1 FS-K130PC_dat-sw_en_ _cover.indd 1 Data Sheet Test & Measurement R&S FS-K130PC Distortion Analysis Software Specifications :46:15

2 CONTENTS Specifications... 3 Recommended system configuration... 3 Distortion Analysis software... 3 Frequency... 3 Level... 3 Bandwidth... 4 Reference signal (Input/ref signal)... 4 Measurement signal (Output/meas signal)... 4 Measurement configuration... 5 Signal processing parameters... 5 Graphical result display... 5 Numerical results... 6 Ordering information... 7 The specifications of the R&S FS-K130PC Distortion analysis software are based on the data sheet specifications of the R&S FSQ/ R&S FSU/R&S FSG/R&S FSV/R&S FSVR/R&S FSUP/R&S FSW signal and spectrum analyzer, have not been checked separately and are not verified during instrument calibration. Measurement uncertainties are given as 95 % confidence intervals. The specified level measurement errors do not take into account systematic errors due to reduced signal to noise ratio (S/N). Specifications apply under the following conditions: 30 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and all internal automatic adjustments performed. Typical values are designated with the abbreviation (typ.). These values are verified during the final test but are not assured by Rohde & Schwarz. Nominal values are design parameters that are not assured by Rohde & Schwarz. These values are verified during product development but are not specifically tested during production. Data without tolerance limits is not binding. 2 Rohde & Schwarz R&S FS-K130PC Distortion Analysis Software

3 Specifications Recommended system configuration Operating system Windows 7 (32-bit or 64-bit) Free hard disk space 1 Gbyte Free RAM 2 Gbyte Graphics resolution UXGA ( pixel) USB 1 free USB port for connecting the smartcard reader (if no PC-built-in smartcard reader is used) License Dongle R&S FSPC (order no ) Measuring instrument connection Hardware: IEC/IEEE bus or LAN connection Software: VISA driver National Instruments VISA Version 5.2 or Agilent IO Libraries Suite 16.2 or later Distortion Analysis software The R&S FS-K130PC distortion analysis software is compatible with R&S FSW signal and spectrum analyzer, R&S FSQ signal analyzer, R&S FSG spectrum analyzer, R&S FSU spectrum analyzer with option R&S FSU-B73, R&S FSV signal and spectrum analyzer, R&S FSVR real-time spectrum analyzer, R&S FSUP signal source analyzer R&S SMU200A, R&S SMJ100A, R&S SMATE200A, R&S SMBV100A, R&S SMW200A vector signal generators. Frequency Frequency range measurement RF input according to the frequency range of the used analyzer and generator as stated in the data sheet Level Level range measurement RF input 50 dbm to +30 dbm 1 Level setting auto 1 1 Restricted IF overload and auto level functionality depending on carrier frequency and bandwidth at carrier frequencies < 50 MHz. Rohde & Schwarz R&S FS-K130PC Distortion Analysis Software 3

4 Bandwidth Sample rate RF input R&S FSW: up to 200 MHz R&S FSQ: 400 Hz to 81.6 MHz R&S FSG: up to 81.6 MHz R&S FSU: up to 81.6 MHz (R&S FSU-B73) R&S FSUP: up to 81.6 MHz R&S FSV: 100 Hz to 45 MHz R&S FSVR: up to 128 MHz with I/Q bandwidth extension R&S FSW: up to 1.2 GHz (R&S FSW-B500) R&S FSQ: up to MHz (R&S FSQ-B72) R&S FSV: up to 400 MHz (R&S FSV-B160) Maximum acquisition bandwidth (equalized) Reference signal (input/ref signal) RF input with I/Q bandwidth extension R&S FSW: 10 MHz R&S FSQ: 28 MHz R&S FSG: 28 MHz R&S FSU: 7 MHz (R&S FSU-B73) R&S FSUP: 7 MHz R&S FSV: 28 MHz R&S FSVR: 40 MHz R&S FSW: 500 MHz (nom.) (R&S FSW-B500) R&S FSQ: 120 MHz (R&S FSQ-B72) R&S FSV: 160 MHz (R&S FSV-B160) Supported numerical signal sources built-in signal types band-limited noise, dual tone, digital modulated band-limited noise selectable bandwidth selectable notch bandwidth crest factor optimization selectable dual tone selectable tone spacing digital modulated selectable modulation type selectable symbol count and oversampling selectable filter type file based file format binary, ASCII, Matlab, IQW, IBN or WV running on ARB any R&S SMx ARB-based standard Reference signal clock rate selectable Reference signal length to samples 2 Reference signal level depending on signal generator Marker control restart marker marker 1/marker 2/marker 3/marker 4 marker timing offset selectable within signal length Signal settling delay 100 ms to 5 s Measurement signal (output/meas signal) Supported measurement signal sources measurement hardware all supported analyzer types file based file format binary, ASCII, Matlab, IQW, IBN or WV simulation (built-in) various simulation modes and parameters Result length to samples Averaging I/Q based averaging 1 to Trigger modes free run, external 2 Tested with 1 Msample reference signal length on a PC with 2 Gbyte memory. 3 Tested with 1 Msample measurement signal; depending on the reference signal length, the averaging factor may be reduced. 4 Rohde & Schwarz R&S FS-K130PC Distortion Analysis Software

5 Measurement configuration DUT port type input port RF output port RF DUT measurement parameters frequency RF frequency multiplier, divider, frequency offset level output RMS level maximum input peak and RMS level post-measurement level can be attenuated or set to RF off DUT input and output attenuation pads fixed attenuation 30 db to 80 db Reference frequency coupling 10 MHz reference frequency source any controlled instrument external reference frequency generator no coupling Signal processing parameters Signal synchronization sync mode none timing, phase and gain full synchronization measurement periods to analyze all/limited to n periods error compensation (individual switchable on or off) I/Q imbalance, I/Q offset, frequency error, timing offset, amplitude droop Generic parameter calculation nonlinear estimation order 5 to 15 Channel estimation active yes or no impulse response taps 64 to 4096 impulse response overlap 5 to 100 % System identification polynomial estimation modes complex, AM and PM polynom estimation degrees full/odd/even fit order min/max degree 1 to 15 System identification spline spline segments 4 to 20 steps per spline 2 to 10 System identification memory polynomial polynomial degree 0 to 15 tap count 0 to 9 System identification volterra Volterra structure configurable up to 9 th order Digital predistortion (DPD) yes/no Graphical result display Results 4 capture buffer ref, meas without and with DPD power (synchronized capture buffer) ref, meas, modeled, ref - meas, modeling error, DPD, expected after DPD, meas after DPD gain gain vs. ref, gain vs. meas, gain vs. ref modeled, EVM vs. ref. gain vs. meas after DPD expected, gain vs. meas after DPD measured constellation ref, meas, modeled, ref meas, DPD, meas after DPD expected and measured AM/AM (amplitude compression) meas, modeled, DPD, meas after DPD expected and measured, reference lines AM/φM (phase compression) meas, modeled, DPD, meas after DPD expected and measured, reference lines I and Q ref I, ref Q, meas I, meas Q, modeled I, modeled Q EVM meas ref, meas model, ref after DPD expected, ref after DPD measured Channel amplitude, phase Rohde & Schwarz R&S FS-K130PC Distortion Analysis Software 5

6 Numerical results Results 4 power measurement DUT input RMS, peak, crest DUT output RMS, peak, crest DUT output leveling error signal synchronization averages executed, confidence frequency offset, phase offset, trigger offset I/Q offset, gain imbalance, quadrature error, I/Q imbalance intercepts gain, compression, 1dB compression point fundamentals, 3 rd and 5 th order product, IP3, IP5 modulation quality EMV RMS, EVM peak system modeling modeling error 4 Depending on the signal processing configuration, some results may not be available. 6 Rohde & Schwarz R&S FS-K130PC Distortion Analysis Software

7 Ordering information Designation Type Order No. Distortion Analysis Software R&S FS-K130PC License Dongle R&S FSPC Signal and Spectrum Analyzer, 2 Hz to 8 GHz R&S FSW Signal and Spectrum Analyzer, 2 Hz to 13.6 GHz R&S FSW Signal and Spectrum Analyzer, 2 Hz to 26.5 GHz R&S FSW Signal and Spectrum Analyzer, 2 Hz to 43.5 GHz R&S FSW Signal and Spectrum Analyzer, 2 Hz to 50 GHz R&S FSW Signal and Spectrum Analyzer, 2 Hz to 67 GHz R&S FSW Signal Analyzer, 20 Hz to 3.6 GHz R&S FSQ Signal Analyzer, 20 Hz to 8 GHz R&S FSQ Signal Analyzer, 20 Hz to 26.5 GHz R&S FSQ Signal Analyzer, 20 Hz to 40 GHz R&S FSQ Signal Analyzer, 9 khz to 8 GHz R&S FSG Signal Analyzer, 9 khz to 13.6 GHz R&S FSG Signal Analyzer, 9 khz to 3.6 GHz R&S FSV Signal Analyzer, 9 khz to 7 GHz R&S FSV Signal Analyzer, 9 khz to 13.6 GHz R&S FSV Signal Analyzer, 9 khz to 30 GHz R&S FSV Signal Analyzer, 9 khz to 40 GHz R&S FSV Real-Time Spectrum Analyzer, 10 Hz to 7 GHz R&S FSVR Real-Time Spectrum Analyzer, 10 Hz to 13.6 GHz R&S FSVR Real-Time Spectrum Analyzer, 10 Hz to 30 GHz R&S FSVR Real-Time Spectrum Analyzer, 10 Hz to 40 GHz R&S FSVR Spectrum Analyzer, 20 Hz to 3.6 GHz R&S FSU Spectrum Analyzer, 20 Hz to 8 GHz R&S FSU Spectrum Analyzer, 20 Hz to 26.5 GHz R&S FSU Spectrum Analyzer, 20 Hz to 43 GHz R&S FSU Spectrum Analyzer, 20 Hz to 46 GHz R&S FSU Spectrum Analyzer, 20 Hz to 50 GHz R&S FSU Signal Source Analyzer, 20 Hz to 8 GHz R&S FSUP Signal Source Analyzer, 20 Hz to 26.5 GHz R&S FSUP Signal Source Analyzer, 20 Hz to 50 GHz R&S FSUP Recommended options and extras I/Q Bandwidth Extension R&S FSQ-B MHz Analysis Bandwidth R&S FSV-B Vector Signal Analyzer (mandatory for R&S FSU) R&S FSU-B See also specifications for the R&S FSW signal and spectrum analyzer (PD ), R&S FSQ signal analyzer (PD ), R&S FSG spectrum analyzer (PD ), R&S FSV spectrum analyzer (PD ), R&S FSVR real-time spectrum analyzer (PD ), R&S FSU spectrum analyzer (PD ) and R&S FSUP signal source analyzer (PD ). Rohde & Schwarz R&S FS-K130PC Distortion Analysis Software 7

8 Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability About Rohde & Schwarz The Rohde & Schwarz electronics group is a leading supplier of solutions in the fields of test and measurement, broadcasting, secure communications, and radiomonitor ing and radiolocation. Founded more than 80 years ago, this independent global company has an extensive sales network and is present in more than 70 countries. The company is headquartered in Munich, Germany. Sustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownership Certified Quality Management ISO 9001 Certified Environmental Management ISO Rohde & Schwarz GmbH & Co. KG R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD Version March 2014 (as) R&S FS-K130PC Distortion Analysis Software Data without tolerance limits is not binding Subject to change Rohde & Schwarz GmbH & Co. KG Munich, Germany PDP 1 en Regional contact Europe, Africa, Middle East customersupport@rohde-schwarz.com North America TEST RSA ( ) customer.support@rsa.rohde-schwarz.com Latin America customersupport.la@rohde-schwarz.com Asia/Pacific customersupport.asia@rohde-schwarz.com China / customersupport.china@rohde-schwarz.com FS-K130PC_dat-sw_en_ _cover.indd :46:16

R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization

R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization FS-K130_bro_en_5214-4113-12.indd 1 Product Brochure 03.00 Test & Measurement R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization 02.10.2014 12:26:18 R&S FS-K130PC Distortion

More information

R&S VSE-K10x R&S FSx-K10x R&S FS-K10xPC EUTRA/LTE Measurement Software Specifications

R&S VSE-K10x R&S FSx-K10x R&S FS-K10xPC EUTRA/LTE Measurement Software Specifications VSE-K100_dat-sw_en_3607-2126-22_cover.indd 1 Data Sheet 01.01 Test & Measurement R&S VSE-K10x R&S FSx-K10x R&S FS-K10xPC EUTRA/LTE Measurement Software Specifications 06.07.2015 17:35:20 CONTENTS Definitions...

More information

AM/FM/ϕM Measurement Demodulator FS-K7

AM/FM/ϕM Measurement Demodulator FS-K7 Data sheet Version 02.00 AM/FM/ϕM Measurement Demodulator FS-K7 July 2005 for the Analyzers FSQ/FSU/FSP and the Test Receivers ESCI/ESPI AM/FM/ϕM demodulator for measuring analog modulation parameters

More information

R&S SMZ Frequency Multiplier Specifications

R&S SMZ Frequency Multiplier Specifications Test & Measurement Data Sheet 02.00 R&S SMZ Frequency Multiplier Specifications CONTENTS Definitions... 3 Specifications... 4 RF performance...4 Frequency...4 Level...4 Spectral purity...4 Connectors...5

More information

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4

More information

Using the Equalizer Filter in the VSA Application Firmware for R&S Signal and Spectrum Analyzer Application Note

Using the Equalizer Filter in the VSA Application Firmware for R&S Signal and Spectrum Analyzer Application Note Using the Equalizer Filter in the VSA Application Firmware for R&S Signal and Spectrum Analyzer Application Note Products: R&S FSQ R&S FSG R&S FMU R&S FSU R&S FSUP R&S FSMR The R&S spectrum analyzers and

More information

R&S ZCxxx Millimeter-Wave Converters Specifications

R&S ZCxxx Millimeter-Wave Converters Specifications ZCxxx_dat-sw_en_3607-1471-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZCxxx Millimeter-Wave Converters Specifications 21.07.2015 15:09:16 CONTENTS Definitions... 3 General information...

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

Measurements on DVB-S2 Transmitters

Measurements on DVB-S2 Transmitters Measurements on DVB-S2 Transmitters Application Note Products: R&S FSQ R&S FSG R&S FSU R&S FSUP R&S FSMR R&S FSQ-K70 R&S FSQ-B72 R&S FSU-B73 This application note provides information about measurements

More information

Realtime FFT processing in Rohde & Schwarz receivers

Realtime FFT processing in Rohde & Schwarz receivers Realtime FFT in Rohde & Schwarz receivers Radiomonitoring & Radiolocation Application Brochure 01.00 Realtime FFT in Rohde & Schwarz receivers Introduction This application brochure describes the sophisticated

More information

Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note

Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note Products: R&S FSW This application note introduces the Multi- Standard Radio Analyzer function of the R&S

More information

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers Making Spectrum Measurements with Rohde & Schwarz Network Analyzers Application Note Products: R&S ZVA R&S ZVB R&S ZVT R&S ZNB This application note describes how to configure a Rohde & Schwarz Network

More information

R&S RNMS3000 Radio Network Management System Utilization planning, radio network configuration and data distribution

R&S RNMS3000 Radio Network Management System Utilization planning, radio network configuration and data distribution RNMS3000_bro_en_5213-9640-12_v0200.indd 1 Product Brochure 02.00 Secure Communications R&S RNMS3000 Radio Network Management System Utilization planning, radio network configuration and data distribution

More information

R&S ZVA Vector Network Analyzer Specifications

R&S ZVA Vector Network Analyzer Specifications www.atecorp.com 8-44-ATEC (2832) R&S ZVA Vector Network Analyzer Specifications ZVA_dat-sw_en_523-568-22_v_cover.indd Data Sheet. E stablished 98 Advanced Test Equipment Rentals Test & Measurement 4.5.22

More information

Vector Signal Analyzer FSQ-K70

Vector Signal Analyzer FSQ-K70 Product brochure Version 02.00 Vector Signal Analyzer FSQ-K70 July 2004 Universal demodulation, analysis and documentation of digital radio signals For all major mobile radio communication standards: GSM

More information

Rohde & Schwarz Service that adds value

Rohde & Schwarz Service that adds value Rohde & Schwarz Service that adds value Rohde & Schwarz Extended Warranty We want to help you control your costs. And that s why we freeze them for years. The Extended Warranty offers cost control while

More information

R&S AVG050 DVB Satellite Receiver Compact DVB-S and DVB-S2 satellite demodulator

R&S AVG050 DVB Satellite Receiver Compact DVB-S and DVB-S2 satellite demodulator AVG050-SAT_bro_en_3606-8508-12_v0200.indd 1 Product Brochure 02.00 Broadcast & Media R&S AVG050 DVB Satellite Receiver Compact DVB-S and DVB-S2 satellite 08.09.2015 13:23:25 R&S AVG050 DVB Satellite Receiver

More information

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line

More information

R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks Broadcasting Product Brochure 01.00 R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage

More information

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6

More information

R&S RCMS II Remote Control & Monitoring System For ATC and air defense applications

R&S RCMS II Remote Control & Monitoring System For ATC and air defense applications RCMSII_bro_en_5213-6464-12.indd 1 Product Brochure 09.00 Secure Communications Remote Control & Monitoring System For ATC and air defense applications 26.05.2014 13:12:01 Remote Control & Monitoring System

More information

R&S MKS9680 Modular Encryption Device Secure voice, fax and data transmission

R&S MKS9680 Modular Encryption Device Secure voice, fax and data transmission Secure Communications Product Brochure 01.01 R&S MKS9680 Modular Encryption Device Secure voice, fax and data transmission R&S MKS9680 Modular Encryption Device At a glance The R&S MKS9680 is a highly

More information

Using R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products:

Using R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products: Application Note, P. Diestelhorst, P. Geltinger 8.2013-1MA215_3e Using R&S NRP-Z Power Sensors with Android TM Handheld Devices Products: Application Note R&S NRP-Z This application note describes how

More information

R&S IP-GATE IP gateway for ISDN encryption devices

R&S IP-GATE IP gateway for ISDN encryption devices Secure Communications Product Brochure 0.00 R&S IP-GATE IP gateway for ISDN encryption devices R&S IP-GATE At a glance The R&S IP-GATE is an IP interface for the most recent models of the R&S MKS9680 and

More information

R&S Analysis Center Automatic radio network detection and situation picture visualization

R&S Analysis Center Automatic radio network detection and situation picture visualization Radiomonitoring & Radiolocation Data Sheet 01.00 R&S Analysis Center Automatic radio network detection and situation picture visualization R&S Analysis Center At a glance R&S Analysis Center was developed

More information

R&S IP-GATE IP gateway for R&S MKS9680 encryption devices

R&S IP-GATE IP gateway for R&S MKS9680 encryption devices Secure Communications Product Brochure 0.00 R&S IP-GATE IP gateway for encryption devices R&S IP-GATE At a glance The R&S IP-GATE is an IP interface for the encryption device. Used with the, the R&S IP-GATE

More information

Production testing of radar sensors for automotive applications

Production testing of radar sensors for automotive applications Production testing of radar sensors for automotive applications Innovative, cost-efficient solution for component and functional test Test & Measurement Application Brochure 01.00 Production testing of

More information

R&S RTO Digital Oscilloscope Resolving Security Issues When Working in Secure Areas

R&S RTO Digital Oscilloscope Resolving Security Issues When Working in Secure Areas Digital Oscilloscope Resolving Security Issues When Working in Secure Areas Based upon the user s security requirements, this document describes the Rohde&Schwarz options available to address the user

More information

How To Use An Nio V2.2.4.2 (Ios) With A Simioni V2 (V2.3) And V2

How To Use An Nio V2.2.4.2 (Ios) With A Simioni V2 (V2.3) And V2 Release Notes Revision: 08 R&S ES-SCAN EMI Measurement Software Software Release V2.60 These Release Notes describe the following types and options of the R&S ES-SCAN EMI Measurement Software. R&S ES-SCAN,

More information

Spectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note

Spectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note 1GA66 Thomas Lechner, 1GPM 19.Aug.2014-0e Spectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note Products: R&S UPV R&S UPV-B2 R&S UPV-K61 R&S UPV-K63 The

More information

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper Products: R&S RTO1012 R&S RTO1014 R&S RTO1022 R&S RTO1024 This technical paper provides an introduction to the signal

More information

Basic Tests of NFC Enabled Devices Using R&S Test Equipment

Basic Tests of NFC Enabled Devices Using R&S Test Equipment Application Note Roland Minihold/Rainer Wagner 2.2015 1MA190_5e Basic Tests of NFC Enabled Devices Using R&S Test Equipment Application Note Products: ı R&S SMBV100A ı R&S FSL ı R&S SMBV-K89 ı R&S FSV

More information

R&S ZNC Vector Network Analyzer Solid performance on a future-oriented platform

R&S ZNC Vector Network Analyzer Solid performance on a future-oriented platform Test & Measurement Product Brochure 01.00 R&S ZNC Vector Network Analyzer Solid performance on a future-oriented platform R&S ZNC Vector Network Analyzer At a glance High reliability, outstanding ease

More information

R&S RA CHM System Status Monitoring For maximum system availability

R&S RA CHM System Status Monitoring For maximum system availability A-CHM_bro_en_3607-0975-12_v0300.indd 1 Product Brochure 03.00 adiomonitoring & adiolocation &S A CHM System Status Monitoring For maximum system availability 09.07.2015 10:52:38 &S A CHM System Status

More information

R&S ZVL Vector Network Analyzer Specifications

R&S ZVL Vector Network Analyzer Specifications R&S ZVL Vector Network Analyzer Specifications Test & Measurement Data Sheet 08.02 CONTENTS Specifications... 3 Measurement range... 3 Measurement speed... 3 Measurement accuracy... 4 Effective system

More information

R&S BC NETSTATE Open network management software for broadcast applications

R&S BC NETSTATE Open network management software for broadcast applications R&S BC NETSTATE Open network management software for broadcast applications Broadcasting Product Brochure 01.00 R&S BC-NETSTATE At a glance R&S BC NETSTATE is a specialized software solution for broadcast

More information

R&S UMS170 Compact Radiomonitoring System High performance for outdoor deployment

R&S UMS170 Compact Radiomonitoring System High performance for outdoor deployment UMS170_bro_en_5214-5810-12.indd 1 Product Brochure 02.00 Radiomonitoring & Radiolocation R&S UMS170 Compact Radiomonitoring System High performance for outdoor deployment 08.07.2014 12:55:00 R&S UMS170

More information

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards Broadcasting Product Brochure 04.00 R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards R&S SLx8000 Family of UHF/VHF Transmitters At a glance The

More information

Agilent E6832A W-CDMA Calibration Application

Agilent E6832A W-CDMA Calibration Application Agilent E6832A W-CDMA Calibration Application For the E6601A Wireless Communications Test Set Data Sheet The next generation of mobile phone manufacturing test. E6601A is the newest test set from Agilent

More information

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas EFL240_340_bro_en_5214-6000-12_v0400.indd 1 Product Brochure 04.00 Broadcasting R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

More information

R&S SMZ Frequency Multiplier Precise output levels from 50 GHz to 170 GHz

R&S SMZ Frequency Multiplier Precise output levels from 50 GHz to 170 GHz SMZ_bro_en_5214-4336-12_v0200.indd 1 Product Brochure 02.00 Test & Measurement R&S SMZ Frequency Multiplier Precise output levels from 50 GHz to 170 GHz 24.09.2013 09:46:58 R&S SMZ Frequency Multiplier

More information

R&S ESL EMI Test Receiver Compact, cost-effective measuring receiver

R&S ESL EMI Test Receiver Compact, cost-effective measuring receiver R&S ESL EMI Test Receiver Compact, cost-effective measuring receiver Test & Measurement Product Brochure 01.00 R&S ESL EMI Test Receiver At a glance The R&S ESL EMI test receiver combines two instruments

More information

LTE System Specifications and their Impact on RF & Base Band Circuits. Application Note. Products: R&S FSW R&S SMU R&S SFU R&S FSV R&S SMJ R&S FSUP

LTE System Specifications and their Impact on RF & Base Band Circuits. Application Note. Products: R&S FSW R&S SMU R&S SFU R&S FSV R&S SMJ R&S FSUP Application Note Dr. Oliver Werther/Roland Minihold 04.2013 1MA221_1E LTE System Specifications and their Impact on RF & Base Band Circuits Application Note Products: R&S FSW R&S SMU R&S SFU R&S FSV R&S

More information

WLAN Protocol Tester PTW 70

WLAN Protocol Tester PTW 70 Data sheet Version 01.00 WLAN Protocol Tester PTW 70 November 2003 IEEE 802.11 multimode protocol tester for development, integration and verification Applications Development The PTW 70 is an indispensable

More information

R&S VISA Release Notes Software Version 5.5.4

R&S VISA Release Notes Software Version 5.5.4 R&S VISA Release Notes Software Version 5.5.4 2015 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

Broadcast Drive Test Software

Broadcast Drive Test Software Broadcasting Release Notes Broadcast Drive Test Software Release Notes Version 03.12 2013 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance

More information

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface R&S UMS12 Monitoring System Modular monitoring system with open programming interface Radiomonitoring & Radiolocation Data Sheet 01.00 R&S UMS12 Monitoring System At a glance The R&S UMS12 is a new member

More information

Apple ipad Remote Control for Broadcasting T&M Instruments Application Note

Apple ipad Remote Control for Broadcasting T&M Instruments Application Note Apple ipad Remote Control for Broadcasting T&M Instruments Marius Schipper 10.2012-7BM82_1E Apple ipad Remote Control for Broadcasting T&M Instruments Application Note Products: R&S DVMS1 / DVMS4 R&S DVSG

More information

Lip-Sync Measurement (AV Delay) for TV Displays Application Note

Lip-Sync Measurement (AV Delay) for TV Displays Application Note Lip-Sync Measurement (AV Delay) for TV Displays Application Note Products: R&S DVSG Hameg HMO3524 This application note describes the measurement of AV delay on TVs and monitors. Determining the delay

More information

R&S ZVB Vector Network Analyzer High measurement speed up to 20 GHz with two or four test ports

R&S ZVB Vector Network Analyzer High measurement speed up to 20 GHz with two or four test ports Test & Measurement Product Brochure 07.00 R&S ZVB Vector Network Analyzer High measurement speed up to 20 GHz with two or four test ports R&S ZVB Vector Network Analyzer At a glance Built using innovative

More information

R&S SITGate Next-Generation Firewall Secure access to Internet and cloud services

R&S SITGate Next-Generation Firewall Secure access to Internet and cloud services Secure Communications Product Brochure 02.00 R&S SITGate Next-Generation Firewall Secure access to Internet and cloud services R&S SITGate Next-Generation Firewall At a glance The R&S SITGate is a multifunctional,

More information

Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note

Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note Remote Monitoring and Control of the R&S RTO with a Web Browser Application Note Products: R&S RTO1012 R&S RTO1014 R&S RTO1022 R&S RTO1024 This application note describes remote operation or monitoring

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Fast and Accurate Test of Mobile Phone Boards

Fast and Accurate Test of Mobile Phone Boards Products: R&S FSP Fast and Accurate Test of Mobile Phone Boards Short test times in conjunction with accurate and repeatable measurement results are essential when testing and calibrating mobile phones

More information

R&S TS-EMF EMF Measurement System Easy, frequency- selective measurement of EMF emissions

R&S TS-EMF EMF Measurement System Easy, frequency- selective measurement of EMF emissions Test & Measurement Data Sheet 03.00 R&S TS-EMF EMF Measurement System Easy, frequency- selective measurement of EMF emissions R&S TS-EMF EMF Measurement System At a glance In combination with Rohde & Schwarz

More information

PXI. www.aeroflex.com. GSM/EDGE Measurement Suite

PXI. www.aeroflex.com. GSM/EDGE Measurement Suite PXI GSM/EDGE Measurement Suite The GSM/EDGE measurement suite is a collection of software tools for use with Aeroflex PXI 3000 Series RF modular instruments for characterising the performance of GSM/HSCSD/GPRS

More information

RF Measurements Using a Modular Digitizer

RF Measurements Using a Modular Digitizer RF Measurements Using a Modular Digitizer Modern modular digitizers, like the Spectrum M4i series PCIe digitizers, offer greater bandwidth and higher resolution at any given bandwidth than ever before.

More information

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP Department of Electrical and Computer Engineering Ben-Gurion University of the Negev LAB 1 - Introduction to USRP - 1-1 Introduction In this lab you will use software reconfigurable RF hardware from National

More information

EE 186 LAB 2 FALL 2004. Network Analyzer Fundamentals and Two Tone Linearity

EE 186 LAB 2 FALL 2004. Network Analyzer Fundamentals and Two Tone Linearity Network Analyzer Fundamentals and Two Tone Linearity Name: Name: Name: Objective: To become familiar with the basic operation of a network analyzer To use the network analyzer to characterize the in-band

More information

R&S RA-CM Continuous Monitoring Software Status monitoring of complex COMINT systems

R&S RA-CM Continuous Monitoring Software Status monitoring of complex COMINT systems Radiomonitoring & Radiolocation Product Brochure 01.01 R&S RA-CM Continuous Monitoring Software Status monitoring of complex COMINT systems R&S RA-CM Continuous Monitoring Software At a glance The R&S

More information

Automotive Ethernet Compliance Testing

Automotive Ethernet Compliance Testing Automotive Ethernet Compliance Testing Dr. Ernst Flemming Product Manager Rohde & Schwarz GmbH & Co. KG Munich, Germany The company group at a glance ı History Established 1933 in Munich, Germany ı Type

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:

More information

VoIP Measurements for WiMAX Application Note

VoIP Measurements for WiMAX Application Note VoIP Measurements for WiMAX Application Note Products: R&S CMW270 R&S UPV R&S UPV-K1 R&S UPV-K4 R&S UPV-K61 R&S UPV-K9 R&S UPV-K91 This application note describes the necessary steps and configuration

More information

Field Calibration Software

Field Calibration Software SIGNAL HOUND Field Calibration Software User s Manual Version 1.1.0 7/8/2016 This information is being released into the public domain in accordance with the Export Administration Regulations 15 CFR 734

More information

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help

More information

and Measurement Software

and Measurement Software R&S TS8997 and Measurement Software Quick Calibration Guide 1520.9633.62 1 E-2 COPYRIGHT Copyright 2013 Rohde & Schwarz GmbH & Co KG. All rights reserved. Portions of the software described in this document

More information

R&S CMWrun Sequencer Software Tool Applications

R&S CMWrun Sequencer Software Tool Applications Sequencer Software Tool Applications CMWrun_app-bro_en_3606-8243-91_v0200.indd 1 Sequencer Software Tool Test & Measurement Application Brochure 02.00 Ready-to-use solution for configuring test sequences

More information

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz The new R&S FSW 43 and R&S FSW 50 signal and spectrum analyzers make the outstanding features of the R&S FSW family available now also

More information

Firmware Release 4.42 SP2 (XP)

Firmware Release 4.42 SP2 (XP) Test and Measurement Division Release Notes (XP) for R&S ESCI Test Receivers with order number: 1166.5950.xx and R&S ESPI Test Receivers with order number: 1164.6407.xx Printed in the Federal Republic

More information

Software Utility VNA Frequency Converter Leveling Tool Getting Started

Software Utility VNA Frequency Converter Leveling Tool Getting Started Software Utility VNA Frequency Converter Leveling Tool Getting Started (=ONÓ2) Getting Started Test & Measurement 1331.3069.02 01 2016 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany

More information

How to Use Rohde & Schwarz Instruments in MATLAB Application Note

How to Use Rohde & Schwarz Instruments in MATLAB Application Note How to Use Rohde & Schwarz Instruments in MATLAB Application Note Products: Rohde & Schwarz Instrument Drivers This application note outlines different approaches for remote-controlling Rohde & Schwarz

More information

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox Application Note Introduction Of all the signal engines in the N7509A, the most complex is the multi-tone engine. This application

More information

Network analyzer and spectrum analyzer two in one

Network analyzer and spectrum analyzer two in one R&S ZVL Vector Network Analyzer Network analyzer and spectrum analyzer two in one The R&S ZVL is the lightest and smallest vector network analyzer in its class. On top of this, it can be used as a full-featured

More information

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment RF and Microwave Accessories CD-ROM Catalog Find the right component for your Rohde & Schwarz test & measurement equipment Product group Typical applications Adapters Interchanging of various connector

More information

MATRIX TECHNICAL NOTES

MATRIX TECHNICAL NOTES 200 WOOD AVENUE, MIDDLESEX, NJ 08846 PHONE (732) 469-9510 FAX (732) 469-0418 MATRIX TECHNICAL NOTES MTN-107 TEST SETUP FOR THE MEASUREMENT OF X-MOD, CTB, AND CSO USING A MEAN SQUARE CIRCUIT AS A DETECTOR

More information

Conquering Noise for Accurate RF and Microwave Signal Measurements. Presented by: Ernie Jackson

Conquering Noise for Accurate RF and Microwave Signal Measurements. Presented by: Ernie Jackson Conquering Noise for Accurate RF and Microwave Signal Measurements Presented by: Ernie Jackson The Noise Presentation Review of Basics, Some Advanced & Newer Approaches Noise in Signal Measurements-Summary

More information

R&S ZNB Vector Network Analyzer Leading in speed, dynamic range and ease of operation

R&S ZNB Vector Network Analyzer Leading in speed, dynamic range and ease of operation ZNB_bro_en_5214-5384-12_v0601.indd 1 Product Brochure 06.01 Test & Measurement R&S ZNB Vector Network Analyzer Leading in speed, dynamic range and ease of operation 02.09.2015 10:56:56 R&S ZNB Vector Network

More information

Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH

Building a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 office@gtec.at, http://www.gtec.at Building a Simulink model for real-time

More information

A Guide to Calibrating Your Spectrum Analyzer

A Guide to Calibrating Your Spectrum Analyzer A Guide to Calibrating Your Application Note Introduction As a technician or engineer who works with electronics, you rely on your spectrum analyzer to verify that the devices you design, manufacture,

More information

How To Use A Sound Card With A Subsonic Sound Card

How To Use A Sound Card With A Subsonic Sound Card !"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+

More information

R&S FPS-K10 GSM Measurement User Manual

R&S FPS-K10 GSM Measurement User Manual R&S FPS-K10 GSM Measurement User Manual (;ÚâÞ2) User Manual Test & Measurement 1176.8480.02 06 This manual applies to the following R&S FPS models with firmware version 1.30 and higher: R&S FPS4 (1319.2008K04)

More information

GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy

GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy Introduction A key transmitter measurement for GSM and EDGE is the Output RF Spectrum, or ORFS. The basis of this measurement

More information

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview Reduce your cost of ownership by minimizing time to calibrate and

More information

Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP

Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP Products: Spectrum Analyzer FSP Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP This application note explains the concept of Adjacent Channel Leakage Ratio (ACLR) measurement

More information

R&S FSW-K10 GSM Measurement User Manual

R&S FSW-K10 GSM Measurement User Manual R&S FSW-K10 GSM Measurement User Manual (; êí2) User Manual Test & Measurement 1173.9263.02 08 This manual applies to the following R&S FSW models with firmware version 2.00 and higher: R&S FSW8 (1312.8000K08)

More information

One Port Network Analyzer

One Port Network Analyzer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com One Port Network Analyzer 5.4GHz Impendance : 50Ω(75Ωconnectors via adapters) Test

More information

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer

APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is

More information

R&S NRPV Virtual Power Meter Release Notes Application Version 1.8.0

R&S NRPV Virtual Power Meter Release Notes Application Version 1.8.0 R&S NRPV Virtual Power Meter Release Notes Application Version 1.8.0 2011-2015 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Subject to change Data without tolerance limits is not binding. R&S is

More information

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

Performing Amplifier Measurements with the Vector Network Analyzer ZVB Product: Vector Network Analyzer R&S ZVB Performing Amplifier Measurements with the Vector Network Analyzer ZVB Application Note This document describes typical measurements that are required to be made

More information

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range Application Note Table of Contents 3 3 3 4 4 4 5 6 7 7 7 7 9 10 10 11 11 12 12 13 13 14 15 1. Introduction What is dynamic range?

More information

OTA performance measurements of MIMO-enabled devices

OTA performance measurements of MIMO-enabled devices OTA performance measurements of MIMO-enabled devices Cost-effective solution with 3D evaluation and easy-to-use test setup Test & Measurement Application Brochure 01.00 OTA performance measurements of

More information

ELCRODAT 5-4 Highly secure voice and data communications in digital and analog networks

ELCRODAT 5-4 Highly secure voice and data communications in digital and analog networks Highly secure voice and data communications in digital and analog networks Secure Communications Data Sheet 02.02 At a glance The (ED5-4) is used by military organizations and government authorities for

More information

R&S FSVA/FSV Signal and Spectrum Analyzer Instrument Security Procedures

R&S FSVA/FSV Signal and Spectrum Analyzer Instrument Security Procedures Signal and Spectrum Analyzer Instrument Security Procedures Resolving security issues when working in secure areas Based upon the user s security requirements, this document describes the Rohde & Schwarz

More information

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Application Note RF & Microwave Spectrum Analyzers Table of Contents 3 3 4 4 5 7 8 8 13 13 14 16 16 Introduction Absolute versus relative

More information

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer Application Note Introduction The RF power amplifier is a key component used in a wide variety of industries such as wireless

More information

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Technical Brief Introduction The MSO70000 Series Mixed Oscilloscope, when coupled with SignalVu Spectrum

More information

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity

More information

NI USB-5681 RF Power Meter Specifications

NI USB-5681 RF Power Meter Specifications NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour

More information

RF Level Measurement Uncertainties with the Measuring Receiver R&S FSMR

RF Level Measurement Uncertainties with the Measuring Receiver R&S FSMR Products: R&S FSMR, R&S NRP-Z27/37, R&S NRP-Z51/55 RF Level Measurement Uncertainties with the Measuring Receiver R&S FSMR Application Note Measurement uncertainties that occur when the R&S FSMR measuring

More information

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps Wideband USB Synthesized Signal Generator 50Ω -60 dbm to +10 dbm, 25-6000 MHz The Big Deal Wideband generator with 3 Hz frequency resolution 70dB adjustable output power range Internal pulse modulation

More information