131-5-3:2005+A1:2008
VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security Systems with Scheduling
VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security Systems with Scheduling User Guide K0377V2 7/09 Rev. C 2 TABLE OF CONTENTS SYSTEM OVERVIEW... 5 General... 5 A Partitioned System...
EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual
EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: [email protected]
Reference & Installation Manual
& Versions 4.4 (728ULT) & 4.1 (738ULT) 728ULT 738ULT Reference & Installation Manual Table of Contents Introduction... 1 About This Manual... 1 New Features... 1 Main Features... 1 Specifications... 1
INSTALLATION MANUAL PC2525. Version 1.1
INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...
Using Your. Security System With Icon Keypad S5020, S5021, S5022
Using Your Security System With Icon Keypad S5020, S5021, S5022 Contents 1 Overview Your Security System... 1 How Your Security System Works... 2 Your System's Programming... 3 Getting Used to Your System...
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide
HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-5587722 +972-3-5500442 [email protected] http://www.pima-alarms.com
ICP-CC488. Installation Guide ICP-CC488 Control Panel
ICP-CC488 EN Installation Guide ICP-CC488 Control Panel ICP-CC488 Installation Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems,
D200+ Auto-Dialler Installation/Operators Manual
D200+ Auto-Dialler Installation/Operators Manual Bell System (Telephones) Ltd. Presley Way, Crownhill, Milton Keynes, MK8 0ET D200+ Software Version 1.0 Contents General Description...3 Central Station
Destiny 4100. Destiny 4100. Owners Manual
Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6
VR8. User Guide Intruder Alarm System
VR8 EN User Guide Intruder Alarm System VR8 User Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights
tattletale User Guide Consumer unit version 2.48 1 P a g e
tattletale User Guide Consumer unit version 2.48 1 P a g e Contents Basic 1... 4 Base Unit Features... 4 Initial Setup... 4 Arming... 5 Disarming... 5 Quiet Button... 5 Settings... 5 Settings 2... 6 Quick
ALARM SYSTEM USER GUIDE
ALARM SYSTEM USER GUIDE 1. Introduction...3 Alarm System...3 Keypad...4 Proximity Tags...4 723r Telecommand/ 722r PA...7 Mains Power Failures...7 About this Guide...8 2. Everyday Operation...9 Setting
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
SCORPION Z16040C Alarm Controller User Instructions
SCORPION Z16040C Alarm Controller User Instructions Thank you for choosing to purchase this micron security alarm controller. Micron product is manufactured to exacting quality standards. We understand