72 x 72 analogue ammeters and voltmeter
|
|
|
- Marsha Gallagher
- 9 years ago
- Views:
Transcription
1 72 x 72 analogue ammeters and voltmeter PB _c Function The 72 x 72 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. AMP The ammeters measure in amps the current flowing through an electrical circuit. VLT The voltmeter measure in volts the potential difference (voltage) of an electrical circuit. PB _c PB _c AMP for standard feeder. AMP for motor feeder. VLT. Common technical data bbaccuracy: class 1.5. bbcompliance with standard IEC , IEC and IEC bbferromagnetic device. bbscale length: 62 mm over 90. bbmounting in enclosure or in cubicle. bbdegree of protection: IP52. bbmaximum operating position: 30 / vertical. bbtemperature: vvoperation: -25 C to +50 C vvreference: 23 C. bbinfluence of temperature on accuracy: ±0.003 % / C. bbutilisation frequency: 50/60 Hz. AMP specific technical data bbneeds a In/5 CT to be ordered separately. bbinterchangeable dials to be ordered separately. bbconsumption: 1.1 VA. bbpermanent overload: 1.2 In. bbmaximum overload for 5 s: 10 In. VLT specific technical data bbconsumption: 3 VA. bbpermanent overload: 1.2 Un. bbmaximum overload for 5 s: 2 Un. Catalogue numbers Type Scale Connection Cat. no. on CT AMP for standard feeder Basic device (delivered without dial) X/ In dial 0-50 A 50/ A 100/ A 200/ A 400/ A 600/ A 1000/ A 1250/ A 1500/ A 2000/ AMP for motor feeder Basic device (delivered without dial) X/ In dial A 30/ A 75/ A 200/ VLT V PLSED309005EN_book.indb 23 13/03/12 09:14
2 96 x 96 analogue ammeters and voltmeter PB _c Function The 96 x 96 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. AMP The ammeters measure in amps the current flowing through an electrical circuit. VLT The voltmeter measure in volts the potential difference (voltage) of an electrical circuit. PB _c PB _c AMP for standard feeder. AMP for motor feeder. VLT. Common technical data bbaccuracy: class 1.5. bbcompliance with standard IEC , IEC and IEC bbferromagnetic device. bbscale length: 80 mm over 90. bbmounting in enclosure or in cubicle. bbdegree of protection: IP52. bbmaximum operating position: 30 / vertical. bbtemperature: vvoperation: -25 C to +50 C vvreference: 23 C. bbinfluence of temperature on accuracy: ±0.003 % / C. bbutilisation frequency: 50/60 Hz. AMP specific technical data bbneeds a In/5 CT to be ordered separately. bbinterchangeable dials to be ordered separately. bbconsumption: 1.1 VA. bbpermanent overload: 1.2 In. bbmaximum overload for 5 s: 10 In. VLT specific technical data bbconsumption: 3 VA. bbpermanent overload: 1.2 Un. bbmaximum overload for 5 s: 2 Un. Catalogue numbers Type Scale Connection Cat. no. on CT AMP for standard feeder Basic device (delivered without dial) X/ In dial 0-50 A 50/ A 100/ A 200/ A 400/ A 600/ A 1000/ A 1250/ A 1500/ A 2000/ A 2500/ A 3000/ A 4000/ A 5000/ A 6000/ AMP for motor feeder Basic device (delivered without dial) X/ In dial A 30/ A 75/ A 200/ VLT V PLSED309005EN_book.indb 24 13/03/12 09:14
3 48 x 48 CMA and CMV selector switches _c CMA. Function The 48 x 48 selector switches are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. CMA The ammeter selector switch uses a single ammeter (by means of current transformers) for successive measurement of the currents of a three-phase circuit. CMV The voltmeter selector switch uses a single voltmeter for successive measurement of the voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit. Common technical data bbdurability: vvelectrical: operations vvmechanical: operations. bbagni contact. bboperating temperature: -25 C to +50 C. bbcompliance with standards IEC/EN bbdegree of protection: vvip65 on front face vvip20 at terminal level. Catalogue numbers Type Rating (A) Voltage (V) Number of positions Cat. no. CMA CMV Connection DB CMA. DB _c CMV. CMV. Reading 3 phase-to-earth voltages + 3 phase-to-phase voltages. Note: when connecting do not remove the pre-cabling. 25 PLSED309005EN_book.indb 25 13/03/12 09:14
4 DIN rail CMA and CMV selector switches _c _c CMA. CMV. Function CMA This 4-position ammeter selector switch uses a single ammeter (using current transformers) for successive measurement of the currents of a three-phase circuit. CMV This 7-position voltmeter selector switch uses a single voltmeter for successive measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit. Common technical data bbrotary handle. bbmaximum operating voltage: 440 V, 50/60 Hz. bbnominal thermal current: 10 A. bboperating temperature: -20 C to +55 C. bbstorage temperature: -25 C to +80 C. bbmechanical durability (AC21A-3 x 440 V): operations. bbdegree of protection: vvip66 on front face vvip20 at terminal level. bbelectrical durability: operations. bbconnection: jumper terminals with captive screws, for cables up to 1.5 mm 2. bbcomplies with standards: IEC/EN Catalogue numbers Type Rating (A) Voltage (V AC) Width in mod. of 9 mm Cat. no. CMA CMV Connection DB CMA. DB CMV. 26 PLSED309005EN_book.indb 26 13/03/12 09:14
5 CH hour counters DB Function Electromechanical counter that counts the operating hours of a machine or piece of electrical equipment. Giving a precise indication of operating time, the counter is used to decide when to carry out preventive maintenance. Common technical data bbelectromechanical display. bbmaximum display: hours. bbdisplay accuracy: 0.01 %. bbwithout reset. bbstorage temperature: -25 C to +85 C. bbconnection: tunnel terminals for 2.5 mm 2 cable. DB CH "DIN". CH "48 x 48". Specific technical data CH "DIN" bbconsumption: 0.15 VA. bboperating temperature: -10 C to +70 C. bbmounting on DIN rail. CH "48 x 48" bbconsumption: vv15607: 0.25 VA vv15608: 0.15 VA vv15609: 0.02 VA to 12 V and 0.3 VA to 36 V. bboperating temperature: -20 C to + 70 C. bbdegree of protection: IP65 on front face. bbmounting on front face of monitoring switchboards. Catalogue numbers Type Voltage (V) Width in mod. of 9 mm Cat. no. CH "DIN" 230 V AC ± 10 %/50 Hz CH "48 x 48" 24 V AC ± 10 %/50 Hz V AC ± 10 %/50 Hz to 36 V DC Connection DB DB load load CH "DIN". CH "48 x 48". 27 PLSED309005EN_book.indb 27 13/03/12 09:14
6 CI impulse counter DB Function Electromechanical counter designed to count impulses emitted by: kilowatt hour meters, temperature overrun detectors, people meters, speed meters, etc. Common technical data bbsupply and metering voltage: 230 V AC ± 10 %, 50/60 Hz. bbconsumption: 0.15 VA. bbmaximum display: impulses. bbwithout reset. bbmetering data: vvminimum impulse time: 50 ms vvminimum time between 2 impulses: 50 ms. bbstorage temperature: -25 C to +85 C. bboperating temperature: -10 C to +70 C. bbconnection: tunnel terminals for 2.5 mm 2 cable. Catalogue number Type Width in mod. Cat. no. of 9 mm CI Connection DB load load 28 PLSED309005EN_book.indb 28 13/03/12 09:14
7 Dimensions Capot de protection Ammeters, voltmeters, selector switches, impulse counter, hour counters Analogue ammeters and voltmeters DB Capot de protection Digital ammeters, voltmeter and frequency meter DB converti CMA and CMV selector switches DB converti 72 x 72 analogue ammeters and voltmeter DB Protection cover Terminal M4 96 x 96 analogue ammeters and voltmeter DB Protection cover Terminal M4 29 PLSED309005EN_book.indb 29 13/03/12 09:14
8 Dimensions (cont.) Ammeters, voltmeters, selector switches, impulse counter, hour counters 48 x 48 CMA and CMV selector switches DB (or 4.8) 24.1 (or 33) (with adapter) 22.3 (or 30.5) CI impulse counter and CH hour counter DB converti 48 x 48 CH hour counters DB converti 30 PLSED309005EN_book.indb 30 13/03/12 09:14
9 DM6000 series Functions and characteristics PE86261 PE86238 DM6000 series digital panel meter front display (above), and rear below) The PowerLogic DM6000 series digital panel meters offer the basic measurement capabilities required to monitor an electrical installation. Characterized by their rugged construction, compact size, and low installation costs, these state-of-the-art meters are ideal for control panels, motor control centres and genset panels. The PowerLogic DM6000 series digital meter is available in two different versions to better fit specific applications: DM6000, basic version; DM6200, basic version plus an RS485 port for Modbus communication. Applications Power monitoring operations. Equipment monitoring. Preventive maintenance. Main characteristics Easy to read display The bright, alphanumeric 15mm high LED display provides 3 lines for measurement values with 4 digits per line. This display auto-scales for Kilo, Mega and Giga values. Auto scrolling mode allows for easy reading. Analogue load bar The colour-coded analogue load bar indicates the percentage of load through 12 LED segments. Turbo Key access to information The Turbo Key gives access to the most commonly viewed parameters or enter set up mode with a single push of the button. Quick and easy installation Setup is done through the front panel keys. Quick entry to setup during power up by TURBO key. Direct connection for metering voltage inputs up to 480 V AC L-L. Colour-coded terminal board labeling The colour-coded label on the terminal board helps ensure accurate wiring. Secure settings Safeguard access to setup parameters with unique password protection. A keypad lock lets you display a user-selected page by default. Part numbers Description DM6000 digital meter with basic readings; no communications Same as DM6000 plus an RS485 communication port Schneider Electric METSEDM6000 METSEDM PLSED309005EN_book.indb 31 13/03/12 09:14
10 DM6000 series Functions and characteristics (cont.) PE86239 PowerLogic DM6000 series digital panel meter dimensions. Selection guide DM6000 DM6200 General Use on LV and HV systems b b Current and voltage accuracy 1.0 % 1.0 % Number of samples per cycle 20 at 50 Hz 20 at 50 Hz Instantaneous rms values Current Per phase & Neutral b b Voltage Average Phase to Neutral & Phase b b to Phase Frequency b b Power factor Average & per phase b b Unbalance Current, voltage b b Phase angle Between V & I, Ph1, Ph2, Ph3 b b RPM For generator only, speed calculated on generator voltage output and number of machine poles. b b Other measurements ON hours Operating time for meter in hours b b INTR Number of interruptions b b Display LED display b b Communication RS-485 port - 1 Modbus protocol - b 32 PLSED309005EN_book.indb 32 13/03/12 09:14
11 DM6000 series Functions and characteristics (cont.) Electrical characteristics Type of measurement True RMS up to the 9th harmonic 20 samples per cycle at 50 Hz 1.0 % of reading Measurement accuracy* Current and voltage Frequency 0.1 % of reading Power factor 1.0 % of reading * Additional error of 0.05% of full scale, for meter input current below 100mA Data update rate 1 second Input-voltage characteristics Inputs Measured voltage V1, V2, V3, Vn V AC L-L without PTs Up to 999 kv with external PTs Permissible overload 1.10 Un (480 V L-L) Burden 0.2 VA per phase max. Impedance VLL - 4 Mohms, VLN 2 Mohms Frequency range Hz Input-current CT ratings Primary 1 A ka characteristics Secondary 1 A - 5 A Measurement range 50 ma - 6 A (5 ma is the starting) Permissible overload 10 A continuous Burden 0.2 VA per phase max. Impedance < 0.1 ohm Power supply AC V AC at 50 Hz/60 Hz DC V DC Ride-through time 100 ms at 50 V Burden 3 VA max. Mechanical characteristics Weight kg (shipping), kg (unpacked) IP degree of protection Front: IP 51; Back: IP 40 Dimensions Bezel: 96 x 96 mm Depth: 80 mm behind bezel Panel cutout: 92 x 92 mm Environmental conditions Operating temperature -10 C to +60 C Storage temperature -25 C to +70 C Humidity rating 5 to 95 % RH non-condensing Altitude 2000 m Measurement CAT III Pollution degree 2 Protection class 2 Electromagnetic compatibility Electrostatic discharge IEC Immunity to electromagnetic RF fields IEC Immunity to electrical fast transients IEC Immunity to surge waves IEC Conducted disturbance immunity IEC Damped oscillatory waves immunity IEC Impulse voltage withstand 6 kv for 1.2/50 µs per IEC Conducted and radiated emissions CISPR11 Class A, FCC Part 15 Class A Safety and standards Safety construction Self extinguishable V0 plastic; UL 508 CE certification IEC61010 Yes Complies with Regulation (EC) n 1907/2006 of Dec named REACH (related to the Registration, Evaluation, Authorization and restrictions applicable to Chemical substances) Communication RS-485 port Display characteristics Integrated LED display Analogue load bar 2 terminals only; Baud rate up to 19,200 bps Protocols: Modbus RTU View 3 parameters together on 3 line, 4 digits per line display. Auto-scaling capability for Kilo, Mega, and Giga values. User-selectable default display page. Password protection for setup parameters. Colour-coded analogue indicator provides an option to select the full scale of the load bar based on the sanctioned power limit 33 PLSED309005EN_book.indb 33 13/03/12 09:14
12 DM6000 series Installation and connections DM6000 series meter dimensions PE86240 copie Front-panel mounting PE86241 copie 34 PLSED309005EN_book.indb 34 13/03/12 09:14
13 DM6000 series Installation and connections 3 phase 4-wire WYE connection with 3CTs and 3PTs Connection representation only. Other types of connection are possible. Refer to the DM6000 series Quick Start Guide for details. 2 phase 3-wire connection with 2 CTs PE86269 PE86268 Connection representation only. Other types of connection are possible. Refer to the DM6000 installation guide for details. 35 PLSED309005EN_book.indb 35 13/03/12 09:14
14 DM6000 series Installation and connections Single phase connection PE86270 Connection representation only. Other types of connection are possible. Refer to the DM6000 series Quick Start Guide for details. 36 PLSED309005EN_book.indb 36 13/03/12 09:14
15 Kilowatt-hour meters Kilowatt-hour meters PB103462_SE-35 PB103459_SE-35 PB103457_SE-35 PB iem2000t iem1zr/me1zr. ime3zr/me3zr. ime4zrt/me4zrt. Function Digital kilowatt-hour meters designed for sub-metering of active energy (rms) consumed by a single-phase or three-phase electric circuit with or without distributed neutral. iem2000t 40 A Single-phase kilowatt-hour meter with pulse output. ime1 / ME1 Single-phase kilowatt-hour meter. ime1z / ME1z Single-phase kilowatt-hour meter with partial meter. ime1zr / ME1zr Single-phase kilowatt-hour meter with partial meter and remote transfer of metering impulses (relay output). ime3 / ME3 Three-phase kilowatt-hour meter without neutral. ime3zr / ME3zr Three-phase kilowatt-hour meter without neutral, with partial meter and remote transfer of metering impulses (relay output). ime4 / ME4 Three-phase + neutral kilowatt-hour meter. ime4zr / ME4zr Three-phase + neutral kilowatt-hour meter with partial meter and remote transfer of metering impulses (relay output). ime4zrt/me4zrt Three-phase kilowatt-hour meter with or without neutral associated with external CTs (not supplied), with partial meter and remote transfer of metering impulses (relay output). Catalogue numbers Type Cat. no. Type Cat no. Rating (A) Voltage (V AC) Tolérance (V AC) Width in mod. of 9 mm Single-phase circuit (1L + N) iem2000t A9MEM2000T ±20 2 ime1 A9M17065 ME ±20 4 ime1z A9M17066 ME1z ±20 4 ime1zr A9M17067 ME1zr ±20 4 Three-phase circuit (3L) ime3 A9M17075 ME x x 230 ±20 8 ime3zr A9M17076 ME3zr x x 230 ±20 8 ime4zrt A9M17072 ME4zrt x x 230 ±20 8 Three-phase + neutral circuit (3L + N) ime4 A9M17070 ME x 230/400 ±20 8 ime4zr A9M17071 ME4zr x 230/400 ±20 8 ime4zrt A9M17072 ME4zrt x 230/400 ±20 8 Main technical data ME iem2000t Accuracy class 1 1 Frequency 48/62 Hz 48/62 Hz Consumption 2.5 VA < 10 VA Operating temperature -25 C to +55 C -25 C to +55 C -25 C to +65 C (32 A) Connection by tunnel terminals Top terminals: 6 mm 2 Top terminals: 4 mm 2 Compliance with standard IEC : - PMD/DD/K55/1 - PMD/SD/K55/1 (ME4zrt) Bottom terminals: 16 mm 2 Bottom terminals: 10 mm 2 IEC / IEC : - PMD/DD/K55/1 IEC (accuracy) IEC Sealable screw shield Except ME4zrt Yes 37 PLSED309005EN_book.indb 37 13/03/12 09:14
16 Kilowatt-hour meters Kilowatt-hour meters (cont.) DB Description iem2000t 1 Pulse output for remote transfer. 2 Green on/off indicator or to display a wiring error (status: Off). 3 Flashing yellow meter indicator (can be used to check accuracy of the equipment). 4 Terminal covers and lead sealing accessory. 5 Free holes for the comb busbar. DB iem2000t ime1/me1, ime1z/me1z, ime1zr/me1zr 1 Pulse output for remote transfer (ime1zr/me1zr). 2 Flashing meter indicator. 3 Total or partial meter display (ime1z/me1z, ime1zr/me1zr). 4 Wiring error indicator. 5 Push-button: total or partial meter display, reset partial meter (ME1z, ME1zr). 6 Sealing connection. DB imezr / MEzr. ime3/me3, ime3zr/me3zr, ime4/me4, ime4zr/me4zr, ime4zrt/me4zrt 1 Pulse output for remote transfer (ime3zr/me3zr, ime4zr/me4zr, ime4zrt/me4zrt). 2 Flashing meter indicator. 3 Total or partial meter display (ime3zr/me3zr, ime4zr/me4zr, ime4zrt/me4zrt) and CT rating display (ime4zrt/me4zrt). 4 Push-button: total or partial meter display (ime3zr/me3zr, ime4zr/me4zr, ime4zrt/ ME4zrt), reset partial meter, display or selection of CT rating (ime4zrt/me4zrt). ime4zrt / ME4zrt. Installation bbthe front panel of the product is IP40 and its housing is IP20. bbits installation must be appropriate to the operating conditions. bbthe protection must not be less than IP65 for outdoor use. DB Circuit-breaker Circuit-breaker Contactor Kilowatt-hour meter Kilowatt-hour meter Contactor Load Load Use with a contactor A measurement instrument is normally continually supplied. For a non-continuous supply (load switching), we recommend that you place the breaking device downstream from the measurement instrument to limit disturbances on the module inputs. These disturbances, particularly on inductive loads, may result in early ageing of the device. You must also place the measurement instrument at a distance from the breaking device to limit the risk of disturbance. Example: meter on a load switching 38 PLSED309005EN_book.indb 38 13/03/12 09:14
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Power management. PowerLogic System. Catalogue 2004
Power management PowerLogic System Catalogue 2004 PowerLogic System is PowerLogic System helps you control the cost, quality and reliability of electric power. With PowerLogic System, you can determine
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
M2M The measure of efficiency
M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet
PowerLogic power-monitoring units PM5350 power meter Technical data sheet Mid-range metering PM5350 Functions and characteristics PE86278 The PowerLogic PM5350 power meter offers all the measurement capailities
Power Meter Series 800
PowerLogic power-monitoring units Power Meter Series 800 Technical data sheet 2007 Functions and characteristics E90463 PB101813-51 PB101823-50 DB111799 Front view of Power Meter Series 800 meter with
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
FIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
Products and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Capacitor Protection Relay SPAJ 160 C. Product Guide
Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
7 - Phaseo power supplies and transformers
/0 Contents 0 - Phaseo power supplies and transformers Selection guide: Phaseo power supplies Modular, Optimum and universal ranges........................ page /2 Selection guide: Phaseo power supplies
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
Energy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
PowerLogic Sub Meter Display (SMD and SMDOPN)
Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting
more than a breaker it s a breakthrough Compact NSX
Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:
AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: advanced soft start and soft stop control protection functions that operate even when
Communicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Multifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001R02/13 2013 Class 2800 CONTENTS Description............................................ Page 2 Indoor Charging
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Current transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.