1 Michael Riedel Transformatorenbau GmbH PRODUCT OVERVIEW O v e r 2 5 y e a r s p r a c t i c e i n q u a l i t y p r o d u c t s

2 RSTN Sinle-Phase Transformers AC 380 / 400 / 420 // 230 V AC 380 / 400 / 420 // 24 V (up to 800 VA) AC 220 / 230 / 240 // 230 V AC 220 / 230 / 240 // 24 V (up to 800 VA) RSTN-transformers can be applied worldwide and meet national and international reulations. Particular advantaes of series RSTN Voltae adaptation via +-5% taps Compact construction at low weiht Hih reliability and lon service life Low total losses, thus hih efficiency Hiher than averae output at short-time duty (S3) EN / EN / EN Temperature reserves, even at ta 60 C/B full current load possible Hih stability of output voltae * Control transformers comp. to EN * Series RSTN UL-CSA Isolation transformers comp. to EN (output voltae AC 230V) Safety transformers comp. to EN (output voltae AC 24V) Identical construction type RSTN certified UL-CSA Identical construction type REIA in normal desin up to max. 600V resp. 20A, but without taps on the primary side. Secondary current up to 63A possible Type Weiht Dimensions in m m Attachment k a b c d e f RSTN 50 1, x45 M 4 RSTN 75 1, x46 M 4 RSTN 100 2, x53 M 4 RSTN 130 2, M 5 RSTN 200 2, M 5 RSTN 250 3, M 5 RSTN 320 4, M 5 RSTN 400 5, M 5 RSTN 500 6, M 5 RSTN 630 7, M 6 RSTN , ** M 6 RSTN , M 6 RSTN , M 6 RSTN , M 6 RSTN , M 6 RSTN , M 8 RSTN , M 8 RSTN , M 8 2 ** For 24V types measurement c + 10mm

3 RSSTN Sinle-Phase Transformers (EMC) Anti-interference transformers with special hih permeability shieldin AC 220 / 230 / 240 // 230 V EN / EN Particular advantaes of series RSSTN Excellent wide band interference voltae suppression of both symmetrical and asymmetrical factors (see chart) Voltae adaptation via +-5% taps Compact construction at low weiht Hih stability of output voltae Control transformers comp. to EN Isolation transformers comp. to EN (output voltae AC 230V) Type Weiht Dimensions in mm Attachment k a b c d e f RSSTN 50 1, x45 M 4 RSSTN 75 1, x46 M 4 RSSTN 100 2, x53 M 4 RSSTN 130 2, M 5 RSSTN 200 2, M 5 RSSTN 250 3, M 5 RSSTN 320 4, M 5 RSSTN 400 5, M 5 RSSTN 500 6, M 5 RSSTN 630 7, M 6 RSSTN , M 6 RSSTN , M 6 RSSTN , M 6 RSSTN , M 6 RSSTN , M 6 RSSTN , M 8 RSSTN , M 8 RSSTN , M 8 3

4 URST Universal Transformers f c d a e b AC // 115 / 230 V AC // 21 / 24 / 30 // 42 / 48 / 60 V (bis 800 VA) EN Universal control transformers series URST feature several taps primary and 2 to 6 taps secondary. Their use is recommended in cases of cramped storae space combined with the need for hih variety, makin the use of many diverse sinle-phase control transformers insensible. Particular advantaes of series URST Transformers for universal application Adaptation to input voltae via several primary windin taps 200 / 220 / 230 / 250 / 270 / 280 / 330 / 350 /370 / 380 / 390 / 400 / 420 / 430 / 440 / 450 / 470 / 490 / 500 / 550 V Hih stability of output voltae The provided 2 to 6 secondary windin taps increase application possibilities. On output-side, only the current allocated to each windin section may flow in each connection mode (parallel connection 2 x rated current, series connection 1x rated current) Hih reliability and lon service life Low total losses, thus hih efficiency Hiher than averae output at short-time duty (S3) Temperature reserves, even at ta 60 C/B full current load possible Control transformers AC V // 115/230V Control transformers AC V // 21/24/30V 42/48/60V Type Weiht Dimensions in mm Attachment k a b c d e f URST 100 2, x48 M 4 URST 160 3, x56 M 5 URST 250 4, x54 M 5 URST 320 5, x60 M 5 URST 400 6, x64 M 5 URST 500 7, x59 M 6 URST , x66 M 6 URST , x64 M 6 URST , x69 M 6 URST , x74 M 8 URST , x82 M 8 4

5 RDST Three-Phase Transformers Input and output voltae custom-desined The rectanular core stacks of our three-phase hih power core transformers are made of two-layered rain-oriented low-loss strips. The windins consist of hih rade insulated double-lacquered massive copper. Core and windins are vacuumimprenated toether and subsequently baked in the dryin oven for several hours. EN Particular advantaes of series RDST Dry-type core transformers comp. to EN / VDE 0532 Constructed for hih efficiency, temperature of the transformers remains well below the permissible heatin limit specified in VDE reulations Solid plannin uarantees an almost unlimited service life, even when overload of transformers occurs Connections up to 450A to series terminals, line bars or cable terminals (measurements not stated below) Maximum voltae (phase-phase) 2000V Isolation class F (averae temperature value 140 C) Individually desined, therefore variations of stated measurements and weiht possible Production up to protection class IP65 Three-phase isolatin transformers Three-phase autotransformer Type Power Weiht Dimensions in mm kva k a b c c1 ab 63А RDST 40 40, c+100 RDST 50 50, c+100 RDST 63 63, c+100 RDST 80 80, c+100 RDST , c+100 RDST , c+150 RDST , c+150 RDST , c+150 RDST , c+150 RDST , c+150 RDST , c+150 RDST , c+150 RDST , c+150 RDST , c+150 5

6 RNTU S / RNTG S Compact Sinle-Phase Power Supplies RNTU- AC 230V // DC 12V AC 230V // DC 24V AC 400V // DC 24V RNTG-Option: AC 230V // DC 24V EN Power Supplies of the series RNTU and RNTG are assembled with a safety transformer. Particular advantaes of series RNTU and RNTG Constructed in modern industrial desin, compact and space-savin Comprehensive contact protection throuh enclosed construction, protection class IP20 The modules can be snapped onto DIN mountin rails quickly and easily. From 5A upwards there is an additional provision for screw-fastenin Bridin of short-term power supply breakdowns 10ms RNTU, 15ms RNTG Residual ripple <3% RNTU, <2mV RNTG Interated fuses exclusively deliver short circuit protection Units are to be loaded only with rated current as indicated Identical units can be connected in parallel up to max. 90% load per unit * AC 230V // DC 24V, rated current RNTU from 1 to 10A and RNTG from 0.5 to 5A * Only for series RNTU UL / RNTG UL AC 230V // DC 12V, rated current RNTU from 1 to 10A AC 400V // DC 24V, rated current RNTU from 1 to 10A Custom-desined power supplies featurin other input voltaes (max. up to AC 400V) and other output voltaes: RNTU from DC 10 to 60V and rated current from 1 to 10A, RNTG from DC 5 to 30V and rated current from 0.5 to 5A Identical construction types RNTU and RNTG with UL-CSA approval (UL 508/CSA22.2-C) and input voltae AC 230/115V 60Hz Custom-desined power supplies with two output voltaes Type Weiht Dimensions in mm Attachment k Heiht Width Depth DIN-rail RNTU 24 S 0, TS 35x7,5 RNTU 48 S 1, TS 35x7,5 RNTU 72 S 2, TS 35x7,5 RNTU 120 S 3, TS 35x7,5 RNTU 180 S 5, TS 35x15 RNTU 240 S 6, TS 35x15 RNTG 12 S 0, TS 35x7,5 RNTG 24 S 0, TS 35x7,5 RNTG 48 S 1, TS 35x7,5 RNTG 72 S 2, TS 35x7,5 RNTG 120 S 4, TS 35x7,5 6

7 RDCUSV 3 50 S DC UPS Modules Option: DC 24V - USV RDCUSV-modules are parallely connected to the direct current output of the main supply and warrant a reliable supply to important enery consumers via a battery in case of fluctuations or total failure of the line voltae. Particular advantaes of series RDCUSV The patented technoloy of the UPS modules make switchin controllers unnecessary and avoid EMC interferences Construction accordin to the requirements of the operational voltae for electronic controls DIN EN (DC 20.4 to 28.8V) Uninterrupted switchin to battery operation Buffer time up to 30 sec. in case of full line failure Bridin durin peak loads, e.. startin current of motors or inrush current impulses of capacitive loads Automatic battery charin Potential free status output via screw clamps Modules installed in a plastic cabinet IP20, can be snapped quickly and easily onto DIN mountin rails Protection aainst short circuits, overtemperature and deep battery dischare Modules with activation threshold DC 22V, rated currents from 3 to 40A Modules with activation threshold DC 20.6V, rated currents from 3 to 50A Identical construction type RIPCUSV 5S for the supply of IPC (Industrial PC), includin serial interface Option Switch off of back-up time limit for loner UPS-times Type Weiht Dimensions in mm Attachment DIN k Heiht Width Depth mountin rails RDCUSV 3 S 0, TS 35x15 RDCUSV 10 S 3, TS 35x15 RDCUSV 16 S 3, TS 35x15 RDCUSV 20 S 4, TS 35x15 RDCUSV 30 S 4, TS 35x15 RDCUSV 40 S 6, TS 35x15 RDCUSV 50 S 6, TS 35x15 7

8 RPL 30W 960W Riedel Pri Line Primary Switched Power Supplies Sinle-phase AC V; AC V AC and AC V AC V AC V Three-phase 3AC V 3AC V Primary switched power supplies RPL do not require a power transformer, are compact and of low weiht. Particular advantaes of series RPL Wide input voltae rane (AC or DC) Adjustable output voltae via potentiometer Connection in parallel or series 25% power boost and 4s bonus time for occurrin peak loads Protection aainst overload, short circuit, overvoltae and overtemperature Easy fittin onto DIN mountin rail via snap-on Tricoloured status-led Interference output (potential free chaner) Usable as battery charer Input NTC-resistor 10kΩ for temperature controlled charin Input external switch on/off only RPL 125W, 250W, 960W 250WD EN / EN On stock 30W to 960W sinle-phase, 250W to 960W three-phase On stock with output voltaes DC 12V, 24V or 48V Other custom-desined input or output voltaes deliverable on short notice Includin active (RPL 250W and RPL 960W) or passive PFC (RPL 250WD - RPL 960WD, RPL 250PFC and RPL 480PFC). Other models without PFC Options Series diode on output for redundancy- and UPS-systems (decouplin diode) Analo input DC 0 to 10V to reulate output voltae from 0 to U nominal Electronic output fuse: savin disconnection of power supply at overload Type Weiht Dimensions in mm Attachment DIN k Heiht Width Depth mountin rails RPL 30 W 0, TS 35x7,5 RPL 60 W 0, TS 35x7,5 RPL 125 W 0, TS 35x7,5 RPL 250 W 1, TS 35x7,5 RPL 480 W 2, TS 35x7,5 RPL 960 W 3, TS 35x7,5 RPL 250 WD 1, TS 35x7,5 RPL 480 WD 2, TS 35x7,5 RPL 960 WD 3, TS 35x7,5 8

9 RDRKS 7,5 30 Three-Phase Compact Rectifier 3AC 380/400/420V // DC 24V Residual ripple: Without capacitor < 5% With capacitor < 2% Series RDRKS in modern industrial desin are assembled with a three-phase safety transformer and a three-phase bride rectifier. Particular advantaes of series RDRKS Voltae adaptation via +-5% taps Optimal layout reduces surface area Simple mountin via open-ended slot Compact construction at low weiht EN Hih reliability and lon service life Good value for reasonable price Low total losses Input AC V // Output DC 24V, rated currents from 7.5 to 30A, transformer, three-phase bride rectifier, varistor, resistor, LED, universal blade fuse Models with other input or output voltaes available on request RDRKS without smoothin capacitor, residual ripple < 5% RDRKS K includin electrolyte capacitor, residual ripple < 2% Type Weiht Dimensions in mm Attachment k a b c d e f RDRKS 7,5 (K) 3, M 5 RDRKS 10 (K) 4, M 5 RDRKS 15 (K) 6, M 5 RDRKS 20 (K) 9, M 6 RDRKS 25 (K) 10, M 6 RDRKS 30 (K) 11, M 6 9

10 RDRKN Three-Phase Compact Rectifier 3AC 380/400/420V // DC 24V Residual ripple: Without capacitor < 5% With capacitor < 2% Series RDRKN are assembled with a three-phase safety transformer and a three-phase bride rectifier. Particular advantaes of series RDRKN Voltae adaptation via +-5% taps Compact construction at low weiht Hih reliability and lon service life Low total losses, thus hih efficiency EN Over-averae hih performance at short time operation (S3) Temperature reserves, even at ta 60 C/B full load capacity possible Hih output voltae stability Input AC V // Output DC 24V, rated current from 10 to 60A Models with other input or output voltaes available on request. RDRKN without smoothin capacitor, residual ripple < 5% RDRKN K includin electrolyte capacitor, residual ripple < 2% Type Weiht Dimensions in mm Attachment k a b c d e RDRKN 10 (K) 4, M5 RDRKN 16 (K) 6, M5 RDRKN 20 (K) 9, M6 RDRKN 25 (K) 10, M6 RDRKN 30 (K) 11, M6 RDRKN 40 (K) 17, M6 RDRKN 60 (K) 22, M6 10

11 RSNT 5-15/ RSNT 10S-15S/ RSNT 20-60G Secondary Switched Power Supplies Sinle-phase AC 230V // DC 24V AC 400V // DC 24V Three-phase 3AC 400V // DC 24V Series RSNT are assembled with a sinle- or three-phase isolatin transformer and a subsequent switchin controller. Particular advantaes of series RSNT Riedel patents enable usae well bellow permissible interference level comp. to EN class B Adjustable output voltae from DC 0 to 30V via potentiometer Adjustable current limit from 0 to rated current via potentiometer Usable as battery charer Connection in parallel or series Protection aainst overload, short circuit, overvoltae and overtemperature Residual ripple < 30mV eff. EN Cabinets of protection class IP20 with G- and S-types Robust units of hih quality for heavy duty application Insensitive to interference voltaes Status display via 2 LEDs: reen for constant voltae operation and yellow for constant current operation On stock with output DC 24V, 5 to 15A sinle-phase and 20 to 60A three-phase Other custom-desins with input voltaes up to AC 690V RSNT or up to AC 400V RSNT G and RSNT S available on request Other custom-desins with output voltaes up to DC 60V available on request Options Analo input DC 0 to 10V or 4 to 20mA to reulate voltae and current at output Input remote switch on/off Potential free chane-over contact (overtemperature, undervoltae, overload) Type Weiht Dimensions in mm Attachment k a b c d e RSNT 5 5, M5 RSNT 10 6, M5 RSNT 15 7, M5 RSNT 10 S 5, M4 RSNT 15 S 9, /154 M4 RSNT 20 G 13, M6 RSNT 30 G 21, M6 RSNT 40 G 22, M6 RSNT 50 G 25, M6 RSNT 60 G 26, M6 11

12 PRODUCT OVERVIEW Sinle- and three-phase transformers up to 630kVA Chokes and filter choke systems Hih voltae supplies and coils Thyristor controller Manetic and subsequent controlled voltae stabiliser Sinle- and three-phase power supplies stabilized and unstabilized Battery charer DC-UPS-Modules and systems Primary and secondary switched power supplies Ratio rin transformers Inrush current limiters for transformers and power supplies Defrost- und solderin devices Customized developments Handed over by: Michael Riedel Transformatorenbau GmbH Max-Eyth-Straße 10 D Ilshofen-Eckartshausen Telefon ( ) Fax ( ) info@riedel-trafobau.de Produktion: rd/qf/07.07/2000 O v e r 2 5 y e a r s p r a c t i c e i n q u a l i t y p r o d u c t s

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Low and High Voltage Power Supplies

Low and High Voltage Power Supplies Low and High Voltage Power Supplies We work according to ISO 9001: 2008 Since 1994 Fug works according to the quality assurance system ISO 9001. All shipped units are checked and documented in our testing

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

SVR 12/24V and SVR Akku 12V Installation instructions

SVR 12/24V and SVR Akku 12V Installation instructions U aus Akku Na 12/24V SVR 12V/24V 700 800 500 SVR Akku 12V 700 800 550 230V~ L1 N SVR 12/24V and SVR Akku 12V Installation instructions Table of Contents General.... 3 Installation Putting into Operation...

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives 3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Content. TITAN VC2 Video Encoder/ Decoder from Page 5 Overview. SDSL Modems from Page 7 for Video transmission over 2 Mbit/s

Content. TITAN VC2 Video Encoder/ Decoder from Page 5 Overview. SDSL Modems from Page 7 for Video transmission over 2 Mbit/s Content TITAN VC2 Video Encoder/ Decoder from Pae 5 Overview SDSL Modems from Pae 7 for Video transmission over 2 Mbit/s TITAN VC2-2M from Pae 9 for Video transmission over 2-Mbit/s Leased Lines TITAN

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue

Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue 9 Power supplies Übersicht PROLINE Overview... 0 Power supplies Cabinets... 1 Wall mounted cases... 2 slimpower AC/DC switched-mode power supply 42 W, 3 HP Compact and low interference Accessories for

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

7 - Phaseo power supplies and transformers

7 - Phaseo power supplies and transformers /0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry. SITOP power supply Technical data SITOP Power Supply Answers for industry. Selection table SITOP power supplies Input voltage Output current modular smart LOGO!Power Special design, SIMATIC design Others

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

Catalog EN. Content Transformers for industrial applications

Catalog EN. Content Transformers for industrial applications Catalog Ed. 2013 Catalog Content Transformers for industrial applications Technical information 5 Quick product selection card Single and three-phase transformers 6 Quick product selection card Single-phase

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

Power Management & Supply. Design Note. Version 1.0, Nov. 2001 DN-EVALMF2ICE2A265-1. CoolSET 35W DVD Power Supply with ICE2A265.

Power Management & Supply. Design Note. Version 1.0, Nov. 2001 DN-EVALMF2ICE2A265-1. CoolSET 35W DVD Power Supply with ICE2A265. Version 1.0, Nov. 2001 Design Note DN-EVALMF2ICE2A265-1 CoolSET 35W DVD Power Supply with ICE2A265 Author: Harald Zöllinger Published by Infineon Technologies AG http://www.infineon.com Power Management

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

DC-DC Converter Module

DC-DC Converter Module 45 Features DC input range: 250-425V Input surge withstand: 500V for 100ms DC output: 24V Programmable output: 10 to 110% Regulation: ±0.2% no load to full load Efficiency: 88% Maximum operating temperature:

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

instabus KNX / EIB System System E F G H

instabus KNX / EIB System System E F G H Product name: Uninterruptible power supply (USV) 640 ma Design: REG (rail-mounted device) Article-no.: 1079 00 ETS search path: Gira Giersiepen / system components / power supply / power supply 640mA DRA

More information

SYSTEM DESCRIPTION Termination Boards

SYSTEM DESCRIPTION Termination Boards PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following

More information

Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Application Note TMA Series

Application Note TMA Series 1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x

More information

WE HAVE THE RIGHT POWER SUPPLY FOR YOUR APPLICATION

WE HAVE THE RIGHT POWER SUPPLY FOR YOUR APPLICATION WE HAVE THE RIGHT POWER SUPPLY FOR YOUR APPLICATION P L U S C O M P L E T E P E A C E O F M I N D W I T H H I G H E S T Q U A L I T Y & P R OVEN R E L I A B I L I T Y Switchmode Supplies Australia Core

More information

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA Highlights & Features Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed Designed for Class I Div. 2

More information

How To Build A Low Voltage Capacitor Lvcp

How To Build A Low Voltage Capacitor Lvcp Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

RIELLO ELETTRONICA. Master HP

RIELLO ELETTRONICA. Master HP RIELLO ELETTRONICA Master HP LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP) INDUSTRIAL PROCESSES INDUSTRIAL PLCS ELECTRO- MEDICAL DEVICES

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt TDB106015en/05.2013 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

More information

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA Highlights & Features Universal AC input voltage Power will not de-rate for the entire input voltage range Power Boost of 150% for 3 seconds Full corrosion resistant aluminium chassis SEMI F47 certified

More information

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation. PRELIMINARY TECHNICAL INFORMATION Three-phase Digital SCR Firing Board HIGHLIGHTS - Up to 480 V AC input supply voltage - Up to 700 V AC sync input - DSP controlled - Digital or analog input signaling

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

W 260: Standard photoelectric switch series for a broad range of applications

W 260: Standard photoelectric switch series for a broad range of applications W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

TEP 200WIR Series, 180 240 Watt

TEP 200WIR Series, 180 240 Watt TEP 200WIR Series, 180 240 Watt Features Chassis mount with screw terminal block Including EMI filter to meet EN 55022, class A Ultra wide 4:1 input voltage ranges 8.5 36, 16.5 75, 43 160 VDC EN 50155

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

MPR-Systems. Mini Power Racks 1200 W - 8100 W

MPR-Systems. Mini Power Racks 1200 W - 8100 W LUCAS-BENNING World Class Power Solutions With compliments Helmut Singer Elektronik www.helmut-singer.de info@helmut-singer.de fon +49 241 155 315 fax +49 241 152 066 Feldchen 16-24 D-52070 Aachen Germany

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Properties of electrical signals

Properties of electrical signals DC Voltage Component (Average voltage) Properties of electrical signals v(t) = V DC + v ac (t) V DC is the voltage value displayed on a DC voltmeter Triangular waveform DC component Half-wave rectifier

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts