L2 / L3 Switches. Simple Network Management Protocol (SNMP) Configuration Guide
|
|
|
- Horatio Welch
- 10 years ago
- Views:
Transcription
1 -- L2 / L3 Switches Simple Network Management Protocol (SNMP) Configuration Guide Revision 1.0
2 Supermicro L2/L3 Switches Configuration Guide 2
3 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at Super Micro Computer, Inc. ( Supermicro ) reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent. IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USETHIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCHDAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE,SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OFREPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE,SOFTWARE, OR DATA. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product. FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense. California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. Perchlorate Material-special handling may apply. See for further details. Manual Revision 1.0 Release Date: August 15, 2013 Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders. Copyright 2013 by Super Micro Computer, Inc. All rights reserved. Printed in the United States of America Supermicro L2/L3 Switches Configuration Guide 3
4 Contents 1 SNMP Configuration Guide SNMP Basics SNMP Support Interface Numbers SNMP Defaults Enable/Disable SNMP Agent Access control Engine Identifier Community User Group View Group Access Trap Target Address Target Parameters SNMP Notify Trap UDP Port Authentication traps Sub-Agent SNMP configuration example Supermicro L2/L3 Switches Configuration Guide 4
5 1 SNMP Configuration Guide This document describes the Simple Network Management Protocol (SNMP) feature supported in Supermicro Layer 2 / Layer 3 switch products. This document covers the SNMP configurations for the Supermicro switch products listed below. Top of Rack Switches SSE-G24-TG4 SSE-G48-TG4 SSE-X24S SSE-X3348S SSE-X3348T Blade Switches SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM The majority of this document applies to all the above listed Supermicro switch products. The content of any particular sub section however, might vary across these switch product models. In those sections the differences are clearly identified with reference to particular switch product models. If any particular switch product model is not referenced, the reader can safely assume that the content is applicable to all the above listed models. Throughout this document, the common term switch refers to any of the above listed Supermicro switch product models unless a particular switch product model is noted. 1.1 SNMP Basics SNMP helps to monitor and manage the switches from network management systems (NMS). SNMP solutions contain three major components SNMP manager, SNMP agent and MIB (Management Information Base) as shown in Figure SNMP-1. The SNMP MIB contains all the configuration and status information of the switch. MIB is organized in a tree structure with branches and leaf nodes. Each node contains an object of information and is identified with an object identifier (OID). SNMP MIB is stored and maintained in the switch. Supermicro L2/L3 Switches Configuration Guide 5
6 The SNMP agent also resides on the switch. It processes the SNMP requests received from the SNMP manager. It sends responses to SNMP managers by retrieving required information from the MIB. It also updates the MIB based on SNMP messages sent by the SNMP managers. SNMP agents also send voluntary traps to SNMP managers. Traps are sent to alert the SNMP managers on events happening on the switch. The SNMP manager is an NMS application. It monitors and manages switches by communicating to the SNMP agents running on the switch. The SNMP manager application provides command or graphical interfaces to the network administrators to help them manage the networks. Figure SNMP-1: SNMP Systems SNMP Messages SNMP AGENT MIB SNMP Manager Switch There are three versions of SNMP protocols available. SNMPv3 SNMPv1 First version of SNMP protocol SNMPv2c * Improvements over SNMPv1 * Community string based administration * 64 bit counters support * getbulk support to retrieve large info * Introduced inform messages * Improved error handling Improvements over SNMPv2c Improved authentication - based on SNMP engine ID Improved security - encrypted information USM (User based Security Model) and VACM (View based Access Control Model) are the main features in SNMPv3. USM provides user authentication and message encryption. VACM provides MIB access control by associating views and users. SNMPv3 uses a combination of security model and security level to define switch access. Security model specifies the authentication mechanism for the user and the group to which the user belongs. The security models in the Supermicro switch are v1, v2c and v3. Supermicro L2/L3 Switches Configuration Guide 6
7 Security level specifies the permitted security within the particular security model. The security levels in Supermicro switches are NoAuthNoPriv AuthNoPriv AuthPriv The security model and level combinations possible in Supermicro switch are listed in the table below. V1 V2c Security Model Security Level Authentication Encryption Purpose noauthnopriv Community string None noauthnopriv Community string None V3 noauthnopriv User name None V3 Auth MD5 or SHA None V3 Priv None DES Community string and community user are used to authenticate user login. Community string and community user are used to authenticate user login. User configuration is used to authenticate user login. MD5 or SHA algorithm is used to verify user login. DES is used to encrypt all SNMP messages. SNMP uses multiple messages between managers and agents. The below table describes the SNMP messages. Message Type Originator Receiver Purpose get-request Manager Agent To get the value of a particular MIB object get-next-request Manager Agent To get the value of the next object in a table get-bulk-request Manager Agent To get the values of multiple MIB objects in one transaction get-response Agent Master Response for get-request, get-next-request and get-bulk-request messages. set-request Manager Agent To set the value of a particular MIB object Trap Agent Master To notify the events occurring on agents Inform Agent Master To guarantee delivery of traps to Manager 1.2 SNMP Support Supermicro switches support three versions of SNMP: SNMPv1, SNMPv2c and SNMPv3. A switch supports 50 users, 50 groups, 50 views and 50 views. Supermicro L2/L3 Switches Configuration Guide 7
8 1.3 Interface Numbers IF-MIB contains information about all the interfaces on the switch. Users can access the interface specific MIB object values using interface index (ifindex) numbers. The ifindex numbers are assigned by switch software for every physical and logical interface. The table below shows ifindex to interface mapping method. Interface Type 1Gig physical interfaces 10Gig physical interfaces 40Gig physical interfaces Port channel interfaces Layer 3 interfaces ifindex Starts from 1 and goes up to the maximum number of 1Gig interfaces available on the switch. For SSE-G24-TG4, SBM-GEM-X2C, SBM-GEM-X2C+, SBM-GEM-X3S+: 1 to 24 For SSE-G48-TG4: 1 to 48 For SSE-X24S and SBM-XEM-X10S: 1 For SSE-X3348S: 1 to 2 For SSE-X3348T: 1 to 2 Starts after 1Gig ifindexes and goes up to the maximum number of 10Gig interfaces available on the switch. For SSE-G24-TG4, SBM-GEM-X2C, SBM-GEM-X2C+, SBM-GEM-X3S+: 25 to 28 For SSE-G48-TG4: 49 to 52 For SSE-X24S and SBM-XEM-X10S: 2 to 25 For SSE-X3348S: 3 to 50 For SSE-X3348T: 3 to 50 Startsg after 10Gig ifindexes and goes up to the maximum number of 40Gig interfaces available on the switch. For SSE-X3348S: 51 to 54 For SSE-X3348T: 51 to 54 Starts after 10Gig / 40Gig ifindexes and goes up to the maximum number of port channel interfaces supported on the switch. For SSE-G24-TG4, SBM-GEM-X2C, SBM-GEM-X2C+, SBM-GEM-X3S+: 29 to 52 For SSE-G48-TG4: 53 to 76 For SSE-X24S and SBM-XEM-X10S: 26 to 49 For SSE-X3348S: 55 to 78 For SSE-X3348T: 55 to 78 Starts after port channel ifindexes and goes up to the maximum number of layer 3 interfaces supported on the switch. On switch models SSE-G24-TG4, SSE-G48-TG4, SSE-X24S, SSE-X3348S and SSE-X3348T, the default VLAN 1 and stacking VLAN 4069 takes the first two layer 3 ifindexes. On switch models SBM-GEM-X2C, SBM-GEM-X2C+, SBM-GEM-X3S+ and SBM-XEM-X10S, the first three layer 3 ifindexes are assigned for CMM 1 IP interface, CMM 2 IP interface and stacking VLAN User created layer 3 interfaces follow the above ifindexes. Supermicro L2/L3 Switches Configuration Guide 8
9 In stacking cases, the port channel interface ifindex starts after the physical interfaces of all the stack switches. The ifindexes for all the stack physical interfaces are assigned irrespective of the presence of the particular member switch. Switch 0 1G 10G 40G Switch 1 1G 10G 40G Switch 2 to Switch 16 Similar to Switch 0 and 1 Port Channel Layer 3 Interfaces 1.4 SNMP Defaults Function Default Value SNMP Agent Status Enabled SNMP Sub-Agent Status Disabled Version 3 Engine Id c Communities PUBLIC, NETMAN initial, Users TemplateMD5, TemplateSHA initial : none Authentication TemplateMD5: MD5 (for default users) TemplateSHA: SHA Privacy (for default users) Groups Access View (for default groups) Notify View Name Read, Write, Notify Target Parameters Storage Type Context SNMP Port 161 SNMP Trap Port 162 Trap Status Enabled Authentication Trap Disabled initial : none TemplateMD5: none TemplateSHA: DES iso, initial iso, initial iso: iso, initial: restricted iss, iss1 Iso Internet, test1 Volatile None Supermicro L2/L3 Switches Configuration Guide 9
10 1.5 Enable/Disable the SNMP Agent The SNMP Agent is enabled by default in Supermicro switches. Follow the steps below to disable the SNMP agent. Step Command Step 1 configure terminal Step 2 disable snmpagent Description Enters the configuration mode Disables the SNMP agent Step 3 end Step 4 show snmp Exits the configuration mode. Displays the SNMP information. Step 5 write startup-config Optional step saves this SNMP configuration to be part of the startup configuration. The enable snmp agent command enables the SNMP agent. To enable the SNMP agent, it must be in the disabled state. The SNMP subagent is disabled by default. If needed, use the command disable snmp subagent to disable the SNMP subagent feature. The examples below show ways to disable/enable the SNMP agent function on Supermicro switches. Disable the SNMP agent. SMIS(config)# disable snmpagent SMIS(config)# end Enable the SNMP agent. SMIS(config)# enable snmpagent SMIS(config)# end 1.6 Access Control There are various parameters that control access to the SNMP Agent. Engine ID Supermicro L2/L3 Switches Configuration Guide 10
11 Community String User Group Group Access Engine Identifier The SNMP Engine Identifier is a unique identifier for the SNMP agent in a switch. It is used with a hashing function in the agent to generate keys for authentication and encryption. Hence after any change in the Engine Identifier, the following must be re-configured: SNMPv3 authentication SNMPv3 encryption/privacy Community Follow the steps below to configure the SNMP Engine Identifier. Step Command Step 1 configure terminal Step 2 snmp engineid <EngineIdentifier> Step 3 end Step 4 show snmp engineid Step 5 write startup-config Description Enters the configuration mode Configures the SNMP Engine Identifier. EngineIdentifier- Hexadecimal number, with length between 5 and 32 octets. Each octet should be separated by a period. Exits the configuration mode. Displays the SNMP engine Identifier information. Optional step saves this SNMP configuration to be part of the startup configuration. The example below shows the commands used to configure the SNMP Engine Identifier. SMIS(config)# snmp engineid c SMIS(config)# end SMIS# show snmp engineid EngineId: c Supermicro L2/L3 Switches Configuration Guide 11
12 The no snmp engineid command resets the SNMP engineid to its default value of c Community An SNMP community defines a group of devices and management systems. Only devices and management systems that are members of the same community can exchange SNMP messages. A device or management system can be a member of multiple communities. The SNMP v1/v2 community is also used as a form of security. The community of SNMP managers that can access the agent MIB in the switch is defined by a community string. Follow the steps below to configure an SNMP community. Step Command Step 1 configure terminal Step 2 snmp community index <CommunityIndex> name <CommunityName> security <SecurityName> [context <name>] [{volatile nonvolatile}] [transporttag <TransportTagIdentifier none>] Description Enters the configuration mode Configures the SNMP community. CommunityIndex Alphanumeric value with a maximum of 32 characters. CommunityName Alphanumeric value with a maximum of 255 characters. SecurityName This is the user name associated with the community. Alphanumeric value with a maximum of 40 characters. Name Alphanumeric value with a maximum of 40 characters. TransportTagIdentifier Identifies the transport end points between agent and manager. Alphanumeric value with a maximum of 255 characters. Step 3 end Step 4 show snmp community Step 5 write startup-config Exits the configuration mode. Displays the SNMP community information. Optional step saves this SNMP configuration to be part of the startup configuration. Supermicro L2/L3 Switches Configuration Guide 12
13 The no snmp community index <CommunityIndex> command deletes the specified community index. The example below shows the commands used to configure the SNMP community. SMIS(config)# snmp community index test1 name test1 security user1 nonvolatile SMIS(config)# show snmp community Community Index: NETMAN Community Name: NETMAN Security Name: none Context Name: Transport Tag: Community Index: PUBLIC Community Name : PUBLIC Security Name: none Context Name : Transport Tag: Community Index: test1 Community Name: test1 Security Name: user1 Context Name: Transport Tag: Storage Type: Non-volatile User SNMP user configuration is used only for SNMPv3. An SNMP user requests and receives information about switch status and traps. Follow the steps below to configure an SNMP user. Step Command Description Step 1 configure terminal Enters the configuration mode Step 2 snmp user <UserName> [auth{md5 sha} Configures the SNMP user, Supermicro L2/L3 Switches Configuration Guide 13
14 <passwd> [priv DES <passwd>]] [{volatile nonvolatile}] authentication and encryption. UserName - Alphanumeric value with a maximum of 40 characters. Use auth to enable authentication for the user. Passwd Password used for user Authentication. Alphanumeric value with a maximum of 40 characters. Use priv to enable encryption of packets. Passwd Password used to generate keys for encryption of messages. Alphanumeric value with a maximum of 40 characters. Use volatile if the value need not be stored in NVRAM. Use nonvolatile if the value must be stored in NVRAM and available after restart. Step 3 end Step 4 show snmp user Exits the configuration mode. Displays the SNMP user information. Step 5 write startup-config Optional step saves this SNMP configuration to be part of the startup configuration. The no snmp user <UserName> command deletes the specified user. The example below shows the commands used to configure the SNMP user. SMIS(config)# snmp user user5 auth md5 abc123 priv DES xyz123 SMIS# end Supermicro L2/L3 Switches Configuration Guide 14
15 SMIS# show snmp user Engine ID: c User: user5 Authentication Protocol: MD5 Privacy Protocol: DES_CBC Engine ID: c User: initial Authentication Protocol: None Privacy Protocol: None Engine ID: c User: templatemd5 Authentication Protocol: MD5 Privacy Protocol: None Engine ID: c User: templatesha Authentication Protocol: SHA Privacy Protocol: DES_CBC Group A group identifies a set of users in SNMPv3. Follow the steps below to configure an SNMP group. Step Command Step 1 configure terminal Step 2 snmp group <GroupName> user <UserName> security-model {v1 v2c v3 } [{volatile nonvolatile}] Description Enters the configuration mode Configures the SNMP group. GroupName Alphanumeric value with a maximum of 40 characters. Security-model Use v1 or v2c or v3. UserName - Alphanumeric value with a Supermicro L2/L3 Switches Configuration Guide 15
16 maximum of 40 characters. Use volatile if the value need not be stored in NVRAM. Step 3 end Step 4 show snmp group Use nonvolatile if the value must be stored in NVRAM and available after restart. Exits the configuration mode. Displays the SNMP group information. Step 5 write startup-config Optional step saves this SNMP configuration to be part of the startup configuration. The no snmp group <GroupName> user <UserName> security-model {v1 v2c v3} command deletes the specified group. The example below shows the commands used to configure the SNMP group. SMIS(config)# snmp group group5 user user5 security-model v3 SMIS# end SMIS# show snmp group Security Model: v1 Security Name: none Group Name: iso Security Model: v2c Security Name: none Group Name: iso Security Model: v3 Security Name: user5 Group Name: group5 Supermicro L2/L3 Switches Configuration Guide 16
17 Security Model: v3 Security Name: initial Group Name: initial Storage Type: Non-volatile Security Model: v3 Security Name: templatemd5 Group Name: initial Storage Type: Non-volatile Security Model: v3 Security Name: templatesha Group Name: initial Storage Type: Non-volatile View A view specifies limited access to MIBs. A view can be associated with one or many groups. In an SNMP, parameters are arranged in a tree format. SNMP uses an Object Identifier (OID) to identify the exact parameter in the tree. An OID is a list of numbers separated by periods. Follow the steps below to configure the SNMP view. Step Command Step 1 configure terminal Step 2 snmp view <ViewName> <OIDTree> [mask <OIDMask>] {included excluded} [{volatile nonvolatile}] Description Enters the configuration mode Configures the SNMP view. ViewName- Alphanumeric value with a maximum of 40 characters. OIDTree OID number, with a maximum of 32 numbers. OIDMask OID number, with a maximum of 32 numbers. Use included to specify that the MIB sub-tree is included in the view. Use excluded to specify that the MIB sub-tree is excluded from the view. Supermicro L2/L3 Switches Configuration Guide 17
18 Use volatile if the value need not be stored in NVRAM. Step 3 end Step 4 show snmp viewtree Use nonvolatile if the value must be stored in NVRAM and available after restart. Exits the configuration mode. Displays the SNMP view information. Step 5 write startup-config Optional step saves this SNMP configuration to be part of the startup configuration. The no snmp view <ViewName> <OIDTree> command deletes the specified SNMP view. The example below shows the commands used to configure the SNMP view. SMIS(config)# snmp view view included SMIS(config)# show snmp viewtree View Name: iso Subtree OID: 1 Subtree Mask: 1 View Type: Included Storage Type: Non-volatile View Name: view1 Subtree OID: Subtree Mask: View Type: Included View Name: Restricted Subtree OID: 1 Subtree Mask: 1 View Type: Excluded Storage Type: Non-volatile Supermicro L2/L3 Switches Configuration Guide 18
19 1.6.6 Group Access Group access defines the access policy for a set of users belonging to a particular group. Group access is used only for SNMPv3. Follow the steps below to configure SNMP group access. Step Command Step 1 configure terminal Step 2 snmp access <GroupName> {v1 v2c v3 {auth noauth priv}} [read <ReadView none>] [write <WriteView none>] [notify <NotifyView none>] [{volatile nonvolatile}] Description Enters the configuration mode Configures the SNMP group access. GroupName - Alphanumeric value with a maximum of 40 characters. Security model Mention one of v1, v2c or v3. Use auth to enable authentication for the user. Use priv to enable encryption of packets. ReadView- View name that specifies read access to particular MIB sub-tree. Alphanumeric value with a maximum of 40 characters. WriteView View name that specifies write access to particular MIB sub-tree. Alphanumeric value with a maximum of 40 characters. NotifyView View name that specifies a particular MIB sub-tree used in notification. Alphanumeric value with a maximum of 40 characters. Use volatile if the value need not be stored in NVRAM. Step 3 end Step 4 show snmp group access Use nonvolatile if the value must be stored in NVRAM and available after restart. Exits the configuration mode. Displays the SNMP group access information. Supermicro L2/L3 Switches Configuration Guide 19
20 Step 5 write startup-config Optional step saves this SNMP configuration to be part of startup configuration. Group, user and view should be created before configuring group access. The no snmp access <GroupName> {v1 v2c v3 {auth noauth priv}} command deletes the specified SNMP group access. The example below shows the commands used to configure the SNMP group access. SMIS(config)# snmp access group5 v3 auth read view1 write view2 notify none nonvolatile SMIS(config)# end SMIS# show snmp group access Group Name: iso Read View: iso Write View: iso Notify View: iso Group Name: iso Read View: iso Write View: iso Notify View: iso Group Name: group5 Read View: view1 Write View: view2 Notify View: Storage Type: Non-volatile Group Name: Initial Read View: Restricted Write View: Rrestricted Notify View: Restricted Storage Type: Non-volatile Supermicro L2/L3 Switches Configuration Guide 20
21 Group Name: Initial Read View: iso Write View: iso Notify View: iso Storage Type: Non-volatile Group Name: initial Read View: iso Write View: iso Notify View: iso Storage Type: Non-volatile 1.7 Trap Target Address A target is a receiver of SNMP notification(s), which are usually SNMP Managers. The target address defines the transport parameters of the receivers. Follow the steps below to configure the SNMP Target address. Step Command Step 1 configure terminal Step 2 snmp targetaddr <TargetAddressName> param <ParamName> {<IPAddress> <IP6Address>} [timeout <Seconds(1-1500)] [retries <RetryCount(1-3)] [taglist <TagIdentifier none>] [{volatile nonvolatile}] Description Enters the configuration mode Configures the SNMP target address information. TargetAddressName - Alphanumeric value with a maximum of 40 characters. ParamName The parameter to be notified to the specific target. Alphanumeric value with a maximum of 40 characters. IPAddress IPv4 address of the target. IP6Address IPv6 address of the target. Seconds Specifies the timeout within which the target should be reachable. RetryCount Specifies the number of retries to reach the target. Supermicro L2/L3 Switches Configuration Guide 21
22 TagIdentifier- A set of targets can be grouped under a tag Identifier. Use volatile if the value need not be stored in NVRAM. Step 3 end Step 4 show snmp targetaddr Step 5 write startup-config Use nonvolatile if the value must be stored in NVRAM and available after restart. Exits the configuration mode. Displays the SNMP target address information. Optional step saves this SNMP configuration to be part of the startup configuration. The no snmp targetaddr <TargetAddressName> command deletes the specified SNMP target address information. The example below shows the commands used to configure the SNMP target address. SMIS(config)# snmp targetaddr host1 param param taglist tg1 SMIS# end SMIS# show snmp targetaddr Target Address Name: host1 IP Address: Tag List: tg1 Parameters: param Target Parameters Target parameters define the MIB objects that should be notified to an SNMP target, usually an SNMP manager. Follow the steps below to configure SNMP target parameters. Supermicro L2/L3 Switches Configuration Guide 22
23 Step Command Step 1 configure terminal Step 2 snmp targetparams <ParamName> user <UserName> security-model {v1 v2c v3 {auth noauth priv}} message-processing {v1 v2c v3} [{volatile nonvolatile}] Description Enters the configuration mode Configures the SNMP target parameters. ParamName The parameter to be notified. Alphanumeric value with a maximum of 40 characters. UserName - Alphanumeric value with a maximum of 40 characters. Security model Use one of v1, v2c, v3. Use auth to enable authentication for the user. Use priv to enable encryption of packets. Message processing- Specifies the SNMP version for sending/receiving the parameter via a notification message. Use volatile if the value need not be stored in NVRAM. Step 3 end Step 4 show snmp targetparam Step 5 write startup-config Use nonvolatile if the value must be stored in NVRAM and available after restart. Exits the configuration mode. Displays the SNMP target parameters information. Optional step saves this SNMP configuration to be part of the startup configuration. The no snmp targetparams <ParamName> command deletes the specified SNMP target parameters information. The example below shows the commands used to configure the SNMP target parameters. Supermicro L2/L3 Switches Configuration Guide 23
24 SMIS(config)# snmp targetparams param4 user user4 security-model v2c message-processing v2c SMIS# end SMIS# show snmp targetparam Target Parameter Name: Internet Message Processing Model: v2c Security Model: v2c Security Name: None Security Level: No Authenitcation, No Privacy Target Parameter Name: param4 Message Processing Model: v2c Security Model: v2c Security Name: user4 Security Level: No Authenitcation, No Privacy Target Parameter Name: test1 Message Processing Model: v2c Security Model: v1 Security Name: None Security Level: No Authenitcation, No Privacy SNMP Notify Notify is used to specify the type of notifications to be sent to particular targets that are grouped under a particular tag. Follow the steps below to configure the SNMP Notification. Step Command Step 1 configure terminal Step 2 snmp notify <NotifyName> tag <TagName> type {Trap Inform} [{volatile nonvolatile}] Description Enters the configuration mode Configures the SNMP Notify information. NotifyName - Alphanumeric value with a maximum of 40 characters. n TagName Specifies a group of targets identified by this name. Alphanumeric Supermicro L2/L3 Switches Configuration Guide 24
25 value with a maximum of 255 characters. Type Notification can be Trap or Inform. Use volatile if the value need not be stored in NVRAM. Step 3 end Step 4 show snmp notify show snmp inform statistics Use nonvolatile if the value must be stored in NVRAM and available after restart. Exits the configuration mode. Displays the SNMP notification information and Inform statistics. Step 5 write startup-config Optional step saves this SNMP configuration to be part of the startup configuration. The no snmp notify <NotifyName> command deletes the specified SNMP notification. The example below shows the commands used to configure the SNMP notification. SMIS(config)# snmp notify PUBLIC tag tag1 type trap nonvolatile SMIS(config)# end SMIS# show snmp notif Notify Name: PUBLIC Notify Tag: tag1 Notify Type: trap Storage Type: Non-volatile Notify Name: iss Notify Tag: iss Notify Type: trap Supermicro L2/L3 Switches Configuration Guide 25
26 Notify Name: iss1 Notify Tag: iss1 Notify Type: trap Trap UDP Port The default UDP port for traps is 162. Supermicro switches provide an option for users to change this trap UDP port. Follow the steps below to configure the SNMP UDP port for traps. Step Command Step 1 configure terminal Step 2 snmp-server trap udp-port <port> Step 3 end Step 4 show snmp-server traps Description Enters the configuration mode Configures the SNMP UDP port for traps. Port UDP port for traps in the range Exits the configuration mode. Displays the SNMP traps information. Step 5 write startup-config Optional step saves this SNMP configuration to be part of the startup configuration. The no snmp-server trap udp-port command resets the SNMP UDP port to its default value of 162. The example below shows the commands used to configure the SNMP UDP port for traps. SMIS(config)# snmp-server trap udp-port 170 SMIS(config)# end SMIS(config)# show snmp-server traps SNMP Trap Listen Port is 170 Currently enabled traps: linkup, linkdown, Supermicro L2/L3 Switches Configuration Guide 26
27 Login Authentication Traps DISABLED Authentication Traps Traps can be generated when a user login authentication fails at the SNMP agent. In Supermicro switches, authentication traps are disabled by default. Follow the steps below to enable an SNMP authentication trap. Step Command Step 1 configure terminal Step 2 snmp-server enable traps snmp authentication Step 3 end Step 4 show snmp Description Enters the configuration mode Enables the SNMP authentication traps. Exits the configuration mode. Displays the SNMP information. Step 5 write startup-config Optional step saves this SNMP configuration to be part of the startup configuration. The no snmp-server enable traps snmp authentication command disables SNMP authentication traps. Link-up, Link-down traps are always enabled in the switch. The example below shows the commands used to enable the SNMP authentication traps. SMIS(config)# snmp-server enable traps snmp authentication SMIS# end SMIS(config)# show snmp-server traps SNMP Trap Listen Port is 162 Currently enabled traps: linkup,linkdown, Login Authentication Traps ENABLED. 1.8 Sub-Agent Supermicro switches can act as a Sub-Agent to another SNMP agent. SNMP Agent and Sub-Agent communication is via a protocol called AgentX. The Sub-Agent feature is disabled by default. Follow the steps below to configure an SNMP Sub-Agent. Supermicro L2/L3 Switches Configuration Guide 27
28 Step Command Step 1 configure terminal Step 2 enable snmpsubagent {master { ip4 <ipv4_address> ip6 <ipv6_address> } [port <number>] } Description Enters the configuration mode Configures the switch as SNMP Sub- Agent. ipv4_address IPv4 address of Sub- Agent ipv6_address IPv6 address of Sub- Agent Step 3 end Step 4 show snmp agentx information show snmp agentx statistics Step 5 write startup-config number UDP port number for SNMP message reception/transmission at Sub-Agent, in the range of Exits the configuration mode. Displays the SNMP Sub-Agent information. Optional step saves this SNMP configuration to be part of the startup configuration. An SNMP Agent must be disabled before enabling an SNMP Sub-Agent. The disable snmpsubagent command disables the SNMP Sub-Agent. The example below shows the commands used to enable the SNMP Sub-Agent. SMIS(config)# disable snmpagent SMIS(config)# enable snmpsubagent master ip SMIS(config)# end SMIS# show snmp agentx information Agentx Subagent is enabled TransportDomain: TCP Master IP Address: Master PortNo: 705 SMIS(config)# show snmp agentx statistics Tx Statistics Transmitted Packets: 1 Open PDU: 1 Index Allocate PDU: 0 Supermicro L2/L3 Switches Configuration Guide 28
29 Index DeAllocate PDU: 0 Register PDU: 0 Add Agent Capabilities PDU: 0 Notify PDU: 0 Ping PDU: 0 Remove Agent Capabilities PDU: 0 UnRegister PDU: 0 Close PDU: 0 Response PDU: 0 Rx Statistics Rx Packets: 0 Get PDU: 0 GetNext PDU: 0 GetBulk PDU: 0 TestSet PDU: 0 Commit PDU: 0 Cleanup PDU: 0 Undo PDU: 0 Dropped Packets: 0 Parse Drop Errors: 0 Open Fail Errors: 0 Close PDU: 0 Response PDU: SNMP Configuration Example PC SNMP Manager Switch - SNMP Agent Figure SNMP-2 SNMP Configuration Example Configure the following requirements on a switch acting as an SNMP agent as shown above in Figure SNMP-2. 1) SNMP v1/v2 Community 2) SNMP view to include SNMP statistics OID. 3) SNMP UDP port Supermicro L2/L3 Switches Configuration Guide 29
30 4) Enable authentication traps 5) SNMP Target address and parameters for notification #configure SNMP community SMIS(config)# snmp community index testcom name testcom security none SMIS(config)# end #configure SNMP view SMIS(config)# snmp view view mask included SMIS(config)# end #configure SNMP Trap port SMIS(config)# snmp-server trap udp-port 190 SMIS(config)# end #Enable SNMP authentication trap SMIS(config)# snmp-server enable traps snmp authentication SMIS(config)# end #configure SNMP Target address information SMIS(config)# snmp targetaddr tgt1 param stat SMIS(config)# end #configure SNMP Target parameters information SMIS(config)# snmp targetparams stat user user1 security-model v1 message-processing v1 SMIS(config)# end # Check the running-configuration for accuracy SMIS# show running-config Building configuration... Switch ID Hardware Version Firmware Version 0 SBM-GEM-X3S+ (B4-01) vlan 1 ports gi 0/1-24 untagged ports ex 0/1-3 untagged exit snmp-server trap udp-port 190 snmp community index testcom name testcom security none volatile snmp view view included volatile Supermicro L2/L3 Switches Configuration Guide 30
31 snmp targetaddr tgt1 param stat volatile snmp targetparams stat user user1 security-model v1 message-processing v1 volatile snmp-server enable traps snmp authentication interface vlan 1 ip address exit #Display all configured values SMIS# show snmp community Community Index: NETMAN Community Name: NETMAN Security Name: none Context Name: Transport Tag: Community Index: PUBLIC Community Name: PUBLIC Security Name: none Context Name: Transport Tag: Community Index: testcom Community Name: testcom Security Name: none Context Name: Transport Tag: SMIS# show snmp viewtree View Name: iso Subtree OID: 1 Subtree Mask: 1 View Type: Included Storage Type: Non-volatile View Name: view1 Subtree OID: Supermicro L2/L3 Switches Configuration Guide 31
32 Subtree Mask: View Type: Included View Name:Rrestricted Subtree OID: 1 Subtree Mask: 1 View Type: Excluded Storage Type: Non-volatile SMIS# show snmp-server traps SNMP Trap Listen Port is 190 Currently enabled traps: linkup, linkdown, Login Authentication Traps ENABLED. SMIS# show snmp targetaddr Target Address Name: tgt1 IP Address: Tag List: Parameters: stat SMIS# show snmp targetparam Target Parameter Name: internet Message Processing Model: v2c Security Model: v2c Security Name: none Security Level: No Authenitcation, No Privacy Target Parameter Name: stat Message Processing Model: v1 Security Model: v1 Security Name: user1 Security Level: No Authenitcation, No Privacy Supermicro L2/L3 Switches Configuration Guide 32
33 Target Parameter Name: test1 Message Processing Model: v2c Security Model: v1 Security Name: none Security Level: No Authenitcation, No Privacy # Save this SNMP configuration. SMIS# write startup-config Building configuration, Please wait. May take a few minutes... [OK] SMIS# Supermicro L2/L3 Switches Configuration Guide 33
L2 / L3 Switches. Remote Network Monitoring (RMON) Configuration Guide
L2 / L3 Switches Remote Network Monitoring (RMON) Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no
How To Configure Link Aggregation On Supermicro Switch 2 And 3 (Lan) On A Microsoft Vlan 2 And Vlan 3 (Vlan) (Lan 2) (Vlans) (Lummer) (Powerline) (
L2 / L3 Switches Link Aggregation Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility
L2 / L3 Switches. Link Layer Discovery Protocol (LLDP) Configuration Guide
L2 / L3 Switches Link Layer Discovery Protocol (LLDP) Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes
Supermicro Server Monitoring with SuperDoctor 5 and SCOM 2012
Supermicro Server Monitoring with SuperDoctor 5 and SCOM 2012 User s Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes
Configuring Simple Network Management Protocol (SNMP)
Configuring Simple Network Management Protocol (SNMP) This chapter describes the Simple Network Management Protocol (SNMP), SNMP Management Information Bases (MIBs), and how to configure SNMP on Cisco
SNMP Version 3. Finding Feature Information. Information About SNMP Version 3. Security Features in SNMP Version 3
The feature provides secure access to devices by authenticating and encrypting data packets over the network. Simple Network Management Protocol version 3 (SNMPv3) is an interoperable, standards-based
L2/L3 Switches. System. Configuration Guide
L2/L3 Switches System Configuration Guide Revision 1.0 The information in this USER S MANUAL has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies
SBI-7125B-T1 Blade Module RAID Setup Procedure
SBI-7125B-T1 Blade Module RAID Setup Procedure Revison 1.0 SBI-7125B-T1 Blade Module RAID Setup Procedure The information in this User s Manual has been carefully reviewed and is believed to be accurate.
Switch Quick Configuration CLI Guide for
Switch Quick Configuration CLI Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release : 1.0d 1 /
SNMP Simple Network Management Protocol
SNMP Simple Network Management Protocol Simple Network Management Protocol SNMP is a framework that provides facilities for managing and monitoring network resources on the Internet. Components of SNMP:
Configuring SNMP Monitoring
17 CHAPTER This chapter describes how to configure SNMP traps, recipients, community strings and group associations, user security model groups, and user access permissions. Note Throughout this chapter,
SNMP in Cisco IOS. The minimum you should know
The minimum you should know SNMP Framework Manager Agent MIB i.e. Cisco Works (or better something that really works) Software component on managed device Collection of objects/variables a manager can
Switch Web GUI Quick Configuration Guide for
Switch Web GUI Quick Configuration Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release: 1.0c 1
Simple Network Management Protocol
CHAPTER 4 This chapter gives an overview of (SNMP). It contains the following sections: Overview, page 4-1 SNMP Versioning, page 4-2 SNMP and Cisco Unified CM Basics, page 4-3 SNMP Basic Commands, page
Chapter 38 Simple Network Management Protocol (SNMP)
Chapter 38 Simple Network Management Protocol (SNMP) Introduction... 38-3 Network Management Framework... 38-3 Structure of Management Information... 38-5 Names... 38-6 Instances... 38-6... 38-7 Access...
Simple Network Management Protocol
Simple Network Management Protocol This document describes how to configure the Simple Network Management Protocol (SNMP). This document consists of these sections: Understanding SNMP, page 1 Configuring
Configuring SNMP CHAPTER7
CHAPTER7 This chapter describes how to configure Simple Network Management Protocol (SNMP) to query the Cisco Application Control Engine (ACE) module for Cisco Management Information Bases (MIBs) and to
Dotworkz NVR Series User Manual. Rev 1.26
Dotworkz NVR Series User Manual Rev 1.26 The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that
securitymodel who securityname com2sec secname ipsource community default group groupname model secname v1 v2c usm
SNM ver. 1.7 SNMP v3 - p. 1/36 SNMP Version 3 More about and USM Nick Urbanik 2003, 2005 Copyright Conditions: Open Publication License (seehttp://www.opencontent.org/openpub/) Avoid
A Guide to Understanding SNMP
A Guide to Understanding SNMP Read about SNMP v1, v2c & v3 and Learn How to Configure SNMP on Cisco Routers 2013, SolarWinds Worldwide, LLC. All rights reserved. Share: In small networks with only a few
Configuration Commands. SNMP System Commands. engineid. 7950 XRS System Management Guide Page 303 SNMP. Syntax [no] engineid engine-id
SNMP Configuration Commands SNMP System Commands engineid Syntax [no] engineid engine-id Context config>system>snmp Description This command sets the SNMP engineid to uniquely identify the SNMPv3 node.
Table of Contents. Table of Contents
Table of Contents Table of Contents Chapter 1 System Management Configuration... 1 1.1 File Management Configuration... 1 1.1.1 Managing the file system... 1 1.1.2 Commands for the file system... 1 1.1.3
> Simple Network Management Protocol (SNMP) for ERS 8600 Technical Configuration Guide. Ethernet Routing Switch. Engineering
Ethernet Routing Switch 8600 Engineering > Simple Network Management Protocol (SNMP) for ERS 8600 Technical Configuration Guide Enterprise Business Solutions Document Date: April 4, 2007 Document Number:
Brocade Product Training
Brocade Product Training Introducing SNMP Web-based Training Brocade Education Services Page 1-1 Objectives Describe SNMP basics: terminology and concepts Describe the need for SNMP Describe the advantages
UEFI BIOS Recovery Instructions
UEFI BIOS Recovery Instructions USER S GUIDE Revision 1.0a The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any
An Overview of SNMP on the IMG
An Overview of SNMP on the IMG Description SNMP The SNMP provides a way to control and monitor a variety of equipment using one network management protocol. To do this, SNMP uses a number of common Management
Tech Note Cisco IOS SNMP Traps Supported and How to Conf
Tech Note Cisco IOS SNMP Traps Supported and How to Conf Table of Contents Cisco IOS SNMP Traps Supported and How to Configure Them...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1
Web-based Management Utility
MicroBlade Web-based Management Utility USER S MANUAL Revison.0b MicroBlade Web-based Management Utility USER S MANUAL The information in this USER S MANUAL has been carefully reviewed and is believed
eco PDU PE Series SNMP Settings User Instructions
eco PDU PE Series SNMP Settings User Instructions www.aten.com NRGence User Help User Information Online Registration Be sure to register your product at our online support center: International North
SNMP and Network Management
SNMP and Network Management Nixu Oy Nixu Ltd PL 21 (Mäkelänkatu 91) 00601 Helsinki, Finland tel. +358 9 478 1011 fax. +358 9 478 1030 [email protected] http://www.nixu.fi Contents Network Management MIB naming
Cisco CMTS Router MIB Overview
CHAPTER 1 This chapter provides an overview of the Cisco Cable Modem Termination System (CMTS) router. This chapter contains the following topics: MIB Description, page 1-1 Benefits of MIB Enhancements,
Remote Management. Vyatta System. REFERENCE GUIDE SSH Telnet Web GUI Access SNMP VYATTA, INC.
VYATTA, INC. Vyatta System Remote Management REFERENCE GUIDE SSH Telnet Web GUI Access SNMP Vyatta Suite 200 1301 Shoreway Road Belmont, CA 94002 vyatta.com 650 413 7200 1 888 VYATTA 1 (US and Canada)
SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)
1 SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP) Mohammad S. Hasan Agenda 2 Looking at Today What is a management protocol and why is it needed Addressing a variable within SNMP Differing versions Ad-hoc Network
INTRODUCTION TO SNMP AND MIB
INTRODUCTION TO SNMP AND MIB SESSION 2004 Cisco Systems, Inc. All rights reserved. 1 Objectives This is an introduction on SNMP and MIB For beginners Will not delve into the technical details SNMPv3: only
SolarWinds Technical Reference
SolarWinds Technical Reference Implementing SNMPv3 Why SNMPv3?... 3 SNMPv3 Security... 4 General Implementation... 6 SolarWinds Product-Specific Implementation... 7 SolarWinds SNMPv3 input mapped to IOS..
SNMP Reference Manual
SNMP Reference Manual SNMP Reference Manual Rel. 2.0.0 Copyright 2004 Allied Telesis All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis.
Vanguard Applications Ware Basic Protocols. SNMP/MIB Management
Vanguard Applications Ware Basic Protocols SNMP/MIB Management Notice 2008 Vanguard Networks 25 Forbes Boulevard Foxboro, Massachusetts 02035 (508) 964-6200 All rights reserved Printed in U.S.A.. Restricted
Comparison of SNMP. Versions 1, 2 and 3
Comparison of SNMP 1 Comparison of SNMP Versions 1, 2 and 3 Eddie Bibbs Brandon Matt ICTN 4600-001 Xin Tang April 17, 2006 Comparison of SNMP 2 During its development history, the communities of researchers,
Table of Contents. Overview...2. System Requirements...3. Hardware...3. Software...3. Loading and Unloading MIB's...3. Settings...
Table of Contents Overview...2 System Requirements...3 Hardware...3 Software...3 Loading and Unloading MIB's...3 Settings...3 SNMP Operations...4 Multi-Varbind Request...5 Trap Browser...6 Trap Parser...6
Intel PCH RAID Configuration Utility
Intel PCH RAID Configuration Utility USER S MANUAL Revision 1.0a The information in this User s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for
ireasoning SNMP Agent Simulator User Guide
ireasoning SNMP Agent Simulator User Guide Copyright 2002-2012 ireasoning Inc, All Rights Reserved. The information contained herein is the property of ireasoning Inc. This document may not be copied,
Simple Network Management Protocol (SNMP) version 4.13
Simple Network Management Protocol (SNMP) version 4.13 Typeset in L A TEX from SGML source using the DocBuilder-0.9.8.5 Document System. Contents 1 SNMP User s Guide 1 1.1 SNMP Introduction......................................
Configuring SNMP. 2012 Cisco and/or its affiliates. All rights reserved. 1
Configuring SNMP 2012 Cisco and/or its affiliates. All rights reserved. 1 The Simple Network Management Protocol (SNMP) is part of TCP/IP as defined by the IETF. It is used by network management systems
Network Management. Jaakko Kotimäki. Department of Computer Science Aalto University, School of Science. 21. maaliskuuta 2016
Jaakko Kotimäki Department of Computer Science Aalto University, School of Science Outline Introduction SNMP architecture Management Information Base SNMP protocol Network management in practice Niksula
ITEC310 Computer Networks II
ITEC310 Computer Networks II Chapter 28 Network Management: Department of Information Technology Eastern Mediterranean University Objectives 2/60 After completing this chapter you should be able to do
TELE 301 Network Management
TELE 301 Network Management Lecture 20: Management Tools and Protocols Haibo Zhang Computer Science, University of Otago TELE301 Lecture 20: Management tools and protocols 1 What is Network Management?
Network Management & Monitoring Introduction to SNMP
Network Management & Monitoring Introduction to SNMP Network Startup Resource Center www.nsrc.org These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license
Network FAX Driver. Operation Guide
Network FAX Driver Operation Guide About this Operation Guide This Operation Guide explains the settings for the Network FAX driver as well as the procedures that are required in order to use the Network
Simple Network Management Protocol (SNMP) version 3.4
Simple Network Management Protocol (SNMP) version 3.4 Typeset in L A TEX from SGML source using the DOCBUILDER 3.3.2 Document System. Contents 1 SNMP User's Guide 1 1.1 SNMP Introduction......................................
ireasoning SNMP Agent Builder User Guide
ireasoning SNMP Agent Builder User Guide Copyright 2002-2006 ireasoning Inc, All Rights Reserved. The information contained herein is the property of ireasoning Inc. This document may not be copied, reproduced,
VOIP-211RS/210RS/220RS/440S. SIP VoIP Router. User s Guide
VOIP-211RS/210RS/220RS/440S SIP VoIP Router User s Guide Trademarks Contents are subject to revise without prior notice. All trademarks belong to their respective owners. FCC Warning This equipment has
Broadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
Simple Network Management Protocol
Simple Network Management Protocol Chu-Sing Yang Department of Electrical Engineering National Cheng Kung University Outlines Basic Concepts Protocol Specification Transport-Level Support SNMP Group Practical
HARTING Ha-VIS Management Software mcon 3000 Next Generation. User Manual SNMP
HARTING Ha-VIS Management Software mcon 3000 Next Generation User Manual SNMP All brand and product names are trademarks or registered trademarks of the owner concerned. 3 rd Edition 2013, revised 10/13
Configuring and Monitoring Hitachi SAN Servers
Configuring and Monitoring Hitachi SAN Servers eg Enterprise v5.6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of this
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
CA Spectrum and CA Performance Center
CA Spectrum and CA Performance Center Integration Guide CA Spectrum Release 9.3 - CA Performance Center r2.3.00 This Documentation, which includes embedded help systems and electronically distributed materials,
Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide
BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide Version 5.0 rev 1 Advantech Corp., Ltd. Table of Contents BwSNMP Advantech WebAccess to SNMP Agent (Simple
This section describes how to set up, find and delete community strings.
SNMP V1/V2c setup SNMP community strings, page 1 SNMP notification destinations, page 4 SNMP community strings Set up community string This section describes how to set up, find and delete community strings.
The ABCs of SNMP. Info Sheet. The ABC of SNMP INTRODUCTION. SNMP Versions
The ABCs of SNMP INTRODUCTION One of the numerous acronyms from the Internet world is SNMP which stands for Simple Network Management Protocol. Of course, anything termed simple is suspect. SNMP is an
SNMP SECURITY A CLOSER LOOK JEFFERY E. HAMMONDS EAST CAROLINA UNIVERSITY ICTN 6865
SNMP SECURITY A CLOSER LOOK JEFFERY E. HAMMONDS EAST CAROLINA UNIVERSITY ICTN 6865 NOVEMBER 25, 2013 SNMP SECURITY 2 ABSTRACT As a Network Monitoring System Administrator I have gained a substantial amount
Network Monitoring & Management Introduction to SNMP
Network Monitoring & Management Introduction to SNMP Mike Jager Network Startup Resource Center [email protected] These materials are licensed under the Creative Commons Attribution-NonCommercial
The Discovery Wizard now provides the ability to create SNMP Setups that can be selected for individual discoveries. An SNMP Setup specifies:
Using Discovery 1/3 Using Discovery Open the Discovery application by clicking Discovery in the Task Bar, selecting Discovery from the Applications menu, or by clicking the Discovery icon in the Topology
Configuring SNMP and using the NetFlow MIB to Monitor NetFlow Data
Configuring SNMP and using the NetFlow MIB to Monitor NetFlow Data NetFlow is a technology that provides highly granular per-flow statistics on traffic in a Cisco router. The NetFlow MIB feature provides
Operations Manager: Network Monitoring
Operations Manager: Network Monitoring Phil Bracher Chris Maiden Agenda Network Monitoring Overview Network Monitoring Features Out of the box discovery, monitoring, dashboards & reporting. Server to network
SNMP Test er Manual 2015 Paessler AG
SNMP Test er Manual 2015 Paessler AG All rights reserved. No parts of this work may be reproduced in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping,
Management, Logging and Troubleshooting
CHAPTER 15 This chapter describes the following: SNMP Configuration System Logging SNMP Configuration Cisco NAC Guest Server supports management applications monitoring the system over SNMP (Simple Network
Best Practices. SNMP-Based Network Management on Devices Running the Junos OS. Published: 2014-01-10. Copyright 2014, Juniper Networks, Inc.
Best Practices SNMP-Based Network Management on Devices Running the Junos OS Published: 2014-01-10 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 USA 408-745-2000 www.juniper.net
7750 SR OS System Management Guide
7750 SR OS System Management Guide Software Version: 7750 SR OS 10.0 R4 July 2012 Document Part Number: 93-0071-09-02 *93-0071-09-02* This document is protected by copyright. Except as specifically permitted
SNMP -overview. Based on: W.Stallings Data and Computer Communications
SNMP -overview Based on: W.Stallings Data and Computer Communications Network Management -SNMP Simple Network Management Protocol (not so simple ) Dominant standardized network management scheme in use
Monitoring Traffic manager
Monitoring Traffic manager eg Enterprise v6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of this document may be reproduced
Configuring and Monitoring Citrix Branch Repeater
Configuring and Monitoring Citrix Branch Repeater eg Enterprise v5.6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of
Network Monitoring with SNMP
Network Monitoring with SNMP This document describes how SNMP is used in WhatsUp Gold v11 and provides examples on how to configure performance, active, and passive monitors. Introduction SNMP (Simple
HP Load Balancing Module
HP Load Balancing Module Load Balancing Configuration Guide Part number: 5998-2685 Document version: 6PW101-20120217 Legal and notice information Copyright 2012 Hewlett-Packard Development Company, L.P.
Know the signs of potential problems. Prevent problems before they occur. This unit contains the following three lessons:
Unit 6 Router Management Overview Description With today s networks growing exponentially, management is a key to quality of network performance. People depend on their networks and performance issues
Simple Network Management Protocol (SNMP) Primer
Xerox Multifunction Devices July 22, 2003 for the user Simple Network Management Protocol (SNMP) Primer Purpose This document introduces the history, purpose, basic functionality and common uses of SNMP
Network Monitoring and Management Recommendations Best Practice Document
Network Monitoring and Management Recommendations Best Practice Document Produced by AMRES led working group on network monitoring (AMRES BPD 101) Authors: Esad Saitović and Ivan Ivanović February 2011
SNMP Agent Plug-In Help. 2011 Kepware Technologies
2011 Kepware Technologies 2 Table of Contents Table of Contents 2 4 Overview 4 Agent Setup 5 General 6 Network Interfaces 6 Communication 7 Agent Actions 9 System Objects 10 System Objects Description
Monitoring QNAP NAS system
Monitoring QNAP NAS system eg Enterprise v6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of this document may be reproduced
SNMPv3 in Practice Workshop
SNMPv3 in Practice Workshop 1 Objectives Configure Agents to use SNMPv3 Cisco IOS Juniper JunOS Net-SNMP Configure Managers for SNMPv3 Net-SNMP CLI Tools Net-SNMP Trap Daemon OpenNMS 2 More Objectives
CLIREFERENCEGUI WebSmartSwi
DE S1 2 1 0 1 0 / 2 8 CLIREFERENCEGUI DE WebSmartSwi t ch Table of Contents Table of Contents... i About This Guide... 1 Copyright and Trademarks... 1 1 INTRODUCTION... 2 To connect a switch via TELNET:...
P330-ML Version 4.5 Release Notes
Avaya P330-ML Version 4.5 Release Notes 1. Introduction This document contains information related to the Avaya P332G-ML, P332GT-ML and P334T-ML stackable switches that was not included in the User's Guide.
MIB Explorer Feature Matrix
MIB Explorer Feature Matrix Lite Pro Android Standards and Protocols Supported SNMPv1 (RFC 1157), SNMPv2c (RFC 1901/1905), and SNMPv3 (RFC 3412-3417). Transport Protocols UDP, TCP, and. All transport protocols
SNMP Driver Help. 2015 Kepware, Inc.
2015 Kepware, Inc. 2 Table of Contents Table of Contents 2 5 Overview 5 Channel Setup 6 Device Setup 7 Device ID Selection 7 Scan Mode 8 Communication Parameters 9 SNMP V3 Security 12 MIB Import Settings
Simple Network Management Protocol (SNMP)
Simple Network Management Protocol (SNMP) Copyright 1997-2015 Ericsson AB. All Rights Reserved. Simple Network Management Protocol (SNMP) 5.2.1 December 15, 2015 Copyright 1997-2015 Ericsson AB. All Rights
Hands-On SNMPv3 Tutorial & Demo Manual
Hands-On SNMPv3 Tutorial & Demo Manual NuDesign Technologies, Inc. rev A04 1 www.ndt-inc.com Table of Contents 1. INTRODUCTION WHY SNMPV3 4 1.1 Community based security 4 1.2 User-Based Security (USM)
Simple Network Management Protocol
CS 556 - Networks II Internet Teaching Lab (MCS B-24) Simple Network Mgmt Protocol (SNMP) Simple Network Management Protocol What you will learn in this lab: Details of the SNMP protocol. Contents of a
Managing and Monitoring Network Management Features
Managing and Monitoring Network Management Features This feature module describes how to monitor, manage and deploy a variety of network management features, including Cisco Active Network Abstraction
Introduction to Simple Network Management Protocol (SNMP)
Introduction to Simple Network Management Protocol (SNMP) Simple Network Management Protocol (SNMP) is an application layer protocol for collecting information about devices on the network. It is part
Configuring and Monitoring SiteMinder Policy Servers
Configuring and Monitoring SiteMinder Policy Servers eg Enterprise v5.6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part
User s Guide. SNMPWEBCARD Firmware Version 12.06.0062 through 12.06.0065 Revision A
WARRANTY REGISTRATION: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty User s Guide SNMPWEBCARD Firmware Version 12.06.0062 through 12.06.0065 Revision A
Simple Network Management Pwnd. Information Data Leakage Attacks Against SNMP
Simple Network Management Pwnd Information Data Leakage Attacks Against SNMP Introduction Deral Heiland [email protected] [email protected] @Percent_X Matthew Kienow [email protected] @HacksForProfit
EXTENSIBLE AGENTS FACILITATE THE EXTENSION OF SNMP AGENTS WITH NEW MIB MODULES SEPARATE SNMP PROTOCOL ENGINE FROM MIB INSTRUMENTATION
UNIVERSITY OF TWENTE The SimpleWeb EXTENSIBLE AGENTS FACILITATE THE EXTENSION OF SNMP AGENTS WITH NEW MIB MODULES SEPARATE SNMP PROTOCOL ENGINE FROM MIB INSTRUMENTATION ALLOW DYNAMIC ADDITION OF NEW MIB
Technology Overview. Frequently Asked Questions: SNMP on Junos OS. Published: 2014-08-12. Copyright 2014, Juniper Networks, Inc.
Technology Overview Frequently Asked Questions: SNMP on Junos OS Published: 2014-08-12 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 USA 408-745-2000 www.juniper.net Juniper
Moxa EDS-SNMP OPC Server Pro User s Manual. www.moxa.com/product
Moxa EDS-SNMP OPC Server Pro User s Manual www.moxa.com/product Second Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. Moxa EDS-SNMP OPC Server Pro
Device LinkUP + Desktop LP Guide RDP
Device LinkUP + Desktop LP Guide RDP Version 2.1 January 2016 Copyright 2015 iwebgate. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval
SNMP Monitoring and SWG MIB
SNMP Monitoring and SWG MIB Secure Web Gateway Release 10.0 Manual Version 1.01 M86 SECURITY SNMP MONITORING AND SWG MIB 2010 M86 Security All rights reserved. 828 W. Taft Ave., Orange, CA 92865, USA Version
CA Nimsoft Monitor Snap
CA Nimsoft Monitor Snap Configuration Guide for SNMP data monitoring snmpcollector v1.1 series Legal Notices Copyright 2013, CA. All rights reserved. Warranty The material contained in this document is
Configuring and Monitoring Bluecoat AntiVirus
Configuring and Monitoring Bluecoat AntiVirus eg Enterprise v5.6 Restricted Rights Legend The information contained in this document is confidential and subject to change without notice. No part of this
