The most specified DPC and Cavity Tray Systems in the country
|
|
|
- Lucy Evans
- 9 years ago
- Views:
Transcription
1
2 2 HYLOAD DPC AND CAVITY TRAY SYSTEMS The most specified DPC and Cavity Tray Systems in the country Contents Page System elements 4 High Performance DPCs 5-9 Insulated DPCs Preformed Cloak Units Jointing systems Typical details Sitework Technical support 34 Supply and references 35 Hyload s DPC and Cavity Tray Systems encompass a complete family of high performance, specialist damp proofing products, each highly evolved for the job in hand, including insulated, gas and fire resistant systems. This extensive choice is further extended with valuable system accessories, from fixings, adhesives and jointing systems, to a wide range of standard and specially made preformed cloaks to ensure even the most complex architectural details are easily achieved. Hyload s DPC and Cavity Tray Systems also benefit from the unrivalled support of the structural waterproofing industry s leading design and technical services team, plus on-site technical support to ensure that you get more from the most specified damp proofing systems in the country. Peace of mind is reinforced by a brand portfolio that includes Hyload Original, which was the UK s first high performance polymeric DPC, and has been the recognised market leader for over 40 years. BS EN ISO 9000: 2000 Certificate Nos. Q05233, Q05244 Ruberoid Building Products Ruberoid is the UK s leading manufacturer and supplier of high performance waterproofing and roofing systems and a division of IKO PLC, a member of the IKO Group - one of the world s foremost specialists in bituminous waterproofing. The Ruberoid name has been synonymous with high quality damp-proofing, tanking membranes and weather protection products for over years. We have built our reputation through close working partnerships with specifiers, contractors and clients in both the public and private sector, on a wide variety of new build and refurbishment projects. Ruberoid has always led the field in the development and production of waterproofing membranes and damp proof courses, consistently setting levels of product performance that have subsequently become industry standards. Ruberoid was the first manufacturer in its field to gain quality accreditation to BS EN ISO 9000: 2000 (formerly BS 5750). Housing and commercial development, West One, Sheffield Architect: Carey Jones
3 HYLOAD DPC AND CAVITY TRAY SYSTEMS 3 The penetration of water into the fabric of a building has serious consequences for the health of the occupants and for the long term serviceability of the structure... By their nature, masonry walls are not waterproof. BS 5628: Part 3: 2001, section 5.5
4 4 HYLOAD DPC AND CAVITY TRAY SYSTEMS Total damp-proofing design... All the products detailed on the following pages form part of complete DPC systems, comprising: the DPC which can be easily formed to create a cavity tray standard and special Preformed Cloak Units which simplify the damp-proofing of awkward junctions and eliminate leakage paths Hyload DPC Lap Adhesive Hyload DPC Jointing Tape Hyload DPC Mastic Hyload DPC Joint Support System the Ruberoid range of insulated, fire resistant and gas resistant DPCs and Cavity Closures. These DPC systems combine with the Synthaprufe range of liquid products, the Plasprufe range of self adhesive and torch applied tanking systems, and the Gastite range of membranes, to provide fully integrated solutions to damp proofing and tanking problems. A separate Tanking Systems Design Guide is available. Insulated and Fire DPCs Pages Preformed Cloak Units Pages DPCs Pages 5-9 Jointing Systems Pages Lingham Court apartments, London SW9 Architect: Pollard Thomas Edwards
5 HYLOAD DPC AND CAVITY TRAY SYSTEMS 5...to full technical support Our principle goal is to make life easier for the specifier and contractor by taking responsibility for the design and manufacture of all DPC and cavity tray systems, providing a bespoke and complete solution for every project. Ruberoid s dedicated structural waterproofing technical services team provide NBS specifications, take-off schedules, detailed 3D drawings and location plans, whilst our national team of project managers also provide on-site technical and installation support, for complete peace of mind. Ruberoid subscribes to NBS Plus, which is an electronic library of technical details and guidance notes. NBS clauses allow the accurate and easy completion of specifications relative to manufacturers proprietary products. Ruberoid also offers RIBA-approved CPD seminars for above and below ground waterproofing. To find out more about these seminars please contact us on Tel: The Hyload brand Hyload Original was the UK s first high performance polymeric DPC, and was also awarded the first Agrément Certificate back in It has been the recognised market leader providing damp-proofing security for over 40 years, without a single reported material failure. Innovations in technology and manufacturing techniques have led to the development of an extensive choice of DPCs and fixing systems which bear the Hyload name. Ruberoid has also developed other DPC systems to meet the latest fire and thermal building requirements, and to ensure that all architectural specifications can be achieved. Standards and authority Hyload Original and Hyload MortarMatch hold British Board of Agrément Certificate number 95/3133, which also includes Preformed Units and the Hyload DPC Jointing System. Hyload HouseBuilder holds British Board of Agrément Certificate number 97/3403. Permabit holds British Board of Agrément Certificate number 88/1966, which also includes the Preformed Units and DPC Jointing System. Hyload Insulated DPC (Ruberclose) holds British Board of Agrément Certificate number 97/3310. Hyload FR Insulated DPC (Ruberclose FR) holds British Board of Agrément Certificate number 97/3310.
6 6 HYLOAD DPC AND CAVITY TRAY SYSTEMS DPC selection by application This table is designed as a guide to assist the specifier in identifying the appropriate DPC for typical applications. Where specific project details are not covered, please contact Ruberoid s Structural Waterproofing Design Service for further information. Ruberoid s recommendations for typical applications are based upon one or all of the following key DPC performance criteria: Ability to adhere to mortar Membrane colour Durability Flexibility Resistance to loading Thermal efficiency Fire resistance Gas resistance All products can be recommended, but the products indicated in orange have been specially developed for the application Damp proof course or cavity tray for residential dwellings up to three storeys high Hyload HouseBuilder* Hyload MortarMatch Permabit Hyload Original Gastite Pluvex The traditional Pluvex products conforming to BS 6398 have been largely superseded by Hyload HouseBuilder which is superior with regards to flexibility in cold weather and ease of use on site. Hyload HouseBuilder forms part of a system so that when used as a supported cavity tray, joints are sealed using Hyload DPC Lap Adhesive or Hyload DPC Jointing Tape. *Not to be used as an unsupported cavity tray or in residential constructions in excess of three storeys. Damp proof course only. Not to be used as a cavity tray. Damp proof course or cavity tray for commercial or residential developments up to fifteen storeys high Hyload Original Hyload MortarMatch Permabit Hyload HouseBuilder* Gastite Hyload Original DPC has been waterproofing buildings for over 40 years. The name Hyload has become synonymous with the requirements for a robust, flexible, general purpose DPC that will not extrude under load. It conforms to the selection criteria of BS 5628 and BS 8215 and forms part of a complete system so that when used as a cavity tray, joints are fully supported and sealed, and awkward junctions such as internal and external corners are waterproofed with preformed cloak units. *Not to be used as an unsupported cavity tray or in residential constructions in excess of three storeys. Damp proof course or cavity tray below copings, in parapet walls or free-standing walls Permabit Hyload MortarMatch Hyload Original Permabit DPC is specifically developed for lightly loaded parts of the construction such as beneath copings or as a cavity tray in parapet walls. This high bond strength DPC has exceptionally good adhesion to mortar. Permabit forms part of a complete system so that when used as a cavity tray, joints are fully supported and sealed, and awkward junctions such as internal and external corners are waterproofed with preformed cloak units.
7 HYLOAD DPC AND CAVITY TRAY SYSTEMS 7 Damp proof course or cavity tray matched to stonework and/or mortar Hyload MortarMatch Hyload MortarMatch DPC is colour matched to the external skin of the construction. The standard colours of brown and white greatly reduce the visual impact of the DPC projection from the mortar joint. Hyload MortarMatch forms part of a complete system so that when used as a cavity tray, joints are fully supported and sealed, and awkward junctions such as internal and external corners are waterproofed with colour matched preformed cloak units. Damp proof course or cavity tray resistant to methane, radon and other ground gases Gastite Hyload MortarMatch* Permabit* Hyload Original* Hyload HouseBuilder* Gastite DPC is specifically developed to resist the passage of all ground gases and is used in conjunction with either loose laid or bonded Gastite DPMs. It is commonly used as a horizontal DPC bridging the wall construction thereby preventing the movement of gases up through the cavity. A cavity tray is positioned immediately above the Gastite DPC. For total gas resistance, use Gastite DPC in conjunction with Gastite DPM or Gastite LL. * Radon gases only Insulated DPCs for windows and doors Hyload Insulated DPC/ Hyload FR Insulated DPC Hyload DPC allows structural openings to meet Building Regulations with regards thermal efficiency. Sandwiched between the internal and external masonry units at window and door reveals, Hyload Insulated DPC prevents the occurrence of cold bridging. Hyload FR Insulated DPC meets the requirements of the Scottish Building Regulations. Where fire resistance is a requirement, Hyload FR Insulated DPC achieves a minimum 30 minutes fire resistance.
8 8 HYLOAD DPC AND CAVITY TRAY SYSTEMS High Performance DPCs Innovations in technology and manufacturing techniques have led to the development of an extensive choice of DPCs and fixing systems which bear the Hyload name. Hyload Original A polymeric DPC which is suitable for providing damp-proofing and the formation of cavity trays in all applications. Hyload Original will not extrude under load. Hyload Original was the first high performance polymeric DPC membrane in the UK, and was awarded the first ever Agrément Certificate in Hyload Original has been providing dampproofing security for over 40 years, without a single reported system failure. Permabit Hyload Original Certificate No. 95/3133 A superior performance bitumen polymer DPC, specifically designed to provide excellent adhesion to mortar. Permabit will not compress, even under the heaviest of wall loadings. Permabit Certificate No. 88/1966 Hyload MortarMatch A high performance, polymeric DPC, designed to further enhance the advantageous characteristics of Hyload Original. The membrane is pigmented to match typical mortar colouration, and therefore is significantly less conspicuous in situ than black DPCs, at the same time offering a more durable material, with increased mortar adhesion. Bespoke Hyload MortarMatch DPCs are also available to match particular regional or historic building requirements. Hyload MortarMatch Certificate No. 95/3133 Hyload HouseBuilder A polymeric DPC specifically designed to provide long-term damp proofing for housing applications, and specifically offered to provide the housebuilder with a high performance cost effective alternative to traditional bitumen DPCs. Hyload HouseBuilder has not been assessed unsupported across cavity constructions, and as such is not recommended as an unsupported cavity tray. Hyload HouseBuilder utilises the same proven production technology of Hyload Original. Gastite Formulated to provide a reliable and effective barrier against the transmission of radon, methane and other gases and used in conjunction with Gastite loose laid DPM or Gastite self-adhesive DPM/tanking membrane. This polyester-reinforced damp proof course incorporates a 50 micron aluminium core and is coated in flexible rubber modified bitumen. Other Ruberoid DPCs Hyload insulated DPC (Ruberclose) has been developed to minimise cold bridging when closing masonry cavity walls around openings (see page 10). Hyload FR insulated DPC (Ruberclose FR) offers thermal effectiveness with the added security of fire resistance (see page 10). Ruberoid also supplies a range of fire rated Structural Cavity Closures as well as the Pluvex range of domestic grade (BS 6398) DPCs. For further information refer to specific data sheets. Hyload HouseBuilder Certificate No. 97/3403
9 HYLOAD DPC AND CAVITY TRAY SYSTEMS 9 Product features Hyload Original Over 40 years proven reliability Excellent performance under high compressive loads Good flexibility at low temperatures Tough and durable Permabit Excellent mortar adhesion properties Over 25 years proven reliability Excellent performance under both high and low compressive loads Tough and durable with excellent flexibility Hyload MortarMatch Mortar colour-matched: Standard Brown and White Substantially greater tensile strength and elongation Improved tear strength Improved puncture resistance Improved flexibility Hyload HouseBuilder Specifically designed for housing No extrusion under heavy loads Usable under concrete floor beams Offers superior performance to traditional British Standard DPCs. Gastite Effective against gas permeation. Good product flexibility and tolerance at low temperatures. Formulated to provide a reliable and effective barrier against the transmission of radon, methane and other gases and used in conjunction with Gastite DPM or Gastite LL. Dimensions and weight Hyload Permabit Hyload Hyload Gastite MortarMatch Original HouseBuilder Nominal weight (kg/m 2 ) Nominal thickness (mm) Nominal length (m/roll) Standard widths (nominal) Roll width * 900* 0* m 2 roll Non-standard widths are available to order in 25 mm increments. *Non-standard widths for Hyload HouseBuilder. Summary of technical data Hyload Permabit Hyload Hyload Gastite MortarMatch Original HouseBuilder Permeability to water vapour (Refer to Gastite to BS 3177 (g/m over 24 hours) data sheet) Tensile strength at break to BS 2782, MD = 10.9 MD = 5.1 MD = 8.8 MD = A at mm/minute (N/mm 2 ) CD = 9.3 CD = 4.7 CD = 6.9 CD = 6.9 Elongation at break to BS 2782, MD = 245 MD = 510 MD = 200 MD = A at mm/minute (%) CD = 260 CD = 490 CD = 190 CD = 190 Tear strength TO BS 2782, 360B MD = 39.0 MD = 64.1 MD = 33.0 MD = 34.0 at mm/minute (N/mm 2 ) CD = 41.0 CD = 58.8 CD = 42.0 CD = 42.0 Static indentation with 24 kg for 24 hours to MOAT 27, Satisfactory Satisfactory Satisfactory Satisfactory Dynamic indentation with 12 mm punch to MOAT 27, Satisfactory Satisfactory Satisfactory Satisfactory Low temperature flexibility at 30 C to BS 747, Appendix C4 Pass Pass Pass Pass MD = machine direction (longitudinal) CD = cross direction (transverse) Note: Figures shown are typical test method results and should not be used for specifying purposes
10 10 HYLOAD DPC AND CAVITY TRAY SYSTEMS Insulated DPCs Insulated DPCs to minimise cold bridging The use of Hyload Insulated DPCs enable the cavity to be closed in the traditional way, while conforming to the latest thermal and cold bridging requirements of the Building Regulations Approved Document L, NHBC, and BRE guidelines Thermal insulation: avoiding risks. Hyload Insulated DPC Hyload Insulated DPC (Ruberclose) will minimise cold bridging when within closing structures in masonry cavity walls around openings. The use of insulated DPC enables the cavity to be closed in the traditional way, while conforming to the requirements of Building Regulations Approved Document L and new Robust Details Document. Hyload Insulated DPC also conforms to the requirement of NHBC and BRE guidelines Thermal insulation: avoiding risks. Hyload Insulated DPC is specifically designed for application at window and door locations. However, it may also be used to insulate and waterproof structural interfaces where, for example, an internal wall meets an external wall and a cold bridge exists. Hyload FR Insulated DPC Hyload FR Insulated DPC (Ruberclose FR) is a fire retardant insulated DPC, which will minimise cold bridging when closing masonry cavity walls around openings, whilst meeting current and proposed fire regulations in England, Scotland and Wales. In addition Ruberclose FR also meets the requirements of Approved Document L of the Building Insulated DPC Regulations (England and Wales) and of Part J (Appendix B) of the Technical Standards of the Building Regulations (Scotland) to prevent surface condensation and mould growth and to avoid additional heat losses at the edges of openings. Ruberclose and Ruberclose FR Certificate No. 97/3310 Insulated DPC Preformed Cloak Unit
11 HYLOAD DPC AND CAVITY TRAY SYSTEMS 11 Product features Hyload Insulated DPC - Ruberclose Superior Thermal Resistance BBA Approval, Agrément Certificate No.97/3310 Flexible High Performance DPC superior to polyethylene DPC Insulation remains flexible when bent and will not crack Uniformly maintains thermal properties and does not allow thermal leakage Exceptionally easy to handle Non standard sizes available Hyload FR Insulated DPC - Ruberclose FR Superior Thermal Resistance BBA Approval Tough, flexible, high performance DPC covered by Agrément Certificate No. 97/3310 Phenolic foam insulation offering: Excellent resistance to burning and the spread of flame. Almost complete absence of smoke when subjected to a flame. High closed cell content and fine cell structure. Good resistance to moisture penetration and no wicking. The lowest thermal conductivity of any commonly available insulation material, including mineral wool. Environmentally friendly - CFC free Safe and easy to install: Easy to cut Lightweight and rigid - easy to position Non standard sizes available Dimensions Hyload Insulated DPC - Ruberclose is supplied in 8 m rolls DPC roll size Insulation width Selvedge (mm) and thickness (mm) width 8 m x 165 x mm 8 m x 180 x mm 8 m x x mm Note: The DPC extends on either side of the insulation. To comply with Codes of Practice requirements, where more than one length is installed, the insulation must be trimmed back on-site mm from one end. Hyload FR is available in 1300 mm lengths of which the insulation length is 1200 mm DPC width Insulation width Units Selvedge (mm) and thickness (mm) per pack width 165 x lengths 32.5 mm 180 x lengths 40 mm x lengths 42.5 mm Note: Thicknesses of Phenolic Insulation at 30 mm, and 40 mm are available on request as specials supplied in 1200 mm lengths bonded to 1300 mm DPC. Please contact our Structural Waterproofing Design Service for price and availability. The DPC extends 32.5 mm or 40 mm on either side of the insulation and mm at one end. This allows the DPC to contact the window/door frame and to extend the required amount into the cavity. The extension of DPC at one end allows vertical connection and lapping. If necessary the insulation can be easily trimmed back on site mm from the end of the DPC. Performance Thermal properties Hyload Insulated DPC Hyload FR Insulated DPC k (λ) value (W/mK) R value (m 2 K/W)
12 12 HYLOAD DPC AND CAVITY TRAY SYSTEMS Preformed Cloak Units To comply with current British Standard recommendations BS 5628: Part 3: 2001, clause :... preformed cloaks should be specified so as to restrict the site operation to simple jointing only. Ruberoid s Structural Waterproofing Design Service can assist with the development of the details for inclusion within the tender document. Description Preformed Cloak Units are fabricated from specially formulated sheet material which is a blend of synthetic polymers. Preformed Cloak Units simplify the damp-proofing of awkward junctions and eliminate leakage paths. Certain architectural details are impossible to damp-proof efficiently by site forming of strip materials or even leadworking. Preformed Cloak Units are available to overcome complex shapes and changes in direction, saving potential problems and costly remedial works on site. The standard built in cloak units shown opposite, are designed to accommodate 50, 75 or mm cavity widths and a 150 or 225 mm rise in the cavity tray. The standard surface fixed cloak units are designed for these same cavity widths and for a 150 mm rise in the cavity tray. The Structural Waterproofing Design Service provides free of charge design support to specifiers, producing special or project specific Preformed Cloak Units. Product features Enable the designer and installer to comply with BS 5628: Part 3: 2001 Factory manufactured and quality inspected Effective and reliable waterproofing solution for awkward junctions Speeds up DPC installation and helps to reduce costs Fully compatible with all Ruberoid DPC products Dedicated free design service readily available to locate and detail special (project specific) Preformed Cloak Units. Type 5 Cloak Unit Jamb Cloak Type 3 Cloak Unit Pipe Cloaks
13 HYLOAD DPC AND CAVITY TRAY SYSTEMS 13 Standard Preformed Cloak Units Type 1 Change of level unit (brick/block) Reversible Product code Cavity Step on face rise/width (mm) / / / / / /150 Step on face 225/75 50/75/ / / / Type 2 Change of level unit (surface fixed) Product code Cavity Step on face rise/width (mm) RH 150/ LH 150/ RH 150/ LH 150/ RH 150/ LH 150/ RH 150/ /75/ 75/225 step on face LH 150/ Right hand unit shown RH 150/ LH 150/ RH 150/ LH 150/ 225 Type 3 Stop end (brick/block or surface fixed) Product code Cavity rise/width (mm) RH 150/ LH 150/ RH 150/75 150/ /75/ Right hand unit shown LH 150/ RH 150/ LH 150/ RH 225/ LH 225/ RH 225/ LH 225/ RH 225/ LH 225/ 150/ /75/ Right hand unit shown
14 14 HYLOAD DPC AND CAVITY TRAY SYSTEMS Standard Preformed Cloak Units (continued) Type 5 Internal corner (surface fixed) Product code Cavity rise/width (mm) / / / /75/ Type 6 External corner (surface fixed) Product code Cavity rise/width (mm) / /75/ / / Type 7 Internal/external corner (brick/block) Product code Cavity rise/width (mm) / /75 225/ / / /75 50/75/ Internal / 225/150 50/75/ External
15 HYLOAD DPC AND CAVITY TRAY SYSTEMS 15 Type 8 Internal corner Reversible Product code Type 8S Angled stop end (right or left hand) Product code Cavity width (mm) RH LH RH LH RH LH 60 50/75/ Type 9 External corner Product code Type 10 Column stop end (brick/block or surface fixed) Product code Cavity rise/width (mm) RH 150/ LH 150/ RH 150/ LH 150/ RH 150/ LH 150/ 225/ RH 225/ LH 225/50 50/75/ RH 225/ LH 225/ RH 225/ LH 225/
16 16 HYLOAD DPC AND CAVITY TRAY SYSTEMS Jointing Systems Simplifies installation and fully supports DPC joints BS 5628: Part 3: 2001, clause : Cavity trays should be supported at their joint positions to facilitate effective sealing. BS 8215: 1991, clause 5.5:... joints should be fully supported, well-lapped and sealed. Hyload DPC Joint Support System Ruberoid in recognising the practical difficulties in jointing cavity trays have introduced the Hyload DPC Joint Support System. This enables contractors to make effective and waterproof joints between DPCs, cavity trays and Preformed Cloak Units. The system works by providing rigid support across the cavity allowing pressure to be applied to effect a waterproof joint. The Hyload DPC Joint Support System consists of a 350 x 200 mm reinforced support of twin walled polypropylene with a mm self adhesive strip protected by silicone release paper bonded centrally to its upper surface. Joints are formed by means of a mm wide self adhesive tape protected on both sides by silicone release paper. The Hyload DPC Joint Support System is a patented system and available only from Ruberoid. Product features DPC joint fully supported Product enables designer and installer to comply with current best practice Provides a watertight joint Improves installation procedures helping to reduce overall costs Application of Hyload DPC Joint Support System 1 Joint support prior to bedding mm on each leaf 2 Fold edges to rest on brickwork/blockwork. Where the board locates on the external leaf, fold the two 40 mm x 50 mm side flaps to locate down the inside face of the outer skin. The board will now be tightly retained against the outer masonry. 3 Position joint support at point where DPC lap joint will occur. Remove central silicone release paper and push DPC firmly in place
17 HYLOAD DPC AND CAVITY TRAY SYSTEMS 17 Hyload DPC Fixing Strip The Fixing Strip is a semi-rigid plastic strip 25 mm x 3 mm x 2 m pre-drilled at 150 mm centres. It is used where surface fixing any Ruberoid high performance DPC to the inner leaf. Hyload DPC Fixing Pins for Masonry Hyload DPC Jointing Tape on Ruberoid Self-Adhesive Primer. Alternatively Hyload DPC Mastic can be used Hyload DPC Fixing Pins Used with Hyload DPC Fixing Strip, Hyload DPC Fixing Pins for Masonry can be used for surface fixing to solid internal substrates such as blockwork, stone and concrete. Hyload DPC Fixing Strip Composite inner skins require Hyload DPC Fixing Pins for Insulation to ensure correct fixing (see page 30). Hyload DPC Fixing Pins are: Corrosion resistant Quick and easy to install Complements Hyload DPC Fixing Strip Ruberoid High Performance DPC formed to create surface fixed cavity tray 4 Apply a strip of Hyload DPC jointing tape to the DPC 5 Remove top silicone release paper and immediately lap and bond DPC 6 Supported and watertight mm wide joint
18 18 HYLOAD DPC AND CAVITY TRAY SYSTEMS Jointing Systems (continued) Hyload DPC Lap Adhesive A synthetic rubber/resin mixture supplied in 500 ml cans. It is suitable for bonding DPC to DPC, and DPC to Preformed Cloak Units. Before use, ensure that surfaces to be bonded are clean and dry. Apply Hyload DPC Lap Adhesive to both surfaces and allow to dry. Bring surfaces together and apply firm pressure to create a permanent bond. One 500 ml can gives coverage of approximately 3 m 2 (1.5 m 2 of bonded area). Hyload DPC Jointing Tape A double sided self adhesive bituminous tape, 10 m x mm, for bonding DPC to DPC, and DPC to Preformed Cloak Units. Before use, ensure that surfaces to be bonded are clean and dry. Removal of release films reveals self adhesive surfaces. Apply firm pressure to create a permanent bond. Hyload DPC Mastic A thick synthetic rubber mastic adhesive with gap filling properties up to 6 mm suitable for bonding Ruberoid high performance DPCs and Preformed Cloak Units to a wide range of common building materials. No primer is required. Hyload DPC Mastic is applied to one surface only. Apply firm pressure to create a permanent bond. For vertical DPC applications, the Hyload DPC Fixing Strip and Pins must be used. Typical coverage on smooth surfaces 1.2 to 2 m 2 per litre. Ruberflex Sealant Ruberflex is a one-part bitumen modified synthetic rubber sealant. The product is suitable for application to bituminous substrates as well as other common building materials. It is commonly used to seal penetrations in cavity trays caused by wall ties. Speed and simplicity of application Resistant to alkalis, dilute acids and de-icing salts Remains flexible over a wide temperature range Excellent adhesion Impermeable to water Ruberoid Self-Adhesive Primer A rubber modified bituminous primer for the preparation of substrates prior to the application of self-adhesive products. Typical coverage 4-6m 2 per litre. Ruberoid Copeclose A tough flexible polymeric cavity closure ideal for closing cavities and supporting Ruberoid High Performance DPC s below copings and parapets. Ruberoid Permabit DPC Flexible, allowing ease of handling on site Available in standard 180 mm x 1 metre lengths Non-standard sizes available on request Excellent puncture resistance Easy to cut and shape on site Ruberoid Copeclose to project 40 mm on to brickwork Lingham Court apartments, London SW9 Architect: Pollard Thomas Edwards
19 HYLOAD DPC AND CAVITY TRAY SYSTEMS 19
20 20 HYLOAD DPC AND CAVITY TRAY SYSTEMS Typical details Change of ground level Hyload DPC Jointing Tape on Ruberoid Self Adhesive Primer. Alternatively Hyload DPC Mastic can be used Ruberoid Hyload DPC Fixing Strip and Pins Ruberoid Column Preformed Cloak Unit (supplied in two parts to suit column width) Ruberoid High Performance DPC Ruberoid Type 1 Preformed Cloak Unit and Hyload DPC Jointing System Ruberoid High Performance DPC Ruberoid High Performance DPC DPC/DPM link DPM DPC/DPM Joint sealed with Hyload DPC Jointing Tape
21 HYLOAD DPC AND CAVITY TRAY SYSTEMS 21 Concrete wall tanking/dpc link detail Ruberoid High Performance DPC Ruberoid Plasprufe 2000SA membrane Cavity fill Ruberoid Self-Adhesive Primer Hyload DPC Jointing Tape on Ruberoid Self Adhesive Primer Ruberoid High Performance DPC Hyload DPC Jointing Tape Ruberoid Self Adhesive Primer Ruberoid Plasprufe Protection Board Ruberoid Plasprufe 2000SA membrane Ruberoid Column Preformed Cloak Unit Hyload DPC Mastic Hyload DPC Jointing System Steel column Ruberoid High Performance DPC DPCs must project 5 mm beyond the external face and must be bedded on both faces with mortar. All joints between lengths of DPC, and DPC and Preformed Cloak Units must be lapped a minimum of mm and bonded with Hyload DPC Lap Adhesive or Hyload DPC Jointing Tape. The cavity tray should step down or slope across the cavity not less than 150 mm towards the external leaf. Insulation omitted for clarity.
22 22 HYLOAD DPC AND CAVITY TRAY SYSTEMS Typical details (continued) Ramped access BS 8300: 2001, clause 5.8 states that wherever possible the approach to a building is level. If a change of level is unavoidable, it will be necessary to provide a sloped surface. Ruberoid Ruberclose Ruberoid High Performance Cavity Tray Special Preformed Cloak Unit Ruberoid High Performance horizontal DPC Ruberoid Plasprufe Membrane (DPM) Internal view Ruberoid Ruberclose Ruberoid High Performance DPC to blockwork Special Preformed Cloak Unit mm lap joint fully sealed with Ruberoid Hyload DPC Jointing Tape Ruberoid Plasprufe Membrane (DPM)
23 HYLOAD DPC AND CAVITY TRAY SYSTEMS 23 Protection against ground gases Hyload Original or Permabit DPC cavity tray DPCs must project 5 mm beyond the external face and must be bedded on both faces with mortar. All joints between lengths of DPC, and DPC and Preformed Cloak Units must be lapped a minimum of mm and bonded with Hyload DPC Lap Adhesive or Hyload DPC Jointing Tape. The cavity tray should step down or slope across the cavity not less than 150 mm towards the external leaf. Insulation omitted for clarity. Gastite DPC supported across the cavity Gastite DPM or Gastite LL Typical horizontal movement joint Typical vertical movement joint Ruberoid recommends where ever possible that DPCs do not span vertical movement joints. Ruberoid High Performance DPC Ruberoid Type 3 Preformed Cloak Unit
24 24 HYLOAD DPC AND CAVITY TRAY SYSTEMS Typical details (continued) Ruberoid Type 3 Preformed Cloak Unit Window opening Ruberoid Type 8 Preformed Cloak Unit Every third perpend to be open Ruberoid Ruberclose Insulated DPC to jamb must locate beneath proprietary lintel support and dress into sill cavity tray Ruberoid Type 8S Preformed Cloak Unit
25 HYLOAD DPC AND CAVITY TRAY SYSTEMS 25 Hyload DPC Fixing Strip and Fixing Pins for Masonry Window arch Ruberoid Arch Preformed Cloak Unit Hyload DPC Jointing Tape on Ruberoid Self-Adhesive Primer, alternatively Hyload DPC mastic can be used DPCs must project 5 mm beyond the external face and must be bedded on both faces with mortar. All joints between lengths of DPC, and DPC and Preformed Cloak Units must be lapped a minimum of mm and bonded with Hyload DPC Lap Adhesive or Hyload DPC Jointing Tape. The cavity tray should step down or slope across the cavity not less than 150 mm towards the external leaf. Insulation omitted for clarity.
26 26 HYLOAD DPC AND CAVITY TRAY SYSTEMS Typical details (continued) Circular window/stone Ruberoid Type 3 Preformed Cloak Unit Every third perpend to be open Ruberoid Ruberclose (Special) Ruberoid Type 3 Preformed Cloak Unit Every third perpend to be open
27 HYLOAD DPC AND CAVITY TRAY SYSTEMS 27 Column detail/stone Hyload DPC Fixing Strip and Fixing Pins for Masonry Ruberoid Preformed Cloak Unit Hyload MortarMatch DPC formed to create cavity tray A small bead of Ruberoid Ruberflex Sealant can be applied around the dowel. Extreme care should be taken to avoid any future staining Intermediate concrete floor/stone Hyload MortarMatch DPC formed to create cavity tray DPCs must project 5 mm beyond the external face and must be bedded on both faces with mortar. All joints between lengths of DPC, and DPC and Preformed Cloak Units must be lapped a minimum of mm and bonded with Hyload DPC Lap Adhesive or Hyload DPC Jointing Tape. The cavity tray should step down or slope across the cavity not less than 150 mm towards the external leaf. Insulation omitted for clarity.
28 28 HYLOAD DPC AND CAVITY TRAY SYSTEMS Typical details (continued) Parapet - gable pitched roof Coping stone dowels not shown for clarity. To ensure waterproofing integrity, where fixings penetrate DPC, apply a small bead of Ruberoid Ruberflex Sealant around dowels. Ruberoid Permabit DPC under coping system to be lapped and bonded with Hyload DPC Jointing Tape Ruberoid Rubershield-Pro turned up wall by at least mm Insulation board Ruberoid Copeclose Vapour Control Layer Note: Ibstock recommends the use of bitumen polymer DPCs in parapet walls using their copings. Parapet with coping Ruberoid Permabit DPC Ruberoid Copeclose Ruberoid Ultra prevent High Performance elastomeric roofing system Ruberoid High Performance DPC
29 HYLOAD DPC AND CAVITY TRAY SYSTEMS 29 Pitched roof abutment Soakers to suit roof covering and lead flashing to be installed in the traditional manner. Weep holes at 1 metre maximum centres or at least one per cavity tray. DPCs must project 5 mm beyond the external face and must be bedded on both faces with mortar. All joints must be lapped a minimum of mm and bonded with Hyload DPC Lap Adhesive or Hyload DPC Jointing Tape. The cavity tray should step down or slope across the cavity not less than 150 mm towards the external leaf. Insulation omitted for clarity. Preformed Roof Abutment Cloak (Left hand side) Preformed Roof Abutment Cloak (Right hand side) Roof line Hyload DPC Mastic Hyload DPC Fixing Strip and Fixing Pins for Masonry All laps sealed with Hyload DPC Jointing Tape Preformed Stop End Cloak (Left hand side) Preformed Roof Abutment Cloak (Left hand side)
30 30 HYLOAD DPC AND CAVITY TRAY SYSTEMS Typical details (continued) DPC to composite inner skin Vertical stud Ruberoid Hyload DPC Fixing Strip and Fixing Pins for Insulation (Hyload DPC Fixing Pins for Insulation, code ) Rigid insulation Ruberoid Hyload DPC Mastic Ruberoid Rubershield-PRO breather membrane Fixing channel for wall ties Ruberoid High Performance DPC Stud frame Ruberoid High Performance DPC Plasprufe 3HD membrane loose laid on sand or sand/cement blinding Plasprufe 3 membrane
31 HYLOAD DPC AND CAVITY TRAY SYSTEMS 31 Ruberoid Synthaprufe LAC for vapour and air resistance to inner fabric Protection to structurally clad unit Note: Cladding Systems Limited recommends the use of Synthraprufe LAC in conjunction with their cladding products. Cladding by Cladding Systems Limited or similar Wind post Steel wind post Preformed Wind Post Cloak Unit Insulation Cloak bonded with Hyload DPC Mastic DPCs must project 5 mm beyond the external face and must be bedded on both faces with mortar. All joints between lengths of DPC, and DPC and Preformed Cloak Units must be lapped a minimum of mm and bonded with Hyload DPC Lap Adhesive or Hyload DPC Jointing Tape. The cavity tray should step down or slope across the cavity not less than 150 mm towards the external leaf. Insulation omitted for clarity.
32 32 HYLOAD DPC AND CAVITY TRAY SYSTEMS Sitework Delivery to site Hyload high performance DPCs are delivered to site in rolls, secured with a paper wrapper. On delivery it is important to check compliance of materials with specification requirements. Handling and storage Rolls must be stored level, on end and under cover. Care must be taken to ensure that DPCs are not contaminated by hydrocarbon or other organic solvents. Ruberoid s instructions regarding handling and storage must at all times be followed. Standard Preformed Cloak Units are supplied in cardboard cartons. Installation of DPCs Installation must follow normal good practice for the detailing of damp proof courses, as set out in the relevant clauses of BS 5628: Part 3: 2001, BS 8000: Part 3: 2001 and BS 8215: 1991, and must be in accordance with Ruberoid s instructions. The following installation practices are essential: 1. DPCs must extend through the full thickness of the wall or wall leaf, including pointing, applied rendering or other facing material and project beyond the external face by 5 mm. 2. DPCs must be laid between even beds of wet mortar, and perforations in adjacent courses of brickwork must be completely filled with mortar. 3. All lap joints in the DPC must have a fully supported mm overlap and be completely sealed. 4. Ruberoid Preformed Cloak Units must be used at stop ends, and all corners and changes in level of cavity trays. Product data sheets may provide additional installation information and should be consulted. Data sheets are available from the Ruberoid website or by phoning the technical hotline. Lap joints All surfaces to be jointed should be clean and dry. Release paper protecting the self adhesive strips should not be removed until the joint is ready to be formed. When the jointing system is used during low temperatures, gentle warming of the self adhesive may be necessary. When forming a lap joint using the support unit and self adhesive tape, the manufacturer s instructions should be followed. The joint support board should be fitted in such a way as to span the cavity, the ends of the support unit being bent so far as to bear upon the inner and outer leaves of the wall for a distance of between 25 mm and 40 mm. If necessary the support unit may be temporarily fixed in place. The first layer of cavity tray or preformed cloak unit to be joined should be offered up to the joint support board. The release film should be removed from the adhesive strip and, by application of uniform pressure the cavity tray or preformed cloak unit bonded to it. A strip of self adhesive tape should then be applied to the upper surface of the cavity tray or preformed cloak unit over the area supported by the joint support board. The upper silicone release paper should be removed and the joint formed ensuring that a full seal is achieved. Surface/face fixing Where the cavity tray or Preformed Cloak Unit is required to be surface fixed to a brick, block, concrete or composite inner skin, the vertical portion should be held in place by either Hyload DPC Jointing Tape (the substrate having been previously primed with Ruberoid Self Adhesive Primer, or alternatively Hyload DPC Mastic, which does not require a primer). Hyload DPC Fixing Strip must then be installed using appropriate Hyload DPC Fixing Pins, to provide a permanent mechanical fixing. Fixing Pins for masonry Drill a clearance hole 6 mm diameter by 45 mm deep into the substrate. Insert the Fixing Pin into the hole. Tap the pin firmly home using a flat faced hammer. The barbed portion of the Fixing Pin will expand giving a secure grip and high pull-out resistance. Fixing Pins for insulation Using a tool such as a bradawl, form a pilot hole through the DPC prior to inserting the push-fit Fixing Pin. The fir-tree portion of the Fixing Pin will securely locate into the insulation of composite inner skins. Cleaning of cavities As with all other damp proof course materials, damage can occur during cleaning of mortar droppings from the cavity unless care is taken. The following recommendations should prevent damage occurring: 1. Cavity battens should be used to prevent excessive mortar droppings reaching the damp proof course. 2. Mortar droppings should be removed before they have had time to harden. 3. Implements such as steel rods should never be used for cleaning. 4. Damp proof courses should be examined for damage as work proceeds.
33 HYLOAD DPC AND CAVITY TRAY SYSTEMS 33 Laying Preformed Cloak Units Ruberoid Preformed Cloak Units should be laid as follows. A Type 7 Preformed Cloak Unit is used as an example. 1. An even bed of mortar should be applied to both leaves of the wall and the Preformed Unit placed firmly into position. 2. Lay the first run of cavity tray and bond firmly to the Preformed Cloak Unit allowing a minimum mm overlap. A Hyload DPC Joint Support should be used at the junction. 3. Lay the second run of cavity tray as above. After installation, the next brick/block course should be laid immediately on a bed of wet mortar and the joint finished to normal thickness. 1 Ruberoid Insulated DPCs Handling Ruberoid Insulated DPCs require no special handling. However, excessive physical action can cause delamination of the insulation and should be avoided. Installation Installation must follow good practice for the detailing of damp proof courses (refer to BS 5628: Part 3: 2001, BS 8215: 1991 and BS 8000: Parts 3 and 4, and in accordance with the manufacturer s instructions. In particular, the following practices are essential: (i) The width of insulation must sufficiently cover any masonry cavity closer, thus avoiding any risk of condensation through cold bridging. (ii) The side projections of the DPC must project beyond the masonry closer into the cavity, and must not be bridged by mortar. The DPC projection into the opening must locate within the frame. (iii) The vertical insulated DPC must be dressed into the cill cavity tray and be located behind the head cavity tray or sealed to the soffit of the lintel. (iv) Where it is necessary to joint the Insulated DPC vertically, the upper piece must be installed with the mm extension at the bottom with this lapping over and to the outside of the lower piece and sealed. Weepholes BS 5628: Part 3: 2001, Use of masonry, states that weepholes should be left in the outer leaf of the brickwork immediately above a cavity tray. These should be formed by leaving open perpend joints at not greater than 1 m intervals in the course of brickwork immediately above the cavity tray, with not less than two weepholes over each window/door opening. Water leaving the weephole will contain cementitious materials, which will cause staining on the masonry face. In addition an open perpend can allow the ingress of wind driven rain, snow and insects. To overcome these problems a perpend filter system should be used which will eliminate staining by a filtering action, while allowing the water to escape. Such systems are incorporated into the brickwork and reduce the visual impact of weepholes. 2 (v) Where it is necessary to give temporary support to the Ruberoid Insulated DPCs whilst building brickwork, this should be done by turning the material over onto the top of the blockwork and securing by weighting down with masonry. On no account should the DPCs be secured by nailing. Note: Ruberclose FR is self-supporting due to the rigid nature of the product. 3
34 NB CLOAK SUPPLIED IN TWO PARTS TO SUIT COLUMN WIDTH BACKFILL BACKFILL BACKFILL HYLOAD ORIGINAL OR PERMABIT DPC CAVITY TRAY MORTAR INFILL RIGID INSULATION PLASPRUFE 2000 SA SELF ADHESIVE PRIMER HYLOAD ORIGINAL OR PERMABIT DPC 50mm MIN. SAND/CEMENT SCREED PLASPRUFE 2000 SA SELF ADHESIVE PRIMER HYLOAD ORIGINAL OR PERMABIT DPC CAVITY TRAY MORTAR INFILL RIGID INSULATION GASTITE DPM SELF ADHESIVE PRIMER GASTITE DPC HYLOAD ORIGINAL OR PERMABIT DPC CAVITY TRAY MORTAR INFILL RIGID INSULATION PLASPRUFE 3 50mm MIN SAND/CEMENT SCREED GASTITE DPM BITUMEN PRIMER HYLOAD ORIGINAL OR PERMABIT DPC SELF ADHESIVE PRIMER 50mm MIN SAND/CEMENT SCREED PLASPRUFE 3 BITUMEN PRIMER PLASPRUFE 2000SA or 3 TO BE PROTECTED BY 3mm PROTECTION BOARD REINFORCING STRIPS ALL DPCs MUST BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS OF BS5628:3:2001 AND BS8000:3:2001, AS WELL AS THE RUBEROID FIXING INSTRUCTIONS AND THE RECOMMENDATIONS OF THE CURRENT AGREMENT CERTIFICATE. RUBEROID HIGH PERFORMANCE DPC 150mm ABOVE FINISHED GROUND LEVEL BEDDED BETWEEN FRESH MORTAR. RUBEROID HIGH PERFORMANCE DPC LINEAR CAVITY TRAYS FORMED IN-SITU FROM STANDARD ROLL WIDTHS FULLY BEDDING DPC IN BOTH LEAVES BETWEEN FRESH MORTAR. RUBEROID HIGH PERFORMANCE DPC LINEAR CAVITY TRAYS FORMED IN SITU FROM STANDARD ROLL WIDTHS BEDDING DPC IN OUTER LEAF BETWEEN FRESH MORTAR AND SURFACE FIXED TO FACE OF INNER LEAF BY MEANS OF RUBEROID DPC JOINTING TAPE. THE INNER LEAF TO BE PRIMED USING RUBEROID SELF ADHESIVE PRIMER. THE DETAIL IS COMPLETED BY MECHANICALLY FIXING USING RUBEROID HYLOAD DPC FIXING STRIP AND PINS FIXED AT 150mm CENTRES. ALL JOINTS IN CAVITY TRAYS AND JOINTS TO AND BETWEEN PREFORMED UNITS MUST BE LAPPED A MINIMUM OF mm AND FULLY SEALED USING RUBEROID HYLOAD DPC JOINTING SYSTEM. ALL DPCs SHOULD EXTEND THE FULL WIDTH OF EACH LEAF OF WALL AND SHOULD PROJECT 5mm BEYOND THE FINISHED EXTERNAL FACE OF THE BUILDING. THEY MUST NOT BE BRIDGED BY ANY EXTERNALLY APPLIED FINISH. WEEPHOLES MUST BE PROVIDED IMMEDIATELY ABOVE ALL CAVITY TRAYS AT 900mm CENTRES HORIZONTALLY WITH A MINIMUM OF TWO ABOVE ANY OPENING. ALL CORNERS, CHANGES IN LEVEL, STOP-ENDS AND THE LIKE, REQUIRED FOR CAVITY TRAYS SHOULD BE PRE-FORMED CLOAKS TO ALLOW SIMPLE JOINTING BY BRICKLAYERS. THESE PRE-FORMED UNITS MAY BE SUPPLIED FROM THE RUBEROID STANDARD RANGE OR MAY BE MANUFACTURED TO SUIT SPECIFIC REQUIREMENTS. CONTACT RUBEROID WATERPROOFING TECHNICAL SERVICES AT RUBEROID HEAD OFFICE FOR ANY ASSISTANCE REQUIRED. TELEPHONE HYLOAD ORIGINAL OR PERMABIT DPC CAVITY TRAY ALL CAVITIES MUST BE KEPT CLEAN OF ANY DEBRIS AND MORTAR DROPPINGS. ANY MORTAR DROPPINGS ON THE DPC MUST BE HYLOAD DPC BUILT INTO REMOVED BEFORE THEY SET, TAKING CARE NOT TO DAMAGE THE BLOCKWORK MIN 40mm DPC. ANY DAMAGE MUST BE REPAIRED IN ACCORDANCE WITH RUBEROID RECOMMENDATIONS AND TO THE SATISFACTION OF ALL PARTIES CONCERNED. HYLOAD DPC/TANKING RUBEROID HIGH PERFORMANCE DPC LINEAR CAVITY TRAYS WITH LINK LAP FORMED AFTER STOP ENDS TO BE PROVIDED TO ALL WINDOW / DOOR HEADS AND CONCRETE IS CAST. WINDOW CILLS & SHOULD EXTEND TO INCLUDE THE VERTICAL DPC. JAMBS TO DOOR AND WINDOW OPENINGS WHICH INCORPORATE RUBERCLOSE OR RUBERCLOSE FR,THE DPC PORTION MUST MORTAR INFILL PROJECT A MINIMUM 40mm INTO THE CAVITY AND PROJECT SO AS TO LOCATE TO THE DOOR AND WINDOW FRAME. ENSURE THAT THE VERTICAL DPCs LAP ONTO THE CORRECT SIDE OF HEAD AND CILL TRAYS. VERTICAL DPCs SHOULD BE IN ONE PIECE AND MUST LAP OVER THE OUTSIDE OF THE LOWER PIECE, A MINIMUM OF mm AND BE SEALED USING RUBEROID HYLOAD DPC JOINTING TAPE. WHEN USED AS A TOTAL SYSTEM RUBEROID HIGH PERFORMANCE PLASDRAIN 12 DPCS AND CAVITY TRAYS ALLOW A PRACTICAL METHOD OF COMPLYING WITH THE REQUIREMENTS OF BS5628:3:2001, BS8215:1991 AND BS8000:3:2001 PERMANENT SHUTTERING REDSTOP AND REVOFIX PLASPRUFE 3HD (LOOSE HUNG WITH SEALED LAPS) FLEECE SIDE TOWARDS CONCRETE PLASPRUFE 3 REINFORCING STRIP SYNTHAPRUFE LAC COPYRIGHT RESERVED 40mm MIN. MORTAR INFILL R.C. STRUCTURE BLOCKWORK 50mm (MIN) SAND/CEMENT SCREED HORIZONTAL PLASPRUFE 2000SA PLASPRUFE 2000SA REINFORCING STRIP (CUT FROM ROLL) INTERNAL CORNER CLOAK PIPE SLEEVE REDSTOP ALL LAPS BETWEEN UNITS AND MEMBRANES TO BE A MINIMUM OF mm & FULLY SEALED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS PIPE SLEEVE DETAIL VERTICAL PLASPRUFE 2000SA SELF ADHESIVE PRIMER A range of pre-formed units in standard shapes are available to negotiate critical changes in direction. Non standard units can be produced as required. Pre-formed units are fabricated from specially formulated sheet material which is a blend of synthetic polymers, compatible with all Ruberoid tanking membranes. CABLE TIE OR METAL SECURING CLIP TO BE APPLIED HERE. LEADING EDGE OF CLOAK TO BE SEALED WITH A BEAD OF RUBERFLEX MASTIC mm FULLY SEALED LAP PLASPRUFE 2000 SA PLASPRUFE 3HD (LOOSE LAID WITH SEALED LAPS) FLEECE SIDE TOWARDS CONCRETE 50mm SAND OR SAND/CEMENT BLINDING PIPE CLOAK EXTERNAL CORNER CLOAK PLASPRUFE 3mm PROTECTION BOARD OR PLASDRAIN 12 BACKFILL PLASPRUFE 3mm PROTECTION BOARD BACKFILL 50mm CONCRETE BLINDING 50mm CONCRETE BLINDING SELF ADHESIVE PRIMER GASTITE DPM REINFORCING STRIP PLASDRAIN 12 (OPTIONAL) BITUMEN PRIMER PLASPRUFE 3 REINFORCING STRIP GASTITE DPM SELF ADHESIVE PRIMER GASTITE DPM PLASPRUFE 3 HD BITUMEN PRIMER PLASFLOW 25 GASTITE DPM & PLASPRUFE 3mm PROTECTION PLASPRUFE 3mm BOARD PROTECTION BOARD OR PLASDRAIN 12 50mm CONCRETE BLINDING SELF ADHESIVE PRIMER PLASFLOW 25 PLASPRUFE 2000SA REINFORCING STRIP (CUT FROM ROLL) PLASPRUFE 3 HD PLASPRUFE 3 BACKFILL PROTECTION BOARD PLASPRUFE 2000SA SELF ADHESIVE PRIMER PLASPRUFE 2000SA PLASFLOW 25 PLASPRUFE 2000SA & PLASPRUFE 3mm PROTECTION BOARD COPYRIGHT RESERVED 34 HYLOAD DPC AND CAVITY TRAY SYSTEMS Technical support Technical Services For technical advice relating to all aspects of damp proofing or tanking, contact Technical Services on Technical/on-site support Ruberoid s national network of Project Managers will be pleased to help specifiers and end users with practical advice on installation procedures, calculations and any other information they may require. The service is free to specifiers and end users who can benefit from Ruberoid s unequalled experience in this highly technical field. Structural Waterproofing Design Service Ruberoid recognises that specifiers do not always have the time and in-depth information they need to become DPC and tanking specialists. For this reason the Ruberoid Structural Waterproofing Design Service is organised to provide fast, expert help on waterproofing detailing to help specifiers progress work quickly and efficiently. For assistance contact Technical Services. Again, the service is free to specifiers and end users who can benefit from Ruberoid s unsurpassed experience in this highly technical field. Ruberoid staff have specialist knowledge and experience of designing and producing 3D/isometric drawings of the complex shapes required to provide effective damp-proofing. Using state of the art technology the desired DPC shapes are factory welded to create accurately formed and totally waterproof units. Training Product training and installation sessions are offered to both UK and overseas customers at the purpose built Ruberoid Training Centre at Appley Bridge. Specification services Ruberoid subscribes to NBS Plus, which is an electronic library of technical details and guidance notes. NBS Plus is a library of manufacturers product information, linked to specific clauses within the NBS specification software products. It enables Ruberoid to make its product information available to specifiers at the point they need it most - when completing a specification. Links within the specification software allows the user to specify products quickly and accurately by simply dragging and dropping the product information directly into a specification. Ruberoid also offers RIBA-approved CPD seminars for above and below ground waterproofing. To find out more about NBS Plus specifications and these seminars please contact us on Tel: RUBEROID STANDARD PREFORMED CLOAK RANGE TYPE 1 TYPE 2 TYPE 3 TYPE 5 TYPE 6 TYPE 7 SPECIFICATION FOR THE INSTALLATION OF RUBEROID CAVITY TRAY JOINTING HIGH PERFORMANCE DPCs FOLD ENDS TO HYLOAD DPC JOINT REST ON MASONRY SUPPORT BOARD BY 25-40mm TYPE 10 RUBEROID SPECIAL PREFORMED CLOAKS CONTACT AREA PROJECT MANAGER FOR DESIGN ASSISTANCE APPLY DPC CAVITY TRAY TO ADHESIVE ON JOINT SUPPORT BOND HYLOAD DPC JOINTING TAPE TO DPC TYPE 8 TYPE 8s TYPE 9 TYPICAL WINDOW ARRANGEMENT WIND POST DETAIL SURFACE FIXING DETAIL TRADITIONAL JAMB DETAIL BUILT IN CAVITY TRAY COMPOSITE INNER SKIN DETAIL JOINT IS FULLY Angles and Corners REMOVE RELEASE SUPPORTED, These should be provided with a 330mm wide reinforcing FILM AND strip of APPLY Plasprufe DPC(cut from a roll) before LAPPED commencing AND with SEALED main membrane. CAVITY TRAY Horizontal application Whilst removing the film and unrolling the membrane, another operator should follow behind with a soft broom, working from the centre outwards, to remove any air bubbles. All laps must be minimum mm wide and lap joints should be checked as work proceeds, rolling to ensure good bonding. Protect the membrane as soon as possible with Plasprufe Protection Boards or sand/cement screed. Vertical Application Cut to required length. Starting at the top, remove about 300mm of release film and bond the membrane to the surface. Progressively remove the release film and press onto the surface, working from the centre outwards to remove all air bubbles. The upper edge of membrane must be fixed with Hyload DPC Fixing Strip and Pins, or sealed into a chase. When externally tanking, the membranes must be protected with Plasprufe Protection Boards or PlasDrain 12 prior to backfill. When internally tanking the membrane must be fully sandwiched within the wall by a 40mm minimum mortar fill against the membrane. TYPICAL ROOF ABUTMENT DETAIL PLASPRUFE 2000 SA DPM/DPC LINK GASTITE DPM/DPC Ruberoid preformed LINKcloak arrangement to suit pitched roof abutments. Dimensions as requested by site. Lead to be sourced elsewhere and to be installed in the traditional manner. PLASPRUFE 3HD REVERSE TANKING APPLEY LANE NORTH, APPLEY BRIDGE, WIGAN, WN6 9AB TEL: FAX: PROJECT: TYPICAL DPC DETAILS DATE: DRAWN BY: 22/02/05 AP DRAWING No: DPC 2005 DETAILS AT PILE CAP PLASPRUFE 3 DPM/DPC LINK RUBEROID HEAT ACTIVATED SYSTEMS All surfaces must be smooth, clean and dry. Loose material and sharp protrusions should be removed mechanically. All areas should be primed with Bitumen Primer. Allow to dry completely. The newly applied primer should be protected from contamination. Angles and Corners There should be reinforced with a 330mm wide piece of Plasprufe reinforcing strip (Plasprufe 3) equidistant across the previously primed area. When angles have been reinforced, the membrane should be applied as follows; Horizontal Application Unroll and set out the first roll as required. Each roll should be rolled back halfway, then rolled forward, fully bonding to the substrate by torch application and torch welding the side laps, which should be mm wide. Plasprufe 3 should be protected as soon as possible by Plasprufe Protection Boards or a sand/cement screed to prevent damage. Plasprufe 3HD, being self protected by a heavy duty polyester mat, does not require additional protection in normal application. Vertical Application Cut the membrane to an appropriate length. Starting at the bottom, torch weld the membrane to the vertical section of the reinforcing strip, allowing a minimum of mm lap between the two sheets. Then working upward, torch apply the material to the previously primed surface. Repeat the procedure, allowing minimum mm overlaps which should be torch welded. Where more than one sheet is required to cover a vertical drop, the upper sheets should always overlap the lower sheets with a bonded lap of at least mm. Where the vertical sheets terminate, the uppermost end should be mechanically fixed with Hyload DPC Fixing Strip and Pins or turned into a chase and sealed. These drawings are indicative only and by no means comprehensive. All products to be installed in accordance with standard published installation instructions. SCALE: NTS REVISION: B INTERNAL TANKING DETAIL RUBEROID PRE-FORMED UNITS (CLOAKS) PLASPRUFE 3 HD REVERSE TANKING TECHNIQUE Reverse tanking is a tanking technique whereby the tanking membrane is applied to the internal face of the permanent shuttering prior to having the substructure constructed within the waterproofed enclosure. The benefits of this technique are to maximize the footprint of the construction, enabling the structure to be as close as possible to the party boundary. It provides simplified sequencing that results in savings in the construction costs and time compared with traditional external tanking. Install the horizontal Plasprufe 3HD as per the guidelines on the data sheet. Where the horizontal/vertical junction occurs, lay out a roll of 330mm Plasprufe 3 reinforcing strip at right angles - half on the horizontal, half on the vertical. Form a torch bonded lap between the main horizontal Plasprufe 3HD membrane and the horizontal section of the reinforcing strip. Place the first section of 3HD into position vertically, with the protective fleece facing 'inward' (this part of the operation may require two persons). It will be necessary to temporarily secure the uppermost edge of the 3HD. Extend the 3HD above the level of the retaining wall. Heat bond the lower edge of the 3HD over the vertical section of the reinforcing strip. Place the next vertical strip of 3HD into position and repeat but also heat bond it to the exposed edge of the previous strip. Ensure that the bond is fully secure. Repeat this sequence along the required distance, before casting the main slab area, up to kicker level. Place the Ruberoid Redstop in the centre of the kicker and at day joints and mechanically secure it in place with Revofix Securing Mesh. Cast the remaining concrete in place, ensuring the vertical 3HD is temporarily secured, to prevent sagging. Once the concrete has set, cut and fold the 3HD over the top edge of the concrete, trimming as necessary. Secure Hyload Original or Permabit DPC to it by gently heat activating the bitumen on the 3HD, and sticking the DPC firmly in position. The remainder of the DPC cavity tray can be installed in the traditional way. Note: The above guidelines should be read in conjunction with the material data sheets. GASTITE EXTERNAL TANKING SYSTEM PLASPRUFE 3 HD EXTERNAL TANKING SYSTEM RUBEROID PRIMERS SELF ADHESIVE PRIMER A BLACK, MODIFIED BITUMEN SOLUTION FOR USE AS A PRIMER FOR ALL SELF ADHESIVE MEMBRANES DRYING TIME 1 HOUR AT 18 c COVERAGE 4m²-6m²/LITRE SIZES 5 and 25 LITRE RUBEROID BITUMEN PRIMER A BLACK BITUMEN SOLUTION FOR USE AS A PRIMER FOR ALL TORCH APPLIED MEMBRANE SYSTEMS. DRYING TIME 5 HOURS AT 18 c COVERAGE 4m²-6m²/LITRE SIZES 5, 25 and 200 LITRE DRYING GUIDES ALL PRIMED SURFACES ARE TO BE DRY SHINY AND BLACK PRIOR TO TANKING APPLICATION. MATT AND BROWN SURFACES REQUIRE MORE PRIMER AND FURTHER DRYING TIME PROJECT: PLASPRUFE 2000SA EXTERNAL TANKING SYSTEM APPLEY LANE NORTH, APPLEY BRIDGE WIGAN. WN6 9AB TEL: FAX: TYPICAL TANKING DETAILS DATE: DRAWN BY: SCALE: 22/02/05 AP NTS DRAWING No: REVISION: TANK 2005 B The Pulse designer flats, London Architect: Koski Soloman & Ruthven
35 HYLOAD DPC AND CAVITY TRAY SYSTEMS 35 Supply & references Availability Ruberoid High Performance DPCs are available through a network of distributors/merchants nationwide. Orders should state the types of quantities required, delivery date and site address. Stock items are normally delivered within 3 working days. Delivery of special units is normally within 7-10 working days from confirmation of order. Details of the Ruberoid Customer Services offices is shown overleaf. Standard Preformed Cloaks Units Normally available from stock. Orders and enquiries should be addressed to your nearest sales office. Orders should state the codes and quantities of each type of unit, delivery address and date required. Special (project specific) Preformed Cloak Units Enquiries should be addressed to the Structural Waterproofing Design Service at Appley Bridge, enclosing relevant plan, elevation and sectional drawings. This information should be provided as early as possible to ensure that delivery can be met. Health and safety Separate health and safety data sheets are available on request. Other products Ruberoid manufacture and supply a wide range of other waterproofing products for tanking and bridge decking requirements, as well as roofing products, solutions and compounds. Full product literature is available on request. Prices, Conditions of Sale Current prices and price lists are available from our sales offices. Our standard Conditions of Sale are included in our price list and all sales of Ruberoid products are made under these conditions. Ruberoid Business Managers can also provide prices and conditions of sale on request and will be happy to discuss your requirements in more detail. Standards referred to in this publication BS 743: 1970, Specification for materials for damp proof courses BS 5628, Code of practice for use of masonry Part 1: 1992, Structural use of unreinforced masonry Part 3: 2001 Materials and components, design and workmanship BS 6398: 1983, Specification for bitumen damp proof courses for masonry BS 8000, Workmanship on building sites Part 3: 2001, Code of Practice for masonry Part 4: 1989, Code of Practice for waterproofing BS 8102: 1990, Code of practice for protection of structures against water from the ground BS 8215: 1991, Code of Practice for design and installation of damp proof courses in masonry construction BS 8300: 2001, Code of Practice for design of buildings and their approaches to meet the needs of disabled people CP 102: 1973, Code of Practice for protection of buildings against water from the ground (damp-proofing of floors) BRE Digest 77, Damp proof courses BRE Digest 380, Damp proof courses
36 Ruberoid Building Products Customer Services Appley Lane North, Appley Bridge, Wigan, Lancashire WN6 9AB Tel: Fax: Front cover image is the Tulip Inn, Trafford Park completed by Marlborough Brickwork using Hyload Structural Waterproofing throughout. Whilst every care is taken to see that the information given in this literature is correct and up to date it is not intended to form part of any contract or give any collateral liability, which is hereby specifically included. Intended purchasers of our materials should therefore verify with the company whether any changes in our specification or application details or otherwise have taken place since this literature was issued.
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
08 Visqueen Zedex cpt Dpc 12 Visqueen Zedex High bond Dpc 14 Visqueen preformed unit
08 Visqueen Zedex CPT DPC 12 Visqueen Zedex High Bond DPC 14 Visqueen Preformed Unit 16 Visqueen Zedex Housing Grade DPC 18 Visqueen Polyethylene DPC 20 Visqueen GX Hydrocarbon DPC 21 Visqueen Gas Resistant
BBA BRITISH. tanking. Application. Storage & Handling
58 Visqueen Self Adhesive Damp Proof Membrane 60 Visqueen Gas Resistant Self Adhesive Damp Proof Membrane 62 Visqueen Torchon Tanking Membrane 64 Visqueen GX Pre Applied Membrane 66 Visqueen Protect&Drain
Gas Membrane and Waterproof Tanking Systems
Gas Membrane and Waterproof Tanking Systems Improving Choice, Quality & Service Why Choose Miers? About Miers Miers Construction Products is an independent supplier of construction products delivering
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
CHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November 2013. l Water and water vapour barrier. l Factory controlled thickness
CI/SfB TN6 L6813 November 2013 RIW SHEETSEAL 226 is a cold applied, high density polyethylene film, coated with a bitumen/rubber self adhesive layer with a removable reinforced silicone paper. Primer is
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES
Sika Limited Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394 444 Fax: 01707 329 129 e-mail: [email protected] website: www.sika.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
Energy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
Including. Rubershield-Pro. Breather Membrane
Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against
The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.
Cl/SfB (13.1) Ly (L2) BRE CERTIFICATION LTD CERTIFICATE OF ASSESSMENT PRODUCT Powerbase RB 340 and RB 370 Radon Resistant Membranes CERTICATE NO. 100/03 ISSUED: MARCH 03 REISSUED: NOVEMBER 07 SUPPLIED
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
Fosroc Proofex Engage
Technical Data Sheet Pre-applied waterproofing membrane conforming to the requirements of BS EN 13967:2004 and BS 8102:2009. Proofex Engage mechanically bonds to poured concrete, remaining in place if
Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 5 Tunnels & Arches V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V Create dry usable space with the original X pattern
Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1
Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.
Glidevale offers a complete range
CI/SfB (13.9) Uniclass Ss_32_20_30_48 June 2016 Glidevale offers a complete range of protection for ground floors against both damp and gases from the ground. This double function avoids the need for a
Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY
CI/SfB Oct 12 (47) Ln Uniclass L524 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY Bailey Flame-free felt roofing Bailey
DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP
DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6
Ubiflex. Non-lead flashing system
Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
Introduction & Principles Issued in support of Junction Details, Parts 1 to 5
Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction
Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
GAS PROTECTION SYSTEMS
GAS PROTECTION SYSTEMS Solco Building Products provide the complete gas protection system for the protection of buildings on contaminated land. Bluebay Building Products are the exclusive distributor of
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
Rockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
WATERPROOFING SikaProof -A TECHNOLOGY
SikaProof -A TECHNOLOGY content What is SikaProof -A? 6 How does it work? 8 Where can it be used? 0 What are the advantages of SikaProof -A? 2 How should it be installed? SikaProof -A system components
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
OLDROYD. Interior Walls. Interior Walls. below and above ground. below and above ground
S S.doc.2 12/3/03 6:26 pm Page 1 Oldroyd produce a wide range of products to combat the problems of water ingress and dampness in buildings. Other brochures are available covering the following : We have
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
WATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
Roofers Guide to Underslating Membranes
Roofers Guide to Underslating Membranes IKO is a worldwide enterprise, with more than 3000 employees, and manufacturing plants in Canada, the United States, United Kingdom, Belgium, Holland, France and
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
DENSO WATERPROOFING SYSTEMS
DENSO WATERPROOFING SYSTEMS Approved Quality Management System AS/NZS ISO 9001:2008 Lloyds Register Certificate N o Mel 0927759 Denso (Australia) Pty Ltd A MEMBER OF WINN & COALES INTERNATIONAL 411 413
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
0331 Brick and block construction
0331 BRICK AND BLOCK CONSTRUCTION This worksection has been written for Class 1 and 10a buildings that fully conform to the scope of AS 4773.1. If the works include isolated structures, (totally separate
WATERPROOFING FOR CONCRETE STRUCTURES
MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck
Site Inspection Report
Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G
The formation of roof waterproofing details calls for
3.5 BUILT-UP ROOFING DETAIL DESIGN INTRODUCTION The formation of roof details calls for a combination of the skills of the designer and the roofer. There are many different approaches to detail design
Monarflex Tanking & DPM Systems. Cold and Hot. Applied. Structural. Waterproofing. Membranes YEAR. Geomembr nes WORLD LEADER IN WATERPROOFING
Monarflex Tanking & DPM Systems CI/SfB 27.2 May 2005 N6 Cold and Hot Applied Structural Waterproofing Membranes 20 YEAR STRUCTUAL WATERPROOFING GUARANTEE Exclusively Supplied and Installed by WORLD LEADER
Concrete Waterproofing Systems. Integral Protection. www.tritonsystems.co.uk
Concrete Waterproofing Systems Integral Protection n Type B Integral Protection in accordance with BS 8102 (2009) n Unique chemical admix for waterproofing and protection of concrete n A complete and permanent
PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET
CI/SfB (49) Mh8 Midland Lead Manufacturers Ltd Kiln Way Woodville Swadlincote Derbyshire DE11 8ED Tel: 01283 224555 Fax: 01283 550284 e-mail: [email protected] website: www.midlandlead.co.uk Agrément
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with
Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and
Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate
CAD details Triflex ProDetail Triflex system: Triflex ProDetail Solution type: Roof detail and repair waterproofing Application: Overlay of existing substrate CAD details CAD S: CAD details Triflex ProDetail
House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors
W42_Stand_Extra_32 15/3/05 9:17 am Page 2 NHBC s technical newsletter April 2005 Issue 32 This edition includes: 2 House building is changing fast NHBC unveils new Standards Chapters on curtain walling
Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining
Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02
NRG 75 CRF NRG GREENBOARD WALL SYSTEM
NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark
ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE
Alumasc Exterior Building Products Ltd White House Works Bold Road Sutton St Helens Merseyside WA9 4JG Tel: 01744 648 400 e-mail: [email protected] website: www.alumascroofing.co.uk APPROVAL
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Dubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
FIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
The Kingspan Insulation Price List 1 st January 2013
Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings
Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)
THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types
Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form
Construction Product Data Sheet Edition 15/07/2013 Identification no: 01 07 05 04 001 0 000001 Sika 1 Pre-Bagged Structural Waterproofing System Product Description Pre-Bagged Structural Waterproofing
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Manual lifting and handling
Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details
The WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.
STEP-BY-STEP construction guide Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. Welcome to our CONSERVATORY AND SUNROOM CONSTRUCTION GUIDE What is the specification
ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE
Mapeguard WP System ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE Products used: Mapeguard WP 200, Mapeguard ST, Mapeguard IC, Mapeguard EC, Mapeguard WP
CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com
CI/SfB (31.9) Hh2 BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE www.iglintels.com BETTER BY DESIGN IG produce the UK s largest range of steel lintels backed by industry leading
SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)
(Fixed Lite Window Illustrated) SINGLE LEAF CLADDING / CORRUGATED STEEL (Awning Window Illustrated) SINGLE LEAF CLADDING / FOAM BOARD (Casement Window Illustrated) BRICK VENEER CONSTRUCTION (Horizontal
Module 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
Chapter 2 Basis of design and materials
Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural
CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd
CI SfB (4-) Nn2 Onduline Mini Profile Onduline Garden Roof Range Onduline Building Products Ltd Onduline Garden Roof Range Onduline Mini Profile The new Onduline Mini Profile sheets have been designed
Steel-framed Walls. Insulation
Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable
The Guide To Waterproofing An Existing Basement
The Guide To Waterproofing An Existing Basement John Newton & Company is the leading independent supplier of basement waterproofing and damp proofing solutions in the UK. Newton System 500 is a maintainable
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.
Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them
www.pitchmasticpmb.com PmB Expansion Joints World leaders in expansion joint technology
www.pitchmasticpmb.com Expansion Joints World leaders in expansion joint technology High performance expansion joint solutions Pitchmastic offers a comprehensive range of specialist services to the civil
KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION
Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: [email protected] APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
I-Line - Snap-On Feature
Oct 2012 I-Line - Snap-On Feature DATA SHEET Snap-On features - Guaranteed truelines every time Bailey I-Line Snap-On is an architectural cladding feature offering creative possibilities for architects
EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5
Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS
MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS May 29, 2013 Revision B Structural Guideline for Design and Installation Holes in Composite Floor Slab Terminal 3, Departure Level
AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com
AND MEMBRANES 010 ROOFING UNDERLAYS 1 HO DOES YOUR ROOF BREATHe? MEMBRANES THE WAY to A WARM AND DRY ROOF HO HO HO HO HO HO WATERTIGHTNESS The FAKRO Company offers a wide range of membranes and underlays
How To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking
Monocouche Best Practice Guide New-Build Housing Managing movement to avoid cracking Avoiding Cracking For The Designer Visible cracks in render are unsightly and although not hazardous to the construction
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
The BASA Guide to the ISO 11600 Classification of Sealants for Building Construction
The BASA Guide to the ISO 11600 Classification of Sealants for Building Construction SEALANTS IN BUILDING AND CONSTRUCTION Glazing Sealants (G) Construction Sealants (F) Class 25 Class 25LM Class 25 Class
ICOPAL POUR AND ROLL ROOF WATERPROOFING ICOPAL POWER ELASTOMERIC ROOF WATERPROOFING SYSTEM
Icopal Limited Barton Dock Road Stretford Manchester M32 0YL Tel: 0161-865 4444 Fax: 0161-864 8433 e-mail: [email protected] website: www.icopal.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL
Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
RHEPANOL RHEPANOL FK ROOF COVERING SYSTEM
Flachdach Technologie GmbH & Co KG Eisenbahnstrasse 6 8 68199 Mannheim Germany Tel: 00 49 621 8504-372 Fax: 00 49 621 8504-378 e-mail: [email protected] website: www.fdt.de APPROVAL INSPECTION TESTING CERTIFICATION
