Determining Air Barrier Performance
|
|
|
- Arthur Goodman
- 9 years ago
- Views:
Transcription
1 solutions for the construction industry december 2009 Determining Air Barrier Performance The Offi cial Magazine of the q Construction Specifi cations Institute also in this issue Using CPVC for Industrial Piping Seismic Tests for Brick Assemblies Linking with Keynotes
2 Testing Mechanically Fastened Air Barrier Systems Under Wind Pressure by maria Spinu, phd, CSi, leed ap, and alan learned, phd All photos courtesy DuPont ABOUT 40 PERCENT OF THE WORLD S ENERGY IS CONSUMED BY THE BUILDING SECTOR, AND ABOUT 37 PERCENT OF THIS IS FOR HEATING, COOLING, AND VENTILATION. 1 SINCE AIR LEAKAGE HAS A SIGNIFICANT EFFECT ON HVAC USE, DESIGN PROFESSIONALS MUST UNDERSTAND HOW A CONTINUOUS AIR BARRIER SYSTEM CONTRIBUTES TO AN ENERGY-EFFICIENT ENVELOPE. Air infiltration is a property that is inherent to each material and can be measured in the lab, but whole building air leakage is highly dependent on field installation and quality of workmanship. Testing of air barrier assemblies is an important intermediate step for developing proper installation guidelines and best practices. The standard method for testing of air barrier assemblies is ASTM E (2000), Standard Specification for an Air Barrier Material or System for Low-rise Framed Building Walls. A more recent standard for determining air leakage of air barrier assemblies in commercial enclosures ASTM E , Standard Test Method for Determining Air Leakage of Air Barrier Assemblies requires testing under significantly more stringent conditions. This article reviews test methods and performance requirements for air barriers, with special focus on assemblies constructed with mechanically fastened membranes (i.e. building wraps). ASTM E 2357 testing of assemblies constructed with commercial-grade spun bonded polyolefin (SBP) membranes shows these systems outperform requirements for air barrier assemblies, when installed per the manufacturer s instructions. This allows a tighter and more energy-efficient building envelope. Air infiltration and air leakage This section gives a brief summary of the test methods and requirements for air barrier materials, assemblies, and whole buildings. 2 Air barrier materials Air barrier materials are defined by their level of air permeance, which is the amount of air that migrates through a material. The standard test method for determining air infiltration in this context is ASTM E 2178, Standard Test Method for Air Permeance of Building Materials. Performance requirements for air barrier materials have been specified in the National Building Code of Canada (NBC) since NBC requires air barriers have an air permeance not to exceed 0.02 L/s m 75 Pa (0.004 cfm/sf under a pressure differential of 0.3 in. H 2 O [1.57 psf]). In 2001, Massachusetts became the first state to adopt an air barrier code in the United States with similar requirements as NBC. Other states (Georgia, Minnesota, Rhode Island, Washington, and Wisconsin) and agencies (e.g. U.S. Army Corp of Engineers [USACE] and General Services Administration [GSA]) are beginning to mandate air barriers and enforce airtightness standards. Few other states are developing such codes. A national standard for air barriers is needed. American Society of Heating, Refrigerating, and Air-conditioning Engineers
3 (ASHRAE) 90.1, Energy Standard for Buildings Except Low-rise Residential Buildings, has been developing an air barrier standard for the past four years. The last public review of the ASHRAE 90.1 air barrier proposal was published June 19, Many common building materials meet the air permeance requirement. A few examples are: plywood minimum 10 mm ( 3 8 in.); oriented strandboard (OSB) minimum 10 mm; extruded polystyrene (XPS) insulation board minimum 19 mm ( 3 4 in.); foil-faced urethane insulation board minimum 12 mm ( 1 2 in.); exterior gypsum sheathing or interior gypsum board minimum 12 mm; cement board minimum 12 mm; built-up roofing (BUR) membrane; modified bituminous (mod-bit) roof membrane; fully adhered single-ply roof membrane; a portland cement/sand parge, stucco, or gypsum plaster minimum 16 mm ( 5 8 in.) thick; cast-in-place (CIP) and precast concrete; and sheet metal. Materials specifically designed as air barriers include premanufactured sheet structures (i.e. mechanically fastened or self-adhered membranes) or fluid-applied membranes and foams. Some weather-resistive barriers (WRBs) also meet the material requirements for air barriers, however many others (including building paper and perforated wraps) do not. Air barrier assemblies Air barrier assemblies are made up of primary air barrier materials and accessories (e.g. primers, sealants, tapes, flashing, mechanical fasteners, etc.) that provide a well-designed air barrier systems can improve a building s energy efficiency, but proper field installation is crucial. continuous designated plane to the movement of air through portions of building enclosure assemblies. The air leakage rate for assemblies is the sum of air infiltration through both materials and the unintended holes or gaps at penetrations and transitions. As mentioned, ASTM E 1677 and ASTM E 2357 are the two accepted standards for testing air barrier assemblies under conditions simulating actual use. ASTM E 1677 describes the testing method and includes performance criteria for air leakage rate of air barrier assemblies not to exceed 0.3 L/s m 75 Pa (0.06 cfm/sf at 0.3 in. H 2 O [1.57 psf]) when tested in accordance with ASTM E 283, Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. ASTM E 2357 requires significantly more stringent test conditions, but does not specify an air leakage rate for air barrier assemblies. Instead, the air permeance values at 75 Pa for the exfiltration and infiltration conditions Figure 1 Summary CompariSon Between astm e 1677 and astm e 2357 ASTM E ASTM Number of test specimens and configuration Conditions for air leakage testing Pressure-loading schedule One specimen: Opaque Wall (8 x 8-ft walls) Single test pressure: 75 Pa (1.56 psf); 40 km/h (25 mph) (Positive pressure) Sustained loads up to +500 Pa (10.4 psf); km/h (65 mph) (Positive pressure) Test two of the three specimens (8 x 8-ft walls): 1 Opaque wall 2 Wall with penetrations 3 Wall-foundation interface Seven test pressures: +/ 25 Pa (0.56 psf); 24 km/h (15 mph) +/ 50 Pa (1.04 psf); 32 km/h (20 mph) +/ 75 Pa (1.56 psf); 40 km/h (25 mph) +/ 100 Pa (2.09 psf); 46 km/h (28.8 mph) +/ 150 Pa (3.24 psf); 56 km/h (35 mph) +/ 250 Pa (5.23 psf); 73 km/h (45.6 mph) +/ 300 Pa (6.24 psf); 80.5 km/h (50 mph) (Positive & negative pressures) Sustained: +/- 600 Pa (12.5 psf); 113 km/h (71 mph) Cyclic: +/- 800 Pa (16.7 psf); 130 km/h (81 mph) Gust: +/ Pa (25 psf); 161 km/h (100 mph) (Positive & negative pressures)
4 Figure 2 are used to establish the system air leakage rating. ASHRAE 90.1 s air barrier proposal specifies performance criteria for average air leakage rate of air barrier assemblies in other words, not to exceed 0.2 L/s m 75 Pa (0.04 cfm/sf under a pressure differential of 0.3 in. H 2 O [1.57 psf]) when tested in accordance with ASTM E 1677 or ASTM E The International Building Code (IBC) requires a continuous weather-resistive barrier to protect against water intrusion. However, for a WRB to also perform as an air barrier, it must: meet the material permeance criteria (e.g. not to exceed 0.02 L/s m 75 Pa (0.004 cfm/sf under a pressure differential of 0.3 in. H 2 O [1.57 psf]); and be installed in such a manner as to meet air leakage requirements for air barrier assemblies (e.g. not to exceed 0.3 L/s m 75 Pa (0.06 cfm/sf at 0.3 in. H 2 O [1.57 psf]). 3 Whole building air leakage The standard test method for whole building air leakage is ASTM E , Standard Test Method for Determining Air Leakage Rate by Fan Pressurization (e.g. the blower door test). Currently there are no criteria for air leakage rate of whole buildings. For example, ASHRAE 90.1 requires sealing, caulking, gasketing, or weatherstripping at joints and interfaces, but does not specify an air leakage rate. The ASHRAE 90.1 air barrier proposal includes criteria for air leakage rate of air barrier materials and assemblies, but not for whole buildings. The only guideline for whole building air leakage rate is provided by the U.S. Army Corps of Engineers, which requires blower door testing of all new buildings and an average air leakage rate not to exceed 1.25 L/s m 75 Pa (0.25 cfm/sf at a pressure differential of 0.3 in. H 2 O [1.57 psf]), when tested in accordance with ASTM E or an equivalent approved method. The USACE-proposed whole building air leakage rate was based on values from field testing available to date, 4 and are achievable with current technologies using best practices. the configuration of the three wall assemblies for astm e 2357 testing. Testing of commercial air barrier assemblies The ultimate goal when using an air barrier is to reduce air leakage both in (i.e. infiltration) and out (i.e. exfiltration) of the building, and to achieve a tight envelope. Testing of air barrier materials, while important, is not enough to ensure whole building performance because actual installation methods are critical. On the other hand, while whole building testing can be done, it might be too late to find out the project leaks after it has been completed. Testing of air barrier assemblies is a very important intermediate step for establishing the best installation methods for a system that performs under use conditions. Figure 1 provides a summary comparison between the two test methods currently accepted for air barrier assemblies. As mentioned, this article focuses on the more stringent ASTM E , which is a laboratory procedure, but may also be applied to site mockups. It requires up to three specimens, each additionally representing different
5 field conditions. Figure 2 shows the configurations of the three test assemblies. Measurements must be performed on two of the three test specimen. (Specimen 3 is optional and may be combined with Specimen 2.) ASTM E 2357 requires at least seven measurements of air leakage rate under both positive and negative pressures (i.e. infiltration/exfiltration) at each of the air pressure differences across the test specimen indicated in Figure 1. Pressure loading schedule After the initial air leakage testing, ASTM E 2357 requires each specimen be exposed to a structural loading schedule (i.e. conditioning). The wall assembly s structural loading is based on the assumption the air barrier: takes the full wind loads (i.e. pressure-equalized façade systems); experiences repeated cycling of high positive and negative pressure loads during its service life (i.e. thousand cycles); and experiences two severe storms in the first 15 years in service. Figure 3 shows the pressure load profiles for sustained loads, cyclic loads, and gust loads at pressures indicated in Figure 1. Figure 3 astm e 2357 wind loading schedule for sustained, cyclic, and gust loads. Figure 4 opaque wall assemblies constructed with spun bonded polyolefin (SBp), using screws/washers or brick ties as fasteners. Post-conditioning air permeance The air leakage test is repeated after the pressure loading, and the post-conditioning air leakage rates at 75 Pa are used to establish the assembly air leakage rating. Deflection measurements ASTM E 2357 requires the maximum deflections of the air barrier material and test specimen be measured following the pressure load testing. These deflection measurements must be recorded at wind pressures equal to the wind design values for the geographical areas (i.e. up to 1440 Pa [30 psf] or equivalent wind speed of 175 km/h [109 mph]). 5 Testing of wall assemblies with mechanically fastened air barriers Based on the application method, air barrier materials are classified as fluid-applied, self-adhered, or mechanically fastened membranes (i.e. building wraps). Installation details are specific to each type of air barrier and vary among manufacturers. Improper installation could lead to failure of any type of air barrier system. However, for building wraps, the failure caused by improper installation could be more visible, fostering a misconception building wraps do not perform as air barriers. Not all building wraps meet ASTM E 2357 performance criteria. Each manufacturer must specify all materials and components as well as how to deal with penetrations and transitions to achieve a continuous air barrier assembly. Issues such as compatibility and durability must also be addressed by the manufacturer (rather than the design professional using a trial and error method). Due to the many factors affecting performance in use, testing must be done for the specific air barrier assembly, rather than generally. Typical wall assemblies using commercial-grade SBP This article describes testing by an independent third-party laboratory of air barrier assemblies constructed with commercial-grade spun bonded polyolefins. More than two dozen wall assemblies (opaque and penetrated walls) representative of target commercial installations were built and tested to gauge their performance against the ASTM E 2357 requirements for air barrier assemblies and establish the best installation practices. Opaque wall assemblies (Specimen 1) Typical commercial walls were constructed with 2x6 18- gage steel studs (406 mm [16 in.] on center [oc]) and sheathed with exterior gypsum board. Commercialgrade SBP membranes were installed with the recommended horizontal and vertical seams, which were sealed with 76-mm (3-in.) tape, fastened into the steel studs with screws and or 51-mm (1 ¼ or 2-in.) gasketed metal or plastic washers spaced 305 or 457 mm (12 or 18 in.) oc. Brick ties with flashing patches, spaced 305 or 406 mm (16 in.) oc, were also tested as the permanent fasteners. Figure 4 shows representative pictures of the opaque wall assemblies constructed and tested by an independent third-party laboratory.
6 The air infiltration rate measured for both specimens was less than 0.05 L/s m 2 (0.01 cfm/sf) at all test pressures, under both positive and negative pressure differential. Both specimens significantly outperformed the ASHRAE 90.1 and ASTM E 1677 requirements. astm testing of air barrier assemblies is an important step for developing proper installation guidelines and best practices. Wall assemblies with penetrations (Specimen 2) The penetrated walls were the same construction as Specimen 1, but included standard penetrations as required in ASTM E 2357: window, junction boxes, duct, and pipe. The steel octagonal box and 102-mm (4-in.) polyvinyl chloride (PVC) electrical box were reinforced with tape and sealed with a commercialgrade sealant around the perimeter. The 38-mm (1.5-in.) PVC pipe was sealed using flexible flashing around the perimeter. Flexible flashing was installed at the head and sill of the window, and straight flashing was installed at both jambs. The entire window perimeter was sealed with a commercial-grade sealant. Figure 5 shows pictures of typical Specimen 2 wall assemblies, built and tested by an independent third-party laboratory. Air leakage test The initial air leakage rate was measured under the following sustained wind conditions, under both positive and negative pressure differential: + / 25 Pa (0.56 psf) or equivalent wind speed of 24 km/h (15 mph); + / 50 Pa (1.04 psf) or 32 km/h (20 mph); + / 75 Pa (1.56 psf) or 40 km/h (25 mph); + / 100 Pa (2.09 psf) or 46 km/h (28.8 mph); + / 150 Pa (3.24 psf) or 56 km/h (35 mph); + / 250 Pa (5.23 psf) or 73 km/h (45.6 mph); and + / 300 Pa (6.24 psf) or 80.5 km/h (50 mph). Figure 5 penetrated wall assemblies constructed with SBp, using screws/washers or brick ties as fasteners. also, flashing of penetrations. Pressure loading schedule After the initial air leakage testing, each specimen was exposed to a structural loading schedule (conditioning), which included: sustained loads for 60 minutes under positive and negative deformation: +/ 600 Pa (12.5 psf), or equivalent wind speed of km/h (70 mph); cyclic loading for 1000 cycles under positive and negative pressure: +/ 800 Pa (16.7 psf), or 130 km/h (81 mph); and gust loads for a three-second load under positive and negative pressure: +/ 1200 Pa (25 psf), or about 161 km/h (100 mph). After each loading stage, the wall assemblies were inspected for signs of fracture, delamination, loosening of fasteners, or other damage per ASTM E 2357 requirements. Neither specimen showed any damage under the above structural load conditions. Post-conditioning air permeance Following the structural loading test, the wall specimens were subjected to the same pressure conditions as the original air leakage testing; the infiltration rate was measured again under sustained wind conditions, positive and negative pressures. The air leakage rate for the two specimens was less than 0.05 L/s m 2 (0.01 cfm/sf) at all seven test pressures and under both positive and negative pressures. The post-conditioning air leakage rate at 75 Pa gives the air leakage rating for this assembly of less than 0.05 L/s m 75 Pa ( in. H 2 O [1.57 psf]). Both specimens significantly outperformed the requirement for air barrier assemblies per ASHRAE 90.1 that is, less than 0.2 L/s m 75 Pa ( in. H 2 O [1.57 psf]). They also outperformed ASTM E 1677, which is less than 0.3 L/s m 75 Pa ( in. H 2 O [1.57 psf]). Deflection measurements The specimens were then subjected to positive and negative deflection loads of +/ 1440 Pa (30.1 psf) or equivalent wind speed of about 176 km/h (109.3 mph). The total deflection measured under negative load was less than 25 mm (1 in.). Further, under these extreme pressure loads, the entire test assembly (including structural framing) had a deflection of more than 38 mm (1.5 in.), once again indicating the extreme structural load conditions required by ASTM E Typical structural design for commercial buildings would require additional bracing or narrower stud spacing to limit the wall deflection on the structure. Testing beyond ASTM E 2357 While ASTM E 2357 uses a very rigorous set of conditions for testing of air barrier assemblies, the high-
7 performance capability of properly installed SBP mechanically fastened wrap systems can be seen in testing beyond these parameters. After completing the ASTM E 2357 deflection test, wall assemblies were subjected to an additional air leakage test. Once again, the air infiltration measured for both specimens was less than 0.05 L/s m 75 Pa ( in. H 2 O [1.57 psf]) at all seven test pressures under both positive and negative pressure differential; this means both specimens significantly outperformed the requirement for air barrier assemblies per ASHRAE 90.1 and ASTM E The wall assemblies were then placed in a chamber and exposed to thermal cycling, consisting of 28 cycles between 17 and 82 C (0 and 180 F). The severe range in temperature tests the system s ability to not only handle the extreme temperatures themselves, but also the expansion and contraction forces created around critical interfaces in the assembly throughout the cycle. The robustness of the penetration details and taped seams in particular are stressed during this test. For the wall assembly specimens designed for the highest structural load conditions, pressure loads of up to 4310 Pa (90 psf) or equivalent wind speed of 306 km/h (190 mph) were used to further challenge the assemblies. Air penetration resistance testing (i.e. ASTM E 283) and water penetration resistance testing (i.e. ASTM E 331) was conducted after these severe thermal cycling conditions. The water test consisted of a 15-minute cycle at each of the following pressure differential: 25, 75, and 700 Pa (0.52, 1.56, and psf) or equivalent wind speeds of 23, 40, and 122 km/h (14.4, 25, and 76 mph). The best wall assemblies (employed to develop highperformance installation guidelines) showed no water leakage at the above test pressures and air leakage levels better than the proposed ASHRAE 90.1 limits. In practical terms, this testing demonstrates when the continuous air barrier is designed with recommended system components and installed per manufacturer s instructions, these systems resist the wind pressures and water penetration under expected building movement for the region in which the building is constructed. also pictured on the cover, the Children s Hospital (pittsburgh, pennsylvania) relies on an air barrier system to reduce both its unintended air leakage and its use of mechanical systems for heating and cooling. Figure 6 SCrew FaStenerS and 16 Steel Stud SpaCing Washer size Fastener spacing Allowable pressure 2 metal 2 plastic 1.25 metal psf 188 mph psf 153 mph psf 165 mph psf 133 mph psf 153 mph psf 125 mph * Values presented are maximum allowable pressures. A factor of safety may need to be applied for certain cladding systems. Mechanically fastened wrap installation keys The key to achieving this kind of high performance air barrier and water-resistive barrier system with mechanically fastened wraps is to pay particular attention to the COF installation principles continuity, overlap, and fasteners. Continuity This principle encompasses sealing seams with a durable tape, proper terminations at roof-wall interfaces, wall-to-foundation interfaces, and appropriate details for all penetrations. Overlap This refers to the proper shingling of the materials (air barrier and flashing) to facilitate efficient drainage down the system. Fasteners Fasteners are important both for durability and from an air barrier integrity perspective. Certain types of fasteners, for example slap staples, used in building paper installation methods are very poor choices for a high-performance wrap air barrier system. Cap fasteners of the appropriate design and installed at the appropriate spacing provide excellent performance. Fastener examples and their representative performance limits with wrap systems are shown in Figure 6. Summary Air leakage is one of the factors significantly affecting HVAC energy use. When properly installed, a continuous air barrier system can minimize air leakage into or out of the building. As shown by the research discussed in this article, air infiltration rates measured for air barrier assemblies constructed with commercial-grade spun bonded polyolefin, and tested under severe conditions of ASTM E 2357 standard, can significantly outperform the requirements for air barrier assemblies under ASHRAE 90.1 and ASTM E This work is instrumental in providing valuable information for optimizing the installation methods used for the development of installation guidelines for SBP air barrier systems. cs
8 Notes 1 For more on these statistics, see the May 2009 World Business Council for Sustainable Development (WBCSD) document, Energy Efficiency in Buildings Report. Visit See also the 2008 U.S. Department of Energy (DOE) Buildings Energy Databook at buildingsdatabook.eren.doe.gov. 2 More information on test methods and performance requirements of air barrier materials and assemblies can be found at the Air Barrier Association of America Web site ( 3 For further discussion on role of air and weather-resistive barriers, see the October 2009 Insight Vocabulary by Joseph W. Lstiburek online at At that site, John Straube also provides further information on air barriers via Building Science Digest 014, Air Flow Control in Buildings. For» AdditionAl InformatIon Author buildings, Maria Spinu, PhD, CSI, LEED AP, received her doctorate in polymer science from Virginia Tech and has worked with DuPont for two decades. She currently leads the Building Innovations group s building science and sustainability initiatives. Spinu is a member of the ASHRAE 90.1 Committee and envelope subcommittee, and has authored 15 patents. Spinu can be contacted via at [email protected]. Alan Learned, PhD, received his B.Sc. in Chemistry from Sterling College and his doctorate in organic chemistry from the University of Utah. In 1987, he joined DuPont, where he has received numerous awards and patents for new product, technology, and process development. Learned is currently the commercial technology development leader for the DuPont Building Innovations business. He can be contacted via at [email protected]. Abstract Air leakage is one of the factors significantly affecting HVAC energy use. This article reviews test methods and performance requirements for air barrier materials, assemblies, and whole further discussion on vapor permeability of air barriers and weather barriers, see co-author Spinu s article, To Be or Not to Be Vapor-permeable? in the April 2007 issue of The Construction Specifier. Visit and select Archives. 4 See National Institute of Standards and Technology Interagency Report (NISTIR) 7238, Investigation of the Impact of Commercial Building Envelope Airtightness on HVAC Energy Use, by Steven J. Emmerich, Tim McDowell, and Wagdy Anis. See also Airtightness of Commercial Buildings in the U.S., by Steven J. Emmerich and Andrew K. Persily and sponsored by DOE s Office of Building Technologies under Agreement No. DE-A01EE All equivalent wind speeds in this article should be considered as approximate. with special focus on testing of systems constructed with mechanically fastened membranes. Current ASTM methods show commercial-grade spun bonded polyolefin (SBP) membranes can outperform current requirements for air barrier assemblies when installed per the manufacturer. MasterFormat No Air Barriers UniFormat No. B2010 Exterior Wall Vapor Retarders, Air Barriers, and Insulation Key Words Division 07 Air barrier systems Air leakage ASTM International Building wrap Spun bonded polyolefin Contents of The Construction Specifier are copyrighted and are reproduced by Foster Printing Service with consent of Kenilworth Media Inc. The publisher and The Construction Specifications Institute shall not be liable for any of the views expressed by the authors, nor shall these opinions necessarily reflect those of the publisher and The Construction Specifications Institute. P: Tyvek W:
DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1
Building Science Bulletin DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1 and IECC Air Leakage Requirements When Tested in Accordance with ASTM E2357
UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS
UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS Executive Summary: There is a proposal at the Joint Committee on Administrative
Avoiding Air Barrier Pitfalls
Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT Rendered to: BEKAERT SPECIALTY FILMS, LLC SERIES/MODEL: Panorama 8-mil Film PRODUCT TYPE: Fixed Window with Applied Film This
Window Sill Details for Effective Drainage of Water
Construction Technology Update No. 76 Window Sill Details for Effective Drainage of Water By M.A. Lacasse and M.M. Armstrong Satisfactory window performance demands a good product and proper installation.
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems
PERFORMANCE TEST REPORT Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems Summary of Results Title Test Specimen #1 Test Specimen #2 Air Infiltration
DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines
DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines HELPING YOU GET THE JOB DONE RIGHT FOR BUILDINGS LESS THAN 5
Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction
T e c h n i c a l n o t e Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction Number J450 February 2009 Controlling against moisture damage in structures depends upon proper system
Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group
Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group Since water intrusion is among the most damaging problems
Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings
Best2 Airtightness of Buildings Session WB6-2 Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings Mario D. Gonçalves, Patenaude-Trempe and Robert Jutras, Air-Ins Introduction
DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING
TECH TALK DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING DuPont offers six different DuPont Tyvek building wraps intended for use on a wide range of buildings from single family homes to high
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Continuous Insulation Using Polyiso Wall Sheathing
PIMA Technical Bulletin #403 Continuous Insulation Using Polyiso Wall Sheathing What it is, what it does, and why you need it About Polyiso Insulation Polyiso is a rigid foam insulation used in over 70%
MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up
MOCK-UP TEST REPORT Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up Report No: 85616.01-120-32 Test Completion Date: 01/15/09 Report Date: 02/11/09 Record Retention End Date: 01/15/13
THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.
ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Comment Form on Proposed Gut Rehabilitation Alternatives
Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to [email protected] by October 10 th, 2012 with the subject line
How To Test For An Architectural Test
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System
Foundation. Foundation
Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their
TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana
Architectural Testing TEST REPORT Report No.: D0162.02-201-44 Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana PRODUCT TYPE: Pressure Equalized Rainscreen SERIES/MODEL: 4 mm Composite
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.
26 D+D MARCH 2015 Building Envelope Roland Serino, P.E., Dryvit Systems Inc. here has always been a need for a more efficient way to build in large cities like Chicago, New York, Los Angeles or other central
Water Damage & Repair
Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below
The Science of Rough Opening Preparation and Window Installation to Minimize Air Leakage
The Science of Rough Opening Preparation and Window Installation to Minimize Air Leakage Sam Hagerman, Hammer and Hand [email protected] Florian Speier, Zola Windows [email protected] Paul Grahovac,
PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall
Architectural Testing PERFORMANCE TEST REPORT Rendered to: UNITED STATES ALUMINUM CORPORATION SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall Title Summary of Results Air Infiltration
BEST 2 WB 3 4 SIX WAYS FOR CONDENSATION IN BUILDINGS. Wagdy Anis, FAIA, LEED ap*
BEST 2 WB 3 4 SIX WAYS FOR CONDENSATION IN BUILDINGS Wagdy Anis, FAIA, LEED ap* Abstract: Six of the ways condensation can occur on cold surfaces in buildings are discussed here. They are: 1. Air Leakage,
TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept
Architectural Testing TEST REPORT Report No.: A9814.01 109 44 Rendered to: BAMCO INC. Middlesex, New Jersey PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept AAMA 508 07, Voluntary Test Method
CONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
Building Envelope Design. ComfortBoard IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems
Building Envelope Design by Roxul Building Envelope Design by Roxul (BEDR ) ComfortBoard IS Exterior Insulated Sheathing for High-Performance Residential Wall Systems The Shore House North Vancouver, BC,
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses
INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS
INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
REPORT NUMBER: 100900226COQ-003 ORIGINAL ISSUE DATE: July 19, 2013
REPORT NUMBER: 100900226COQ-003 ORIGINAL ISSUE DATE: July 19, 2013 TEST REPORT EVALUATION CENTER INTERTEK TESTING SERVICES NA LTD. 1500 BRIGANTINE DRIVE COQUITLAM, BC V3K 7C1 CANADA RENDERED TO PHOENIX
Evaluation Report CCMC 13278-R MemBrain
Evaluation Report CCMC 13278-R MemBrain MasterFormat: 07 26 10.01 Issued: 2007-06-27 Re-evaluation: 2016-07-19 Re-evaluation due: 2019-06-27 1. Opinion It is the opinion of the Canadian Construction Materials
PERFORMANCE TEST REPORT. Rendered to: TREMCO INCORPORATED. SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly
PERFORMANCE TEST REPORT Rendered to: TREMCO INCORPORATED SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly Title Summary of Results Air Infiltration
How To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.
Dow Chemical is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members.
Presented by: Jennifer Doyle, P.E., RRC, LEED AP
Presented by: Jennifer Doyle, P.E., RRC, LEED AP Moisture Gas: Molecules are spread out "Vapor" suspended in air forms a mixture, present everywhere Liquid: Molecules are closer Rain Condensation Pipes
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
Enclosing Timber Frames. Panels. Frank Baker Founder, Riverbend Timber Framing and Insulspan
Enclosing Timber Frames with Structural Insulated Panels Frank Baker Founder, Riverbend Timber Framing and Insulspan Outline What are SIPs? Structural advantage of SIPs for timber frames Energy performance
PERFORMANCE EVALUATION OF THE CERAMITEX RVR SYSTEM IN ACCORDANCE WITH AAMA 508-07 FOR PRESSURE EQUALIZATION BEHAVIOR & WATER PENETRATION RESISTANCE
PERFORMANCE EVALUATION OF THE CERAMITEX RVR SYSTEM IN ACCORDANCE WITH AAMA 508-07 FOR PRESSURE EQUALIZATION BEHAVIOR & WATER PENETRATION RESISTANCE Report to: Ceramitex Inc. 520 Clarke Rd. London, Ontario
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: NORSE, INC. SERIES/MODEL: Flush Mount/Surface Mount PRODUCT TYPE: Hurricane Shutter Fastening System This report contains in its
Adding Brick Veneer to Existing Construction
TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 28A April 2008 Adding Brick Veneer to Construction Abstract: This Technical Note presents
Commercial Wall Designs using Continuous Insulation (CI) under Cladding BCBEC Vancouver and Victoria May 25 th & 26 th, 2011
Commercial Wall Designs using Continuous Insulation (CI) under Cladding BCBEC Vancouver and Victoria May 25 th & 26 th, 2011 Presenters: Les Yard and Scott Croasdale Global Sustainability Concerns Rising
LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council RETAINED ON U.S.
ICC-ES Legacy Report ER-5043* Reissued March 2004 www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code DIVISION: 09
2009 IECC Update. Scope. Content. International Energy Conservation Code
2009 IECC Update International Energy Conservation Code Scope The code applies to both residential and commercial buildings. In the code, the United States is divided into eight climate zones which are
Architectural Testing
FIELD AND MOCK-UP TESTING SERVICES 130 Derry Court York, PA 17406-8405 phone: 717-764-7700 fax: 717-764-4129 www.archtest.com Mock-up Test Methods (Laboratory Mock-up or Field Mock-up): ASTM E 283, Standard
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Lightweight Partition Design for Residential and Commercial Buildings
Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation
Brick Veneer/Steel Stud Walls
TECHNICAL NOTES on Brick Construction 28B 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703 620 0010 Brick Veneer/Steel Stud Walls Abstract: This Technical Note addresses the considerations
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
continuing professional education. As such, it construed to be an approval or endorsement by
This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
INFORMED MECHANICAL DESIGN THROUGH TESTED AIR LEAKAGE RATES. Jeff Speert, AIA MAIBC LEED AP
INFORMED MECHANICAL DESIGN THROUGH TESTED AIR LEAKAGE RATES Jeff Speert, AIA MAIBC LEED AP Background Move towards more energy efficient structures Collaborative approach promoted by LEED, 2030 Challenge,
2015 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY
MINNESOTA ENERGY CODE COMPLIANCE COLLABORATIVE 2015 Minnesota Residential Energy Code (MR 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY (July 15, 2015 Update) Note: The following information contains
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings
Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW RISE MULTI-FAMILY BUILDINGS LESS THAN 4 STORIES Tyvek
COMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
AAMA 2400-10. Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure
A M E R I C A N A R C H I T E C T U R A L AAMA 2400-10 Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure M A N U F A C T U
s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In
Family GUIDE FOR RESIDENTIAL applications Foamular Where quality and performance make a home The OWENS CORNING FOAMULAR XPS INSULATION FAMILY ALBUM is a critical feature of any home impacting overall comfort
Commercial Air Barrier Systems
Commercial Air Barrier Systems Building Envelope Systems Roofing I Air Barriers I Waterproofing The challenge is clear. The importance of air barriers The solution is here. The primary function of a building
Figure 1A. Typical brick veneer installation over wood frame construction.
Figure 1A. Typical brick veneer installation over wood frame construction. BACKGROUND In general, the description of any building, whether a high-rise or a warehouse, can be simplified into two basic components:
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar
Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW-RISE MULTI-FAMILY BUILDINGS
FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of
Technical Guide FOAMULAR Extruded Polystyrene Insulation For Cold Storage Applications FOAMULAR extruded polystyrene insulation is suitable for virtually all cold storage insulating needs, including floors,
The Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
Backstop NT. Backstop NT Specifications DS180. A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier
Backstop NT A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier Backstop NT Specifications DRYVIT SYSTEMS, INC. MANUFACTURER S SPECIFICATION CSI MASTERFORMAT SECTIONS
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider
ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider Report No.: Test Date: 5/21/07 Through: 5/23/07 Report Date: 5/30/07
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
SIGNIFICANT CHANGES to the 2015 Minnesota Residential Codes (MR 1303, 1309 and 1322)
SIGNIFICANT CHANGES to the 2015 Minnesota Residential Codes (MR 1303, 1309 and 1322) The following information contains simplified explanations of significant changes to the 2015 Requirements for Radon
EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money
EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links How to check for leaks Draftproofing products Sealants Draft proofing your home Draftproofing can be a cost-effective measure you take to
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
Vapor Permeability Provides No Performance Benefit for in Ventilated Attics
Vapor Permeability Provides No Performance Benefit for Roofing Underlayments in Ventilated Attics Testing Shows Breathable Underlayment Provides Little or No Moisture Transfer Value in Asphalt Roofing
WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:
WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS: BY WILLIAM D. SMITH Figure 1 Four Corporate Center, Franklin, TN. Architect: Little & Associates,Charlotte, NC. Gen. Contractor: Ray Bell Const. Co., Nashville,
BECx& Building Airtightness. Presented by: Eric Amhaus Principal
BECx& Building Airtightness Presented by: Eric Amhaus Principal The Building Enclosure 2007 study: out of 17,000 construction defect claims, 69% result of moisture related defects in building enclosure
PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Buffalo Forge Steel Doors / Round Top Single PRODUCT TYPE: In-swing Round Top Single Door RH-4 Title Uniform Load Deflection Test
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)
PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.
PERFORMANCE TEST REPORT Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC. SERIES/MODEL: AMS ARMOR-LOCK PRODUCT TYPE: STANDING SEAM METAL ROOF PANEL SYSTEM Report No: 97123.02-901-44 Test Date: 05/17/10
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
ST. MONICA FOOD PANTRY HOUSTON, TEXAS
PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,
Natatorium Building Enclosure Deterioration Due to Moisture Migration
Buildings 2012, 2, 534-541; doi:10.3390/buildings2040534 OPEN ACCESS buildings ISSN 2075-5309 www.mdpi.com/journal/buildings/ Case Study Natatorium Building Enclosure Deterioration Due to Moisture Migration
SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request
SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table