GPIBShot Taking Screenshots Via IEC/IEEE Bus
|
|
|
- Berenice Gregory
- 9 years ago
- Views:
Transcription
1 Products: FSE, FSIQ, FSP, FSU, FSQ, ZVR, ZVC, ZVA, ZVB, ESIB, ESPI, ESCI, FSMR, FSUP, SMIQ, ABFS GPIBShot Taking Screenshots Via IEC/IEEE Bus GPIBShot is a program for taking and storing screenshots from the Rohde & Schwarz FSx, ESx, ZVx and SMIQ instrument families. Screenshots and trace data can be displayed directly on the PC, stored on the hard disk, or floppy drive and saved to the clipboard. Subject to change M. Weiß MA25_3E
2 Contents 1 Overview Software Features Hardware and Software Requirements... 3 Hardware Requirements... 3 Software Requirements Connecting the Computer and Instrument Installing the Software/Parameter Settings... 3 Presettings and Installation... 3 Instrument Parameters Operating the Software... 4 Getting started... 4 Basic setup... 5 Making hardcopies / Reading trace date... 6 Printing hardcopies / Storing data... 7 Command-Line Operation Additional Information Supported devices Overview GPIBShot is a program for taking and storing screenshots from the Rohde & Schwarz FSx, ESx, ZVx and SMIQ instrument families. Screenshots and trace data can be displayed directly on the PC, stored on the hard disk, or floppy drive and saved to the clipboard. The program supports data exchange with Mircosoft Word and Microsoft Excel. *) For the CMU and CMD instrument families, refer to the corresponding Application Notes (for CMU: 1MA45, for CMD: 1CM30) to copy hardcopies to your PC. 2 Software Features GPIBShot is used for taking screenshots from Rohde & Schwarz instruments via the IEC/IEEE bus. The software offers: GPIB address selection to access the instrument (for instruments supported refer to section 7 Supported devices) The "HARDCOPY" function from the instrument; a screenshot formatted as a WMF file, displayed, and stored: - as a file with date and time - in the clipboard - in Microsoft Word. The "READ TRACE DATA" function from the instrument; numeric trace data, displayed, and stored: - as a file with date and time - in the clipboard - in Microsoft Excel. 1MA25_3E 2 Rohde & Schwarz
3 Printing: the screenshot can be sent directly to a printer. Plotter simulation if the device does not support the hardcopy function (only for R&S approved devices). Run GPIBShot directly from the Microsoft Windows command line to save time, and use GPIBShot with other software as command-line called utility. 3 Hardware and Software Requirements Hardware Requirements The software runs on a PC with the following features: CPU: RAM: Monitor: IEEE bus: 486, Pentium or better 16 Mbyte or more VGA colour monitor Software Requirements IEC/IEEE-bus interface Rohde & Schwarz IEEE bus interface PS-B4, or National Instruments GPIB Microsoft 32-bit operating system (Windows 95 / 98 / NT 4.0 / 2000 / ME) GPIB (IEEE-bus) driver installed 4 Connecting the Computer and Instrument Connect the computer on which GPIBShot is to run to the instruments from which you want to make screenshots. Several instruments can be connected at the same time, such as an FSP Spectrum Analyzer and a ZVR Network Analyzer. Selection is via the instrument s IEC/IEEE-bus address. Make sure that the addresses are unambiguously specified; an address can not be assigned twice. 5 Installing the Software/Parameter Settings Presettings and Installation The Microsoft Installer is used to install GPIBShot. It is not neccessary to install the Microsoft Installer under Windows 2000, or if you have already installed software with the Microsoft Installer. To Install MS lnstaller: under Windows 95 and Windows 98: run InstMSIA. EXE under Windows NT: run InstMSIW.EXE Start SETUP.MSI to install the program. 1MA25_3E 3 Rohde & Schwarz
4 6 Operating the Software During installation, program files are copied to a directory of your choice. An icon is created in your start menu for running GPIBShot. Instrument Parameters Except for the HARDCOPY settings, the program does not modify any parameters on the instrument. You can use any instrument settings with which you wish to create the screenshot. Getting started 1. Start GPIBShot.EXE. If you are using GPIBShot for the first time, the following window will appear: 2. Please follow the instructions on the screen. After clicking "Continue" or entering Name and Key, the user interface will appear: 1MA25_3E 4 Rohde & Schwarz
5 Basic setup Before you can use GPIBShot, you must configure the program to match your setup. The software settings are made in the Setup menu: Choose "Search instruments" to display a list of connected instruments. A box with the search results will pop up. Click the green LED of the instrument you want to use. You can also select the address of the instrument to hardcopy from "Address". If you have previously selected "Search instruments", you see a list of connected instruments with firmware versions. If GPIBShot finds an unknown device, it will be shaded. With the next 2 menu items you select the actions to perform automatically when getting hardcopies or trace data: "Save" saves the hardcopy / trace data to disk (the path is selected via "Path for auto-save files"). "Copy.. to clipboard" copies the hardcopy / trace data to the PC clipboard. "Paste.. in word / excel" pastes the recorder data at the current cursor position in Word / Excel. If numeric data are pasted in Excel, the cursor will move one position right in order to make multiple-data paste-in possible. Use "Path for auto-save files", to select the directory for saving trace data and screen copies. Use "Hardcopy color" to select "b/w" for black-and-white- or "color" for colored hardcopies. All basic setups, such as window position or selected menu items, are saved when GPIBShot is closed and re-loaded at the next startup. 1MA25_3E 5 Rohde & Schwarz
6 Making Hardcopies / Reading Trace Data Run GPIBShot from the Start menu. To create hardcopy of the current screen of the selected instrument, select "Start - Hardcopy". The following operations are performed: A screencopy of the instrument is displayed on your PC screen. If selected, the file "HARDCOPY-<date, time>.wmf" is created in your current selected directory. If selected, graphics are transferred to the clipboard. Use CRTL+V to insert the graphics directly into any other application (eg word processing). If selected, the hardcopy is auto-pasted in word. The right field in the status bar gets dark when the grafic is pasted, and stays gray if no action was done. To create trace data, select "Start - Read trace data". The following operations are performed: The numeric trace data is read from the instrument and displayed on your PC screen. If selected, the file "TRACE-<data, time>.txt" is created in your current selected directory. If selected, trace data is transferred to the clipboard. If selected, the trace-data is auto-pasted in excel. The left field in the status bar gets dark when the grafic is pasted, and stays gray if no action was done. NOTES: If non-active traces are read, the software and/or the analyzer might crash. In this case please restart GPIBShot. The function Read Trace Data assumes a one-to-one X/Y relation. So, trace data such as trellis or eye diagrams cause produce results. The function Read Trace Data does not work with SMIQ. 1MA25_3E 6 Rohde & Schwarz
7 The traces are displayed and stored as shown below: Device Mode Display Saving FSx ESx ZVx analyzer normal trace X-value : Y- value dig. demod., 1D normal trace X- value: Y- value dig. demod., 2D dig. demod., symbol table 1D-display (e.g. phase,...) 2D-display (e.g. smith) vectors with decision points symbols, represented as bits, separated with points as on display as IQ display X- value: I : Q 1 symbol per line, bit-display X- value: Y- value X- value: Y- value *) for some display types such as trellis,..., displaying results is not possible The X-value can be frequency or time, with ZVR also level. Printing hardcopies / Storing data Store or print data from the output menu. "Output Print Hardcopy" outputs the graphics to a printer connected to the computer. The copy fills only 3/4 of the page to leave space for some notes on the printout. A border is added to the picture. "Output Save hardcopy / trace data" opens a standard dialog window to select the path and name of the file to store the hardcopy / trace data. Note By copying graphics from the clipboard, the vector information from the WMF file may be lost, depending on the application you want to paste. You can always use the file stored on your harddisk to get the data in vector graphic (WMF) format. Only the default Windows printer can be used. To switch over to another printer, you have to select this printer as "default printer" in your Windows setup. When making colored hardcopies, the default color settings of the instrument may result in poor output; the marker for example may not be visible. Use B/W or set up the following colors in order to get better results: TRACE: "RED" MARKER: "RED" All other colors can be set to DEFAULT. The stored data in the user directory (trace data and hardcopies) are not deleted automatically. Please delete them when they are no longer used in order to save disk space. 1MA25_3E 7 Rohde & Schwarz
8 7 Additional Information Command-Line Operation To speed up frequently used commands (e.g. taking screenshots only from one instrument), you can pass the command via the command line to GPIBShot. The following commands are available: /{Number between 1 and 31} /COLOR /BW /SCREEN /TRACE{1..4} /HIDE /SHOW /END /NAME=<name> set IEEE address switch to color mode switch to b/w mode take a screen shot read out trace data supress trace display on PC shows window again terminates the program specify the name of the file to generate All combinations ot the commands are possible. The command line is parsed serial. Example: Calling "GPIBSHOT.EXE /HIDE /20 /COLOR /NAME=IMG1 /SCREEN /NAME=DAT1 /TRACE2 /END" takes a colored hardcopy, stored as "IMG1.WMF", and stores the data of trace 2 with the filename "DAT1.TXT" of IEEE device 20 without displaying the graphical user interface. Please contact [email protected] for comments and further suggestions. 1MA25_3E 8 Rohde & Schwarz
9 8 Supported devices EMI Test Receiver ESPI xx all firmware versions ESIB xx Firmware >= 2.02 ESCI xx Spectrum Analyzer FSEx Various firmware >= 1.65 FSP xx all firmware versions FSU xx FSUP xx Phase noise meas. system FSQ xx FSMR xx Signal Analyzer FSIQ x.xx firmware >= 1.9 Vector Network Analyzer ZVx various firmware >= 1.3 Vector Signal Generator SMIQ0x various firmware >= 5.10 Baseband Fading Simulator ABFS ROHDE & SCHWARZ GmbH & Co. KG. Mühldorfstraße 15. D München. P.O.B D München. Telephone Fax Internet: This application note and the supplied programs may only be used subject to the conditions of use set forth in the download area of the Rohde & Schwarz website. 1MA25_3E 9 Rohde & Schwarz
Remote Operation of R&S Instruments Using Remote Desktop Connection via LAN
Products: R&S SMU, R&S SMJ, R&S SMATE, R&S SFU, R&S FSP, R&S FSQ, R&S FSU, R&S FSL, R&S FSUP, R&S FSMR, R&S ESU, R&S ESCI, R&S ESPI, R&S UPV, R&S ZVA, R&S ZVB, R&S ZVT,R&S ZVL Remote Operation of R&S Instruments
Transfer of Trace Data From R&S Network Analyzer ZVx To Microsoft Excel
Products: R&S Network Analyzer ZVA, ZVB, ZVT Transfer of Trace Data From R&S Network Analyzer ZVx To Microsoft Excel Application Note This application note describes how to directly transfer S-Parameter
Remote Monitoring and Control of the R&S FSL with a Web Browser
Rohde & Schwarz Products: R&S FSL3, R&S FSL6, R&S FSL18 Remote Monitoring and Control of the R&S FSL with a Web Browser Application Note This application notes describes remote operation or monitoring
How To Use An Nio V2.2.4.2 (Ios) With A Simioni V2 (V2.3) And V2
Release Notes Revision: 08 R&S ES-SCAN EMI Measurement Software Software Release V2.60 These Release Notes describe the following types and options of the R&S ES-SCAN EMI Measurement Software. R&S ES-SCAN,
PC Software SetupAccelerator: High speed save / restore for 3GPP Signals (for SMIQ option SMIQB48) Products: Vector Signal Generator SMIQ
Products: Vector Signal Generator SMIQ PC Software SetupAccelerator: High speed save / restore for 3GPP Signals (for SMIQ option SMIQB48) This software provides quick save and restore for SMIQ 3GPP/W-CDMA
Remote Monitoring and Control of the R&S FSV with a Web Browser
Rohde & Schwarz Products: R&S FSV3, R&S FSV7, R&S FSV13, R&S FSV30 Remote Monitoring and Control of the R&S FSV with a Web Browser Application Note This application note describes remote operation or monitoring
Using the Equalizer Filter in the VSA Application Firmware for R&S Signal and Spectrum Analyzer Application Note
Using the Equalizer Filter in the VSA Application Firmware for R&S Signal and Spectrum Analyzer Application Note Products: R&S FSQ R&S FSG R&S FMU R&S FSU R&S FSUP R&S FSMR The R&S spectrum analyzers and
Measurements on DVB-S2 Transmitters
Measurements on DVB-S2 Transmitters Application Note Products: R&S FSQ R&S FSG R&S FSU R&S FSUP R&S FSMR R&S FSQ-K70 R&S FSQ-B72 R&S FSU-B73 This application note provides information about measurements
USB Write Protection Utility
Test and Measurement Release Notes USB Write Protection Utility Features: Disables the write capability on any USB Port for USB memory storage devices (Instruments with Windows XP / SP2) Release Note Revision:
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
Firmware Release 4.42 SP2 (XP)
Test and Measurement Division Release Notes (XP) for R&S ESCI Test Receivers with order number: 1166.5950.xx and R&S ESPI Test Receivers with order number: 1164.6407.xx Printed in the Federal Republic
SNMP Example: DVM Management Center Monitoring in a Broadcast Network
Products: R&S DVM50, R&S DVM100, R&S DVM100L, R&S DVM120, R&S DVM400 SNMP Example: DVM Management Center Monitoring in a Broadcast Network Application Note The simple network management protocol (SNMP)
Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note
Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note Products: R&S RTO1012 R&S RTO1014 R&S RTO1022 R&S RTO1024 This application note describes remote operation or monitoring
Software Utility VNA Frequency Converter Leveling Tool Getting Started
Software Utility VNA Frequency Converter Leveling Tool Getting Started (=ONÓ2) Getting Started Test & Measurement 1331.3069.02 01 2016 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany
HTML Code Generator V 1.0 For Simatic IT Modules CP 443-1 IT, 343-1 IT, 243-1 IT
HTML Code Generator V 1.0 For Simatic IT Modules CP 443-1 IT, 343-1 IT, 243-1 IT Manual This manual and program are freeware. Every user can use, copy or forward this program and documentation FREE OF
Manual Software SPECTRO3-MONITORING V5.0
Manual Software SPECTRO3-MONITORING V5.0 (PC software for Microsoft Windows XP, VISTA, 7) for color sensors of the SPECTRO-3 series This manual describes the installation and operation of the SPECTRO3-MONITORING
S7 for Windows S7-300/400
S7 for Windows S7-300/400 A Programming System for the Siemens S7 300 / 400 PLC s IBHsoftec has an efficient and straight-forward programming system for the Simatic S7-300 and ern controller concept can
Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13
Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13 The information contained in this guide is not of a contractual nature and may be subject to change without prior notice. The software described in this
File Management Utility. T u t o r i a l
File Management Utility T u t o r i a l Contents System Requirements... 2 Preparing Files for Transfer to GlobalMark... 2 Application Launch... 2 Printer Setup... 2 Communication Status... 4 Communication
FTP Automation Guide
Products: R&S CRTU-W FTP Automation Guide with WCDMA Protocol Tester R&S CRTU-W Application Note 1CM68 This application note shows how to operate the Automation Manager tool in the R&S CRTU-W to perform
Spectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note
1GA66 Thomas Lechner, 1GPM 19.Aug.2014-0e Spectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note Products: R&S UPV R&S UPV-B2 R&S UPV-K61 R&S UPV-K63 The
User Manual. DG LINK Application Program 071-0056-50. www.tektronix.com. This document applies to firmware version 2.00 and above.
User Manual DG LINK Application Program 071-0056-50 This document applies to firmware version 2.00 and above. www.tektronix.com Copyright Tektronix Japan, Ltd. All rights reserved. Copyright Tektronix,
Brother Automatic E-Mail Printing OPERATION MANUAL
Brother Automatic E-Mail Printing OPERATION MANUAL Copyright Brother 1999 No part of this publication may be reproduced in any form or by any means without permission in writing from the publisher. The
mypro Installation and Handling Manual Version: 7
mypro Installation and Handling Manual Version: 7 Date: JAN 2016 Thank you for using mypro on your PC. myscada is a full featured HMI/SCADA system with advanced options such as vector graphics views, advanced
Xerox DocuPrint P12 Print Driver User Guide
Xerox DocuPrint P12 Print Driver User Guide Xerox Corporation 800 Phillips Road Webster, New York 14580 1998 Xerox Corporation. Xerox, The Document Company, the stylized X, and the identifying product
PRINTER DRIVER GUIDE (KODAK 305 Photo Printer)
PRINTER DRIVER GUIDE () Microsoft, Windows, Windows XP, Windows Vista and Windows 7 are registered trademarks of Microsoft Corporation in the United States and/or other countries. Adobe, Adobe Photoshop
How to Use Rohde & Schwarz Instruments in MATLAB Application Note
How to Use Rohde & Schwarz Instruments in MATLAB Application Note Products: Rohde & Schwarz Instrument Drivers This application note outlines different approaches for remote-controlling Rohde & Schwarz
The serial port is another kind of transmission mode in some outdated PC as a supplementary in failure of USB transmission.
Page 1 of 21 OWON Oscilloscope Installation and Use Guide Welcome to use Oscilloscope analysis software. The kind of communication software is use to acquire, store, analyze and display the data. The instruction
COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS
COMBOGARDPRO 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS IMPLEMENTATION PACKAGE The ComboGard Pro Software implementation package includes: 707012 ComboGard Pro Software Install
DUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
Installation Qualification SWIFT II and SWIFT 1000, version 2.03
Installation Qualification SWIFT II and SWIFT 1000, version 2.03 Introduction and requirements This software operates in the Windows 95, 98, 2000 and NT environments and comprises a number application
Model 288B Charge Plate Graphing Software Operators Guide
Monroe Electronics, Inc. Model 288B Charge Plate Graphing Software Operators Guide P/N 0340175 288BGraph (80207) Software V2.01 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001 585-765-2254
Korosi Monitoring System (KMS) Software Manual
PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval
SOFTWARE INSTALLATION INSTRUCTIONS
AUDITGARD LGA Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS Implementation Package The AuditGard Software implementation package includes: 707013 AuditGard Software Install CD 42145 Programming/Audit
Operating Instructions
Operating Instructions (For Setting up the Printer Driver and the Panasonic Document Management System) Digital Imaging Systems Model No. DP-800P / 800E / 806P Installation Table of Contents Installation
Development Hints and Best Practices for Using Instrument Drivers
Application Note Juergen Engelbrecht 12-Jan-15-1MA153_14e Development Hints and Best Practices for Using Instrument Drivers Application Note Products: Instrument Drivers This document answers frequently
Development Hints and Best Practices for Using Instrument Drivers
Application Note Juergen Engelbrecht 17-Jan-13-1MA153_11e Development Hints and Best Practices for Using Instrument Drivers Application Note Products: Instrument Drivers This document answers frequently
Job Scheduler User Guide IGSS Version 11.0
Job Scheduler User Guide IGSS Version 11.0 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained therein.
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
Twido Simulator - Online Help Scope What's in this Part? Twido Simulator Overview What's in this Chapter? How to Use Twido Simulator
Page 1 of 10 Scope This is the Online Help for the Twido Simulator. The Twido Simulator is a feature of TwidoSuite which allows you to test, run and a debug a program by simulating a connection between
Installing the Gerber P2C Plotter USB Driver
Installing the Gerber P2C Plotter USB Driver 1 You can install a Gerber P2C plotter using a USB connection and communicate with it using compatible design software. The following procedures describe installing
OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES
OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES Thank you for purchasing OFFICE KEYBOARD. This User s manual contains all information that helps you to operate your keyboard. Please keep the software
TestManager Administration Guide
TestManager Administration Guide RedRat Ltd July 2015 For TestManager Version 4.57-1 - Contents 1. Introduction... 3 2. TestManager Setup Overview... 3 3. TestManager Roles... 4 4. Connection to the TestManager
Windows XP Pro: Basics 1
NORTHWEST MISSOURI STATE UNIVERSITY ONLINE USER S GUIDE 2004 Windows XP Pro: Basics 1 Getting on the Northwest Network Getting on the Northwest network is easy with a university-provided PC, which has
Operating Instructions
Operating Instructions (For Setting Up) Digital Imaging Systems Installation Overview Model No. DP-8060 / 8045 / 8035 Table of Contents Setting Your Machine Installation Overview General Installation Overview...
1 DVR 670 Series firmware version 2.1.2 (date 2014-06-17)
Video Recorder 670 Series 1 DVR 670 Series firmware version 2.1.2 (date 2014-06-17) File name: 600rtseries_2.1.2_140617.bin - When a unit detects a HDD error, the DVR will automatically reboot so that
R&S FPS Signal and Spectrum Analyzer Instrument Security Procedures
Signal and Spectrum Analyzer Instrument Security Procedures Resolving security issues when working in secure areas Based upon the user s security requirements, this document describes the Rohde & Schwarz
Manual. PC-Software Save`n carry PP 50 pro
Manual PC-Software Save`n carry PP 50 pro Directory 1 Directory 1 Directory... 2 2 Introduction... 3 2.1 Product description... 3 2.2 Pictograms... 3 2.3 Software installation... 4 2.4 Hardware installation...
Nikon Firmware Update for Coolpix 5000 Version 1.7
Nikon Firmware Update for Coolpix 5000 Version 1.7 Notes: 1. It is most important that you follow the supplied directions; failure to follow all of the steps may result in your camera being disabled. 2.
Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note
Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note Products: R&S FSW This application note introduces the Multi- Standard Radio Analyzer function of the R&S
Instruction manual. testo easyheat Configuration and Analysis software
Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of
Microsoft Word 2010. Quick Reference Guide. Union Institute & University
Microsoft Word 2010 Quick Reference Guide Union Institute & University Contents Using Word Help (F1)... 4 Window Contents:... 4 File tab... 4 Quick Access Toolbar... 5 Backstage View... 5 The Ribbon...
Contents. 1 Overview. R&S FSQ - Instrument Security
Products: R&S Signal Analyzer FSQ Resolving Security Issues When Working with the R&S FSQ in Secure Areas Based upon the user s security requirements, this document describes the Rohde&Schwarz options
R&S FS-K130PC Distortion Analysis Software Specifications
FS-K130PC_dat-sw_en_5214-4113-22_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S FS-K130PC Distortion Analysis Software Specifications 03.03.2014 10:46:15 CONTENTS Specifications... 3 Recommended
Device configurator DRC200
Operating manual 42/49-27 EN Engineer IT Device configurator DRC200 R&C Process Data Management Software Impressum Device configurator DRC200 Operating manual Document No. 42/49-27 EN Date of issue: 11.02
User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR
User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR Content General safety summary...1 Introduction...2 Chapter 1 Getting started...3 System Requirements...4 Installing Hardware...5 Installing Software...8
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
Appendix A. CMS(Client Management Software)
Appendix A. CMS(Client Management Software) A-1. Install CMS for Windows PC CMS is a program for communication between DVR and PC to control signal and video. Insert the enclosed CD, and go to CD-ROM Drive
Backup Server DOC-OEMSPP-S/6-BUS-EN-21062011
Backup Server DOC-OEMSPP-S/6-BUS-EN-21062011 The information contained in this guide is not of a contractual nature and may be subject to change without prior notice. The software described in this guide
ProCod. User Manual. Programming software for TWK - Encoders Series CRF and DAF CRF 11069 DE 08 / 10
Programming software for TWK - Encoders Series CRF and DAF CRF 11069 DE 08 / 10 User Manual ProCod TWK-ELEKTRONIK GmbH D-40041 Düsseldorf PB. 10 50 63 T. 02 11/96117-0 F. 02 11/96117-99 e-mail: [email protected]
Integration of DTV Recorder Generator DVRG into a TCP/IP Network
Product: DVRG Integration of DTV Recorder Generator DVRG into a TCP/IP Network The DTV recorder generator DVRG is a useful tool for recording and replaying MPEG2 transport streams in addition to uncompressed
R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization
FS-K130_bro_en_5214-4113-12.indd 1 Product Brochure 03.00 Test & Measurement R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization 02.10.2014 12:26:18 R&S FS-K130PC Distortion
Advanced Aircraft Analysis 3.6 Network Floating License Installation
Advanced Aircraft Analysis 3.6 Network Floating License Installation 1 Introduction DARcorporation uses the WIBU-Systems WIBU-KEY Copy Protection concept for the AAA network licensing. The WIBU-KEY concept
User s Guide for version 5 Page
Network Management Interface Catalog VPi 32.15E For use with these ATS products: 7000 & 4000 Series (Group 5 Controller) Series 300 (Group 1 Controller), and 940, 962, 436, 434, 447, 448 (Group 6A/7A Control
warpct.com Basic Computer Skills MS Windows XP Workbook courseware by WARP! Computer Training
warpct.com courseware by WARP! Computer Training Basic Computer Skills MS Windows XP Workbook Welcome! Thank you for evaluating a portion of this workbook. If you have any questions or comments regarding
Transfer of Video Stream Files to and from DTV Recorder Generator DVRG
Product: DVRG Transfer of Video Stream Files to and from DTV Recorder Generator DVRG The DTV Recorder Generator DVRG is an inevitable tool for recording and replaying MPEG2 transport streams as well as
Table of Contents. 1. Overview... 3. 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3. 2. Installation Instructions..
Table of Contents 1. Overview..... 3 1.1 Materials Required. 3 1.2 System Requirements. 3 1.3 User Mode 3 2. Installation Instructions.. 4 2.1 Installing the On Call Diabetes Management Software. 4 2.2
GUARD1 PLUS SE Administrator's Manual
GUARD1 PLUS SE Administrator's Manual Version 4.4 30700 Bainbridge Road Solon, Ohio 44139 Phone 216-595-0890 Fax 216-595-0991 [email protected] www.guard1.com i 2010 TimeKeeping Systems, Inc. GUARD1 PLUS
Plotting Spectrum Analyzer Data without a Plotter
Plotting Spectrum Analyzer Data without a Plotter Whitham D. Reeve ( 2013 W. Reeve) 1. Introduction This article describes using a PC to upload and plot measurements from older test sets that do not support
Client applications are available for PC and Mac computers and ios and Android mobile devices. Internet
Introduction to OpenVPN 1 - Introduction to OpenVPN The AN-300-RT-4L2W router features a built-in OpenVPN server for secure, easily configured access to the network from the Internet using devices with
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide
Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide Document Number: P0874391 Document Release: Standard 1.00 Date: November 1997 Year Publish FCC TM 1997 All rights reserved Printed in
DAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
SMS (Server Management Software) Digital Video Recorder. User s Manual
SMS (Server Management Software) Digital Video Recorder User s Manual 1 SMS User s Guide Table of Contents Chapter 1 Overview.....03 1.1 In This Manual..03 1.2 Overview 03 1.3 SMS Features...03 1.4 Product
SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards
SW43W FlukeView Power Quality Analyzer Software Version 3.20 onwards Users Manual 4822 872 30778 December 2005, Rev.1, 04/06 2005 Fluke Corporation, All rights reserved. All product names are trademarks
IGSS. Interactive Graphical SCADA System. Quick Start Guide
IGSS Interactive Graphical SCADA System Quick Start Guide Page 2 of 26 Quick Start Guide Introduction This guide is intended to get you up and running with the IGSS FREE50 license as fast as possible.
Manual. Danfoss Central Station Communications Software Version 3
Manual Danfoss Central Station Communications Software Version 3 RS.8A.Q1.02 1-2001 Contents Introduction 4 System Overview 4 Minimum and Recommended Hardware Requirements 4 Using the Keyboard to Select
TDP-136 TRANSCEIVER DATA PROGRAMMER
TDP-136 TRANSCEIVER DATA PROGRAMMER PC SOFTWARE INSTALLATION & OPERATING INSTRUCTIONS Til Document No. 00RE277 Rev. A (Software V1.1x) NOV 2000 Technisonic Industries Limited 250 Watline Avenue, Mississauga,
R&S ESW EMI Test Receiver Instrument Security Procedures
EMI Test Receiver Instrument Security Procedures (;ÛÍÓ2) 1177.6369.02 01 Test & Measurement Instrument Security Procedures This document is applicable to all R&S ESW models. 2015 Rohde & Schwarz GmbH &
Compressor Supreme Force Feedback User Manual
1. Setting up Compressor Supreme 1. Connect the gear shifter to the back panel of the steering wheel column. 2. Connect the foot pedals to the back panel of the steering wheel column. 3. Connect the A.C.
Microsoft Word 2010 Prepared by Computing Services at the Eastman School of Music July 2010
Microsoft Word 2010 Prepared by Computing Services at the Eastman School of Music July 2010 Contents Microsoft Office Interface... 4 File Ribbon Tab... 5 Microsoft Office Quick Access Toolbar... 6 Appearance
7-1. This chapter explains how to set and use Event Log. 7.1. Overview... 7-2 7.2. Event Log Management... 7-2 7.3. Creating a New Event Log...
7-1 7. Event Log This chapter explains how to set and use Event Log. 7.1. Overview... 7-2 7.2. Event Log Management... 7-2 7.3. Creating a New Event Log... 7-6 7-2 7.1. Overview The following are the basic
Fixplot Instruction Manual. (data plotting program)
Fixplot Instruction Manual (data plotting program) MANUAL VERSION2 2004 1 1. Introduction The Fixplot program is a component program of Eyenal that allows the user to plot eye position data collected with
Excel Tutorial. Bio 150B Excel Tutorial 1
Bio 15B Excel Tutorial 1 Excel Tutorial As part of your laboratory write-ups and reports during this semester you will be required to collect and present data in an appropriate format. To organize and
FreeCapture - A PC remote control program for GDS-800
FreeCapture - A PC remote control program for GDS-800 SERIES (RS-232/GPIB) Version 2.0 Overview Thank you for using GDS-800 SERIES PC remote control program. This program is a demo tool for exploring our
User Manual Version 15.1
Users Manual Version 15.1 Table of Contents 1. Getting Started... 1-1 Ordering Copies of the iq software... 1-1 Installing the iq software... 1-1 Getting Support... 1-1 Contact the iq Help Line......1-1
R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version 2.80.1.2
R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version 2.80.1.2 These Release Notes are for following models of the R&S RTO and R&S RTE: R&S RTO 1012, order no. 1304.6002K12, R&S RTO 1014, order
State of Michigan Data Exchange Gateway. Web-Interface Users Guide 12-07-2009
State of Michigan Data Exchange Gateway Web-Interface Users Guide 12-07-2009 Page 1 of 21 Revision History: Revision # Date Author Change: 1 8-14-2009 Mattingly Original Release 1.1 8-31-2009 MM Pgs 4,
User s Manual for Fingerprint Door Control Software
User s Manual for Fingerprint Door Control Software Foreword The naissance of F7 indicated that fingerprint reader enters into professional door control domain. That s why we developed this software to
GEIGER COUNTER "Gamma Check Pro"
GEIGER COUNTER "Gamma Check Pro" OPERATING INSTRUCTIONS FOR THE SOFTWARE Item no. 1377508 VERSION 11/15 TABLE OF CONTENTS Page 1. Functions of the Software... 3 2. Software/Driver Installation... 3 3.
How to Install and use Windows XP Mode and Windows Virtual PC in Windows 7 for older 32 bit only Applications
How to Install and use Windows XP Mode and Windows Virtual PC in Windows 7 for older 32 bit only Applications Important Applies to Windows 7 Professional, Ultimate, Enterprise As of April 8, 2014, technical
Microsoft Windows Overview Desktop Parts
Microsoft Windows Overview Desktop Parts Icon Shortcut Icon Window Title Bar Menu Bar Program name Scroll Bar File Wallpaper Folder Start Button Quick Launch Task Bar or Start Bar Time/Date function 1
SoundLAB Software Download Software from the Bogen website: www.bogen.com/software
SPLM DIGITAL SOUND PRESSURE LEVEL METER SoundLAB Software INSTALLATION & INSTRUCTION MANUAL Download Software from the Bogen website: www.bogen.com/software Specifications are subject to change without
Xerox 6030/6050/6204 Wide Format BT Plot Assistant User Guide 701P44731
Xerox 6030/6050/6204 Wide Format BT Plot Assistant User Guide 701P44731 Version 1.4 November 2005 Xerox Corporation Global Knowledge & Language Services 800 Phillips Road Bldg. 845-17S Webster, NY 14580
Chapter 3 Software Installation
Software Installation Chapter 3 Software Installation This chapter provides information on how to install the CyberSerial PCI s drivers and utilities for the following operating systems: Windows 95/98
R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement
I/Q Modulation Generator Supplement The following description relates to the Operating Manuals, version 03 of R&S AFQ100A, and version 01 of R&S AFQ100B. It encloses the following topics: LXI features,
Calibration Guide. Agilent Technologies ESG Vector Signal Generator
Calibration Guide Agilent Technologies ESG Vector Signal Generator This guide applies to signal generator models and associated serial number prefixes listed below. Depending on your firmware revision,
PARTNER ACS R4.0 Remote Administration R4.0. Getting Started
PARTNER ACS R.0 Remote Administration R.0 Getting Started 8-6-66 700080 Issue May 00 Copyright 00, Avaya Inc. Document 8-6-66 All Rights Reserved 700080 Printed in USA Issue May 00 Notice Every effort
Scan to PC Desktop: Image Retriever 5.2 for Xerox WorkCentre C2424
Scan to PC Desktop: Image Retriever 5.2 for Xerox WorkCentre C2424 Scan to PC Desktop includes Image Retriever, which is designed to monitor a specified folder on a networked file server or local drive
