Electron-Muon Ranger (EMR)

Size: px
Start display at page:

Download "Electron-Muon Ranger (EMR)"

Transcription

1 Electron-Muon Ranger (EMR) Status of EMR Project R.Asfandiyarov 1, P.Béné 1, R.Bloch 1, A.Blondel 1, D.Bolognini 3 F.Cadoux 1, S.Débieux 1, J-S.Graulich 1, C.Husi 1, D.Lietti 3, F.Masciocchi 1, L.Nicola 1, M.Prest 3, K.Rothenfusser 1, E.Vallazza 2, V.Verguilov 1 1 DPNC, Université de Genève, Switzerland 2 INFN, Sezione di Trieste, Italy 3 Università degli Studi dell Insubria and INFN, Sezione di Milano Bicocca, Italy MICE Video Conference, January 20, 2011 R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

2 EMR Design: Reminder Horizontal View EMR Design: Reminder Production Status Remaining Issues And Production Plans Characteristics 24 modules (X-Y planes) 48 planes 59 bars per plane 2832 bars 3m WLS fibers per bar 8.5 km WLS fibers single and 64-channel PMTs per plane channels R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

3 EMR Installation at RAL Most Recent CAD Model EMR Design: Reminder Production Status Remaining Issues And Production Plans R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

4 Current Production Status EMR Design: Reminder Production Status Remaining Issues And Production Plans 1021 bars glued with fibers, 18 planes assembled 2 modules equipped with fiber boxes and PMT connectors and installed on the test bench (see ) in order to speed up gluing of WLS fibers into bars a special device is being employed R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

5 Outer Box Assembly and Production EMR Design: Reminder Production Status Remaining Issues And Production Plans The Outer box will house the EMR planes and patch panels and will be used for transportation the bottom frame was manufactured and will be used to store completed modules R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

6 EMR Design: Reminder Production Status Remaining Issues And Production Plans Remaining Issues Patch panels on the outer box and cabling Polishing of PMT connectors is slow (done manually) Polishing machine will be used 1-2 bars are usually replaced during assembly due to broken fibers (we keep scintillator bars for future use) Production Plans All technicians will be available starting from February 1 module (2 planes) can be completed in about a week (if 118 bars were glued with fibers and assembled earlier) To complete all the modules at least six more months are needed, if everything goes as expected and all parts are available (see EMR Schedule). R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

7 New Front-End-Board (FEB) and Digitizer-Buffer-Board (DBB) Communication of DBB with VME Board New Electronic Boards for 64-channel PMT A new Front-End-Board (FEB) and Digitizer-Buffer-Board (DBB) were developed in order to read 64-channel PMT and store data during the MICE spill and subsequently transfer it to a dedicated VME board. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

8 Digitizer-Buffer-Board New Front-End-Board (FEB) and Digitizer-Buffer-Board (DBB) Communication of DBB with VME Board The DBB samples the 64 channels coming from FEB and transmits the event data upon request of the acquisition system. FPGA performs the sampling, data buffering, and data-flow control functions of the board. Internal memory of the FPGA is used to store data which is a collection of rising/falling edge timestamps which occurred on each channel during a spill. Six DBB are daisy-chained together with upstream and downstream links. The first DBB in each group is directly connected to the acquisition system. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

9 Mechanical Model of DBB and FEB New Front-End-Board (FEB) and Digitizer-Buffer-Board (DBB) Communication of DBB with VME Board A full mechanical model of DBB and FEB was produced in order to test the assembly and accessibility of different connectors when installed. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

10 Communication of DBB with VME Board New Front-End-Board (FEB) and Digitizer-Buffer-Board (DBB) Communication of DBB with VME Board 1 PC receives trigger and sends command to 8 VME controllers simultaneously 2 the VME controllers send command to six DBB asking to send data in sequential order 3 PC waits until all VME controllers finish receiving data from DBB and then reads the data from VME boards in sequential order R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

11 EMR Data Format Preliminary Assembly and Production New Front-End-Board (FEB) and Digitizer-Buffer-Board (DBB) Communication of DBB with VME Board Data format Format of control commands R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

12 Block Diagram of the Test Setup Description LED Pulser EMR mini-layer to test 1-ch. PMTs the test setup is used to setup DAQ system and test modules before transportation to RAL 2 modules are installed inside light tight box lower module is kept as a reference, upper one is exchanged analog signal from 64-ch. PMT is read from all boards, digital - only from the upper two R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

13 Assembly and Production Description LED Pulser EMR mini-layer to test 1-ch. PMTs all set up to perform tests with cosmics 2 CPUs, VME (read-out boards) and NIM (coincidence unit) crates LeCroy-1440 high voltage power supply for single- and 64-ch. PMTs scintillator triggers and silicon micro-strip detectors for track reconstruction and efficiency measurements (silicon detector is being repaired) LED pulser system for PMTs R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

14 LED Pulser System for PMTs Description LED Pulser EMR mini-layer to test 1-ch. PMTs the LED Pulser system (provided by P.Hanlet, D0 experiment, Fermilab, US) is used to monitor the performance of PMTs short pulses are feed into LED driver attached to light diffusers light is distributed through clear fibers directly to all PMTs PIN-diode is used in order to monitor light intensity (not operational yet) similar system but with 98 fibers will be used in the final setup R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

15 EMR mini-layer to test 1-ch. PMTs Description LED Pulser EMR mini-layer to test 1-ch. PMTs EMR mini-layer: short EMR scintillator bars with fibers fed into two 1-ch. PMTs purpose: to test 1-ch. PMTs and study their performance two scintillators in coincidence are used for the trigger signals from PMTs are analyzed by flash ADC (C.A.E.N. v1731) MIPs are used for calibration R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

16 Cosmics Spectrum at 1800 V Description LED Pulser EMR mini-layer to test 1-ch. PMTs R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

17 Monte Carlo Emulation EMR Simulation with Muon Beam Preliminary 250 MeV muon beam shot 2 m before the EMR green tracks - gammas, blue - muons, red - electrons R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

18 Summary Outlook Summary EMR Schedule June 2011 Production will resume in February Some mechanical issues needs to be addressed (patch panels, cabling etc.) Design of final electronic boards for 64-ch. PMT is finalized; routing and production is about to start Firmware for the new VME board must be written and communication protocol must be defined 4 new FEB (without buffer board) for cosmic tests will be equipped with MAROC-3 chips R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

19 Outlook Summary EMR Schedule June 2011 May 2011 First 6 DBB+FEB and 1 VME board should be ready. June fully equipped modules delivered to RAL for test run. After tests these will be shipped back to Geneva for further developments and final construction. November modules (48 planes) should be completed and tested. All DBB+FEB and VME boards should be produced and tested. EMR assembled in Geneva. December 2011 Full EMR installed in RAL - physics run. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

20 June 2011 Test run with 3 EMR modules at RAL Outlook Summary EMR Schedule June 2011 If EMR outer box is ready by April, we can send the 3 modules between April 18 and May 1 (ISIS break): Can we do that? Is there space to store the box? will be shipped separately. If EMR outer box is not ready by April, then we will send the 3 modules by June 13 and we will have two weeks to install it before the beam. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, January 20, / 20

Electron-Muon Ranger (EMR)

Electron-Muon Ranger (EMR) Electron-Muon Ranger (EMR) Status of EMR Project R.Asfandiyarov 1, P.Béné 1, R.Bloch 1, A.Blondel 1, D.Bolognini 3 F.Cadoux 1, S.Débieux 1, J-S.Graulich 1, C.Husi 1, Y.Karadzhov 1, D.Lietti 3, F.Masciocchi

More information

Electron-Muon Ranger (EMR)

Electron-Muon Ranger (EMR) Electron-Muon Ranger (EMR) Status of EMR Project R.Asfandiyarov 1, P.Béné 1, R.Bloch 1, A.Blondel 1, D.Bolognini 3, F.Cadoux 1, S.Débieux 1, J-S.Graulich 1, C.Husi 1, Y.Karadzhov 1, D.Lietti 3, F.Masciocchi

More information

Electron-Muon Ranger (EMR)

Electron-Muon Ranger (EMR) Electron-Muon Ranger (EMR) Ruslan Asfandiyarov MICE Video Conference April 11, 2013 Construction Construction quarter of the detector completed (12 planes) every plane tested (LED / Camera / image analysis)

More information

Progress status of EMR Assembly @ Geneva

Progress status of EMR Assembly @ Geneva Progress status of EMR Assembly @ Geneva MICE meeting July 7, 2010 1. 1. EMR EMR production status status (including reminder in in our our organization) 2. 2. EMR EMR outer outer box box (1 (1 rst rst

More information

Selecting Philips XP 2972 Photomultiplier Tubes for the Electron Muon Ranger (EMR)

Selecting Philips XP 2972 Photomultiplier Tubes for the Electron Muon Ranger (EMR) MICE-NOTE-DET-383 Selecting Philips XP 2972 Photomultiplier Tubes for the Electron Muon Ranger (EMR) Ruslan Asfandiyarov, Alain Blondel, Dasom Lee, Daniel Lievens DPNC, University of Geneva, Switzerland

More information

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca MICE detectors and first results M. Bonesini Sezione INFN Milano Bicocca I will speak of the installed beamline PID detectors (TOFes, CKOVs, KL) and only shortly of EMR (to be built)/ the trackers (tested

More information

Progress status of EMR Assembly @ Geneva

Progress status of EMR Assembly @ Geneva Progress status of EMR Assembly @ Geneva MICE meeting March 25-26, 2010 1. 1. EMR EMR production status status 2. 2. EMR EMR simulations (FEA (FEA studies) 3. 3. EMR EMR @ RAL RAL University of Geneva:

More information

EMR project Overview

EMR project Overview EMR project Overview MICE Collaboration Meeting RAL, May 31, June 3-2009 1. 1. EMR EMR conceptual design design 2. 2. Mechanical envelope 3. 3. Pending issues issues & outlook outlook University of Geneva:

More information

Electron-Muon Ranger (EMR)

Electron-Muon Ranger (EMR) Electron-Muon Ranger (EMR) Digitization and Reconstruction François Drielsma Ruslan Asfandiyarov University of Geneva On Behalf of the EMR Group 38 th MICE Collaboration Meeting February 23, 2014 Electron-Muon

More information

Electron Muon Ranger (EMR) Software Development

Electron Muon Ranger (EMR) Software Development Electron Muon Ranger (EMR) Software Development François Drielsma on behalf of the EMR Group University of Geneva June 25, 2014 François Drielsma on behalf of the EMR Group Electron (University Muon of

More information

ATLAS Tile Calorimeter Readout Electronics Upgrade Program for the High Luminosity LHC

ATLAS Tile Calorimeter Readout Electronics Upgrade Program for the High Luminosity LHC ATLAS Tile Calorimeter Readout Electronics Upgrade Program for the High Luminosity LHC Augusto Santiago Cerqueira On behalf of the ATLAS Tile Calorimeter Group Federal University of Juiz de Fora, Brazil

More information

The data acquisition system of the XMASS experiment

The data acquisition system of the XMASS experiment The data acquisition system of the XMASS experiment Katsuki Hiraide 1,2, for the XMASS Collaboration 1 Kamioka Observatory, Institute for Cosmic Ray Research, the University of Tokyo, Higashi-Mozumi, Kamioka,

More information

ISTITUTO NAZIONALE DI FISICA NUCLEARE

ISTITUTO NAZIONALE DI FISICA NUCLEARE ISTITUTO NAZIONALE DI FISICA NUCLEARE Sezione di Catania INFN/TC-11/02 February 28, 2011 PRELIMINARY TESTS OF A SCINTILLATOR-BASED MINI-STATION FOR EXTENSIVE AIR SHOWERS MEASUREMENTS S.Aiola 1, P. La Rocca

More information

Silicon Lab Bonn. Physikalisches Institut Universität Bonn. DEPFET Test System Test Beam @ DESY

Silicon Lab Bonn. Physikalisches Institut Universität Bonn. DEPFET Test System Test Beam @ DESY Silicon Lab Bonn Physikalisches Institut Universität Bonn DEPFET Test System Test Beam @ DESY H. Krüger, EUDET Brainstorming, 3/4.11.2005 1 SI LAB DEPFET Prototype System DEPFET sensors 64 x 128 pixels,

More information

Lucia Masetti Johannes Gutenberg University Mainz PRISMA Cluster of Excellence

Lucia Masetti Johannes Gutenberg University Mainz PRISMA Cluster of Excellence Task 14.2.2 TEST BENCHES FOR THE CHARACTERISATION OF HIGHLY GRANULAR CALORIMETER ELEMENTS WITH SCINTILLATOR AND SIPM READOUT Lucia Masetti Johannes Gutenberg University Mainz PRISMA Cluster of Excellence

More information

MICE Major Milestone Status Revision date: 4/4/12 (MICO 181)

MICE Major Milestone Status Revision date: 4/4/12 (MICO 181) MICE Major Milestone Status Revision date: 4/4/12 (MICO 181) Milestone complete >30 days away

More information

Development. Igor Sheviakov Manfred Zimmer Peter Göttlicher Qingqing Xia. AGIPD Meeting 01-02 April, 2014

Development. Igor Sheviakov Manfred Zimmer Peter Göttlicher Qingqing Xia. AGIPD Meeting 01-02 April, 2014 Textmasterformat AGIPD Firmware/Software bearbeiten Igor Sheviakov Manfred Zimmer Peter Göttlicher Qingqing Xia AGIPD Meeting 01-02 April, 2014 Outline Textmasterformat bearbeiten Reminder: hardware set-up

More information

The Muon Veto DAQ. Florian Ritter. Kepler Center for Astro and Particle Physics. Eberhard Karls Universität Tübingen

The Muon Veto DAQ. Florian Ritter. Kepler Center for Astro and Particle Physics. Eberhard Karls Universität Tübingen The Muon Veto DAQ Florian Ritter Kepler Center for Astro and Particle Physics Eberhard Karls Universität Tübingen Outline Muon Veto Facts I Summary and Outlook Muon Veto Facts plastic scintillator photomultiplier

More information

ORTEC AN34 Experiment 1

ORTEC AN34 Experiment 1 Equipment needed from ORTEC: 480 Pulser 113 Scintillation Preamplifier 4001A/4002D NIM Bin and Power Supply 575A Spectroscopy Amplifier 996 Timer & Counter 551 Timing Single-Channel Analyzer C-29 BNC Tee

More information

PoS(PhotoDet 2012)068

PoS(PhotoDet 2012)068 Characterization of the Hamamatsu R11265 multi-anode photomultiplier tube with single photon signals Luca CADAMURO, Marta CALVI, Andrea GIACHERO,, Matteo MAINO, Clara MATTEUZZI, Gianluigi PESSINA Dipartimento

More information

Pulsar Status Report

Pulsar Status Report Pulsar Status Report PULSAR: PULSer And Recorder Pulsar design overview: from L2 teststand tool to a general purpose tool Current status: schematics/layout, firmware, board level simulation etc. Possible

More information

Aerogel and Assembly. Aerogel shipped to US (IIT) in June; shipment to RAL after inspection. Counter 1: n=1.08; counter 2: n=1.12.

Aerogel and Assembly. Aerogel shipped to US (IIT) in June; shipment to RAL after inspection. Counter 1: n=1.08; counter 2: n=1.12. CKOV Work Packages: Engineering - UCL PMTs - Trieste PMT bases - FNAL PMT Enclosure - IIT Fe Light Box - U Iowa Aerogel - IIT Aerogel compartments - UM Mirrors - UM/FNAL DAQ/Shaper - Geneva/Sofia LED/Pulser

More information

Status and Prospects of HARP. Malcolm Ellis On behalf of the HARP Collaboration NuFact02 Imperial College, July 2002

Status and Prospects of HARP. Malcolm Ellis On behalf of the HARP Collaboration NuFact02 Imperial College, July 2002 Status and Prospects of HARP Malcolm Ellis On behalf of the HARP Collaboration NuFact02 Imperial College, July 2002 The HARP Collaboration: Università degli Studi e Sezione INFN, Bari, Italy Rutherford

More information

Tracking systems in HEP:

Tracking systems in HEP: Tracking systems in HEP: concept and performance of 3 experiments Davide Bolognini Universita' degli Studi dell'insubria Presentazione dottorato Anno I Outline Tracking systems in HEP CMS @ LHC...but not

More information

CHAPTER 11: Flip Flops

CHAPTER 11: Flip Flops CHAPTER 11: Flip Flops In this chapter, you will be building the part of the circuit that controls the command sequencing. The required circuit must operate the counter and the memory chip. When the teach

More information

CMS Tracker module / hybrid tests and DAQ development for the HL-LHC

CMS Tracker module / hybrid tests and DAQ development for the HL-LHC CMS Tracker module / hybrid tests and DAQ development for the HL-LHC S. Mersi, G. Auzinger georg.auzinger@cern.ch 1 Outline Reminder: the Ph2 CMS Tracker upgrade pt Modules: principle, elements, electronics

More information

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector Silicon Seminar Optolinks and Off Detector Electronics in ATLAS Pixel Detector Overview Requirements The architecture of the optical links for the ATLAS pixel detector ROD BOC Optoboard Requirements of

More information

DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING

DEPARTMENT OF ELECTRICAL AND COMPUTER ENGINEERING ECE 1250 Lab 6 Generate Voltages using a Function Generator and Measure Voltages using an Oscilloscope Building: Digital Circuit Build an Electronic Candle Overview: In Lab 6 you will: Build an electronic

More information

An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout

An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout M. Anelli, W. Baldini, P. Ciambrone, M. Dallavalle, F. Fabbri, G. Lanfranchi, A. Montanari INFN-LNF, INFN-Ferrara,

More information

The Timing Counter of the MEG experiment: calibration and performances

The Timing Counter of the MEG experiment: calibration and performances The Timing Counter of the MEG experiment: calibration and performances INFN Pavia On behalf of MEG TC group 12th seminar on IPRD Siena 1 MEG: signal and background background signal µ e γ physical e +

More information

Status of NectarCAM camera project. J-F. Glicenstein (IRFU) for the NectarCAM consortium

Status of NectarCAM camera project. J-F. Glicenstein (IRFU) for the NectarCAM consortium Status of NectarCAM camera project J-F. Glicenstein (IRFU) for the NectarCAM consortium Outline NectarCAM Design and prototyping Focal plane instrumentation Readout and digitization Trigger Acquisition

More information

UTK-4: A simple SiPM board design and test with FemtoDAQ

UTK-4: A simple SiPM board design and test with FemtoDAQ UTK-4: A simple SiPM board design and test with FemtoDAQ Wojtek Skulski SkuTek Instrumentation, 150 Lucius Gordon Drive, West Henrietta, NY 14586 9687 http://www.femtodaq.com Abstract: A simple board with

More information

The new frontier of the DATA acquisition using 1 and 10 Gb/s Ethernet links. Filippo Costa on behalf of the ALICE DAQ group

The new frontier of the DATA acquisition using 1 and 10 Gb/s Ethernet links. Filippo Costa on behalf of the ALICE DAQ group The new frontier of the DATA acquisition using 1 and 10 Gb/s Ethernet links Filippo Costa on behalf of the ALICE DAQ group DATE software 2 DATE (ALICE Data Acquisition and Test Environment) ALICE is a

More information

Trigger & DAQ. Ryan Rivera 8/03/2015. Mu2e

Trigger & DAQ. Ryan Rivera 8/03/2015. Mu2e Trigger & DAQ Ryan Rivera 8/03/2015 TDAQ Scope Includes Optical links between detector and DAQ (bi-directional, control and data) DAQ Servers (detector interface, event building, online processing) Timing

More information

Current Status. UK funding approved for the next 3 years. Calibration package

Current Status. UK funding approved for the next 3 years. Calibration package Neil McCauley Current Status UK funding approved for the next 3 years. Calibration package LED driver and testing Fibre coupling and housing Monitoring system Pseudo-muon source PDRA, Engineering support

More information

Bluetooth HC-06 with serial port module Easy guide

Bluetooth HC-06 with serial port module Easy guide 1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550

More information

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len.

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len. MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3

More information

Technical Information Manual

Technical Information Manual Technical Information Manual Revision n. 3 26 September 2003 MOD. V538 A series 8 CHANNEL NIM-ECL / ECL-NIM TRANSLATORS AND FAN OUT CAEN will repair or replace any product within the guarantee period if

More information

Trigno/Vicon System Integration

Trigno/Vicon System Integration Delsys and Vicon Analog Integration Motion capture systems will often have the ability to sample analog data channels as a convenient means for synchronizing external data streams with motion capture data.

More information

AGIPD Interface Electronic Prototyping

AGIPD Interface Electronic Prototyping AGIPD Interface Electronic Prototyping P.Goettlicher I. Sheviakov M. Zimmer - Hardware Setup, Measurements - ADC (AD9252 14bit x 8ch x 50msps ) readout - Custom 10G Ethernet performance - Conclusions Test

More information

Imaging for Security Inspection Ed Morton

Imaging for Security Inspection Ed Morton Imaging for Security Inspection Ed Morton Overview 2 Low Energy Detectors Checkpoint X-Ray Occupied Vehicle High Speed Computed Tomography High Energy Detectors Standard Speed High Speed Reverse Geometry

More information

Mechanical Design, Fabrication, and Installation

Mechanical Design, Fabrication, and Installation Mechanical Design, W.J. Llope Rice University System MRPCs Tray Design Electronics Installation STAR TOF excellent complicated new & complicated simple STAR MTD excellent simple commodity complicated Outline:

More information

A Multigigahertz Analog Memory with Fast Read-out for the H.E.S.S.-II Front-End Electronics

A Multigigahertz Analog Memory with Fast Read-out for the H.E.S.S.-II Front-End Electronics A Multigigahertz Analog Memory with Fast Read-out for the H.E.S.S.-II Front-End Electronics Eric Delagnes, Fabrice Feinstein, Philippe Goret, Patrick Nayman, Jean-Paul Tavernet, François Toussenel, and

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

Proton tracking for medical imaging and dosimetry

Proton tracking for medical imaging and dosimetry Proton tracking for medical imaging and dosimetry J.Taylor, P.Allport, G.Casse For the PRaVDA Consortium 1 Background and motivation - What is the PRaVDA experiment? - Why are we using Monte Carlo? GEANT4

More information

Week 13: Chap. 18b Multidimensional DAQ

Week 13: Chap. 18b Multidimensional DAQ Week 13: Chap. 18b Multidimensional DAQ Analysis, A to D Multidimensional DAQ -- Trigger logic -- A1900 minimum PID -- Data stream -- Electronics standards -- Real-time computing -- Architectures High

More information

CAPTAN: A Hardware Architecture for Integrated Data Acquisition, Control, and Analysis for Detector Development

CAPTAN: A Hardware Architecture for Integrated Data Acquisition, Control, and Analysis for Detector Development FERMILAB-PUB-08-527-CD CAPTAN: A Hardware Architecture for Integrated Data Acquisition, Control, and Analysis for Detector Development Marcos Turqueti, Ryan A. Rivera, Alan Prosser, Jeffry Andresen and

More information

Galvanic isolated 16 channel transient recorder

Galvanic isolated 16 channel transient recorder Galvanic isolated 16 channel transient recorder Features 16 channels Simultaneous sampling 100 khz bandwidth Max. 200 ks/s per channel Direct readout and/or transient recorder function Input range +/-

More information

Troubleshooting Guide

Troubleshooting Guide PYRAMIX 8 Troubleshooting Guide Merging Technologies Le Verney 4, CH-1070 Puidoux Switzerland www.merging.com/horus T : +41 21 946 04 44 F : +41 21 946 04 45 HORUS Make sure that you are running the latest

More information

Instructions for Setting the T560 Digital Delay Generator for the Target Delay

Instructions for Setting the T560 Digital Delay Generator for the Target Delay Instructions for Setting the T560 Digital Delay Generator for the Target Delay Important! These instructions are only to be followed by beam-line operators who have been trained to operate the target!!

More information

Data Concentrator Modules ATLB. ZYNQ Board EMC DC. VME Gigabit ETH xtca. Advanced Trigger Logic Board. Stand Alone. PANDA EMC Data Concentrator

Data Concentrator Modules ATLB. ZYNQ Board EMC DC. VME Gigabit ETH xtca. Advanced Trigger Logic Board. Stand Alone. PANDA EMC Data Concentrator Data Concentrator Modules ATLB Advanced Trigger Logic Board ZYNQ Board Stand Alone EMC DC PANDA EMC Data Concentrator VME Gigabit ETH xtca Data Concentrator Modules ATLB Advanced Trigger Logic Board ATLB

More information

Development of the electromagnetic calorimeter waveform digitizers for the Fermilab Muon g-2 experiment

Development of the electromagnetic calorimeter waveform digitizers for the Fermilab Muon g-2 experiment Development of the electromagnetic calorimeter waveform digitizers for the Fermilab g-2 experiment 1 on behalf of the Fermilab E989 g-2 Collaboration European Physical Society Conference on High Energy

More information

Beam Loss Monitor Software Guide

Beam Loss Monitor Software Guide Version 1.0 Beam Loss Monitor Software Guide James Leaver 5th December 2008 1 Operating Procedure In order to run the Beam Loss Monitor software, the user should complete the following steps: 1. Open a

More information

A Prototype for TDC-based Readout Electronics for the LP TPC

A Prototype for TDC-based Readout Electronics for the LP TPC EUDET A Prototype for TDC-based Readout Electronics for the LP TPC A. Kaukher, O. Schäfer, H. Schröder, R. Wurth Institut für Physik, Universität Rostock, Germany May 1, 2008 Abstract The Readout Prototype

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) Calorimeter AFEE Board Parts Radiation Test Plan

Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) Calorimeter AFEE Board Parts Radiation Test Plan GLAST LAT DESIGN DESCRIPTION Document Title AFEE Board Parts Radiation Test Plan Document # Date Effective LAT-SS-01890-01 1 April 2003 Prepared by(s) Supersedes James Ampe None Subsystem/Office Calorimeter

More information

DOCUMENTATION FOR ELECTICAL SAFETY REVIEW OF MINOS DETECTOR SYSTEM AT THE MINOS NEAR DETECTOR HALL

DOCUMENTATION FOR ELECTICAL SAFETY REVIEW OF MINOS DETECTOR SYSTEM AT THE MINOS NEAR DETECTOR HALL DOCUMENTATION FOR ELECTICAL SAFETY REVIEW OF MINOS DETECTOR SYSTEM AT THE MINOS NEAR DETECTOR HALL Date Prepared: April 13, 2004 Contact: Peter Shanahan shanahan@fnal.gov X8378 LDP: 630-218-3907 Location:

More information

TEC+ Status Report. Richard Brauer, Lutz Feld, Waclaw Karpinski, Katja Klein, Michael Wlochal. 1.Physikalisches Institut B, RWTH Aachen

TEC+ Status Report. Richard Brauer, Lutz Feld, Waclaw Karpinski, Katja Klein, Michael Wlochal. 1.Physikalisches Institut B, RWTH Aachen TEC+ Status Report Richard Brauer, Lutz Feld, Waclaw Karpinski, Katja Klein, Michael Wlochal 1.Physikalisches Institut B, RWTH Aachen TEC Meeting December 7th, 2005 TEC integration: overview & procedure

More information

The accurate calibration of all detectors is crucial for the subsequent data

The accurate calibration of all detectors is crucial for the subsequent data Chapter 4 Calibration The accurate calibration of all detectors is crucial for the subsequent data analysis. The stability of the gain and offset for energy and time calibration of all detectors involved

More information

X-Band Silicon RADAR Quad Core IC Developer Kit

X-Band Silicon RADAR Quad Core IC Developer Kit mmw Solutions. Enabling a new world Data Sheet Contents 1 x Test board with 14 x RF connectors, 1 x DC connector, and 1 x SPI connector 1 x DC power cable assembly 1 x High speed SPI cable assembly 1 x

More information

Calorimetry in particle physics experiments

Calorimetry in particle physics experiments Calorimetry in particle physics experiments Unit n. 8 Calibration techniques Roberta Arcidiacono Lecture overview Introduction Hardware Calibration Test Beam Calibration In-situ Calibration (EM calorimeters)

More information

THE CMS PIXEL DETECTOR: FROM PRODUCTION TO COMMISSIONING

THE CMS PIXEL DETECTOR: FROM PRODUCTION TO COMMISSIONING THE CMS PIXEL DETECTOR: FROM PRODUCTION TO COMMISSIONING VINCENZO CHIOCHIA On behalf of the CMS Collaboration University of Zürich, Physik-Institut, Winterthurerstr. 190 Zürich, CH-8057, Switzerland The

More information

Istituto Nazionale di Fisica Nucleare Sez di Ferrara. -------------------- PAX PS Board User Manual ---------------

Istituto Nazionale di Fisica Nucleare Sez di Ferrara. -------------------- PAX PS Board User Manual --------------- Istituto Nazionale di Fisica Nucleare Sez di Ferrara. -------------------- PAX PS Board User Manual --------------- Author: Roberto Malaguti Project by:. Angelo Cotta Ramusino, Roberto Malaguti Via Saragat

More information

GIF Irradiation Test with an 8-Plane TRT Endcap Sector Prototype

GIF Irradiation Test with an 8-Plane TRT Endcap Sector Prototype GIF Irradiation Test with an 8-Plane TRT Endcap Sector Prototype Anatoli Romaniouk, Juan Valls CERN Abstract In this document we report the results from a a study of the performance under high rates of

More information

OPTICAL FIBERS INTRODUCTION

OPTICAL FIBERS INTRODUCTION OPTICAL FIBERS References: J. Hecht: Understanding Fiber Optics, Ch. 1-3, Prentice Hall N.J. 1999 D. R. Goff: Fiber Optic Reference Guide (2 nd ed.) Focal Press 1999 Projects in Fiber Optics (Applications

More information

OVERVIEW Playbacks: Shortcuts: Memories: Data Entry Wheels: Touchpad: Master and Blackout:

OVERVIEW Playbacks: Shortcuts: Memories: Data Entry Wheels: Touchpad: Master and Blackout: OVERVIEW The MIDIcon is a USB MIDI control panel designed to work alongside the Elation lighting software packages. The Midicon is USB powered and uses the USB class drivers so that no driver needs to

More information

Lab 3: Introduction to Data Acquisition Cards

Lab 3: Introduction to Data Acquisition Cards Lab 3: Introduction to Data Acquisition Cards INTRODUCTION: In this lab, you will be building a VI to display the input measured on a channel. However, within your own VI you will use LabVIEW supplied

More information

T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades

T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades R. Milinčić1, P. Gorham1, C. Hebert1, S. Matsuno1, P. Miočinović1, M. Rosen1, D. Saltzberg2, G. Varner1 1 University

More information

THE TESLA TEST FACILITY AS A PROTOTYPE FOR THE GLOBAL ACCELERATOR NETWORK

THE TESLA TEST FACILITY AS A PROTOTYPE FOR THE GLOBAL ACCELERATOR NETWORK THE TESLA TEST FACILITY AS A PROTOTYPE FOR THE GLOBAL ACCELERATOR NETWORK K. Rehlich, DESY, Hamburg, Germany Abstract The next generation of large accelerators facilities will be produced and operated

More information

T3 Series. General Purpose IO for Integrators

T3 Series. General Purpose IO for Integrators General Purpose IO for Integrators -1- TABLE OF CONTENTS Table of Contents Technical Data 3 Standard Operation 4 Inputs 4 Outputs 4 Analog Output Calibration 4 Bandrate 4 Master Timer Clock Function for

More information

VME Data Acquisition System: Fundamentals and Beyond. Abhinav Kumar Bhabha Atomic Research Centre, Mumbai March 2011

VME Data Acquisition System: Fundamentals and Beyond. Abhinav Kumar Bhabha Atomic Research Centre, Mumbai March 2011 VME Data Acquisition System: Fundamentals and Beyond Abhinav Kumar Bhabha Atomic Research Centre, Mumbai March 2011 Presentation Outline Chapter 1 -------------------------------- Introduction to VME Chapter

More information

Crate electronics. status and future plannings TRD. IEKP - Universität Karlsruhe (TH) Levin Jungermann, Mike Schmanau, Valery Zhukov

Crate electronics. status and future plannings TRD. IEKP - Universität Karlsruhe (TH) Levin Jungermann, Mike Schmanau, Valery Zhukov TRD Crate electronics status and future plannings Wim de Boer, Martin Brückel, Florian Hauler, Levin Jungermann, Mike Schmanau, Valery Zhukov IEKP - Universität Karlsruhe (TH) U-crate electronics overview

More information

Timing calibration in NEMO. M. Circella Istituto Nazionale di Fisica Nucleare, Bari on behalf of the NEMO Collaboration

Timing calibration in NEMO. M. Circella Istituto Nazionale di Fisica Nucleare, Bari on behalf of the NEMO Collaboration Timing calibration in NEMO M. Circella Istituto Nazionale di Fisica Nucleare, Bari on behalf of the NEMO Collaboration NEMO Telescope layout 200 m Tower 200 m 1 primary Junction Box 8 secondary Junction

More information

Image Processing Techniques applied to Liquid Argon Time Projection Chamber(LArTPC) Data

Image Processing Techniques applied to Liquid Argon Time Projection Chamber(LArTPC) Data Image Processing Techniques applied to Liquid Argon Time Projection Chamber(LArTPC) Data Jessica Esquivel On Behalf of the MicroBooNE Collaboration Syracuse University Advisor: Mitch Soderberg Outline

More information

NIM High Voltage Power Supplies

NIM High Voltage Power Supplies NIM High Voltage Power Supplies NIM High Voltage Power Supplies are the best choice for small experiments in which a really low noise feature is expected. offer a new generation of NIM Power Supplies that

More information

TI 313 (1.0 EN) d&b Remote network - Integration

TI 313 (1.0 EN) d&b Remote network - Integration TI 313 (1.0 EN) d&b Remote network - Integration 1. Introduction The d&b Remote network offers various options to configure, control and monitor a d&b sound reinforcement system. This can be done by either

More information

Hall B 12GeV RICH Detector. Electronics. ASIC circuit board layout notes Version 2_4_a

Hall B 12GeV RICH Detector. Electronics. ASIC circuit board layout notes Version 2_4_a Hall B 12GeV RICH Detector Electronics ASIC circuit board layout notes Version 2_4_a C. Cuevas 2016 Sept 13 Cuevas -- 2016Sept 1 Version 2.4 Input signal traces occupy several layers Good Length of input

More information

PLAS: Analog memory ASIC Conceptual design & development status

PLAS: Analog memory ASIC Conceptual design & development status PLAS: Analog memory ASIC Conceptual design & development status Ramón J. Aliaga Instituto de Física Corpuscular (IFIC) Consejo Superior de Investigaciones Científicas (CSIC) Universidad de Valencia Vicente

More information

APPLICATION NOTE GaGe CompuScope 14200-based Lightning Monitoring System

APPLICATION NOTE GaGe CompuScope 14200-based Lightning Monitoring System APPLICATION NOTE GaGe CompuScope 14200-based Lightning Monitoring System Challenge A customer needed to upgrade an older data acquisition unit for a real-time lightning monitoring system. Unlike many lightning

More information

Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam.

Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam. 5 th International Workshop on Radiation Safety at Synchrotron Radiation Sources Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam. A. Vascotto 1, K. Casarin 1, S.

More information

ISTITUTO NAZIONALE DI FISICA NUCLEARE

ISTITUTO NAZIONALE DI FISICA NUCLEARE ISTITUTO NAZIONALE DI FISICA NUCLEARE Sezione di Genova INFN-14-21/GE 18 th December 2014 CLB TEST REPORT Antonio Orzelli 1, Vladimir Kulikovskiy 1, Paolo Musico 1, Massimiliano Cresta 1, Christophe Hugon

More information

www.caen.it UNI EN ISO 9001 CERT. N. 9105.CAEN November 2006 EURITRACK Workshop

www.caen.it UNI EN ISO 9001 CERT. N. 9105.CAEN November 2006 EURITRACK Workshop www.caen.it UNI EN ISO 9001 CERT. N. 9105.CAEN November 2006 EURITRACK Workshop CAEN SpA Costruzioni Apparecchiature Elettroniche Nucleari Spin-offs of the Italian Nuclear Physics Research Institute, CAEN

More information

FPIX Maintenance Plan

FPIX Maintenance Plan Pixel General Meeting FPIX Maintenance Plan 13/05/2013 Mauro Dinardo Universita` degli Studi di Milano Bicocca - INFN, Italy List repair: BpO Disk 1: 1 panel change FPix_BpO_D1_BLD5_PNL2 Disk 2: no panel

More information

MST MIDI to CV Module

MST MIDI to CV Module MST MIDI to CV Module For help with technical terms in this manual, check out these links: Glossary of MIDI terms: http://www.midi.org/aboutmidi/glossary.php Intro to MIDI: https://www.soundonsound.com/sos/1995_articles/aug95/midibasics1.html

More information

Interfacing Credit Card-sized PCs to Board Level Electronics

Interfacing Credit Card-sized PCs to Board Level Electronics 10th ICALEPCS Int. Conf. on Accelerator & Large Expt. Physics Control Systems. Geneva, 10-14 Oct 2005, PO2.062-4 (2005) Interfacing Credit Card-sized PCs to Board Level Electronics Flavio Fontanelli 1,

More information

Technote: Characterization of the LED Flasher Calibration System for the µboone PMT Array

Technote: Characterization of the LED Flasher Calibration System for the µboone PMT Array Technote: Characterization of the LED Flasher Calibration System for the µboone PMT Array Zander Moss August, 2014 1 Introduction Operating an optical system with high timing and charge resolution requires

More information

WBS 1.8 Trigger Electronics & Software. Production, Production Testing and Quality Assurance Plan

WBS 1.8 Trigger Electronics & Software. Production, Production Testing and Quality Assurance Plan WBS 1.8 Trigger Electronics & Software Production, Production Testing and Quality Assurance Plan BTeV Document 1046 Edited by Erik Gottschalk, Vince Pavlicek, Michael Haney 1 INTRODUCTION... 3 2 LEVEL

More information

RICH. INFN Perugia INFN Firenze CERN. M.Lenti

RICH. INFN Perugia INFN Firenze CERN. M.Lenti RICH INFN Perugia INFN Firenze CERN M.Lenti Separate pions from muons

More information

Below is a diagram explaining the data packet and the timing related to the mouse clock while receiving a byte from the PS-2 mouse:

Below is a diagram explaining the data packet and the timing related to the mouse clock while receiving a byte from the PS-2 mouse: PS-2 Mouse: The Protocol: For out mini project we designed a serial port transmitter receiver, which uses the Baud rate protocol. The PS-2 port is similar to the serial port (performs the function of transmitting

More information

DIGITAL SPECTROSCOPY. Our cutting edge technology for everyday need of laboratory analysis, security and environmental monitoring

DIGITAL SPECTROSCOPY. Our cutting edge technology for everyday need of laboratory analysis, security and environmental monitoring DIGITAL SPECTROSCOPY Our cutting edge technology for everyday need of laboratory analysis, security and environmental monitoring In the last decade CAEN developed a wide offer of digital data acquisition

More information

ViZion Installation Guide

ViZion Installation Guide ViZion Installation Guide v2.0 1 ViZion Installation Guide Table of Contents Inventory Hardware Setup Understanding Synchronization Cable Begin by taking an inventory of the required equipment DR Unit

More information

Neutron Detection Setups proposed for

Neutron Detection Setups proposed for Neutron Detection Setups proposed for DESPEC D. Cano-Ott on behalf of the WG members CIEMAT, IFIC, LNL, FYL, UPC, UU, UW Motivation GOAL: to measure neutron emission probabilities and energies for neutron

More information

THE DØ Luminosity Monitor (LM) consists of two array of

THE DØ Luminosity Monitor (LM) consists of two array of FERMILAB-CONF-6-469-E Radiation Damage to Scintillator in the DØ Luminosity Monitor Brendan Casey, Kayle DeVaughan, Yuji Enari, Richard Partridge, and Sahal Yacoob Abstract We report the result of evaluating

More information

Supervisors: Mr.K.Rotter/ Mr.S.Mondal Author: Mr.P.Adams

Supervisors: Mr.K.Rotter/ Mr.S.Mondal Author: Mr.P.Adams PLC Application Exercise 7 Four Floor Elevator 1. Aim You will develop your problem solving skills by programming a real life engineering problem. This application exercise will bring together what you

More information

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components

More information

Febex Data Acquisition System

Febex Data Acquisition System Febex Data Acquisition System (FPGA Hit Finder and Energy Filter for the FEBEX Pipelining ADC) Dr. Ivan Rusanov for CSEE, GSI - Darmstadt CSEE meeting, GSI 24.02.2014., Darmstadt The Febex Data AcquisitionSystem

More information

Construction of a Digital Hadron Calorimeter

Construction of a Digital Hadron Calorimeter Construction of a Digital Hadron Calorimeter José Repond 1 For the DHCAL Collaboration 1 Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL, U.S.A. The DHCAL collaboration is assembling a large

More information

Digital to Analog Conversion Using Pulse Width Modulation

Digital to Analog Conversion Using Pulse Width Modulation Digital to Analog Conversion Using Pulse Width Modulation Samer El-Haj-Mahmoud Electronics Engineering Technology Program Texas A&M University Instructor s Portion Summary The purpose of this lab is to

More information

RCC2 Test Proceedures

RCC2 Test Proceedures RCC2 Test Proceedures 1. Power-up Test 1. install board in VME crate (6U style or 6U section of 9U) and turn on power 2. check that cfg LED (D4) on front panel and D3 LED on board near U47 are lit (red)

More information

MIDI SWITCHING PRODUCTS

MIDI SWITCHING PRODUCTS P E A K MIDI SWITCHING PRODUCTS FCB4N2 PROGRAMMABLE MIDI FOOT CONTROLLER OWNER S MANUAL Document Rev.2.1.0 Feb.11.2010 www.peak2005.com Table of contents INTRODUCTION.......3 Overview.......3 TOP Panel..3

More information