Methodology for Accurate Mass Measurement of Small Molecules
|
|
|
- Camilla Harmon
- 10 years ago
- Views:
Transcription
1 Methodology for Accurate Mass Measurement of Small Molecules Best Practice Guide Co-ordinating Editors *Ken Webb, *Tony Bristow, *Mike Sargent and # Bridget Stein *LGC Limited, Teddington, UK # EPSRC National Mass Spectrometry Centre, Swansea, UK
2 ISBN LGC Limited 2004 Published by LGC Limited
3 Methodology for Accurate Mass Measurement of Small Molecules Best Practice Guide November 2004 VIMMS/2004/01 Coordinating Editors: Ken Webb*, Tony Bristow*, Mike Sargent* and Bridget Stein # * LGC Limited, Teddington, UK # EPSRC National Mass Spectrometry Centre, Swansea, UK
4 Preface This Guide was prepared as part of the Department of Trade and Industry s VIMMS Programme, an initiative which formed part of the UK National Measurement System. The Guide was prepared by LGC in collaboration with members of a specially formed Working Group whose assistance is gratefully acknowledged. The members of the Working Group during the course of the work are listed below. In the past the phrase accurate mass was interpreted very broadly and covered a wide variety of mass spectrometry measurements, with varying precision. Today, most instruments used for accurate mass measurements are capable of achieving precisions of 10 ppm or better. This Guide is concerned with application to small to medium size molecules and resulted from a review 1 of accurate mass applications which was undertaken as part of the VIMMS Programme. The review 1 highlighted the recent rapid growth in the use of mass spectrometry for molecular weight determinations of small to medium sized molecules, particularly in the chemical and biochemical industries. This growth has been fuelled by a number of factors, including the rapid pace of instrument development, enabling accurate mass and molecular weight measurements to be made in a more robust and less costly fashion. A number of experts have expressed concern that this rapid growth has resulted in unreliable data being obtained by operators who often have little experience of AccMass applications or even of mass spectrometry. Discussion of the issues by experts at a forum meeting highlighted the need to prepare guidance on undertaking key aspects of the methodology in order to obtain robust measurements and traceable data. It was emphasised, however, that preparation of such guidance should be supported by an experimental evaluation of the methodology, including the implications of variations between type of spectrometer. Consequently, an interlaboratory comparison 2 was organised by LGC as part of the VIMMS programme to evaluate variations in accurate mass measurements and to improve understanding of the key experimental factors in obtaining reliable data from each type of mass spectrometer. The lessons learned from this study have played a major role in shaping the advice offered in the Guide. The main aim of this document is to provide users and suppliers of AccMass instrumentation with a clear summary of the essential steps in obtaining reliable data. In addition, the reader should obtain a better understanding of the limitations of different types of spectrometer and the particular precautions which are necessary in setting up the instruments and making measurements. We hope that the Guide will also facilitate an understanding of the principles of the technique and prove useful for both private study and training courses. A glossary of the terms used in this Guide has been included to assist in its use for training purposes. Mike Sargent VIMMS Programme Manager LGC November 2004 Page i
5 Acknowledgement The work described in this Guide was supported under contract with the Department of Trade and Industry. Page ii
6 Members of the VIMMS Working Group Professor Gareth Brenton University of Wales Swansea Dr Tony Bristow LGC Dr Malcolm Clench Sheffield Hallam University Dr Alex Colburn University of Warwick Dr Paul Gates University of Cambridge Mr Brian Green Micromass Dr Chris Harbach M-Scan Dr Mark Harrison Thermo Electron Dr Neville Haskins Consultant Dr Jackie Jarvis Bruker Daltonics Professor Keith Jennings Consultant Dr John Langley University of Southampton Dr Pat Langridge-Smith University of Edinburgh Dr Bill Leavens GlaxoSmithKline Dr Steve Lock Applied Biosystems Mrs Helen Lomax Applied Biosystems Dr Gwyn Lord University of London Professor Tony Mallet University of Greenwich Dr Peter Marshall GlaxoSmithKline Dr George McLeod Syngenta Professor John Monaghan University of Edinburgh Dr Mike Morris Micromass Mr George Perkins Pfizer Dr Ian Sanders Bruker Daltonics Dr Mike Sargent LGC Mr Russell Scammell Argenta Discovery Dr Jim Startin Central Science Laboratory Ms Bridget Stein EPSRC National Mass Spectrometry Centre Mr Peter Watkins Thermo Finnigan Dr Ken Webb LGC Dr John Wilkins Consultant Dr Jean-Claude Wolff GlaxoSmithKline Page iii
7 Contents Preface i 1. Introduction 1 2. Background General Issues Instrumentation 3 3. Best Practice Tuning and Peak Shape Ion Abundance Resolving Power Calibration External Calibration Internal Calibration Sample Introduction Data Manipulation Validation and Quality Control Checks Selection of Elemental Formulae Use of Accuracy, Precision or Uncertainty Data The Nitrogen Rule Rings Plus Double Bonds (R + DB) Isotope Information NMR and other spectroscopic methods Instrument Specific Guidance Magnetic Sector Peak Matching Dynamic Voltage Scanning Magnet Scanning Fourier-Transform Ion Cyclotron Resonance Single Quadrupole and Triple Quadrupole Time-of-Flight (TOF) and Quadrupole-TOF 15 5 References 17 Glossary of Terms 19 Glossary References 23 Bibliography 24 Appendix 1: Journal Requirements for Accurate Mass Data Used for Formula Confirmation 29 Page iv
8 1. Introduction Accurate mass measurement of small molecules is used to determine elemental formulae. The better the accuracy the less the ambiguity 3. In general, the interpretation of an accurate mass measurement carried out at a resolution of 10,000 (10% valley definition) is non-ambiguous up to 300 daltons (Da) when only including C, H, N and O due to the low number of potential elemental formulae. With increasing mass to charge ratio (m/z) the number of possible formulae dramatically increases making identification more and more difficult 4. The increasing variety of instrumentation together with the increasing numbers of new entrants into the field of mass spectrometry has created an urgent need for clear and informative guidance. FTMS currently offers the highest mass resolution of any mass spectrometer 5, exceeding that of the traditional high resolution magnetic sector instruments. Though not usually considered as tools for accurate mass measurement, lower resolution quadrupole, triple quadrupole, quadrupole ion trap and TOF mass spectrometers have also been applied to such measurements. Accuracy of measurement using quadrupole ion trap instruments varies with the mass and the type of ion and is generally no better than 50 ppm. Hence ion trap instruments have not been included in this guidance document. In order to produce guidance based on sound experimental knowledge, a study to evaluate a wide range of accurate mass measurement techniques was undertaken 1. This study has enabled the editors to collate experience of the various accurate mass measurement techniques in a single document and to provide comprehensive advice on best practice for accurate mass measurement. This was followed with an inter-laboratory comparison involving a large number of expert users and was co-ordinated by LGC in It should be noted that instrumentation is always developing and mass measurement accuracy is constantly improving; this is particularly true of TOF instruments. The inter-laboratory comparison data relates only to the instrument capabilities in The results of the inter-laboratory comparison, which involved the accurate mass measurement of a compound of molecular weight 475 with no interfering ions present, have recently been published 2. Irrespective of instrument type and the experience of the user, the instrument must be calibrated over an appropriate mass range incorporating the mass of interest by using a suitable reference material. This primary calibration should be established where possible with traceable or authenticated materials and confirmed from time to time by measuring a reference material. A glossary of the terms used in this guide and a bibliography have been included to assist in the use of this document for training purposes. 2. Background 2.1 General Issues An accurate and precise mass measurement increases the certainty of identification of an elemental formula. If accuracy and precision (i.e. the measurement uncertainty) are known, these values can be used to reduce the number of candidate molecular formulae to be considered. For example, if the mass measurement accuracy of 5 ppm (±2 ppm precision) is routinely achieved, mass measurements to within 7 ppm should be considered in the initial data Page 1
9 evaluation, rather than the top 10 or 20 hits from the results table, which is the more usual approach. This is particularly important for determining the elemental formula of a complete unknown. Each type of analyser will have unique parameters that will contribute to the overall uncertainty of the accurate mass measurement. Very little work has been carried out on this subject but some initial work has been described 6,7. Although not fully described here, guidance to the general concept and principles of measurement uncertainty is available 8. It is important to understand the degree of accuracy required relative to the m/z of the ion that is measured. Setting fixed acceptable error limits for exact molecular mass measurement is not recommended 4. With increasing m/z the number of formulae which will fit a measured molecular mass increases until an unambiguous result becomes impossible to obtain and this is illustrated in Figure Number of Formulae (C,H,N,O) Da 600 Da 1000 Da Mass Accuracy (ppm) Figure 1: The effect of mass accuracy and molecular weight on the number of potential elemental formulae (source: Quenzer, T. L. et al. 9 ). It is also important to distinguish between the integer mass of the nominal mass ion, the calculated exact mass and the average mass. Table 1 below illustrates the different numerical values resulting from these definitions 10 for several molecules. Page 2
10 Table 1: The distinction between common definitions of molecular mass (uncharged species) Formula Molecular Mass (See Glossary for definition of terms) Nominal Exact Average Sulphamethazine C 12 H 14 N 4 O 2 S Ketaconazole C 26 H 28 Cl 2 N 4 O Ubiquitin C 378 H 630 N 105 O 118 S Sulphamethazine has an average mass of , a nominal mass of 278 and a calculated exact monoisotopic mass of Ketaconazole contains two chlorine atoms; the nominal mass ion contains two 35 Cl atoms whereas the mass of the average mass ion is calculated using the natural abundance ratio of the 35 Cl and 37 Cl atoms. At much higher masses the effect of the different definitions can be considerable. Ubiquitin, a protein with a formula C 378 H 630 N 105 O 118 S, has an average mass of , a nominal mass of 8556 and a calculated exact monoisotopic mass of Note that the presence of several hydrogen atoms increases the exact monoisotopic mass above an integral value and when more than some 130 hydrogen atoms are present the exact mass is one or more units higher than the nominal mass. This is because the 1 H isotope has an exact mass of Da. The 630 hydrogen atoms in Ubiquitin have a combined exact monoisotopic mass of , which very significantly increases the calculated exact mass value over the nominal mass (630). Factors such as temperature, humidity, vibration and local magnetic fields can affect instrumental stability and hence reproducibility of results. It is important to ensure that the temperature is both within the manufacturers specification range and is also stable; this is of particular importance for TOF instruments. A varying temperature will cause an external calibration to drift producing poor mass measurement accuracy. There may be a lesser, but still significant, effect on internal calibration. High humidity can produce condensation on electrical components and high voltage arcing, causing instrument damage. Hence it is advisable to install air conditioning for all accurate mass work. Vibration will arise from lorries, trains, tram lines and lifts. The floor on which the instrument is situated should also be considered, the higher the floor number the worse is the potential for vibration problems. Local magnetic fields such as those caused by other magnet scanning instruments or large machinery such as lifts nearby are important. 2.2 Instrumentation Magnetic sector instruments offer high mass resolution (up to 150,000 (10% valley, see Section 3.3)) and have traditionally been used for many years for accurate mass measurement. FTMS instruments are capable of very high resolution (up to 1,000,000 (FWHM)), but have only started to become popular during the last few years. Lower resolution instruments such as TOF, quadrupole-tof and triple quadrupoles have not been traditionally employed to record accurate mass measurements. However, recent advances in instrument design have made this possible to some extent. Such instruments are compact, generally bench-top, relatively easy to use, rugged and may not require purpose-built accommodation. The cost and ease of use of the different types of instruments vary widely and should be taken into consideration when selecting an instrument. There are a number of different ion sources used to generate ions for Page 3
11 accurate mass measurement. In general the choice of ion source has no significant effect on mass measurement accuracy; however, it is generally accepted that the accuracy using FAB or MALDI can be lower than with the use of other sources, possibly due to matrix effects. The inter-laboratory comparison co-ordinated by LGC 2 showed that in many cases an identical protocol and mass spectrometer were used by several participants to make the mass measurements, but an equivalent performance was not reported. This illustrates the need for guidance on the appropriate application of the various protocols employed. The overall observations from the inter-laboratory comparison are summarised below. In the inter-laboratory comparison the high accuracy achievable when using magnetic sector instruments was readily demonstrated. The results showed that for the three common mass measurement techniques reported when using such instruments, peak matching and dynamic voltage scanning clearly produced the most accurate results, with 88% and 60% of mean mass measurements 1 ppm, respectively. Only 50% of the laboratories that employed dynamic magnet scanning experiments reported data with mean mass accuracy of 10 ppm. The results clearly reflect the accepted capability of the three techniques. Further details of the peak matching, dynamic voltage scanning and the dynamic magnet scanning experiments can be found in Section 4.1. Using FTMS, 83% of the results reported showed mean mass measurement accuracy of 1 ppm. This result is comparable with that from peak matching and superior to that recorded using dynamic voltage scanning on magnetic sector instruments and meets the expectation of the capability of FTMS for accurate mass measurements. For the lower resolution instruments, quadrupole-tof spectrometers produced the highest accuracy measurements, with 83% of results within 5 ppm compared with 65% from conventional TOF instruments. This may be due as much to the optimisation of current protocols as to any deficiency in instrument capability. ESI data was obtained from either orthogonal-tof or orthogonal quadrupole-tof instruments. MALDI data was obtained from either axial-tof or orthogonal quadrupole-tof instruments. The orthogonal-tof data showed accuracies with the majority within 10 ppm, whilst the axial-tof data showed accuracies within 25 ppm (see also Figure 4). The capabilities of TOF and quadrupole-tof mass spectrometers have only recently been enhanced to allow accurate mass measurements to be recorded. Only two triple quadrupole instruments were used in the inter-comparison and these produced mean mass measurement accuracy of < 2 ppm. These results illustrate the capability of lower resolution mass spectrometers when a sound experimental protocol is used and there are no unresolved isobaric ions. The way in which the measurement is carried out is critical in achieving high accuracy. 3. Best Practice In order to achieve high accuracy and good precision a number of key considerations must be understood and optimised where applicable. 1 Tuning and peak shape 2 Ion abundance Page 4
12 3 Resolving power 4 Calibration 5 Sample introduction 6 Data manipulation 7 Validation and Quality Control checks 8 Selection of elemental formulae These considerations are considered in turn in the following sections. 3.1 Tuning and Peak Shape As accurate mass measurements are generally carried out with the mass spectrometer operating in peak profile (continuum) mode, the centre of the peak (centroid) on the m/z scale must be accurately assigned. An accurate measurement can only be obtained if there is a homogeneous (mono-isotopic) peak that is symmetrical (an exception here are TOF peaks, which are not symmetrical). Regardless of the type of mass spectrometer employed to record accurate mass measurements, poorly defined peaks will result in mass measurement error and poor precision. The peak shape can be affected by poor instrument tuning, low ion counts, unresolved interferences, mechanical vibration and electronic ripple. Tune the instrument carefully this should include optimising ionisation conditions, which increases ion counts, and optimising ion transmission from source to analyser and detector which influences peak shape. Consider the use of chromatographic separation techniques to remove unresolved interferences where possible. The effect of poor peak shape on mass accuracy when using FTMS is illustrated in Figure Ion Abundance Ion abundance is important in the determination of accurate mass both in terms of being too high or too low. For high intensity signals there is a danger of saturating the detector. The mass measurement of a low intensity signal can result in poor mass accuracy because of poor peak shape and poor ion statistics, which means the centroid is not accurately defined on the m/z scale. The mass measurement accuracy of the TOF or quadrupole-tof mass spectrometer is impaired with high ion counts due to time-to-digital converter (TDC) dead time, a characteristic of the detectors used in these instruments. This is the time after each ion is recorded when the TDC is not able to record another ion count. The mass accuracy of the FTMS can be affected by space charge effects; the best mass accuracy with FTMS is achieved when the total number of ions in the analyte experiment is equal to the total number of ions used in calibration 11. If either phenomenon is encountered a reduction in ion count should be achieved by reducing analyte concentrations or the amount of analyte introduced (injection volume). When using magnetic sector instruments the three techniques (peak matching, dynamic voltage scanning and dynamic magnet scanning) used for accurate mass measurement are not adversely affected by ions at high abundance unless detector saturation is reached. Low abundance ions can be detrimental to mass accuracy as they may lead to poor peak shape and inaccurate peak centroids. Page 5
13 Intens. x \ESI_Tune_small: +MS x \ESI_Tune_small: +MS m/z Figure 2: The effect of FTMS peak shape on mass accuracy, top = 2.5 ppm, bottom = 0.5 ppm Ion abundance is also important when calibration is carried out. See Section Page 6
14 3.3 Resolving Power Two definitions are used routinely, depending on the type of instrument employed to make the mass measurement. 10% valley (intensity) definition: this is useful only for instruments giving triangular-shaped peaks (e.g. magnetic sector instrument peaks). Two peaks of equal intensity are considered to be resolved when they are separated by a valley which is 10% of the height of each peak (made up from a 5% contribution from each component) (Figure 3.) In practice, by this definition a resolution of 1000 means that m/z 1000 and m/z 1001 have a 10% valley between them. m can be measured from the separation of the two peaks or from the width of a single peak at the 5% height ( m is the difference between m and the value of the next highest m/z value ion that can be separated from m, in m/z units). This definition has been traditionally used with magnetic sector instruments. Figure 3: The definitions of resolving power (source: courtesy of Professor Tony Mallett) 50% valley (intensity) definition (full width half maximum, FWHM): the quadrupole, FTMS, ion trap and TOF definition is based on a peak width measured at 50% peak height, producing a value approximately double that calculated using the 10% valley definition (comparison only valid for instruments giving gaussian-shaped peaks (e.g. magnetic sector instrument peaks). The resolving power required for an accurate mass measurement is determined by the measurement problem (factors here include the m/z values to be resolved, the presence of background interferences) and therefore this determines the instrument that can be used. Increasing the resolving power of the mass spectrometer narrows the peak widths. The result of this is that data systems can centroid the peaks more accurately, reducing the error of mass measurement and decreasing the ambiguity. However, increasing the resolving power decreases the signal strength on some analysers (for example, magnetic sector) and this can affect the precision of measurement. In these cases a balance must be achieved and it is advised that the resolving power used should not exceed that required to resolve background interferences or other m/z values that may need to be resolved. This will limit the selection of Page 7
15 the instrument. For an accurate mass measurement it is essential that interferences are resolved. 3.4 Calibration Calibration of the m/z scale of the mass spectrometer is achieved using a reference compound yielding ions of known m/z. Appropriate instrument calibration is vital for good mass measurement accuracy. Calibration should cover the complete range of analyte masses; extrapolation of the calibration range will not give good results. Mass calibration is one of the most critical parameters to consider in the achievement of accuracy. If the calibration is poor then even a high precision mass measurement will be poor in terms of accuracy. Two calibration protocols are used with accurate mass measurement, as described in the following sections. External calibration is generally necessary; the additional use of an internal calibrant can substantially improve accuracy and is necessary on certain instruments. There are some important considerations that apply to both external and internal calibration: Ensure that the reference compound has many reference ions, particularly in the region of the ions to be accurately mass measured Ensure that the ions are of a similar nature where possible; for example, the calibrant ion and analyte ions should be in the same charge state External Calibration In this case calibration is carried out prior to analysis. The spectrum of a known reference compound is recorded and the peaks in the spectrum are assigned to their exact masses by the instrument data system to produce the correct calibration. Clearly a good external calibration is required to obtain good mass accuracy, particularly when an internal calibrant (reference mass ion) is not used for subsequent accurate mass measurements. It should be noted that external calibration only works satisfactorily if the instrument is sufficiently stable. Tips for achieving a good external calibration: Carry out the calibration as close in time as possible to the accurate mass measurement to minimise effects of instrument drift Maintain temperature control of the instrument environment to minimise drift. There are many compounds employed as external calibrants for mass spectrometry and their selection is determined by the ionisation technique to be employed and the working m/z range. Details of many are supplied by the instrument manufacturers in the literature provided with the instruments, but a list, though not exhaustive of many of the common calibrants and those used in the inter-laboratory comparison, is shown in Table 2. Page 8
16 Table 2: List of common calibrants Chemical Name m/z Range Uses Sodium iodide + Caesium iodide mixture ES (+ and -) FAB/LSIMS (+ and -) Perfluorokerosene (PFK) EI (+) and CI (+ and -) Perfluorotributylamine (PFTBA) EI (+) and CI (+ and -) Polyethylene glycol mixture /(PEG ) ES (+) and APCI (+) Peptide mixtures ca ES (+) Horse heart myoglobin ES (+) Horse radish peroxidase ES (+) Ultramark F-series EI/CI Internal Calibration This is generally required for all instruments except FTMS for which external calibration can achieve sufficient accuracy. With internal calibration the m/z scale is calibrated using a single ion or a series of ions of known m/z from a reference compound that is introduced into the mass spectrometer ion source at the same time as the analyte. This method is superior to external calibration since the effects of instrumental drift are removed, and should be used whenever possible unless ions from the reference compound interfere with the analyte ions. The use of a single or double point internal calibration is sometimes referred to as lock mass. Usually the use of two calibrant ions to bracket the analyte ion will achieve better accuracy. To achieve optimum mass accuracy the m/z of a single point calibrant ion should be as close as possible to that of the analyte ion; this is particularly important for magnetic sector mass spectrometers. The abundance of the internal calibrant ion or ions can have a profound effect on mass accuracy 12,13,14. For best accuracy these ions should be of the same abundance as the analyte ions. Ion abundance and peak shape are major contributors to the mass accuracy achieved using internal calibrant ions regardless of instrument type. 3.5 Sample Introduction Where a constant ion abundance for the analyte and reference ion can be maintained (e.g. via a gas inlet, syringe pump and in some instances a direct insertion probe), particularly in a range that provides optimum performance, the accuracy of the mass measurement will be improved 14. It is important to consider whether the ion signal generated by the analyte compound is transient or constant. In the use of chromatography, MALDI and in some instances the direct insertion probe, where a transient signal is generated, the abundance of the analyte ion at the point of measurement needs careful consideration. The point on the transient signal where the measurement is taken can be adjusted to optimise the ion abundance. If ion abundance is too high the detector may be saturated, if too low there Page 9
17 may not be sufficient ions for an accurate measurement. When the transient signal is of high intensity the measurement should be taken near the tail of the peak (the end) to avoid saturating the detector. Where it is of low intensity the measurement should be taken across the top of the peak so as to maximise the number of ions used for measurement. It is suggested that where possible, say, five scans are taken and the results averaged. Too high or too low abundance problems of an internal calibrant ion can be avoided by maintaining the abundance at a constant optimum level. The calibrant can be introduced into the ion source at a constant rate or known background interferences can be used as reference points. The width of a transient signal is relevant to the scan speed of the mass spectrometer. The residence time of the transient signal must be taken into account when selecting the scan speed. For fast (narrow width) transient signals the scan speed must be sufficiently fast so as to record at least five scans of satisfactory intensity across the signal. This is particularly significant when using capillary gas chromatography columns and sector field instruments in magnet scanning mode. Multiple measurements should be carried out on the unknown to establish the precision of measurement. This is especially true for hyphenated systems when scans across a transient signal may need to be inspected individually to select scans where the signal intensities for the reference and unknown are roughly equal. 3.6 Data Manipulation There are a number of ways in which the final mass measurement can be determined and a list of appropriate possible elemental formulae generated. For many mass spectrometers, the calculation of the measured mass and generation of a list of elemental formulae are completely automated within the instrument data system. But it should be noted that the post acquisition software parameters can have an effect on the final result and within the software a number of parameters may be manipulated to obtain the final measurement. For example, the points on a peak used to define the centroid and the peak smoothing can both be adjusted and will have an effect on the final mass measurement. Many data systems employ a series of common procedures including those listed below. Record spectrum in profile mode Baseline subtract raw data (to remove interferences on or near peak of interest) Select centroiding conditions and centroid ion of interest Adjust external calibration using internal calibration Specify conditions for elemental composition calculator (possible elements, precision, charge state, type of ion [M+H] +, M +., [M+Na] + etc) Produce a list of potential elemental formulae based on the measured accurate mass It should be noted that with some data systems centroiding and internal calibrant correction are automated processes within the experiment and cannot be modified by user input. When using a peak matching unit to record accurate mass measurements with a magnetic sector mass spectrometer the above processing steps are not necessary and the instrument readout reflects the measured mass. For older instruments the last two steps are carried out manually. One additional point to consider is the parameters used to calculate an elemental formula. Not all data systems take into account the mass of an electron ( Da) when calculating the Page 10
18 formula from the specified ion, which can introduce an error at very high accuracy (an error of 5.5 ppm at m/z 100). To avoid this systematic error both the analyte and calibrant ions should take into account the mass of an electron or both should ignore it. 3.7 Validation and Quality Control Checks The reliability of the automated data manipulation process should be checked by using as an analyte a compound of known accurate mass as a quality control (QC) sample to ensure correct data system operation. It is also important to treat the analyte, QC sample and calibrant in the same manner from a data processing point of view. The QC check should also be used to give an indication of the uncertainty of measurement. The uncertainty information from a QC check should be used to reduce the number of candidate molecular formulae to be considered. See also Section 2.1. In terms of calibration the analyte should be mass measured relative to a suitable internal reference compound wherever possible. This can be used to adjust any drift in the primary calibration. It is important that the intensity of the signal from the reference and the unknown are roughly equal. At least one reference ion of known mass should be used to verify the accuracy of the primary calibration. If it is not possible to use an internal reference then an external calibration should be carried out immediately before the analyte is measured. 3.8 Selection of Elemental Formulae Accurate mass measurement is used to determine the elemental formulae of molecule and fragment ions for confirming the presence of known compounds or to assist in identification of an unknown compound. In order to be able to assign elemental formulae and structures there are a number of key strategies that should be employed and these are described below Use of Accuracy, Precision or Uncertainty Data This type of information, obtained from a QC check should be used to reduce the number of candidate molecular formulae to be considered. See also Section The Nitrogen Rule Nitrogen has an even atomic mass (14) but is trivalent. Thus any small molecule containing common elements and an odd number of nitrogen atoms will have an odd numbered molecular weight. If the molecule ion is an even number it must have an even number of or zero nitrogen atoms Rings Plus Double Bonds (R + DB) From valency considerations the total number of rings and double bonds in a molecule of formula C a H b N c O d is equal to: R + DB = a - ½b + ½c + 1 Where other elements are present, these are counted as additional atoms of C, H, N or O to which they correspond in valency. For example, the number of silicon atoms should be added to the number of carbon atoms, the number of halogen atoms to the number of hydrogen atoms Page 11
19 and the number of phosphorous atoms to the number of nitrogen atoms. It should be noted that this is based on the lowest valence state of the elements, and does not count double bonds formed to atoms in higher valence states. For an elemental formula to be theoretically possible R + DB must be greater than 1.5. Moreover, if the ion is odd electron (M + ) the R + DB value will be an integer and conversely, a non-integer R + DB value indicates an even-electron ion. So, if the ion type is known, formulae giving an inappropriate R + DB value can be discarded Isotope Information A number of elements have distinctive isotope patterns and if these elements are contained in the analyte of interest then that distinctive pattern can be recognised. Careful scrutiny of the isotope pattern of the ions measured may also allow you to narrow down the number of possibilities. Chlorine has a distinctive isotope pattern (relative abundance of the naturally occurring isotopes 35 Cl: 37 Cl is in the ratio 3:1), making the presence of chlorine in the sample fairly obvious (e.g. add chlorine to the list of possible elements if the isotope pattern indicates it is present). Likewise the ratios for multiple chlorine atoms can be calculated and recognised if present. Other common elements having distinctive isotope patterns include bromine ( 79 Br: 81 Br 1:1)and sulphur ( 32 S: 33 S: 34 S 100:1:4). Observation of the 12 C/ 13 C ratio can give the number of carbon atoms in the analyte. Naturally occurring carbon contains approximately 1.1% of the 13 C isotope. As a result of this an ion containing 10 carbon atoms will have a 13 C isotope peak with an abundance ~11% of the 12 C peak. Similarly an ion containing 50 carbon atoms will have a 13 C isotope peak with an abundance ~55% of the 12 C peak. Hence a simple 12 C/ 13 C ratio measurement will give a good indication of the number of carbon atoms present within the precision of the mass spectrometer NMR and other spectroscopic methods Once an empirical formula has been assigned to an unknown it is often possible to elucidate its structure by combining data from the mass measurement of fragment ions and from other techniques such as NMR spectroscopy and infra-red spectroscopy. A simple example is now presented to illustrate the selection of elemental formulae 10. Suppose a molecule ion is determined to have a mass value of Table 3 gives the accurate m/z values for a variety of ion compositions, but which is the most likely elemental composition? Application of the nitrogen rule and R + DB rule eliminate all given formulae except numbers 3, 4, 5, 8 and 11 (even number of N atoms because it has an even molecular mass and integer R + DB because it is a radical cation (odd electron ion)). Of these formulae only C 3 H 6 O is within 200 ppm of the measured mass and is thus the most likely formula. See also Appendix 1 for journal requirements on the use of accurate mass measurement for elemental formulae determination. Page 12
20 Table 3: All possible elemental compositions corresponding to mass value of with element limits C - 4, H - 10, N - 4, O - 2 and mass precision limits of ± 1000 ppm Fomula Number Elemental Composition Calculated Mass Deviation ppm R + DB C H N O Instrument Specific Guidance The following guidance reflects experience from the LGC inter-laboratory comparison 2 and the views of the expert consultation panel. The number of instruments used for each type of spectrometer in the inter-laboratory comparison is shown in Table 4. Table 4: Instrument types used in the LGC inter-laboratory comparison 2 Instrument Type Number Used in Inter-laboratory Comparison Magnetic sector 21 FTMS 8 Single quadrupole 0 Triple quadrupole 2 TOF (axial and orthogonal) 16 Quadrupole-TOF (orthogonal) 10 Page 13
21 4.1 Magnetic Sector There are a number of different ways in which accurate mass measurement can be carried out using this type of analyser. These are peak matching, dynamic voltage scanning and magnet scanning Peak Matching To record an accurate mass measurement using the peak matching technique, a lock (reference) mass (M R ) is introduced at the same time as the analyte 13,14,15. With constant magnetic field, the accelerating voltage is adjusted so that M R and the analyte ion (M U ) are observed to be coincident. The ratio of the two voltages is inversely proportional to the masses so M U can be calculated. This process can be carried out using a manual peak matching unit and oscilloscope or via the instrument data system and computer monitor. This method can produce very accurate results, readily to within 1 ppm of the true value. This was observed in the inter-laboratory comparison where 88% of mean mass measurements were 1 ppm. For best accuracy the reference mass should be as close as possible to the analyte mass (at the same nominal mass is optimum), providing both masses are well resolved Dynamic Voltage Scanning In the dynamic voltage scanning technique (known as V/E scan or accelerating voltage (V) scan) a very narrow mass range (V varied by up to 10%) is scanned by varying the accelerating voltage 16 while the magnetic field is held constant. Initially, the magnet is positioned (or parked) at the starting m/z value just below the mass range of interest. The accelerating voltage (V) is then scanned to permit the m/z range of interest and at least two bridging reference ions to pass through the instrument. The electric sector (formerly known as electrostatic analyser, E) is scanned simultaneously to prevent deterioration in resolution due to kinetic energy spread. Usually a narrow range internal calibration is used to make the measurements. When using EI, between 1 and 3 ions from PFK or PFTBA (or other appropriate calibrant) are selected. In the inter-laboratory comparison the m/z range for internal calibration was no greater than ±56 Th from the analyte ion. A number of laboratories employed FAB for the inter-laboratory comparison and selected two ions from poly(ethyleneglycol) 600 that bracketed the analyte ion. The inter-laboratory comparison demonstrated that mass accuracy within 5 ppm could readily be achieved by > 90% of participants using dynamic voltage scanning with 60% of participants reporting mean mass measurement accuracy of 1 ppm Magnet Scanning In this technique the magnetic sector is scanned over a wide m/z range whilst keeping the accelerating voltage constant. The advantage of this method is that all of the ions in the spectrum of interest can be mass measured. Whilst not as accurate as peak matching or dynamic voltage scanning it can provide good quality data provided care is taken. The interlaboratory comparison showed that the best accuracy that could be achieved was 3 ppm 2, but the variation in the reported mean mass accuracy was significantly greater (3 ppm 42 ppm) than that observed for both peak matching and voltage scanning. In practice the magnet scan Page 14
22 should be started well above (say 100 Th) the highest mass ion of interest to ensure a smooth and reproducible magnet scan at the masses of interest. The inter-scan time should be sufficient to allow the magnetic field to stabilise before commencing the next scan. The reference compound should be of sufficient concentration to ensure that no reference ions are missed. Best accuracy is achieved using internal calibration; however, if the reference compound is not present when the analyte is run, the use of a single point calibrant (lock mass) is recommended. The magnet scan speed should not be too rapid, 10 sec/decade for directly introduced compounds that can remain resident within the ion source. Where a chromatographic inlet is used a balance must be achieved between scan speed and analyte peak width and scan speeds as fast as 0.1 sec/decade may have to be used, although this will compromise accuracy. 4.2 Fourier-Transform Ion Cyclotron Resonance FTMS currently offers the highest mass resolution of any mass spectrometer 5. FTMS is routinely used for accurate mass measurement with mass resolution in excess of 1x10 6 and mass accuracy of 1 ppm 17. This was clearly demonstrated in the inter-laboratory comparison 2. For small molecule accurate mass measurement an external calibration is initially carried out covering the mass range of interest. Before measuring the analyte ion, the external calibration should be checked using the calibration compound, and all calibrant ions should ideally be within 1 ppm of their theoretical values. The mass measurement of the analyte ion is then carried out using the external calibration. Further improvement in mass accuracy ( 0.5 ppm) can be achieved using internal calibration. An important parameter to consider when recording accurate mass measurements using FTMS is the relative abundance of the external calibrant and analyte ions. Care should be taken to ensure that they are similar 11 and within the range where space charge effects will not occur. 4.3 Single Quadrupole and Triple Quadrupole These are inherently low resolution instruments that have not been routinely used to record accurate mass measurements. However, accurate mass measurements (<5 ppm) can be obtained from them provided due care is taken, particularly with the calibration procedure, and when no unresolved interferences are present at the masses of interest 18. This was emphasised in the inter-laboratory comparison as both laboratories that recorded their measurements using triple quadrupole instruments reported mean mass measurement accuracy of < 2ppm 2. Both laboratories employed an internal calibration protocol using multiple ions (a minimum of 5) in the range ± m/z 74 from the analyte ion. A high sampling rate of 128 points per Th was used. 4.4 Time-of-Flight (TOF) and Quadrupole-TOF TOF and quadrupole-tofs are inherently low resolution instruments. With current technology the resolutions (FWHM) achievable by TOF and quadrupole-tof instruments are up to about The inter-laboratory comparison showed that accuracies of better than 5 ppm can be achieved provided some care is taken (see Figure 4 for data on orthogonal and axial TOF instruments). Quadrupole-TOF instruments produced the higher accuracy measurements, with 83% 5 ppm, compared with 65% from TOF instruments. Ideally, external calibration should be carried out just before the mass measurement. In the inter-laboratory comparison, the majority of laboratories that reported data using either a quadrupole-tof or TOF instrument employed a lock (reference) mass. In the inter-laboratory comparison some laboratories used a lock mass ion that was as much as 258 m/z units away from the analyte ion. However, such a Page 15
23 large difference in m/z did not adversely effect the mass accuracy, a mean mass measurement accuracy of < 1 ppm was achieved in this case. The key parameter to consider when using a lock mass with TOF and quadrupole-tof instruments is the relative and absolute abundance of the analyte and lock (reference) ions. This factor is particularly important with chromatographic introduction and it is recommended that a measurement be taken in the tail of an eluting component peak within a specified range of ion abundance. As ion abundance increase rapidly in the leading edge of an eluting peak, it is more difficult to select the optimum measurement point Orthogonal acceleration TOFs Axial TOFs 30 Error (ppm) Laboratories Figure 4: Mass measurement error of orthogonal and axial TOF instruments in interlaboratory comparison Page 16
24 5 References 1) Sargent, M. and O Connor, G., Feasibility study: Mass spectrometry techniques for accurate molecular weight determinations of large molecules. Reference number LGC/VAM/2001/026. Available from the author upon request. 2) Bristow, A. W. T. and Webb, K. S., Intercomparison study on accurate mass measurements of small molecules in mass spectrometry. J. Am. Soc. Mass. Spectrom., 14, (2003). 3) Gross, M. L., Accurate masses for structure confirmation. J. Am. Soc. Mass. Spectrom., 5, 57 (1994). 4) Price, P. C., Gale, P. J., Loo, J. A, Heller, D. N, Richardson, S. D. and Duncan, M. W., ASMS guidelines for exact mass measurement and elemental composition new perspectives. Proceedings of the 50 th Annual Conference on Mass Spectrometry and Allied Topics, Orlando FL, (2002). 5) Marshall, A.G., Scaling MS plateaus with high-resolution FT-ICRMS. Anal. Chem., 74, 253A-259A (2002). 6) Sack, T. M., Lapp, R. L., Gross, M. L. and Kimble, B. J., A method for the statistical evaluation of accurate mass measurement quality. Int. J. Mass Spectrom. Ion Processes.,61, (1984). 7) Blom, K. F., Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer. Anal Chem.,73, (2001). 8) Quantifying Uncertainty in Analytical Measurements. EURACHEM guide, LGC, Teddington (2000). 9) Quenzer, T. L., Robinson, J. M., Bolanios, B., Milgram, E. and Greig, M. J., Automated accurate mass analysis using FTICR mass spectrometry. Proceedings of the 50 th Annual Conference on Mass Spectrometry and Allied Topics, Orlando FL, (2002). 10) Personal Communication, Professor Tony Mallet. 11) Taylor, P. K. and Amster, I. J., Space charge effects on mass accuracy for multiply charged ions in ESI-FTICR. Int. J. Mass Spectrom., 222, (2003). 12) Beynon, J. H., High resolution mass spectrometry of organic materials. Advances in Mass Spectrometry, (1959). 13) Quisenberry, K. S., Scolman, T. T. and Nier, A. O., Atomic masses of H 1, D 2, C 12 and S 32. Phys. Rev., 102, (1956). 14) Nier, A. O., Improvements in double-focussing mass spectrometry. Nuclear masses and their determination, in Nuclear Masses and their Determination, Hintenberger, H., ed, , Pergamon Press (1957). 15) Craig, R. D., Green, B. N. and Waldron, J. D., Application of high resolution mass spectrometry in organic chemistry. Chimia, 17, (1963). 16) Biemann, K., Utility of exact mass measurement. Methods in Enzymology, 193, (1990). 17) Marshall, A. G., Hendrickson, C. L. and Jackson, G. S., Fourier transform ion cyclotron resonance mass spectrometry: A Primer. Mass Spectrom. Rev., 17, 1-35 (1998). Page 17
25 18) Tyler, A. N., Clayton, E. and Green, B. N., Exact mass measurement of polar organic molecules at low resolution using electrospray ionisation and a quadrupole mass spectrometer. Anal. Chem., 68, (1996). Page 18
26 Glossary of Terms The terms in this Glossary originate from referenced sources (a-d). Other similar definitions exist in the scientific literature and may be regarded as equally valid. Where possible definitions have been used which most clearly convey the meaning of the term. Accuracy a A quantity referring to the difference between the mean of a set of results or an individual result and the value that is accepted as the true value for the quantity measured. AccMass Colloquial term used for accurate mass or accurate mass measurement. Accurate mass b Accurate mass is the measured m/z of an ion and, strictly speaking, should be referred to as measured accurate mass. It is used when reporting the mass to some number of decimal places (usually a minimum of three). Accurate mass measurement b The determination of accurate mass. Atomic weight b The atomic weight of an element is the weighted average of the naturally occurring stable isotopes of an element. Average molecular weight/ average molecular mass b The average mass is calculated using all the isotopes of each element along with their natural abundance. It is calculated using the atomic weights of the elements from which the molecule is composed (See Atomic weight). Calculated exact mass b The mass determined by summing the masses of the individual isotopes that compose a fragment or molecule ion. It is based on a single mass unit being equal to 1/12 the mass of the most abundant naturally occurring stable isotope of carbon. Centroid c The centroid of a peak is its centre of gravity and is that point on the peak at which the mass is measured. It may be determined in different ways. Page 19
27 Centroiding The process by which the centroid of a peak profile is determined. Continuum Spectrum c One displaying the full profile (height and width) of the detected signal (peak) for an ion. Decade b An order of magnitude change in m/z range (for example m/z or m/z ). Used in description of magnet scan speed (seconds/decade) for magnetic sector instruments where an exponential magnet downscan is used. ESI d Electrospray ionisation Exact mass b Equivalent to calculated exact mass of a monoisotopic ion, radical or molecule. FAB d Fast atom bombardment as a method of ionisation. FTICRMS d This refers to Fourier Transform ion cyclotron resonance mass spectrometry, also known as Fourier Transform mass spectrometry (FTMS). FTMS See FTICRMS. Isotope Cluster b A group of peaks close to one another that represent ions with the same elemental composition but of a different isotopic composition. Isotopes a Forms of an element (nuclide) where the numbers of neutrons are different leading to different atomic weights, for example 12 C and 13 C. MALDI d Matrix-assisted laser desorption/ionisation Page 20
28 Molecular Mass b The mass of a molecule or molecule ion. Monoisotopic ion b The ion comprised of the most abundant naturally occurring stable isotope of each of the elements making up the ion. Most abundant mass b This is represented by the most abundant ion in an isotope cluster. m/z b Mass-to-charge ratio (where z is numerically equivalent to e, the mass of the electron, which is x g) Nominal mass ion b The integer mass of the ion comprised of the integer masses of the most abundant naturally occurring stable isotopes of the elements making up the ion. Peak Profile See Continuum Spectrum Precision a The closeness of agreement between the independent results obtained when applying the experimental procedure under prescribed conditions. Resolution b Frequently and incorrectly used interchangeably with resolving power ; however, strictly speaking it is the measure of the separation of two mass spectral peaks ( m at m). m is the difference between m and the value of the next highest m/z value ion that can be separated from m, in m/z units. See also Section 3.3. Resolving Power b The resolving power of a mass spectrometer is defined in terms of its capacity to separate ions of adjacent m/z. The resolving power necessary to separate masses m and (m+ m) respectively is given by: See also Section 3.3. R = m/ m Page 21
29 Thomson b (Th) The name for an m/z unit or increment. TOFMS c Time-of-flight mass spectrometer. Page 22
30 Glossary References a) Guidelines for Achieving High Accuracy in Isotope Dilution Mass spectrometry (IDMS); edited by M. Sargent, C. Harrington & R. Harte. Published by RSC (UK) (2002). b) Sparkman, David O. in Mass Spectrometry Desk Reference, 32-33, Global View Publishing (2000). c) Base Peak Mass Spectrometry Glossary of Terms. Website: education_dets ,00.html d) British Mass Spectrometry Society Glossary. Website: Page 23
31 Bibliography General Quisenberry, K. S., Scolman,T. T. and Nier, A. O., Atomic masses of H 1, D 2, C 12 and S 32. Phys. Rev., 102, (1956). Beynon, J. H., High resolution mass spectrometry of organic materials. Advances in Mass Spectrometry, (1959). Beynon, J. H., Mass spectrometry and its applications to organic chemistry. Elsevier (1960). Biemann, K., Mass spectrometry-organic chemical applications. McGraw-Hill (1962). Sack, T. M., Lapp, R. L., Gross, M. L. and Kimble, B. J., A method for the statistical evaluation of accurate mass measurement quality. Int. J. Mass Spectrom. Ion Processes, 61, (1984). Biemann, K. Utility of exact mass measurement. Methods in Enzymology, 193, (1990). Gross, M. L., Accurate masses for structure confirmation. J. Am. Soc. Mass. Spectrom., 5, 57 (1994). Guan, S., Marshall, A. G. and Scheppele, S. E., Resolution and chemical formula identification of aromatic hydrocarbons and aromatic compounds containing sulfur, nitrogen, or oxygen in petroleum distillates and refinery streams. Anal. Chem., 68, (1996). Zubarev, R. A., Håkansson, P. and Sundqvist, B., Accuracy requirements for peptide characterization by monoisotopic molecular mass measurements. Anal. Chem., 68, (1996). Quantifying uncertainty in analytical measurements. EURACHEM guide, LGC, Teddington (2000). Grange, A. H., Genicola, F. A. and Sovocool, G. W., Utility of three types of mass spectrometers for determining elemental compositions of ions formed from chromatographically separated compounds. Rapid Commun. Mass Spectrom., 16, (2002). Page 24
32 Price, P. C., Gale, P. J., Loo, J. A, Heller, D. N, Richardson, S. D. and Duncan, M. W., ASMS guidelines for exact mass measurement and elemental composition new perspectives. Proceedings of the 50 th Annual Conference on Mass Spectrometry and Allied Topics, Orlando FL, (2002). Bristow, A. W. T. and Webb, K. S., Intercomparison study on accurate mass measurements of small molecules in mass spectrometry. J. Am. Soc. Mass. Spectrom., 14, (2003). Magnetic Sector Nier, A. O., Improvements in double-focussing mass spectrometry. Nuclear masses and their determination, in Nuclear Masses and their Determination, Hintenberger, H., ed, , Pergamon Press (1957). Craig, R. D., Green, B. N. and Waldron, J. D., Application of high resolution mass spectrometry in organic chemistry. Chimia, 17, (1963). McMurray, W. J., Green, B. N. and Lipsky, S. R., Fast scan high resolution mass spectrometry. Operating parameters and its tandem use with gas chromatography. Anal. Chem., 38, (1966). Perkins, G., Pullen, F. and Thompson, C., Automated high resolution mass spectrometry for the synthetic chemist. J. Am. Soc. Mass Spectrom., 10, (1999). FTMS Marshall, A. G., Hendrickson, C. L. and Jackson, G. S., Fourier transform ion cyclotron resonance mass spectrometry: A Primer. Mass Spectrometry Reviews, 17, 1-35 (1998). Easterling, M. L., Mize, T. H. and Amster, I. J., Routine part-per-million accuracy for highmass ions: space-charge effects in MALDI FT-ICR. Anal. Chem., 71, (1999). Burton, R. D., Matuszak, K. P., Watson, C. H. and Eyler, J. R., Exact mass measurements using a 7 tesla Fourier transform ion cyclotron resonance mass spectrometer in a good laboratory practices-regulated environment. J. Am. Soc. Mass Spectrom., 10, (1999). Bruce, J. E., Anderson, G. A., Brands, M. D., Pasa-Tolic, L. and Smith, R. D., Obtaining more accurate Fourier transform ion cyclotron resonance mass measurements without internal standards using multiply charged ions. J. Am. Soc. Mass Spectrom., 11, (2000). Page 25
33 O Connor, P. B. and Costello, C. E., Internal calibration on adjacent samples (InCAS) with Fourier transform mass spectrometry. Anal. Chem., 72, (2000). Sargent, M. and O Connor, G., Feasibility study: Mass spectrometry techniques for accurate molecular weight determinations of large molecules. Reference number LGC/VAM/2001/026. Available from the author upon request. Marshall, A.G., Scaling MS plateaus with high-resolution FT-ICRMS. Anal. Chem., 74, 253A- 259A (2002). Quenzer, T. L., Robinson, J. M., Bolanios, B., Milgram, E. and Greig, M. J., Automated accurate mass analysis using FTICR mass spectrometry. Proceedings of the 50 th Annual Conference on Mass Spectrometry and Allied Topics, Orlando FL, (2002). Null, A. P. and Muddiman, D. C., Determination of a correction to improve mass measurement accuracy of isotopically unresolved polymerase chain reaction amplicons by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun. Mass Spectrom., 17, (2003). Taylor, P. K. and Amster, I. J., Space charge effects on mass accuracy for multiply charged ions in ESI-FTICR. Int. J. Mass Spectrom., 222, (2003). TOF Guilhaus, M., Mlynski, V. and Selby, D., Perfect timing: time-of-flight mass spectrometry. Rapid Commun. Mass Spectrom., 11, (1997). Eckers, C., Wolff, J.-C., Haskins, N. J., Sage, A. B., Giles, K. and Bateman, R., Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept. Anal. Chem., 72, (2000). Blom, K. F., Estimating the precision of exact mass measurements on an orthogonal time-offlight mass spectrometer. Anal Chem.,73, (2001). Maizels, M. and Budde, W. L., Exact mass measurements for confirmation of pesticides and herbicides determined by liquid chromatography/time-of-flight mass spectrometry. Anal. Chem., 73, (2001). Page 26
34 Wolff, J.-C., Eckers, C., Sage, A. B., Giles, K. and Bateman, R., Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 2. Applications using the dualelectrospray ion source. Anal. Chem., 73, (2001). Charles, L., Flow injection of the lock mass standard for accurate mass measurement in electrospray ionization time-of-flight mass spectrometry coupled with liquid chromatography. Rapid Commun. Mass Spectrom., 17, (2003). Fang, L., Demee, M., Cournoyer, J., Sierra, T., Young, C. and Yan, B., Parallel highthroughput accurate mass measurement using a nine-channel multiplexed electrospray liquid chromatography ultraviolet time-of-flight mass spectrometry system. Rapid Commun. Mass Spectrom., 17, (2003). Wu, J. and McAllister, H., Exact mass measurement on an electrospray ionization time-offlight mass spectrometer: error distribution and selective averaging. J. Mass Spectrom., 38, (2003). MALDI-TOF Edmondson, R. D. and Russell, D. H., Evaluation of matrix-assisted laser desorption ionization-time-of-flight mass measurement accuracy by using delayed extraction. J. Am. Soc.Mass Spectrom., 7, (1996). Russell, D. H. and Edmondson, R. D., High resolution mass spectrometry and accurate mass measurements with emphasis on the characterization of peptides and proteins by matrixassisted laser desorption/ionization time-of-flight mass spectrometry. J. Mass Spectrom., 32, (1997). Edmondson, R. D. and Russell, D. H., High-resolution mass spectrometry and accurate mass measurements of biopolymers using MALDI-TOF. Mass Spectrometry of Biological Materials (2nd Edition) (1998). Vestal, M. and Juhasz, P., Resolution and mass accuracy in matrix-assisted laser desorption ionization-time-of-flight. J.Am. Soc.Mass Spectrom., 9, (1998). Fukai, T., Kuroda, J. and Nomura, T., Accurate mass measurement of low molecular weight compounds by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. J.Am. Soc. Mass Spectrom., 11, (2000). Page 27
35 Quadrupole and Quadrupole-TOF Tyler, A. N., Clayton, E. and Green, B. N., Exact mass measurement of polar organic molecules at low resolution using electrospray ionisation and a quadrupole mass spectrometer. Anal. Chem., 68, (1996). Roboz, J., Holland, J. F., McDowell, M. A. and Hillmer, M. J., Accurate mass measurement in continuous flow fast atom bombardment quadrupole mass spectrometry. Rapid Commun.Mass Spectrom., 2, 64-6 (1988). Wolff, J.-C., Fuentes, T. R. and Taylor, J., Investigations into the accuracy and precision obtainable on accurate mass measurements on a quadrupole orthogonal acceleration time-offlight mass spectrometer using liquid chromatography as sample introduction. Rapid Commun. Mass Spectrom., 17, (2003). Page 28
36 Appendix 1: Journal Requirements for Accurate Mass Data Used for Formula Confirmation Very few journals publish guidance to authors on the use of accurate mass data for formula confirmation. Some examples of published guidance are given below, which were correct at the time of writing (March 2004). The most detailed and informative are those of the Journal of the American Society for Mass Spectrometry. Journal of the American Society for Mass Spectrometry For publication of accurate mass data used to confirm the identities of synthetic and natural products, report the uncertainty in the accurate mass measurement used for formula verification along with the result. The acceptable uncertainty in a measurement by any analytical method must be adequate for the intended use of the data. Evaluate the uncertainty of accurate mass measurement by any statistically valid method. Determine, for example, the precision and accuracy of replicate measurements or evaluate the performance characteristics of the mass spectrometer. Consider all candidates fitting the experimentally determined value and its reported uncertainty when the result of accurate mass measurement is used for formula confirmation. Do not set fixed acceptable error limits for exact mass measurement. This is illustrated by the discussion below: When valence rules and candidate compositions encompassing C 0-100, H 3-74, O 0-4 and N 0-4 are considered at nominal parent m/z of 118, there are no candidate formulae within 34 ppm of each other. When the ion is of m/z and the formulae are in the range C 0-100, H 3-74, O 0-4 and N 0-4, there are 626 candidate formulae that are possible within 5 ppm. Thus, for a measurement at m/z 118, an error of only 34 ppm uniquely defines a particular formula, whereas at m/z 750, an error (and precision) of ppm would be required to eliminate all extraneous possibilities. Journal of Organic Chemistry Summary information Compound Characterisation High resolution mass spectrometry data (HRMS) may be reported to support the molecular formula assignment. The structures of peptides and oligonucleotides may be established by providing evidence about sequence and mass. Typically, a sequence will be accompanied by HRMS data that establishes the molecular weight and formula. HRMS data may be used to support a structure assignment but cannot be used as a criterion of purity. (Note no criteria for quality are listed.) American Chemical Society Characterization Requirements for Routine Organic Substances (Only mass spectrometry requirements are detailed here) Molecular Weight. Evidence of molecular weight should be provided, especially if elemental analysis was not performed. Low resolution MS data under conditions that minimize fragmentation are acceptable. If there is a specific need to distinguish alternative formulas with the same molecular mass (within one amu), then HRMS data are necessary. Page 29
37 ISBN
Pesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
Mass Spectrometry. Overview
Mass Spectrometry Overview Mass Spectrometry is an analytic technique that utilizes the degree of deflection of charged particles by a magnetic field to find the relative masses of molecular ions and fragments.2
13C NMR Spectroscopy
13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number
Micromass LCT User s Guide
Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project
CHE334 Identification of an Unknown Compound By NMR/IR/MS
CHE334 Identification of an Unknown Compound By NMR/IR/MS Purpose The object of this experiment is to determine the structure of an unknown compound using IR, 1 H-NMR, 13 C-NMR and Mass spectroscopy. Infrared
Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software
Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software Mark Belmont and Alexander N. Semyonov, Thermo Fisher Scientific, Austin, TX, USA Ming Gu, Cerno Bioscience,
PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW
OVERVIEW Exact mass LC/MS analysis using an orthogonal acceleration time of flight (oa-tof) mass spectrometer is a well-established technique with a broad range of applications. These include elemental
AMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis
Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis B. Apicella*, M. Passaro**, X. Wang***, N. Spinelli**** [email protected]
Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis
Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis Main points of the chapter 1. Hydrogen Nuclear Magnetic Resonance a. Splitting or coupling (what s next to what) b. Chemical shifts (what type is it) c. Integration
Nuclear Structure. particle relative charge relative mass proton +1 1 atomic mass unit neutron 0 1 atomic mass unit electron -1 negligible mass
Protons, neutrons and electrons Nuclear Structure particle relative charge relative mass proton 1 1 atomic mass unit neutron 0 1 atomic mass unit electron -1 negligible mass Protons and neutrons make up
[ Care and Use Manual ]
PREP Calibration Mix DIOS Low i. Introduction Pre-packaged PREP Calibration Mixtures eliminate the need to purchase and store large quantities of the component calibration reagents, simplifying sample
Best Practice Guide. for Generating Mass Spectra. Authors: Vicki Barwick John Langley Tony Mallet Bridget Stein Ken Webb
Best Practice Guide for Generating Mass Spectra Best Practice Guide for Generating Mass Spectra Authors: Vicki Barwick John Langley Tony Mallet Bridget Stein Ken Webb BEST PRACTICE GUIDE FOR GENERATING
How To Use Gc-Ms
The CHROMacademy Essential Guide Understanding GC-MS Analysis Part 1 Speakers John Hinshaw GC Dept. Dean CHROMacademy Tony Taylor Technical Director Crawford Scientific Moderator M ( g ) e M ( g ) 2e Peter
F321 THE STRUCTURE OF ATOMS. ATOMS Atoms consist of a number of fundamental particles, the most important are... in the nucleus of an atom
Atomic Structure F32 TE STRUCTURE OF ATOMS ATOMS Atoms consist of a number of fundamental particles, the most important are... Mass / kg Charge / C Relative mass Relative Charge PROTON NEUTRON ELECTRON
Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio
an ABC Laboratories white paper Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio A. Sen, R. Dunphy, L. Rosik Analytical
Background Information
1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software
Chapter 1: Moles and equations. Learning outcomes. you should be able to:
Chapter 1: Moles and equations 1 Learning outcomes you should be able to: define and use the terms: relative atomic mass, isotopic mass and formula mass based on the 12 C scale perform calculations, including
Amount of Substance. http://www.avogadro.co.uk/definitions/elemcompmix.htm
Page 1 of 14 Amount of Substance Key terms in this chapter are: Element Compound Mixture Atom Molecule Ion Relative Atomic Mass Avogadro constant Mole Isotope Relative Isotopic Mass Relative Molecular
Mass Spectrometry Signal Calibration for Protein Quantitation
Cambridge Isotope Laboratories, Inc. www.isotope.com Proteomics Mass Spectrometry Signal Calibration for Protein Quantitation Michael J. MacCoss, PhD Associate Professor of Genome Sciences University of
Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference
Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference Abstract The advantages of mass spectrometry (MS) in combination with gas
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method Introduction During the last decade, the complexity of samples
LC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer
What is ICP-MS? and more importantly, what can it do? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations. The technique was commercially
Tutorial 4.6 Gamma Spectrum Analysis
Tutorial 4.6 Gamma Spectrum Analysis Slide 1. Gamma Spectrum Analysis In this module, we will apply the concepts that were discussed in Tutorial 4.1, Interactions of Radiation with Matter. Slide 2. Learning
For example: (Example is from page 50 of the Thinkbook)
SOLVING COMBINED SPECTROSCOPY PROBLEMS: Lecture Supplement: page 50-53 in Thinkbook CFQ s and PP s: page 216 241 in Thinkbook Introduction: The structure of an unknown molecule can be determined using
Appendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
0 10 20 30 40 50 60 70 m/z
Mass spectrum for the ionization of acetone MS of Acetone + Relative Abundance CH 3 H 3 C O + M 15 (loss of methyl) + O H 3 C CH 3 43 58 0 10 20 30 40 50 60 70 m/z It is difficult to identify the ions
# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
CHEMICAL FORMULAS AND FORMULA WEIGHT CALCULATIONS
CHEMICAL FORMULAS AND FORMULA WEIGHT CALCULATIONS 1. THE MEANING OF A CHEMICAL FORMULA A chemical formula is a shorthand method of representing the elements in a compound. The formula shows the formulas
HRMS in Clinical Research: from Targeted Quantification to Metabolomics
A sponsored whitepaper. HRMS in Clinical Research: from Targeted Quantification to Metabolomics By: Bertrand Rochat Ph. D., Research Project Leader, Faculté de Biologie et de Médecine of the Centre Hospitalier
Getting the most from this book...4 About this book...5
Contents Getting the most from this book...4 About this book....5 Content Guidance Topic 1 Atomic structure and the periodic table...8 Topic 2 Bonding and structure...14 Topic 2A Bonding....14 Topic 2B
SPECIAL FEATURE: TUTORIAL
JOURNAL OF MASS SPECTROMETRY, VOL. 32, 263È276 (1997) SPECIAL FEATURE: TUTORIAL High-resolution Mass Spectrometry and Accurate Mass Measurements with Emphasis on the Characterization of Peptides and Proteins
Guide to achieving reliable quantitative LC-MS measurements
Guide to achieving reliable quantitative LC-MS measurements Guide to achieving reliable quantitative LC-MS measurements RSC Analytical Methods Committee Editor Mike Sargent First Edition 2013 Contributors
API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
AxION edoor. Web-Based, Open-Access Mass Spectrometry Software
AxION edoor Web-Based, Open-Access Mass Spectrometry Software 2 AxION edoor is the open-access software solution for today s fast-paced laboratory. It is designed to operate and optimize the management
How To Build An Amd Quas 3 Ar Mass Spectrometer
Classical and special AMD Magnetic Sector mass spectrometers (extracted from power point presentations) High Resolution Mass Spectromter AMD 402/403 S 6 High Resolution Mass Spectrometer AMD 604 S 8 Version
Aiping Lu. Key Laboratory of System Biology Chinese Academic Society [email protected]
Aiping Lu Key Laboratory of System Biology Chinese Academic Society [email protected] Proteome and Proteomics PROTEin complement expressed by genome Marc Wilkins Electrophoresis. 1995. 16(7):1090-4. proteomics
Infrared Spectroscopy 紅 外 線 光 譜 儀
Infrared Spectroscopy 紅 外 線 光 譜 儀 Introduction Spectroscopy is an analytical technique which helps determine structure. It destroys little or no sample (nondestructive method). The amount of light absorbed
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can
Tuning & Mass Calibration
Tuning & Mass Calibration 1 1 The Sample List Sample List Name Project Name 2 The sample list is the top level screen in the TurboMass Gold Software. Data storage is set up in PROJECT files and within
amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS
amazon SL Setting New Standards in Performance, Simplicity and Value Innovation with Integrity Ion Trap Best-In-Class Ion Trap Mass Spectrometer for Routine Analysis The amazon SL entry-level system is
Copyright 2007 Casa Software Ltd. www.casaxps.com. ToF Mass Calibration
ToF Mass Calibration Essentially, the relationship between the mass m of an ion and the time taken for the ion of a given charge to travel a fixed distance is quadratic in the flight time t. For an ideal
The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring
The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring Delivering up to 2500 MRM Transitions per LC Run Christie Hunter 1, Brigitte Simons 2 1 AB SCIEX,
Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays
Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Scheduled MRM HR Workflow on the TripleTOF Systems Jenny Albanese, Christie Hunter AB SCIEX, USA Targeted quantitative
Suggested solutions for Chapter 3
s for Chapter PRBLEM Assuming that the molecular ion is the base peak (00% abundance) what peaks would appear in the mass spectrum of each of these molecules: (a) C5Br (b) C60 (c) C64Br In cases (a) and
Application of Structure-Based LC/MS Database Management for Forensic Analysis
Cozette M. Cuppett and Michael P. Balogh Waters Corporation, Milford, MA USA Antony Williams, Vitaly Lashin and Ilya Troisky Advanced Chemistry Development, Toronto, ntario, Canada verview Application
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM Technical Overview Introduction The 5975A and B series mass selective detectors (MSDs) provide
Solving Spectroscopy Problems
Solving Spectroscopy Problems The following is a detailed summary on how to solve spectroscopy problems, key terms are highlighted in bold and the definitions are from the illustrated glossary on Dr. Hardinger
Molecular Formula Determination
Molecular Formula Determination Classical Approach Qualitative elemental analysis Quantitative elemental analysis Determination of empirical formula Molecular weight determination Molecular formula determination
Secondary Ion Mass Spectrometry
Secondary Ion Mass Spectrometry A PRACTICAL HANDBOOK FOR DEPTH PROFILING AND BULK IMPURITY ANALYSIS R. G. Wilson Hughes Research Laboratories Malibu, California F. A. Stevie AT&T Bell Laboratories Allentown,
VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)
INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY
STANDARD OPERATING PROCEDURES
PAGE: 1 of 33 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS
Contents. Contributors. 1 Quality control and regulation 1 C.J. MOORES
Contents Contributors Preface xiii xiv 1 Quality control and regulation 1 C.J. MOORES 1.1 Introduction 1 1.2 The quality of medicines 2 1.2.1 The meaning of quality 2 1.2.2 Medicines are special 3 1.2.3
Calculating the Degrees of Unsaturation From a Compound s Molecular Formula
Calculating the Degrees of Unsaturation From a Compound s Molecular Formula Alkanes have the molecular formula C n. Alkanes are saturated hydrocarbons because each member of the family has the maximum
Proton Nuclear Magnetic Resonance ( 1 H-NMR) Spectroscopy
Proton Nuclear Magnetic Resonance ( 1 H-NMR) Spectroscopy Theory behind NMR: In the late 1940 s, physical chemists originally developed NMR spectroscopy to study different properties of atomic nuclei,
Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA 94305-5080
Training on the ZQ Open access MS Questions? Contact Dr. Allis Chien [email protected] 650-723-0710 0710 STANFORD UNIVERSITY MASS SPECTROMETRY STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD
Nuclear Magnetic Resonance notes
Reminder: These notes are meant to supplement, not replace, the laboratory manual. Nuclear Magnetic Resonance notes Nuclear Magnetic Resonance (NMR) is a spectrometric technique which provides information
UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs
Application Note: 439 UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela UHPLC System MSQ Plus MS Detector Drugs
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry BY GHULAM A. SHABIR Introduction Methods Validation: Establishing documented evidence that provides a high
The Mole Concept. The Mole. Masses of molecules
The Mole Concept Ron Robertson r2 c:\files\courses\1110-20\2010 final slides for web\mole concept.docx The Mole The mole is a unit of measurement equal to 6.022 x 10 23 things (to 4 sf) just like there
AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs
AB SCIEX TOF/TOF 4800 PLUS SYSTEM Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM It s just what you expect from the industry leader. The AB SCIEX 4800 Plus MALDI TOF/TOF
Electrospray Ion Trap Mass Spectrometry. Introduction
Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic
List the 3 main types of subatomic particles and indicate the mass and electrical charge of each.
Basic Chemistry Why do we study chemistry in a biology course? All living organisms are composed of chemicals. To understand life, we must understand the structure, function, and properties of the chemicals
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Abstract Presented here is a case study of a walk-up liquid chromatography
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1
GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert, Michel Lhermitte, Frederic Grisel Laboratoire de Toxicologie & Génopathologie, CHRU Lille, France Waters Corporation, Guyancourt,
Tutorial for Proteomics Data Submission. Katalin F. Medzihradszky Robert J. Chalkley UCSF
Tutorial for Proteomics Data Submission Katalin F. Medzihradszky Robert J. Chalkley UCSF Why Have Guidelines? Large-scale proteomics studies create huge amounts of data. It is impossible/impractical to
OLIVÉR BÁNHIDI 1. Introduction
Materials Science and Engineering, Volume 39, No. 1 (2014), pp. 5 13. DETERMINATION OF THE ANTIMONY- AND STRONTIUM- CONTENT OF ALUMINIUM ALLOYS BY INDUCTIVELY COUPLED PLASMA ATOM EMISSION SPECTROMETRY
L. Yu et al. Correspondence to: Q. Zhang ([email protected])
Supplement of Atmos. Chem. Phys. Discuss., 5, 967 974, 5 http://www.atmos-chem-phys-discuss.net/5/967/5/ doi:.594/acpd-5-967-5-supplement Author(s) 5. CC Attribution. License. Supplement of Molecular transformations
Element of same atomic number, but different atomic mass o Example: Hydrogen
Atomic mass: p + = protons; e - = electrons; n 0 = neutrons p + + n 0 = atomic mass o For carbon-12, 6p + + 6n 0 = atomic mass of 12.0 o For chlorine-35, 17p + + 18n 0 = atomic mass of 35.0 atomic mass
Simple vs. True. Simple vs. True. Calculating Empirical and Molecular Formulas
Calculating Empirical and Molecular Formulas Formula writing is a key component for success in chemistry. How do scientists really know what the true formula for a compound might be? In this lesson we
Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
Bruker ToxScreener TM A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS ToxScreener - Get the Complete Picture Forensic laboratories are frequently required
Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.
Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
Organic Chemistry Tenth Edition
Organic Chemistry Tenth Edition T. W. Graham Solomons Craig B. Fryhle Welcome to CHM 22 Organic Chemisty II Chapters 2 (IR), 9, 3-20. Chapter 2 and Chapter 9 Spectroscopy (interaction of molecule with
TECHNICAL BULLETIN. ProteoMass Peptide & Protein MALDI-MS Calibration Kit. Catalog Number MSCAL1 Store at Room Temperature
ProteoMass Peptide & Protein MALDI-MS Calibration Kit Catalog Number MSCAL1 Store at Room Temperature TECHNICAL BULLETIN Description This kit provides a range of standard peptides and proteins for the
Waters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
Introduction to Fourier Transform Infrared Spectrometry
Introduction to Fourier Transform Infrared Spectrometry What is FT-IR? I N T R O D U C T I O N FT-IR stands for Fourier Transform InfraRed, the preferred method of infrared spectroscopy. In infrared spectroscopy,
High resolution mass spectrometry (HRMS*) in Graz
High resolution mass spectrometry (HRMS*) in Graz 10.2.2012 * Instruments with high resolution where exact mass measurements can be performed 1 HRMS in Graz s and Ionization Techniques 2 6 3 5 4 1 TU Graz
electron does not become part of the compound; one electron goes in but two electrons come out.
Characterization Techniques for Organic Compounds. When we run a reaction in the laboratory or when we isolate a compound from nature, one of our first tasks is to identify the compound that we have obtained.
How to Quickly Solve Spectrometry Problems
How to Quickly Solve Spectrometry Problems You should be looking for: Mass Spectrometry (MS) Chemical Formula DBE Infrared Spectroscopy (IR) Important Functional Groups o Alcohol O-H o Carboxylic Acid
NMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum.
NMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum. Dr. John Jackowski Chair of Science, Head of Chemistry Scotch College Melbourne [email protected]
Symmetric Stretch: allows molecule to move through space
BACKGROUND INFORMATION Infrared Spectroscopy Before introducing the subject of IR spectroscopy, we must first review some aspects of the electromagnetic spectrum. The electromagnetic spectrum is composed
GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.
GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS October 2004 APVMA PO Box E240 KINGSTON 2604 AUSTRALIA http://www.apvma.gov.au
World s Best Oil in Water Analyzers
World s Best Oil in Water Analyzers Advanced Water Measurement and Analysis Advanced Sensors Ltd is the leading global supplier of Oil in Water analyzers to the Oil and Gas Industries. We provide innovative
Signal to Noise Instrumental Excel Assignment
Signal to Noise Instrumental Excel Assignment Instrumental methods, as all techniques involved in physical measurements, are limited by both the precision and accuracy. The precision and accuracy of a
Sample Exercise 8.1 Magnitudes of Lattice Energies
Sample Exercise 8.1 Magnitudes of Lattice Energies Without consulting Table 8.2, arrange the following ionic compounds in order of increasing lattice energy: NaF, CsI, and CaO. Analyze: From the formulas
Signal, Noise, and Detection Limits in Mass Spectrometry
Signal, Noise, and Detection Limits in Mass Spectrometry Technical Note Chemical Analysis Group Authors Greg Wells, Harry Prest, and Charles William Russ IV, Agilent Technologies, Inc. 2850 Centerville
Guidance for Industry
Guidance for Industry Q2B Validation of Analytical Procedures: Methodology November 1996 ICH Guidance for Industry Q2B Validation of Analytical Procedures: Methodology Additional copies are available from:
MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples
MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples Fast and Efficient Data Review, with Automatic Flagging of Outlier Results Adrian M. Taylor and Michael
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
Chapter Five: Atomic Theory and Structure
Chapter Five: Atomic Theory and Structure Evolution of Atomic Theory The ancient Greek scientist Democritus is often credited with developing the idea of the atom Democritus proposed that matter was, on
APPENDIX N. Data Validation Using Data Descriptors
APPENDIX N Data Validation Using Data Descriptors Data validation is often defined by six data descriptors: 1) reports to decision maker 2) documentation 3) data sources 4) analytical method and detection
Molecular Models Experiment #1
Molecular Models Experiment #1 Objective: To become familiar with the 3-dimensional structure of organic molecules, especially the tetrahedral structure of alkyl carbon atoms and the planar structure of
Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)
Page 1 Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT) ECC RECOMMENDATION (06)01 Bandwidth measurements using FFT techniques
Kendrick Mass Defect Spectrum: A Compact Visual Analysis for Ultrahigh-Resolution Broadband Mass Spectra
JSB is an authorised partner of Kendrick Mass Defect Spectrum: A Compact Visual Analysis for Ultrahigh-Resolution Broadband Mass Spectra Christine A. Hughey, Christopher L. Hendrickson, Ryan P. Rodgers,
INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS
AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT) The GC/MS/MS Solution for the Work You Do The ideal solution for industrial,