DOD ANTI-RAM VEHICLE BARRIERS
|
|
|
- Edgar Bennett Kennedy
- 10 years ago
- Views:
Transcription
1 DEPARTMENT OF DEFENSE US ARMY CORPS OF ENGINEERS PROTECTIVE DESIGN CENTER 1616 Capitol Avenue, Suite 9000 OMAHA, NEBRASKA DOD ANTI-RAM VEHICLE BARRIERS List Date: January 2013 The Department of Defense's physical security concept is to create a layered or "tiered" defensive system which consists of both active and passive perimeter barriers to delay intruders. The Department employs an ASTM International performance standard and testing procedure for both active entrance barriers and passive perimeter barriers designated as "vehicle-impact rated barriers," or "anti-ram barriers." The current standard is ASTM F , Standard Test Method for Vehicle Crash Testing of Perimeter Barriers. The ASTM F test standard rates barriers in twelve impact categories, with three predetermined impact velocities for each category and four potential penetration ratings for each impact rating. These penetration ratings are: P1 - < 3.3 ft; P to 23.0 ft; P to 98.4 ft; and P4 - > 98 ft. Of the four penetration ratings, barriers with a penetration rating of P4 will not be included in the DoD Anti-Ram Vehicle Barriers list. The following list of barriers includes active barriers for use at entrances, and passive or fixed barriers for other perimeter applications. This list will be updated quarterly in January, April, July and October. A request must be received one month prior to the list being published to be included on the next quarterly list. Note: This list supersedes all previous copies. Please refer to the date above to ensure you have the most up to date list. This list does not represent an overall endorsement of any product or design or address its operational suitability or maintainability. The list merely verifies that particular vehicle barriers have been certified in accordance with the performance standards in ASTM F , or previously tested to the U.S. Department of State SD -STD standard, and that the appropriate test reports have been submitted to, and validated by, the Protective Design Center. Each vehicle barrier system has its own distinct characteristics that must be considered and weighed against the needs and conditions of the individual installation. Some barrier characteristics are associated with vulnerabilities. These vulnerabilities may not be readily apparent to the end users. The PDC is available to discuss barrier characteristics, and any other barrier issues or questions. A few characteristics to consider are listed below: Impact speed at barrier (low speed impact): The use of some vehicle barriers presented in this list exhibit vulnerabilities when impacted at speeds other than those associated with the ASTM and DOS test impact velocities. Design Basis Threat (DBT) vehicle, other vehicle weights and speeds: The barriers presented in this list have been subjected to impacts under the specific conditions prescribed by the test designation. If the Installation s DBT includes vehicles significantly different than the test vehicle, performance of the system may differ from what may be expected. Deployment mechanisms: The mechanisms used to deploy vehicle barriers varies (pneumatic, hydraulic, electro-mechanical, manual). The various mechanisms should be investigated and the choice should be based on the best fit for the Installation. Environmental condition at barrier: Environmental conditions can vary greatly from location to location. Conditions such as rain, snow, ice, sand, gravel, hot, and cold need to be considered when selecting a barrier for a specific location. Operations and Maintenance (O&M) requirements: Each barrier comes with it s own operational and maintenance requirements. The O&M requirements vary in the amount and intensity from barrier to barrier. O&M needs to be figured into the overall life cycle cost of the barrier. After impact barrier gaps: Post impact gaps may be an inherent characteristic of the barrier system. The barrier system s post-impact condition should be carefully evaluated for it s capabilities in relation to defeat of the Installation s Design Basis Threat (DBT). Questions regarding the certification standard, barrier characteristics or this list can be sent to the Protective Design Center or at: [email protected]. Page 1 of 11
2 Barrier Type: Active Bollard K4 L3 RB80 Bollard American Anti-Ram Corporation 48" OC K4 L2 SP Defender K4 L2 DSC 800 Bollard Type Barricade M30 P1 K4 Shallow Mount Bollard FAAC International, Inc. Single bollard M30 P1 Elkosta M30 (K4) Perimeter Protection Germany GmbH Single bollard K8 L3 XT-1208-RB, Xact Series Retractable Ross Security Systems LLC Bollards - (fka-eagle Series Bollards, K8) hydraulic bollards K8 L1 ARMR B-30 Bollard Assembly, hydraulic bollards SP1000 Rising Bollard Gunnebo Competence Centre Outdoor single hydraulic bollard Gunnebo Bollard Perimeter Security single hydraulic bollard SP Titan K12 L2 XT-1200-RB, Xact Series Retractable Ross Security Systems LLC Bollards - (fka-eagle Series Bollards, K12), hydraulic bollards K12 L2 NBI Hydraulic Bollard Barrier HT1 Raptor Heald Ltd single bollard RSS4003 RSSI Page 2 of 11
3 Viper RBSM 1000 K13 L1 K12 Shallow Mount Bollard TITAN MKII Hydraulic Bollard B40 Retractable Bollard Heald Ltd. Calpipe Security Bollards Barrier Type: Active Drop-Arm Beam K4 K4 L3 L3 M30 P1 K4 K4 L2 L2 M30 P2 M30 P1 K8 L3 CRB-240 Drop Gate Bosik Bar VBS Shallow Foundation Barrier (SP VBB) K4 M foot Drop Arm Assembly IP500 Transportable Beam for Quick Deployment TT212EC Drop Arm Beam Barrier System Barrier Arm Crash Gate StrongArm M30 VPL-CB-24 VPL-CB-24 CRB-K12-2 Drop Arm Gate Barrier Bosik Bar VBS Deep Foundation Barrier (SP VBB) K12 American Anti Ram Apex Fabrication & Design, Inc. Logical Decisions HySecurity Gate, Inc. Autogate, Inc Autogate, Inc American Physical Security Group, Inc. Single wedge shaped bollard, hydraulic bollards, hydraulic bollards approx 11.5 foot clear opening 14 foot clear opening, surface mounted Approx 12.5 foot clear opening 14.5 foot clear opening 14.5 foot clear opening 12.9 foot clear opening foot clear opening Page 3 of 11
4 M50 P3 K12 L2 Drop Arm Vehicle Barrier - KBVB DSC 7000 Barrier NMSB XII Crash Beam Barrier - 12 ft NMSB XII Crash Beam Barrier - 18 ft StrongArm M50 HySecurity Gate, Inc. Barrier Type: Active Gate M30 P1 AR ft K4 L3 ARMR Model 730 Crash Gate K4 L2 ARMR Model 400 Sliding Gate CG12 Gate DSC 288 DSC 7500 Barrier Cable Restraint Barrier - 50 ft Cable Crash Gate AR 466 Anti-Ram Vehicle Barrier ft SR 466 Anti-Ram Vehicle Barrier Heavy Duty Gate, Inc. American Anti Ram Gibraltar Cable Barrier Systems, L.P. Gibraltar Cable Barrier Systems, L.P. Morrison Equipment Morrison Equipment 18 foot clear opening 20 foot clear opening 50 foot clear opening 24 foot clear opening 16.5 foot clear opening foot clear opening Page 4 of 11
5 AR 446 Anti-Ram Vehicle Barrier - 40 ft Morrison Equipment 40 foot clear opening K12 Cable Restraint Barrier - 50 ft NEU Security Systems 50 foot clear opening K12 Cable Restraint Barrier - 24 ft NEU Security Systems 24 foot clear opening Modified Interlocking Finger Gate Logical Decisions V shape, 13 foot clear opening K12 L1 ARMR Model 450 Anti-Climb High Security Vehicle Access Control Cantilever Gate System Barrier Type: Active Net M50 P3 M50 P3 M40 P1 30' Retractable Net Vehicle Barrier System 90' Retractable Net Vehicle Barrier System Retractable Cable Net Vehicle Barrier System - 20 ft Retractable Cable Net Vehicle Barrier System ft Modified Vehicle Arresting System (VAS) GRAB ft Engineered Arresting Systems Corporation Smith & Wesson Security Solutions (fka Universal Safety Response) 30 foot clear between stanchions - interpolation with 90 foot barrier is acceptable 90 foot clear between stanchions - interpolation with 30 foot barrier is acceptable 19' 9.5" clear opening between stanchions - interpolation with 52' 5" barrier is acceptable 52' 5" clear opening between stanchions - interpolation with 19' 9.5" barrier is acceptable 24 foot tested width - interpolation with 60 foot barrier is acceptable Page 5 of 11
6 M40 P2 GRAB ft GRAB ft GRAB ft Smith & Wesson Security Solutions (fka Universal Safety Response) 60 foot clear opening - interpolation with 12 foot barrier is acceptable wessonsecuritysolutions.com/ Smith & Wesson Security Solutions (fka Universal Safety Response) 14 foot net width - interpolation with 62 foot barrier is acceptable wessonsecuritysolutions.com/ Smith & Wesson Security Solutions (fka Universal Safety Response) 62 foot net width - interpolation with 14 foot barrier is acceptable wessonsecuritysolutions.com/ Barrier Type: Active Post and Beam Gunnebo Competence Centre Outdoor K12 L2 Barrier Lift System - K12 Perimeter Security 10 m width SP Patriot Barrier Type: Active Wedge M40 P3 DSC 1000 Barrier, portable wedge K4 L1 MP5000 Mobile Barrier, portable wedge DSC 1100 Quick Beam Deployment K4 L2, surface mounted Barrier System K4 L3 DSC 1200 Barrier XS-2000-PW, Xpress Series Portable Ross Security Systems LLC K4 L2 Wedge Barrier - (fka-osprey Series, portable wedge Portable Wedge) Page 6 of 11
7 DoD Anti-Ram Vehicle Barriers January 2013 K4 L1 M30 P3 M40 P3 M40 P3 M40 P3 ARMR Model 850 Portable/Towable Barrier MNSB XV Mobile Barrier MP5000 Mobile Barrier - 20 feet MNSB XVI Mobile Barrier NMSB XVX 20 ft Clear Opening Barrier American Anti Ram Shallow Mount Wedge Model SW12 Model DSC501 - Phalanx Type Barricade DSC 207S DSC 2000 Barrier XT-1000-W, Xact Series Wedge Barrier - Ross Security Systems LLC (fka-eagle Series Wedge Barrier) NSMB-IIID-E - 8 ft MSB II Barrier SHF3614S SecureUSA, Inc. SP Sentinel RSS-2000VI ARMR Shallow Mount Plate Barrier Model 820 RSSI Portable wedge, mobile wedge 20 foot clear opening, mobile wedge 16 foot clear opening, mobile wedge 20 foot clear opening, mobile wedge 8 foot plate 9 foot wide plate 9 foot wide plate 3-2 foot wedges with 18 inch spacing 9 foot wide plate 8 foot plate 14 foot wide plate 8 foot plate 6 post configuration - interpolation with 4 post configuration is acceptable, 5 post configuration acceptable 9 foot tested width Page 7 of 11
8 RSS ft Wedge Barrier HT1 Viper Model III D-E 10 Barrier System Model III D-E 11 Barrier System Model III D-E 12 Barrier System Model III D-E 14 Barrier System 16-ft Wedge System Road Blocker Model GBRH50 Wedge Barrier RSSI Smith & Wesson Security Solutions (fka Universal Safety Response) Heald Ltd. Smith & Wesson Security Solutions (fka Universal Safety Response) Guardian Industries Co. 4 post configuration - interpolation with 6 post configuration is acceptable, 5 post configuration acceptable 9 foot tested width 3 m tested width (~10 ft) 10 foot tested width 11 foot tested width 12 foot tested width 14 foot tested width 16 foot tested width 10' 1" tested width Barrier Type: Active Cable RSSI 4-1" diameter cables, 100' tested total M40 P2 RSSI Cable Trap System length Barrier Type: Passive Bollard DSC 650 Shallow Foundation Bollard PU50 P2 2-bollard array Array Page 8 of 11
9 K4 L3 SP1000 Static Shallow Mount Barrier M30 P1 M30 Shallow Foundation Modular Bollard System M30 P1 Set and Pour Bollard M30 P2 8" SM Removable K4 Shallow Mount Calpipe Security Bollards Bollard M40 P1 M40 Shallow Foundation Modular Bollard System M50 P3 FB-K12 Fixed Bollard System American Physical Security Group, Inc. Single Bollard Vehicle Barrier System K12 L2 DSC 600 Shallow Frame Bollard Array M50 P3 M50 Shallow Foundation Bollard - 40 Gibraltar Cable Barrier Systems, L.P. M50 Shallow Foundation Bollard Gibraltar Cable Barrier Systems, L.P. Model 6 Bollards - 4-bank Barrier Type: Passive Cable M30 P1 M40 P2 High Performance Post, Rail, and Structural Stand System - 73 ft (1" cable) Cable Trap System High Performance Post, Rail, and M40 P2 Structural Stand System - 73 ft (1.25" cable) Cable Crash Fence RSSI NEU Security Systems Single bollard single bollard 2-bollard array 4-bollard array, shallow mount 3-1" diameter cables, 72' tested length (post to post) 4-1 diameter cables, 96 tested length (end post to end post) " diameter cables, 72' tested length (post to post) 3 strand cable barrier Page 9 of 11
10 Cable Crash Fence M50/P1 Cable Barrier System High Performance Post, Rail, and Structural Stand System (1.5" cable) High Performance Post, Rail, and M50 P3 Structural Stand System - 41 ft (1.25" cable) M50 Post and Cable System Gibraltar Cable Barrier Systems, L.P. Smith & Wesson Security Solutions (fka Universal Safety Response) Barrier Type: Passive Fence K8 K8 K8 K8 L1 L2 L2 L2 K12 L2 Perimeter Security Fence with One-Inch Cable and Diagonal Perimeter Security Fence with 1 in Cable and Bollard Anchorage Ameristar Impasse Perimeter Security Fence Perimeter Security Fence with One-Inch Cable and Bollard Anchorage Ameristar High Performance Post, Rail, and Structural Strand System Impasse Security Fencing Perimeter Security Systems Fence Gibraltar Cable Crash Fence Gibraltar Cable Barrier Systems, L.P. tested length foot, end post to end post 3-1.5" diameter cables, 40' tested length (post to post) 3-1.5" diameter cables, 56' tested length (post to post) " diameter cables, 40' tested length (post to post) tested length - 50 foot, center of end post to center of end post 2-1" diameter cables, 162 foot tested length 2-1" diameter cables, 162 foot tested length 40 foot tested length end post to end post test length - 60 foot span, post to post Page 10 of 11
11 Barrier Type: Passive Inertial RDRW Mk. 4 Geocell Systems Inc. Earth filled barrier Expeditionary Earth Filled Barrier DefenCell Earth filled barrier Page 11 of 11
12
DEPARTMENT OF DEFENSE US ARMY CORPS OF ENGINEERS PROTECTIVE DESIGN CENTER 1616 Capitol Avenue, Suite 9000 OMAHA, NEBRASKA 68102-4901
DEPARTMENT OF DEFENSE US ARMY CORPS OF ENGINEERS PROTECTIVE DESIGN CENTER 1616 Capitol Avenue, Suite 9000 OMAHA, NEBRASKA 68102-4901 DOD ANTI-RAM VEHICLE BARRIER LIST List Date: January 2014 The Department
DS CERTIFIED ANTI-RAM VEHICLE BARRIERS Tuesday, April 29, 2008
U.S. DEPARTMENT OF STATE Tuesday, April 29, 2008 The Department of State s (DOS) physical security concept is to create a layered or tiered defensive system which consists of both active and passive perimeter
Product PHotoBook ACTIVE PASSIVE MOBILE ELECTRONIC MONITORING ACCESS CONTROL
Product PHotoBook ACTIVE PASSIVE MOBILE ELECTRONIC MONITORING ACCESS CONTROL Smith & Wesson Security Solutions Product photobook ACTIVE VEHICLE BARRIERS Ground Retractable Automobile Barrier (GRAB ).....
Security Solutions. The Perimeter Security and Vehicle Barrier Experts. www.futurenetsecurity.com. A FutureNet Group Company
Security Solutions The Perimeter Security and Vehicle Barrier Experts Quality Integrity Innovation Professionalism Service ACTIVE VEHICLE BARRIERS PASSIVE VEHICLE BARRIERS ELECTRONIC SECURITY ACCESS CONTROL
your total solution provider
PART OF Vehicle Access & Perimeter Protection Systems Hostile Vehicle Mitigation, Medium Security and Passive Vehicle Access Schemes APT Security Systems is part of the APT Controls Group of companies
Dams Sector. Active and Passive Vehicle Barriers Guide
Dams Sector Active and Passive Vehicle Barriers Guide 2010 Dams Sector Active and Passive Vehicle Barriers Guide Purpose The purpose of this guide is to assist dam owners and operators in understanding
The Tested and Proven Performance* of Security Grade Chain Link Fencing Systems
The Tested and Proven Performance* of Security Grade Chain Link Fencing Systems Deterring Delaying Protecting Published by the Chain Link Fence Manufacturers Institute (CLFMI) 10015 Old Columbia Road Suite
FRONTIER PITTS Datacentre Protection
FRONTIER PITTS Introduction Bespoke protection for Data and Cash Centres Frontier Pitts secure various Data Centres and Cash Centres in the UK and around the World, with a variety of equipment from both
Guide to Active Vehicle Barrier (AVB) Specification and Selection Resources
Guide to Active Vehicle Barrier (AVB) Specification and Selection Resources DISTRIBUTION STATEMENT: Approved for public release; distribution is unlimited. COPYRIGHT: The U.S. Government retains Unlimited
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational
FAAC International, Inc.
TEST REPORT FOR: FAAC International, Inc. J 355 HA M30 (K4) Bollard TESTED TO: ASTM F 2656-07 Standard Test Method for Vehicle Crash Testing of Perimeter Barriers Test M30 PREPARED FOR: FAAC International,
Chapter 3: Fall Protection/ Scaffolding Safety
Chapter 3: Fall Protection/ Scaffolding Safety Learning Objectives In this chapter you will learn to: recognize the hazards commonly associated with work on or around scaffolds; be aware of common scaffold-related
FALL PROTECTION PROGRAM
FALL PROTECTION PROGRAM Page 2 of 15 Table of Contents Applicability... 3 Overview... 3 Definitions... 3 Responsibilities... 5 Risk Assessment... 6 Risk Management... 7 Roof Access Procedure 10 Rescue
Load Testing and Lift Engineering
177 Load Testing and Lift Engineering In today s business climate, the importance of reliable, verifiable load testing cannot be overstated. When your lift weighs hundreds or thousands of tons and is worth
Linear Motion & Assembly Technologies - Guarding System
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Linear Motion & Assembly Technologies - Guarding System EcoSafe Guarding System from Rexroth Guarding
Minimizes sediment and debris from entering storm drains that lead to waterways and watercourses.
4.5-p DRAIN INLET PROTECTION Alternative Names: DI protection, Drop Inlet Protection DESCRIPTION Storm drain inlet (DI) protection slows and ponds stormwater, and filters sediment and debris before it
Fall Protection and Fall Prevention. San José State University Environmental Health and Safety Facilities Development & Operations
Fall Protection and Fall Prevention San José State University Environmental Health and Safety Facilities Development & Operations Learning Objectives To understand the hazards of falls To understand when
FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples
FOUNDATION DESIGN Proportioning elements for: Transfer of seismic forces Strength and stiffness Shallow and deep foundations Elastic and plastic analysis Foundation Design 14-1 Load Path and Transfer to
perimeter security design 4
perimeter security design 4 4.1 INTRODUCTION Perimeter security is designed to protect employees, visitors, and building functions and services from threats such as unauthorized vehicles approaching close
Fall Protection System: A system put in place to protect workers from falling. (i.e. installation of guardrails, fall arrest, fall restraint, etc.
SWP (6) FALL PROTECTION PROGRAM The following information on Fall Protection has been based around the BC OHS Regulations, standards, policies and guidelines. Prior to starting work outside of BC, the
Designed and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
DYWIDAG-SYSTEMS INTERNATIONAL. DYWIDAG Barrier Cable System. Glendale Galleria Parking Structure, Glendale, California
DYWIDA Barrier Cable System lendale alleria Parking Structure, lendale, California COMPONENTS AND STRAND PROPERTIES Barrier Cable System Components Monostrand Anchorage and Pocket Former Barrel & Wedge
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
Davit Systems and Outriggers
Safety From The Top Down Davit Systems and Outriggers Suspended Access Systems and Fall Protection Davits Overview Standards in the United States and Canada require a building to provide certified anchorages
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
INTRUSION ALARM SYSTEM
INTRUSION ALARM SYSTEM Case studies reveal most burglars are deterred by the mere presence of an alarm system. Burglars attack unprotected premises considerably more often than ones protected by alarm
Range Equipment HVAC Design & Supply Modular Ranges
Range Equipment HVAC Design & Supply Modular Ranges SRI Shooting Range Industries LLC, SRI is a premier design and manufacturing company of quality and innovative live fire Modular Containerized Small
Horizontal Cable Systems
Safety From The Top Down Suspended Access Systems and Fall Protection Overview Horizontal cable systems are generally installed as a permanent fall protection system, typically consisting of two terminating
PROGRAMMABLE DECELERATION DEVICES FOR AUTOMOTIVE TESTING
PROGRAMMABLE DECELERATON DEVCES FOR AUTOMOTVE TESTNG Hansjoerg Schinke, MESSRNG Automotive Service GmbH Robert Weber, Urich Fuehrer MESSRNG Systembau MSG GmbH Germany Paper Number: 98-S3-P-13 ABSTRACT
A U T O M O T I V E L I F T S
Q U A L I T Y Y O U E X P E C T AT A P R I C E Y O U W O U L D N T T H E S TA N D A R D I N I N F O R M AT I O N, E Q U I P M E N T A N D D I A G N O S T I C S S Y S T E M S h t t p : / / d i a g n o s
CALIFORNIA CODES HEALTH AND SAFETY CODE SECTION 115920-115929. 115920. This act shall be known and may be cited as the Swimming Pool Safety Act.
CALIFORNIA CODES HEALTH AND SAFETY CODE SECTION 115920-115929 115920. This act shall be known and may be cited as the Swimming Pool Safety Act. 115921. As used in this article the following terms have
LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
Wall-Mounting your HP computer. User Guide
Wall-Mounting your HP computer User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should
CH. 2 LOADS ON BUILDINGS
CH. 2 LOADS ON BUILDINGS GRAVITY LOADS Dead loads Vertical loads due to weight of building and any permanent equipment Dead loads of structural elements cannot be readily determined b/c weight depends
Walking and Working Surface Checklist:
Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
Security Barriers in the Physical Protection Concept of Nuclear Facilities In Switzerland
Security Barriers in the Physical Protection Concept of Nuclear Facilities In Switzerland B. Wieland Swiss Federal Office of Energy, CH 3003 Berne, Switzerland ABSTRACT: The presentation describes the
Miller Engineered Solutions Customized Fall Protection Solutions. NEW! Now featuring Rigid Rail Systems
Miller Engineered Solutions Customized Fall Protection Solutions NEW! Now featuring Rigid Rail Systems Custom systems for fall protection needs Vast network of trained and certified installer partners
Fall protection systems and practices Duty to have fall protection Protection at or above 6' level.
Duty to have fall protection Protection at or above 6' level. Walking/working surfaces inspected before work begins. Employees can only work on surfaces strong enough to support them. Page 1 Protection
SOME HELP WITH BRITISH STANDARD BS EN 1570:1999 Safety requirements for lifting tables
SOME HELP WITH BRITISH STANDARD BS EN 1570:1999 Safety requirements for lifting tables This is intended to help as a brief guide / overview through some selected parts of the current Scissor Lift Table
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
Engineers at Liftech designed the structure of the first container crane and have designed and reviewed thousands of container cranes since.
Engineers at Liftech designed the structure of the first container crane and have designed and reviewed thousands of container cranes since. Liftech is the structural review engineer of record for most
4.3.5 - Breakaway Walls
4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free
BRIO Modular scaffolding
BRIO Modular scaffolding // Versatile and multifunctional // Table of content Features Benefits Solutions Basic components 2 4 6 11 // Features BRIO Modular Scaffolding covers the different configurations
REPORT NUMBER: 100900226COQ-003 ORIGINAL ISSUE DATE: July 19, 2013
REPORT NUMBER: 100900226COQ-003 ORIGINAL ISSUE DATE: July 19, 2013 TEST REPORT EVALUATION CENTER INTERTEK TESTING SERVICES NA LTD. 1500 BRIGANTINE DRIVE COQUITLAM, BC V3K 7C1 CANADA RENDERED TO PHOENIX
BOROUGH OF OAKLAND COUNTY OF BERGEN STATE OF NEW JERSEY ORDINANCE 13-CODE-685
BOROUGH OF OAKLAND COUNTY OF BERGEN STATE OF NEW JERSEY ORDINANCE 13-CODE-685 AN ORDINANCE TO AMEND, SUPPLEMENT AND REVISE THE CODE OF THE BOROUGH OF OAKLAND, LAND USE, CHAPTER 59 ENTITLED LAND USE AND
Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
Heating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
KNOWLEDGE SECURE IN THE GATES FENCING BSI PAS 68 BLAST SCREENS LONG PERIMETER ANTI-PERSONNEL AUTOMATIC NUMBER PLATE RECOGNITION
SECURE IN THE KNOWLEDGE LONG PERIMETER ANTI-VEHICLE BSI PAS 68 PASSIVE POLES LIGHTING COLUMNS BLAST SCREENS ANTI-PERSONNEL FENCING TEMPORARY SOLUTIONS GATES AUTOMATIC NUMBER PLATE RECOGNITION DOORS A DIVISION
Beam Load Ratings. Tandem Flatbed Trailers. M-52 (52K - 48 Tandem) 52,000# - 4 span 55,000# - 10 span 60,000# - 20 span 90,000# - 48 span
Flatbed Trailers Tandem Flatbed Trailers When quality workmanship, dependability and longevity are critical to your business, all coupled with the best manufacturer s backing in the industry, owner-operators
Division 2 Section 32 14 13.19 Section 02795
Note: The text must be edited to suit specific project requirements. It should be reviewed by a qualified civil or geotechnical engineer, or landscape architect familiar with the site conditions. Edit
Chain Link Fence Manufacturers Institute Security Fencing Recommendations
Chain Link Fence Manufacturers Institute Security Fencing Recommendations Chain link fencing has been the product of choice for security fencing for over 60 years because of its strength, corrosion resistance,
load on the soil. For this article s examples, load bearing values given by the following table will be assumed.
How Many Piers? By Gary Collins, P.E. A clear-cut guide to helical pier spacing Introduction Helical pier spacing is not an exact science. How many does it take to support a structure adequately or repair
Storage Solutions. Maximize Storage & Optimize Space
Storage Solutions Maximize Storage & Optimize Space Your Files Are Important With the cost and availability of office space at a premium, space utilization is key. An end-tab color-coded filing system
Working at Heights and Fall Protection
Standard Operating Procedures Working at Heights and Fall Protection Last Modified: JAN 2013 1 of 6 Working at Heights and Fall Protection I Purpose Serious accidents can result from falls. All employees
A Proven Barrier System Tested and Installed Worldwide
ANTI TERRORIST BOAT BARRIER SYSTEM A Proven Barrier System Tested and Installed Worldwide Pneumatic Barrier System, designed and supplied to withstand 1,000,000 ft-lbs of Kinetic energy which represents
What is the most obvious difference between pipe flow and open channel flow????????????? (in terms of flow conditions and energy situation)
OPEN CHANNEL FLOW 1 3 Question What is the most obvious difference between pipe flow and open channel flow????????????? (in terms of flow conditions and energy situation) Typical open channel shapes Figure
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
Site Development Information Worksheet for single family residential development
Site Development Information Worksheet for single family residential development Project description: Address: Owner Name: Phone No. Date Signature & phone number of Individual who Completed this Worksheet
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall
PERFORMANCE TEST REPORT Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall Report No.: Test Dates: 04/17/12 Through: 04/18/12 Report Date: 06/13/12 130 Derry Court
MERCHANTS METALS SECTION 32 31 13 ARMORLINK ALUMINIZED CHAIN LINK FENCE AND GATES 2014!
MERCHANTS METALS SECTION 32 31 13 ARMORLINK ALUMINIZED CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance
CITY UTILITIES DESIGN STANDARDS MANUAL
CITY UTILITIES DESIGN STANDARDS MANUAL Book 2 (SW) SW9 June 2015 SW9.01 Purpose This Chapter provides information for the design of open channels for the conveyance of stormwater in the City of Fort Wayne.
C. Remove all existing asphalt shingles, underlayment and any loose debris into contractor provided dumpsters.
SCOPE OF WORK Project Title: Replace Deteriorated Roof Singles at Cape Lookout National Seashore Maintenance Shop PMIS # 159350 Prepared By: Mike Baker Cape Lookout National Seashore 131Charles St Harkers
Roof Condition Analysis
Roof Condition Analysis Prepared for: J.W. Nelson John Evans Middle School - Gym Dome 2900 15th Avenue Greeley, Colorado Prepared by: Gregory Ham Coastal Specified Products 5252 Sherman Street Denver,
Solutions for your. Perimeter Security. Solutions for your. Permiter Security
Solutions for your Perimeter Security Solutions for your Permiter Security Melbourne Sydney Brisbane Perth Phone: 1300 364 864 www.magneticautomation.com.au Magnetic Automation Pty Magnetic Automation
Computer Support Tools category overview
Computer Support Tools category overview 2 Tech savvy. Computers are a big part of our daily work lives. And it seems as though every time we turn around they re evolving. Devices are getting smaller and
Group TRAFFIC MANAGEMENT SPECIALIST ACCESS WAY SOLUTIONS CREATIVE SOLUTIONS TO COMMON CHALLENGES. Products
Group Incorporating: Egmont Doors & totaldoors SPECIALIST ACCESS WAY SOLUTIONS TRAFFIC MANAGEMENT CREATIVE SOLUTIONS TO COMMON CHALLENGES 0800 807 753 [email protected] www.ultigroup.co.nz
HOSE & CABLE PROTECTION
HOSE & CALE PROTECTION Product Page AccessTrak, TrukTrak and TredTrak 2-5 FloorTrak 6 CableTrak Modular Carrier Track 7-9 Page 2 HOSE and CaLE PrOTECTION Features and enefits The AccessTrak ramping system
Intexma Graphics (Pty) Ltd
Intexma Graphics (Pty) Ltd Distributors for the complete supply of signage materials comprising of single and double roll up stands, banner walls, point of sale tables, signage boards and light boxes.
FALL PROTECTION WORK PLAN
FALL PROTECTION WORK PLAN INSTRUCTIONS A written fall protection work plan must be implemented by each employer on a job site where a fall hazard of 10 feet or greater exists, in accordance with OSHA Standards.
Perimeter. 14ft. 5ft. 11ft.
Perimeter The perimeter of a geometric figure is the distance around the figure. The perimeter could be thought of as walking around the figure while keeping track of the distance traveled. To determine
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
PICP Construction. Why PICPs The Big Picture. Key things to know about PICPs
PICP Construction Permeable Interlocking Concrete Pavement Presenter: Frank Gandora, President Creative Hardscape Why PICPs The Big Picture Germany was first to develop PICPs 2005 Clean Water Act Federal
SECURITY VS. EXITING... Door Locking Hardware in Schools DIVISION OF THE STATE ARCHITECT
SECURITY VS. EXITING... Door Locking Hardware in Schools DIVISION OF THE STATE ARCHITECT G U I D E L I N E S DSA Guidelines for Door Locking Hardware in Schools Egress doors shall be readily openable from
Solving Geometric Applications
1.8 Solving Geometric Applications 1.8 OBJECTIVES 1. Find a perimeter 2. Solve applications that involve perimeter 3. Find the area of a rectangular figure 4. Apply area formulas 5. Apply volume formulas
MULTI-PURPOSE TEMPORARY BUILDINGS
Accommodation Structures Clear Span Structures Emergency Shelters Emergency Storage Solutions Industrial Storage Solutions Modular Buildings Prefabricated Buildings Relocatable Structures / Buildings Temporary
PLM series Permanent load lifting magnets
Lifting gear Load lifting magnets/chain hoists PLM series Permanent load lifting magnets Load-bearing capacity of up to 1 t depending on model despite light weight High standard of safety with simple lever
Open Channel Diffusers
Open Channel Diffusers Application Information: Open channel diffusers are used to increase mixing and absorbance efficiency of a chemical solution into the process water. Specifically designed penetrations
TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana
Architectural Testing TEST REPORT Report No.: D0162.02-201-44 Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana PRODUCT TYPE: Pressure Equalized Rainscreen SERIES/MODEL: 4 mm Composite
Creative Event Equipment. The inflatable Event Tent
Creative Event Equipment The inflatable Event Tent US 2013 X-GLOO Event Equipment X-GLOO inflatable event tents and seatings are distinguished by innovative high-tech construction and functionality according
GATES, CATTLEGUARDS and PASSAGEWAYS. This factsheet looks at various options for allowing passage through fences for livestock, wildlife and people.
Fencing Order No. 307.400-1 Agdex: 724 March 1996 GATES, CATTLEGUARDS and PASSAGEWAYS This factsheet looks at various options for allowing passage through fences for livestock, wildlife and people. GENERAL
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT
ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT Description: This work shall consist of furnishing all materials, equipment and labor necessary for conducting an Osterberg Cell (O-Cell) Load
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO
SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)
SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795) Note: This guide specification for U.S. applications describes construction of permeable interlocking concrete
SECTION 32 31 13 CHAIN LINK FENCES AND GATES
PART 1 GENERAL 1.1 DESCRIPTION SECTION 32 31 13 CHAIN LINK FENCES AND GATES SPEC WRITER NOTES: 1. Delete or add information between //---// and any other items applicable to project. Cover any item added
Storm Drain Inlet Protection - IP
Storm Drain Inlet Protection - IP DEFINITION A temporary protective device formed around a storm drain drop inlet to trap sediment. PURPOSE To prevent sediment from entering storm drainage systems, prior
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
