Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario

Size: px
Start display at page:

Download "Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario"

Transcription

1 Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.2 November 2015 Last modified: November 3, Nasuni Corporation All Rights Reserved

2 Document Information Testing Disaster Recovery Version 7.2 November 2015 Copyright Copyright by Nasuni Corporation. All rights reserved. Information in this document is subject to change without notice and does not represent a commitment on the part of Nasuni. The software described in this document is furnished under a license agreement. The software may be used only in accordance with the terms of the license agreement. It is against the law to copy the software on any medium. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose without the express written permission of Nasuni Corporation. Notice Although Nasuni Corporation has attempted to ensure the accuracy of the content of this manual, it is possible that this document may contain technical inaccuracies, and typographical or other errors. Nasuni assumes no liability for any error in this publication, and for damages, whether direct, indirect, incidental, consequential or otherwise, that may result from such error, including, but not limited to loss of data or profits. Nasuni provides this publication as is without warranty of any kind, either express or implied, including, but not limited to implied warranties of merchantability or fitness for a particular purpose. Trademarks NASUNI, UNIFS, and the ovals logo are Nasuni trademarks and service marks. All other names, brands and products are the property of their respective owners. Contacting Nasuni Corporation Nasuni Corporation 313 Speen Street Natick, MA Telephone: Sales: Fax: info@nasuni.com Technical Support Telephone: NASUNI ( ) support@nasuni.com Technical support is available 24/7/365 for full production customers.

3 Contents Testing Disaster Recovery Purpose Prerequisites Simulating a Disaster Scenario Scenario Overview Considerations for the Nasuni Management Console Downloading Encryption Keys Simulating a Disaster Downloading and Installing the Nasuni Filer Software Configuring the Nasuni Filer Recovering the Nasuni Filer Side Load Starting the Side Load process Viewing and controlling the Side Load process Index Testing Disaster Recovery iii

4 Purpose This document explains the steps for testing the Disaster Recovery process for restoring the Nasuni Filer in a simulated Disaster Recovery scenario. The Nasuni Filer allows data recovery from the cloud to be nearly instantaneous. In a Disaster Recovery scenario, the Nasuni Filer can reduce the total time to recover data to approximately 15 minutes. The Disaster Recovery test process consists of: Downloading generated encryption keys. Identifying the account with which the Nasuni Filer is associated. Re-installing the Nasuni Filer. Performing Side Load procedure, if available. We assume that you are performing this test on a Nasuni Filer installed on a virtual machine. We further assume that you are testing the Disaster Recovery process using generated encryption keys. Prerequisites Before you begin testing the Disaster Recovery procedure, you should meet the following prerequisites: The Nasuni Filer is installed and properly configured on your network. Data is copied to a volume in the Nasuni Filer. At least one snapshot has been successfully completed on a volume with data. If performing Side Load procedure, the source Nasuni Filer must be running, decommissioned, and using release 7.0 or above. Testing Disaster Recovery 1

5 Simulating a Disaster Scenario Simulating a Disaster Scenario This section describes how to simulate a disaster scenario for the Nasuni Filer, to illustrate the process of disaster recovery. Note: You can also simulate a disaster scenario for the Nasuni Management Console. The procedure is similar. Scenario Overview This section explains how to simulate a disaster recovery by shutting down the Nasuni Filer. Before you shut down the Nasuni Filer, make sure you know the names of your volumes and the data stored in them. After the disaster recovery is complete, you can confirm that your new Nasuni Filer has the correct volumes and associated data. Considerations for the Nasuni Management Console If this Nasuni Filer is under the control of the Nasuni Management Console, first remove the Nasuni Filer from the control of the Nasuni Management Console. Click Services, then select Nasuni Management Console from the list. Select disabled from the NMC Management is drop-down list, then click Save. Downloading Encryption Keys Follow this procedure to download your generated encryption keys: 1. Click Configuration, then select Encryption Keys from the list. The Encryption Keys page appears. Figure 1-1: Encryption Keys page. Testing Disaster Recovery 2

6 Simulating a Disaster Scenario 2. Click Download Generated Keys. Depending on your browser, a message box may appear; if so, navigate to an appropriate folder and save this file. The key is saved with a.pgp extension. For more details, refer to Chapter 11 of the Nasuni Filer Administration Guide. You can download this guide at Simulating a Disaster Follow this procedure to simulate a disaster scenario: 1. Click Status, then select Subscription Status from the list. The Subscription Status page appears. Figure 1-2: Subscription Status page. The following subscription information is displayed: Account Name: Name of the account. Serial Number: The serial number for this subscription. Note the Account Name and the Serial Number for this Nasuni.com account. You can also obtain serial numbers on the Account Status page of the Nasuni Management Console. 2. If you have defined data migrations that you want to use after the disaster recovery, ensure that you record information about the data migrations before shutting down the Nasuni Filer. Click Services, then click View Migrations. 3. It is important to ensure that all data has been protected in cloud storage before shutting down the Nasuni Filer. You can do this manually by performing snapshots on all volumes: select each volume from the Volumes list, then click Take snapshot now. Wait until the New Data in Cache (not yet protected) chart on the Home page shows that there is no unprotected data. This process can take considerable time, depending on the size of the cache and the amount of changed and new data in the cache. Alternatively, during the shutdown process you can specify performing a snapshot before shutting down. Testing Disaster Recovery 3

7 Simulating a Disaster Scenario 4. Click Power on the navigation bar at the top of the page. The Shutdown Filer dialog box appears. Figure 1-3: Shutdown Filer dialog box. Note: To exit and return to the previous page, click the x at the top of the page, or click Cancel. 5. Enter a Username (case-sensitive) and Password (case-sensitive) that has permission to perform this operation. 6. Select Perform snapshot before shutting down. This option performs a snapshot before shutting down the Nasuni Filer. This ensures that data is fully protected in cloud storage before shutting down. However, this process can take considerable time, depending on the size of the cache and the amount of changed and new data in the cache. 7. Click Shutdown. The message The system is shutting down. Click here to cancel the shutdown. appears at the top of the Home page. 8. To stop the shutdown, click the hyperlink marked here. You have 60 seconds to cancel the shutdown. The message Shutdown cancelled at user request. appears at the top of the Home page. The shutdown stops. 9. If you do not stop the shutdown, the Nasuni Filer shuts down and the Nasuni Filer user interface is no longer accessible. At this point, the Nasuni Filer that has been shut down simulates a Nasuni Filer after a disaster. The remainder of this document describes how to recover from a disaster. Testing Disaster Recovery 4

8 Downloading and Installing the Nasuni Filer Software Downloading and Installing the Nasuni Filer Software The first step in recovering from a disaster is to download and install the Nasuni Filer software. To download the Nasuni Filer software from the Nasuni Web site: 1. Obtain the Serial Number and Authorization Code for your Nasuni Filer. You use these in step 2 on page 14. If you have the credentials to log in to your Nasuni.com account ( account.nasuni.com/account/login/), you can obtain the Serial Number and Authorization Code there. If you do not have these credentials, obtain the Serial Number and Authorization Code from the person who has the credentials. You can also obtain the Serial Number and Authorization Code on the Account Status page of the Nasuni Management Console. 2. Download the Nasuni Filer software appropriate for your platform. Regardless of which version of the Nasuni Filer software that you used originally, you can download the latest version. Note: You can perform the disaster recovery process to the same version of the software that you were running, or to a newer version than you were running, but not to an older version. Note: If you already have the software installation file, you do not have to download it again. However, the software installation file must not be older than the version you are recovering. 3. Unzip the Nasuni Filer software file. 4. Install the Nasuni Filer. For details, see the Nasuni Filer Virtualization Guide. You can download this guide at Testing Disaster Recovery 5

9 Downloading and Installing the Nasuni Filer Software 5. Launch the Nasuni Filer. The Nasuni Filer screen appears with a plain white bar on the bottom that indicates the progress of the installation. Figure 1-4: Nasuni Filer installation progress screen. Tip: You can force a file system check (fsck) by holding down the Shift key during this screen. When the file system check (fsck) is done, the usual processing continues. 6. After a few moments, the Nasuni Filer console screen appears, including the initial IP address. Figure 1-5: Nasuni Filer console screen. Tip: If you ever must log into the console service screen, press Enter and sign in. The default login username is service, and the default password is service. 7. Record the Assigned IP Address displayed on the console screen. Testing Disaster Recovery 6

10 Configuring the Nasuni Filer Configuring the Nasuni Filer Now that the Nasuni Filer software is installed, you must configure the new Nasuni Filer. Follow this procedure to configure the Nasuni Filer: 1. Open a Web browser and enter the IP address of the Nasuni Filer using this command: address>:8443 where <IP address> is the IP address. When you attempt to access the Nasuni Filer Home page for the first time, a message may appear indicating that the security certificate is not trusted. You can still access the site to proceed with the initial configuration procedure. Testing Disaster Recovery 7

11 Configuring the Nasuni Filer 2. The Enter the Network Parameters for this Filer page appears. Figure 1-6: Enter the Network Parameters for this Filer page. 3. In the Host Name box, a default hostname for the Nasuni Filer appears. You can accept the default hostname or change it to a customized hostname. The name that you enter is the name you provide to users so they can access the Nasuni Filer. You can use ASCII letters a through z, digits 0 through 9, and hyphens. Note: The Nasuni Filer attempts to register the hostname in the DNS server, so that users can access this host by name. Testing Disaster Recovery 8

12 Configuring the Nasuni Filer 4. In the Network Interface Settings area, for each Device in the list, select the Traffic Group from the drop-down list. Figure 1-7: Network Interface Settings area. You can define your own traffic groups. See step 5 below. 5. Also in the Network Interface Settings area, to configure each Traffic Group, click Edit beside the Traffic Group. The Network Settings page appears. Figure 1-8: Network Settings page. From the Network Type drop-down list, select either Static or DHCP. If you select DHCP (Dynamic Host Configuration Protocol), the IP Address, Netmask, and MTU Value fields become unavailable. Note: DHCP may not be enabled on more than one traffic group. If you select Static, you must provide Network Interface Settings and System Settings. See your IT administrator for assistance. Enter the following information: Enter the static IP address in the IP Address text box. The address of a static device must not already be present on the network. The Nasuni Filer verifies this and displays an error if a collision is detected. Note: If you define more than one static device, the Nasuni Filer checks that the subnets specified do not appear more than once. If this is a high-availability hardware appliance Nasuni Filer, enter the Node 1 IP Address and the Node 2 IP Address in their text boxes. Enter a netmask address in the Netmask text box. Testing Disaster Recovery 9

13 Configuring the Nasuni Filer Enter the MTU value in the MTU Value text box. MTU settings above 1500 are supported. The maximum transmission unit (MTU) is the size (in bytes) of the largest protocol data unit that the layer can pass onwards. A larger MTU brings greater efficiency, because each packet carries more user data, while protocol overheads, such as headers, remain fixed; the resulting higher efficiency means a slight improvement in the bulk protocol throughput. A larger MTU also means processing fewer packets for the same amount of data. However, large packets can occupy a slow link for some time, causing greater delays to following packets, and increasing lag and minimum latency. (Optional) You can specify a gateway for each traffic group. This gateway is used to return traffic for clients outside one of the Nasuni Filer's local networks that do not use the default gateway. In the Gateway text box, enter the IP address for the gateway. Click OK to use these values. Click Cancel to exit this page without making any changes. 6. In the System Settings area, from the Settings Source drop-down list, select either Static or DHCP as the source for system-wide configuration. Figure 1-9: System Settings page. DHCP (Dynamic Host Configuration Protocol): Provides a network IP address for a host on an IP network automatically. The Default Gateway, Search Domain, Primary DNS Server, and Secondary DNS Server fields become unavailable. Testing Disaster Recovery 10

14 Configuring the Nasuni Filer DHCP with custom DNS: Provides a network IP address for a host on an IP network automatically. The Default Gateway field becomes unavailable. Enter the following information: Enter one or more local search domains in the Search Domain text box, each separated by a space. You must enter valid hostnames. You can use search domains to avoid typing the complete address of domains that you use frequently. The search domains that you enter are automatically appended to names that you specify for purposes such as Active Directory configuration, data migration sources, HTTPS proxy, and NTP server. For example, if you specify the search domain mycompany.com, then typing server1 for one of these purposes would connect to server1.mycompany.com. Enter the IP address for your primary DNS server in the Primary DNS server text box. You must enter a valid hostname or IP address. Enter the IP address for your secondary DNS server in the Secondary DNS server text box (if applicable). You must enter a valid hostname or IP address. Static: Address information must be entered manually. Enter the following information: Enter a default gateway address in the Default Gateway text box. The gateway address must match a subnet of a defined static network. Enter one or more local search domains in the Search Domain text box, each separated by a space. You must enter valid hostnames. You can use search domains to avoid typing the complete address of domains that you use frequently. The search domains that you enter are automatically appended to names that you specify for purposes such as Active Directory configuration, data migration sources, HTTPS proxy, and NTP server. For example, if you specify the search domain mycompany.com, then typing server1 for one of these purposes would connect to server1.mycompany.com. Enter the IP address for your primary DNS server in the Primary DNS server text box. You must enter a valid hostname or IP address. Enter the IP address for your secondary DNS server in the Secondary DNS server text box (if applicable). You must enter a valid hostname or IP address. 7. To configure a proxy in order to reach HTTPS resources on the Internet, select the Configure A Proxy check box. 8. Click Continue to proceed. Testing Disaster Recovery 11

15 Configuring the Nasuni Filer 9. The Review the Network Settings page appears. Figure 1-10: Review the Network Settings page. To accept the network settings, click Confirm. To return to the previous page to change network settings, click Back. 10. The Configuring Network Settings page appears. Figure 1-11: Configuring Network Settings page. Testing Disaster Recovery 12

16 Configuring the Nasuni Filer 11. For high availability Nasuni Filer hardware appliances, such as the NF-400H, the Filer HA-Pair Synchronization page appears. Figure 1-12: Filer HA-Pair Synchronization page. It can take some time for the synchronization process to complete. When the process completes, click Continue. 12. You are automatically directed to the specified IP address (or you can click the link here ). Testing Disaster Recovery 13

17 Recovering the Nasuni Filer Recovering the Nasuni Filer After configuring the network settings for the new Nasuni Filer, you must enter your Nasuni.com serial number and authorization code, accept the end-user license agreement, and enter a user name and password for the user who is a Filer Administrator of the Nasuni Filer. Important: Internet connectivity (HTTPS port 443) is a prerequisite for setting up the Nasuni Filer, or to update software during the installation. To recover your Nasuni Filer, follow these steps: 1. After you have configured your network, open the specific URL to continue. The Enter your serial number and authorization code wizard page appears. Figure 1-13: Enter your serial number and authorization code wizard page. 2. Enter a Filer Serial Number and Authorization code, found under the Account section of or on the Account Status page of the Nasuni Management Console. For a new installation, choose an unused Filer Serial Number. To recover a prior installation, such as during disaster recovery, choose the Filer Serial Number of the prior installation. Click Continue to proceed. Note: If this Nasuni Filer was reset, and this Nasuni Filer was under the control of the Nasuni Management Console, and if you are using the Filer Serial Number of a prior installation, you must wait 1 hour from the time that you reset the Nasuni Filer before entering the Filer Serial Number and Authorization code and clicking Continue. Testing Disaster Recovery 14

18 Recovering the Nasuni Filer 3. The Perform Disaster Recovery on existing Filer page appears. Figure 1-14: Perform Disaster Recovery on existing Filer page. Enter Perform Disaster Recovery in the Confirmation text box, then click Continue to proceed. Testing Disaster Recovery 15

19 Recovering the Nasuni Filer 4. The second Perform Disaster Recovery on existing Filer page appears. Figure 1-15: Second Perform Disaster Recovery on existing Filer page. If you escrowed your encryption keys with Nasuni, and do not have your encryption keys, and you need Nasuni to de-escrow your encryption keys, select Yes from the drop-down list. Contact Nasuni to receive your encryption keys, then enter your recovered encryption keys and click Continue. Otherwise, select No from the drop-down list, then click Continue. Important: If you have previously escrowed your encryption keys with Nasuni, and you use these escrowed encryption keys as part of the disaster recovery process, you MUST reescrow those encryption keys with Nasuni if you want those encryption keys to continue to be escrowed with Nasuni. After the disaster recovery is complete, the Nasuni Filer treats all encryption keys as if they were not created by this Nasuni Filer. For details, see, Escrowing Encryption Keys with Nasuni on page If you selected No, the Upload Encryption Keys page appears. Figure 1-16: Upload Encryption Keys page. Click Choose File to navigate to your encryption key file, enter the Key Passphrase if necessary, then click Upload Key(s). If several encryption key files are necessary, this page could appear several times. Testing Disaster Recovery 16

20 Recovering the Nasuni Filer 6. The Ready to perform disaster recovery! page appears. Figure 1-17: Ready to perform disaster recovery! page. Click Continue. Disaster recovery of the Nasuni Filer begins. 7. After recovery, the Filer Recovery Complete page appears. Figure 1-18: Filer Recovery Complete page. Testing Disaster Recovery 17

21 Recovering the Nasuni Filer 8. Click Continue. The Accept the Terms of Service and License Agreement page appears. Figure 1-19: Accept the Terms of Service and License Agreement page. You can print or download a copy of the Terms of Service and License Agreement by clicking the appropriate icon. Select I accept the Terms of Service, then click Continue. Testing Disaster Recovery 18

22 Recovering the Nasuni Filer 9. The Enter a username and password for Administration of this Filer page appears. Figure 1-20: Enter a username and password for Administration of this Filer page. Set up your account by creating a Username (case-sensitive) and a Password (case-sensitive). Click Continue. 10. The recovery and restoration process is complete. The Configuration Complete page appears. Figure 1-21: Configuration Complete page. You can reboot the Nasuni Filer, or click the link here to proceed directly to the Login page. 11. The Nasuni Filer becomes available in a few moments. The Login page appears. Figure 1-22: Nasuni Filer Login page. Testing Disaster Recovery 19

23 Recovering the Nasuni Filer Log in to the Nasuni Filer with your Username (case-sensitive) and Password (case-sensitive). Click Log in. Important: If the previous Nasuni Filer was in Active Directory mode, you must re-join Active Directory to maintain ACL support. With the new instance of the Nasuni Filer running, you have regained access to your volumes and data. You can access volumes and data using the CIFS shares, NFS exports, or FTP directories that you created before the disaster. Folders and files are available. Important: If this Nasuni Filer used a CIFS migration source to perform data migrations, you might need to manually reconnect to that CIFS migration source. See Configuring a CIFS Migration Source on page 201. Tip: If this Nasuni Filer previously accessed a volume with custom permissions for Remote Access, you must explicitly set the permissions of that volume for this Nasuni Filer. Important: If you have previously escrowed your encryption keys with Nasuni, and you used these escrowed encryption keys as part of the disaster recovery process, you MUST re-escrow those encryption keys with Nasuni if you want those encryption keys to continue to be escrowed with Nasuni. After the disaster recovery is complete, the Nasuni Filer treats all encryption keys as if they were not created by this Nasuni Filer. For details, see, Escrowing Encryption Keys with Nasuni on page 291. Tip: A best practice for Nasuni Filers is to join an Active Directory domain as soon as disaster recovery is complete. If the previous Nasuni Filer was in Active Directory mode, re-join Active Directory by clicking Save Settings. If the previous Nasuni Filer has not previously joined any domain, see Joining a Nasuni Filer (that has not previously joined any domain) to a domain on page 272. Tip: If this Nasuni Filer was under the control of the Nasuni Management Console, return it to the control of the Nasuni Management Console. Click Services, then select Nasuni Management Console from the list. Select disabled from the NMC Management is drop-down list, then click Save. 12. After verifying that the new Nasuni Filer is running and includes all the expected data, you can delete the old Nasuni Filer. Testing Disaster Recovery 20

24 Side Load Side Load Nasuni supports a Disaster Recovery (DR) process that enables you to recover the Nasuni Filer after a true disaster, such as the loss of a data center. However, most of the time, customers perform the Disaster Recovery process in order to upgrade from one piece of hardware to another. In such a situation, there is a working Nasuni Filer in your data center that contains active data in the cache. Performing the Disaster Recovery process results in a new Nasuni Filer that has an empty cache. The customer often then re-populates the new cache with data, which can require considerable inbound bandwidth from the cloud, and which can take days, weeks, or even months to complete. The Side Load feature enables you to transfer cache data directly from the source Nasuni Filer to the new Nasuni Filer. The source Nasuni Filer must already be decommissioned. Tip: Only one Side Load process is permitted at a time for each Nasuni Filer. Tip: Only the Admin user can perform the Side Load process. Tip: The source Nasuni Filer must be: Running; Decommissioned; Using release 7.0 or above. Warning: If the total data available on the source Nasuni Filer exceeds the available cache space on the new Nasuni Filer, you receive a warning message and notification. You can configure Notifications to notify you by when the Side Load process completes. Testing Disaster Recovery 21

25 Side Load Starting the Side Load process To start the Side Load process from the source Nasuni Filer to the current Nasuni Filer, follow these steps: 1. On the current or destination Nasuni Filer, click Services, then select Side Load from the list. The Side Load page appears. Figure 1-23: Side Load page. Note: If this Nasuni Filer is under Nasuni Management Console control, this page is not available on the Nasuni Filer. Instead, use the Nasuni Management Console to view information or perform actions. 2. In the Host Address text box, enter the host address of the source Nasuni Filer. The source Nasuni Filer must already be decommissioned. 3. In the Username text box, enter the username for the specified source Nasuni Filer. The source Nasuni Filer must already be decommissioned. 4. In the Password text box, enter the password for the specified Username for the specified source Nasuni Filer. The source Nasuni Filer must already be decommissioned. 5. Click Connect and Start. A connection is established with the data of the source Nasuni Filer. Data begins moving to the current Nasuni Filer. After the data transfer starts, you can view the progress of the Side Load process. 6. When the Side Load process completes, the Complete label appears on the bar graph. Tip: Record any information you want to retain from the screen before clicking Done. Click Done. Testing Disaster Recovery 22

26 Side Load Viewing and controlling the Side Load process To view or control the progress of the Side Load process, follow these steps: 1. Click Services, then select Side Load from the list. If the Side Load process has not yet completed, the Side Load - Status page appears. Figure 1-24: Side Load - Status page. Note: If this Nasuni Filer is under Nasuni Management Console control, this page is not available on the Nasuni Filer. Instead, use the Nasuni Management Console to view information or perform actions. The following information appears: Host Address: The host address of the source Nasuni Filer. The source Nasuni Filer must already be decommissioned. Progress: A bar graph indicating the progress of the Side Load process. The percentage of the Side Load process that is complete appears. If the Side Load process is running, the Running label appears. If the Side Load process is paused, the Paused label appears. Data Processed: The amount of data processed (in KB, MB, GB, or TB) and the total amount of data to process (in KB, MB, GB, or TB). Est. Rate: The estimated rate of data transfer (in KB/S, MB/S, GB/S, or TB/S). Est. Time Remaining: The estimated time until the Side Load process is complete. Testing Disaster Recovery 23

27 Side Load 2. To pause a running Side Load process, click Pause. The Side Load process pauses indefinitely. The bar graph label changes to Paused. Figure 1-25: Side Load - Status page, paused. To continue with the Side Load process after a pause, click Resume. The Side Load process continues. The bar graph label changes to Running. 3. To cancel the Side Load process, click Cancel. The Cancel Side Load dialog box appears. Figure 1-26: Cancel Side Load dialog box. To cancel the Side Load process, click Continue. If the Side Load process is canceled, the bar graph label changes to Canceled. Figure 1-27: Side Load status page, canceled. Tip: Record any information you want to retain from the screen before clicking Done. Testing Disaster Recovery 24

28 Side Load 4. When the Side Load process completes, the Complete label appears on the bar graph. Tip: Record any information you want to retain from the screen before clicking Done. 5. Click Done. Testing Disaster Recovery 25

29 Index 8443 port 7 account name 3 ACL 20 Active Directory 11, 20 Authorization Code 5 authorization code 14 creating password 19 username A C D decommissioned 21, 22 DHCP 9, 10, 11 network type 9, 10 disaster recovery encryption key 16 file 16 downloading software Nasuni.com account 5 encryption key disaster recovery 16 file 3 disaster recovery 16 E F file encryption key 3 file disaster recovery 16 Filer Administrator 14 fsck 6 gateway traffic group 10 high availability network configuration 9 HTTPS proxy 11 G H IP address 9, 11 primary DNS server 11 secondary DNS server 11 I Testing Disaster Recovery 26

30 M maximum transmission unit 10 MTU 10 N name account 3 Nasuni.com account downloading software 5 netmask 9 network configuration high availability 9 Network Time Protocol NTP 11 network type DHCP 9, 10 static 9, 10, 11 NTP Network Time Protocol 11 time server 11 static network type 9, 10, 11 traffic group gateway 10 username creating 19 for shutdown 4 T U password creating 19 shutdown 4 pausing Side Load 24 port primary DNS 11 primary DNS server IP address 11 P secondary DNS 11 secondary DNS server IP address 11 serial number 5, 14 setting up Nasuni Filer 14 shutdown 4 password 4 power 4 username 4 shutdown window 4 Side Load 21, 23 pausing 24 snapshot before shutdown 4 S Testing Disaster Recovery 27

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.0 July 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing Disaster Recovery Version 7.0 July

More information

Nasuni Management Console Guide

Nasuni Management Console Guide Nasuni Management Console Guide Version 5.5 April 2014 2014 Nasuni Corporation All Rights Reserved Document Information Nasuni Management Console Guide Version 5.5 April 2014 Copyright Copyright 2010-2014

More information

Nasuni Filer Initial Configuration Guide

Nasuni Filer Initial Configuration Guide Nasuni Filer Initial Configuration Guide Version 7.2 November 2015 Last modified: November 16, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Nasuni Filer Initial Configuration Guide

More information

Nasuni Filer Virtualization Getting Started Guide. Version 7.5 June 2016 Last modified: June 9, 2016 2016 Nasuni Corporation All Rights Reserved

Nasuni Filer Virtualization Getting Started Guide. Version 7.5 June 2016 Last modified: June 9, 2016 2016 Nasuni Corporation All Rights Reserved Nasuni Filer Virtualization Getting Started Guide Version 7.5 June 2016 Last modified: June 9, 2016 2016 Nasuni Corporation All Rights Reserved Document Information Nasuni Filer Virtualization Getting

More information

Nasuni Filer Administration Guide

Nasuni Filer Administration Guide Nasuni Filer Administration Guide Version 7.2 November 2015 Last modified: November 6, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Nasuni Filer Administration Guide Version 7.2

More information

Nasuni Filer Administration Guide

Nasuni Filer Administration Guide Nasuni Filer Administration Guide Version 7.5 May 2016 Last modified: May 23, 2016 2016 Nasuni Corporation All Rights Reserved Document Information Nasuni Filer Administration Guide Version 7.5 May 2016

More information

Encryption Key Best Practices Nasuni Corporation Natick, MA

Encryption Key Best Practices Nasuni Corporation Natick, MA Nasuni Corporation Natick, MA Summary of Best Practices Recommendations The best practices for managing encryption keys for the Nasuni Filer include the following: If your enterprise has existing OpenPGP-compatible

More information

Best Practices Guide. Version 7.2. November 2015 Last modified: November 16, 2015 2015 Nasuni Corporation All Rights Reserved

Best Practices Guide. Version 7.2. November 2015 Last modified: November 16, 2015 2015 Nasuni Corporation All Rights Reserved Best Practices Guide Version 7.2 November 2015 Last modified: November 16, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Best Practices Guide Version 7.2 November 2015 Copyright

More information

Nasuni Filer Best Practices Guide

Nasuni Filer Best Practices Guide Nasuni Filer Best Practices Guide Version 5.0 July 2013 2013 Nasuni Corporation All Rights Reserved Document Information Nasuni Filer Best Practices Guide Version 5.0 July 2013 Copyright Copyright 2010-2013

More information

Virtual Web Appliance Setup Guide

Virtual Web Appliance Setup Guide Virtual Web Appliance Setup Guide 2 Sophos Installing a Virtual Appliance Installing a Virtual Appliance This guide describes the procedures for installing a Virtual Web Appliance. If you are installing

More information

Virtual Managment Appliance Setup Guide

Virtual Managment Appliance Setup Guide Virtual Managment Appliance Setup Guide 2 Sophos Installing a Virtual Appliance Installing a Virtual Appliance As an alternative to the hardware-based version of the Sophos Web Appliance, you can deploy

More information

Server Installation Guide ZENworks Patch Management 6.4 SP2

Server Installation Guide ZENworks Patch Management 6.4 SP2 Server Installation Guide ZENworks Patch Management 6.4 SP2 02_016N 6.4SP2 Server Installation Guide - 2 - Notices Version Information ZENworks Patch Management Server Installation Guide - ZENworks Patch

More information

Barracuda Link Balancer Administrator s Guide

Barracuda Link Balancer Administrator s Guide Barracuda Link Balancer Administrator s Guide Version 1.0 Barracuda Networks Inc. 3175 S. Winchester Blvd. Campbell, CA 95008 http://www.barracuda.com Copyright Notice Copyright 2008, Barracuda Networks

More information

Installing and Configuring vcloud Connector

Installing and Configuring vcloud Connector Installing and Configuring vcloud Connector vcloud Connector 2.7.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

WhatsUp Gold v16.2 Installation and Configuration Guide

WhatsUp Gold v16.2 Installation and Configuration Guide WhatsUp Gold v16.2 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.2 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines

More information

Citrix XenServer Workload Balancing 6.5.0 Quick Start. Published February 2015 1.0 Edition

Citrix XenServer Workload Balancing 6.5.0 Quick Start. Published February 2015 1.0 Edition Citrix XenServer Workload Balancing 6.5.0 Quick Start Published February 2015 1.0 Edition Citrix XenServer Workload Balancing 6.5.0 Quick Start Copyright 2015 Citrix Systems. Inc. All Rights Reserved.

More information

F-Secure Messaging Security Gateway. Deployment Guide

F-Secure Messaging Security Gateway. Deployment Guide F-Secure Messaging Security Gateway Deployment Guide TOC F-Secure Messaging Security Gateway Contents Chapter 1: Deploying F-Secure Messaging Security Gateway...3 1.1 The typical product deployment model...4

More information

CIFS Permissions Best Practices Nasuni Corporation Natick, MA

CIFS Permissions Best Practices Nasuni Corporation Natick, MA Nasuni Corporation Natick, MA Overview You use permissions to control user access to data. There are two basic considerations when using permissions to control user access to data: Which users have access

More information

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner

More information

Backup & Disaster Recovery Appliance User Guide

Backup & Disaster Recovery Appliance User Guide Built on the Intel Hybrid Cloud Platform Backup & Disaster Recovery Appliance User Guide Order Number: G68664-001 Rev 1.0 June 22, 2012 Contents Registering the BDR Appliance... 4 Step 1: Register the

More information

Quick Start Guide For Ipswitch Failover v9.0

Quick Start Guide For Ipswitch Failover v9.0 For Ipswitch Failover v9.0 Copyright 1991-2015 All rights reserved. This document, as well as the software described in it, is furnished under license and may be used or copied only in accordance with

More information

Installing and Using the vnios Trial

Installing and Using the vnios Trial Installing and Using the vnios Trial The vnios Trial is a software package designed for efficient evaluation of the Infoblox vnios appliance platform. Providing the complete suite of DNS, DHCP and IPAM

More information

Privileged Access Management Upgrade Guide

Privileged Access Management Upgrade Guide Privileged Access Management Upgrade Guide 2015 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are the property

More information

User Guide. CTERA Agent. August 2011 Version 3.0

User Guide. CTERA Agent. August 2011 Version 3.0 User Guide CTERA Agent August 2011 Version 3.0 Copyright 2009-2011 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written permission

More information

Installing and Configuring vcenter Support Assistant

Installing and Configuring vcenter Support Assistant Installing and Configuring vcenter Support Assistant vcenter Support Assistant 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

CTERA Agent for Linux

CTERA Agent for Linux User Guide CTERA Agent for Linux September 2013 Version 4.0 Copyright 2009-2013 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written

More information

CTERA Agent for Windows

CTERA Agent for Windows User Guide CTERA Agent for Windows May 2012 Version 3.1 Copyright 2009-2012 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written

More information

Virtual Appliance Setup Guide

Virtual Appliance Setup Guide The Virtual Appliance includes the same powerful technology and simple Web based user interface found on the Barracuda Web Application Firewall hardware appliance. It is designed for easy deployment on

More information

SevOne NMS Download Installation and Implementation Guide

SevOne NMS Download Installation and Implementation Guide SevOne NMS Download Installation and Implementation Guide 5.3.X 530 V0002 Contents 1. Get Started... 3 2. SevOne Download Installation... 6 3. Appliance Network Configuration... 9 4. Install License and

More information

WhatsUp Gold v16.3 Installation and Configuration Guide

WhatsUp Gold v16.3 Installation and Configuration Guide WhatsUp Gold v16.3 Installation and Configuration Guide Contents Installing and Configuring WhatsUp Gold using WhatsUp Setup Installation Overview... 1 Overview... 1 Security considerations... 2 Standard

More information

Savvius Insight Initial Configuration

Savvius Insight Initial Configuration The configuration utility on Savvius Insight lets you configure device, network, and time settings. Additionally, if you are forwarding your data from Savvius Insight to a Splunk server, You can configure

More information

StorSimple Appliance Quick Start Guide

StorSimple Appliance Quick Start Guide StorSimple Appliance Quick Start Guide 5000 and 7000 Series Appliance Software Version 2.1.1 (2.1.1-267) Exported from Online Help on September 15, 2012 Contents Getting Started... 3 Power and Cabling...

More information

CTERA Agent for Mac OS-X

CTERA Agent for Mac OS-X User Guide CTERA Agent for Mac OS-X September 2013 Version 4.0 Copyright 2009-2013 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without

More information

SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide

SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide Copyright and Trademark Statements 2014 ViewSonic Computer Corp. All rights reserved. This document contains proprietary information that

More information

NetBak Replicator 4.0 User Manual Version 1.0

NetBak Replicator 4.0 User Manual Version 1.0 NetBak Replicator 4.0 User Manual Version 1.0 Copyright 2012. QNAP Systems, Inc. All Rights Reserved. 1 NetBak Replicator 1. Notice... 3 2. Install NetBak Replicator Software... 4 2.1 System Requirements...

More information

WhatsUp Gold v16.1 Installation and Configuration Guide

WhatsUp Gold v16.1 Installation and Configuration Guide WhatsUp Gold v16.1 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.1 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines

More information

Quick Install Guide. Lumension Endpoint Management and Security Suite 7.1

Quick Install Guide. Lumension Endpoint Management and Security Suite 7.1 Quick Install Guide Lumension Endpoint Management and Security Suite 7.1 Lumension Endpoint Management and Security Suite - 2 - Notices Version Information Lumension Endpoint Management and Security Suite

More information

WatchGuard Dimension v1.1 Update 1 Release Notes

WatchGuard Dimension v1.1 Update 1 Release Notes WatchGuard Dimension v1.1 Update 1 Release Notes Build Number 442674 Revision Date March 25, 2014 WatchGuard Dimension is the next-generation cloud-ready visibility solution for our Unified Threat Management

More information

READYNAS INSTANT STORAGE. Quick Installation Guide

READYNAS INSTANT STORAGE. Quick Installation Guide READYNAS INSTANT STORAGE Quick Installation Guide Table of Contents Step 1 Connect to FrontView Setup Wizard 3 Installing RAIDar on Windows 3 Installing RAIDar on Mac OS X 3 Installing RAIDar on Linux

More information

vsphere Replication for Disaster Recovery to Cloud

vsphere Replication for Disaster Recovery to Cloud vsphere Replication for Disaster Recovery to Cloud vsphere Replication 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

File Auditor for NAS, Net App Edition

File Auditor for NAS, Net App Edition File Auditor for NAS, Net App Edition Installation Guide Revision 1.2 - July 2015 This guide provides a short introduction to the installation and initial configuration of NTP Software File Auditor for

More information

Interworks. Interworks Cloud Platform Installation Guide

Interworks. Interworks Cloud Platform Installation Guide Interworks Interworks Cloud Platform Installation Guide Published: March, 2014 This document contains information proprietary to Interworks and its receipt or possession does not convey any rights to reproduce,

More information

Cyberoam Virtual Security Appliance - Installation Guide for XenServer. Version 10

Cyberoam Virtual Security Appliance - Installation Guide for XenServer. Version 10 Cyberoam Virtual Security Appliance - Installation Guide for XenServer Version 10 Document Version 10.6.1-01/07/2014 Contents Preface... 4 Base Configuration... 4 Installation Procedure... 4 Cyberoam Virtual

More information

ReadyNAS Setup Manual

ReadyNAS Setup Manual ReadyNAS Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA October 2007 208-10163-01 v1.0 2007 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR, the NETGEAR logo,

More information

Installing and Configuring vcloud Connector

Installing and Configuring vcloud Connector Installing and Configuring vcloud Connector vcloud Connector 2.0.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

DFS Configuration and Best Practices Nasuni Corporation Natick, MA

DFS Configuration and Best Practices Nasuni Corporation Natick, MA Nasuni Corporation Natick, MA Windows Distributed File System (DFS) Windows Distributed File System (DFS) is a technology with which most Windows administrators are already familiar. DFS allows administrators

More information

Dell One Identity Cloud Access Manager 8.0.1 - How to Configure Microsoft Office 365

Dell One Identity Cloud Access Manager 8.0.1 - How to Configure Microsoft Office 365 Dell One Identity Cloud Access Manager 8.0.1 - How to Configure Microsoft Office 365 May 2015 This guide describes how to configure Microsoft Office 365 for use with Dell One Identity Cloud Access Manager

More information

SOA Software API Gateway Appliance 7.1.x Administration Guide

SOA Software API Gateway Appliance 7.1.x Administration Guide SOA Software API Gateway Appliance 7.1.x Administration Guide Trademarks SOA Software and the SOA Software logo are either trademarks or registered trademarks of SOA Software, Inc. Other product names,

More information

SolarWinds Migrating SolarWinds NPM Technical Reference

SolarWinds Migrating SolarWinds NPM Technical Reference SolarWinds Migrating SolarWinds NPM Technical Reference Copyright 1995-2015 SolarWinds Worldwide, LLC. All rights reserved worldwide. No part of this document may be reproduced by any means nor modified,

More information

Set Up Panorama. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright 2007-2015 Palo Alto Networks

Set Up Panorama. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright 2007-2015 Palo Alto Networks Set Up Panorama Palo Alto Networks Panorama Administrator s Guide Version 6.0 Contact Information Corporate Headquarters: Palo Alto Networks 4401 Great America Parkway Santa Clara, CA 95054 www.paloaltonetworks.com/company/contact-us

More information

Integrated Citrix Servers

Integrated Citrix Servers Installation Guide Supplement for use with Integrated Citrix Servers Websense Web Security Websense Web Filter v7.5 1996-2010, Websense, Inc. 10240 Sorrento Valley Rd., San Diego, CA 92121, USA All rights

More information

PHD Virtual Backup for Hyper-V

PHD Virtual Backup for Hyper-V PHD Virtual Backup for Hyper-V version 7.0 Installation & Getting Started Guide Document Release Date: December 18, 2013 www.phdvirtual.com PHDVB v7 for Hyper-V Legal Notices PHD Virtual Backup for Hyper-V

More information

Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual

Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual www.hillstonenet.com Preface Conventions Content This document follows the conventions below: CLI Tip: provides

More information

Quality of Service (bandwidth limitation): Default is 2 megabits per second.

Quality of Service (bandwidth limitation): Default is 2 megabits per second. Worksheets for Configuring Nasuni Filers, Volumes, and Shares Filer Configuration You can use the worksheet below to plan the features of a Nasuni Filer. These settings appear on the Configuration tab

More information

Arcserve Cloud. Arcserve Cloud Getting Started Guide

Arcserve Cloud. Arcserve Cloud Getting Started Guide Arcserve Cloud Arcserve Cloud Getting Started Guide This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the Documentation ) is

More information

F-SECURE MESSAGING SECURITY GATEWAY

F-SECURE MESSAGING SECURITY GATEWAY F-SECURE MESSAGING SECURITY GATEWAY DEFAULT SETUP GUIDE This guide describes how to set up and configure the F-Secure Messaging Security Gateway appliance in a basic e-mail server environment. AN EXAMPLE

More information

A Guide to New Features in Propalms OneGate 4.0

A Guide to New Features in Propalms OneGate 4.0 A Guide to New Features in Propalms OneGate 4.0 Propalms Ltd. Published April 2013 Overview This document covers the new features, enhancements and changes introduced in Propalms OneGate 4.0 Server (previously

More information

emerge 50P emerge 5000P

emerge 50P emerge 5000P emerge 50P emerge 5000P Initial Software Setup Guide May 2013 Linear LLC 1950 Camino Vida Roble Suite 150 Carlsbad, CA 92008 www.linearcorp.com Copyright Linear LLC. All rights reserved. This guide is

More information

Dell One Identity Cloud Access Manager 7.0.2. Installation Guide

Dell One Identity Cloud Access Manager 7.0.2. Installation Guide Dell One Identity Cloud Access Manager 7.0.2 2014 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished under

More information

NTP Software QFS for NAS, NetApp Edition Installation Guide

NTP Software QFS for NAS, NetApp Edition Installation Guide NTP Software QFS for NAS, NetApp Edition Installation Guide This Installation Guide applies to all NTP Software QFS for NAS, NetApp filer editions. Abstract This guide provides a short introduction to

More information

Use QNAP NAS for Backup

Use QNAP NAS for Backup Use QNAP NAS for Backup BACKUP EXEC 12.5 WITH QNAP NAS Copyright 2010. QNAP Systems, Inc. All Rights Reserved. V1.0 Document revision history: Date Version Changes Apr 2010 1.0 Initial release Note: Information

More information

vsphere Replication for Disaster Recovery to Cloud

vsphere Replication for Disaster Recovery to Cloud vsphere Replication for Disaster Recovery to Cloud vsphere Replication 5.8 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

CTERA Agent for Mac OS-X

CTERA Agent for Mac OS-X User Guide CTERA Agent for Mac OS-X June 2014 Version 4.1 Copyright 2009-2014 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written

More information

nappliance misa Server 2006 Standard Edition Users Guide For use with misa Appliances 2006 nappliance Networks, Inc.

nappliance misa Server 2006 Standard Edition Users Guide For use with misa Appliances 2006 nappliance Networks, Inc. nappliance misa Server 2006 Standard Edition Users Guide For use with misa Appliances The information contained in this document represents the current view of Microsoft Corporation on the issues discussed

More information

Connection Broker Managing User Connections to Workstations, Blades, VDI, and More. Quick Start with Microsoft Hyper-V

Connection Broker Managing User Connections to Workstations, Blades, VDI, and More. Quick Start with Microsoft Hyper-V Connection Broker Managing User Connections to Workstations, Blades, VDI, and More Quick Start with Microsoft Hyper-V Version 8.1 October 21, 2015 Contacting Leostream Leostream Corporation http://www.leostream.com

More information

Dell One Identity Cloud Access Manager 8.0 - How To Deploy Cloud Access Manager in a Virtual Private Cloud

Dell One Identity Cloud Access Manager 8.0 - How To Deploy Cloud Access Manager in a Virtual Private Cloud Dell One Identity Cloud Access Manager 8.0 - How To Deploy Cloud Access Manager in a Virtual Private Cloud February 2015 This guide describes how to deploy Dell One Identity Cloud Access Manager within

More information

RSA Authentication Manager 8.1 Virtual Appliance Getting Started

RSA Authentication Manager 8.1 Virtual Appliance Getting Started RSA Authentication Manager 8.1 Virtual Appliance Getting Started Thank you for purchasing RSA Authentication Manager 8.1, the world s leading two-factor authentication solution. This document provides

More information

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide Symantec Backup Exec TM 11d for Windows Servers Quick Installation Guide September 2006 Symantec Legal Notice Copyright 2006 Symantec Corporation. All rights reserved. Symantec, Backup Exec, and the Symantec

More information

CaseWare Time. CaseWare Cloud Integration Guide. For Time 2015 and CaseWare Cloud

CaseWare Time. CaseWare Cloud Integration Guide. For Time 2015 and CaseWare Cloud CaseWare Time CaseWare Cloud Integration Guide For Time 2015 and CaseWare Cloud Copyright and Trademark Notice Copyright. 2015 CaseWare International Inc. ( CWI ). All Rights Reserved. Use, duplication,

More information

XMS Quick Start Guide

XMS Quick Start Guide 812-0055-002D XMS Quick Start Guide Overview of Quick Start Steps This guide will quickly get you up and running with the Xirrus Management System (XMS). It includes instructions for setting up the XMS

More information

Sophos for Microsoft SharePoint startup guide

Sophos for Microsoft SharePoint startup guide Sophos for Microsoft SharePoint startup guide Product version: 2.0 Document date: March 2011 Contents 1 About this guide...3 2 About Sophos for Microsoft SharePoint...3 3 System requirements...3 4 Planning

More information

NTP Software File Auditor for Windows Edition

NTP Software File Auditor for Windows Edition NTP Software File Auditor for Windows Edition An NTP Software Installation Guide Abstract This guide provides a short introduction to installation and initial configuration of NTP Software File Auditor

More information

CTERA Portal Datacenter Edition

CTERA Portal Datacenter Edition User Guide CTERA Portal Datacenter Edition September 2011 Version 3.0 Copyright 2009-2011 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means

More information

How to Test Out Backup & Replication 6.5 for Hyper-V

How to Test Out Backup & Replication 6.5 for Hyper-V How to Test Out Backup & Replication 6.5 for Hyper-V Mike Resseler May, 2013 2013 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication

More information

GlobalSCAPE DMZ Gateway, v1. User Guide

GlobalSCAPE DMZ Gateway, v1. User Guide GlobalSCAPE DMZ Gateway, v1 User Guide GlobalSCAPE, Inc. (GSB) Address: 4500 Lockhill-Selma Road, Suite 150 San Antonio, TX (USA) 78249 Sales: (210) 308-8267 Sales (Toll Free): (800) 290-5054 Technical

More information

LumInsight CMS Installation Guide

LumInsight CMS Installation Guide LumInsight CMS Installation Guide This guide walks you through the installation steps to run your LumInsight CMS software. 078-1059-01C Echelon, LumInsight, and the Echelon logo are trademarks of Echelon

More information

Installing, Uninstalling, and Upgrading Service Monitor

Installing, Uninstalling, and Upgrading Service Monitor CHAPTER 2 Installing, Uninstalling, and Upgrading Service Monitor This section contains the following topics: Preparing to Install Service Monitor, page 2-1 Installing Cisco Unified Service Monitor, page

More information

Dell One Identity Cloud Access Manager 8.0.1 - How to Configure for SSO to SAP NetWeaver using SAML 2.0

Dell One Identity Cloud Access Manager 8.0.1 - How to Configure for SSO to SAP NetWeaver using SAML 2.0 Dell One Identity Cloud Access Manager 8.0.1 - How to Configure for SSO to SAP NetWeaver using SAML 2.0 May 2015 About this guide Prerequisites and requirements NetWeaver configuration Legal notices About

More information

UltraBac Documentation. UBDR Gold. Administrator Guide UBDR Gold v8.0

UltraBac Documentation. UBDR Gold. Administrator Guide UBDR Gold v8.0 UltraBac Documentation UBDR Gold Bare Metal Disaster Recovery Administrator Guide UBDR Gold v8.0 UBDR Administrator Guide UBDR Gold v8.0 The software described in this guide is furnished under a license

More information

How To Backup Your Computer With A Remote Drive Client On A Pc Or Macbook Or Macintosh (For Macintosh) On A Macbook (For Pc Or Ipa) On An Uniden (For Ipa Or Mac Macbook) On

How To Backup Your Computer With A Remote Drive Client On A Pc Or Macbook Or Macintosh (For Macintosh) On A Macbook (For Pc Or Ipa) On An Uniden (For Ipa Or Mac Macbook) On Remote Drive PC Client software User Guide -Page 1 of 27- PRIVACY, SECURITY AND PROPRIETARY RIGHTS NOTICE: The Remote Drive PC Client software is third party software that you can use to upload your files

More information

Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010

Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 This document describes the different types of Unisphere management stations and tells how to install

More information

Database Backup and Recovery Guide

Database Backup and Recovery Guide Scout Diagnostics Database Backup and Recovery Guide P H 803. 358. 3600 F A X 803. 358. 3636 WWW.AVTECINC.COM 100 I N N O VAT I O N P L ACE, L E X I N G T O N SC 29072 Copyright 2013 by Avtec, Inc. All

More information

Dell One Identity Cloud Access Manager 8.0.1- How to Configure for High Availability

Dell One Identity Cloud Access Manager 8.0.1- How to Configure for High Availability Dell One Identity Cloud Access Manager 8.0.1- How to Configure for High Availability May 2015 Cloning the database Cloning the STS host Cloning the proxy host This guide describes how to extend a typical

More information

vtcommander Installing and Starting vtcommander

vtcommander Installing and Starting vtcommander vtcommander vtcommander provides a local graphical user interface (GUI) to manage Hyper-V R2 server. It supports Hyper-V technology on full and core installations of Windows Server 2008 R2 as well as on

More information

Quick Start Guide for Parallels Virtuozzo

Quick Start Guide for Parallels Virtuozzo PROPALMS VDI Version 2.1 Quick Start Guide for Parallels Virtuozzo Rev. 1.1 Published: JULY-2011 1999-2011 Propalms Ltd. All rights reserved. The information contained in this document represents the current

More information

EMC Data Domain Management Center

EMC Data Domain Management Center EMC Data Domain Management Center Version 1.1 Initial Configuration Guide 302-000-071 REV 04 Copyright 2012-2015 EMC Corporation. All rights reserved. Published in USA. Published June, 2015 EMC believes

More information

Dell Enterprise Reporter 2.5. Configuration Manager User Guide

Dell Enterprise Reporter 2.5. Configuration Manager User Guide Dell Enterprise Reporter 2.5 2014 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished under a software license

More information

RealPresence Platform Director

RealPresence Platform Director RealPresence CloudAXIS Suite Administrators Guide Software 1.3.1 GETTING STARTED GUIDE Software 2.0 June 2015 3725-66012-001B RealPresence Platform Director Polycom, Inc. 1 RealPresence Platform Director

More information

HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide

HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide Abstract This guide describes the Virtualization Monitor (vmon), an add-on service module of the HP Intelligent Management

More information

VMTurbo Operations Manager 4.5 Installing and Updating Operations Manager

VMTurbo Operations Manager 4.5 Installing and Updating Operations Manager VMTurbo Operations Manager 4.5 Installing and Updating Operations Manager VMTurbo, Inc. One Burlington Woods Drive Burlington, MA 01803 USA Phone: (781) 373---3540 www.vmturbo.com Table of Contents Introduction

More information

Rally Installation Guide

Rally Installation Guide Rally Installation Guide Rally On-Premises release 2015.1 rallysupport@rallydev.com www.rallydev.com Version 2015.1 Table of Contents Overview... 3 Server requirements... 3 Browser requirements... 3 Access

More information

VERITAS Backup Exec TM 10.0 for Windows Servers

VERITAS Backup Exec TM 10.0 for Windows Servers VERITAS Backup Exec TM 10.0 for Windows Servers Quick Installation Guide N134418 July 2004 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software

More information

GX-V. Quick Start Guide. Microsoft Hyper-V Hypervisor. Before You Begin SUMMARY OF TASKS. Before You Begin WORKSHEET VIRTUAL GMS SERVER

GX-V. Quick Start Guide. Microsoft Hyper-V Hypervisor. Before You Begin SUMMARY OF TASKS. Before You Begin WORKSHEET VIRTUAL GMS SERVER Quick Start Guide GX-V VIRTUAL GMS SERVER Microsoft Hyper-V Hypervisor 2012 Silver Peak Systems, Inc. Before You Begin Windows 2008 server installed and Hyper-V is running Hyper-V management software is

More information

Secure Web Service - Hybrid. Policy Server Setup. Release 9.2.5 Manual Version 1.01

Secure Web Service - Hybrid. Policy Server Setup. Release 9.2.5 Manual Version 1.01 Secure Web Service - Hybrid Policy Server Setup Release 9.2.5 Manual Version 1.01 M86 SECURITY WEB SERVICE HYBRID QUICK START USER GUIDE 2010 M86 Security All rights reserved. 828 W. Taft Ave., Orange,

More information

Foglight. Foglight for Virtualization, Free Edition 6.5.2. Installation and Configuration Guide

Foglight. Foglight for Virtualization, Free Edition 6.5.2. Installation and Configuration Guide Foglight Foglight for Virtualization, Free Edition 6.5.2 Installation and Configuration Guide 2013 Quest Software, Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright.

More information

PROMISE ARRAY MANAGEMENT (PAM) for

PROMISE ARRAY MANAGEMENT (PAM) for PROMISE ARRAY MANAGEMENT (PAM) for FastTrak SX4030, SX4060 and S150 SX4-M User Manual Version 1.1 PAM for FastTrak SX4030, SX4060 and S150 SX4-M User Manual Copyright 2004 Promise Technology, Inc. All

More information

SuperLumin Nemesis. Administration Guide. February 2011

SuperLumin Nemesis. Administration Guide. February 2011 SuperLumin Nemesis Administration Guide February 2011 SuperLumin Nemesis Legal Notices Information contained in this document is believed to be accurate and reliable. However, SuperLumin assumes no responsibility

More information

SonicWALL SSL VPN 3.5: Virtual Assist

SonicWALL SSL VPN 3.5: Virtual Assist SonicWALL SSL VPN 3.5: Virtual Assist Document Scope This document describes how to use the SonicWALL Virtual Assist add-on for SonicWALL SSL VPN security appliances. This document contains the following

More information

Hyper V Windows 2012 and 8. Virtual LoadMaster for Microsoft Hyper V on Windows Server 2012, 2012 R2 and Windows 8. Installation Guide

Hyper V Windows 2012 and 8. Virtual LoadMaster for Microsoft Hyper V on Windows Server 2012, 2012 R2 and Windows 8. Installation Guide Virtual LoadMaster for Microsoft Hyper V on Windows Server 2012, 2012 R2 and Windows 8 Installation Guide VERSION: 3.0 UPDATED: SEPTEMBER 2015 Copyright Notices Copyright 2002 2015 KEMP Technologies, Inc..

More information

Avalanche Remote Control User Guide. Version 4.1.3

Avalanche Remote Control User Guide. Version 4.1.3 Avalanche Remote Control User Guide Version 4.1.3 ii Copyright 2012 by Wavelink Corporation. All rights reserved. Wavelink Corporation 10808 South River Front Parkway, Suite 200 South Jordan, Utah 84095

More information