DYWIDAG-SYSTEMS INTERNATIONAL. DYWIDAG Barrier Cable System. Glendale Galleria Parking Structure, Glendale, California
|
|
|
- Alicia Arnold
- 10 years ago
- Views:
Transcription
1 DYWIDA Barrier Cable System lendale alleria Parking Structure, lendale, California
2 COMPONENTS AND STRAND PROPERTIES Barrier Cable System Components Monostrand Anchorage and Pocket Former Barrel & Wedge Monostrand Anchorage and Pocket Former Adjustable Anchor (RAB-IT ) (A) (B) (A) Barrel and Wedge Anchor (B) With End Cap Adjustable Anchor RAB-IT Mechanical Properties of Strand for Barrier Cable STEEL NOMINAL ULTIMATE ULTIMATE NOMINAL NOMINAL RADE DIAMETER STRENTH ELONATION AREA WEIHT in mm Ibs kn % sq. in sq mm # per 1000 ft kg/1000m 250/1725 3/ /1860* 1/ /1725 1/ /1585 1/ /1345 1/ *Non galvanized all other steel grades are galvanized
3 DYWIDA BARRIER CABLE SYSTEM J Key A Barrel Anchors with End Caps K E F B C D Intermediate Tube Embedded Anchors End Angle with Barrel Anchors and End Caps D B C E F H Intermediate Angle (illustration) or Channel (photo E) End Angle with Angle Caps End Tube with Barrel Anchors Embedded Intermediate Sleeve A I Detail with Monostrand Anchorages for Inaccessible End Conditions J Monostrand Achorage and Pocket Former I K Intermediate Spreader Plate with U-Bolt H NOTE: RAB-IT anchors may be used as alternate anchorage at end conditions
4 APPLICATIONS A B C F E D. K I H
5 DYWIDA Barrier Cable System Prestressed strands are an increasingly popular option in the selection of vehicular and pedestrian barrier systems. The DYWIDA Barrier Cable system has two particular advantages over other systems available on the market: it is economic in its high strength to weight ratio; and it resists impact in tension, which is more efficient than the bending mode of other systems. DSI can provide complete service including: SELECTION OF CORROSION PROTECTION DESIN AND DETAILIN OF ANCHORAES SUPPLY AND INSTALLATION OF COMPLETE BARRIER SYSTEM Code Compliance Building codes provide very few guidelines for the design and installation of barrier cable systems. The PTI Specification For Seven Wire Steel Strand Barrier Cable Applications has adopted the criteria given in the Uniform Building Code, which prescribes a specific lateral load resistance at a fixed distance from the floor level for vehicular restraint, as well as minimum cable spacing for pedestrian protection. Additional information on the design of barrier cable systems is available from your local DSI representative. As well as meeting PTI specifications, the DYWIDA wedge-anchor system when properly installed exceeds ACI code requirements for guaranteed ultimate capacity of the strand. Anchorage Components The anchorage system selected for the barrier cable is the most critical element in the overall performance and safety of the barrier cable system. DSI offers a wide range of embedded and external connection components to meet a wide variety of architectural and support conditions. To assure that anchorages develop the required capacity, backstressing is required for every cable anchorage. Though the cables are pretensioned to a relatively small force, anchorages will experience the full cable tension during impact. If the cables are properly installed the connection of the barrier system to the column or shear wall is the connection that will ultimately resist the impact, not the cable anchorages or cables themselves. Service and Technical Assistance DYWIDA barrier cables are cut to length and shipped together with all required accessories and attachments or shipped on wooden spools for site fabrication. Field technicians are available to assist contractors in placing and stressing DSI supplied barrier cables. DSI also has trained and experienced field crews available to perform a complete system installation in accordance with the project specifications. Installation is quick, especially when performed by DSI experienced crews. Stressing Corrosion Protection DSI can assist in the selection of appropriate corrosion protection measures according to your project location. DSI can supply barrier cable with various protection options: alvanized coating conforming to ASTM A475 Polyethylene coating in various colors Epoxy coating conforming to ASTM A882* Anchorage components may be protected through hot dip galvanizing (ASTM A153) or zinc plating conforming to ASTM B633. Unstressed Barrier Cables Unstressed Barrier Cables Back Stressing Hydraulic Jack (Stress to Force Required By Design) Temporary Slotted Steel Plate MAKE USE OF DSI EXPERIENCE CALL DSI QUALITY INSTALLATION *Cannot be backstressed without damage to coating
6 Shear Studs Shearwall/inaccessible column embeddment. Cables Monostrand anchorages for embeddment reserving pocket formers. Mechanical Anchors Surface mounted end angle with barrel anchors. Backstressing of barrier cable. For sales and service contact the DSI office nearest you.
7 DYWIDA-Systems International USA Inc. 320 Marmon Drive Bolingbrook, il Phone (630) Fax (630) Newark Road Toughkenamon, PA Phone (610) Fax (610) S. Central Ave Unit I Kent, WA Phone (253) Fax (253) South Street Long Beach, CA Phone (562) Fax (562) Stone Drive Tucker, A Phone (770) Fax (770) N. Peyco Drive Arlington, tx Phone (817) Fax (817) sw 50th Avenue Davie, FL Phone (954) Fax (954) Ann Road Long Valley, NJ Phone (908) Fax (908) Please note: This brochure serves basic information purposes only. Technical data and information provided herein shall be considered non-binding and may be subject to change without notice. We do not assume any liability for losses or damages attributed to the use of this technical data and any improper use of our products. Should you require further information on particular products, please do not hesitate to contact us. DYWIDA-Systems International Canada Ltd. Civil Business Unit Western Branch th Avenue, Suite 103 Surrey, BC V4N 4C4 Canada Phone (604) Fax (604) [email protected] Eastern Branch 37 Cardico Drive ormley, on L0H 10 Canada Phone (905) Fax (905) [email protected] Calgary Office Street N.E., Suite 204 Calgary, Alberta T2E 6 Z2 Canada Phone (403) Fax (403) [email protected] Quebec Office St. Bruno, Quebec J3V 6E2 Canada Phone (450) Fax (450) [email protected] A r g e n t i n a A u s t r a l i a A u s t r i a b e l g i u m B o s n i a a n d h e r z e g o v i n a B r a z i l C a n a d a C h i l e C h i n A C o l o m b i a C o s t a R i C A C r o a t i a C z e c h r e p u b l i c D e n m a r k E g y p t e s t o n i a F i n l a n d F r a n c e e r m a n y r e e c e g u A t e m A L A h o n d u r A S H o n g K o n g I n d o n e s i a I r a n I t a l y J a p a n K o r e a L e b a n o n L u x e m b o u r g m A l a y s i a M e x i c o N e t h e r l a n d s N o r w a y O m a n p A n a m a p A r a g u a y P e r u p o l A n d P o r t u g a l Q a t a r r u s s i A s A u d i A r a b i a s i n g a p o r e S o u t h A f r i C A S p a i n S w e d e n S w i t z e r l a n d t A i w a n T h a i l a n d T u r k e y U n i t e d A r a b E m i r a t e s U n i t e d k i n g d o m U r u g u a y u s A V e n e z u e l a
References. DYWIDAG Tie Rods for Military Wharf in Guam
DYWIDAG Tie Rods References DYWIDAG Tie Rods for Military Wharf in Guam i Owner US Navy, Naval Base Guam, USA +++ General Contractor Black Construction Corporation, Guam, USA +++ Architect-Engineer Wilson
DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS
8601 North Black Canyon Highway Suite 103 Phoenix, AZ 8501 For Professionals Engaged in Post-Tensioning Design Issue 14 December 004 DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS by James D. Rogers 1 1.0
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
A Simple Method of Gripping Prestressing Strands for Tension Tests
A Simple Method of Gripping Prestressing Strands for Tension Tests Presents a simple technique for gripping a prestressing strand to measure its breaking strength, modulus of elasticity or stress-strain
TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE
SECTION 2.2 PAGE 1 / 9 l DESCRIPTION UCAN TZ torque controlled mechanical expansion wedge anchors have a Category 1 classification. They are used to resist static, wind and seismic tension and shear loads
DYWIDAG Circular Structure Repair with Hoop Tendons
DYWIDAG Circular Structure Repair with Hoop Tendons Contents Services for Repair of Circular Structures...4 Material for Repair of Circular Structures...5 Radial Force Distribution from Hoop Tendons...6
Cable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
Detailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
Prestressed Storage Tanks
Prestressed Storage Tanks Mike Harper Regional Manager [email protected] / 714 767 1313 Kevin Peacock Regional Manager [email protected] / 949 698 2740 DN Tanks overview Construction Procedures
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO
TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For:
TEST REPORT Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PRODUCT: Gorilla Column PVC Porch Post System with PVC Base / Cap Plates, PVC Bushings and 2-3/8 in Diameter and 3-1/2 in Diameter Galvanized
Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING 2004. Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim.
CHAPTER REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition Fifth Edition PRESTRESSED CONCRETE A. J. Clark School of Engineering Department of Civil and Environmental
Fall Protection System: A system put in place to protect workers from falling. (i.e. installation of guardrails, fall arrest, fall restraint, etc.
SWP (6) FALL PROTECTION PROGRAM The following information on Fall Protection has been based around the BC OHS Regulations, standards, policies and guidelines. Prior to starting work outside of BC, the
Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com
Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,
Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14
Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318
GUARDRAIL POST STEEL
GUARDRAIL POST STEEL Guardrail posts meeting materials certification are evaluated and checked for: 1. Dimensional acceptance 2. Physical test results a. Chemical b. Physical 3. Galvanized or painted coating
Embedded Parts Introduction - Anchors
In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical
PivotLoc Ladder Systems
N25 ACCESS AND SAFETY EQUIPMENT SPECIFICATION CLAUSES PivotLoc Ladder Systems To be read with The Main Contract Preliminaries, General Conditions, Sub-Contract Preliminaries. MINIMUM CONTRACTOR STANDARD
LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
High Capacity Helical Piles Limited Access Projects
High Capacity Helical Piles Limited Access Projects Tel 403 228-1767 Canada, USA, Russia Brendan ODonoghue 519 830-6113 Presentation Summary 1. Helical piles Background on large diameter shafts and helices
University of Missouri Hospitals and Clinics. Structural Repair and Protection of Post-tensioned Parking Garage
University of Missouri Hospitals and Clinics Structural Repair and Protection of Post-tensioned Parking Garage 1 University of Missouri Project The University of Missouri Health Care Patient and Visitor
Includes specifications for: Surface Cleaning & Mounting Hardware.
Three-Part Specifications - Copyright 2014 - Nixalite of America Inc Bird Screen Welded Wire Mesh Barriers Includes specifications for: Surface Cleaning & Mounting Hardware. Nixalite offers full rolls
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
Guidelines for the Design of Post-Tensioned Floors
Guidelines for the Design of Post-Tensioned Floors BY BIJAN O. AALAMI AND JENNIFER D. JURGENS his article presents a set of guidelines intended to T assist designers in routine post-tensioning design,
Discipline: Structural Issued 04-26-06
California Department of General Services. Division of the State Architect. Product Acceptance Report STRUCTURAL SHEAR PANEL SURE-BOARD SERIES 200 PANELS PA-132 Discipline: Structural Issued 04-26-06 This
SECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
SCAFFOLDING PRODUCT TECHNICAL GUIDE. Scaffold Couplers General Technical and Application Manual. Genuine Safety. Outstanding Service.
SCAFFOLDING PRODUCT TECHNICAL GUIDE Scaffold Couplers Genuine Safety. Outstanding Service. Introduction Scaffold couplers are essentially the fundamental component that is used to assemble tube-and-coupler
Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.
P-5 The P-5 is hot forged from carbon steel. The formed head provis spherical seating that the Lifting Eye engages, while a disc-shaped foot is embedd in the concrete. Due to its being a forged part, the
HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance
HUS-V Screw anchor Anchor version HUS-V 8 / 10 Carbon steel concrete screw with hexagonal head Benefits - High productivity less drilling and fewer operations than with conventional anchors - Technical
COMPETENCY ANALYSIS PROFILE. Rodworker 452A. (All unshaded skill sets must be demonstrated/ completed) Lift equipment and materials
COMPETENCY ANALYSIS PROFILE Rodworker 452A (All unshaded skill sets must be demonstrated/ completed) PROTECT SELF AND OTHERS Wear personal protective (PPE) Lift and Apply housekeeping rules Interpret warning
PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE
FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances
Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...
Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information
Green Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
ALL THREAD ROD Price Sheet ATR-6.16 Effective: June 13, 2016 Cancels Price Sheet ATR-5.14 of May 12, 2014
ALL THREAD ROD Price Sheet ATR-6.16 Effective: June 13, 2016 Cancels Price Sheet ATR-5.14 of May 12, 2014 FOR THE MOST CURRENT PRODUCT / PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT OUR WEBSITE
DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,
DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared
TARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
HIGH TENSION CABLE BARRIER
Special Provision September 11, 2006 SECTION 02845 S HIGH TENSION CABLE BARRIER PART 1 GENERAL 1.1 SECTION INCLUDES A. Cable barrier materials and installation procedures. 1.2 RELATED SECTIONS A. Section
Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps
Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning May 7th 2013: Dominique Deschamps Scope of the paper Presentation of the project Cause of cracks
June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL
7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction
One-third of all fatalities in the U.S. construction
Guardrail systems: Fall prevention for floor and wall openings and open-sided floors One-third of all fatalities in the U.S. construction industry result from falls from elevations. Falls from elevations
SECTION 02845 GUARDRAILS
SECTION 02845 GUARDRAILS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals necessary and repair, replace or install all types of guardrails as specified herein
PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems
PERFORMANCE TEST REPORT Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems Summary of Results Title Test Specimen #1 Test Specimen #2 Air Infiltration
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
IPR-02-64. Äspö Hard Rock Laboratory. International Progress Report. Temperature Buffer Test. Report for retaining plug and anchoring
International Progress Report IPR-02-64 Äspö Hard Rock Laboratory Temperature Buffer Test Report for retaining plug and anchoring Richard Bäck Äspö HRL September 2002 Svensk Kärnbränslehantering AB Swedish
2. Division 05 Structural Steel Framing for steel framework requirements
SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division
New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations
from New construction foundations don t have to be a headache. The CHANCE Helical Pier Foundation System gives you the performance of concrete without the drawbacks and liabilities of driven piles and
Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor
Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor Supplement to Hilti North American Product Technical Guide Volume 2: Anchor Fastening Technical Guide 2011 Edition 3.3. KWIK
TEST REPORT. Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing
TEST REPORT Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing Report No.: Report Date: 01/28/14 Test Record Retention Date: 12/20/17 130 Derry
The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma
The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma Bart B. Barrett, B.S., P.E.1 Kerry S. Lee, M.B.A., P.E., M. ASCE2 Erik L. Nelson, Ph.D., P.E., M. ASCE3
SECTION 03400 PRECAST CONCRETE STRUCTURES
SECTION 03400 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for precast concrete structures, including fabrication and erection. 1.02 REFERENCE STANDARDS A. American Society for
OVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.
Pick Smarter. Pick Better. Pick UNEX. Skatewheel (SW) Skatewheel Gravity Conveyor is ideally suited to convey lightweight packages and where operations require portable or temporary conveyor lines such
Fence SpecCheck Wheatland Tube Company 800 343 0124
Fence SpecCheck Wheatland Tube Company 800 343 0124 www.wheatland.com ASTM Specifications (May 2014) www.astm.org A53/A53M-12 Schedule 40 & 80 Pipe: Specification for Pipe, Steel, Black and Hot- Dipped,
HVU with HAS/HAS-E rod adhesive anchor
HVU with HAS/HAS-E rod HVU with HAS/HAS-E rod adhesive anchor Mortar system Benefits Hilti HVU foil capsule HAS HAS-R HAS-HCR rod - suitable for non-cracked concrete C 20/25 to C 50/60 - high loading capacity
MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE
MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural mezzanine design. In addition, it is to serve as
Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12)
Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12) Design Criteria AASHTO LRFD Bridge Design Specifications, 6th Edition; Structures Detailing Manual (SDM); Structures Design Guidelines (SDG)
DESIGN CLARIFICATION (DC)
DESIGN CLARIFICATION (DC) Owner: Victor Valley Wastewater Reclamation Authority Date: 03/03/2015 Contractor: W M Lyles Carollo Project No.: 8299A.20 Project Name: Subregional WRPs DC No.: 001 DC Title:
Magnesium TM. Soil Anodes. High Potential Magnesium. Production - Quality Control. Laboratory- Testing. Packaging- Availability
Magnesium TM Soil Anodes High Potential Magnesium SuperMag High Potential Magnesium Anodes from Galvotec Alloys, Inc. offers typical high workingldriving potentials of -1.70 volts or better vs. copperlcopper
Using Williams Products
Using Williams Products Readers of this catalog should independently verify the efficiency of any Williams products for the purpose intended by the user. The suitability of Williams products will depend
Evaluation Report CCMC 13102-R Pieux Vissés Vistech / Postech Screw Piles
Evaluation Report CCMC 13102-R Pieux Vissés Vistech / Postech Screw Piles 1. Opinion 1of 6 MASTERFORMAT: 31 62 16.01 Evaluation issued: 2003-02-13 Re-evaluated: 2015-03-13 Re-evaluation due: 2018-02-13
TEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40
TEST REPORT Rendered to: INTEX MILLWORK SOLUTIONS, LLC For: Rigid Cellular PVC Guardrail System Hampton RS40 Report No: Report Date: 07/26/13 130 Derry Court York, PA 17406-8405 phone: 717-764-7700 fax:
MAINTENANCE AND INSPECTION OF BRIDGE STAY CABLE SYSTEMS
MAINTENANCE AND INSPECTION OF BRIDGE STAY CABLE SYSTEMS Workshop on Wind-Induced Vibrations St. Louis, Missouri April, 2006 By Habib Tabatabai University of Wisconsin-Milwaukee Introduction This work is
SECTION 11014 WINDOW WASHING SYSTEMS
SECTION 11014 WINDOW WASHING SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes, but is not limited to, design and furnishing portable davits, davit sleeves, dvit bases, four (4) removable outriggers,
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
PCI BIG BEAM COMPETITION
PCI BIG BEAM COMPETITION Official Rules for the PCI Engineering Design Competition Academic Year 2015-16 PROGRAM The PCI Student Education Committee is inviting entries from students to participate in
Chapter 5 Bridge Deck Slabs. Bridge Engineering 1
Chapter 5 Bridge Deck Slabs Bridge Engineering 1 Basic types of bridge decks In-situ reinforced concrete deck- (most common type) Pre-cast concrete deck (minimize the use of local labor) Open steel grid
DENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
1.02 SYSTEM DESCRIPTION
1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall
1.2 Advantages and Types of Prestressing
1.2 Advantages and Types of Prestressing This section covers the following topics. Definitions Advantages of Prestressing Limitations of Prestressing Types of Prestressing 1.2.1 Definitions The terms commonly
TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
COLORADO MODEL. 35 x 65 SPECIFICATIONS
COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square
Requirements for the Use of PRESSS Moment-Resisting Frame Systems
Requirements for the Use of PRESSS Moment-Resisting Frame Systems Neil M. Hawkins, Ph.D. Professor Emeritus Department of Civil Engineering University of Illinois at Urbana-Champaign Urbana, Illinois S.
EPOCH DESIGN. retail LOCKING SECURITY MAILBOXES U.S. POSTMASTER APPROVED STOP MAIL IDENTITY THEFT. value. quality. secure
MAIL BOSS LOCKING SECURITY MAILBOXES U.S. POSTMASTER APPROVED EPOCH DESIGN retail STOP MAIL IDENTITY THEFT value quality secure patented profits EPOCH DESIGN, LLC Mail Boss by Epoch Design, LLC offers
The following sketches show the plans of the two cases of one-way slabs. The spanning direction in each case is shown by the double headed arrow.
9.2 One-way Slabs This section covers the following topics. Introduction Analysis and Design 9.2.1 Introduction Slabs are an important structural component where prestressing is applied. With increase
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Hilti HIT-V and HAS Threaded Rod and Hilti HIT-Z Anchor Rod
, Monday, HAS March and HIT-Z 24, 2014 Hilti Rod Specifications and Technical Data Hilti and HAS Threaded Rod and Hilti HIT-Z Rod Specifications and Technical Data Hilti has provided threaded rod for many
Veneer Anchors. Masonry Veneer Anchors. Description. Applications
Veneer Anchors Description Dur-O-Wal manufactures and markets a large variety of veneer anchor assemblies designed and engineered to anchor brick, tile, stone or CMU veneer to a wood stud, metal stud,
Industrial Ringdown/Autodialer Telephone SCR Series
Industrial Communications Worldwide Industrial Ringdown/Autodialer Telephone Installation & Operation SCR 11 SCR 41 P005603 Rev. A 060612 5/28/2007 3:58 PM 7552-10th Street N.E. Calgary, Alberta, Canada
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1
Designation: F 668 07 Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1 This standard is issued under the fixed designation F 668; the
Reticulation sewers in basements Technical guidelines
Reticulation sewers in basements Technical guidelines Overview What These guidelines explain our technical requirements for laying sewers in building basements. The scope of the guide is restricted to
Wisconsin Building Products Evaluation
Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation
American National Standard For Electrical Rigid Steel Conduit (ERSC)
Revision of ANSI C80.1-1994 American National Standard For Electrical Rigid Steel Conduit (ERSC) Secretariat: Approved August 18, 2005 American National Standards Institute, Inc. NOTICE AND DISCLAIMER
CABLE TRENCH INSTALLATION GUIDE
1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL INFORMATION 4.0 PLANNING INFORMATION 5.0 CREW INFORMATION 6.0 CONTRACTOR INFORMATION 7.0 PRECASTED/ POURED-IN-PLACE TRENCH DRAWINGS 2.0 PURPOSE This standard
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
San Francisco Oakland Bay Bridge East Span Seismic Safety Project
San Francisco Oakland Bay Bridge East Span Seismic Safety Project Presented To: Society of American Military Engineers May 16, 2013 Brian Maroney, P.E. Dr. Engr. Karen Wang, P.E. Pier E9 Following the
Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996
CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
Seismic Technical Guide
Technical Document Seismic Technical Guide Hanger Wire Attachment Code Requirements 1 The International Building Code (IBC) defines the requirement for hanger wire and their supports and attachment methods.
HUS-HR, CR Screw anchor, stainless steel
HUS-HR, CR Screw anchor, Anchor version HUS-HR 6 / 8 / 10 / 14 Stainless steel concrete Screw with hexagonal head HUS-CR 10 Stainless steel concrete screw with countersunk head Benefits - High productivity
Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
Ver. 2. Guide to. Inspecting Residential Brick Veneer
Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan
TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION
TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006
[BARLINES MANUAL OF STANDARD PRACTICE (PHILS)] Chapter One METRIC (SI), PNS BAR SIZES STANDARDS AND OTHER CRITERION
Chapter One METRIC (SI), PNS BAR SIZES STANDARDS AND OTHER CRITERION By Amadeus (Mady) Magpile, President and CEO INTRODUCTION This is first in a series of articles outlining the Manual of Standard Practice,
HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs
HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast Anchor version HUS-A 6 Screw with hex head HUS-H 6 Screw with hex head HUS-I 6 Screw with hex head Benefits - Quick and easy setting - Low