How To Write A Report On The Afghanistan Distribution System
|
|
|
- Claude Poole
- 5 years ago
- Views:
Transcription
1 AYBAK CITY (SAMANGAN PROVINCE) DISTRIBUTION SYSTEM CLOSE-OUT REPORT Prepared by: Raul Zuniga/Clayton Strampher/Jack Whippen/Tufail Memon Date of Report: May 3, 2006 Project/Action Area: Distribution Project Title: Rehabilitation of the Aybak City Distribution System Project Initiation Date: September 15, 2005 Original Completion Date: January 15, 2005 Final Completion Date: June 15, 2006 Under the: U.S. Agency for International Development - Afghanistan Energy Assistance Program Prepared by: Advanced Engineering Associates International, Inc L Street NW, Suite 725 Washington, DC 20036, USA Tel: / Fax: MARCH 2006 This publication was produced for review by the United States Agency for International Development. It was prepared by Advanced Engineering Associates International, Inc.
2 TABLE OF CONTENTS TOPIC PAGE 1.0 Project Strategic Impact Project Description and Objectives Project Description Overview of Project Objectives Progress To Date Issues to Consider in Distribution System Rehabilitation/Development- 9 ATTACHMENTS ATTACHMENT 1: Donor Distribution System Rehabilitation/Development List ATTACHMENT 2: Distribution System Specifications A: Material Specification B: Construction Specification ATTACHMENT 3: Handover Documentation of the Aybak Distribution System (Please reference Attachment 3 for a complete Table of Contents of the Handover Documentation. The complete documentation is included herein by reference and is attached to the electronic copy of this close out report in whole. A hard copy of the two (2) volumes of the Handover Documentation is available in the Afghanistan Energy Information Center (AEIC)) ATTACHMENT 4: Aybak City Electrical Map ATTACHMENT 5: List of Materials for the Additional 330 Connections in Aybak AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 2
3 1.0 Project Strategic Impact The Aybak (Samangan) Distribution Project is one component of the implementation of the strategy directing the development of the North East Power System) ( NEPS ). (Formerly called the North East Transmission System (NETS). The NEPS incorporates Donor actions encompassing activity of USAID, the World Bank ( WB ), the Asian Development Bank ( ADB ), Kreditanstalt fur Wiederaufban (KfW), the Government of India ( GoI ) and potentially other Donors. The direct purpose of the NEPS is to build the transmission capability of Afghanistan to take competitive advantage of lower cost imported power from the Central Asian Republics ( CAR s ) of Tajikistan, Uzbekistan and Turkmenistan, located on Afghanistan s northern border. Within the NEPS activity dual circuit 220 kv transmission lines will be built from each of the CAR countries indicated over the period from 2005 to The NEPS development has the potential to expand available electric capacity to Afghanistan from its current level of approximately 250 MW to a total available operating capacity of over 1000 MW within 4 years. NEPS represents a relatively quick solution to the electric generating capacity shortage which is inhibiting Afghanistan s economic development. The indirect and broader purpose of the NEPS is to also exhibit to the world community that a commercially self-sustaining transmission entity which integrates commercially viable generation and distribution components along a socio-politically stable energy corridor can be developed in Afghanistan. There are multiple actions, both on-going and dormant, but required, as well as outstanding issues that must still be resolved to make the NEPS a successful development. These actions and issues range from purely technical considerations, to commercial, financial, legal and sociopolitical concerns. The Ministry of Energy and Water ( MEW ), in cooperation with the Donors, continues to address, discuss and focus their actions in coordination meetings to resolve required actions and outstanding issues of concern. The purpose of noting these issues and the broader strategy directing the development of the NEPS is to put in context why the Aybak Distribution Project was initiated. The basic strategy driving the Aybak (also called Samangan City) Distribution Rehabilitation Project was three-fold: first, engender local support for the transmission line being built under NEPS by providing local benefit in those provinces through which the transmission line is being built; second, prepare the local systems to expand their distribution networks by upgrading the systems to a standardized 20 kv/400 volt system, and third, provide a starting self-sustaining seed system which would then be expanded by local resources over time. Concomitant with the third component was to develop the initial framework for a self-sustaining Rural Electric Association ( REA ) which would oversee further system development at the local level. The expectation, when Aybak was selected as the first USAID distribution rehabilitation project, was that the NEPS development would include provision of a substation off the 220 kv transmission line to service lower cost power to Samangan Province. This is one of the issues that remain outstanding at the time of this report. Without local support of the right of way (ROW) and building of the transmission line within NEPS the critical need for the development of a safe energy corridor may be lost. The fundamental strategic impact of the Aybak Project is directed to engender this local support. AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 3
4 2.0 Project Description and Objectives 2.1 Project Description The City of Aybak is the Provincial Capitol of Samangan Province. Samangan Province has a population of 378,000 people (Central Statistics Office) and encompasses an area of 11,262 square kilometers. As indicated on the map below, Samangan Province is located in the northeast central area of Afghanistan. The Project is best described by incorporation of the background information which directed and impacted its development. This includes the following: Aybak City is one of eighteen Provincial Cities/Towns designated by Donors as requiring rehabilitation of their distribution systems (Please reference Attachment 1: Donor Distribution System Rehabilitation/Development List). Aybak is one of eight cities which received a diesel generator from the World Bank. However the existing 6 kv distribution system was dilapidated and unreliable due to years of neglect and insufficient funds for repair as a result of conflict within Afghanistan. The value added by the generation provided could not be accessed fully. The existing generation unit is one caterpillar generator and a very aged Russian generator. The caterpillar generator has a capacity of 1100 KVA, 400V, 50 Hz. The Russian generator has a capacity of 120KVA, 400V, 50 Hz. The USAID Aybak Project was directed to rehabilitate and upgrade the 6 kv system to a nationally informally adopted standard of medium voltage service at 20 kv and low voltage at 400/230 volts. (Please reference Attachment 2: Distribution System Specifications) AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 4
5 The Distribution System Specifications are taken from DECON specifications as applied to Kabul. The lack of an official national standard led to the adoption of the DECON specification as an informal standard. The scope of the work was the installation of a 20 kv overhead distribution system within an area of 2 kilometers by 3 kilometers inside the city of Aybak The Aybak Distribution rehabilitation project was tendered on behalf of AEAI by Fluor, AEAI s approved sub-contractor. ZMD from Turkey was selected as the construction entity under Fluor management reporting to AEAI. AEAI was responsible for system design and for materials acceptance. Fluor was responsible for construction management and Quality Control/Quality Assurance. The system rehabilitation was to replace 3000 customer connections within Aybak. This rate of replacement was based upon indications from DABM Aybak that there were 2400 customer connections. The Project as initiated was to rehabilitate the electric services of all customers and add an additional 600 connections to the system. The 3000 connections as a target number was based upon available data indicating each customer connection required a maximum of 300 watts. All system components were to be replaced and upgraded. This included new transformers, switchgear and Medium and Low voltage circuits. Replacement would include new fuse box services into the individual customer locations. (NOTE: DABM does not provide the service laterals beyond the meter box into customer premises and considers such provision, including the meter, to be the responsibility of the customer.) Aybak s exiting power distribution system is operated by DABM under the direction of DABM s Aybak manager, Mr. Shakoor. Almost 2400 consumers were connected to the two generators via the aged and dilapidated 6 kv system. The existing distribution line that served customers is not commercially viable. The system could not produce revenue requirements to properly tool DABM to (1) maintain the system nor (2) could the system be expanded. The proposed new seed distribution system with 3000 consumer connections consists of 4MV primary circuit distribution lines, open secondary and direct burial secondary lines. Four consumers will share a meter box that will consist of four digital meters which will be connected to each customer service fuse box. A new 5MVA, 400V/20KV transformer and 4MV circuit s switchgear will be installed at the heart of Aybak city. The existing 6KV distribution voltage will be retired and new 20KV is the replacement. There are 14 new distribution transformers (50KVA & 100KVA) to be installed with a rating of 20KV/0.4KV. The overhead distribution lines will consist of concrete poles, steel cross arms and ACSR wire. Open secondary wire shall be bundled insulated conductors. The underground cable was specified to be suitable for direct burial. 2.2 Project Objectives The strategic objectives of undertaking the Aybak Distribution Project are as noted above. In implementing the project the specific project objectives were as follows: Replace the dilapidated 6 kv system and prepare Aybak to the extent feasible for utilizing the additional capacity which would come available with NEPS. AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 5
6 The present 6kV distribution system is very old and the wires are undersized causing excessive voltage drop. Many of the power poles are rotted and in places DABM had jury-rigged the use of short wood poles and spliced them to another wood pole just to raise the lines above ground with insufficient clearances. Undersized and untreated wood pole are commonly used. The existing system losses were high and the system could not self-sustain to the extent of allowing capital accumulation to upgrade and expand. The objective was to replace the system and provide the requirements to allow the system to self-sustain and grow. Inclusive in this was the objective of providing training in basic technical and commercial management of the system under a Rural Electric Association Progress to Date: The Aybak distribution project was released following USAID approval and Consent to proceed on September 1, The scheduled date of completion was December 14, Following release the following actions were accomplished. ZMD mobilized to Aybak relatively slowly. Complete mobilization did not occur until late October, Upon mobilization ZMD: Prepared town mapping and determined consumer loads. Designed 20KV primary distribution lines, location of distribution transformer 20KV/240V, overhead secondary lines and underground cables installations. Designed the 5MVA substation outdoor type installation and 20KV Switchgear complete with one main breaker and four branches of circuit breakers. Designed sizes of primary and secondary wires. Designed sizes of substation and distribution transformer and protection devices. Performed a voltage drop calculation and sectionalizing study of the whole system. All designs were reviewed and approved by AEAI personnel assigned to Aybak. Following design and materials approval per the specifications ZMD initiated construction. During the period from mid-october onward material delivery delays and fundamentally poor planning and delay in design by ZMD led to project scheduled completion delays. Initially the announced delay was until January 2006 which continued to slip until final completion of the original contract on April 21, (Please reference Attachment 3: Handover Documentation of the Aybak Distribution System). ZMD accomplished the following over the extended period: Prepared staking sheets to record height of poles, type of pole assembly, primary and secondary assemblies, wire sizes to be installed, distance from pole to pole, guy wire and anchor assemblies and proposed transformer pole location. Prepared pole hole digging, pole erection, installation of primary & secondary assemblies, guy wire & anchor log assemblies installations, stringing of wires, application of armor rod and tie wire. There were a total of fourteen (14) pole platform mounted distribution transformers rated at 50 KVA and 100 KVA. Each distribution transformer included a distribution panel with a power meter to record total power output at the low voltage side of the transformer. Prepare trench excavation & backfilling, lay of cables, meter and fuse box installation. Each meter box contained as many as four (4) meters with service then fed to molded case circuit breaker boxes ( fuse boxes ) located in each customers premise. Testing and commissioning acceptance of the 20 kv distribution system rehabilitation carried out by ZMD/Fluor. The turn over of an agreed list of system spare parts from ZMD/Fluor to AEAI to DABM. AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 6
7 ZMD provided a week long hands-on basic operations and maintenance training program for linemen and for the operation of switchgear. DABM Aybak was provided a basic set of system maintenance tools by ZMD. AEAI has provided additional tools to complete requirements for system maintenance including a bucket truck. A copy of the Aybak City Electrical Map is provided below (please reference Attachment 4: Aybak City Electrical Map for more clarity) The city of Aybak is cut in two by the Aybak River indicated in green. The new 20 KV system is placed in the western side (bottom half of the map) of the city. The eastern side of the city (upper half of the map) will remain with the 6 kv system to be upgraded and expanded by DABM using portions of the 6 kv system removed from the western side of the city when the 20 kv system is again energized for operations. AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 7
8 During system installation it was found that shop areas on the western side of the city were master metered. For example, one building with a nominal thirty-five shops had only one meter. The decision was taken to meter all shops individually both to promote knowledge of and more efficient use of electric energy and to insure better revenue collection. The contract of ZMD called for 3000 connections. As individual meters were installed it was determined that and additional 330 connections would be required. The price proposal provided by ZMD/Fluor was determined to be too costly based on available alternatives determined from bids for system development in Qalat and Tirin Kot. Part of the lump-sum fixed price contract of Fluor/ZMD was the removal of the 6 kv system being rehabilitated. During the construction process ZMD wished to remove the 6 kv system. This would have resulted in cutting service to much of Aybak which was politically and socially unacceptable. ZMD/Fluor was directed to work around the 6kV system and leave it operational. The requirement to add 330 connections and continue to maintain service to the remaining 6 kv system necessitated the following: Development of the engineering and design to incorporate the additional 330 connections. In this process an additional 220 connections were identified which DABM will undertake to incorporate into the system Contracting with Afghan Electric Power Corporation (AEPC) following Consent from USAID to provide the additional 330 connections. (These connections included government facilities and Mosques by-passed by ZMD on the basis that the service required exceeded the specifications.) Contracting, following USAID Consent to proceed, for the procurement of two (2) 500 KVA generators to supply the eastern part of the city s 6 kv system which will remain operational following completion of the 20 kv system. (NOTE: An additional 300 kwh in available electric energy enables USD $ 1000 in Gross Domestic Product addition) Procurement of two (2) 40,000 liter fuel tanks for the generators and required transformers for the interconnection of the generators to the system. DABM provided the circuit breakers required to complete the interconnection and one (1) fuel tank at the DABM switchgear station yard. Contracting with AEPC to remove the 6 kv system in that portion of Aybak where the 20 kv system will serve once the extension of the system is completed and energized and the remaining portion of the 6 kv system is prepared for energization. The materials required for the additional customer expansion were by agreement with USAID taken from materials ordered for Qalat and Tirin Kot. (Please reference Attachment 4: List of Materials for the Additional 330 Connections,) The target date of system completion and turnover to DABM is June 15, The commercial and managerial development directed to achieving self-sustainability of the Aybak system has and is occurring at the same time as the technical development. The actions taken include: The development of a Rural Electric Association (REA) was initiated. An interim Board of Commissioners was appointed following discussions with civic leaders and the Governor of the province. (The Board will be elected by electric consumers in the future). A one week training session on REA concepts and management was provided to the Board in Kabul. (Please reference the REA Close out Report available at the Afghanistan Energy Information Center for details) AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 8
9 A one week training session on basic accounting and management was provided to REA and DABM Aybak management in Kabul. An AEAI computer trainer from Mazar-e-Sharif was moved to Aybak with all equipment to provide a month long training session on basic computer use including MS Office tools to DABM Aybak administrative staff. An AEAI Billing and Collections expert will provide a simple computer based accounting and billing and collections system and training in its use to DABM Aybak administrative staff, DABM Aybak was provided additional low cost office space needed for its administrative staff. 3.0 Issues to Consider in Distribution System Rehabilitation/Development Various events lead to public relations problems that required rapid adjustment of activity in Aybak. These events provide some guidance on what needs to be actioned and avoided in distribution system development projects. Expectations need to be managed from the very start of a project. This cannot be done through the local Governor alone. The formation of the local Board of Commissioners at the start of the project and detailed briefings to them proved beneficial in controlling perceptions and rapidly hearing of and quelling local concerns. Construction contractors and their field staff need to be well versed (1) in local custom and (2) the place a particular project has in overall development of the electric system in order to better inform the public as they are working. A day spent on local and project orientation should be built into all mobilization actions. For contractual reasons the system materials supply and construction was separated from system design and materials approval which was again separated from construction contract management and QA/QC. This proved extremely cumbersome in management and added cost and should be avoided. ZMD had the experience to construct the system but the experience was not in Afghanistan. They underestimated materials delivery and logistical issues which ultimately caused delay. They did not provide the appropriate tooling due to the belief that the tooling could be found in Afghanistan, which it cannot. For example, line swivels and Kellum grips for properly pulling, laying and sagging lines. ZMD was not aware of local customs and cultural requirements. This lead to incidents of protest to local authorities that had to be managed but which could have been avoided. As initially conceived and directed by USAID the intent of the Distribution System Development Project was to provide seed systems by new system development or old system rehabilitation and provide institutional development assistance in the form of REA s that would then be capable of growing the seed. The Aybak seed was based on 300 watts per customer with an indication form DABM that there were 2600 customers. Ultimately it was found that there are closer to 3500 customers with an expected load of approximately 1000 watts per customer. This required adjustment in new connections and additional generation. A more detailed customer survey should be taken prior to system design. DABM does not know its full customer base and customer end usage. In order for REA development to be successful a minimum of one year of assistance in development needs to be provided. Afghanistan is, as is known, a community based culture. It is an error to provide only part of a city or town with a rehabilitated distribution system. AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 9
10 This action divides the community and leads to issues of social inequity. In addressing other cities and towns it is recommended that USAID should either build/rehabilitate the entire city/town area or avoid going into the area. AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 10
11 ATTACHMENT 1 DONOR DISTRIBUTION SYSTEM REHABILITATION DEVELOPMENT LIST AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 11
12 ATTACHMENT 2 DISTRIBUTION SYSTEM SPECIFICATIONS AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 12
13 ATTACHMENT 3 HANDOVER DOCUMENTATION OF THE AYBAK DISTRIBUTION SYSTEM (TABLE OF CONTENTS OF THE HANDOVER DOCUMENTATION. THE COMPLETE DOCUMENTATION IS INCLUDED HEREIN BY REFERENCE AND IS ATTACHED TO THE ELECTRONIC COPY OF THIS CLOSE OUT REPORT IN WHOLE. A HARD COPY OF THE TWO (2) VOLUMES OF THE HANDOVER DOCUMENTATION IS AVAILABLE IN THE AFGHANISTAN ENERGY INFORMATION CENTER (AEIC)) AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 13
14 ATTACHMENT 4 AYBAK CITY ELECTRICAL MAP AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 14
15 ATTACHMENT 5 LIST OF MATERIALS FOR THE ADDITIONAL 330 CONNECTIONS IN AYBAK AEAI CLOSE-OUT REPORTS: AYBAK DISTRIBUTION SYSTEM 15
INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION
INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions
Hyperlinks are Inactive
Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)
FIXED CHARGE: This is a cost that goes towards making the service available, including
ELECTRICITY BILL COMPONENTS FIXED CHARGE: This is a cost that goes towards making the service available, including installation and maintenance of poles, power lines and equipment, and 24-hour customer
Energy Sector Afghanistan
دافغانستان اسلامی جمهوريت جمهوری اسلامی افغانستان Islamic Republic of Afghanistan Office of Senior Adviser for Mining & Energy Energy Sector Afghanistan Importance of Renewable Energy for Afghanistan Renewable
BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE
BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877
SHE Transmission. 2015_10_30 Transmission Losses Strategy Rev 2.0 October 2015
SHE Transmission 2015_10_30 Transmission Losses Strategy Rev 2.0 October 2015 Summary This paper presents SHE Transmission s views and approach on the impact of transmission losses on the transmission
BC Hydro. Electric Distribution System Cost of Service Study
BC Hydro Electric Distribution System Reimer Consulting Group Inc. Arnie Reimer May 7, 2010 Table of Contents 1. Executive Summary... 3 2. BC Hydro Electric Distribution System... 4 2.1. General Description...
BASIC NEC CODE RULES AND DESIGN PRACTICE
BASIC NEC CODE RULES AND DESIGN PRACTICE Wire Ampacity and Size Circuit Breaker Size 1. Maximum loading for any branch circuit is 80% of rating of circuit for ampacity of wire for any load. NEC 220-2,
Step 1: Application Instructions
Step 1: Application Instructions CONTENTS Introduction Customer and Electrician Instructions Completing Section 1 or Section 2 Definitions INTRODUCTION Every effort has been made to provide clear instruction
Presented by: Rhonda Irby Business Development Ghazanfar Group. Ghazanfar Group. Afghanistan s Leading Energy Company
Presented by: Rhonda Irby Business Development Ghazanfar Group Ghazanfar Group Afghanistan s Leading Energy Company Overview of the Ghazanfar Group Presented by Rhonda Irby Business Development Manager
SECTOR ASSESSMENT (SUMMARY): ENERGY 1. 1. Sector Performance, Problems, and Opportunities
Country Partnership Strategy: Bangladesh, 2011 SECTOR ASSESSMENT (SUMMARY): ENERGY 1 Sector Road Map 1. Sector Performance, Problems, and Opportunities 1. Power generation gap. Bangladesh endures long
Underground Commercial Electric Service
Underground Commercial Electric Service SCANA Corporation 2013 Revised: June 2013 Table of Contents SECTION PAGE I. Specification and Requirements 2 A. General B. Definition of Terms C. Company and Developer
How To Get A Power Line Extension
GUIDELINES FOR COMMERCIAL ELECTRIC SERVICE HOOKUP 1 Steps to Commercial Service Pay the Design Deposit Commercial Buildings: Up to 1, sq ft = $1,. 1, 5, sq ft = $2,. Over 5, sq ft = $3,. Commercial jobs
Electric Service Guide for Commercial Construction
Electric Service Guide for Commercial Construction Contents Contacting KCP&L... 2 Voltages... 2 Temporary Service... 2 Customer-Provided Temporary Service... 2 KCP&L-Provided Temporary Service.... 2 Current
IRRIGATION PUMPING Table of Contents - Section 900
IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS
4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS
4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS for DATA CENTERS Michael Mosman, PE Chief Technical Officer CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED MEDIUM VOLTAGE
GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables
Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,
261000 Medium Voltage Electrical Distribution
Sections Included In This Standard: 1.1 General 1.2 Underground Cable 1.3 Medium Voltage Switches 1.4 Transformers 1.5 Electrical Manholes 1.6 Switch Vaults 1.7 Distribution Switchgear/Switchboards This
SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD
SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD HOLLAND CLIFF HEWITT ROAD 230 KV TRANSMISSION LINE PROJECT ELECTRIC ALTERNATIVE EVALUATION STUDY BLACK & VEATCH CORPORATION B&V Project 146026(G)
Exhibit (DRD-1) Page 1 of 2 Qualifications of Panel. Henry Host-Steen
Exhibit (DRD-1) Page 1 of 2 Qualifications of Panel Henry Host-Steen I have been retained as a Contractor by New York State Electric & Gas Corporation ( NYSEG ). I am currently employed by Manpower Professional,
Q: PLEASE STATE YOUR NAME AND BUSINESS ADDRESS. A: Gerry Sheerin. Sheerin Technical, 25 Eastville Avenue, Toronto, Ontario Canada
DIRECT TESTIMONY OF GERRY SHEERIN, P. ENG ON BEHALF OF PIEDMONT ENVIRONMENTAL COUNCIL BEFORE THE STATE CORPORATION COMMISSION OF VIRGINIA CASE NOS. PUE-00-0001 AND PUE-00-000 1 1 1 1 1 1 1 1 1 Q: PLEASE
MEDIUM VOLTAGE. Michael Mosman, PE. CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED
MEDIUM VOLTAGE ELECTRICAL SYSTEMS for DATA CENTERS Michael Mosman, PE Chief Technical Officer CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED CCG Facilities Integration Incorporated
POWER CORPORATION Requirements for Distribution Wires Access
POWER CORPORATION Requirements for Distribution Wires Access Contact Information: ENMAX Power Corporation 8820 52 St SE Phone: 514-3700 Calgary, Alberta Fax: 514-3719 T2C 4E7 Version 3.0 January 2005 i
Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada
Whitepaper Modular Substation Cable Termination Design Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract The methods for cable penetrations into modular industrial substations are
High Voltage. Hazards
High Voltage Hazards HV Hazards Substations, Overhead Lines, Cables Safety Incidents Requirements for Designers, Constructors Construction Regs 2013 and other Legislation Codes of Practice Other Guidance
PEND OREILLE COUNTY PUD. Quality Service at Low Cost RATES FOR ELECTRIC SERVICE
PEND OREILLE COUNTY PUD Quality Service at Low Cost RATES FOR ELECTRIC SERVICE Effective July 1, 2015 Contents What Is a Public Utility District... 2 Services Offered By The District... 3 Residential Service...
Information Paper. Power System Transmission and Distribution Equipment and Material Suppliers in Central Asia
Information Paper Power System Transmission and Distribution Equipment and Material Suppliers in Central Asia Disclaimer: Companies identified in this Information Paper are examples of potential suppliers
Electric Service Guide for Residential Construction
Electric Service Guide for Residential Construction Table of Contents Contacting KCP&L... 2 Existing Home Remodeling or Additions... 2 Changing your electric service... 2 What you need to know before you
UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design
Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,
REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING
REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING Revised October, 2013 TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 REQUIRED DRAWINGS... 3 2.1 Site Plan... 3
Grid Solutions. PROJECT MANAGEMENT SOLUTIONS for infrastructure projects from Border States. Border States
Border States Grid Solutions PROJECT MANAGEMENT SOLUTIONS for infrastructure projects from Border States Aging infrastructure, increased energy demands and emerging markets have fueled the growth of transmission,
Distribution Substation Manual (DSM) Section I - Introduction
(DSM) Section I - Introduction March 2007 Document release information Client Project name Western Power Distribution Substation Manual Document number 3463019 Document title Revision status Introduction
Networks. ESB Networks Ltd Basis of Charges for Connection to the Distribution System. Commercial and Customer Asset Management ESB Networks Ltd.
Networks ESB Networks Ltd Basis of Charges for Connection to the Distribution System Revision Date: 14/01/20010 Revision No.: 1 Document No: DOC-10129-AXQ Issued by: ESB Networks Ltd Approved by : CER
Litigation Services & Information
Litigation Services & Information Laurence "Lo" Lehman, P.E. Lehman Engineering Company Lehman Engineering has been providing engineering, design, and consulting services for electrical power systems to
Customer Substation Manual 08/05/02
Customer Substation Manual Table of Contents Section Page 2 of 85 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation
Requirements for the Attachment of Communication Cable Facilities on PPL Poles
Page 99 of 137 Requirements for the Attachment of Communication Cable Facilities on Replaces: URS-3002 URS-3004 URS-101C-304 A-157649 Page 100 of 137 Reference Notes for Drawings: General 1. The term communication
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
AMSC s Superconductor Cable Technologies for Electric Utilities
International Workshop 2014 AMSC s Superconductor Cable Technologies for Electric Utilities Michael Ross, P.E. Managing Director of Superconductor Power Systems AMSC Corporate Facts Headquartered in MA,
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
environment briefing02
PRODUCED BY THE SAFETY, HEALTH & ENVIRONMENT GROUP OF THE ENERGY NETWORKS ASSOCIATION - JULY 2006 environment briefing02 transporting electricity Overhead Lines or Underground Cables? Introduction The
DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2. Detroit...2-1-5 Ann Arbor...2-1-6 Mt. Clemens...2-1-7 Port Huron...2-1-8
DISTRIBUTION SYSTEMS INDEX NOV 06 SECTION 2 Kinds and Uses of Service... 2-1-1 and 2-1-2 Wye Network Area Maps Detroit...2-1-5 Ann Arbor...2-1-6 Mt. Clemens...2-1-7 Port Huron...2-1-8 Transformer Connections
Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering
Title 20 PUBLIC SERVICE COMMISSION Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES Chapter 02 Engineering Authority: Public Utility Companies Article, 2-121, 5-101 and 5-303, Annotated Code of Maryland.
Please check with your local inspection authority for any additional requirements before installation.
Specifications for Residential Overhead Electric Service Installation This brochure addresses most typical residential overhead service installations. Variances for the following specifications must be
BOARD NOTICE COUNCIL FOR THE BUILT ENVIRONMENT. Notice No... 2011
BOARD NOTICE COUNCIL FOR THE BUILT ENVIRONMENT Notice No.... 2011 NOTICE IN TERMS OF THE COUNCIL FOR THE BUILT ENVIRONMENT ACT, 2000 (ACT NO. 43 OF 2000) The Council for the Built Environment has under
ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
Electricity from the Power Plant To the Consumer
Electric Transmission Lines Electricity from the Power Plant To the Consumer The Nature of Electricity Electricity must be used as it is generated. Unlike other commodities, there is very little ability
RCP2 Portfolio Overview Document
RCP2 Portfolio Overview Document Portfolio: Expenditure Class: Base Capex Expenditure Category: Grid Replacement & Refurbishment As at date: 15 November 2013 Expenditure Forecast Real 2012/13 NZ$ (m) 2015-2016
When power interruptions happen.
When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage
3. TYPES OF SERVICE AVAILABLE. 3.1 Scope
3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service
Emera Maine Proposed Potential Transmission Projects. Line Identification Line 75 - KR Sub. Estimated Cost $201,464 $0 $3,200,000
L75 & BW3 Rebuild ROW Phase I Keene Rd. Expansion for Oakfield Wind KR Transformer Addition Line Identification Line 75 - KR Sub Location Bangor Chester Chester Estimated Cost $201,464 $0 $3,200,000 Voltage
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC 28262. DRAFT V0.
Innovation Park Charlotte. NC 28262 DRAFT V0.1 Page 2 CyberFortress Data Center at Innovation Park BECO South purchased Innovation Park in March 2010 and immediately launched a dramatic top-to-bottom $30M
XLPE PRODUCTION PLANT FOR THIRUVALLA UNIT OF TRACO CABLE LTD
PROJECT PROFILE ON XLPE PRODUCTION PLANT FOR THIRUVALLA UNIT OF TRACO CABLE LTD Prepared by: TRACO CABLE COMPANY LIMITED IV TH FLOOR, KSHB OFFICE COMPLEX PANAMPILLY NAGAR KOCHI-682036 September 2012 PROJECT
Governor s Two-Storm Panel: Distribution Infrastructure Hardening Options and Recommendations
Governor s Two-Storm Panel: Distribution Infrastructure Hardening Options and Recommendations Dana Louth, CL&P VP - Infrastructure Hardening December 14, 2011 0 Topics for today s presentation Review of
PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.
INTRODUCTION These rules are issued for use by Customers, builders, electrical contractors, architects, engineers, etc. The rules require the installation of safe and adequate wiring and electrical equipment,
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
Treasure Valley Electric Plan - Community Advisory Committee
Treasure Valley Electric Plan - Community Advisory Committee What is a transmission line and why are they necessary? A transmission line is used to conduct electricity between two points. Without high
BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION'^^ j E DIRECT TESTIMONY RAJESH GUPTA PROJECT MANAGER, ENTERGY SERVICES, INC.
BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION'^^ j E s : D IN THE MATTER OF THE APPLICATION OF ENTERGY ARKANSAS, INC. FOR A CERTIFICATE OF ENVIRONMENTAL COMPATIBILITY AND PUBLIC NEED TO CONSTRUCT AND OPERATE
TRANSPORT SECTOR ROADMAP AND THE INVESTMENT PROGRAM I. Roadmap
TRANSPORT SECTOR ROADMAP AND THE INVESTMENT PROGRAM I. Roadmap 1. Launched in 2008, the government s Afghanistan National Strategy (ANDS) is a Millennium Goals (MDGs) based action plan and road map for
Power Plant Electrical Distribution Systems
PDH Course E184 Power Plant Electrical Distribution Systems Gary W Castleberry, PE 2008 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
Electric Service Guide for Residential Construction
Electric Service Guide for Residential Construction TABLE OF CONTENTS Contacting KCP&L... 2 Existing Home Remodeling or Additions... 2 Building a New Home... 3 KCP&L Services at a Glance... 4 Current Transformers...
ESB Networks Ltd Statement of Charges
ESB Networks Ltd Statement of Charges Revision Date: 9/2014 Revision No.: 11 Document No: DOC-101209-AXR Issued by: ESB NETWORKS LTD Approved by : CER Effective Date: 01/10/2014 Commercial and Renewable
Wellesley Municipal Light Plant. Standard Requirements for Electric Service
Wellesley Municipal Light Plant Standard Requirements for Electric Service Index Section 1... General Information Section 2..General Requirements for Service Section 3. Types of Available Service Section
Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.
Arc Flash Mitigation Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear. Distance is Safety We will discuss through examples of actual occurrences and possible
Project Implementation and Administration Seminar Case Studies
BP01 PHILIPPINES EDUCATION PROJECT The project will construct and equip a new Institute of Technology in the Philippines. Table 1 provides project cost estimates. The work includes Construction of an academic
CITY OF GLENDALE CALIFORNIA REPORT TO CITY COUNCIL
FORM CM-36 CITY OF GLENDALE CALIFORNIA REPORT TO CITY COUNCIL February 7,2012 AGENDA ITEM Request for Approval to Issue a Request for Qualification (RFQ) of Firms, and Request for Proposal (RFP) to Engineer,
ESB Networks Response. ERGEG Consultation. Voltage Quality Regulation in Europe
NETWORKS ESB Networks Response to ERGEG Consultation on Voltage Quality Regulation in Europe Date: 22 February 2007 Distribution System Operator ESB Networks Page 1 of 12 Contents 1.0 INTRODUCTION...3
ACTIV-8 PLUS Insulated Conductor Bar
ACTIV-8 PLUS Insulated Conductor Bar A product made in Australia www.conductix.com.au ACTIV-8 PLUS ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It was designed by Conductix
The electrical energy produced at the gen
300 300 Principles of Power System CHAPTER CHAPTER 12 Distribution Systems General 12.1 Distribution System 12.2 Classification of Distribution Systems 12.3 A.C. Distribution 12.4 D.C. Distribution 12.5
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
FINAL. Alternative Evaluation. for the. Proposed Burlington-Wray 230-kilovolt Transmission Project
FINAL Alternative Evaluation for the Proposed Burlington-Wray 230-kilovolt Transmission Project Prepared by Tri-State Generation and Transmission Association, Inc. 1100 W. 116th Avenue Westminster, Colorado
AFRICAN DEVELOPMENT BANK
AFRICAN DEVELOPMENT BANK EMERGENCY POWER INFRASTRUCTURE REHABILITATION PROJECT - PHASE I SUPPLEMENTARY GRANT PROPOSAL COUNTRY : ZIMBABWE APPRAISAL REPORT ONEC DEPARTMENT December 2013 Table of Contents
HV Submarine Cable Systems Design, Testing and Installation
HV Submarine Cable Systems Design, Testing and Installation CIGRE Ireland Technical Seminar 6 th October 2010 Robert Donaghy Senior Consultant Engineer, ESB International Presentation Overview Applications
EEL303: Power Engineering I - Tutorial 4
1. Determine the voltage at the generating station and the efficiency of the following system (Figure 1): Both transformers have ratio of 2kV/11kV. The resistance on LV side of both Figure 1: transformers
ELECTRIC SCHEDULE LS-2 Sheet 1 CUSTOMER-OWNED STREET AND HIGHWAY LIGHTING
Revised Cal. P.U.C. Sheet No. 33883-E Cancelling Revised Cal. P.U.C. Sheet No. 28182-E ELECTRIC SCHEDULE LS-2 Sheet 1 APPLICABILITY: TERRITORY: RATES: This schedule is applicable to services for lighting
Security Systems Intrusion Alarm
Dufferin-Peel Catholic District School Board STANDARD TEXT GUIDELINE FOR Security Systems for SECONDARY AND ELEMENTARY SCHOOLS Prepared by the Plant Department With Assistance from Vision Dynamics Formatted
Electric Power Training Catalog
Open Enrollment & Contract Courses Online Training Customized Training Technical Assistance Electric Power Training Catalog Amp up your training! teex.org/electricpower TEEX Electric Power Training Since
TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT
TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.
Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants
Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants PG&E Office San Francisco January 18, 2007 Craig K. Meier Corrosion Control Incorporated Corrosion process for tanks
National Science Foundation Funds Request
University Corporation for Atmospheric Research National Science Foundation Funds Request 1. (NSF USE ONLY) 2. FACILITY NAME & LOCATION 3. PROJECT NAME 4. UCAR TRACKING NUM. NCAR Mesa Lab 15KV FEEDER REPLACEMENT
Financial Analysis of Solar Photovoltaic Power plant in India
Financial Analysis of Solar Photovoltaic Power plant in India M. Ganga Prasanna, S. Mahammed Sameer, G. Hemavathi Department of Management Studies MadanapalleInstitute of Technology& Science Post Box No:
A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS
A product made in Australia Insulated Conductor Rail ACTIV-8 PLUS ACTIV-8 PLUS The Industry Standard in Conductor Rails ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It
Q. Please provide resumes for Gary L. Murray, Sean LaCour, Glenn Samms, Trina L. Troke, Trina Cormier.
Requests for Information CA-47.0 NP NP 2007 CBA 1 2 3 4 5 6 Q. Please provide resumes for Gary L. Murray, Sean LaCour, Glenn Samms, Trina L. Troke, Trina Cormier. A. The resumes of Mr. Gary L. Murray,
ELECTRIC SERVICE HANDBOOK General Information Residential Service Portable/Standby Generators Temporary Service Commercial Service Metering
ELECTRIC SERVICE HANDBOOK General Information Residential Service Portable/Standby Generators Temporary Service Commercial Service Metering Requirements Clearance Requirements August 2015 A current version
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
Undergrounding high voltage electricity transmission. The technical issues
Undergrounding high voltage electricity transmission The technical issues This is an interactive PDF document with clickable links from the contents to all sections and back and also to URL and email links.
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
16 West Coast Regional Plan
16 West Coast Regional Plan 16.1 Regional overview 16.2 West Coast transmission system 16.3 West Coast demand 16.4 West Coast generation 16.5 West Coast significant maintenance work 16.6 Future West Coast
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
SECTOR ASSESSMENT (SUMMARY): ENERGY 1
Country Partnership Strategy: Uzbekistan 2012 2016 SECTOR ASSESSMENT (SUMMARY): ENERGY 1 Sector Road Map 1. Sector Performance, Problems, and Opportunities 1. The energy sector underpins Uzbekistan s sustained
Underground vs. Overhead Transmission and Distribution
electric power engineering Underground vs. Overhead Transmission and Distribution Your Power System Specialists June 9, 2009 1 NATIONAL TRENDS Municipalities have passed laws requiring new distribution
ENERGY NETWORKS ASSOCIATION. Electricity Industry EMF Measurement Protocol for High Field Areas
ENERGY NETWORKS ASSOCIATION Electricity Industry EMF Measurement Protocol for High Field Areas Contents 1 Introduction 1.1 Background 1.2 High Field Areas 2 High Field Area - Generation Businesses 2.1
Transmission Company Of Nigeria Project Management Unit. March, 2014
Transmission Company Of Nigeria Management Unit Status Report on On-going s Presentation to The Honourable Minister Of State For Power Mohammed Wakili March, 2014 World Bank Intervention in Energy Sector
STREETLIGHT SYSTEM GROUNDING AND BONDING
Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial