1 NIM High Voltage Power Supplies NIM High Voltage Power Supplies are the best choice for small experiments in which a really low noise feature is expected. offer a new generation of NIM Power Supplies that can operate in daisy-chain network and can be locally or remotely controlled through a dedicated software. In this way it s possible to control up to 128 channels and make of this set-up a complete system. The NIM Line includes also the NDT power supplies, which are hosted in a NIM module and can be plugged in NIM crates for power but have also the chance of Desktop operation thanks to a mains power supply cord. INDEX Power Supplies Modular Pulse Processing Electronics Spectroscopy Solutions Universal Multichannel System VME High Voltage Power Supplies NIM High Voltage Power Supplies Desktop High Voltage Power Supplies High Power Low Voltage System Power Supply Control Software NIM High Voltage Power Supplies NDT High Voltage Power Supply Family Educational Kit Liquid Argon TPC Readout System Readout System for Multiplexed Signals Digital Detector Emulator Accessories NIM High Voltage Power Supplies NDT High Voltage Power Supply Family
2 46 Power Supplies / NIM High Voltage Power Supplies 2014 Product Catalog q NIM High Voltage Power Supplies N1419 4/2/1 Channel 500 V/200 μa NIM HV Power Supply Family The N1419 provides 4 independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1419A and N1419B) are also available. Each channel can provide a ±500 V / 200 μa max output. The output polarity is independently selectable for each channel. Channels have common floating return (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. for each channel in the range 1 50 V/s in 1 V/s steps. The module features 10 na Iset/Imon resolution. A Zoom option (x 10) is available for Imon, increasing resolution to 1nA. Power supply control can be performed either locally, assisted by a graphic color display or remotely, via USB, RS232 or RS485, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via TCP/IP by the Smart Fan Unit of NIM8301. A complete set of software tools is available to control these units, from low level libraries to graphical application software. For detailed information see the Power Supply Control Software section. from the programmed value by more than 2% of set value (minimum 1 V). OVERCURRENT detection: if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function. Special versions available: 2U NIM module with Vac plug, USB/Ethernet and touch screen display for desktop operation (NDT1419). See relative section for NIM/desktop modules. x 10 Imon Zoom, increasing Imon resolution to 1 na. Common Features STANDARD N A - N1419B 4/2/1 channels in 1U NIM module Under/over-voltage alert, overcurrent and max. voltage protection Graphic colour display Local and Remote control Interlock logic for board enable and Individual channel kill 2U/Desktop (with Vac) version available N1419 channel features ±500 V/200 μa output ranges Max Ripple smaller than 5mVpp 50 mv Vset/Vmon resolution 10nA Iset/Imon resolution (optional Imon-Zoom: 1 na) Programmable ramp-up / rampdown ((1-50 V/s) N V Programmable Power Supply Family General Selection Table N. of ch. Form Factor Interfaces Model NIM NIM/DT LOCAL REMOTE N1419 X X X X N1419A X X X X N1419B X X X X NDT1419 X X X X WN1419XAAAAA WN1419AXAAAA WN1419BXAAAA WPERS WPERS N Ch NIM Progammable HV Power Supply (±500V, 200μA, 10nA res.) N1419A - 2 Ch NIM Progammable HV Power Supply (±500V, 200μA, 10nA res.) N1419B - 1 Ch NIM Progammable HV Power Supply (±500V, 200μA, 10nA res.) N14XX Customization Imon Zoom N14XX Customization - Internal Common Ground
3 2014 Product Catalog Power Supplies / NIM High Voltage Power Supplies 47 NIM High Voltage Power Supplies - continued q N1470 4/2/1 Channel 8 kv/3 ma (8 W) NIM HV Power Supply Family The N1470 provides 4 independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1470A and N1470B) are also available. Each channel can provide a ±8 kv max voltage, a 3 ma max current and a 9 W max power (8 W max power when output voltage is larger than ±3 kv). The output polarity is independently selectable for each channel. Channels have common floating return (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. for each channel in the range V/s in 1 V/s steps. The module features 50 na Iset/Imon resolution. A Zoom option (x 10) is available for Imon, increasing resolution to 5 na. Power supply control can be performed either locally, assisted by a graphic color display or remotely, via USB, RS232 or RS485, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via TCP/IP by the Smart Fan Unit of NIM8301. A complete set of software tools is available to control these units, from low level libraries to graphical application software. For detailed information see the Power Supply Control Software section. from the programmed value by more than 2% of set value (minimum 10 V). OVERCURRENT detection: if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function. Special versions available: 2U NIM module with Vac plug, USB/Ethernet and touch screen display for desktop operation (NDT1470). See relative section for NIM/desktop modules. 2 channels Low Cost version only locally controllable (N1470AL) 2 channels Low Cost version only remotely controllable (N1470AR) x 10 Imon Zoom, increasing Imon resolution to 5 na. Common Features 4/2/1 channels in 1U NIM module Under/over-voltage alert, overcurrent and max. voltage protection Graphic colour display Local and Remote control Interlock logic for board enable and Individual channel kill 2U/Desktop (with Vac) version available Low cost and 2U/Desktop versions available STANDARD N N1470A - N1470B Low Cost LOCAL N1470AL Low Cost REMOTE N1470AR N kv NIM Programmable Power Supply Family N. of ch. Form Factor Interfaces Model NIM NIM/DT LOCAL REMOTE N1470 X X X X N1470A X X X X N1470B X X X X NDT1470 X X X X N1470AL LC X X X N1470AR LC X X X N1470 channel features ±8 kv/3ma output ranges 200 mv Vset/Vmon resolution 50 na Iset/Imon resolution (optional Imon-Zoom: 5 na) Programmable ramp-up / rampdown (1-500 V/s) WN1470X08AAC WN1470A08AAC WN1470B08AAC WN1470ALCLAA WN1470ALCRAA WPERS WPERS N Ch NIM Programmable HV Power Supply (±8kV, 3mA, 50nA res.) N1470A - 2 Ch NIM Programmable HV Power Supply (±8kV, 3mA, 50nA res.) N1470B - 1 Ch NIM Programmable HV Power Supply (±8kV, 3mA, 50nA res.) N1470AL - 2 Ch NIM Low Cost Locally Progammable HV Power Supply (±8kV, 3mA, 50nA res.) N1470AR - 2 Ch NIM Low Cost Remotely Progammable HV Power Supply (±8kV, 3mA, 50nA res.) N14XX Customization Imon Zoom N14XX Customization - Internal Common Ground
4 48 Power Supplies / NIM High Voltage Power Supplies 2014 Product Catalog q NIM High Voltage Power Supplies - continued N1471 4/2/1 Channel 5.5 kv NIM HV Power Supply High Accuracy Family The Mod. N1471 provides 4 independent High Voltage channels in a single width NIM mechanics. Two and one channel versions (N1471A and N1471B) are also available. Each channel can provide a ±5.5 kv / 300 µa output. The output polarity is independently selectable for each channel. Channels have common floating return (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. for each channel in the range V/s in 1 V/s steps. The module features 5 na Iset/Imon resolution. A Zoom option (x 10) is available for Imon, increasing resolution to 500 pa. Power supply control can be performed either locally, assisted by a graphic color display or remotely, via USB, RS232 or RS485, the latter allowing to build a daisy chain network of modules N14XX. It is also controllable via TCP/IP by the Smart Fan Unit of NIM8301. A complete set of software tools is available to control these units, from low level libraries to graphical application software. For detailed information see the Power Supply Control Software section. from the programmed value by more than 2% of set value (minimum 10 V). OVERCURRENT detection: if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function. Special versions available: 2U NIM module with 220V/110V AC plug for desktop operation (NDT1471). See relative section for NIM/desktop modules. High Resolution models (N1471H/N1471HA/N1471HB e NDT1471H) with 20 µa maximum output and higher current monitor resolution: 1 na or 50 pa If Imon Zoom activated (for High Res. Models, Imon-zoom feature is installed by default). x 10 Imon Zoom, increasing Imon resolution to 500 pa (N1471x models only). Common Features STANDARD N N1471A/B - N1471H/HA/HB 4/2/1 channels in 1U NIM module Under/over-voltage alert, overcurrent and max. voltage protection Graphic colour display Local and Remote control Interlock logic for board enable and Individual channel kill 2U/Desktop (with Vac) version available N1471 channel features ±5.5 kv/300 μa output ranges Max Ripple smaller than 10 mvpp 100 mv Vset/Vmon resolution 5 na Iset/Imon resolution (optional Imon-Zoom: 500 pa) Current offset calibration High resolution versions also available (20 μa max output, Iset/ Imon: 1nA, optional Imon-Zoom: 50 pa) Programmable ramp-up / rampdown (1-500 V/s) N kv NIM Programmable Power Supply High Accuracy Family General Selection Table Model N. of ch. Form Factor Interfaces NIM NIM/DT LOCAL REMOTE N1471 X X X X N1471A X X X X N1471B X X X X N1471H X X X X N1471HA X X X X N1471HB X X X X NDT1471 X X X X NDT1471H X X X X WN1471X05AAC N Ch NIM Programmable HV Power Supply (±5.5kV, 300µA, 5nA res.) WN1471A05AAC N1471A - 2 Ch NIM Programmable HV Power Supply (±5.5kV, 300µA, 5nA res.) WN1471B05AAC N1471B - 1 Ch NIM Programmable HV Power Supply (± 5.5kV, 300µA, 5nA res.) WN1471HX05AC N1471H - 4 Ch NIM Programmable High CurrentRes. HV Power Supply (±5.5kV, 20µA, 1nA res.) WN1471HA05AC N1471HA - 2 Ch NIM Programmable High CurrentRes. HV Power Supply (±5.5kV, 20µA, 1nA res.) WN1471HB05AC N1471HB - 1 Ch NIM Programmable High CurrentRes. HV Power Supply (±5.5kV, 20µA, 1nA res.) WPERS N14XX Customization Imon Zoom WPERS N14XX Customization - Internal Common Ground
5 2014 Product Catalog Power Supplies / NIM High Voltage Power Supplies 49 COMING SOON N1570 NIM High Voltage Power Supplies - continued 2 Channel 15 kv/1 ma (10 W) NIM HV Power Supply Module q The N1570 provides 4 independent High Voltage channels in a double width NIM mechanics. Each channel can provide a ±15 kv max voltage, a 1 ma max current and a 10 W max power. The output polarity is independently selectable for each channel. Channels have common floating return (common return insulated from the crate ground); HV outputs are delivered through Lemo HV connectors. for each channel in the range V/s in 1 V/s steps. The module features 20 na Iset/Imon resolution. A Zoom option (x 10) is available for Imon, increasing resolution to 2 na. Module control can take place either locally thanks to a 2.8 Touchscreen Graphic color LCD display with a completely redesigned user interface or remotely, via USB or Ethernet, taking advantage of the new 2020 Control Software. from the programmed value by more than 2% of set value. OVERCURRENT detection: if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function. Available Option: 2 channels in 2U NIM module LEMO HV coaxial output connectors Under/over-voltage alert, overcurrent and max. voltage protection 2.8 color touch screen display Local and Remote control (USB2.0/Ethernet) Interlock logic for board enable and Individual channel kill pag 57.. WN1570XAAAAA N Ch NIM Programmable HV Power Supply ( ±15kV, 1mA, 20nA res.) N472 4 Channel 6 kv Power Supply The N472 is a double width NIM unit housing 4 independent High Voltage channels. The output voltages range from 0 to ±3 kv / 3 ma, or up to ±6 kv / 1 ma (max. output ripple of 30 mvpp at full load). The output polarity is independently selectable for each channel. All channels have individual settings and feature test points and connectors for the monitoring of voltages and currents. The setting of the output voltages can be done locally, via trimmers located on the front panel, or remotely, via analog signals. The setting of the output maximum Voltage and Current limit can be done only locally via front panel trimmers. The channel polarity, overcurrent status and reaching of the VMAX limit are displayed on front panel LEDs. The High Voltage enable can be set both locally, via front panel switch, and remotely, via an external TTL level. Each channel can be individually turned on, either locally or remotely. The module is intrinsically safe: the High Voltage is present only on the SHV output connectors. The module can be powered either by the NIM crate or with 110/220 Vac via a back panel Standard European connector. Two output ranges: ±3 kv / 3 ma and ±6 kv / 1 ma 4 channels in a double width unit Positive or negative polarity selectable for each channel Local or remote individual channel setting and monitoring Remote HV Enable via TTL common to all channels Hardware HV limit 110/220 Vac external power available WN472XAAAAAA N472-4 Channel NIM High Voltage Power Supply (± 6 kv 1 ma, ± 3 kv 3 ma)
6 50 Power Supplies / NIM High Voltage Power Supply / NDT High Voltage Power Supply Family 2014 Product Catalog q NDT High Voltage Power Supply Family NDT14xx 4 Channel NIM/Desktop HV Power Supply Family The NDT14xx is a new Power Supply Family providing 4 independent High Voltage channels in both NIM and Desktop form factor. Desktop operation (110/220 AC Powered) needs no crate and enhance portability. For all the versions the output polarity is independently selectable for each channel and channels have common floating return (common return insulated from the crate ground); HV outputs are delivered through SHV connectors. Module control can take place either locally thanks to a 2.8 Touchscreen Graphic color LCD display with a completely redesigned user interface or remotely, via USB or Ethernet, taking advantage of the new 2020 Control Software. An RS485 communication protocol is also available for daisy chaining up to 32 units. The different versions span from 500 V to 8 kv and from 20 µa to 3 ma, meeting the needs of a wide range of detectors. Current monitoring can be enhanced thanks to the Imon Zoom feature, which increase the resolution of at least a x10 factor. The HV output RAMP-UP and RAMP-DOWN rates may be selected independently for each channel in the range V/s in 1 V/s steps. Highligths 4 channels in 2U NIM module Vac plug for desktop operation Under/over-voltage alert, overcurrent and max. voltage protection 2.8 color touch screen display Local and Remote control (USB2.0/Ethernet) Interlock logic for board enable and Individual channel kill Available models Model V Full Scale Maximum Current Iset/Imon resolution NDT kv 3 ma 50 na (5 na) NDT V 200 μa 5 na (0.5 na) NDT kv 300 μa 5 na (0.5 na) NDT1471H 5.5 kv 20 μa 1 na (50 pa) OVERVOLTAGE and UNDERVOLTAGE warning when the output voltage differs from the programmed value by more than 2% of set value (minimum 10 V). OVERCURRENT detection: if a channel tries to draw a current larger than its programmed limit, it enters TRIP status, keeping the maximum allowed value for a programmable time (TRIP), before being switched off Common Interlock logic for channels enable/disable and individual inputs signal for channel Kill function. Power Supply stand-alone Touch screen for local control Ethernet and USB connection WNDT1419AAAA WNDT1470AAAA WNDT1471AAAA WNDT1471HAAA WPERS NDT Ch NIM/Desktop Progammable HV Power Supply (±500V, 200uA, 5nA res.) NDT Ch NIM/Desktop Progammable HV Power Supply (±8kV, 3mA, 50nA res.) NDT Ch NIM/Desktop Progammable HV Power Supply (±5.5kV, 300uA, 5nA res.) NDT1471H - 4 Ch NIM/Desktop Progammable High CurrentRes. HV Power Supply (±5.5kV, 20uA, 1nA res.) N14XX Customization - Internal Common Ground
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
More informationDielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing
Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The
More informationHigh Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
More information400-800. Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***
INPUT Input protection Thermal protection Switching frequency internal fuse standard 100KHz Input with PFC : (MML400PFC, MML600, MML800) Input voltage range 85*-264VAC Inrush current (peak) MML400PFC
More informationNETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
More informationHigh Voltage Power Supplies
Source voltages up to 5kV and 10kV 1µA current measurement resolution Multi-channel programmable DC power supplies Low noise for precision sourcing and sensitive measurements; selectable filters reduce
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationMPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
More information1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
More informationDC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
More informationAgilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationLow and High Voltage Power Supplies
Low and High Voltage Power Supplies We work according to ISO 9001: 2008 Since 1994 Fug works according to the quality assurance system ISO 9001. All shipped units are checked and documented in our testing
More informationDCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
More informationTechnical Information Manual
Technical Information Manual Revision n. 3 26 September 2003 MOD. V538 A series 8 CHANNEL NIM-ECL / ECL-NIM TRANSLATORS AND FAN OUT CAEN will repair or replace any product within the guarantee period if
More informationFREQUENCY RESPONSE ANALYZERS
FREQUENCY RESPONSE ANALYZERS Dynamic Response Analyzers Servo analyzers When you need to stabilize feedback loops to measure hardware characteristics to measure system response BAFCO, INC. 717 Mearns Road
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationDesigning the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station +82-2-578-6516 І sales@wonatech.
ZIVE Electrochemical Workstations ZIVE SP2 Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station +82-2-578-6516 І sales@wonatech.com www.wonatech.com
More informationDisturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
More informationDPI 260 SERIES: Digital Pressure Indicators
DPI 260 SERIES: Digital Pressure Indicators INTRODUCTION The DPI 260, 261 and 262 range of digital pressure instruments measure and indicate pressure in any specified scale units and provide accuracies
More informationKONSTANTER SPL 250-30 / SPL 400-40 Programmable Electronic Load
3-349-701-03 1/1.13 4 operating modes: constant current, constant voltage, constant load, constant power High speed sequence and transient measurement, short-circuit proof, battery discharging and other
More informationDP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.
DP800 Programmable Linear DC Power Supply DP832A/832:3 Outputs, CH CH2,CH3,Total Power up to 95W DP83A:3 Outputs, CH CH2,CH3,Total Power up to 60W DP8A: Output, 40V/5A or 20V/0A, with Remote Sense, Total
More informationResidual Gas Analyzers
Residual Gas Analyzers RGA100/200/300 100 amu, 200 amu and 300 amu systems SRS Residual Gas Analyzers 100, 200 and 300 amu systems Better than 1 amu resolution 6 decades of dynamic range 5 10 14 Torr detection
More informationPhysical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
More informationMicro800 Programmable Controllers. Bulletin 2080 Selection Guide
Micro800 Programmable Controllers Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationEaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
More informationHVDP. High Voltage Dynamic Power supply/source. 1, 2.5 and 5kW Output DC + Sine Wave Family
Milano, 12 March 2015 HVDP High Voltage Dynamic Power supply/source 1, 2.5 and 5kW Output DC + Sine Wave Family HVDP (High Voltage Dynamic Power) is a family of power supply/source designed to generate
More informationFRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment
FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS drm TesT equipment dt230 playback of drm signals recording of drm signals channel simulation receiver performance analysis real-time modulation Architecture
More informationOPTICAL FIBER repeaters/ isolators
OPTICAL FIBER repeaters/ isolators FUNCTINALITY AND RELIABILITY' Optical Fiber converters give the possibilità to extend on Optical Fiber (also at the same time) every type of network/bus (LAN/Ethernet,
More informationRenewable Energy Monitor User Manual And Software Reference Guide. sales@fuelcellstore.com (979) 703-1925
Renewable Energy Monitor User Manual And Software Reference Guide sales@fuelcellstore.com (979) 703-1925 1 Introducing the Horizon Renewable Energy Monitor The Renewable Energy Monitor is an educational
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationU1602A Handheld Oscilloscopes, 20 MHz
Products & Services Technical Support Buy Industries About Agilent United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1602A Handheld Oscilloscopes, 20 MHz Product
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationChassis, Power Supply, and Element Management
Chassis, Power Supply, and Element Management C-COR CHP Max5000 Converged Headend Platform Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged high-
More informationINPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS
VMC A4 INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS PRODUCT DATA SHEET FEATURES RF to 0-10 VDC out, analogue or PWM Maximal 3 digital inputs to RF RF communication with other equipment Wireless
More informationugrid Testbed. Rein in microgrid complexity. With ease.
ugrid Testbed. Rein in microgrid complexity. With ease. Outsmart the microgrid. ugrid Testbed Ultimate test solution for microgrid control system verification What is a microgrid? Microgrid is a collection
More informationDash 18X / Dash 18 Data Acquisition Recorder
75 Dash 18X / Dash 18 Data Acquisition Recorder QUICK START GUIDE Supports Recorder System Software Version 3.1 1. INTRODUCTION 2. GETTING STARTED 3. HARDWARE OVERVIEW 4. MENUS & BUTTONS 5. USING THE DASH
More informationUser's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationApplications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
More informationIdeal for high dynamic range measurements from compression to noise floor
USB/Ethernet Very Wideband Synthesized Signal Generator 5Ω -75 dbm to +14 dbm, 25 khz - 64 MHz The Big Deal Cost effective production test solution Power level resolution of.1 db Frequency resolution under.1
More informationVoltech DC1000. Precision DC Bias Current Source
DC1000 Precision DC Bias Current Source DC1000 Precision DC Bias Current Source TM Integral Rack Mount Lugs High Contrast Green LED Display Easy Control Rotary Knob Output LED Indicator DC 1000 OUTPUT
More informationDS1104 R&D Controller Board
DS1104 R&D Controller Board Cost-effective system for controller development Highlights Single-board system with real-time hardware and comprehensive I/O Cost-effective PCI hardware for use in PCs Application
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationTechnical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
More informationTI 313 (1.0 EN) d&b Remote network - Integration
TI 313 (1.0 EN) d&b Remote network - Integration 1. Introduction The d&b Remote network offers various options to configure, control and monitor a d&b sound reinforcement system. This can be done by either
More informationin widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.
600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationA compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Bulletin -01E http://www.yokogawa.com/tm/... Visit our website to sign for e-mail updates Compact,
More informationTransmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
More informationDash 8Xe / Dash 8X Data Acquisition Recorder
75 Dash 8Xe / Dash 8X Data Acquisition Recorder QUICK START GUIDE Supports Recorder System Software Version 2.0 1. INTRODUCTION 2. GETTING STARTED 3. HARDWARE OVERVIEW 4. MENUS & BUTTONS 5. USING THE DASH
More informationLT-82 Stationary IR Transmitter
LT-82 Stationary IR Transmitter Configuration LT-82-0 (North America) LT-82-02 (Asia, UK) LT-82-03 (Euro) The Listen LT-82 is the heart of a stationary IR listening system. It takes the desired audio signal
More informationAgilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
More informationUser s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual
User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual Certificate of Product Warranty This product s warranty, provided by our company, covers a period of 1 year form the date of purchase.
More informationSystem Wiring Design Guide
System Wiring Design Guide This guide will help demonstrate the various types of wiring solutions available when connecting video surveillance cameras to EZ Watch Pro and Armor Pro Digital Video Recorders.
More informationCPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output
NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages
More informationSIMADYN D Digital Control System. Interface module SE21.2. User Manual. Edition 05.95 DK-Nr. 282042
SIMADYN D Digital Control System User Manual Interface module SE21.2 Edition 05.95 DK-Nr. 282042 User Manual, Interface module SE21.2 Edition Edition status 1 Interface module SE21.2 04.91 2 Interface
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationthink ahead www.trilithic.com 1-800-TRILITHIC One-box Integrated Solution Flexible & Expandable Open Architecture IP-Based Alerting Protocols
One-box Integrated Solution Flexible & Expandable Open Architecture IP-Based Alerting Protocols Ethernet Support for Remote Network Control CAP IPAWS Trilithic introduces the next generation EAS platform,
More informationTURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More information1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
More informationLEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
More informationSTANDALONE PCI INTERFACE PACKAGE
PACKAGE USER S MANUAL DOC-039 Rev. 1.1 Copyright 2009 All Rights Reserved MED Associates, Inc. P.O. Box 319 St. Albans, Vermont 05478 www.med-associates.com - ii - TABLE OF CONTENTS Chapter 1... 1 Introduction...1
More informationSubstation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
More informationHCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
More informationBITMAIN. APW3-12-1600 PSU Series User Guide
BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...
More informationEDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
More informationSCD Server. SCD Server Pro
SCD Server SCD Server Pro SCD Server & SCD Server Pro 9850-000387-01 - Page 1 of 8 SCD Server and SCD Server Pro The SCD Server is a 2U high DMX generator, running the ZerOS Operating System and emulating
More informationRemote RadEye Product Family
Remote RadEye Product Family Overview The Remote RadEye x-ray camera provides the ultimate flexibility in design and product options for your complex imaging applications. Our unique camera design separates
More informationVME Data Acquisition System: Fundamentals and Beyond. Abhinav Kumar Bhabha Atomic Research Centre, Mumbai March 2011
VME Data Acquisition System: Fundamentals and Beyond Abhinav Kumar Bhabha Atomic Research Centre, Mumbai March 2011 Presentation Outline Chapter 1 -------------------------------- Introduction to VME Chapter
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationProduct Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac
Product Description Capacitor charger power supplies from Digital Power are designed to meet the exacting requirements of medical, aesthetic, and industrial pulsed energy systems. The modular design of
More informationUser s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR
User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR Content General safety summary...1 Introduction...2 Chapter 1 Getting started...3 System Requirements...4 Installing Hardware...5 Installing Software...8
More informationDDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
More information3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES
12.02 EA 4035-SERIES 3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES Splashproof 35,1x22,4 mm FEATURES * IP65 * 2 LED AND 2 LCD TYPES * EASY TO USE OR COMPATIBLE TO DATEL * ±200mV D.C. FULL SCALE READING
More informationMobile Communications DC Sources 40-100 W
40-100 W 66319B/D, 66321B/D Ideal for testing wireless and battery powered devices Several times improvement in measurement throughput over general purpose DC sources Superior output transient performance
More informationEPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels
Scanner Parts Start and indicator light Photo Print USB port The has a transparency unit built into the scanner lid and holder for 35 mm film and slides: EPSON Perfection 1650 owners can purchase an optional
More informationMagnet field- and Radiation Tolerant New Power Supply System PL500F8-12 MARATON
Magnet field- and Radiation Tolerant New Power Supply System PL500F8-12 MARATON Water-cooled Floating Power Supply with Monitoring & remote control to power readout or frontend electronics 24.11.03 LHCb
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
More informationDigital I/O: OUTPUT: Basic, Count, Count+, Smart+
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.
More informationThe software beyond the climatic. Environment simulation
Spirale 2 The software beyond the climatic Environment simulation Spirale 2... Take it easy! Spirale 2 is a new software, based on a reliable system (Windows NT) and if its performances are surprising,
More informationPortal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
More informationAdditional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
More informationRock-Ola Music Center Set-Up and Installation Guide For all Q-Series models 230V, Export
Part No. 61745-01 Rock-Ola Music Center Set-Up and Installation Guide For all Q-Series models 230V, Export IMPORTANT SAFETY INSTRUCTIONS a. Read these instructions. b. Keep these instructions. c. Follow
More informationCurrent Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
More informationRIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
More informationMassachusetts Institute of Technology
Objectives Massachusetts Institute of Technology Robotics: Science and Systems I Lab 1: System Overview and Introduction to the µorcboard Distributed: February 4, 2015, 3:30pm Checkoffs due: February 9,
More informationWahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationWEATHER STATION FOR SOLAR FARM MONITORING
WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.
More informationAgilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide
Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide Verify that you received the following items in the shipment of your handheld scope: 1 Power cable 1 Li-Ion battery pack, 10.8 V (included
More informationSeries 2220 Multichannel Programmable DC Power Supplies
Series 2220 Multichannel Programmable DC Power Supplies User s Manual www.keithley.com 2220S-900-01 Rev. C / December 2013 *P2220S90001C* 2220S-900-01C A Greater Measure of Confidence A Tektr onix Company
More informationTechnical Information Manual
Technical Information Manual Revision n.1 4 January 2004 Mod. Table of Contents TABLE OF CONTENTS... I 1 GENERAL DESCRIPTION...1 1.1 OVERVIEW...1 1.2 MAIN TECHNICAL SPECIFICATIONS...1 2 FUNCTIONAL DESCRIPTION...2
More information14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V
14.5GHZ 2.2KW CW GENERATOR GKP 22KP 14.5GHz WR62 3x400V UTILIZATION OF GKP 22KP GENERATOR With its characteristics of power stability whatever the load, very fast response time at a pulse, low ripple,
More informationSOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
More information