Product catalogue 2012 rev 1 kat g Smart indoor climate!
|
|
- Berenice Johnson
- 7 years ago
- Views:
Transcription
1 Product catalogue 2012 rev 1 Smart indoor climate!.2
2
3 Table of contents Wireless control system examples... p. 4 Wireless rooom temperature control systems... p. 5-7 Wireless room temperature control systems Room temperature control system examples... p. 8-9 Thermostats and room temperature controllers... p Room temperature controllers ontrol unit system examples... p. 14 ontrol units... p ontrol units Room units E121, E122, E123, E201 and E p. 17 Room units onfiguration tools H202 and H p. 18 onfiguration tools Sensors G9, G21, G22, G23 and G24... p. 19 Sensors GIR-1, GIR-2 and G-O2... p. 20 Sensors Actuators and valve adapters... p. 21 Actuators and valve adapters Damper actuators... p. 22 Damper actuators 2-port control valves with firm and adjustable kvs-value... p port valves 3-port valves... p port valves Shut off, trim, terminal and differential pressure valves... p. 24 Misc. valves Valve connections... p. 25 Valve connections Transformers and cables for Zone ontrols systems... p. 26 Transformers and cables Relay units for Zone ontrols systems... p. 27 Relay units
4 SET wireless Systems system examples System example 1 WA alt. 230V A These are only system examples of how the products can be used. ontact us for additional examples or functions. WRU WA alt. 230V A ontrol cooling and heating in sequence with room unit WRU and actuator unit WA. System example 2 WF 230V A WRU-F Key card switch Window contact switch WA Floor temperature sensor ontrol cooling, heating, fan speed and heated floor in sequence with room unit WRUF, control unit WA and WF. The key card switch/window contact switches the current operation mode between economy and comfort operation mode. The control unit WA controls the heated floor dependeing of the total power requirement of the room. p. 4
5 WIRELESS systems Description, room unit WRU Wireless room unit for measuring the room temperature and adjusting the set-point. Available for fan speed control, timer forced ventilation, and without set-point knob. Radio communication. Easy installation. The solar cell powered room unit is without any cables. Powered by solar cell or. Built in temperature sensor. Available in aluminium or steel grey enclosure, standard colour is white. E approved. WRU WRUF WRUT Room unit solar cell powered Room unit without set-point knob WTS WTS Room unit WRU WRU Room unit with button for fan speed control WRUF WRU24F Room unit with timer button WRUT WRU24T Description, actuator unit WA Wireless actuator unit to control one actuator on a control valve Radio communication. Powered with or 230V A. To be used with actuators in the AT-series. E approved. Actuator unit 230V A Actuator unit WA WA p. 5
6 WIRELESS SystemS Description, control unit WA ontrol unit for the wireless system, control cooling, heating and ventilation. For controlling of chilled ceilings, radiators etc. Effective and energy saving control. PI-control. ooling and heating in sequence. Available in two performances: - WA Supply voltage 24 V A, 2 digital and 1 analog output. - WA Supply voltage 230 V A, 2 digital outputs. 2 inputs for e.g. temperature sensor and occupancy detector. The inputs can be adjusted between different levels and purposes. Automatic valve exersice. Timer function for overriding the operation mode or to force output. Wireless room unit WRU can be connected by radio communication. ontrol values can be monitored and overriden with a building management system by a gateway WSG. E approved. The control units control parametres, inputs, output signals etc. can easily be customized and installed with the WPG configuration tool. ontrol unit WA Supply voltage, 2 digital and 1 analog output Supply voltage 230V A, 2 digital outputs WA-24 WA-230 Description, control unit WF ontrol unit for the wireless system, control cooling, heating and fan speed. For controlling of fan coils, chilled ceilings, radiators etc. Effective and energy saving control. PI-control. ooling and heating in sequence. Two actuator outputs (230V or 24V depending on the model WF ). Three relay outputs for fan speed control (WF-230 only). One 0-10V output for fan coil control with an E-motor (WF-10 only). 2 inputs for e.g. temperature sensor and occupancy detector. The inputs can be adjusted between different levels and purposes. Automatic valve exersice. Timer function for overriding the operation mode or to force output. Wireless room unit WRU can be connected by radio communication. ontrol values can be monitored and overriden with a building management system by a gateway WSG. E approved. The control units control parametres, inputs, output signals etc. can be customized especially for an installation with the WPG configuration tool. ontrol unit WF Supply voltage, 2 digital and 1 analog output Supply voltage 230V A, 2 digital outputs WF-10 WF-230 p. 6
7 Wireless systems Description, gateway WSG Used for supervision, measuring and to confiure wireless products, and as a connection point for a supervision system. Radio communication. Ethernet 10/100 Mbit (RJ45). Modbus RTU over TP/IP. E-approved. Wireless gateway WSG Description, configuration tool WPG Used with a windows P to install and configure the wireless products (WRU, WA, WF and WA). E approved. WM WPG onfiguration tool Windows program WM (enclosed with WPG) WPG WM p. 7
8 ROOM TEMPERATURE ONTROLLERS system examples System example 1 AT actuator 0-10V / (max 8 pcs total) These are only system examples of how the products can be used. ontact us for additional examples or functions. ondensation sensor G9 ontroller R102 ontroller R201 AT actuator 0-10V / (max 8 pcs total) ontrol cooling and heating in sequence with room temperature controller R102 or R201. System example 2 AT actuator (max 8 pcs total) SBA / SB damper actuator 0-10V D / Occupancy detector GIR-1 ontroller RS102 ontroller R221 AT actuator AT actuator (max 8 pcs total) ontrols cooling, heating and damper actuator in sequence with room temperature controller RS102 or R221. The occupancy detector switches the controllers operation mode between economy and comfort operation mode. Forced ventilation (2h time period) when the forced ventilation button is pressed on the controller RS102. p. 8
9 Room Thermostat controls with actuators Description, room thermostat R41 A analog room thermostat to control cooling and heating with on/off output signals. The room thermostat is available with terminal or modular connections. For controlling of chilled ceilings, radiators etc. ooling and heating in sequence with 24V on/off. The temperature can be adjusted from 16 to 28. The LED indicates actual operation status. Protection class IP20. Size: 77 x 77 x 27 mm. E-approved. System description The picture shows a typical system with room thermostat R41. ooling and heating in sequence with 24V on/off outputs. Maximum of 4 actuators per output. On room thermostat R41e, an external room temperature sensor can be connected if needed. 230V A Transformer Room thermostat H (External temp. sensor) 24V ooling 24V Heating The picture shows a typical system with room thermostat with modular connection and modular cable, actuator with modular contacts and D1-2 connection boxes. See product data sheet for further descriptions of modular cables and actuators. 230V A ooling and heating in sequence with 24V outputs. Maximum of 4 actuators per output. Room thermostat onnection boxes Transformer H H ooling Heating ooling Heating ARTIKELNUMMER Room thermostat R41 cooling output Heating output R on/off on/off R41e (for external temp. sensor) on/off on/off R41M (modular connection) on/off on/off Transformer for R41M T20-21M p. 9
10 ontrollers controls with and 0-10V actuators Description, controller R102 A digital room temperature controller for control of cooling and heating. The controllers output signal functions can easily be changed with the jumpers on the circuit board. The controller is available with terminal or modular connection. For controlling of chilled ceilings, radiators etc. Effective and energy saving control. ooling and heating in sequence with time proportional 24V on/off and/or analog 0-10V outputs. The temperature can be adjusted from 19 to 25. The LED indicates actual operating status. Protection class IP20. Size: 77 x 77 x 27 mm. E-approved and S-marked. The control parameters, inputs and output signals and limit values can be adjusted with help of a configuration unit, which connects to the controller with a modular contact under the controllers cover plate. System description The picture shows a typical system with room temperature controller R102 and its in- and outputs as they are configured on delivery. The inputs are programmable to fit different types of sensors: External temperature sensor Occupancy sensor ontact for overriding the operation mode ondensation sensor The output functions, sequences and limit values can easily be adjusted with a configuration unit H202. The room temperature controller can be ordered preinstalled with customer specific parameters. ontact Zone ontrols AB for more information. Room temperature controller ondensation sensor External temp. sensor 230V A Transformer ooling actuators H Heating actuators The picture shows a typical system with room temperature controller R102M in modular performance with modular cable, actuator with modular contacts and D1-2 connection boxes. See product data sheet for further descriptions of modular cables and actuators. The room temperature controller can be ordered preinstalled with customer specific parameters. ontact Zone ontrols AB for more information. Room temperature controller onnection box 230V A Transformer H H ooling Heating ooling Heating ontroller heating output ooling output R R V D 0-10V D R V D R V D R102M (modular connections e.g. R102M ) onfiguration unit H Transformer for R102M T20-21M p. 10
11 Description, controller RS102 A digital room temperature controller for controlling cooling and heating, with a button to force a ventilation damper to open in 2 hours. The forcing output of the damper can also be adjusted to control in sequence with the cooling output. The controllers output signal functions can easily be changed with the jumpers on the circuit board. For controlling of chilled ceilings, radiators etc. Effective and energy saving control. ooling and heating in sequence with time proportional 24V on/off and/or analog 0-10V outputs. Push-button to set the forcing function on/off. Forcing indication with LED. The temperature can be adjusted from 19 to 25. LED indicates current operation mode. Protection class IP20. Size: 77 x 77 x 27 mm. E-approved. The control parameters, inputs and output signals and limit values can be adjusted with help of a configuration unit, which connects to the controller with a modular contact under the controllers cover plate. ONTROLLERS ONTROLs AND 0-10V ATUATORS AND FORED VENTILATION System description The picture shows a typical system with room temperature controller RS102 and its in- and outputs as they are configured on delivery. The input is adapted for an optional temperature sensor, connected when in need of an optimal placement of a room temperature sensor. The outputs functions, sequences and limit values can easily be adjusted with a configuration unit H202. The room temperature controller can be ordered preinstalled with customer specific parameters. ontact Zone ontrols AB for more information. Room temperature controller External temp. sensor 230V A Transformer D Damper actuator ooling actuator H Heating actuator ontroller heating output ooling output Forced ventilation RS V D onfiguation unit H p. 11
12 ontroller with display controls with and 0-10V actuators Description, controller R221 and R222 A digital room temperature controller for controlling cooling and heating. Modbus communication or stand alone. The control parametres, input and output signals and control limitation values can be adjusted directly with the display and buttons. No separate configuration unit is necessary. The R222 controller is designed to control the fan speed with the 0-10V output via a 3 stage relay or an E motor in 3 steps, or seamless. For controlling of chilled ceilings, radiators etc. PI-control, effective and energy saving. ooling and heating in sequence with time proportional 24V on/off and/or analogue 0-10V output. an also control raise/lower actuators (3 point control). The temperature can be adjusted from 19 to 25. The display indicates actual operating status. Protection class IP30. Size : 89 x 89 x 26mm. E approved System description The picture shows a typical system with room temperature controller R221 and its in- and outputs as they are configured on delivery. The inputs are programmable to suit different types of sensors: External temperature sensor Occupancy sensor ontact for overriding the operation mode ondensation sensor The output functions, sequences and limit values can easily be adjusted with the help of the controllers buttons and display. The room temperature controller can be ordered preinstalled with customer specific parameters. ontact Zone ontrols AB for more information. The picture shows a typical system with room temperature controller R222 and its in- and outputs as they are configured on delivery. The inputs are programmable to suit different types of sensors: External temperature sensor Occupancy sensor ontact for overriding the operation mode ondensation sensor The output functions, sequences and limit values can easily be adjusted with the help of the controllers buttons and display. The 0-10V output can be activated to control a 0-10V relay for fan speed control, an E motor in 3 stages or seamless. The room temperature controller can be ordered preinstalled with customer specific parameters. ontact Zone ontrols AB for more information. R Room temperature controller Modbus Timer switch to force output 230V A External temperature sensor Transformer ooling ( 0-10V D ) ooling ( ) H Heating ( ) G Heating ( ) R Room temperature controller 230V A Transformer F Modbus Timer switch to force output External temperature sensor Seamless, or 3 stage output for fan speed control (0-10V D) ooling ( ) H Heating ( ) H Heating ( ) ontroller R R (for 0-10V D fan speed control) p. 12
13 ONTROLLER WITH DISPLAY ONTROLS WITH AND 0-10V ATUATORS Description, controller R A digital room temperature controller with an infrared receiver for built-in mounting in e.g. chilled beams. The infrared receiver in the controller makes it possible to easily adjust values when the controller has been mounted in an unapproachable place, e.g. the ceilings. hanges of walls placements does not affect the zoning of the chilled beams. An external sensor measures the room temperature in the ejected air. ontrol parameters, inputs and so on can be adjusted with the help of the controllers display and a remote control. For controlling of chilled ceilings, radiators etc. Effective and energy saving control. Input for a forcing button. Automatic valve exercise. Possibility to block IR-receiving with a 4-digit code. ooling and heating with several steps in sequence (see system description). The temperature can be adjusted from 19 to 25. The display indicates actual operating status. Protection class IP30. Size: 89 x 89 x 26 mm. E-approved. System description R Room temperature controller 230V A Transformer Switch to force cooling 1 (0-10V). External temperature sensor ooling 1 ( ) ooling 1 ( 0-10V D ) ooling 2 ( ) R is available in three different standard performances. The pictures shows all three systems and its in and outputs as they are configured on delivery. The output functions, sequences and limit values can easily be adjusted with the help of the controllers display and a remote control.. The room temperature controller can be ordered pre-installed with customer specific parameters. ontact Zone ontrols AB for more information. R Room temperature controller Switch to force cooling 1 (0-10V). External temperature sensor 230V A Transformer H ooling 1 ( 0-10V D ) ooling 2 ( ) Heating ( ) R Room temperature controller Switch to force cooling 1 (0-10V). External temperature sensor 230V A Transformer ooling 1 ( ) ooling 2 ( ) Room temperature controller output 1 output 2 output 3 R ooling 1 ( 24V ) ooling 1 (0-10V) ooling 2 (24V) R ooling 1 ( 0-10V ) ooling 2 ( 24V ) Heating ( 24V ) R ooling 1 ( 24V ) ooling 2 ( 24V ) - Remote control H11 p. 13
14 ontrol units System examples System example 1 SBA / SA damper actuator 0-10V D SBA / SA damper actuator 0-10V D These are only system examples of how the products can be used. ontact us for additional examples or functions. Room unit E201 AT actuator (max 8 pcs total) ondensation sensor ModBus 221 Room unit E101 Room unit E123 AT actuator AT actuator Occupancy detector GIR-1 O2 sensor G-O2 AT actuator (max 8 pcs total) For controlling of cooling, heating and ventilation in sequence with control unit 221 and room unit E201, E121 or E123. The occupancy detector contact switches the current operation mode between economy and comfort operation mode. The O2-sensor forces the damper actuators to open for ventilation when the O2 levels are too high. The forced ventilation can also be controlled by a timer with room unit E123. The system can be connected to Modbus. System example 2 SBA / SB damper actuator 0-10V D / Room unit E202 AT actuator ModBus Room unit E AT actuator RL203 Fan coil Heated floor in the bathroom AT actuator 0-10V D Key card switch GK-01 Window contact switch Floor temperature sensor G231 For controlling of cooling, heating, ventilation and a fan coil in sequence with control unit 222 and room unit E202 or E122. The key card switch/window contact switches the current operation mode between economy and comfort operation mode. The damper actuator output is only active if the controller is in the comfort operation mode. The control unit 222 with the floor temperature sensor controls the heated floor depending of the total power requirement of the room. The system can be connected to Modbus. p. 14
15 ONTROL UNITS ONTROLS WITH AND 0-10V ATUATORS Description, control unit 221 och and 222 Intelligent and flexible control units for most types of applications. Effective and energy saving control. ommunication via ModBus or stand alone. The control units control parameters, input and output signals etc. can be adjusted with a room unit E201/E202 or a configuration unit H203. Used as a supply unit for room units in the E series and control unit for actuators. Galvanic isolated communication circuit for ModBus communication The in- and outputs can be adjusted between different signal levels and purposes 3 programmable inputs for different types of sensors 4 programmable outputs: 2 pcs. of outputs + 2 pcs. of 0-10V outputs Automatic valve exercise Timer function for overriding the operation mode or to force outputs Pluggable terminals for easier installation One control unit can control upto 16 slave control units. 221 is expandable with relay unit RL203 to control dampers in 3 steps. It can also control fan speed with the 0-10V output e.g. E motor in 3 steps or seamless. 222 is expandable with relay unit RL203 to control fan speeds in 3 steps. Supply voltage:. Protection class IP44. Size: 80 x 122 x 40 mm. E approved. The room units in the E series are available in different performances for various site specific functions. System description The picture shows the control units all available in- and outputs as they are configured on delivery. All inputs are programmable to fit different types of sensors, e.g: Room unit I1.External temp. sensor Temperature sensor control (control 0-10V or thermistor). Secondary temperature sensor Occupancy sensor ontact for overriding the operation mode General 0-10V sensor ondensation sensor The inputs can also be programmed to directly influence one of the outputs. Modular cable 220V A Transformaer ontrol unit H H I2.ontact/Economy control I3.ondensation sensor ModBus 24V output (cooling) 24V output (heating) 0-10V output (cooling) The control units outputs are programmable to fit most types of actuators. The output functions, sequences and limit values can easily be adjusted with a room unit E201 or a configuration unit H203. The control unit can be expanded with a relay unit RL203 to control damper outputs or fan speeds: 221 and RL203 are used to control dampers up to three steps in sequence. It can also control fan speed with the 0-10V ouput e.g. an E motor. 220V A Transformer Relay unit 0-10V output (heating) Fan- or damper output 1 Fan- or damper output 2 Fan- or damper output and RL203 are used to control fan speeds upto three steps in sequence. The control unit can be ordered pre-installed with customer specific parameters. ontact Zone ontrols AB for more information. ontrol unit for chilled ceilings, radiators, dampers etc for fan coil control Relay unit to control dampers or fan speeds in 3 steps RL p. 15
16 ONTROL UNIT ONTROLS WITH TUATORS Description, control unit 202 A control unit for controlling cooling and heating. ontrol unit 202 can be used together with relay unit RL203 to control fan speeds in three steps. Effective and energy saving control. The control units control parameters, input and output signals etc. can be adjusted with a room unit E201/E202 or a configuration unit H203. Used as a supply unit for room units in the E series and control unit for actuators. 202 is expandable with relay unit RL203 to control fan speeds in three steps. The in- and outputs can be adjusted between different signal levels and purposes. 1 programmable input for different types of sensors. 2 programmable outputs. Automatic valve exercise Timer function for overriding the operation mode or to force outputs. Supply voltage:. Protection class IP44. Size: 80 x 122 x 40 mm. E-approved. The room units in the E series are available in different performances for various site specific functions. See next page. System description The picture shows the control units all available in- and outputs as they are configured on delivery. The input is programmable to fit different types of sensors, e.g: Room unit External temperature sensor External temperature sensor Occupancy sensor ontact for overriding the operation mode ondensation sensor The control units outputs are programmable to fit most types of 24V actuators. The output functions, sequences and limit values can easily be adjusted with a room unit E201/E202 or a configuration unit H203. Modular cable 220V A Transformer ontrol unit H 24V output (cooling) 24V output (heating) The control unit can be ordered pre-installed with customer specific parameters. ontact Zone ontrols AB for information. Relay unit Fan speed 1 Fan speed 2 Fan speed 3 ontrol unit for chilled ceilings, radiators, fan coil controls etc. 202B (controls the fan speed only in cooling mode) Relay unit to control fan speeds in three steps RL p. 16
17 ROOM UNITS TO ONNET TO THE ONTROL UNIT Description, room unit E121 A room unit with knob to control temperature. It has a built-in temperature sensor which measures the current room temperature. The LED indicates current function. In need of cooling a blue LED is lit, red in need of heating and is off at dead zone. If a condensation sensor is connected the blue LED flashes at condensation. onnects to control unit 221 with a 4-way cable (K400) Protection class IP30. Size: 77 x 77 x 27 mm. E approved. Room unit E Description, room unit E122 A room unit with knob to control temperature and a button to control fan speed or damper output. It has a built-in temperature sensor which measures current room temperature. The LEDs indicates current function. If a condensation sensor is connected the blue LED flashes at condensation.. The LEDs closest to the button indicates actual fan/damper function. onnects to control unit 221 or 222 with a 4-way cable (K400) Protection class IP30. Size: 77 x 77 x 27 mm. E approved. Room unit E Description, room unit E123 A room unit with knob to control temperature and a button to control time of timer, e.g. forced ventilation. It has a built-in temperature sensor which measures current room temperature. The LEDs indicates current function. If a condensation sensor is connected the blue LED flashes at condensation. The LEDs closest to the button indicates remaining time of timer. onnects to control unit 221 or 222 with a 4-way cable (K400) Protection class IP30. Size: 77 x 77 x 27 mm. E approved. Room unit E Description, room unit E201 / E202 E201 is a room unit with display and buttons to control room temperature. Built-in menu system to control all of the control unit s functions. It has a built-in temperature sensor which measures current room temperature. The display shows current function, temperatures and set points. E202 also has an extra button function to adjust fan speed (or damper outputs). onnects to control unit 221 or 222 with a 4-wire modular cable (K43) Protection class IP30. Size: 89 x 89 x 26 mm. E-approved. Room unit E E (to control fans or dampers). p. 17
18 ONFIGURATION UNITS for configuration of ontrollers and control units Description, configuration unit H202 / H203 Used for setting control parameters, input and output signals etc. The configuration units are connected to a digital controller without display or to a room unit without display. The connection to the controller or room unit is done with a modular contact. H202 is used together with room temperature controller R102 H203 is used together with room unit E121-E123, or connected directly to a control unit. Quick connection with a modular contact. Protection class IP30. Size: 89 x 89 x 26 mm. E-approved. onfiguration units H for R102 H for E121-E123 or control unit 221 and 222 p. 18
19 Duct sensor Duct sensors can be used when you need to measure the temperature of the supplied or ejected air. It is available in performances for both the analog and digital controllers, see order number below. Sensors FoR controllers and control units Sensor G3 G23 suitable for (to analog control systems) (to digital control systems) Room temperature sensor Room temperature sensors can be used when the temperature shall be measured in a room, to control mean value, for instance, or if you want the controller to be hidden. It is available in performances for both the analog and digital controllers, see order number below. Sensor G4 G24 suitable for (to analog control systems) (to digital control systems) ondensation sensor ondensation sensors can be used if you want the output signal of the cooling to be blocked or that a relay shuts at condensation. The condensation sensor is adhesive and should be mounted on the underside of pipes or other places where condensation may occur. Sensor G9 Pipe surface temperature sensor The pipe surface temperature sensor can be used when the water temperature shall be measured in systems with a heating controller. The pipe surface temperature sensor shall be mounted on the top side of the pipe with the included stripe. Sensor G p. 19
20 SENSORS FoR controllers and control units Occupancy detector For occupancy detection in office rooms or other indoor areas. Designed for mounting at the ceiling. The occupancy detector reacts on sudden temperature changes in the room. Adjustable on/off-delay. E approved. Occupancy detector GIR-1 Occupancy detector For occupancy detection in office rooms or other indoor areas. Designed for wall mounting. The occupancy detector reacts on sudden temperature changes in the room. Adjustable on/off-delay. E approved. Occupancy detector GIR-2 O2 sensor For measuring of O2 and temperature levels in offices, conference rooms etc. O2 sensors can be used with the control units to force, or control exhaust and supply air dampers when the O2 levels are too high. The sensor measures O2 levels between ppm, and the output voltage 0-10V in proportion to the rooms ppm value. The O2 sensor also has a built in active temperature sensor and the output voltage is 0-10V in proportion to the room temperature. Available in performaces with or without display and with Modbus communication. The O2 sensors are self calibrating. Also available in special versions for VAV control. ontact Zone ontrols AB for more information. E approved. O2 sensors Without display With display O2 sensor without Mobus G-O2 G-O2D O2 sensor with Modbus G-O2M G-O2DM p. 20
21 ATUATORS AND VALVE ADAPTERS Actuators Actuator AT with many connection possibilities and functions: Order number Function Performace Picture AT-0 N Without cable A AT-1 N With 1 m cable A AT-2 NO With 1 m cable A AT-3 230V A N With 1 m cable A AT-4 230V A NO With 1 m cable A A Accessories Picture AT-K1 1 m connection cable to AT-0 AT-K V cable to AT-0, 2 m AT-K0-10-5M 0-10V cable to AT-0, 5 m AT-K V cable to AT-2, 2 m AT-28MMA Bayonet nut for MMA actuators B Bayonet nut for M28x1,5mm actuators Bayonet nut for M30x1,5mm actuators D B D Valve adapters To get the actuators to fit on valves of different brands you sometimes need an valve adapter. Zone ontrols have valve adapters to most of the existing valves on the market. For actuators with M28 x 1,5 mm thread fitting: Order number onnection Inner diameter Fits valve: Hex. set screw 20 mm Danfoss RAN Hex. set screw 25,5 mm Danfoss RAVL Hex. set screw 34 mm Danfoss RAV Thread M20 x 1 AGA Thread M30 x 1,5 TA/HEIMEIER Thread M28 x 1,5 TA RVT Thread M28 x 1,5 EPEON For actuators with M30 x 1,5 mm thread fitting: Order number onnection Inner diameter Fits valve: Thread M20 x 1 AGA Hex. set screw 20 mm Danfoss RAN Hex. set screw 25,5 mm Danfoss RAVL Hex. set screw 34 mm Danfoss RAV Thread M28 x 1,5 Markaryd Thread M30 x 1,5 Landis & Gyr Thread M28 x 1,5 TA RVT/TRV Thread M28 x 1,5 EPEON p. 21
22 DAMPER ATUATORS Damper actuator SA Rotation angle SA2224 is designed for use on smaller round dampers but can also be used in other dampers with a maximum area of 0.2 m2, however, the safety margin has to be to the maximum rotary torque of 2 Nm. The motor rotates counter clockwise as seen from shaft side and is not reversible. It is delivered in a closed position. Several damper actuators can be connected in parallel. Different mounting plates are available for different damper solutions. Damper actuator Torque control voltage SA Nm Damper actuator SB SB2 is a series of damper actuators that are available in two sizes, 2 and 4 Nm. The supply voltage is 24 V A/D or 230 V A. The damper actuators has synchronous motors for reversible control and magnetic end position break. The W-W switch changes the rotation direction. Push-button for gearing release. Damper actuator Torque control voltage SB2224 / SB / 4 Nm SB22230 / SB / 4 Nm 230V A SBA224 / SBA424 2 / 4 Nm 0-10V D Damper actuator S S2 is a series of damper actuators that are available in two sizes, 6 and 10 Nm. The supply voltage is 24 V A/D or 230 V A. The SA damper actuator can be controlled with a 0-10V output signal. The damper actuators has synchronous motors for reversible control and magnetic end position break. The W-W switch changes the rotation direction. Push-button for gearing release. Damper actuator Torque control voltage S2624 / S / 10 Nm S26230 / S / 10 Nm 230V A SA624 / SA / 10 Nm 0-10V D Damper actuator SF SF2 is a 2-position damper actuator with spring-return. The supply voltage is 24 V A/D. The damper actuators has synchronous motors and magnetic end position break. Manual opening and locking of the spring-return. Damper actuator Torque control voltage SF Nm SF Nm p. 22
23 VALVES 2 port valves with firm kvs value The valves are available in different performances, sizes and with various kvs-values, dependent on the size of the pipe. More information of the valves and pressure drop diagrams are available on our website A B Ord.number onnection Type Pic kvs-values Thread (actuators) 2201 DN10 - DN20 Angled A 1,25 / 1,35 M30x1,5 mm 2202 DN10 - DN32 Straight B 1,25 / 5,80 M30x1,5 mm 2242 DN15 - DN20 Straight 2,50 / 3,60 M30x1,5 mm M002 DN10 - DN15 Straight D 1,20 / 1,40 M28x1,5 mm M242 DN10 - DN20 Straight E 2,50 / 3,90 M28x1,5 mm D E 2 port valves with adjustable kvs value The valves are available in different performances, sizes and with various kvs-values, dependent on the size of the pipe. More information of the valves and pressure drop diagrams are available on our website Ord.number onnection Type Pic kvs-values Thread (actuators) 3511 DN10 - DN15 Angled A 0,05-0,73 M30x1,5 mm 3512 DN10 - DN20 Straight B 0,05-0,73 M30x1,5 mm M501 DN10 - DN20 Straight 0,01-1,20 M28x1,5 mm M502 DN10 - DN20 Straight D 0,01-1,20 M28x1,5 mm DZR* M552 DN15 - DN20 Straight E 0,01-3,60 M28x1,5 mm * ) DZR = Dezincification resistant brass A B D E p. 23
24 VALVES 3 port valves A The valves are available in different performances, sizes and with various kvs-values, dependent on the size of the pipe. More information of the valves and pressure drop diagrams are available on our website B Ord.number onnection Pic kvs-values Thread (actuators) DN15 A 1,45 M m30x1,5 mm 4160 DN15 - DN25 B 2,47 / 5,12 m30x1,5 mm M139 DN15 1,50 M m28x1,5 mm M160 DN15 - DN25 D 2,00 / 5,00 m28x1,5 mm D A Other valves B The valves are available in different performances, sizes and with various kvs-values, dependent on the size of the pipe. More information of the valves and pressure drop diagrams are available on our website Trim valves Ord.number onnection Type Pic kvs-values 0352 DN10 - DN20 Straight A 0,09-1,31 M312 DN10 - DN32 Straight B 0,03-1,30 D Shutting valve Ord.number onnection Type Pic kvs-values 0600 DN10 - DN20 Straight 6,00-14,00 E Differential pressure valve Ord.number onnection Type Pic 5501 DN20 - DN32 Angled D Terminal valve TBV- Ord.number onnection Type Pic kvs-values Thread (actuators) 1502 DN15 - DN20 Angled E 0,22-3,4 M30x1,5 mm p. 24
25 VentilKOPPLINGAR onnections for valves onnections, valves manufactured by Heimeier ( ord.nr from ). A Ord.number onnection ø pipe Pic Type DN15 1/2 A Straight, thread connection and nut DN20 3/4 A Straight, thread connection and nut DN25 1 A Straight, thread connection and nut DN10 10mm B Pressure screw and cone DN15 10mm B Pressure screw and cone DN15 12mm B Pressure screw and cone DN15 15mm B Pressure screw and cone B DN10 DN10 12mm Pressure nut and cone DN15 10mm Pressure nut and cone DN15 12mm Pressure nut and cone DN15 15mm Pressure nut and cone onnections for valves M002 - M552 onnections, valves manufactured by Markaryd ( ord.nr from M002 - M552 ). Ord.number onnection ø pipe Pic Type M DN10 - A Straight, thread connection and nut M DN15 - A Straight, thread connection and nut M DN15 - A Straight, thread connection and nut DZR* M DN20 - A Straight, thread connection and nut M DN10 - B urve and nut M DN15 - B urve and nut M DN20 - B urve and nut M DN10 10mm Pressure screw and cone M DN10 12mm Pressure screw and cone M DN15 12mm Pressure screw and cone M DN15 15mm Pressure screw and cone DZR* M DN10 12mm D Pressure nut M DN10 15mm D Pressure nut M DN15 15mm D Pressure nut DZR* M DN15 15mm E Push-on connection M DN15 15mm E Push-on connection A B onnections for 3-port valves: M DN15 10mm F Pressure nut M DN15 12mm F Pressure nut M DN20 12mm F Pressure nut M DN20 22mm F Pressure nut D * ) DZR = Dezincification resistant brass F E p. 25
26 Transformers and ABLES transformers and ABLES for zone controls systems Transformers All transformers are supplied with 230V A. E approved Technical data T20 T28 T40 T60 T120 T220 Supply voltage 230V A 230V A 230V A 230V A 230V A 230V A Output voltage Power 20 VA 28 VA 40 VA 60 VA 120 VA 220 VA Fuse, secondary pt 40 PT 25 1,6 A 2,5 A - - Fuse, primary ,7 A 1,5 A onnection, primary Wall socket able Terminal Terminal Terminal Terminal onnection, secondary able able Terminal Terminal Terminal Terminal Protection class IP44 IP44 IP44 IP44 IP44 IP44 Transformer cabinet SK10 The transformer is supplied with 230V A. E approved. Technical data Supply voltage...230v A Output voltage...4 x Power VA Automatic fuse...10 A onnection, primary...terminals for cable 2,5 mm 2 onnection, secondary...terminals for cablel 2,5 mm 2 Size (w x h x d) x 290 x 115 ables and accessories ables can be ordered in different performances depending on lenght, number of conductors and colours. Standard colour is white We recommend that modular cables used for our products are purchased from us, or made from parts recommended by us, so that a correct function can be guaranteed. onnection cable from a control unit to a room unit and communication cable for modbus Order number Areas of use # of conductors able type olour K400 onnection cable 4 pcs. (2 pairs) Twisted pair/unshielded White K410 ommunication cable 4 pcs. (2 pairs) Twisted pair/unshielded Grey Specify cable lenght after order number, e.g. K400-3M (3 meters). They are delivered pre-cutted (not peeled) from roll. Modular cable for connecting control unit 221/222 with room unit E201 Technical data K43 # of conductors, cable 4 # of conductors, modular contact 4/4 Specify cable length after order number, e.g. K43-3M (3 meters) Extension jacks for modular cables Technical data KR-4/4 KY-4/4 KR-6/6 KY-6/6 KR-8/8 KY-8/8 Type Straight Y-unit Straight Y-unit Straight Y-unit onnections 4/4+4/4 4/4+4/4+4/4 6/6+6/6 6/6+6/6+6/6 8/8+8/8 8/8+8/8+8/8 p. 26
27 relay UNITS Relay units Relay units for digital and analog systems onnections...terminals Protection class...ip44 Size...80 x 122 x 40 mm Relay unit RL203 is used together with the control units in the 200-series to control the fan speeds or dampers in three steps. Demands supply voltage and control signal from control unit. E approved. L RY1 RY2 RY3 Relay 1 Relay 2 Relay 3 Relay unit RL Relay unit RL1 has one relay with different switching functions and is used to control electric heating, for instance. The relay can be controlled with or 230V A. E approved Relay Relay unit RL1-24V RL1-230V control signal 230V A Relay unit RL3 has three relays to amplify the fan speed signals for control systems with fan speed control, or electric heating control. The relay can be controlled with or 230V A. E approved Relay Relay Relay Relay unit RL3-24V RL3-230V control signal 230V A Relay unit RL21 has one relay with switching function, used by systems with change-over function. The relay can be controlled with 24V A or 230V A. E approved N 8 NO 7 6 om Relay Relay unit RL21-24V RL21-230V control signal 230V A Relay unit RL70 is used for transforming a 0-10 D signal to a potential free contact. Reuires supply voltage and a 0-10V D control signal. The relays hysteresis and contact point can be adjusted. E approved. Relay unit RL70 Relay unit RL70 is used for transforming a 0-10 D signal to three potential free contacts for fan coil speed control. Reuires 24V A supply voltage and a 0-10V D control signal. The relays hysteresis and contact pointa can be adjusted individually for all three relays. E approved. Relay unit RL80 Triac unit TR V is used to control electric heating together with Zone ontrols control systems. The triac unit is controlled with a 0-10V D pwm-signal from a controller/control unit. E-approved. Triac unit TR V p. 27
28 If there s a possibility - We have the solution! Zone ontrols AB develops, manufactures and markets control equipment for different types of control systems e.g. chilled ceilings, radiators, fan coils, VAV, floor heating and combinations of various system types. Our products distinguish by their flexible construction. You will find over 150 standard system solutions. There is always a solution for you as a consultant or customer, since we also customize special functions on our standard solutions. We ve been active in the same business area since the company was founded in Our long experience will be a great benefit to our customers. Our systems can be analog, digital and communicating. They control cooling, heating and air, all by requests and needs, and is suitable for most types of applications. Zone ontrols systems also contributes to effective energy saving. Zone ontrols AB is quality certified in accordance with ISO9001 and environmentally certified in accordance with ISO ontact us Do you want to know more about us and our products? Please visit our website - You will find all up-to-date information, news and the latest data sheets available for download. Zone ontrols AB Box 64 S Västerhaninge, SWEDEN Visiting address: Verkstadsvägen 6 S Västerhaninge, SWEDEN Phone: Fax: info@zc.se
Data sheet Thermostatic sensors type RA 2000
Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and district heating
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationControls for fan coil units and cassettes
Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11
More informationTAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
More informationData sheet ECC 12 and 22
Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe
More informationData sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN
More informationsip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationRADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS
RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationFlush-mounted room thermostats
s 3 076 RDF300, RDF300.02, RDF340 RDF400.01 RDF600 RDF600 Flush-mounted room thermostats for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment RDF300
More informationCoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
More informationCommissioning - Construction Documents (Page 1 of 6)
Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem
More informationHVAC and Lighting Control Products for Open Building Automation Systems
HVAC and Lighting Control Products for Open Building Automation Systems Distech Controls offers an extensive line of feature-rich and cost effective controllers for building automation, covering HVAC
More informationT 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ
TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationRadiator valve accessories 1-25-5
TOUR & ANDERSSON HYDRONICS AB Certification of Registration Number 2125 and 2125 M Certified by SP QUALITY AND ENVIRONMENT SYSTEM Radiator valve accessories 1-25-5 2001.04 1 Contents Accessories Presetting
More informationHVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
More informationSensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.
Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual
More informationHeating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
More informationRVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More information3466 Building Energy Management Training Systems
3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available
More informationT5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
More informationCommercial Refrigeration Temperature and Defrost Controls
Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys
More informationABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
More informationBuilding Technologies
Building Technologies RXB room automation system System overview Contents Comfort and well-being in every room...5 Range overview...6 Coordinated room controllers...7 The room units: the key to individual
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
More informationECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions
Instructions *087R9781* *VIKTG202* Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without
More informationThermostatic Actuators
2 111 EN 215-1 RTN51 with remote sensor RTN81 with remote adjuster Thermostatic Actuators for radiator valves VDN, VEN, VUN, VPD and VPE RTN51 RTN81 Self-acting, without auxiliary power High-quality fluid-filled
More informationOn/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range
Electromechanical controls Air control Water control On/off room thermostats range On/off room thermostats range Electronic controls Air control On/off V30 range On/off V30 range Water control Master/slave
More informationRRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationSYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
More informationThe THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT
The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT Presented by: Michael Kuhlmann President Residential Control Systems Inc The Basics Thermostat Functions Measure Room
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationHVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More informationIPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More information225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationHydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
More informationProduct Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationEMO T. Thermal actuator for heating, ventilation and air conditioning systems
EMO T Thermal actuator for heating, ventilation and air conditioning systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEEING ADVANTAGE EMO T Description The EMO T thermal
More informationPlease refer to the chapters below for detailed information about all aspects of the products usage.
EUR_STELLAZ Wall Radiator Thermostat Valve Control Firmware Version : 0.4 Quick Start S This device is a wireless sensor. All operation is performed using the little button behind the round hole in the
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationAdjustable room thermostat for heating only or cooling only systems
3 003 Room hermostat RAA30 Adjustable room thermostat for heating only or cooling only systems Room thermostat with manual O/OFF switch wo-position control witching voltage AC 24 250 V Use he RAA30 room
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationHeating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
More informationDUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.
More informationThermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)
Data Sheet Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity) Application RAS-C² thermostatic sensor RA-FN angle valve The RAS-C² thermostatic sensor is a selfactuating proportional
More informationVroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
More informationManual & Technical Documentation V1.1
Manual & Technical Documentation V1.1 tado Smart Thermostat tado Extension Kit ENGLISH Content Product Packages Compatibility Intelligence & Security Functions Smart Thermostat Usage Menu Structure Special
More informationThermostatic element RAVV for 2-way valves
Description / Application RAVV is a self-acting thermostatic element which can be combined with 2-way valve bodies RAV-/8, VMT-/8 or VMA 15. RAVV is used to control temperatures in small hot water cylinders
More informationThermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
More informationSYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
More informationcontents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
More informationDupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor
Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor Product Description GP6220 330x 724-US is an ultrasonic sensor with a built-in 3 colour LED indicator and part of the Dupline
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationInstall Guide 3M-50. Caution. Caution
PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system.
More informationM9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationPC Software for VAV compact and modular controllers
s 5 854 OpenAir PC Software for VAV compact and modular controllers ACS941 for use with GDB/GLB/ASV181 For Version 3.02 The ACS941 software is used for setting and displaying the parameter values with
More informationHMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationAir damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V
4 613 OpenAir TM Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V GCA12...1 GCA32...1 Electromotive rotary actuators for two-position control, nominal
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationSignature and ISX CM870 Electronics
Signature and ISX CM870 Electronics Cummins West Training Center System Description General Information The Signature and ISX CM870 engine control system is an electronically operated fuel control system
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationTable of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
More informationRF 1. Contents: Connecting diagram. Detailed information:
Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD)
More informationUser Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com
Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1
More information1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
More informationDS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches
DS 1.102 02/99 AIR ROOM TEMPERATURE SENSOR with fan speed control switches Specification No. 528-X-XXX* The Active Room Temperature sensor incorporating fan speed control switches is designed to give a
More informationKNX Lighting Control System
KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting
More informationwww.the Floor Heating Warehouse.co.uk
www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating
More informationActuator for modulating control AME 435
Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design
More informationFailure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
More informationB/S/H/ Error codes and service programmes PH
1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E
More informationT-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
More informationClimate Ready Control Systems Technical Specifications
Climate Ready Control Systems Technical Specifications Climate Ready Control Systems Climate Ready Control Systems consist collectively of motor controllers, other hardware and software packages that will
More informationRKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
More informationTechnical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
More informationPowers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
More informationOPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
More informationWARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:
WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: New Zealand made multi purpose plumbing control for Prison cells Vandal resistant controls Water saving fittings DESCRIPTION Warden 4 is a multi purpose
More informationQuick running actuator
ACTATOR FOR DAMPERS Quick running actuator Actuator with rotation drive. 4 Nm 8 Nm For the application with Laboratory ventilation techniques Room ventilation techniques VAV Valves Page: Content: 3 4-5
More informationAir damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
More informationElectronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
More informationValve range. To be precise.
Valve range To be precise. Thermostatic room temperature control Thermostatic head K with built-in sensor. Graduation cap white RAL 9016, Graduation cap chrome-plated, Graduation cap anthracite grey RAL
More informationyork air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
More information