MICRO FIBER OPTIC CABLE BLOWING MACHINE WITH ELECTRIC
|
|
|
- Cable Blowing Machines
- 9 years ago
- Views:
Transcription
1 ELECTROFOK MACHINES MICRO FIBER OPTIC CABLE BLOWING MACHINE WITH ELECTRIC fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES
2 ABOUT US Our company ever since its incorporation in the telecommunication sector has been operating the machine. Our company since its establishment until the superior service quality and customer satisfaction continues to be one of the leading companies. Fiber Optic Cable Blowing Machine (FOK), a single supplier and telecommunication in TURKEY. Turk Telekom, Turkcell and the VODAFONE S FOK uses subcontractors in Turkey. According to information from users FOK in 1999 to the present continuous revisions are made more useful. Our services include; machine spare parts manufacturing, a complete machine manufacture, stockpiling of machine parts, components or systems required the development of machines with the development of R & D activities are. Our Vision Profitable and sustainable growth to ensure long-term customer and employee satisfaction, and satisfaction as well as aims. Our Mission High standards, quality service in the time of our customers to maximize customer satisfaction and respect the rights. Our products, solutions, after sales service we provide our customers with reliability and high business ethics as the first choice to be a company that creates value for our employees and our customers. Our Quality Policy The fact that customer satisfaction as a priority action in this direction is to provide products and services. For this reason, Complying with the terms of the quality management system, to sustain activity. Ethics, values, respect and team spirit, and the potential to increase customer satisfaction. Improve the competitiveness of the industry by continuously improving staff satisfaction and education. Our employees, customers, suppliers long-term commitment to our organizations and institutions to increase non-cooperation. The provisions of relevant laws and standards to export to the framework. fokmachine.com
3 ELECTROFOK MACHINES 1 MICRO FIBER OPTIC CABLE BLOWING MACHINE WITH ELECTRIC
4 LECTROFOK MACHINES 2E GENERAL DESCRIPTION ELECTROFOK is designed and produced by KOSMAK MACHINE with feedbacks from users who has specialty on cable blowing technologies. Electrofok is using to blow cables from 1mm to 3mm. You need to give us duct diameters in your project before ordering machine.
5 3 1 Cable Blowing Group 3 Air Filter Unit 2 Electric Panel Group 4 Tripod Table Figure 1 Machine consist off our parts as you can see in figure1. Cable blowing group is blowing cable induct with controlling by electric panel. You can control cable blowing speed and direction. You can see the distance of cable you blowed from electric panel. The most important thing of machine is sensor design which prevents breaking cable. Machine stops before breaking cable. Air conditioner system is cleaning air and setting air pressure induct also you can open and close air. You can put machine on desired place and height with tripod table.
6 4E LECTROFOK MACHINES ELECTROFOK
7 5 TECHNICAL PROPERTIES MICRO FOK MICRO FIBER OPTIC CABLE BLOWING MACHINE CONTROL TECHNICIAN NEEDED ELECTRICITY CITY ELECTRIC IS ENOUGH NEEDED AIR 8 BAR -10 METERCUP/MINUTE (NOTE: It can be changed to the different factors) CABLE BLOWING SPEED 0 TO 50 METER/MINUTE DIMENSIONS OF MACHINE 42 cm x 42 cm x 25 cm WEIGHT OF MACHINE 15 KG
8 LECTROFOK MACHINES 6E 1 USING CABLE BLOWING GROUP 1-A) MONTAGING DUCT, NUTRINGS AND O-RINGS Figure 2 6 Duct Montaging: Push the duct to the gauge point the nturn part 2 to fix duct between part 3 and 4 as in the figure 2. Montaging Nutring: The part 6 is nutring in figure 2. When you montage nutring canals must be on the direction of duct. Nutrings must be cutted to take cable outside. Cutted place must be in the underside. Montaging O-rings: Part 5 in figure 2 iso-ring. O-rings is montaging between duct and o-ring as in the figure 2. If you do not montage nutrings like that air leaks happens. 1-B) MONTAGING FIBER OPTIC CABLE AND ADJUSTING SKIDDING CABLE BETWEEN ROLLS 4 Figure 3 Figure 4 Fiber optic cable should be placed on the machine as in the figure 3 and then close machine supper part while pulling cable as in the figure-4. As shown in figure 4, slip page of cable between the wheel scan be easily prevented with adjusting Part 5.
9 7 1-C) CHANGING THE RUBBERIZED WHEELS 7 Figure 5 Figure 6 6 Fiber optic cable is driven by rubberized wheels. By the time some wear will be seen on the wheels. These wheels can easily remove and change with new one as shown in Figure-5 and Figure-6. First, number 6 bolts must be took out soupper and bottom covers will be removed. Then, number 7 bolts on the wheels must be took out. Lastly, both wheels should remove slowly and change with spare ones. 2 INSTRUCTIONS FOR USING CONTROL PANEL Figure Fiber optic cable should drive forward and back with switch 8. With the help of this switch cable will move. - Speed of cable movement can adjust with the help of switch 9. - Switch 10 adjusts the sensitivity of break age sensor. This sensor alarms before the cable breakage. Sensor sensitivity depends on hardness and thickness of the cable. If there is no blockage inside the duct but the machine still alarms, so you should increase the sensitivity of the breakage sensor. - If there is a blockage inside of the HDPE duct, number 11 warning light will signal, and machine will stop. - Switch 12 activates the digital distance gauge. - To reset digital gauge, Switch 12 must turn on while pressing the button 13 (red button) at the same time. - Number 14 digital distance gauge shows the distance of the cable which inside the duct.
10 8E LECTROFOK MACHINES 3 INSTRUCTIONS FOR USING AIR FILTER UNIT Figure 8 Figure Air connection to the machine should be made with the number 15 quick connection part. Number 16 valve opens and closes air in take. Air pressure inside the HDPE duct can adjust with the number 17 regulator. Number 18 gauge shows duct air pressure. Minimum HDPE pipe pressure must be. bar. Air inside of the machine is filtered by air filter unit. Humidity of air fills the number 19 reservoir. Collected water inside the reservoir can easily evacuate with number 20 valve (bluevalve) which lies under the reservoir. 4 FIXING THE TRIPOD Figure 10 Figure 11 Figure 12 Figure For fixin go run fixing the tripod, first of all number 21 bolt should be tightened or loosen as it shown in the Figure 10. Machine is connected to tripod housing via number 22 part as it shown in the Figure11. Length of the tripod legs can adjust with wingnuts shown in the Figure 12. Tripod can be made small and carried easily as it shown in the Figure 13.
11 5 MAINTENANCE OF THE MACHINE 9 Figure 14 Figure 15 Figure 16 Figure To avoid air passage, opposite surfaces of upper and bottom unit must be clean first. And all worn nutrings and o-rings must be replaced with spares as shown in the Figure14. Air filter which lies inside the Air Filter Unit gets dirty by the time. So filter must control often and if it is dirty, it must be cleaned. If there is any obtained visual cracks, filter must replace with spare. To replace the filter; first, number 23 air reservoir must be loosen slightly. After the taking reservoir out, filter retainer part (blackpart) must remove by turning it as shown in the Figure16. The number 24 white part shown in the Figure 17 is the filter of air filter unit.
12 10 ELECTROFOK MACHINES
13 11
14 EC DECLA- RATION OF CONFIRMITY KÖSMAK MAKİNA İNŞAAT TAAHHÜT SANAYİ VE TİCARET LİMİTED ŞİRKETİ According to Machinery Directive 2006/42/EEC Manufacturer: KÖSMAK Makine İnşaat Taahhüt San. ve Tic. Ltd. Şti. Küçük Körfez Sanayi Sitesi 201 Blok No:4 KOCAELİ / TURKEY Declaration: Herewith we declare under our own responsibility that the products designated below Products: KOS type of fiber optic cable blowing machine are manufactured in accordance with the EC Directives Directives: Managing Director Machinery Directive 2006/42/EEC including their amendments. Harmonised Standards: TS EN ISO 12100, EN Kocaeli, 2014
15 FIBER OPTIC CABLE BLOWING MACHINES
16 FIBER OPTIC CABLE BLOWING MACHINES Körfez Küçük Sanayi Sitesi 13. Blok No: İzmit, Kocaeli, TURKEY fokmachine.com
AIR COOLER. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES
AIR COOLER fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES ABOUT US Our company ever since its incorporation in the telecommunication sector has been operating the machine. Our company since its establishment
CPME75-100 CABLE PUSHING MACHINE WITH ELECTRIC MOTOR. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES
CPME75-100 CABLE PUSHING MACHINE WITH ELECTRIC MOTOR fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES ABOUT US Our company ever since its incorporation in the telecommunication sector has been operating
HYDROFOK MACHINES. HYDRAULIC CABLE & TUBE BLOWING MACHINE with HYDRAULIC POWER UNIT) fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES
HYDROFOK MACHINES HYDRAULIC CABLE & TUBE BLOWING MACHINE with HYDRAULIC POWER UNIT) fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES ABOUT US Our company ever since its incorporation in the telecommunication
MINIFOK MACHINES MINI FIBER OPTIC CABLE BLOWING MACHINE. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES
MINIFOK MACHINES MINI FIBER OPTIC CABLE BLOWING MACHINE fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES ABOUT US Our company ever since its incorporation in the telecommunication sector has been operating
FOK MACHINES FIBER OPTIC CABLE BLOWING MACHINES. https://www.fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES
FOK MACHINES fokmachine.com ABOUT US Our company ever since its incorporation in the telecommunication sector has been operating the machine. Our company since its establishment until the superior service
FOK MACHINES FIBRE OPTIC CABLE BLOWING MACHINE USER S BOOK. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES
FOK MACHINES fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES ABOUT US Our company ever since its incorporation in the telecommunication sector has been operating the machine. Our company since its establishment
ELECTROFOK MACHINE. ELEKTROFOK (MICRO FIBER OPTIC CABLE BLOWING MACHINE with ELECTRIC)
ELECTROFOK MACHINE ELEKTROFOK (MICRO FIBER OPTIC CABLE BLOWING MACHINE with ELECTRIC) GENERAL DESCRIPTION ELEKTROFOK is designed and produced with feedbacks from users who has specialty on cable blowing
HYDROFOK (Cable & Tube Blowing Machine with Hydraulic Power Unit)
HYDROFOK (Cable & Tube Blowing Machine with Hydraulic Power Unit) Hydrofok is designed to blow cable and tubes in ducts. GENERAL DESCRIPTION You need to change palette group and some parts to modify machine
KOSMAK MACHINE BUILDING INDUSTRY &TRADE LTD CO.
KOSMAK MACHINE BUILDING INDUSTRY &TRADE LTD CO. FOK FIBRE OPTIC CABLE BLOWING TECHNOLOGY Made in TURKEY 1 CABLE BLOWING IS OUR PROFESSION KOSMAK MACHINE INDUSTRY LTD. CO. is the exclusive authorized producer
PRODUCTS PRODUCTS ABOUT US. www.gmm.com.tr
PRODUCTS Fiber Optic Cable Production Lines Secondary coating line Optical fiber cable stranding line Sheathing line for optical cable Rewinding line for optical cable PRODUCTS Copper Communication Cable
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
Operating Instructions Hand pallet trucks HU Profi. Issue 08.2000
Operating Instructions Hand pallet trucks HU Profi Issue 08.2000 Index 1 Introduction 1.1 Product description 1.2 General information on service and maintenance 1.3 Spare parts 1.4 Dimensions 2 Correct
Operating Instructions Drill rig DRU160
Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work
Revised 02-00 TECHNICAL BULLETIN Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves This technical bulletin covers both cab and chassis leveling valves manufactured by Meritor WABCO. While the
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: 2000 9105.RAVI. Pendant Stations LADY Series
C E R T I F MA N A G E ME N T I E D Net ISO 9001: 2000 9105.RAVI I S Y S T E M Pendant Stations LADY Series 4.1 Pendant Stations LADY Series - LA type single-row Main Features The new LADY series single-row
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
RS Security Co., Ltd. RS Security Co., Ltd is specialized in physical access control turnstiles;
RS Security Co., Ltd Tel: 086755-28935596 Mobile: 08613480168583 www.szrssecurity.com Email: [email protected], Skype: Fiona_szrssecurity BB pin: 271f8b86 RS Security Co., Ltd is specialized in physical
Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 [email protected]
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
ROUGHNECK II Pumpless Drain
SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #
OPERATOR s MANUAL ROLL AND EXTENSION TABLES
OPERATOR s MANUAL ROLL AND EXTENSION TABLES 1 INDEX Page Manufacturer s Information 3 Warnings 4 Risks and Labelling 5 Safety Precautions 6 Warranty 7 Dimensions and Weight 8 Shipping Dimensions 8 Transport
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
CoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
Butt Fusion Welding of HDPE Pipes Work Procedure
Butt Fusion Welding of HDPE Pipes Work Procedure A pipeline is as good as its weakest point. Accordingly it is not only important that quality pipes and components are used in a piping system, but also
Fish Grader User Manual
Fish Grader User Manual 1400 Fish Grader Contents Basic Parts... 2 Set up... 3 Control board needs to be setup... 3 Adjustable legs... 3 Adjustable Inlet cute... 3 Motor... 3 Control-board... 4 Remote
User manual. Leather Side Drum
Leather Side Drum User manual Leather Side Drum 1. Declaration of Accordance Declaration of accordance with European standards Manufacturer: Jasopels Production A/S Phone + 45 76 94 35 00 Address: Fabriksvej
Systems BV. Brief User Manual. INADCO Densimeter. Z:\Documenten\SG-bepaler\Handleiding\eng\Brief User Manual V3_1a.
Brief User Manual INADCO Densimeter Z:\Documenten\SG-bepaler\Handleiding\eng\Brief User Manual V3_1a.doc Page 1 of 13 Z:\Documenten\SG-bepaler\Handleiding\eng\Brief User Manual V3_1a.doc Page 2 of 13 CAUTION:
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,70 29.70
Description Usually, a wet alarm valve station comprise: a Rolland wet alarm valve linked to the water motor gong. a set of valves and by pass used to test the system. a drain valve. a test valve gauges
Machine Standard Configuration Standard Configuration Machine Alignment Capability Process Alignment Capability Core Cycle Time Maximum Print Area Printer Construction ISCAN TM Machine Control Operating
INDEX 1. GENERAL INFORMATION... 3 2. SYSTEM COMPONENTS... 4 3. OPERATING INSTRUCTIONS... 15 4. MAINTENANCE... 18
ISO 9001: 2008 EN ISO 14001: 2004 SECURITY SYSTEMS Tyre Killers INSTALLATION INSTRUCTIONS HYDRAULIC TYRE KILLERS INDEX Page 1. GENERAL INFORMATION... 3 2. SYSTEM COMPONENTS... 4 2.1 Construction...4 2.2
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
DIESEL FUEL CONDITIONING
COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency
Platform Carts. Growing Together
Platform Carts Metazet/FormFlex has developed various types of platform carts for looking after your crop and/ or maintenance work at height. All our platform are easy to use and maintain, and fitted with
Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60
Technology You Can Afford. Quality You Can Trust. Operating Manual Rotary Drum Filter Model: KC10 KC15 KC30 KC60 Koi-Collection Indonesia Tel./Fax: +62-21-82433766 Jl. Raya Parpostel 96 www.koi-collection.com
Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold
Bradlee Boilers Ltd Instruction Manual for starting up Bradlee Hire Boiler from Cold To be read in conjunction with Bradlee Boiler guide to Commissioning Boilers Document Ref: HM001 1. Ensure that all
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
GALATIAN SERIES PCP AIR RIFLE
HATSAN ARMS COMPANY Serious. Solid. Impact. GALATIAN SERIES PCP AIR RIFLE INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE USING YOUR AIR GUN Thank you for choosing Hatsan Galatian air rifle. Always
LIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER
\ INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER Suitability: The IBIS caravan rooftop aircondioner is suitable for installation on caravans and motorhomes provided the roof structure
OPERATING AND MAINTENANCE MANUAL
OPERATING AND MAINTENANCE MANUAL AUTOMATIC SCREEN FILTER FMA SERIE 5000 Sistemas de Filtrado y Tratamiento de Fluidos S.A. Pol. Industrial La Armentera Parc. 86 INDEX INTRODUCTION...3 TECHNICAL CHARACTERISTICS...5
Operating instructions for Electrode sharpening machine WIG 4
Operating instructions for Electrode sharpening machine WIG 4 Original Please keep for further use! Kaindl-Schleiftechnik REILING GmbH D-75203 Königsbach-Stein Remchinger Str. 4 Germany Tel.: +49 7232
DENTAL CHAIR AND UNIT SP- CIELA IMPORTANT
DENTAL CHAIR AND UNIT SP- CIELA OPERATING MANUAL IMPORTANT This manual provides operating instruction for BELMONT SP-CIELA. The instructions contained in this booklet should be thoroughly read and understood
Economy Combo Heat Press Manual Model No.: ECH-800
Economy Combo Heat Press Manual Model No.: ECH-800 CONTENTS I. Assembly Drawing -----------------------------------------------------------------------------------2 II. Technical Parameters ------------------------------------------------------------------------------2
1 TON FOLDING CRANE CFC1000
1 TON FOLDING CRANE CFC1000 OPERATION &MAINTENANCE INSTRUCTIONS 0401 SPECIFICATIONS MAXIMUM SAFE WORKING LOADS (kg) 1 2 3 4 1000 750 500 250 MAXIMUM LIFT HEIGHT - 1920mm HYDRAULIC RAM OIL CAPACITY - 450CC
OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4
OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4 Original Please keep for further use! Kaindl-Schleiftechnik REILING GmbH, D-75203 Königsbach-Stein, Remchinger Str. 4 Germany Tel.: +49 7232/4001-0,
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
INSTRUCTION. Industrial Sewing Machines. No. 010012. First published : June 1997 Second edition : March 2001
INSTRUCTION Industrial Sewing Machines First published : June 1997 Second edition : March 2001 No. 010012 INTRODUCTION Thank you for your purchasing Kansai Special's DLR Series. Read and study this instruction
STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual
STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ODEON IN-WALL TANK K-6283K/ K-6284K/ K-6286K Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid
LIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
Technical Service Bulletin
Subject FOUR WHEEL ALIGNMENT - EZ CAM TM XR CAMBER ANGLE ADJUSTING BOLTS Date Model [X] PARTS MANAGER JANUARY, 2008 2003-2008 TIBURON [X] TECHNICIAN CIRCULATE TO: [ ] GENERAL MANAGER [X] SERVICE ADVISOR
Rear wheel brakes, servicing. Стр. 1 из 45. Note:
Volkswagen Touareg - Rear wheel brakes, servicing Стр. 1 из 45 46-2 Rear wheel brakes, servicing Rear brakes, FN 44 brake caliper, servicing Note: After replacing brake pads, depress brake pedal firmly
ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.
ZAPPY 3 OWNER S MANUAL Read this manual completely before riding your Electric ZAPPY 3. TECHNICAL INFORMATION Model No. : ZAPPY 3 Product size Type of motor Motor power Battery type Battery Charger Charging
Doc. No: 412-121033 Issue: 1 Date: Aug 2014. BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02
Date: Aug 2014 THERMAL TRANSFER CARD PRINTER BTT-02 TABLE OF CONTENTS Introduction... 3 System Contents and Initial Checks... 3 Installation... 4 Preparation of Installation Site... 4 Printer Connections...
OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle
OWNER S MANUAL US Permolock C3 Docking system for Power wheelchair in vehicle How to contact Permobil Head Office of the Permobil group Permolock C3 Docking system for electric wheelchair in vehicle Produced
Espresso coffee grinder
Espresso coffee grinder 40A Espresso grinder 40A (Grey model) Internationally patented models L o n g l i f e, d e s i g n a n d s i l e n c e Silent espresso Fresh ground coffee gives the best espresso
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Oregon Fuel Injection
Corporate Office: P.O. Box 21121, VE Pump Removal and Installation Cummins Lock Timed Applications Removal Clean the exterior of the injection pump and mounting surfaces. 1. Disconnect the fuel return
DIAMOND Retractable Rodding Robot Model SPRAYROD-R
2004-12-21 2 1 (23) DIAMOND Retractable Rodding Robot Model SPRAYROD-R 2004-12-21 2 2 (23) Table of contents 1 TECHNICAL DESCRIPTION...4 1.1 MAIN DETAILS...5 1.2 COMPONENTS DESCRIPTION...5 1.2.1 Pneumatic
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
CFMRI Physiological Monitoring System. Operator s Manual
CFMRI Physiological Monitoring System Operator s Manual This manual provides a quick guidance to using the physiological monitoring system during an MRI session. It is not intended as a substitute for
- 2 - IMPORTANT SAFETY REMINDERS
USER MANUAL IMPORTANT SAFETY REMINDERS This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
How To Shoot An Air Rifle
HATSAN ARMS COMPANY AT44 & AT44-10 Series PCP Air Rifle INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE USING YOUR AIR GUN Thank you for choosing HATSAN AT44 / AT44-10 PCP air rifle. Always use caution
Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used
Luna/200 Luna/275 Ceiling hoist User instruction! Important - warning This manual must be read before the Luna is used This manual is intended for technicians, installers, therapists and other personnel,
SUPER SKUB HYDRA USERS MANUAL AND SPARE PARTS
SUPER SKUB HYDRA USERS MANUAL AND SPARE PARTS Udg. 1 BRUGS- OG VEDLIGEHOLDESESVEJLEDNING PÅ SUPER SKUB HYDRA side 1 Table of contents Machine description... 3 Safety precautions... 4 Operating instructions...
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
Operating instructions. SCORP 220 Plus SCORP 360. Pipe Cutter. Code 790 014 762 Machine-no.:
precision. power. simplicity. Operating instructions Pipe Cutter SCORP 220 Plus SCORP 360 Code 790 014 762 Machine-no.: All rights reserved, in particular the rights of duplication and distribution as
User Manual. Ology. Original user manual
User Manual Ology Original user manual BA_Ology _EN_02_2014 www.steelcase-village.de Table of contents 1 General instructions 1.1 About the Ology product series....................................... 3
Fuel Injection Pump, Rotary (005-014)
Fuel Injection Pump, Rotary View Related Topic Page 1 of 30 Fuel Injection Pump, Rotary (005-014) Table of Contents Summary General Information Preparatory Steps Remove Front Gear Train Rear Gear Train
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
Machine Documentation
Machine Documentation BELKI Oil Separator type 211 0 Tabel of contents: Machine Documention...0 Tabel of contens...1 Description...2 Specifications...3 Diagram...4 Partlist...5 Pumpdrawing...6 Part list
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
User Manual. Studio Rail. Size 60. www.doughty-engineering.co.uk. Version 11.0. www.doughty-engineering.co.uk
User Manual Studio Rail Size 60 Version 11.0 Contents Contents: Introduction... 2 Exclusion of Liability... 2 Safety Instructions... 2 Rail Loading Charts...3-4 Operating Data...5-10 1. Selecting the correct
Model Year: 2010 Model: Prius Doc ID: RM000001Y3B015X. Title: ALIGNMENT / HANDLING DIAGNOSIS: FRONT WHEEL ALIGNMENT: ADJUSTMENT (2010 Prius)
Last Modified: 5-3-2010 6.4 N From: 200904 Model Year: 2010 Model: Prius Doc ID: RM000001Y3B015X Title: ALIGNMENT / HANDLING DIAGNOSIS: FRONT WHEEL ALIGNMENT: ADJUSTMENT (2010 Prius) ADJUSTMENT If the
Wet alarm valves. Wet alarm valves. FM trim
Description Usually, a wet alarm valve station comprise: - a Rolland wet alarm valve linked to the water motor gong. - a set of valves and by pass used to test the system. - a drain valve. - a test valve
WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D-76863 Herxheim Tel. (07276) 96680 FAX 9668-11
The I-PRO Traveller part no. 11440 Thank you for your purchase, please take your time to digest some of the important building tips and the essential matching/adjustment techniques. You will need 8m of
Engineered Material Handling. Overhead Bridge Cranes and Gantry Cranes
TM Engineered Material Handling Overhead Bridge Overhead and Gantry Bridge Cranes and Gantry Cranes Custom Engineered Crane Systems Gantry Cranes EMH builds a complete range of gantry cranes including
Manual piston sampler...m 11
SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr
Operating instructions Cordless K 10253 impact wrench
Operating instructions Cordless K 10253 impact wrench Operational precautions General safety instructions warning! 1. Consider work area environment. Do not expose tools to rain. Do not use tools in damp
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
LINEAR MOTION CONTROL
LINEAR MOTION CONTROL Technical Data Sheet Static Locks RLSS Series Nexen s new generation of linear holding/locking devices take rod locking technology to the next level. With superior performance, these
FAAST. Fire Alarm Aspiration Sensing Technology
FAAST Fire Alarm Aspiration Sensing Technology The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m2 state-ofthe-art facility
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
Auto-belay Cable Replacement Process
Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable
Draining and filling cooling system
Page 1 of 9 Draining and filling cooling system Special tools and workshop equipment required Adapter -V.A.G 1274/8- Pipe -V.A.G 1274/10- Drip tray -V.A.G 1306- or drip tray for workshop hoist -VAS 6208-
Saferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: [email protected] 1115 4G
