1 L2 / L3 Switches Remote Network Monitoring (RMON) Configuration Guide Revision 1.0
2 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at Super Micro Computer, Inc. ( Supermicro ) reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent. IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product. FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense. California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. Perchlorate Material-special handling may apply. See for further details. Manual Revision 1.0 Release Date: October 28, 2013 Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders. Copyright 2013 by Super Micro Computer, Inc. All rights reserved. Printed in the United States of America Supermicro L2/L3 Switches Configuration Guide 2
3 Contents 1 RMON Configuration Guide RMON Overview RMON Groups Alarm group Event Group Statistics RMON Configuration Default Configuration Enabling RMON Configuring Alarms and Events Configuring Statistics RMON Configuration Example Supermicro L2/L3 Switches Configuration Guide 3
4 1 RMON Configuration Guide This document describes the system features supported in Supermicro Layer 2 / Layer 3 switch products. This document covers the system configurations for the below listed Supermicro switch products. Top of Rack Switches SSE-G24-TG4 SSE-G48-TG4 SSE-X24S SSE-X3348S SSE-X3348T Blade Switches SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM The majority of this document applies to the above listed Supermicro switch products. In any particular subsection however, the contents might vary across these product models. In those sections, the differences are clearly identified with reference to a particular model(s). If any particular model is not referenced, the reader can safely assume that the content is applicable to all the above listed models. Throughout this document, the common term switch refers to any of the above listed Supermicro switch models unless a particular model is noted. 1.1 RMON Overview Remote monitoring (RMON) is a method similar to Simple Network Management Protocol (SNMP) and uses a client-server model to monitor/manage remote devices on a network. RMON and SNMP differ in the approach used: RMON is used for "flow-based" monitoring, while SNMP is often used for "device-based" management. The data collected in RMON deals mainly with traffic patterns rather than the status of individual devices as in SNMP. Supermicro L2/L3 Switches Configuration Guide 4
5 RMON is implemented based on SNMP. RMON sends traps to the management device to notify the abnormality of the alarm variables by using the SNMP trap mechanism. Traps in RMON and SNMP have different monitored targets, triggering conditions, and report contents. RMON provides an efficient means of monitoring subnets. The managed device sends a trap to the management device automatically once an alarm has reached a certain threshold value. Unlike SNMP, the management device does not need to get the values of MIB variables multiple times for comparison. Hence, the communication traffic between the management device and the managed device is reduced. RMON provides statistics and alarm functionality to monitor managed devices. The statistics function tracks traffic information on the network segments connected to its ports; for example, the number of oversize packets received. The alarm function aids in monitoring the value of a specified MIB variable. It also handles such events as traps or logs to be sent to the management device when its value reaches a particular threshold; for example,when the rate of packets received reaches a certain value. The RMON protocol allows multiple monitors or management devices. A monitor provides two ways of data gathering: Using RMON probes from which management devices can get data directly and can control network resources. In this approach, management devices can obtain all RMON MIB information. RMON agents in routers and switches. Management devices exchange data with RMON agents using SNMP operations. Due to system resources limitation, they may not cover all MIB information, but in most cases will cover four groups: alarm, event, history, and statistics. Supermicro supports minimal RMON agent implementation for Ethernet interfaces. Supermicro L2/L3 Switches Configuration Guide 5
6 NMS RMON server RMON Agent - Alarm, event SNMP agent configured History, statistics collection Workstations Workstations Figure RMON-1: RMON Operation 1.2 RMON Groups Supermicro supports four groups from RMON MIB1 defined by RMON specifications: event group, alarm group, history group and statistics group Alarm Group The RMON alarm group monitors specified alarm variables, such as the total number of received packets on an interface. Once an alarm entry is defined, the switch checks the value of the monitored alarm variable at the specified interval. When the value of the monitored variable is greater than or equal to the upper threshold, an upper event is triggered. When the value of the monitored variable is smaller than or equal to the lower threshold, a lower event is triggered. The event is then handled as specified in the event group. Supermicro L2/L3 Switches Configuration Guide 6
7 If the value of a specified alarm MIB variable fluctuates, then the rising alarm and falling alarm alternate, i.e. only the first one triggers an alarm event Event Group The event group defines event indexes and controls the generation and notification of the events triggered by the alarms defined in the alarm group. The events can be handled in either of the following ways: Logging event-related information in the event log table of the RMON MIB of the switch. Trap: Sending a trap to notify the the management device of this event occurring Statistics The RMON statistics function is implemented by either the Ethernet statistics group or the history group. The statistics objects are different for both these groups; however both groups record statistics on the interface as a cumulative sum for a particular period History Group The history group specifies the periodic collection of traffic information statistics on an interface and saves the statistics in the history record table. The statistics data includes bandwidth utilization, number of error packets, and total number of packets Ethernet Statistics Group The statistics group specifies the collection of various traffic statistics information on an Ethernet interface and saves it in the Ethernet statistics table. The statistics data includes network collisions, CRC alignment errors, undersize/oversize packets, broadcasts, multicasts, bytes received, packets received, etc. 1.3 RMON Configuration This section describes the RMON configuration for Supermicro switches Default Configuration Parameter RMON status Default Value Disabled Supermicro L2/L3 Switches Configuration Guide 7
8 Collection Statistics Collection History Alarms Events None None None None Enabling RMON RMON is disabled by default in Supermicro switches. Follow the steps below to enable RMON. Step Command Step 1 configure terminal Step 2 set rmon enable Step 3 end Step 4 Show rmon Description Enters the configuration mode Enables RMON in the switch. Exits the configuration mode. Displays the RMON status. The set rmon disable command disables RMON in the switch. RMON must be enabled before any other RMON configuration. The example below shows the commands used to enable RMON. SMIS# configure terminal SMIS(config)# set rmon enable SMIS(config)# end SMIS# show rmon RMON is enabled Configuring Alarms and Events The alarm group periodically takes statistical samples from variables and compares them with the configured thresholds. When a threshold is crossed, an event is generated using the alarm mechanism. The event group generates events whenever an alarm condition takes place in the device. The alarm group calls the event group, so an event must already be created for the alarm to call. Step Command Description Step 1 configure terminal Enters the configuration mode Step 2 rmon alarm <alarm-number> <mib-object-id (Optional) Sets an alarm on an MIB Supermicro L2/L3 Switches Configuration Guide 8
9 (255)> <sample-interval-time ( )> {absolute delta } rising-threshold <value ( )> <rising-event-number ( )> falling-threshold <value ( )> <falling-event-number ( )> [owner <ownername (127)>] object. alarm-number - Alarm Number. This value ranges between 1 and mib-object-id - The MIB object identifier. sample-interval-time - Time in seconds during which the alarm monitors the MIB variable. This value ranges between 1 and seconds. absolute - Used to test each MIB variable directly. delta - Used to test the change between the samples of a variable. rising-threshold - A number at which the alarm is triggered. This value ranges between 0 and falling-threshold value - A number at which the alarm is reset. This value ranges between 0 and NOTE: The falling threshold must be less than the rising threshold. rising-event-number - The event number to trigger when the rising threshold exceeds its limit. This value ranges between 1 and falling-event-number - The event number to trigger when the falling threshold exceeds its limit. This value ranges between 1 and Step 3 rmon event <number ( )> [description <event-description (127)>] [log] [owner <ownername (127)>] [trap <community (127)>] Owner Owner of the alarm, string of length 127. (Optional) Adds an event in the RMON event table that is associated with an RMON event number. Supermicro L2/L3 Switches Configuration Guide 9
10 Number - Event number Description - Description of the event Log - Used to generate a log entry Owner - Owner of the event,, in range of characters Trap - Used to generate a trap. The SNMP community string is to be passed for the specified trap. Step 4 end Step 5 show rmon [statistics [<stats-index ( )>]] [alarms] [events] [history [history-index ( )] [overview]] NOTE: When an RMON event trap is enabled, the SNMP agent must be configured prior to configuring the RMON alarm function as described in the SNMP Configuration Guide ( Exits the configuration mode. Displays the RMON statistics, alarms, events history and overview. The no rmon alarm <number ( )> and no rmon event <number ( )> commands delete the RMON alarm and RMON event configurations, respectively. When the alarm variable is the MIB variable defined in the history group or the Ethernet statistics group, the RMON Ethernet statistics function or the RMON history statistics function should be configured on the particular Ethernet interface, otherwise the creation of the alarm entry fails and no alarm event is triggered Configuring Statistics The RMON Ethernet statistics group collects statistics for each monitored interface on the switch and stores them in the Ethernet statistics table. Only one statistics entry can be created per interface. The RMON Ethernet history group collects a periodic statistical sampling of the data collected by the Ethernet statistics group and stores them in the Ethernet history table. Multiple history entries can be configured on one interface, however all should have different values. Step Command Step 1 configure terminal Description Enters the configuration mode Supermicro L2/L3 Switches Configuration Guide 10
11 Step 2 interface <interface-type><interface-id> or interface range <interface-type><interface-id>. (Optional) Enters the interface configuration mode. interface-type may be any of the following: gigabit-ethernet gi extreme-ethernet ex qx-ethernet qx interface-id is in slot/port format for all physical interfaces. To configure multiple interfaces, use the interface range command. To provide a range use a hyphen (-) between the start and end interface numbers. E.g.: int range gi 0/1-10 To provide multiple interfaces or ranges, separate with a comma (,). E.g.: int range gi 0/1-10, gi 0/20 Step 3 rmon collection stats <index ( )> [owner <ownername (127)>] If multiple interfaces are provided, the next step will perform the particular configuration on all these interfaces. (Optional) Enables RMON statistics collection on the interface index - Statistics table index, in range of Step 4 rmon collection history <index ( )> [buckets <bucket-number ( )>] [interval <seconds (1-3600)>] [owner <ownername (127)>] owner - Optional field that allows you to enter the name of the owner of the RMON group of statistics with a string length of 127 (Optional) Enables history collection for the specified number of buckets and time period index - History table index, in range of buckets - The maximum number of buckets desired for the RMON collection history group of statistics. Supermicro L2/L3 Switches Configuration Guide 11
12 interval - The number of seconds in each polling cycle, in range of Step 5 show rmon [statistics [<stats-index ( )>]] [alarms] [events] [history [history-index ( )] [overview]] owner - Optional field - allows the user to enter the name of the owner of the RMON group of statistics, string length of 127. Displays RMON statistics, history and overview. The no rmon collection stats <index ( )> and no rmon collection history <index ( )> commands delete the RMON collection configuration RMON Configuration Example A sample RMON configuration of alarms, events and collection statistics and history in a Supermicro switch is specified below. 1) Enable RMON 2) Create events for rising and falling threshold. 3) Create the alarm for the MIB object in table. 4) Create statistics collection on an interface. 5) Display all RMON configurations. SMIS# configure terminal SMIS(config)# set rmon enable SMIS(config)# rmon event 1 description rise log owner smicro1 trap PUBLIC SMIS(config)# rmon event 2 description fall log owner smicro1 trap NETMAN SMIS(config)# rmon alarm absolute rising-threshold 2 1 falling-threshold 1 2 owner smicro1 SMIS(config)# interface Gi 0/5 SMIS(config-if)# rmon collection history 1 buckets 2 interval 20 SMIS(config-if)# rmon collection stats 1 SMIS(config-if)# end SMIS# show rmon statistics Supermicro L2/L3 Switches Configuration Guide 12
13 RMON is enabled Collection 1 on Gi0/5 is active, and owned by monitor, Monitors if Entry.1.5 which has Received 0 octets, 0 packets, 0 broadcast and 0 multicast packets, 0 undersized and 0 oversized packets, 0 fragments and 0 jabbers, 0 CRC alignment errors and 0 collisions. # of packets received of length (in octets): 64: 0, : 0, : 0, : 0, : 0, : 0 SMIS# show rmon events RMON is enabled Event 1 is active, owned by smicro1 Description is rise Event firing causes log and trap to community PUBLIC, Time last sent is Apr 29 10:12: Logging Event With Description: rise Event 2 is active, owned by smicro1 Description is fall Event firing causes log and trap to community NETMAN, Time last sent is Apr 29 10:11: SMIS# show rmon history RMON is enabled Entry 1 is active and owned by Monitors ifentry.1.5 every 20 second(s) Requested # of time intervals, i.e. buckets, is 2, Granted # of time intervals, i.e. buckets, is 2, Sample 2 began measuring at Apr 29 10:13: Received 0 octets, 0 packets, 0 broadcast and 0 multicast packets, 0 undersized and 0 oversized packets, 0 fragments and 0 jabbers, 0 CRC alignment errors and 0 collisions, # of dropped packet events is 0 Network utilization is estimated at 0 Sample 3 began measuring at Apr 29 10:14: Received 0 octets, 0 packets, 0 broadcast and 0 multicast packets, 0 undersized and 0 oversized packets, Supermicro L2/L3 Switches Configuration Guide 13
14 0 fragments and 0 jabbers, 0 CRC alignment errors and 0 collisions, # of dropped packet events is 0 Network utilization is estimated at 0 SMIS# show rmon alarms RMON is enabled Alarm 1 is active, owned by smicro1 Monitors every 2 second(s) Taking absolute samples, last value was 2 Rising threshold is 2, assigned to event 1 Falling threshold is 1, assigned to event 2 On startup enable rising or falling alarm SMIS# show rmon history overview RMON is enabled Entry 1 is active, and owned by Monitors ifentry.1.5 every 20 second(s) Requested # of time intervals, i.e. buckets, is 2, Granted # of time intervals, i.e. buckets, is 2, SMIS# show rmon statistics 1 alarms events history 1 RMON is enabled Collection 1 on Gi0/5 is active, and owned by monitor, Monitors if Entry.1.5 which has Received 0 octets, 0 packets, 0 broadcast and 0 multicast packets, 0 undersized and 0 oversized packets, 0 fragments and 0 jabbers, 0 CRC alignment errors and 0 collisions. # of packets received of length (in octets): 64: 0, : 0, : 0, : 0, : 0, : 0 Alarm 1 is active, owned by smicro1 Monitors every 2 second(s) Taking absolute samples, last value was 2 Rising threshold is 2, assigned to event 1 Falling threshold is 1, assigned to event 2 On startup enable rising or falling alarm Event 1 is active, owned by smicro1 Description is rise Event firing causes log and trap to community PUBLIC, Supermicro L2/L3 Switches Configuration Guide 14
15 Time last sent is Apr 29 10:12: Logging Event With Description: rise Event 2 is active, owned by smicro1 Description is fall Event firing causes log and trap to community NETMAN, Time last sent is Apr 29 10:11: Entry 1 is active, and owned by Monitors ifentry.1.5 every 20 second(s) Requested # of time intervals, i.e. buckets, is 2, Granted # of time intervals, i.e. buckets, is 2, Sample 4 began measuring at Apr 29 10:14: Received 0 octets, 0 packets, 0 broadcast and 0 multicast packets, 0 undersized and 0 oversized packets, 0 fragments and 0 jabbers, 0 CRC alignment errors and 0 collisions, # of dropped packet events is 0 Network utilization is estimated at 0 Sample 5 began measuring at Apr 29 10:14: Received 0 octets, 0 packets, 0 broadcast and 0 multicast packets, 0 undersized and 0 oversized packets, 0 fragments and 0 jabbers, 0 CRC alignment errors and 0 collisions, # of dropped packet events is 0 Network utilization is estimated at 0 SMIS# write startup-config Building configuration, Please wait. May take a few minutes... [OK] SMIS# show running-config Building configuration... Switch ID Hardware Version Firmware Version 0 SBM-GEM-X3S+ (B4-01) vlan 1 ports gi 0/1-24 untagged ports ex 0/1-3 untagged exit set rmon enable rmon event 1 description rise log owner smicro1 trap PUBLIC rmon event 2 description fall log owner smicro1 trap NETMAN rmon alarm absolute rising-thresh Supermicro L2/L3 Switches Configuration Guide 15
16 old 2 1 falling-threshold 1 2 owner smicro1 interface Gi 0/5 rmon collection stats 1 owner monitor rmon collection history 1 buckets 2 interval 20 exit Supermicro L2/L3 Switches Configuration Guide 16
How To Configure Link Aggregation On Supermicro Switch 2 And 3 (Lan) On A Microsoft Vlan 2 And Vlan 3 (Vlan) (Lan 2) (Vlans) (Lummer) (Powerline) (
L2 / L3 Switches Link Aggregation Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility
L2 / L3 Switches. Link Layer Discovery Protocol (LLDP) Configuration Guide
L2 / L3 Switches Link Layer Discovery Protocol (LLDP) Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes
Supermicro Server Monitoring with SuperDoctor 5 and SCOM 2012
Supermicro Server Monitoring with SuperDoctor 5 and SCOM 2012 User s Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes
L2 / L3 Switches. Simple Network Management Protocol (SNMP) Configuration Guide
-- L2 / L3 Switches Simple Network Management Protocol (SNMP) Configuration Guide Revision 1.0 Supermicro L2/L3 Switches Configuration Guide 2 The information in this USER S MANUAL has been carefully reviewed
SBI-7125B-T1 Blade Module RAID Setup Procedure
SBI-7125B-T1 Blade Module RAID Setup Procedure Revison 1.0 SBI-7125B-T1 Blade Module RAID Setup Procedure The information in this User s Manual has been carefully reviewed and is believed to be accurate.
L2/L3 Switches. System. Configuration Guide
L2/L3 Switches System Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies
Switch Quick Configuration CLI Guide for
Switch Quick Configuration CLI Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release : 1.0d 1 /
Dotworkz NVR Series User Manual. Rev 1.26
Dotworkz NVR Series User Manual Rev 1.26 The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that
Switch Web GUI Quick Configuration Guide for
Switch Web GUI Quick Configuration Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release: 1.0c 1
UEFI BIOS Recovery Instructions
UEFI BIOS Recovery Instructions USER S GUIDE Revision 1.0a The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any
How To Configure Rmon On Cisco Me 2600X On Ios 2.5A (Cisco) With A Network Monitor On A Network Device (Network) On A Pnet 2.2.1 (Network Monitor) On An Ip
Remote Network Monitoring and Alarm Troubleshooting This chapter describes remote network monitoring (RMON) and alarm troubleshooting. RMON Procedures, page 1 Understanding RMON, page 1 Alarm Troubleshooting,
Intel PCH RAID Configuration Utility
Intel PCH RAID Configuration Utility USER S MANUAL Revision 1.0a The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for
52-20-15 RMON, the New SNMP Remote Monitoring Standard Nathan J. Muller
52-20-15 RMON, the New SNMP Remote Monitoring Standard Nathan J. Muller Payoff The Remote Monitoring (RMON) Management Information Base (MIB) is a set of object definitions that extend the capabilities
52-20-16 Using RMON to Manage Remote Networks Gilbert Held
52-20-16 Using RMON to Manage Remote Networks Gilbert Held Payoff By standardizing the management information base (MIB) for Ethernet and Token Ring LANs, a network administrator can use the management
Web-based Management Utility
MicroBlade Web-based Management Utility USER S MANUAL Revison.0b MicroBlade Web-based Management Utility USER S MANUAL The information in this USER S MANUAL has been carefully reviewed and is believed
Appendix A Remote Network Monitoring
Appendix A Remote Network Monitoring This appendix describes the remote monitoring features available on HP products: Remote Monitoring (RMON) statistics All HP products support RMON statistics on the
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide
ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide 10/100 Switches SF 300-08, SF 302-08, SF 302-08MP, SF 302-08P, SF 300-24, SF 300-24P, SF 300-48, SF 300-48P Gigabit
ADMINISTRATION GUIDE Cisco Small Business
ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Contents Chapter 1: Getting Started 1 Starting the Web-based Switch Configuration Utility 1 Launching the Configuration
SUPER SMC LCD. User's Guide. Revision 1.0
SUPER SMC LCD User's Guide Revision 1.0 The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that
What is VLAN Routing?
Application Note #38 February 2004 What is VLAN Routing? This Application Notes relates to the following Dell product(s): 6024 and 6024F 33xx Abstract Virtual LANs (VLANs) offer a method of dividing one
Table of Contents. Table of Contents
Table of Contents Table of Contents Chapter 1 System Management Configuration... 1 1.1 File Management Configuration... 1 1.1.1 Managing the file system... 1 1.1.2 Commands for the file system... 1 1.1.3
How to Use SNMP in Network Problem Resolution
The Essentials Series: Solving Network Problems Before They Occur How to Use SNMP in Network Problem Resolution sponsored by KNOW YOUR NETWORK by Greg Shields Ho w to Use SNMP in Network Problem Resolution...
Cisco Small Business 200 Series Smart Switch Administration Guide Release 1.3
ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Release 1.3 Contents Chapter 1: Getting Started 1 Starting the Web-based Configuration Utility 1 Launching the Configuration
Cisco Small Business 300 Series Managed Switch Administration Guide Release 1.2.7
ADMINISTRATION GUIDE Cisco Small Business 300 Series Managed Switch Administration Guide Release 1.2.7 Contents Table of Contents Chapter 1: Getting Started 1 Starting the Web-based Switch Configuration
Network Management & Security (CS 330) RMON
Network Management & Security (CS 330) RMON Dr. Ihsan Ullah Department of Computer Science & IT University of Balochistan, Quetta Pakistan November 08, 2013 CS 330 RMON 1/13 1 / 13 Outline Remote Network
Intel Device View. User Guide
Intel Device View User Guide Year 2000 Capable An Intel product, when used in accordance with its associated documentation, is Year 2000 Capable when, upon installation, it accurately stores, displays,
How Much Broadcast and Multicast Traffic Should I Allow in My Network?
PowerConnect Application Note #5 November 2003 How Much Broadcast and Multicast Traffic Should I Allow in My Network? This Application Note relates to the following Dell PowerConnect products: PowerConnect
Command Line Interface
bridge addressdatabase add Adding a Statically Configured Address to an Address Forwarding Database You can add a statically configured address to a forwarding database using the add command on the addressdatabase
theguard! Service Management Center (Valid for Version 6.3 and higher)
theguard! Service Management Center (Valid for Version 6.3 and higher) Introduction Introduction about the minimal system requirements of theguard! Service Management Center. The theguard! Service Management
Top-Down Network Design
Top-Down Network Design Chapter Nine Developing Network Management Strategies Copyright 2010 Cisco Press & Priscilla Oppenheimer 29 Network Management Design A good design can help an organization achieve
L2 / L3 Switches. Quality of Service (QoS) Configuration Guide
L2 / L3 Switches Quality of Service (QoS) Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. Thevendor assumes no responsibility
Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B
Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication
OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R
OSBRiDGE 5XLi Configuration Manual Firmware 3.10R 1. Initial setup and configuration. OSBRiDGE 5XLi devices are configurable via WWW interface. Each device uses following default settings: IP Address:
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches. Software Release Notes
AT-S41 Version 1.1.4 Management Software for the AT-8326 and AT-8350 Series Fast Ethernet Switches Software Release Notes Please read this document before you begin to use the AT-S41 management software.
Configuring PROFINET
CHAPTER 9 This chapter describes how to configure the PROFINET feature on the Cisco IE 3000 switch. Understanding PROFINET, page 9-1, page 9-4 Displaying the PROFINET Configuration, page 9-5 Troubleshooting
L2 / L3 Switches. Internet Protocol (IP) Configuration Guide
L2 / L3 Switches Internet Protocol (IP) Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
MANAGING NETWORK COMPONENTS USING SNMP
MANAGING NETWORK COMPONENTS USING SNMP Abubucker Samsudeen Shaffi 1 Mohanned Al-Obaidy 2 Gulf College 1, 2 Sultanate of Oman. Email: [email protected] [email protected] Abstract:
Configuring LLDP, LLDP-MED, and Location Service
27 CHAPTER Configuring LLDP, LLDP-MED, and Location Service This chapter describes how to configure the Link Layer Discovery Protocol (LLDP), LLDP Media Endpoint Discovery (LLDP-MED), and Location Service
SSL-Manager (SNMP-SSL Management Software)
SSL-Manager (SNMP-SSL Management Software) User s Manual Table of Contents Chapter 1 Introduction... 3 Chapter 2 Installation... 4 Chapter 3 SSL-Manager Menus... 8 Chapter 4 Setup... 11 Chapter 5 Operation...
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes
AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported
VOIP-211RS/210RS/220RS/440S. SIP VoIP Router. User s Guide
VOIP-211RS/210RS/220RS/440S SIP VoIP Router User s Guide Trademarks Contents are subject to revise without prior notice. All trademarks belong to their respective owners. FCC Warning This equipment has
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches. Software Release Notes
AT-S45 Version 1.0.7 Management Software for the AT-9410GB Gigabit Ethernet Switches Product Documentation Software Release Notes Please read this document before you begin to use the AT-S45 management
User Guide. Smart Switch LGS3XX
User Guide Smart Switch LGS3XX Chapter 1: Getting Started 1 Starting the Web-based Configuration Utility 1 Launching the Configuration Utility 1 Interface Naming Conventions 2 Window Navigation 2 Configuring
How To Use Nnci On A Microsoft Ipfix On A Linux Box 2.2.2 (Amd64) On A Macbook 2.5 (Amd32) On An Ipfix 2.3.2 On A Windows Xp
Configuration System Monitoring Release: 6.2 Document Revision: 06.01 www.nortel.com NN47200-505. . Release: 6.2 Publication: NN47200-505 Document release date: 28 June 2010 While the information in this
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.2 November 2015 Last modified: November 3, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing
NMS300 Network Management System
NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate
AOC-TBT-DSL5320. User Guide 1.0
AOC-TBT-DSL5320 User Guide 1.0 The information in this user guide has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained
CA Nimsoft Monitor. Probe Guide for NT Event Log Monitor. ntevl v3.8 series
CA Nimsoft Monitor Probe Guide for NT Event Log Monitor ntevl v3.8 series Legal Notices Copyright 2013, CA. All rights reserved. Warranty The material contained in this document is provided "as is," and
SC745 X9 Universal Air Shroud User s Guide
SC745 X9 Universal Air Shroud User s Guide Revison 1.0 SC745 Air Shroud User s Guide The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes
TUTORIAL SNMP: STATUS AND APPLICATION FOR LAN/MAN MANAGEMENT. Aiko Pras [email protected]
TUTORIAL SNMP: STATUS AND APPLICATION FOR LAN/MAN MANAGEMENT 9 July 1996 Aiko Pras [email protected] http://wwwtios.cs.utwente.nl/~pras http://wwwtios.cs.utwente.nl/ http://wwwsnmp.cs.utwente.nl/ Copyright
School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management. Lab 4: Remote Monitoring (RMON) Operations
School of Information Technology and Engineering (SITE) CEG 4395: Computer Network Management Lab 4: Remote Monitoring (RMON) Operations Objective To become familiar with basic RMON operations, alarms,
EView/400i Management Pack for Systems Center Operations Manager (SCOM)
EView/400i Management Pack for Systems Center Operations Manager (SCOM) Concepts Guide Version 6.3 November 2012 Legal Notices Warranty EView Technology makes no warranty of any kind with regard to this
How To Configure Voice Vlan On An Ip Phone
1 VLAN (Virtual Local Area Network) is used to logically divide a physical network into several broadcast domains. VLAN membership can be configured through software instead of physically relocating devices
User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer
User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer Revision 1.1 TABLE OF CONTENTS INTRODUCTION... 1 INSTALLATION GUIDE... 2
11.1. Performance Monitoring
11.1. Performance Monitoring Windows Reliability and Performance Monitor combines the functionality of the following tools that were previously only available as stand alone: Performance Logs and Alerts
ProSafe Plus Switch Utility
ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA September 2010 202-10524-03 v1.0 ProSafe Plus Switch Utility User Guide 2010 NETGEAR, Inc. All rights reserved. No
NCD ThinPATH Load Balancing Startup Guide
NCD ThinPATH Load Balancing Startup Guide Copyright Copyright 1999 by Network Computing Devices, Inc. (NCD).The information contained in this document is subject to change without notice. Network Computing
AT-S95 Version 1.0.0.35 AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes
AT-S95 Version 1.0.0.35 AT-8000GS Layer 2 Stackable Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported Platforms The following
Traffic Mirroring Commands on the Cisco ASR 9000 Series Router
Traffic Mirroring Commands on the Cisco ASR 9000 Series Router This module describes the commands used to configure and monitor traffic mirroring. acl, page 2 clear monitor-session counters, page 4 destination
SC815 X9 Universal Air Shroud User s Guide
SC815 X9 Universal Air Shroud User s Guide Revison 1.0 SC815 Air Shroud User s Guide The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes
LSI 2308 SAS Configuration Utility
LSI 2308 SAS Configuration Utility USER S MANUAL Revision 1.0 The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.0 July 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing Disaster Recovery Version 7.0 July
SNMP Informant. SNMP Informant, the default Microsoft SNMP extension agents and WMI January 2009
Informant Systems, Inc. 11135-23A Avenue Edmonton, AB T6J4W5 Canada p: 780.908.6669 f: 780.434.8991 www.informant-systems.com SNMP Informant SNMP Informant, the default Microsoft SNMP extension agents
AG MacOS Standalone Array Client Administration Guide
AG MacOS Standalone Array Client Administration Guide Copyright Statement Copyright Statement Copyright 2015 Array Networks, Inc., 1371 McCarthy Blvd, Milpitas, California 95035, USA. All rights reserved.
AT-GS950/8. AT-GS950/8 Web Users Guide AT-S107 [1.00.043] Gigabit Ethernet Smart Switch. 613-001484 Rev A
AT-GS950/8 Gigabit Ethernet Smart Switch AT-GS950/8 Web Users Guide AT-S107 [1.00.043] 613-001484 Rev A Copyright 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced
Network Monitoring and Diagnostics Connected Manufacturing usa.siemens.com/industry Page 1 What is Network Monitoring and Diagnostics? Network Monitoring A system that is constantly monitoring networks
Virtual LAN Configuration Guide Version 9
Virtual LAN Configuration Guide Version 9 Document version 96-1.0-12/05/2009 2 IMPORTANT NOTICE Elitecore has supplied this Information believing it to be accurate and reliable at the time of printing,
RUGGEDCOM NMS. Monitor Availability Quick detection of network failures at the port and
RUGGEDCOM NMS is fully-featured enterprise grade network management software based on the OpenNMS platform. Specifically for the rugged communications industry, RNMS provides a comprehensive platform for
Network Management 2. Learning Objectives. Centralized network management? School of Business Eastern Illinois University
School of Business Eastern Illinois University 2 (Week 16, Thursday 4/19/2007) Abdou Illia, Spring 2007 Learning Objectives 2 List main elements in Centralized network management Describe Centralized principles
This section describes how to set up, find and delete community strings.
SNMP V1/V2c setup SNMP community strings, page 1 SNMP notification destinations, page 4 SNMP community strings Set up community string This section describes how to set up, find and delete community strings.
WhatsUp Gold v11 Features Overview
WhatsUp Gold v11 Features Overview This guide provides an overview of the core functionality of WhatsUp Gold v11, and introduces interesting features and processes that help users maximize productivity
GWA501 package contains: 1 Wireless-G Broadband Gateway 1 Power Adapter 1 Ethernet Cable 1 Manual CD 1 Quick Start Guide 1 Warranty/Registration Card
Wireless-G Broadband Gateway GWA501 Quick Start Guide Read this guide thoroughly and follow the installation and operation procedures carefully to prevent any damage to the unit and/or any of the devices
SNMP Monitoring: One Critical Component to Network Management
Network Instruments White Paper SNMP Monitoring: One Critical Component to Network Management Although SNMP agents provide essential information for effective network monitoring and troubleshooting, SNMP
Management Software. User s Guide AT-S88. For the AT-FS750/24POE Fast Ethernet Smart Switch. Version 1.0. 613-000555 Rev. B
Management Software AT-S88 User s Guide For the AT-FS750/24POE Fast Ethernet Smart Switch Version 1.0 613-000555 Rev. B Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication
GWA502 package contains: 1 Wireless-G Broadband Router 1 Power Adapter 1 Ethernet Cable 1 Manual CD 1 Quick Start Guide 1 Warranty/Registration Card
Wireless-G Broadband Router GWA502 Quick Start Guide Read this guide thoroughly and follow the installation and operation procedures carefully to prevent any damage to the unit and/or any of the devices
Legal Disclaimers. For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code.
ACS5000 Networking Admin Interface Guide 1/21/2015 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found to comply with the limits for a Class B
AlliedWare Plus OS How To Use sflow in a Network
AlliedWare Plus OS How To Use sflow in a Network Introduction sflow is an industry-standard sampling system that is embedded in Allied Telesis' high-performing Layer 3 switches. sflow enables you to use
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes
AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60
Server Management Agent for Windows User s Guide. Server Management 2.0 and Higher
Server Management Agent for Windows User s Guide Server Management 2.0 and Higher March 2008 . unisys imagine it. done. Server Management Agent for Windows User s Guide Server Management 2.0 and Higher
ehealth Resource Discovery Guide
ehealth Resource Discovery Guide MN-ADMDISGD-001 October 2006 This documentation (the "Documentation") and related computer software program (the "Software") (hereinafter collectively referred to as the
CA Nimsoft Monitor. Probe Guide for Active Directory Server. ad_server v1.4 series
CA Nimsoft Monitor Probe Guide for Active Directory Server ad_server v1.4 series Legal Notices Copyright 2013, CA. All rights reserved. Warranty The material contained in this document is provided "as
NEC Express5800 Series NEC ESMPRO AlertManager User's Guide
NEC Express5800 Series NEC ESMPRO AlertManager User's Guide 7-2006 ONL-4152aN-COMMON-128-99-0606 PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs
mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start
mysensors Information to Users mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
SolarWinds Technical Reference
SolarWinds Technical Reference Understanding Orion Advanced Alerts Orion Alerting... 1 Orion Advanced Alerts... 2 The Alert Process... 2 Alert Status and Action Delays... 3 Alert Creation, Storage and
SolarWinds. Understanding SolarWinds Charts and Graphs Technical Reference
SolarWinds Understanding SolarWinds Charts and Graphs Technical Reference Copyright 1995-2015 SolarWinds Worldwide, LLC. All rights reserved worldwide. No part of this document may be reproduced by any
Chapter 3 Management. Remote Management
Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches
AT-S105 Version 1.2.0 Management Software Release Notes AT-FS750/24POE and AT-FS750/48 Fast Ethernet WebSmart Switches Please read this document before you begin to use the management software. NOTE This
Chapter 4 Management. Viewing the Activity Log
Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in
Nimsoft Monitor. ntevl Guide. v3.6 series
Nimsoft Monitor ntevl Guide v3.6 series Legal Notices Copyright 2012, CA. All rights reserved. Warranty The material contained in this document is provided "as is," and is subject to being changed, without
Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
Chapter 18. Network Management Basics
Network Management Basics > FCAPS Model Chapter 18. Network Management Basics This chapter covers the following topics: FCAPS Model Network Management Architecture Network Management Protocols An Introduction
How To Install An At-S100 (Geo) On A Network Card (Geoswitch)
AT-S100 Version 1.0.3 Patch 1 Management Software for the AT-9000/28 Managed Layer 2 GE ecoswitch and AT-9000/28SP Managed Layer 2 GE ecoswitch Software Release Notes Please read this document before you
TECHNICAL NOTE. FortiGate Traffic Shaping Version 2.80. www.fortinet.com
TECHNICAL NOTE FortiGate Traffic Shaping Version 2.80 www.fortinet.com FortiGate Traffic Shaping Technical Note Version 2.80 March 10, 2006 01-28000-0304-20060310 Copyright 2005 Fortinet, Inc. All rights
WBSn Family. FW Upgrade
WBSn Family FW Upgrade WBSn-2400 and WBSn-2450 Software Version: 1.3.2 Doc version: v1 Jan 2013 WBSn Family FW Upgrade Procedure Copyright 2013 Alvarion All rights reserved. FCC Statement Federal Communication
Exploring the Remote Access Configuration Utility
Exploring the Remote Access Configuration Utility in Ninth-Generation Dell PowerEdge Servers The Remote Access Configuration Utility supports local and remote server management in ninth-generation Dell