Miniature Contactors - CWC Series
|
|
- Edward Oliver
- 7 years ago
- Views:
Transcription
1 Overloads Relays Pushbuttons Miniature - CWC Series The CWC Series Mini Contactor Line is a Compact Solution for the Control and Operation of s. Its extensive lineup of modular and tool-free accessories makes this series the most flexible mini-contactor available today. The CWC Series miniature contactor features more horsepower for its size than any other miniature contactor on the market. Standard Features Direct Mounting to RW17D Series Thermal Overload Relays Direct Mounting to MPW18 and MPW40 Series Manual Low Consumption DC Coils Tool Free DIN Rail Mountable Frame size remains the same for C and DC coil contactors up to 16 Complete line of snap-on accessories Mounting Position of ll Compact CWC Catalog Number Sequence Miniature Contactor Series CWC: Miniature Contactor CWC: Control Relay 360 CWC Frame Rating lank: Control Relay (1th=10mps) 7:07mps 9:09mps 12:012mps 16:016mps 25:022mps Chart intended for reference only and not to create part numbers V18 uxiliary Contacts For CWC0 00: None 10: 1 NO 01: 1 NC For CWC0 22:2 NO + 2 NC 31:3 NO + 1 NC 13:1 NO + 3 NC 40:4 NO 04: 4 NC Coil Voltage VC COIL V04: 24Vac 60Hz V18: 120Vac 60 Hz V24: Vac 60 Hz V47: 480Vac 60Hz VDC Coil (Standard Consumption) C03: 24Vdc C12: 110Vdc VDC COIL (Low Consumption) L03:24Vdc Pole 00: Control Relay (4 auxiliary terminals) 30: CWCO with 3 NO Poles 22: CWCO with 2 NO + 2 NC Poles 40: CWCO with 4 NO Poles SK4WEG Data is subject to change without notice.
2 CWC Series - Miniature General Miniature contactors CWC Front auxiliary contact block FC0 3 - Mechanical interlock block IC0 4 - Surge supressor blocks RCC0 (RC), VRC0 (Varistor), DIC0 (Diode) 5 - Electronic timers TEC0, TDC0 and TETC0 6 - Mini contactor CWC Front auxiliary contact block FC Pushbuttons 4 Relays Overloads Data is subject to change without notice. WEG utomation - Products and Solutions 133
3 CWC Series - Miniature Overloads Relays Pushbuttons Type 3 poles CWC07 CWC09 CWC012 CWC016 CWC025 Rated operational power 1) Single-phase 115Vac Hp 1/3 1/3 1/ /2 230Vac Hp 3/ Three-phase 230Vac Hp 1 1/ /2 460Vac Hp / Vac Hp 5 7 1/2 7 1/ General Purpose Rating (C-1) Inductive Switching (C-3) Overload relay uxiliary contact blocks Mechanical interlock Timer Surge suppressor RW17-1D FC0-20 (2NO) FC0-22 (2NO + 2NC) FC0-11 (1NO + 1NC) FC0-04 (4NC) FC0-02 (2NC) FC0-31 (2NO + 1NC) FC0-40 (4NO) FC0-13 (1NO + 3NC) ICO ON-Delay (TECO) OFF-Delay (TDCO) Star-Delta (TETCO) RC block: RCC0-1 D V 50/60Hz RCC0-2 D V 50/60Hz RCC0-3 D V 50/60Hz RCC0-4 D V 50/60Hz RCC0-5 D V 50/60Hz RCC0-6 D V 50/60Hz FC (1NO+1NC) FC ( 2NO) FC (2NC) Varistor block: VRC0-1 E V 50/60Hz / 12-60VDC VRC0-2 E V 50/60Hz / VDC VRC0-3 E V 50/60Hz / VDC VRC0-4 E V 50/60Hz / VDC VRC0-5 D V 50/60Hz Diode block(cwc07-16): DIC0-1 C VDC RW17-2D _ Notes: 1) Some motor characteristics may vary according to each manufacturer SK4WEG Data is subject to change without notice.
4 Three Pole Miniature Contactor with C Coil CWC Series - Miniature General Single Phase Maximum UL Horsepower Three Phase uxiliary Contacts 115V 230V 200V 230V 460V 575V N.O. N.C. 1/3 3/4 1-1/2 1-1/ / /2 1/ /2 7-1/ Current Rating mps Catalog Number List Price 1 0 CWC * $ CWC * $ CWC * $ CWC * $ CWC * $ CWC * $ CWC * $ CWC * $70 1-1/ / CWC * $80 To complete the selection - Replace * with desired coil voltage from Coil Voltage Code Table Note: Other voltages available upon request. *C COIL VOLTGE CODE SELECTION 60 Hz 24V 120V V 480V CODE V04 V18 V24 V47 50 Hz - 110V V Three Pole Miniature with DC Coil Single Phase Maximum UL Horsepower Three Phase uxiliary Contacts 115V 230V 200V 230V 460V 575V N.O. N.C. 1/3 3/4 1-1/2 1-1/ / /2 1/ /2 7-1/ To complete the selection - Replace + with desired coil voltage from Coil Voltage Code Table Current Rating mps Catalog Number List Price 1 0 CWC $ CWC $ CWC $ CWC $ CWC $ CWC $ CWC $ CWC $79 +DC COIL VOLTGE CODE SELECTION Vdc 24V 110V 24V LOW CONSUMPTION* CODE C03 C12 L03 Multiplier Z6 Multiplier Z6 Relays Overloads Pushbuttons Data is subject to change without notice. WEG utomation - Products and Solutions 135
5 Overloads Relays Pushbuttons CWC Series - Miniature Four Pole with C Coil To complete the selection - Replace * with desired coil voltage from Coil Voltage Code Table Four Pole with DC Coil N.O. *C COIL VOLTGE SELECTION Main Contacts 60 Hz 24V 120V V 480V CODE V04 V18 V24 V47 50 Hz - 110V V To complete the selection - Replace + with desired coil voltage from Coil Voltage Code Table +DC COIL VOLTGE CODE SELECTION FOR CWC0_ Hz 24V 110V CODE C03 C12 N.C. 4 0 CWC * 2 2 CWC * 4 0 CWC * 2 2 CWC * 4 0 CWC * 2 2 CWC * N.O. Main Contacts +DC COIL VOLTGE SELECTION FOR CWCO_ Hz 24V 110V CODE R03 R12 N.C. 4 0 CWC CWC CWC CWC CWC CWC Catalog Number List Price Multiplier $48 $52 $70 Catalog Number List Price Multiplier $62 $68 $79 Z6 Z SK4WEG Data is subject to change without notice.
6 Miniature Control Relay CWC Series - Miniature General Current Rating mps Rating , Q600 To complete the selection - Replace * with desired coil voltage from Coil Voltage Code Table *C COIL VOLTGE SELECTION 60 Hz 24V 120V V 480V CODE V04 V18 V24 V47 50 Hz - 110V V Note: Other voltages available upon request. Miniature Control Relay with DC Coil Current Rating mps Rating , Q600 N.O. To complete the selection - Replace + with desired coil voltage from Coil Voltage Code Table +DC COIL VOLTGE CODE SELECTION Vdc 24V 110V 24V LOW CONSUMPTION* CODE C03 C12 L03 uxiliary Contacts N.C. Catalog Number List Price Multiplier 2 2 CWC * $ CWC * $ CWC * $ CWC * $ CWC * $45 N.O. uxiliary Contacts N.C. Catalog Number List Price Multiplier 2 2 CWC $ CWC $ CWC $ CWC $ CWC $59 Z6 Z6 Relays Overloads Pushbuttons Data is subject to change without notice. WEG utomation - Products and Solutions 137
7 CWC Series - Miniature Front uxiliary Contact lock For use with Max. number of contacts/ mini contactor uxiliary contacts NO NC Markings For use with CWC0 (3 pole) Catalog Number For use with CWC0 (4 pole) markings Catalog Number For use with CWC0 markings Catalog Number List Price Multiplier FC0-20 FC4-20 FC FC0-11 FC4-11 FC FC0-02 FC4-02 FC-02 $15 CWC CWC0 4 0 FC0-40* FC4-40* FC-40* 2 2 FC0-22* FC4-22* FC-22* Overloads Relays Pushbuttons *Low consumption 24Vdc contactors can only use 2 pole auxiliary contact blocks Mechanical Interlock lock 4 CWC FC0-04* FC4-04* FC-04* 3 1 FC0-31* FC4-31* FC-31* 1 3 FC0-13* FC4-13* FC-13* 2 0 FC FC FC Front Mounting Mechanical interlock without width increase llows assembly of auxiliary contact blocks, surge suppressor and timing relay For use with CWC CWC0 Catalog Number $26 $15 List Price Multiplier IC0 $10 Z6 Z SK4WEG Data is subject to change without notice.
8 RMCO Latch lock CWC Series - Miniature General Surge suppressors - Fast front mounting (clip on). - llows mounting with all the accessories. For use with diagram Voltage Catalog Number CWC CWC0 CWC CWC0 Front Mounting Mechanical interlock using 2 minicontactors (C or DC coil) Can be mounted with the following accessories: auxiliary contact block, surge suppressor and timers. Operation Description of Latch lock RMCO 24-48V 50/60Hz RCC0-2 D V 50/60Hz RCC0-3 D V 50/60Hz RCC0-4 D V 50/60Hz RCC0-6 D V 50/60Hz / 12-60VDC VRC0-1 E V 50/60Hz / VDC VRC0-2 E V 50/60Hz / VDC VRC0-3 E V 50/60Hz VRC0-5 D VDC For use with CWC CWC0 Catalog Number DIC0-1 C33 List Price List Price Multiplier RMCO $12 Z6 Multiplier $18 Z6 Relays Overloads Pushbuttons Data is subject to change without notice. WEG utomation - Products and Solutions 139
9 Overloads Relays Pushbuttons CWC Series - Miniature Electonic timing relay - Right-side fast mounting - Up to 30 minutes timing - LED status indication Functional Diagram Function Time Voltages Catalog Number On-Delay (TECO) Off-Delay (TDCO) Start-Delta (TETCO) 3-0,3 to 3 seconds TEC0-U003S-E to 10 seconds TEC0-U010S-E to 30 seconds TEC0-U030S-E V 60-6 to 60 seconds TEC0-U060S-E05 50/60Hz - DC to 100 seconds TEC0-U100S-E to 300 seconds TEC0-U300S-E to 1800 seconds TEC0-U030M-E V C/DC V C/DC 3-0,3 to 3 seconds TDC0-U010S-E04 TDC0-U003S-E to 10 seconds 24-60V 50/60Hz TDC0-U003S-E04 TDC0-U010S-E to 30 seconds - DC TDC0-U030S-E04 TDC0-U030S-E to 60 seconds V TDC0-U060S-E04 TDC0-U060S-E to 100 seconds 50/60Hz - DC TDC0-U100S-E04 TDC0-U100S-E to 300 seconds TDC0-U300S-E04 TDC0-U300S-E to 1800 seconds TDC0-U030M-E04 TDC0-U030M-E V 50/60Hz - DC TETC0-U030S-D to 30 seconds V 50/60Hz - DC TETC0-U030S-D V 50/60Hz - DC TETC0-U030S-D66 Functions On-Delay TEC0 Off-Delay TDC0 Start-Delta TETC0 Led On Led Off Diagrams List Price $150 $150 $130 Multiplier Z SK4WEG Data is subject to change without notice.
10 Printed oard Connector Easy-Connection usbar CWC Series - Miniature General Quick and easy assembly for wye-delta and reversing starters llows assemble of overload relay RW17D, manual motor protectors MPW18 & MPW40 and timer Wye-Delta Rating (HP) Contactor 230V 460V 575V K1=K2 K /2 7-1/2 CWC07 CWC /2 10 CWC09 CWC CWC012 CWC07 7-1/ CWC016 CWC09 Reversing Rating (HP) Contactor 230V 460V 575V K1=K2 1-1/2 5 5 CWC /2 CWC /2 7-1/2 CWC CWC016 For use with CWC CWC0 Catalog Number List Price ECCO-SD $34 ECCO-R $34 Pushbuttons Multiplier Z6 Relays Overloads Data is subject to change without notice. WEG utomation - Products and Solutions 141
11 Overloads Relays Pushbuttons CWC Series - Miniature General Data Catalog Number CWC0 CWC07 CWC09 CWC012 CWC016 CWC025 Standards IEC / UL 508 Rated insulation voltage Ui (pollution degree 3) IEC/EN , VDE 0660 (V) 690 UL, CS (V) 600 Rated impuse withstand voltage Uimp (IEC/EN ) (kv) 4 Rated operational frequency (Hz) Mechanical lifespan C coil Ops x DC coil Ops x Electrical lifespan Ie C-3 Ops x Degree of protection (VDE 0160) Mounting Main circuits Control circuits and auxiliary contacts IP20 IP20 Screw or DIN rail 35 mm Coil terminals 2 Vibration resistance Mechanical shock resistance (½ sinusoid = 11ms) mbient temperature Contactor open (g) 2 Contactor closed (g) 4 Contactor open (g) 6 Contactor closed (g) 10 Operation -25 C C Storage -55 C C Normal values Up to 3,000 m ltitude 90% Ie / 80% Ue 3,000 to 4,000 m 80% Ie / 75% Ue 4,000 to 5,000 m Control - lternating Current (C) Catalog Number CWC0, CWC CWC025 Rated insulation voltage Ui IEC/EN , VDE 0660 (V) 1,000 1,000 (pollution degree 3) UL, CS (V) Coils rated voltage 50 Hz (V) Coils rated voltage 60 Hz (V) Coils rated voltage 50/60 Hz (V) Coils rated voltage Coil operating limits (xus) Coil 60 Hz Coil 50/60 Hz verage consumption Coil 60 Hz Coil 50/60 Hz verage time Control - Direct Current (DC) Pick up (xus) Drop out (xus) Pick up (xus) Drop out (xus) x Us coil cold state Magnetic circuit closed (V) factor (cos ϕ) dissipation per pole (W) Magnetic circuit closing (V) factor (cos ϕ) Magnetic circuit closed (V) Magnetic circuit closing (V) Closing NO contacts (ms) Opening NO contacts (ms) Catalog Number CWC0, CWC CWC Coil type Conventional Low consumption 4P (2P/2R) Rated insulation voltage U i IEC/EN , VDE 0660 (V) 1,000 (pollution degree 3) UL, CS (V) 600 Standard voltages (V) Coil operating limits (xus) Pick up (xus) Drop out (xus) consumption Operation time 1.0 x Us coil cold state Magnetic circuit closed (W) Magnetic circuit closing (W) Closing NO contacts (ms) Opening NO contacts (ms) SK4WEG Data is subject to change without notice.
12 Technical Data CWC Series - Miniature Catalog Number CWC07 CWC09 CWC012 CWC016 CWC025 Rated operational current I e C-4 (U e 440 V) () C-3 (U e 440 V) () C-1 (θ 55 C, U e 690 V) () IEC/EN , VDE 0660 (V) 690 Rated operational voltage U e UL, CS 1) (V) 600 Rated thermal current Ith (θ 55 C) () Making capacity - IEC/EN () (U e 400 V) () reaking capacity (U IEC/EN e =500 V) () (U e =690 V) () Short-time current (no current flowing during recovery time of 10 min and θ 40 C) against short-circuits with fuses (gl/gg) 1 seg () seg () seg () seg () min () min () V - UL/CS 1) (k) 5 Coordination type 1 () Coordination type 2 () verage impedance per pole (mω) verage power dissipation per C-1 (W) pole C-3 (W) Utilization category Rated operational current Ie (θ 55 C) Rated operational power 1) Max. electrical operational per hour U e 440 V () U e 500 V () U e 690 V () U e 1,000 V () Not available 220 / 230 V (kw) (cv) / V (kw) (cv) / 415 V (kw) (cv) V (kw) (cv) V (kw) (cv) / 690 V (kw) (cv) ops./h (%) ,200 ops./h (%) ,000 ops./h (%) Utilization category C-4 Rated operational current I e C-4 (U e 440 V) () / 230 V (kw) (cv) / 400 V (kw) (cv) (kw) V Rated operational power 1) (cv) (200,000 operations) (kw) V (cv) V (kw) (cv) / 690 V (kw) (cv) General Relays Overloads Pushbuttons Note: 1) For 50/60 Hz three-phase, 4 poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design. Data is subject to change without notice. WEG utomation - Products and Solutions 143
13 Overloads Relays Pushbuttons CWC Series - Miniature Technical Data Catalog Number CWC07 CWC09 CWC012 CWC016 CWC025 Utilization category C-1 3P (NO) or 4P (4NO) Rated thermal current I th (θ 55 C) () Maximum operational current (up to 690 V) Maximum operational power θ 55 C 3-phase resistors Current values for connection of Percentage of the max. operational current at Maximum operational power θ 55 C (resistive load) UL Ratings θ 40 C () θ 55 C () θ 70 C () / 230 V (kw) / 400 V (kw) / 440 V (kw) V (kw) / 690 V (kw) poles in parallel I e x poles in parallel I e x poles in parallel I e x ops./h (%) 1,200 ops./h (%) 3,000 ops./h (%) SK4WEG Data is subject to change without notice P (NO/NC) or 4P (2NO + 2NC) 3P (NO) 2P (NO/NC) 220 / 230 V (kw) / 400 V (kw) / 440 V (kw) V (kw) / 690 V (kw) Catalog Number CWC07 CWC09 CWC012 CWC016 CWC / 600 V (HP) 5 7 1/2 7 1/ uilt-in uxiliary Contacts Catalog Number CWC CWC0 Standards IEC , IEC Rated insulation voltage U i (pollution degree 3) IEC, VDE 0660 (V) 690 UL, CS (V) 600 Rated operational voltage U e IEC, VDE 0660 (V) 690 UL, CS (V) 600 Rated thermal current I th (θ 55 C) () 10 Rated operational current I e C-15 (IEC ) UL, CS DC-13 (IEC ) UL, CS General purpose current (600 V) () phase 3-phase U e 240 V () V () V () V () V () V () 6 48 V () V () V () 0.7 Q600 Making capacity (rms) U e 400 V 50/60 Hz - C-15 () 10 x I e (C-15) reaking capacity (rms) U e 400 V 50/60 Hz - C-15 () 10 x I e (C-15) Max.fuse class gl-gg without welding (short-circuit protection) gl/gg 110 / 120 V (HP) 1/3 1/3 1/ /2 208 V (HP) 3/4 1/2 1/ / 240 V (HP) 3/4 1/ / 120 V (HP) 3/ / V (HP) 1 1/ / 240 V (HP) 1 1/ /2 440 / 480 V (HP) / () 10 Control circuit reliability (V / m) 17 / 5 Electrical endurance (millions operations) 1 Mechanical endurance (millions operations) 10
14 Technical Data uxiliary Contacts CWC Series - Miniature Catalog Number FC0 / FC025 Standards IEC , IEC Rated insulation voltage U i (pollution degree 3) IEC, VDE 0660 (V) 1,000 UL, CS 1) (V) 600 IEC, VDE 0660 (V) 690 Rated operational voltage U e UL, CS 1) (V) 600 Rated thermal current I th (θ 55 C) () 10 Rated operational current I e U e 240 V () V () 6 C-15 (IEC ) V () V () V () - UL, CS 1) V () 1.5 DC-13 (IEC ) 60 V () V () V () 0.4 UL, CS 1) Q600 Making capacity (rms) U e 400 V 50/60 Hz - C-15 () 30 reaking capacity (rms) U e 400 V 50/60 Hz - C-15 () 3 Max.fuse class gl-gg without welding (short-circuit protection) () 10 Control circuit reliability (V / m) 17 / 5 Electrical endurance (millions operations) 1 Mechanical endurance (millions operations) 10 Timing relay Rated insulation voltage (U i ) V 300 Supply voltage (U e ) Control voltage (U c ) only TDC0 - pag terminals 2-1 terminals V dc/ V ac 50/60 Hz (TEC0) V dc/ V ac 50/60 Hz (TDC0) V dc/ V ac 50/60 Hz (TDC0) V ac 50/60 Hz (TETC0) V ac 50/60 Hz (TETC0) V ac 50/60 Hz (TETC0) V dc/ V ac 50/60 Hz (TDC0) V dc/ V ac 50/60 Hz (TDC0) Voltage operational limits x Uc ( V ac) x Uc ( V dc) Consumption m 5 Minimum time for reset (recovery time) ms 650 Minimum control time (only TDC0) ms 50 Setting accuracy (% of the full scale value) % +/-5 Repeat accuracy % +/-1 Changeover time Y - ms 50 General Relays Overloads Pushbuttons Data is subject to change without notice. WEG utomation - Products and Solutions 145
15 CWC Series - Miniature Technical Data Capacity and Tightening Torque - and uilt-in uxiliary s Catalog Number CWC07...CWC016 / CWC0 CWC025 Screw type terminal and built-in auxiliary terminal 1) mm² Finely stranded with end sleeve 1x x M3x 8 Flat / Phillips Stranded and finely stranded without end sleeve 1x x Solid 1x x Finely stranded with end sleeve 1x x x M3.5x 9 Flat / Phillips Stranded and finely stranded without end sleeve 1x x x WG (UL) Tightening torque (N.m) Tightening torque (lb.in) (UL) Solid 1x x x Overloads Relays Pushbuttons Note: 1) uilt-in auxiliary terminals not available for CWC025. Capacity and Tightening Torque - Coil s Catalog Number Screw type Coil terminals mm² Finely stranded with end sleeve 1x x CWC07...CWC025 / CWC0 M3.5x 8 Flat / Phillips Stranded and finely stranded without end sleeve 1x x WG (UL) Tightening torque (N.m) 1.1 Tightening torque (lb.in) (UL) 10 Capacity and Tightening Torque - uxiliary Contact Catalog Number Screw type uxiliary contact block mm² Finely stranded with end sleeve 1x x FC0 / FC / FC4 / FC025 M3.5x9 Flat / Phillips Stranded and finely stranded without end sleeve 1x x WG (UL) Tightening torque (N.m) 1.1 Tightening torque (lb.in) (UL) 10 Capacity -, Coil and uxiliary Contact Solid 1x x Solid 1x x Catalog Number CWC07_S... CWC012_S / CWC0_S FC0_S / FC_S / FC4_S type Spring terminal terminal Finely stranded with end sleeve Solid mm² 2x x uxiliary contact block / built-in auxiliary terminal / or coil terminal Finely stranded with end sleeve Solid Solid or finely stranded with end sleeve mm² 2x x x WG SK4WEG Data is subject to change without notice.
16 Technical Data Utilization Category DC-1, DC-3 and DC-5 DC-1(L/R 1ms) Ue 24 V 48 V 60 V 125 V 220 V 440 V 600 V DC-5(L/R 15ms) U e 24 V 48 V 60 V 125 V 220 V 440 V 600 V Catalog Number Serie poles Data is subject to change without notice. Catalog Number CWC07 CWC09 CWC012 CWC016 CWC025 Serie poles CW07 CWC07 CWC09 CWC012 CWC016 CWC025 Rated operational current I e () DC-3(L/R 2.5ms) 1 serie pole load 2 serie poles load Catalog Number 3 serie poles load 4 serie poles CWC Series - Miniature CWC07 CWC09 CWC012 CWC016 CWC025 Rated operational current Ie () Ue Serie poles Rated operational current Ie () V V V V V V V load load load load WEG utomation - Products and Solutions 147 General Relays Overloads Pushbuttons
17 Overloads Relays Pushbuttons CWC Series - Miniature Technical Data Timing relay Rated insulation voltage (U i ) V 300 Supply voltage (U e ) Control voltage (U c ) only TDC0 - pg 25 Voltage operational limits Operation Description of Latch lock RMC0 or Miniature CWCH0 Latch miniature contactors K1 Functional Diagram CWCH RESET miniature contactors K2 K1 1 2 Latching miniature contactors K1 status of NO contacts (auxiliary and/or power) K2 1-2 terminals 2-1 terminals E1/1 E2/2 or Latch miniature contactors K1 RESET miniature contactors K2 2 x CWC / CWC0 + RMC0 fter a minimum pulse of 100ms on miniature contactors coil (K1), the RMC0 will keep K1 contacts switched on The miniature contactors K1 will only return to rest position after miniature contactors coil (K2) be energized by a releasing pulse The mechanical latch will always and only happen on miniature contactors (K1). Note: if RESET miniature contactors coil (K2) remains energized, the latching of miniature contactors (K1) is not enabled. V Open Time Minimum time to ensure mechanical latch > 100ms Closed V dc/ V ac 50/60 Hz (TEC0) V dc/ V ac 50/60 Hz (TDC0) V dc/ V ac 50/60 Hz (TDC0) V ac 50/60 Hz (TETC0) V ac 50/60 Hz (TETC0) V ac 50/60 Hz (TETC0) V dc/ V ac 50/60 Hz (TDC0) V dc/ V ac 50/60 Hz (TDC0) x Uc ( V ac) x Uc ( V dc) Consumption m 5 Minimum time for reset (recovery time) ms 650 Minimum control time (only TDC0) ms 50 Setting accuracy (% of the full scale value) % +/-5 Repeat accuracy % +/-1 Changeover time Y - ms 50 Open Time Time Minimum time to ensure mechanical unlatch > 100ms SK4WEG Data is subject to change without notice.
18 Technical Data Electrical Lifespan Number of operation Milhões de manobras (106) C-3 (U e 415 V ac e U e 440 V ac) C-4 (U e 440 V ac) 1 CW07 CWC07 CWC09 CWC012 CWC Series - Miniature CWC016 Rated Corrente operational de desligamento current I e () Ie () CWC025 General Relays Overloads Number of operation (106) 0.1 Pushbuttons 0.01 Data is subject to change without notice. CWC07 CWC CWC012 CWC016 reaking current Ic () WEG utomation - Products and Solutions 149 CWC025
19 CWC Series - Miniature Dimensions mm (in) CWC ND CWC0 TDCO TECO TETCO VRCO RCCO DICO Overloads Relays Pushbuttons CWC025 45/ [1.8] 9/ [0.4] TDCO TECO TETCO 58/ [2.3] RMCO & ICO 83/ [3.3] 56/ [2.2] FC SK4WEG Data is subject to change without notice.
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationRT series Miniature Printed Circuit Board Relays, Sockets and Accessories
s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More information34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
More information40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationUS Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationSwitching Devices Contactors and Contactor Assemblies Special Applications
Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationSKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More information80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationData Sheet. Electro-mechanical counters Hengstler 800 series
Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More information80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
More informationSolid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48
Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 0, RS 8 Zero switching AC Solid State Relay Direct copper bonding (DCB) technology in 25A and 0A types LED indication Clip-on IP 20 protection
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More information1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
More information60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationE-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationElesta Elektrotechnik AG industry relays and accessories
Elesta Elektrotechnik AG industry relays and accessories edition 003 table of contents SKR-industry relay 4 SKR-screw socket with accessories 4 SFR-industry relay 6 SFR-screw socket with accessories 7
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationSoft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D 40 16 E 0 VD00
Soft Starter Three Phase General Purpose Soft Starters Type RSGD Soft starting and soft-stopping of 3-phase squirrel cage motors 45mm wide IP20 housing Operational Voltage: RSGD40 (220-400V), RSGD60 (220-600V)
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationGeneral Purpose Relays Accessories. Accessories Miniature Relay PT
Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n
More informationFP2 Relay. The Best Relaytion
The Best Relaytion 2 pole telecom / signal relay Through Hole Type (THT) Polarized. Relay types: non-latching with1 coil latching with 1 coil latching with 2 coils Features Telecom / signal relay (dry
More informationTelemecanique Zelio Relay complementary and easy to assemble
Telemecanique Zelio Relay complementary and easy to assemble Get more with the world s Power & Control specialist RS interface relays Compact dimensions, enabling multiplication of contacts in electrical
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationPLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet 101780_en_02. 1 Description
PLC INERFCE With PD Relay, niversal Version INERFCE Data Sheet 780_en_02 PHOENIX CONC - 03/08 Description PLC-RS /2 relay modules, which can be used universally, comprise 6.2 mm basic terminal blocks and
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationRotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
More information