PITOT-STATIC TUBE OR PITOT TUBE FOR MEASURING FLOW RATES?
|
|
|
- Wesley Oliver
- 9 years ago
- Views:
Transcription
1 XVII IMEKO World Congress Metrology in the 3rd Millennium June 22 27, 2003, Dubrovnik, Croatia PITOT-STATIC TUBE OR PITOT TUBE FOR MEASURING FLOW RATES? Eddy Jacques, Pierre Wauters Department of Mechanical Engineering, Université Catholique de Louvain, Louvain-la-Neuve, Belgium Abstract Where volume flow rates in ventilation applications are to be measured common practise is to integrate the velocity profile over the entire cross-section. One of the instruments used to carry out the flow velocity traverse is the Pitot-static tube. The paper examines, on an experimental basis, whether the readings of both total and static pressure by a Pitot-static tube could not validly be carried out by a combination of a Pitot tube that measures the total pressure and tappings at the wall of the duct where the static pressure is picked up. The advantage becomes particularly interesting for applications where the flow rate may change in time. Keywords: flow rate, Pitot tube, Pitot-static tube. 1. INTRODUCTION A lot of ventilation applications entail substantial energy costs. Fact is that many of these applications do not require continuously the full ventilation capacity for which the fan system has been designed. Many of these ventilation systems would be more economically operated if the fan performance were to match more closely the real but minimum volume or pressure requirements. Different volume flow rates can be supplied either by a fan with variable rotational speed or variable blade angle setting or by a multiple fan system where fans are operating in parallel. Equipping these fans with a regulator is not a major technical challenge. But, the real difficulty is the correct measurement of the control variable that is the actual flow output. If the ventilation circuit or network connected to a single fan is fully passive, i.e. the overall hydraulic resistance of the circuit is constant and well known, the volume flow rate produced by the fan can be reasonably well determined by measuring either its rotational speed or its blade angle setting. In this particular case an appropriate calibration suffices to determine the relationship that exists between volume flow rate and rotational speed or blade angle setting. But, for multiple fan systems and/or ventilation circuits that have regulators, the aforementioned relationship can no longer be determined. Indeed, the duty point of any fan in a network may move along its characteristic curve, and thus entail a different value of the flow rate, even though its rotational speed or pitch angle did not change, and vice versa. Here one needs to measure directly the real volume flow produced by the fan. This measurement can only be achieved if there is an appropriate airway section available upstream or downstream of the fan where the flow pattern is supposed to be steady and fully developed. Optimal would be, of course, an airway with a standardised section. Unfortunately, industrial site installations have their own constraints and often it is unlikely that such a standardised section is available or could be built in. Because the velocity varies from point to point over the cross-section of the airway, integral methods using orifice plates or gas tracing should be preferred. But, gas tracing is a one-off and delicate method to operate while the use of an orifice plate is costly in energy consumption and, therefore, often not taken into consideration. The only practical solution available is to determine the flow rate from an unbiased averaged air velocity value. Enough readings of the velocity component and its direction need then to be recorded. With this velocity profile pattern and an adequate integration technique, one may be able to determine the fluid volume flow rate with an acceptable accuracy. Obviously, the number of measurement points has to be all the more important that the velocity profile is distorted. The integration calculation is largely simplified if the distribution of the measurement points in the concerned cross-section follows certain rules. As long as the flow pattern stays steady, these measurement points may be sequentially accessed with only one instrument that follows a predefined traversing path [1]. Usually the measurements are carried out either with a Pitotstatic tube or with an anemometer. But, in changeable flow conditions all the points should ideally be measured simultaneously, or at least, within a time span that is much shorter than the time between two changes of the duty point of the fan. Moreover, most site applications do probably not provide an easy access to the measurement section that has been chosen for this purpose. Convenient would then be to install permanently a certain number n of instruments in parallel. If these instruments are Pitot-static tubes, their entire set up would be expensive. Replacing them by a bunch of tubes, fashioned as Pitot tubes would be a more economical solution, provided that the static pressure could be measured elsewhere. If the static pressure were uniformly distributed over the entire cross-section, a straightforward solution would be to pick it up at the wall of the duct. This solution, if only to simplify the entire set up, would also reduce the number of hoses that transmit the pressure information to a local manometer, n+1 instead of 2n. If n is large, the gain is worthwhile.
2 The approach of substituting the static pressure of the Pitot-static tube by the static pressure measured at the wall, has been discussed in literature [2] and corrections are given for fully developed flows in pipes. But there seems to be no experimental evidence of whether this method could be applied or need to be encouraged in practical cases. The following question is certainly not without interest : what would be the loss or maybe the gain in accuracy on the ultimate value of the flow rate if this new approach were to replace the recommended method with the Pitot-static tube? 2. PROBLEM STATEMENT In turbulent flow the time-averaged static pressure varies with the distance from the wall of the pipe. According to Goldstein, the radial variation of the static pressure is given by the equation : '2 '2 R '2 w v pstat = pw ρ v ρ dr, (1) r r where u', v' and w' are the r.m.s. values of the velocity fluctuations in the axial, radial and tangential directions respectively, p w the static pressure recorded by the hole in the wall, ρ the fluid density and R the pipe radius. Starting from this datum, it is obvious that the static pressure is not uniform across the entire cross-section and must be maximum at the wall since v' and w' are zero. It is less obvious how this static pressure is sensed by the traversing Pitot-static tube. Studies focussed on this particular aspect [2] propose corrections to be applied to the reading of the total-pressure sensed by the Pitot-static tube. But, because the turbulence intensity is mostly unknown, it seems useful from a practical point of view to evaluate experimentally the margin of error that may exist on the ultimate result of the flow rate. 3. OBJECTIVE OF THE WORK The objective of this experimental work is not to confirm the theory, but to examine in how far this approach is applicable for measuring the flow rate in most industrial ventilation systems and particularly for the ones where volume flows are due to change. At this point it should be noted that the study does not replace a multiple point method such as the log-tchebycheff by a new one. It aims only to simplify the instrumentation. Surprisingly, this approach seems never to have been taken into consideration in ISO-norm context. 4. FACILITY SET-UP A schematic top-view of the test facility is given in figure 1. A series of ducts with diameter of.8 m forms an open loop circuit with a bell-mouth shape piece at its inlet side. Variable volume flows are produced by adjusting the rotational speed of the ducted centrifugal fan that is driven by a voltage controlled DC motor. The test section is located at the inlet side of the fan, approximately at 3D from the circuit entry. An orifice plate has been installed in the fan downstream section at approximately 5.5D from the outlet of the duct, so ensuring an airway that meets the ISO standards of length of more than 20D [3]. 5. INSTRUMENTATION The measurement instrumentation is basically made up by a movable Pitot-static tube, a differential pressure transducer in the range up to 3 kpa and a digital data acquisition system and a processing unit. A multiplexing system set up by eight electronic valves mounted in parallel allows the experimenter to connect the first portal of the pressure transducer to either one out of eight possible input pressure signals. The second portal picks up the ambient pressure so that all the measured pressures are in fact differential values with respect to the same reference value. The calibrated electrical output signal of the transducer is directly displayed on an voltmeter and is at the same time recorded on a PC equipped with a data acquisition board. Appropriate A/D conversions and data filtering are achieved by LABVIEW software so to output measured values at a rate of ten per second.
3 6. METHODOLOGY The experimental work is seen to be carried out in two major steps. During the first time, the experimenters aim only at observing how the static pressure measured by a Pitot-static tube would behave versus the one measured at the wall. Of interest here are not only the results in cases of well developed flow patterns, but also those where the flow pattern is or has been distorted. It should be clear that in this context there is no need to carry out a velocity traverse according to a log-tchebycheff scheme, nor is there any care about measuring the air volume rate. Therefore, this kind of investigation needs only the Pitot-static tube to be moved equidistantly along, for example, two diagonals. The second step involves the tests that focus mainly on the flow rate determination. In this case, obviously, the Pitot and wall measurements are taken at best in the inlet duct of the fan i.e. where the flow is most likely to be steady and reasonably well developed. Nevertheless, for the sake of having a so-called reference value of the flow rate, a standardised orifice plate is additionally installed in the test circuit. Now, the locations to which the Pitot-static tube is moved matter and, therefore, follow the recommendations of the ISO standard according to a log-tchebycheff scheme [4]. Various air flow rates are explored by changing the rotational fan speed. 7. EXPERIMENTS AND RESULTS For all concerned tests, eight measured pressure signals are sequentially recorded : four independent gauge pressures at four wall tappings, one static and one total pressure picked up by the Pitot-static tube and two averaged pressure related to the orifice plate. Where the comparison between the two independently measured values of the static pressure is concerned, one may observe that virtually all twenty-one tests show similar results, i.e. the static pressure picked up by the Pitot-static tube shows a slightly lower value than the one measured at the wall of the duct. For tests where the flow conditions are virtually not disturbed, the difference between the two averaged values stays generally below 5. For slightly disturbed flows this difference may go up to 10. Where the proper flow rate measurements are concerned, a cross-section close to the inlet of the fan is investigated (see figure 1). The measurement programme is achieved according the following scheme : the Pitot-static tube is moved manually along one diameter of the cross-section to each of the seven predefined r/r locations. At each of these locations the data acquisition system reads the two Pitot values, the four independent static pressure values at the wall and the two averaged pressure values related to the orifice plate. This measurement procedure is then repeated for a second traverse along a new diagonal that is perpendicular to the first one. Although it should be discouraged, a few limited tests are nevertheless carried out at a cross-section downstream of the fan. In this case, despite the installation of an "etoile" flow straightener at 2D upstream, the velocity profile stayed disturbed as can be seen on figure 2 where the profile is pictured by the total pressure curve. This figure displays in fact three sets of dots that are respectively the total and static pressure, both measured by the Pitot-static tube and the static pressure at the wall. All dots are plotted versus the Pressure (Pa) Figure 2. Pressure profiles downstream of "etoile" flow straightener Static pressure at wall Total pressure Static pressure at Pitot
4 Pressure (Pa) T3 / W T2 / W T1 / W T4 / W T3 / P T2 / P T1 / P T4 / P Figure 3. Pressure values for Tests 1, 2, 3 & 4 along Diameter 1 locations of the Pitot-static tube. The test conditions in this case are characterised by a Reynolds number of around 808,000 that corresponds to a volume flow of 7.5. After testing a second and smaller flow rate (5 ), there is no point in going on with measurements in this downstream cross-section because the velocity profile does not match the normal profile for which a Tchebycheff traversing method may be applied. Let it be noted in passing that all four tests show similar results where the difference between Pitot and wall static pressure is concerned: the difference, rather small (.6 in case of figure 2), tends to stay constant over the cross-section. At the upstream side of the fan, four different volume flow rates are explored. Figure 3 plots the two average static pressure values for the four flow volumes as a function of the location of the Pitot-static tube. The double set of dots for D1 and D2 in figure 4 may give an idea of the corresponding velocity profiles during tests T1, T2, T3 and T4. The entire set of experimental results enables one to Velocity (m/s) Figure 4. Velocity profiles : Tests 1, 2, 3 & 4 ( D1& D2 ) D1 T3 D1 T2 D1 T1 D1 T4 D2 T3 D2 T2 D2 T1 D2 T4
5 observe that : - the static pressure at the wall stays very stable. The average value of the standard deviation of all measurements at the wall is around 1.2 Pa, ranging between.4 and 2.1 Pa ; - the static pressure picked up by the Pitot-static tube has also an almost constant value and the measurement scatter has a slightly lower but similar standard deviation, i.e. 1.1 Pa, ranging between.5 and 2.0 Pa ; - as expected, none of the static pressure at the wall shows a lower value than the one measured by the Pitot-static tube. From these results we may draw a first conclusion, i.e. a measurement of the static pressure at the wall provides a valid alternative value for the one obtained by the Pitotstatic tube if the flow is reasonably steady. This observation is all the more useful that the volume flow is proportional to the square of the pressure difference, so reducing the error by half. Where the final aim of these investigations are concerned, i.e. determination of the volume flow, table 1 shows interesting results. TABLE I. Volume flow calculations and mutual differences Test # (1) O.pl. (2) Pitot (3) Wall (1-2) (1-3) (2-3) T T T T The column marked (1) records the calculated volume flow rates by using the data related to the orifice plate according to the ISO formulas [3]. As previously mentioned, these results are considered here as a sort of reference values. The next column (2) corresponds to the flow rates calculated according to the Tchebycheff method ; all data involved are exclusively produced by the Pitot-static tube. The column (3) represents the results calculated in a similar manner as the second one, however the static "Pitotpressure" values being substituted by the ones of the static "wall-pressure". Columns five, six and seven show the mutual differences in percentage between the calculated flow rates for the tests listed in column one. Remarkable are that : - the Tchebycheff traversing method yields flow rate values that are systematically higher than the ones obtained by the orifice plate. Nevertheless, these results may be considered as being satisfactory since the expected error of an orifice plate method is already around 1.5 to 2 ; - substituting the static Pitot pressure by the one measured at the wall seems to reduce the error of overestimating the flow rate ; - the differences between the two columns related to the Tchebycheff method are less than.8 and, therefore, not to be considered as being significant. 8. CONCLUSION The experimental results show that the difference between the static pressure picked up by the Pitot-static tube and the static pressure measured at the wall is sufficiently small in order to allow one to have confidence in the calculated flow rates. This finding may open the way to a simplification of a standardised flow rate measurement method that is based on a velocity traverse with Pitot-static tubes. Likely it may also provide a solution to the difficult and not yet satisfactory solved problem of measuring flow rates in industrial ventilation applications where the duty points of one or more fans are due to change in time. Indeed, one could build a rather low cost equipment that is an assembly of ordinary Pitot tubes. This assembly being permanently installed in a well chosen section of the circuit, would yield the advantage of having an almost simultaneous measurement of the total pressure values at all predefined locations within one plane. The static pressure being measured at the wall would allow the velocity profile to be determined and hence, the volume flow rate to be calculated. From a theoretical point of view, the observed difference between both static pressure values is certainly an interesting aspect that needs further and thoroughly investigation. REFERENCES [1] G. Mbuyi Kamba, E. Jacques, & J. Patigny, "Contribution to the improvement of the log-tchebycheff multipoint integration technique for determining air flow rates", Proceedings of the XIII IMEKO World Congress, IMEKO, Torino, pp , [2] E. Ower & R. Pankhurst., "The Measurement of Air Flow", Pergamon Press, 363 pages,1977. [3] ISO 5167, "Measurement of fluid flow by means of differential pressure devices", [4] ISO 3966, "Measurement of fluid flow in closed conduits Velocity area method using Pitot static tubes", ACKNOWLEDGEMENT The authors express their gratitude to Roland Wanten for helping them to carry out the tests. Authors: Eddy Jacques, affiliation (Department of Mechanical Engineering, Université Catholique de Louvain, mail address (Place du Levant 2, B-1348 Louvain-la-Neuve, Belgium), phone ( ), fax ( ) and ([email protected]) ; Prof. Pierre Wauters, affiliation (Department of Mechanical Engineering, Université Catholique de Louvain, mail address (Place du Levant 2, B-1348 Louvain-la-Neuve, Belgium), phone ( ), fax ( ) and ([email protected]).
OPERATING FANS IN PARALLEL IN VIEW OF VARIABLE FLOW RATE OUTPUT
OPERATING FANS IN PARALLEL IN VIEW OF VARIABLE FLOW RATE OUTPUT Eddy J. Jacques & Pierre J. Wauters Department of Mechanical Engineering, Unité TERM, Université Catholique de Louvain, Belgium ABSTRACT
Averaging Pitot Tubes; Fact and Fiction
Averaging Pitot Tubes; Fact and Fiction Abstract An experimental investigation has been undertaken to elucidate effects of averaging stagnation pressures on estimated velocities for pressure averaging
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
FLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness
Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window
Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window Ahsan Iqbal #1, Alireza Afshari #2, Per Heiselberg *3, Anders Høj **4 # Energy and Environment, Danish Building Research
Experiment 3 Pipe Friction
EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional
Chapter 8: Flow in Pipes
Objectives 1. Have a deeper understanding of laminar and turbulent flow in pipes and the analysis of fully developed flow 2. Calculate the major and minor losses associated with pipe flow in piping networks
Lab 1a Wind Tunnel Testing Principles & Lift and Drag Coefficients on an Airfoil
Lab 1a Wind Tunnel Testing Principles & Lift and Drag Coefficients on an Airfoil OBJECTIVES - Calibrate the RPM/wind speed relation of the wind tunnel. - Measure the drag and lift coefficients of an airfoil
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22
BL_01 A thin flat plate 55 by 110 cm is immersed in a 6 m/s stream of SAE 10 oil at 20 C. Compute the total skin friction drag if the stream is parallel to (a) the long side and (b) the short side. D =
Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM
Force measurement Forces VECTORIAL ISSUES In classical mechanics, a force is defined as "an action capable of modifying the quantity of movement of a material point". Therefore, a force has the attributes
FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER
FLOW MEASUREMENT 200 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER Dr D G Stewart, NEL Dr M Reader-Harris, NEL Dr R J W Peters, McCrometer Inc INTRODUCTION The V-Cone
Accurate Air Flow Measurement in Electronics Cooling
Accurate Air Flow Measurement in Electronics Cooling Joachim Preiss, Raouf Ismail Cambridge AccuSense, Inc. E-mail: [email protected] Air is the most commonly used medium to remove heat from electronics
A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW. 1998 ASME Fluids Engineering Division Summer Meeting
TELEDYNE HASTINGS TECHNICAL PAPERS INSTRUMENTS A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW Proceedings of FEDSM 98: June -5, 998, Washington, DC FEDSM98 49 ABSTRACT The pressure
Characteristics of Centrifugal Blower and Its Effective Use in High Static Pressure Area
Characteristics of Centrifugal Blower and Its Effective Use in High Static Pressure Area Masayuki TAKAHASHI With small fans, selecting the right fan that most fits the purpose is extremely important from
Experiment # 3: Pipe Flow
ME 05 Mechanical Engineering Lab Page ME 05 Mechanical Engineering Laboratory Spring Quarter 00 Experiment # 3: Pipe Flow Objectives: a) Calibrate a pressure transducer and two different flowmeters (paddlewheel
A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS
A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS W. M. Torres, P. E. Umbehaun, D. A. Andrade and J. A. B. Souza Centro de Engenharia Nuclear Instituto de Pesquisas Energéticas e Nucleares
Testing methods applicable to refrigeration components and systems
Testing methods applicable to refrigeration components and systems Sylvain Quoilin (1)*, Cristian Cuevas (2), Vladut Teodorese (1), Vincent Lemort (1), Jules Hannay (1) and Jean Lebrun (1) (1) University
FAN PROTECTION AGAINST STALLING PHENOMENON
FAN PROTECTION AGAINST STALLING PHENOMENON Roberto Arias Álvarez 1 Javier Fernández López 2 2 1 ZITRON Technical Director [email protected] ZITRON Technical Pre Sales Management [email protected]
Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers
Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic
Flue gas measurement and control Partial-insertion pitot tubes in CEMS applications
Article AT/FLOW/002 EN Flue gas measurement and control Partial-insertion pitot tubes in CEMS applications Measurement made easy Specifying the most appropriate pitot flowmeter design in stack applications
SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER
SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER DEVELOPMENT OF AN AERODYNAMIC DEDUSTER FOR LIVESTOCK BUILDINGS G.A. Zhao, Y. Zhang Summary Dust is among the major pollutants that have a detrimental
ENGINEERING DATA. Fan Performance Troubleshooting Guide
Information and Recommendations for the Engineer ENGINEERING DATA Aerovent TC Ventco Fiber-Aire Twin City Fan & Blower TC Axial Clarage Fan Performance Troubleshooting Guide ED- Introduction Trying to
Flow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS
A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS Joseph J. Stupak Jr, Oersted Technology Tualatin, Oregon (reprinted from IMCSD 24th Annual Proceedings 1995) ABSTRACT The
A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER
A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER P. NAVA, M.PROFETI, M. GIACHI, F.SARRI GE-NUOVO PIGNONE G.P.MANFRIDA UNIVERSITY OF FLORENCE Italia Presented
Fan Basics and Selection Criteria (How to Use)
Feature: Understanding SANYO DENKI Products from Scratch Fan Basics and Selection Criteria (How to Use) Honami Osawa 1. Introduction In recent years, the importance of cooling technology has become even
Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation
Differential Relations for Fluid Flow In this approach, we apply our four basic conservation laws to an infinitesimally small control volume. The differential approach provides point by point details of
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 26 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
Understanding Pressure and Pressure Measurement
Freescale Semiconductor Application Note Rev 1, 05/2005 Understanding Pressure and Pressure Measurement by: David Heeley Sensor Products Division, Phoenix, Arizona INTRODUCTION Fluid systems, pressure
Air Flow Measurements
ME-EM 30 ENERGY LABORATORY Air Flow Measurements Pitot Static Tube A slender tube aligned with the flow can measure local velocity by means of pressure differences. It has sidewall holes to measure the
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
DESIGN CRITERIA AND OPERATIONAL LIMITS FOR AXIAL FLOW FANS OPERATED IN PARALLEL MODE
- 90 - DESIGN CRITERIA AND OPERATIONAL LIMITS FOR AXIAL FLOW FANS OPERATED IN PARALLEL MODE Dr.-Ing. Schiller, F. Howden Ventilatoren GmbH, Heidenheim ABSTRACT Axial Flow Fans are the preferred fan types
Physics 221 Experiment 5: Magnetic Fields
Physics 221 Experiment 5: Magnetic Fields August 25, 2007 ntroduction This experiment will examine the properties of magnetic fields. Magnetic fields can be created in a variety of ways, and are also found
Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics
Lecture 6 - Boundary Conditions Applied Computational Fluid Dynamics Instructor: André Bakker http://www.bakker.org André Bakker (2002-2006) Fluent Inc. (2002) 1 Outline Overview. Inlet and outlet boundaries.
Fluid Flow Instrumentation
Fluid Flow Instrumentation In the physical world, mechanical engineers are frequently required to monitor or control the flow of various fluids through pipes, ducts and assorted vessels. This fluid can
Air Conditioning Clinic
Air Conditioning Clinic Air Conditioning Fans One of the Equipment Series February 2012 TRG-TRC013-EN Air Conditioning Fans One of the Equipment Series A publication of Trane Preface Air Conditioning
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
Unsteady Pressure Measurements
Quite often the measurements of pressures has to be conducted in unsteady conditions. Typical cases are those of -the measurement of time-varying pressure (with periodic oscillations or step changes) -the
Flow Measurement in Pipes and Ducts. Flow Measurement in Pipes and Ducts, Course #503. Presented by:
Flow Measurement in Pipes and Ducts, Course #503 Presented by: PDH Enterprises, LLC PO Box 942 Morrisville, NC 27560 www.pdhsite.com This course is about measurement of the flow rate of a fluid flowing
Experiment (13): Flow channel
Introduction: An open channel is a duct in which the liquid flows with a free surface exposed to atmospheric pressure. Along the length of the duct, the pressure at the surface is therefore constant and
Flow System Calibration in Medical and Bio-medical Production Processes.
Flow System Calibration in Medical and Bio-medical Production Processes. Speaker / Author: Mark Finch Fluke Calibration Norfolk, Norwich, NR6 6JB, UK e-mail: [email protected] Phone: + 44 (0)1908 678
VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications
VOLU-probe/SS Stainless Steel Pitot Airflow Traverse Probes Accurate airflow measurement for demanding applications VOLU-probe/SS The VOLU-probe/SS Stainless Steel Pitot Airflow Traverse Probe is ideally
(Refer Slide Time 1:13 min)
Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras Module - 1 Lecture - 1 Introduction to the Study of Mechanical
Aids needed for demonstrations: viscous fluid (water), tubes (pipes), injections, paper, stopwatches, vessels,, weights
1 Viscous and turbulent flow Level: high school (16-17 years) hours (2 hours class teaching, 2 hours practical excercises) Content: 1. Viscous flow 2. Poiseuille s law 3. Passing from laminar to turbulent
ES250: Electrical Science. HW7: Energy Storage Elements
ES250: Electrical Science HW7: Energy Storage Elements Introduction This chapter introduces two more circuit elements, the capacitor and the inductor whose elements laws involve integration or differentiation;
EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE
EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE Vivek Khaire, Dr. Avijit Goswami Applied Thermal Technologies India 3rd Floor,C-Wing,Kapil Towers, Dr. Ambedkar Road, Pune- 411 1 Maharashtra,
Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.
Dimensional Analysis and Similarity Dimensional analysis is very useful for planning, presentation, and interpretation of experimental data. As discussed previously, most practical fluid mechanics problems
Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs
Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs Fan Performance (Paper I.D. 021) Mark Stevens Air Movement and Control Association International Abstract
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,
Lecture 14 Flow Measurement in Pipes I. Elbow Meters An elbow in a pipe can be used as a flow measuring device much in the same way as a venturi or orifice plate The head differential across the elbow
MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING
MATLAB AS A PROTOTYPING TOOL FOR HYDRONIC NETWORKS BALANCING J. Pekař, P. Trnka, V. Havlena* Abstract The objective of this note is to describe the prototyping stage of development of a system that is
ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts
ME 305 Fluid Mechanics I Part 8 Viscous Flow in Pipes and Ducts These presentations are prepared by Dr. Cüneyt Sert Mechanical Engineering Department Middle East Technical University Ankara, Turkey [email protected]
Rain Penetration Tests on Manthorpe Mini Castellated Vent Tile with 15" x 9" Format Roof Tiles. Prepared for: Ben Hales
Rain Penetration Tests on Manthorpe Mini Castellated Vent Tile with 15" x 9" Format Roof Tiles Prepared for: Ben Hales Manthorpe Building Products Ltd. 24 th June 2014 Report number 295-318 1 Rain Penetration
PNEUMATIC CONTROLS Selection and Description
PNEUMATIC CONTROLS Selection and Description Carnes pneumatic controlled throttling units are suitable for a standard 20 psi control system and may be supplied with pressure dependent or pressure independent
Centrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory
Physics 41, Winter 1998 Lab 1 - The Current Balance Theory Consider a point at a perpendicular distance d from a long straight wire carrying a current I as shown in figure 1. If the wire is very long compared
Optimum fin spacing for fan-cooled heat sinks
Optimum fin spacing for fan-cooled heat sinks Keywords: optimum fin spacing fan-cooled heat sink heatsink optimal fin pitch parallel plate fin array optimization forced air cooling fan curve pressure drop
Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.
COOLING FAN REQUIREMENTS CALCULATIONS Determining System Impedance Determining the actual airflow produced by a fan mounted in an enclosure is much more difficult than calculating the airflow required.
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As
du u U 0 U dy y b 0 b
BASIC CONCEPTS/DEFINITIONS OF FLUID MECHANICS (by Marios M. Fyrillas) 1. Density (πυκνότητα) Symbol: 3 Units of measure: kg / m Equation: m ( m mass, V volume) V. Pressure (πίεση) Alternative definition:
The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions
The Versatile Differential Pressure Transmitter By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter 2 Table of Contents Abstract... 3 Pressure Fundamentals... 3 Applications...
AMD-33 Air Measuring Station with VCD-33 Control Damper
Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES
ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES The purpose of this lab session is to experimentally investigate the relation between electric field lines of force and equipotential surfaces in two dimensions.
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT Kazuto Otakane, Tokyo Gas Co., Ltd Katsuhito Sakai, Tokyo Gas Co., Ltd Minoru Seto, Tokyo Gas Co., Ltd 1. INTRODUCTION Tokyo Gas s new gas meter,
Minor losses include head losses through/past hydrants, couplers, valves,
Lecture 10 Minor Losses & Pressure Requirements I. Minor Losses Minor (or fitting, or local ) hydraulic losses along pipes can often be estimated as a function of the velocity head of the water within
. Address the following issues in your solution:
CM 3110 COMSOL INSTRUCTIONS Faith Morrison and Maria Tafur Department of Chemical Engineering Michigan Technological University, Houghton, MI USA 22 November 2012 Zhichao Wang edits 21 November 2013 revised
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE
E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE References for Nuclear Magnetic Resonance 1. Slichter, Principles of Magnetic Resonance, Harper and Row, 1963. chapter
SUMMARY of PRODUCTS. HVAC Systems Control Airflow, Space, & Building Pressurization. Accurate airflow measurement for demanding applications
SUMMARY of PRODUCTS HVAC Systems Control Airflow, Space, & Building Pressurization Accurate airflow measurement for demanding applications Airflow Measuring Stations FAN-E AIRFLOW MEASURING STATION. The
Flow divider (flow distributor), type TQ
Flow divider (flow distributor), type TQ Pressure p max = 0 bar Flow Q CN max = 00 lpm Share ratio = :. General Task Flow dividers type TQ are self-regulating valves, which largely irrespective of the
Using meters to measure steam flow
Page 1 of 6 April 1998 Plant Engineering SELECTING NEW TECHNOLOGY: PROBLEM SOLVING Using meters to measure steam flow Jesse L. Yoder, Ph.D., Senior Analyst, Automation Research Corp., Dedham, MA Key Concepts
A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions
A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions by Laura Noelle Race An Engineering Project Submitted to the Graduate Faculty of Rensselaer
THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS
THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS Dr Andrew Pollard Principal Engineer GKN Technology UK INTRODUCTION There is a wide choice of flexible couplings for power transmission applications,
Smart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow
1 WATERFLUX - Comparisonon COO 2010-08-17. Rectangular Magmeter in water applications
1 WATERFLUX - Comparisonon COO 2010-08-17 Rectangular Magmeter in water applications Jef Neven KROHNE WATERMETERS $3000 EMF Price C&I (mechanical) water meters Residential water meters $30 Water Metering
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.
Fluid Statics When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid. Consider a small wedge of fluid at rest of size Δx, Δz, Δs
Open channel flow Basic principle
Open channel flow Basic principle INTRODUCTION Flow in rivers, irrigation canals, drainage ditches and aqueducts are some examples for open channel flow. These flows occur with a free surface and the pressure
4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.
CHAPTER 08 1. What is most likely to be the main driving force in pipe flow? A. Gravity B. A pressure gradient C. Vacuum 2.What is a general description of the flow rate in laminar flow? A. Small B. Large
Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.
Power Electronics Prof. K. Gopakumar Centre for Electronics Design and Technology Indian Institute of Science, Bangalore Lecture - 1 Electric Drive Today, we will start with the topic on industrial drive
HOT-WIRE AND HOT-FILM ANEMOMETRY
HOT-WIRE AND HOT-FILM ANEMOMETRY INTRODUCTION The hot-wire anemometer has been used extensively for many years as a research tool in fluid mechanics. In this paper hot-wire anemometry will refer to the
Table 9.1 Types of intrusions of a fluid into another and the corresponding terminology.
Chapter 9 Turbulent Jets SUMMARY: This chapter is concerned with turbulent jets, namely their overall shape and velocity structure. The first jets being considered are those penetrating in homogeneous
SPINDLE ERROR MOVEMENTS MEASUREMENT ALGORITHM AND A NEW METHOD OF RESULTS ANALYSIS 1. INTRODUCTION
Journal of Machine Engineering, Vol. 15, No.1, 2015 machine tool accuracy, metrology, spindle error motions Krzysztof JEMIELNIAK 1* Jaroslaw CHRZANOWSKI 1 SPINDLE ERROR MOVEMENTS MEASUREMENT ALGORITHM
ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS
ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS Many mechanical energy systems are devoted to transfer of energy between two points: the source or prime mover (input) and the load (output). For chemical
CO 2 41.2 MPa (abs) 20 C
comp_02 A CO 2 cartridge is used to propel a small rocket cart. Compressed CO 2, stored at a pressure of 41.2 MPa (abs) and a temperature of 20 C, is expanded through a smoothly contoured converging nozzle
Chapter 28 Fluid Dynamics
Chapter 28 Fluid Dynamics 28.1 Ideal Fluids... 1 28.2 Velocity Vector Field... 1 28.3 Mass Continuity Equation... 3 28.4 Bernoulli s Principle... 4 28.5 Worked Examples: Bernoulli s Equation... 7 Example
product application guide
Understanding Fan System Effects Fan Application FA/101-99 product application guide A technical bulletin for engineers, contractors and students in the air movement and control industry. The air moving
Force on Moving Charges in a Magnetic Field
[ Assignment View ] [ Eðlisfræði 2, vor 2007 27. Magnetic Field and Magnetic Forces Assignment is due at 2:00am on Wednesday, February 28, 2007 Credit for problems submitted late will decrease to 0% after
Swissmetro travels at high speeds through a tunnel at low pressure. It will therefore undergo friction that can be due to:
I. OBJECTIVE OF THE EXPERIMENT. Swissmetro travels at high speeds through a tunnel at low pressure. It will therefore undergo friction that can be due to: 1) Viscosity of gas (cf. "Viscosity of gas" experiment)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
The Secret of Hydraulic Schematics. BTPHydraulics www.iranfluidpower.com
The Secret of Hydraulic Schematics BTPHydraulics www.iranfluidpower.com www.iranfluidpower.com Table of Contents The Secret to Reading and Interpreting Hydraulic Schematics... 1 Hydraulic System Schematics...
APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS
APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS Section A.1. Flow Coefficients Definition The flow coefficient or pressure loss coefficient is used to relate the pressure loss