Blindside waterproofing is a
|
|
|
- Jade Cole
- 10 years ago
- Views:
Transcription
1 Blindside waterproofing is a system in which the belowgrade waterproofing membrane is temporarily at tached to the soil-retention system facing the excavation, prior to casting the concrete foundation against it. It is required where the exterior faces of foundation walls will be inaccessible. A common situation dictating blindside waterproofing is the proximity of adjacent property lines or other abutting structures that preclude excavation outside the foundation walls (Photo 1). Strictly defined, it is positive-side waterproofing, but a blindside waterproofing problem is sometimes solved by negativeside or integral waterproofing. 1 Water proofing under pressure slabs on grade is also a form of blindside waterproofing. This paper discusses blindside waterproofing and the pros and cons of the various types of membranes that are currently marketed in the United States for that use. It does not include those products manufactured for use on plazas and similar locations where the waterproofing system is not subjected to hydrostatic pressure. Nor does it include crystalline and similar coatings applied to the negative side of foundations and additives to cast-in-place concrete. Photo 1 Soil retention system to receive blindside waterproofing at zero lot line foundation. 6 INTERFACE HISTORICAL BACKGROUND Below-grade occupied spaces traditionally were provided to house heating systems and served as storage areas. 2 They were rarely deeper than one story. However, in the past 50 years, deeper basements were required for below-grade automobile parking and air-conditioning equipment, which became popular after World War II. Buildings in large cities were being built out to lot lines and fronted on streets crowded with below-ground utilities. Thus, applying waterproofing to the outboard side of foundations became impractical. Today s foundations are typically reinforced concrete. But prior to the turn of the nineteenth century, foundations were primarily constructed of stone several feet thick and frequently parged with cement on the inboard side. The water resistance of the parging was increased by adding iron filings and an oxidizing catalyst, which caused the iron to corrode and swell, compacting the parging. Limited moisture infiltration in these
2 stone foundations often occurred 3 but was not considered critical since the equipment located in the basement could tolerate dampness. However, when basements were constructed in areas with high water tables, more water-resistant construction was required to satisfy the demands of moisture-sensitive occupancies. The choice was either to construct a watertight basement with walls and slabs sufficiently strong to resist hydrostatic pressure or to provide a drainage system of sumps and pumps in order to reduce the water pressure. The proponents of the drainage system contended that the interest on the increased cost of constructing a hydrostatic pressureresistant basement was greater than the cost of providing sumps and operating the pumps. Frequently, the below-ground waterproofing system consisted of adding chemicals to the concrete to densify it by filling the voids. These additives consisted of finely ground sand, colloidal clays, or hydrated lime. Some additives, such as stearates and oil, were intended to repel the water. In 1910, the Engineering News reported, Oil in the amount of 10% by weight of the cement gives very satisfactory results and is economical, since oil costs about 6 to 7 cents per gallon or about 60 to 70 cents more per cubic yard of concrete. 4 The use of additives did not find unqualified acceptance. Kidder-Parker, in its 1945 Handbook, recounts a report published by ASTM Committee D08, circa 1927, regarding the permeability of concrete and methods used to render it waterproof. The committee report discusses the results of laboratory testing and information obtained from the field. It evaluates the addition of foreign substances and external treatments. The committee concluded that additives to concrete were of doubtful benefit, whereas protective coatings both bituminous, applied to the exterior faces of the concrete, and cementitious, applied to the interior face had proven to be efficacious. At the turn of the twentieth century, popular blindside waterproofing applications on zero lot line basements consisted of erecting drainage tiles against a brick soilretaining system, then covering them with bricks dipped in hot coal-tar pitch. (Asphalt bricks were also used and dipped in hot [unblown] asphalt.) Alternately, multiple layers of burlap or felt swabbed with hot pitch or asphalt would be applied over the tile and covered with bricks. The concrete foundation wall was then cast against it Figure 1 Historical blindside waterproofing system. (Figure 1). The boilers, which were located in the basement, kept the foundation walls warm enough to keep the coal-tar pitch soft and enable it to reseal when shifting soils caused seams to open. Good workmanship was critical to the successful waterproofing envelope, but perfection was not always achieved. Con se quently, the prudent designer did not solely rely on the waterproofing system, but installed a drainage system under the waterproofed slab that conducted infiltrating water to a sump from which it was pumped to a sewer. Unfortunately, most municipal sewage treatment plants refuse to accept the discharge of subsurface water, or they accept it on a limited basis. BLINDSIDE WATERPROOFING MEMBRANES Generally, blindside membranes can be divided into two categories: Attached Nonattached Attached types are those that are intended to bond mechanically or adhesively to the concrete after it is cast against them. Nonattached types are those that are faced with a granular bentonite 6 compound or a hydrophilic polymer, which is intended to swell when in contact with water and form an impermeable watertight gel between the soil and the concrete or a looselaid thermoplastic sheet. Prior to 2000, there were only a handful of manufacturers that produced membranes specifically aimed at the blindside waterproofing market. Most of these products were either bentonite-clay systems or one-ply or built-up membranes designed to adhere to the concrete cast against them. Adhesion was obtained chemically or by concrete mechanically engaging fibers. The use of blindside waterproofing increased as more buildings were constructed in heavily populated areas that precluded the luxury of extending the soil retention system sufficiently beyond the foundation to permit application on the positive side of foundation walls. This prompted manufacturers of positive-side waterproofing membranes to enter the field and established blindside waterproofing manufacturers to develop new products. Currently, these include bentonite claybased compounds and hydrophilic polymers laminated to EIP, HDPE, and geotextiles; a self-adhering SBS laminated to a polyester fleece; an adhesive-surfaced HDPE; a polymer-modified asphalt emulsion; and a butyl alloy laminated to TPO. Current producers of blindside water- I NTERFACE 7
3 proofing market one or more of these: A sheet applied to the soil retention system consisting completely or in part of bentonite that will create a water-impermeable gel between it and the concrete that is cast against it. A water-impermeable sheet applied to the soil retention system that will reattach itself to concrete cast against it and thus prevent leak water migration. A sheet applied to the soil retention system that is both water-impermeable and contains bentonite or hydrophilic polymer-based compounds and will prevent leak water from reaching the concrete. The sheet may or may not be designed to reattach itself to the concrete cast against it. A cold-applied, two-component polymer-modified asphalt emulsion. All of these systems are intended to facilitate leak detection by limiting the migration of leak water between the membrane and the concrete. BENTONITE-BASED MEMBRANES Older bentonite clay systems, such as sprayed and trowelled-on applications and clay-filled kraft paperboard panels, have generally been abandoned by their producers in favor of bentonite encapsulated in geotextiles or bentonite laminated to thermoplastic sheets. These were introduced to overcome the disadvantages of the panels and sprayed-on applications that failed when the bentonite was washed away by flowing water. However, the newer products did not completely solve the problem of failure when the soil retention assembly developed voids and neglected to provide the requisite confinement. BENTONITE/THERMOPLASTIC LAMINATED MEMBRANES The thermoplastic laminated products sought to correct bentonite clay erosion by introducing a sheet membrane as a first line of defense and utilizing the gel-forming bentonite bonded to it to prevent water that infiltrated the seams from coming in contact with the concrete. The thermoplastic sheets alone did not qualify as a satisfactory blindside waterproofing membrane because they lacked the ability to prevent leaking water from migrating laterally between the concrete and the 8 INTERFACE membrane. This was to be accomplished by the bentonite, but it was only effective when sufficient pressure was permanently maintained between the substrate and the membrane to confine the bentonite gel. Karim Allana reported on a HDPE/bentonite failure that resulted from moisture that deformed wood lagging. 7 Currently, granular bentonite compounds laminated to HDPE thermoplastic sheets are being marketed, one with an additional geotextile facing the concrete, which is intended to resist hydration on vertically applied installations but not to bond to concrete. Photo 2 Bituminous membrane installed under pressure slab and boarded-out lagging. BENTONITE/GEOTEXTILE MEMBRANES These products encapsulate bentonite between layers of woven and nonwoven polypropylene. The bentonite is intended to swell when hydrated, and one product is faced with a geotextile that is reported to form a mechanical bond with the concrete cast against it. With the exception of the products faced with geotextiles, the bentonite membranes rely on the principle that watertightness can be obtained by maintaining permanent compression between the soil retention system and the concrete foundation. This enables the swelling clay to develop sufficient pressure to prevent water from reaching the concrete and migrating laterally. Critical to this is the effectiveness of the soil retention system to provide solid, void-free backing. Such is not always the case in the real world, where settlement, intermittent pressures, corrosion, and rot exist and combine to erode the structural integrity of the substrate. This may reduce the confining pressure below that is required to ensure watertightness. The fact that this is not easily achieved is noted by Gibbons and Towle, 8 who point out that the West Coast practice of using shot-crete as a soil retention system does not provide the necessary confining pressure to allow bentonite platelets to create a waterproof layer. BITUMINOUS MEMBRANES The use of multiple-ply coal-tar pitch membranes has been so restricted by VOC regulations that their use today is virtually nonexistent. They have been replaced by a two-ply, chloroprene-modified asphalt membrane and an SBS-modified asphalt sheet surfaced with a polyester fleece. The older chloroprene-modified membrane is reported to bond to the concrete as it is softened by the heat of hydration of the cement when the concrete is cast against it. The newer membranes consisting of polyester fleece or nonwoven fabric laminated to a modified asphalt are also intended to mechanically bond to the concrete cast against them. One manufacturer markets a spray-applied, two-component, modifiedasphalt emulsion that is claimed to chemically bond to concrete cast against it. The membrane is marketed as a gas vapor barrier system (Photo 2). The older, two-ply membrane has a 45 year track record, whereas the newer, SBS membranes have yet to establish one. The asphalt emulsion has a somewhat limited resistance to hydrostatic pressure, compared with the other two. THERMOPLASTIC AND HDPE ADHESIVE-SURFACED MEMBRANES One of the oldest single-ply blindside waterproofing membranes consists of an HDPE sheet surfaced with an adhesive. A recently introduced system consists of a TPO membrane surfaced with a butyl adhesive. Both membranes are intended to chemically bond to the concrete cast against them. Seams are sealed with pressure-sensitive tape. The HDPE/adhesive sheet manufacturer does not recommend it for use in a blind-
4 side application where the adhesive face will receive shotcrete. 9 The HDPE sheet is thick and does not easily conform to changes in plane. The manufacturer recommends using a selfadhering rubberized asphalt sheet; a twocomponent, trowel-applied, asphalt-modified urethane; and tapes. This transition has proven to be the most vulnerable part of the system and must be carefully designed and installed (Photo 3). The TPO/butyl sheet is a self-adhered 22- and 30-mil TPO that is more flexible. The seams are lapped and sealed with factoryapplied adhesive. It is yet to be demonstrated whether this seam performs satisfactorily when the 30-mil sheet is turned up the foundation and concrete is cast against it. SEAMS As with all sheet membranes, seams are the Achilles heel at which water infiltration is most likely to occur. Movement of the substrate can open so-called bentonite pressure seams that are simply lapped or mechanically fastened and depend on soil compression to keep them watertight. Taped seams improve the integrity of the seam since they are better able to resist the shrinkage that is common with HDPE. Heat-fused seams are far superior but more costly. Nevertheless, heat-fused seams offer the greatest resistance to seam failure caused by differential movement between the concrete and the substrate. Probably the one location where seams become critical is the transition from the horizontal to vertical and the vertical re- Photo 4 Boarded-out lagging. Photo 3 HDPE sheet membrane on mud slab and lagging. entrant angle. The thermoplastic sheets are usually thick and can be quite stiff in colder climates. They are often thicker for use under pressure slabs than those applied to the lagging. At the horizontal/vertical reentrant angle, most manufacturers details suggest that the horizontal membrane be turned up the wall a certain distance and lapped by the vertically applied membrane. This often results in tenting because the sheet is too stiff to conform to the right angle. The adhered seam is also turned up. When the concrete foundation wall is cast against the coved corner, the seams are susceptible to rupture or disbonding. This is exacerbated at the transitions where the slab meets the interior and exterior corners of the foundation, columns, and pile caps. With sheet thicknesses that exceed 60 mils, good, tight corners are virtually impossible to fabricate in one piece. Joints of thermoplastic sheets that are welded or that use a combination of more flexible sheets and tapes and with a liquid component usually perform better than those that rely on adhesives or bentonite pressure laps. ATTACHMENT TO SUBSTRATE A basic premise of blindside waterproofing is that the membrane must be installed securely, albeit temporarily, to the soil retention system. It should resist displacement from sagging wet concrete and be capable of spanning small voids, step-offs, and other surface irregularities with rupturing or disbanding seams. It should not be secured so tenaciously that displacement of the soil-retention system tears it away from the cured concrete foundation. Seismic events, corrosion, erosion warping, and decay must be taken into consideration. Moreover, it should provide uniform support free of voids that can localize pressures and rupture the membrane. Soil-retention systems usually consist of lagging or shotcrete but also may include sheet piling. Lagging is usually installed with 1-in or greater joints between timbers and must be overlaid to form a smooth, I NTERFACE 9
5 solid surface to receive the blindside membrane. This is the role of plywood sheathing, drainage composites, protection boards, and rigid insulation (Photo 4). The attachment of the membrane to the soil retention system must be assumed to be temporary and that the fasteners will corrode and/or the substrate into which they are driven will rot away or disintegrate. Eventually, the lagging will no longer provide a uniform, structurally sound support. If the retention system shifts, rots away, twists, cups, or disintegrates, the membrane may be vertically or laterally displaced or the resultant voids may fail to provide the requisite pressure required by bentonite, and its watertight integrity will be threatened. 10 All three systems rely on watertight seams. Sheets containing bentonite depend on the initial and continuing integrity of the soil retention system to maintain void-free solid surfaces that will be capable of resisting water infiltration. Blindside membranes that depend on adhesion to the concrete share this problem of unstable substrates but not to the same degree. Shifting, settlement, or similar lateral movement of the soil-retention system can shear the tenuous bond between the membrane and the concrete, tearing it at fasteners or open seams between the sheets. Often, this can be minimized by introducing several layers of materials between the membrane and the lagging. Common components are plywood, protection boards, drainage composites, and low-density expanded polystyrene, which have been used separately or in combinations. Differential movement between the membrane and lagging can be absorbed by adhering these components rather than mechanically fastening them or allowing the lowdensity expanded polystyrene to shear internally. However, some fasteners may be required to resist the shear forces that result from placing concrete. Photo 5 Bentonite membrane under pressure slab. cally or adhesively or to swell in contact with water to form a water-impermeable gel. The membranes are installed over a compacted gravel subgrade or an unreinforced concrete mud slab. The gravel must be well compacted and free of voids or pockets that would permit the membrane to bridge. The mud slab must also be free of voids, ridges, or surface irregularities that would not provide uniform support (Photo 5). Neither the mud slab nor compacted gravel is intended to provide support for the membrane for the life of the building. The gravel will eventually settle or be washed away, and the mud slab will disintegrate. When this occurs, the membrane must remain firmly adhered to the pressure slab or the bentonite remain in compression. In this respect, the bonded membrane offers superior water resistance. However, the ability to provide a satisfactory mechanical or adhesive bond can be compromised during the normal course of construction. Sheets that depend on mechanically engaging the concrete with the geotextile fibers can have those fibers compressed by construction traffic and material storage to the extent that they can no longer provide a satisfactory bond. Sheets that depend on chemical adhesion can lose their adhesion when coated with a film of dirt that concentrates in puddles over the surface. Both problems can often be avoided by casting a 2- to 3-in layer of concrete over the membrane as soon as possible after each section is completed. This will protect the membrane, and its surface can then be raked to bond to the pressure slab. This has the added advantage that reinforcing chairs, pipe supports, and the like will be supported on the concrete fill rather than directly on the membrane. THE DESIGNER S DILEMMA Unlike roofing, below-grade waterproofing is intended to perform satisfactorily for the life of the building. Once concrete is cast against the membrane, it is essentially inaccessible for repairs. This poses a challenge for the designer who is interested in exploring some of the newer blindside waterproofing systems but lacks the comfort of a long track record. Note that warranties do not provide for removal and replacement of overburden should the membrane fail. Moreover, the physical and logistical MEMBRANES UNDER PRESSURE SLABS Membranes for use under pressure slabs are similar to those used for blindside waterproofing on foundations a blindside waterproofed foundation rotated 90 degrees. They are intended to bond to the underside of the pressure slab cast over them mechani- Photo 6 Grout injection. 10 INTERFACE
6 restraints of removing 3 to 5 ft of concrete to access the membrane make this procedure impractical. How, then, can the prudent designer venture into the unknown world of new blindside waterproofing systems or even older proven systems that are dressed up in new clothes? Since it is as unrealistic to select a waterproofing membrane that will perform for an infinite life as it is to select one for zero probability of failure, a certain amount of risk must be accepted as inevitable. There is always cause for concern when specifying newer systems that lack a reasonably long track record, both in membrane performance and the installer s familiarity with installation procedures. The selection and application of the wrong waterproofing system can result in leaks and substantial financial consequences. Fortunately, there are some welldeveloped methods of remediation when water begins to flow down the foundation walls or bubble up through the joints in the floor slab. Reverting back to negative-side waterproofing systems is a tried-and-true method of halting infiltration. Today there are crystalline waterproofing compounds that have proven to be effective for face grouting. They can be applied to large areas of prepared concrete or used to fill cracks and joints. However, this remedy may be defeated by inaccessibility where equipment is installed against a foundation wall or at intersecting partitions (Photo 6). Alternately, when large areas of concrete walls and floor slabs are inaccessible, cracks and joints can be injected with hydrophilic urethane or acrylates. Hydro phobic urethane can also be injected behind the walls or under the slab to create a chemical grout curtain. Bentonite slurry (Bentogrout ) can also be injected behind foundation walls and is particularly appropriate where bentonite-based membranes were installed. Having these methods of remediation available should allay some of the concerns about using one of the newer blindside waterproofing systems. Additional protection can be provided by other methods that will minimize water infiltration. Since most basement leaks occur at construction joints, the use of hydrophilic waterstops at these locations should be mandatory wherever hydrostatic pressure exists. Where occupancies are particularly sensitive to leakage, reinjectable hoses should also be provided in joints. Avoiding horizontal construction joints is also desirable whenever possible since it is difficult to ensure that the intersection of horizontal and vertical waterstops can be made watertight. Finally, nothing is as good as quality assurance during the installation. The membrane manufacturer should be intimately involved with every step of the installation, beginning with the initial product selection. Following prewaterproofing meetings, he should conduct a class in situ to instruct the applicators and work out the details. Treatment of tie-back heads, form spreaders, well points, and other penetrations should be detailed on the shop drawings and means and methods resolved in the field prior to beginning work. RECOMMENDATIONS Failures in blindside waterproofing applications may not be avoided by using one of the products introduced to the market in the last ten years, but the prudent designer can take precautions to reduce the risks and provide a long-term watertight basement. Select products from producers who have experience in manufacturing I NTERFACE 11
7 and installing blindside waterproofing systems. Involve the manufacturer s technical forces early and throughout the initial phases of the installation. Don t rely on stock details. Prepare exhaustively detailed construction and shop drawings that will address penetrations, plane changes, tiebacks, walers, rakers footblocks, pile caps, construction joints, and other allied issues. Hold mandatory preconstruction meetings with the excavation contractor to explore all the means and methods of soil retention. This includes the location of well points. (Well points are never indicated on drawings; but if they are located too close to the foundation walls, adequate flashing becomes extremely difficult.) Provide waterstops at all construction joints in foundation walls and pressure slabs on grade. Hydro philic rubbers, with or without bentonite fillers, have mostly replaced PVC and other glands. Consider adding reinjectable hoses where pressures are high and occupancies are sensitive to moisture. Advise the owner that some leaking cannot always be prevented but that there are established means and methods to stop the water infiltration, should it occur. Where dampness threatens applied finishes, consider applications of coatings specifically designed to reduce the emissivity to acceptable levels. Use a mud slab under pressure slabs rather than compacted gravel. Carefully detail sheet plane transitions. Use cants or an assembly of sheets, tape, and the liquid component of the system rather than relying on the manufacturer s details. Since lathers erecting reinforcing and form spreaders often damage in-place waterproofing, the waterproofing contractor s superintendent should inspect the membrane prior to casting each lift of concrete. ENDNOTES 1. Some of the pitfalls to using negative-side waterproofing are the lack of positive water vapor control and the discontinuities that occur at Waterproofing System Below-Grade intersecting shear walls and inter- Applications, Failures, and Solu mediate suspended slabs. tions, Sealant, Waterproofing, and 2. Kidder-Parker, Architects and Restoration Institute, 2010 Winter Builders Handbook, 18th Edition, Technical Meeting, South Beach 1945, John Wiley & Sons, New York, Miami, FL, Feb , NY. 8. Daniel G. Gibbons and Jason L. 3. Ibid. Towle, Waterproofing Below-Grade 4. Ibid. Shotcrete Walls, The Construction 5. Properties of membranes have been Specifier, March obtained from the latest literature 9. For shotcrete applications, the published by W.R. Grace, Carlisle HDPE/adhesives manufacturer Coatings and Waterproofing, Trem - markets a system consisting of a co, Soprema, Cetco, W.R. Meadows, sheet membrane coupled with a and Laurenco. polymer-mesh reinforced cavity cov 6. The term bentonite, used through- ered with a geotextile that is postout this paper, refers to sodium ben- filled through injection ports with tonite clay and polymer-modified hydrophilic grout. compounds thereof. 10. Ibid. 7. Karim Allana, Bentonite Composite Justin Henshell, FAIA, FASTM Justin Henshell has been a registered architect for over 58 years, is licensed in six states, and holds a certificate from the National Council of Architectural Registration Boards. He is a Fellow of the American Institute of Architects and ASTM International. He is the recipient of the 2010 William C. Cullen Award, the Walter C. Voss Award, and RCI s William C. Correll Award. Henshell is a member of ASTM Committees D08 on roofing and waterproofing (past chair of Sub committee D08.20 on roofing membrane systems), C15 on masonry units, and E06 on performance of building constructions. He serves on the International Council for Building Research Studies & Documentation, Commission W086 on building pathology. Mr. Henshell has authored and presented close to 50 technical articles and papers in the United States, Canada, and Europe on a variety of subjects related to construction materials, particularly roofing, waterproofing, flashing, and masonry. He is the principle author of an ASTM standard on waterproofing design and a coauthor of an NCARB monograph on built-up roofing. He is also the author of The Manual of Below-Grade Waterproofing Systems. Paul Buccellato,AIA, FATSM Paul Buccellato is a registered architect in six states and holds a certificate from the National Council of Architectural Registration Boards. He is a member of the American Institute of Architects; Construction Specifications Institute; and RCI, Inc.; and is a Fellow of ASTM. He is a member of Committee D08 on roofing and waterproofing, where he serves as chair of Subcommittee D08.20 on roofing membrane systems. He is also a member of Committee C15 on masonry units. Mr. Buccellato has authored a number of technical papers on waterproofing and roofing and three ASTM standards on roofing, and has lectured at Brookdale Community College, NJ. He is coauthor of an NCARB monograph on built-up roofing. Buccellato has written and presented papers for RCI, Inc.; the National Roofing Contractors Association; and ASTM. He is member of RCI s Education Committee, its Registered Waterproofing Consultant Examination Subcommittee, and chair of its Registered Exterior Wall Consultant Examination Subcommittee. 12 INTERFACE
INVESTIGATING AND REMEDIATING LEAKS IN BELOW GRADE STRUCTURES AND UNDER PLAZAS
INVESTIGATING AND REMEDIATING LEAKS IN BELOW GRADE STRUCTURES AND UNDER PLAZAS JUSTIN HENSHELL, FAIA, FASTM HENSHELL & BUCCELLATO, RED BANK, NJ B U I L D I N G E N V E L O P E T E C H N O L O G Y S Y M
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
BELOW GROUND TANKING
BELOW GROUND TANKING Basement & Foundation Waterproofing Systems - What, Why & How By Paul Evans MBAV Specialist Contractor, Registered Building Practitioner Vice President Australian Institute of Waterproofing
BELOW GRADE & PLAZA WATERPROOFING SELECTION PROCESS
BELOW GRADE & PLAZA WATERPROOFING SELECTION PROCESS PAUL BUCCELLATO AIA, RWC HENSHELL & BUCCELLATO, RED BANK, NJ B U I L D I N G E N V E L O P E T E C H N O L O G Y S Y M P O S I U M O C T O B E R 2 0
Essential Performance Attributes of Preapplied waterproofing
Essential Performance Attributes of Preapplied waterproofing Craig Boucher, LEED AP Grace Construction Products 62 Whittemore Ave., Cambridge, MA 02140 Phone: 617-498-4429 Fax: 617-498-4419 E-mail: [email protected]
High Performance PSA in Sheet Membrane in Water Protection
High Performance PSA in Sheet Membrane in Water Protection Xia Cao, Senior R&D Chemist, W. R. Grace, Cambridge MA 02140 Jyoti Seth, Strategic Program Leader, W. R. Grace, Cambridge MA 02140 Concrete is
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
constructive solutions Fosroc total waterproofing protection of below-ground structures
constructive solutions Fosroc total waterproofing protection of below-ground structures Our profile Since the company s beginnings over 50 years ago, Fosroc has developed into an International leader in
R E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
The AQUAFIN Approach to Concrete Repair
Concrete Repair Building Product Systems Waterproofing & Concrete Restoration Decorative Coatings Moisture Vapor Remediation & Flooring Injection Grouting The AQUAFIN Approach to Concrete Repair www.aquafin.net
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
MATERIALS. Table 1 Mortar Proportions by Volume (Ref. 12)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY BASEMENT WALL CONSTRUCTION TEK 3- Construction (200) Keywords:
A. This Section includes rubberized asphalt sheet membrane waterproofing systems.
SECTION 07110 SHEET MEMBRANE WATERPROOFING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
Waterproofing below-ground with Proofex Engage. constructive solutions
Waterproofing below-ground with Proofex Engage constructive solutions Our profile Since the company s beginnings over 50 years ago, Fosroc has developed into an International leader in delivering Constructive
Sources A recent survey of leaking basements showed water comes from a variety of sources, but walls are the usual culprit: Occurrence of moisture
NEGATIVE SIDE WATERPROOFING»»»»»»»»»»»»»» NEGATIVE SIDE WATERPROOFING NEGATIVE SIDE WATERPROOFING NEGATIVE SIDE WATERPROOFING It s Possible to Waterproof Leaking Basements From the Inside By Basil Mewes
Water Damage & Repair
Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES
BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES ABOUT POLYGLASS U.S.A., INC. MODIFIED CEMENTS & ADHESIVES MASTICS ALUMINUM COATINGS EMULSIONS & PRIMERS PROTECTIVE COATINGS Polyglass manufactures
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
School Construction Authority Architecture & Engineering
SCOPING GUIDELINES 1.0 GENERAL GUIDELINES 2.0 BUILDING ENVELOPE SCOPING GUIDELINES 3.0 CATEGORIES AND COMPONENTS: The Flood Elimination/Below Grade Capital Category may include some or all of the following
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
Remedial Waterproofing of Basement
Remedial Waterproofing of Basement [Source:http://www.property-care.org/files/cop_structural_ waterproofing.pdf and http://www.foundation-repair-guide.com] 1.0 Introduction Remedial waterproofing of basement
Comment Form on Proposed Gut Rehabilitation Alternatives
Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to [email protected] by October 10 th, 2012 with the subject line
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
Shotcrete, a method of applying
Getting a waterproofing and drainage layer tough enough to stand up to shotcrete is a top priority because repairing the membrane after the fact is usually not an option. Water Barriers to Withstand Shotcrete
201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE
STRUCTURAL INSPECTION REPORT DRAFT 201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE TOWN OF PRESCOTT Date: November 2013 GENIVAR No.: 131-20617-00 2611 Queensview Drive, Suite 300, Ottawa,
ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING
DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings
STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope
FOUNDATIONS STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION Build a Better Home Details are critical when constructing a sound building foundation that will withstand water and control dampness.
What you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE
www.epdmroofs.org COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE By Ric Vitiello President Forensic Roof Consulting and Hail Damage Assessment Training www.benchmark-services.com
Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification
AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING Typical s Table of Contents: No. 4 5 6 7 8 9 0 External waterproofing of below ground concrete wall & slab Internal waterproofing of foundation
CREEK Technical Services, LLC
EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: Henry Company Report Issued February 20, 2013 999 North Sepulveda Blvd., Suite 800 El Segundo, CA 90245 (800) 486-1278 Manufacturing Plants: Quality
Concrete Waterproofing Systems. Integral Protection. www.tritonsystems.co.uk
Concrete Waterproofing Systems Integral Protection n Type B Integral Protection in accordance with BS 8102 (2009) n Unique chemical admix for waterproofing and protection of concrete n A complete and permanent
A Guide to Structural Waterproofing
A Guide to Structural Waterproofing Part One Waterproofing Protection For Below Ground Structures 1 2012 W. R. Grace & Co Benjamin J. Brooks Table of Contents Grace Around The World Reference Material
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
WATERTITE ADVICE - CONCRETE MASONRY UNIT BLOCK WALLS
Waterproofing & Construction Products Since 1974 Volume 2, Issue 3 - Concrete Masonry Unit Block Walls NEWSLETTER Bentonite WATERTITE ADVICE - CONCRETE MASONRY UNIT BLOCK WALLS Tired of waterproofing delays
Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training
Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick
Photo courtesy of Delta Stone, Heber City, UT Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick THIN VENEER INSTALLATION SYSTEMS PREMIUM BONDING MORTARS Premium PCL Stone
Waterproofing below-ground with Proofex Engage
Waterproofing below-ground with Proofex Engage Pre-applied waterproofing membrane conforming to the requirements of BS EN 13967:2004 and BS 8102:2009. Proofex Engage mechanically bonds to poured concrete,
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057. Lecturer: Jim Cahill
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057 Lecturer: Jim Cahill 29 th November 2011 TABLE OF CONTENTS SUMMARY 1 MAIN BODY SECTION
Please read the entire document before purchasing and installing any of these products
Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
A Case Study of waterproofing Strategies for a Typical Mat and Deep Foundation System
A Case Study of waterproofing Strategies for a Typical Mat Deep Foundation System Andrea B., PE, LEED AP BD+C; Stephen T., SE Simpson Gumpertz & Heger Inc. The Lmark @ One Market, Suite 600, San Francisco,
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses
WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.
WET/DAMP BASEMENTS PROBLEM. IS THIS BASEMENT LEAKING OR COULD WE HAVE ANOTHER PROBLEM? Water line arching up on wall in corners of basement. Water collecting on concrete floor starting in corners. ANSWER:
State of Connecticut Department of Public Health RADON PROGRAM
State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon
WATERPROOFING SikaProof -A TECHNOLOGY
SikaProof -A TECHNOLOGY content What is SikaProof -A? 6 How does it work? 8 Where can it be used? 0 What are the advantages of SikaProof -A? 2 How should it be installed? SikaProof -A system components
Waterproofing construction Joints
WaterproofingSystems Waterproofing construction Joints Area waterproofing Backing rod KÖSTER Joint Sealant FS-H KÖSTER FS Primer Contents Basics Connective, loadable and resilient: Joints in building construction
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
Moisture Mitigation for Concrete Slabs
Moisture Mitigation for Concrete Slabs A brief description of alternative methods for dealing with slab moisture problems By Peter A. Craig M oisture-related problems with floor coverings and coatings
The existing roof angle change terminations and flashings when sound and intact can be reused.
January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing
SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)
SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO) 1 Intent: The intent of trenchless sewer pipe Insertion is to rehabilitate the existing sewer
Basement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
MAPEI s Resfoam polyurethane products
MAPEI s Resfoam polyurethane products Manhole Rehabilitation System Water treatment facilities across the nation are squandering energy and capacity due to the unnecessary treatment of millions of gallons
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
Roofing Systems. New Applications / Re-Roofing / Maintenance
Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),
Moisture and Resilient Floor Covering
Moisture and Resilient Floor Covering Moisture related failures of resilient floor coverings installed over concrete have focused unfairly over the years on the premise that the flooring product itself
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.
Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them
Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps
Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure
Basements are Changing John Straube, Ph.D., P.Eng Basements: New & Retrofit Energy Efficient, Durable, Healthy Increasingly used as living space Not a root /coal cellar anymore! High quality space expected
Foundation Water Problems. An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures
Foundation Water Problems An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures This presentation was prepared and presented by Dwight Walker
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
Low-slope reroofing guidelines
Low-slope reroofing guidelines by Thomas Bollnow and Joan P. Crowe, AIA The NRCA Roofing and Waterproofing Manual, Fifth Edition, contains reroofing guidelines for steep- and low-slope roofing. The August
SECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.
SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.
What Causes Foundation Leaking?
A home's foundation has the odds stacked against it from the day it's built. When a home is excavated to make room for the foundation walls, space is left between the outer edge of the foundation wall
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
Section 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco
The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco Disclaimer: This guide contains general information on stucco installation and related materials. It is provided as a guide only and is
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
10DBMC International Conference On Durability of Building Materials and Components LYON [France] 17 20 April 2005
10DBMC International Conference On Durability of Building Materials and Components Wall Cladding System Durability Lessons Learned from the Premature Deterioration of Wood-Framed Construction Clad with
Foundation. Foundation
Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their
Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES
ARCHITECTURAL SPECIFICATIONS / CAD MODELS With more than 40 years of manufacturing high quality, innovative building products in the commercial and residential markets, Custom Building Products TVISTM
REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542
1.0 INTENT REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES 1.01 It is the intent of this specification to provide for the reconstruction of pipelines and conduits by the installation of a resin-impregnated
Lighthouse Engineering, L.L.C.
Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: [email protected] Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a
Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION
Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION The Condensation Process Condensation occurs when warmer moist air comes in contact with cold surfaces such as framing members, windows
SECTION 07550 - MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.
SECTION 07550 - PART I GENERAL 1.01 SECTION INCLUDES A. Vapor barrier (base ply); cover board at existing roof deck. B. Roof insulation at new roof deck. C. Modified bitumen membrane. D. Fluid applied
Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group
Weather Resistive Barriers: Building Science Makes a Case for Two Layers by Dave Olson Technical Services Manager, Fortifiber Building Systems Group Since water intrusion is among the most damaging problems
Soils, Foundations & Moisture Control
Soils, Foundations & Moisture Control Soil The top loose layer mineral and/or organic material on the surface of the Earth that serves as a natural medium for the growth of plants and support for the foundations
PERFORMANCE GUIDELINES
1. Foundation/Basement 17 PERFORMANCE GUIDELINES 1. FOUNDATION/BASEMENT 1.1 Efflorescence on concrete or masonry surfaces Efflorescence is the formation of a white crystalline or powdery deposit on the
Roof Systems Overview
Roof Systems Overview Cold Applied Built-Up Roofing Systems BURmastic Tremco s line of cold applied built-up roofing systems. BURmastic 200 Combines Tremco s expertise in asphalt blending technology with