2 BELOW GROUND TANKING Basement & Foundation Waterproofing Systems - What, Why & How By Paul Evans MBAV Specialist Contractor, Registered Building Practitioner Vice President Australian Institute of Waterproofing (AIW) Did you know that waterproofing represents 1.8% of a building s construction costs, but accounts for a whopping 83% of building defect complaints? Below Ground Waterproofing Overview I have compiled the following information based upon my personal experience as a Registered Building Practitioner specialising in waterproofing applications and with over 30 years in the construction industry. My aim is to inform about the choices of below ground tanking methods, factors involved when selecting waterproofing materials and hopefully by knowing this information may also help to identify experienced and knowledgeable applicators. I have witnessed some appalling mistakes in regard to waterproofing and in particular below ground systems. As a builder I truly believe below ground waterproofing is as important as your foundations supporting the entire structure. Without the combination of sound footings and waterproof structures a building will deteriorate rapidly. Unlike some other building components that might be designed to be replaced several times within the overall building service life, below grade systems need to be built to approximate overall service life. Below grade systems are often inaccessible for repairs and extremely costly if modifications or rectifications are necessary at a future date. 2
3 Below Ground Waterproofing Design & Planning Durability of design and materials is mandatory with below grade waterproofing systems. Or if not exactly neglected, below ground waterproofing is often treated with disregard and unbelievably sometimes even completely forgotten within the planning process in construction. In my opinion there are far too many architectural specifications which do not even include a below ground waterproofing package at the planning stage. Below ground waterproofing is one of those areas usually unseen and I am not sure if it is this out of sight, out of mind mentality, however it is an area of construction often neglected This may go some way to explain some of the hasty decisions made in relation to below ground tanking. Lack of planning has the potential to lead to some very expensive and time consuming future waterproofing rectification projects. Without due diligence and correct time and attention given to the task of planning the below ground waterproof system, corners maybe cut at the time of construction due to the necessity of on the fly decisions. It is critical to select the appropriate foundation waterproofing method as a caseby-case project and it is at the planning stage which is the appropriate time for these decisions. Below ground waterproofing is not a generic one size fits all scenario and design should be as required by the respective project. For below grade waterproofing design, the sole focus should not be on the initial cost of materials but rather consideration to the life cycle costs of various design options. This is especially important as costs to repair or replace systems that are buried can be exorbitant. The following section provides specific description of waterproofing materials and systems common in foundation walls and below grade building enclosure systems. 3
4 Waterproofing Membranes Waterproofing membrane systems are available as either post-applied or preapplied products for use in either positive-side, negative-side, or blind-side applications. Positive-side waterproofing systems are post-applied to the surface of the element that is directly exposed to moisture, typically the exterior side of the foundation wall. Negative-side waterproofing systems are post-applied to the surface of the element opposite the surface exposed to moisture, typically the interior of the foundation wall. Blind-side waterproofing systems are pre-applied to the area where the concrete element will be placed that is directly exposed to moisture. Positive-side systems are available in numerous materials and forms. Negative systems are generally limited to cementitious systems. A blind-side system designed by F.E.W Waterproofing is called F.E.W CLOAKING SYSTEM which is a polyethylene pin punched fabric draped and bonded at the base of footing or top edge of slab to beyond the height of site cut. This cloak of fabric is then sprayed with LIQUID RUBBER to completely saturate the fabric forming one continuous seamless barrier or a flexible waterproof screen which is then encouraged into place once the wall has been placed. Design is specific to each project. Waterproofing membranes can be categorized into four (4) types: Extract from Institute of Building Sciences 1. Fluid-Applied Systems these systems include urethanes, rubbers, plastics and modified asphalts. Fluid-applied membranes are applied in liquid form and cure to form one monolithic seamless membrane. For foundation wall applications, typical cold applied fluid applied systems are approximately 60 mils in thickness. Some systems include reinforcing mesh embedded into the liquid. Hot applied, rubberized asphalt systems can be 125 mils to 180 mils thick, plus embedded 60 mil neoprene sheets. Spray Applied Elastomeric Liquid Membrane 7
5 2. Sheet-Membrane Systems Sheet membranes used in foundation wall applications include thermoplastics, vulcanized rubbers, and rubberized asphalts. The thickness of these systems varies from 20 to 120 mils. If heatwelded seaming is employed and loose-hung membranes are tough and protected from damage by protection board, they may be effective waterproofing materials, but if a leak occurs, the leak will be difficult to locate and correct due to the loose application of the waterproofing layer in those cases. It is always better to have a continuously fully bonded and adhered waterproofing layer to reduce the potential for lateral moisture migration beneath the membrane. Heat Applied Sheet Membrane 3. Bentonite Clays these systems include composite sodium bentonite systems with HDPE liners and geotextile fabrics, which are more common and more effective than the traditional systems. Bentonite clays act as waterproofing by swelling when exposed to moisture thus becoming impervious to water. This swelling can be 10 to 15 percent of the thickness of the base material. Bentonite is, therefore, most effective when properly confined so the product can swell to fill voids and so that it cannot be washed away! Clay panels and geotextile sheets are popular for use in blind-side waterproofing applications such as on retaining earth systems and elevator and sump pits. 8
6 If Bentonite clay is unconfined, it can shrink upon drying, creating gaps that undermine waterproofing characteristics Cementitious Systems these systems contain Portland cement and sand combined with an active waterproofing agent. These systems include metallic (metal oxide), crystalline, chemical additive, and acrylic modified systems. The latter two should not be used as waterproofing except for the most noncritical conditions. The first two systems can be applied as negative-side or positive-side waterproofing. Even these systems should only be considered for use as a secondary (backup) waterproofing to a positive-side waterproofing system, unless they are used with special details provided by a waterproofing expert which are beyond the scope of what are usually provided by system manufacturers. Below Ground Waterproofing installation - General Guidelines Weather plays a large part in the success or otherwise with waterproofing installation. This needs to be appreciated and understood. Inclement weather will adversely affect the below ground waterproofing system during installation. Generally wet seasons are very difficult to achieve successful waterproofing. Planning and timing the below ground waterproofing installation around climatic conditions can be problematic. Waterproofing should be applied a minimum of 50 mm above the finished grade, and then applied to a point 300mm below the top surface of the interior slab ( base of footing) on a constant grade. 9
7 Typically, the waterproofing membrane is wrapped over a masonry brick shelf, or up behind the finish exterior materials at grade so that it may be terminated and shingle lapped by the weather barrier. When the membrane is wrapped over masonry ledges, care must be taken to coordinate with masonry ties and thru-wall flashings. Where grade slopes down along an exterior wall, the waterproofing membrane will step down incrementally so that it continues to protect the below grade, occupied space. If the exterior wall materials will not protect the waterproofing at grade, base flashings should be used to protect the waterproofing from ultraviolet (UV) radiation exposure - IF THE MEMBRANE IS NOT UV STABLE. These flashings are usually stainless steel to resist corrosion in contact with grade soils and moisture. Protecting the Waterproof Membrane from Damage - Protection Board Protection Boards are used to protect waterproofing membranes from damage. Most damage comes from backfill materials containing sharps and or rubbish. However unfortunately (and sadly) we often find damage has been caused by the contractors and sub-contract trades, such as electricians/plumbers/landscapers/data cable or TV cable installers etc, cutting holes in the finished membrane to pass a wire/pipe, etc through a wall. Some trades don t even try to seal the penetration, others try and fail - very few get it right! The message here is to plan ahead and ensure any penetration is done before or is above the membrane height. The most commonly used protection board in Australia is a Polypropylene Copolymer extruded sheet commonly known as Core Flute. Other materials sometimes used as protection layers are extruded polystyrene rigid board insulation, cement sheet or prefabricated synthetic drainage layers. F.E.W Waterproofing recommend, use and install and also supply an Australian made product called ARMA BLUE. 10
8 Arma-Blue is a roll of flexible 3mm thick poly-woven fabric bonded to a foam impact resisting core. The back side is sticky backed or peel and stick adhesive which prevents stone, debris, grit, etc getting between the protection board and membrane and causing damage to the membrane, resulting in leaks. In general, using prefabricated composite drainage board directly against certain waterproofing membranes as a protection layer is not recommended. Although the composite board may have a polyethylene sheet on the membraneside, this sheet is often cut, damaged, or missing. If installed, soil pressures can cause the "dimples" in the drainage core to displace or damage the waterproofing membrane. Additionally, the composite cores have sharp corners that can cut the waterproofing membrane during installation or backfill operations. Therefore, we always recommend a protection layer such as ARMA BLUE between the waterproofing membrane and the drainage layer. 11
9 Waterstops Waterstops should be utilized at construction joints in below grade walls, footings, slabs, and other elements where a waterproof system is required. Waterstop systems provide a secondary barrier to the passage of water across these construction joints. Waterstops are manufactured products available in a wide range of configurations and sizes. Common materials include polyvinyl chloride (PVC), neoprene, expanding sodium bentonite and thermoplastic rubber. Although not as common, pre-installed permeable grout injection waterstops may also be considered. Typically constructed with flexible PVC, permeable grout injection tubes are installed in construction joints and are injected with grout only if leakage is observed. In some cases, the tubes may also be re-injected if leakage persists. Injection ports/sites are typically accessed from the building interior. Common areas of concern for waterstops are at corners and laps in the materials. These areas must be properly detailed and installed to be effective. In general, the manufacturer's standard instructions should be followed. If PVC is used, corners and laps should be heat welded and properly inspected. Drainage Pipe Agricultural Systems (AG) or Aggie Pipe Drainage pipes, typically 100mm or 150mm in diameter, used in below grade systems are primarily made of corrugated PVC or polyethylene. PVC and polyethylene pipes are available in smooth or corrugated configurations and are slotted on the bottom half of their cross-section to allow water infiltration. A good quality pipe is essential so it will not crush under the weight of backfill. Based on extensive excavation and waterproofing experience, it has been found that corrugated PVC drain tile piping can collapse under the weight of backfill, and the preference is to use stiffer PVC pipe if possible. All Agricultural piping should be laid at the lowest point where water will flow and then graded to a pit for discharge. Backfill with an aggregate stone such as ¼ minus blue-metal, scoria, etc, which is laid onto a filter fabric covering the AG pipe. The fabric should be wrapped around and over the drain to try to prevent fine soils from filling the drain pipe. Ensure a slope or fall to drainage system. AG systems should be designed to be installed with some slope to ensure that the water moves toward the silt pit for connection to the storm water system or collection tanks. 12
10 By Paul Evans MBAV Specialist Contractor, Registered Building Practitioner, Vice President Australian Institute of Waterproofing (AIW) Managing / Director Phone: Building Services Australia. F.E.W Waterproofing 13
NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
R E S I D E N T I A L H O U S I N G
HL 252 Rev. April 1997 R E S I D E N T I A L H O U S I N G CONTROLLING EXTERNALWATER PROBLEMS FOR RESIDENCES I II III IV V Lot Drainage Gutter Water Management Foundation Waterproofing Floor Slab Waterproofing
Building Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
High Performance PSA in Sheet Membrane in Water Protection
High Performance PSA in Sheet Membrane in Water Protection Xia Cao, Senior R&D Chemist, W. R. Grace, Cambridge MA 02140 Jyoti Seth, Strategic Program Leader, W. R. Grace, Cambridge MA 02140 Concrete is
Comment Form on Proposed Gut Rehabilitation Alternatives
Comment Form on Gut Rehabilitation Alternatives Name: Organization: Email: Instructions Submission: Please submit this form to [email protected] by October 10 th, 2012 with the subject line
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
State of Connecticut Department of Public Health RADON PROGRAM
State of Connecticut Department of Public Health RADON PROGRAM Scope The Connecticut Department of Public Health (DPH) Radon Program is providing this information for contractors who decide to build radon
What you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS
NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS The (NRDCA) has prepared this document to provide customers and installers information that the industry
STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope
FOUNDATIONS STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION Build a Better Home Details are critical when constructing a sound building foundation that will withstand water and control dampness.
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057. Lecturer: Jim Cahill
ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R00060057 Lecturer: Jim Cahill 29 th November 2011 TABLE OF CONTENTS SUMMARY 1 MAIN BODY SECTION
Basement Moisture Problems
Foundations Foundation Purpose The purpose of a foundation is to distribute the weight of a structure securely into the ground. Engineering data regarding soil, rock and water conditions are used to design
Remedial Waterproofing of Basement
Remedial Waterproofing of Basement [Source:http://www.property-care.org/files/cop_structural_ waterproofing.pdf and http://www.foundation-repair-guide.com] 1.0 Introduction Remedial waterproofing of basement
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H
DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a
Sources A recent survey of leaking basements showed water comes from a variety of sources, but walls are the usual culprit: Occurrence of moisture
NEGATIVE SIDE WATERPROOFING»»»»»»»»»»»»»» NEGATIVE SIDE WATERPROOFING NEGATIVE SIDE WATERPROOFING NEGATIVE SIDE WATERPROOFING It s Possible to Waterproof Leaking Basements From the Inside By Basil Mewes
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8 with PCS unit segmental retaining wall
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
Ver. 2. Guide to. Inspecting Residential Brick Veneer
Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan
Roofing Systems. New Applications / Re-Roofing / Maintenance
Roofing Systems New Applications / Re-Roofing / Maintenance New Roof Installation In terms of the design and installation of an original roofing system (in conjunction with the construction of a new building),
Foundation Water Problems. An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures
Foundation Water Problems An Overview and Discussion of some Causes and Cures for Water Infiltration into Basements and Foundation Structures This presentation was prepared and presented by Dwight Walker
SECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
School Construction Authority Architecture & Engineering
SCOPING GUIDELINES 1.0 GENERAL GUIDELINES 2.0 BUILDING ENVELOPE SCOPING GUIDELINES 3.0 CATEGORIES AND COMPONENTS: The Flood Elimination/Below Grade Capital Category may include some or all of the following
Membrane for tunnels and underground construction
System Platon Membrane for tunnels and underground construction Drainage Protection Waterproofing Dry and healthy buildings The Isola history quality through innovation CONTENT The Isola History Air Gap
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
Asphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
Secondary Containment Comparison ATI Ultra COAT vs HDPE
When choosing a secondary containment system it must be chosen based on its ability to withstand long term contact with the natural elements (weather), whatever the tanks hold (unrefined oil, fuels, acids,
The AQUAFIN Approach to Concrete Repair
Concrete Repair Building Product Systems Waterproofing & Concrete Restoration Decorative Coatings Moisture Vapor Remediation & Flooring Injection Grouting The AQUAFIN Approach to Concrete Repair www.aquafin.net
Section 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
SikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
CONCRETE SEGMENTAL RETAINING WALL SYSTEM
CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Vintage TM unit segmental retaining wall (SRW)
BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012
BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR MARCH 2003 REVISED JUNE 13, 2012 Prepared in cooperation with the Building Inspectors Association of Southeastern Wisconsin www.biasew.net 1 BEST MANAGEMENT
Waterproofing membranes are a critical component
Below-Grade Residential: Drainage Boards & Footing Drains Waterproofing membranes are a critical component for keeping basements dry, but they re only half the solution. In most areas of the country, a
Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure
Basements are Changing John Straube, Ph.D., P.Eng Basements: New & Retrofit Energy Efficient, Durable, Healthy Increasingly used as living space Not a root /coal cellar anymore! High quality space expected
What Causes Foundation Leaking?
A home's foundation has the odds stacked against it from the day it's built. When a home is excavated to make room for the foundation walls, space is left between the outer edge of the foundation wall
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses
Renovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
The Perfect Fit For Metal Retrofit
D u r o - S h i e l d M e t a l R e t r o f i t R o o f i n g S y s t e m The Perfect Fit For Metal Retrofit Lock out leaks. Lock in your investment. Has time caught up with your metal roof? There are
WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.
WET/DAMP BASEMENTS PROBLEM. IS THIS BASEMENT LEAKING OR COULD WE HAVE ANOTHER PROBLEM? Water line arching up on wall in corners of basement. Water collecting on concrete floor starting in corners. ANSWER:
September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
MATERIALS. Table 1 Mortar Proportions by Volume (Ref. 12)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY BASEMENT WALL CONSTRUCTION TEK 3- Construction (200) Keywords:
Please read the entire document before purchasing and installing any of these products
Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection
NEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
WATERPROOFING FOR CONCRETE STRUCTURES
MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use
BLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
INSTALLATION GUIDE. americanwick.com 800.242.WICK (9425)
INSTALLATION GUIDE americanwick.com 800.242.WICK (9425) American Wick Drain SITEDRAIN prefabricated drainage products may be installed in a variety of civil construction applications including: retaining
DELTA Premium Moisture Management Systems for Foundations.
DELTA protects property. Saves energy. Creates comfort. DELTA Premium Moisture Management Systems for Foundations. DELTA Premium Moisture Management Systems provide the best protection for foundations.
Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
Residential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM
WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM SPECIFICATION NO. SMAA-2P-8xE UPGRADE SMOOTH SURFACE / CAP SHEET / SINGLE PLY 2 PLY POLYESTER REINFORCED ACRYLIC
Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.
Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that
ITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING
DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings
INVESTIGATING AND REMEDIATING LEAKS IN BELOW GRADE STRUCTURES AND UNDER PLAZAS
INVESTIGATING AND REMEDIATING LEAKS IN BELOW GRADE STRUCTURES AND UNDER PLAZAS JUSTIN HENSHELL, FAIA, FASTM HENSHELL & BUCCELLATO, RED BANK, NJ B U I L D I N G E N V E L O P E T E C H N O L O G Y S Y M
RIW STRUCTURESEAL. Structureseal is a highly effective waterproofing composite, of high strength green coloured geotextile, and sodium bentonite.
CI/SfB Tr9 L1415 November 2013 RIW STRUCTURESEAL is a highly effective waterproofing composite, of high strength green coloured geotextile, and sodium bentonite. BENEFITS l Pre-applied tanking systems
Low-slope reroofing guidelines
Low-slope reroofing guidelines by Thomas Bollnow and Joan P. Crowe, AIA The NRCA Roofing and Waterproofing Manual, Fifth Edition, contains reroofing guidelines for steep- and low-slope roofing. The August
EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
Essential Performance Attributes of Preapplied waterproofing
Essential Performance Attributes of Preapplied waterproofing Craig Boucher, LEED AP Grace Construction Products 62 Whittemore Ave., Cambridge, MA 02140 Phone: 617-498-4429 Fax: 617-498-4419 E-mail: [email protected]
Site Inspection Report
Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
WATERPROOFING SikaProof -A TECHNOLOGY
SikaProof -A TECHNOLOGY content What is SikaProof -A? 6 How does it work? 8 Where can it be used? 0 What are the advantages of SikaProof -A? 2 How should it be installed? SikaProof -A system components
Issue of the Guidelines on Prevention of Water Seepage in New Buildings
graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural
Avoiding Air Barrier Pitfalls
Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great
SECTION 724 PIPE CULVERTS
SECTION 724 PIPE CULVERTS 724.1 Description. This work shall consist of providing pipe or pipe arch of the diameter or shape designated, laid upon a firm bed and backfilled as specified. Where appropriate
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
Solving Persistent Moisture Problems and Moisture Damage
B etter buildings Solving Persistent Moisture Problems and Moisture Damage Summary This three-storey, 15-unit, 1,300 square metre (13,993 sq. ft) walk-up was built in 1958. In the 1980s, the building started
Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification
AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING Typical s Table of Contents: No. 4 5 6 7 8 9 0 External waterproofing of below ground concrete wall & slab Internal waterproofing of foundation
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
Water Damage & Repair
Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It
SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.
SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS Prepared by Risi Stone Systems Used by permission. 1-800-UNILOCK www.unilock.com FOREWORD This outline specification has been prepared for
Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology
2007 Pumper & Cleaner Environmental Expo International Wednesday February 7, 2007 Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology What is Cured-In-Place Pipe (CIPP)
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
Sewer Rehabilitation Design Requirements
Sanitary Sewer Overflow (SSO) Control and Wastewater Facilities Program Sewer Rehabilitation Design Requirements City of Baton Rouge/Parish of East Baton Rouge Department of Public Works Submitted by Prepared
PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT
PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT PREVENTING GROUNDWATER POLLUTION IS EVERYONE S JOB! Even if our drinking water comes from rivers, lakes, or reservoirs, we need to be mindful of
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
SPR PE Steel Reinforced Liner
ENGINEERED SOLUTIONS SPR PE Steel Reinforced Liner Reline Done Right Contech is your single source for rehabilitation of sanitary & storm sewers, culverts and bridges. Contech Engineered Solutions has
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)
Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
Division 9. SignaFlor Pad and Pour Flooring System
Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions
Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2
Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2 PROTECTING YOUR DURO-LAST ROOFING 3 Safety Measures 3 Inspection 3 Maintenance Program 4 Sealants 4 Drainage 4 Parapets Walls 4 Building
Roof Inspection. Summary Report
Phone: (561) 866 9956 www.real-estate-inspections.com Roof Inspection Summary Report Subject Property File Number: 05-15-RF-002 Inspector: Craig Milliken, PE CPM Real Estate Inspections, Inc. Date of Inspection:
DIVISION 4300 STORM DRAINAGE
DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES
Waterproofing below-ground with Proofex Engage. constructive solutions
Waterproofing below-ground with Proofex Engage constructive solutions Our profile Since the company s beginnings over 50 years ago, Fosroc has developed into an International leader in delivering Constructive
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction
METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS
This Document is designed to cover best practice installation procedures for a one layer torch applied sheet membrane system to basement walls. PRELIMINARY WORK Ensure that all surface preparation work,
Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.
Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them
1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance