CATEGORY 6A UTP RJ45 SOLUTION

Size: px
Start display at page:

Download "CATEGORY 6A UTP RJ45 SOLUTION"

Transcription

1 CATEGORY 6A UTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Modular Jacks Clipsal titanium Keystone Jacks Clipsal titanium Patch Panels Clipsal titanium Cable Clipsal titanium Cable Management Panel - Deep Clipsal Side Rings

2 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION INTRODUCTION Clipsal titanium Category 6A UTP The Clipsal titanium Category 6A UTP system is designed to support 10G Base T applications, and offers a great solution for an installation requiring high-speed and high bandwidth. This solution includes cable, patch panels, patch cables, modular jacks, as well as faceplates and cable management, and offers excellent headroom. The Clipsal Titanium Category 6A UTP patched solution overcomes alien cross talk concerns through the use of shielded patch leads. This passive shielding helps prevent AXT at the patch panel. This system is designed to meet AXT standards when installed in high-density active equipment applications. The product is independently verified, and certificates are available on request. The Clipsal Lifetime Warranty is available upon application. 94

3 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION PATCH CORD Clipsal titanium Category 6A UTP Patch Cord The Clipsal titanium Series Category 6A Patch Cord is a superior product delivering the best network performance when used in conjucntion with this series of products. The patch cord is constructed of high grade cable and quality RJ45 plugs, and is designed to operate up to 500MHz. This enables it to operate successfully in a Category 6A UTP environment. RJ6AF8A10PL,BU MECHANICAL CHARACTERISICS Cable Gauge (AWG) 26 AWG Pair Count 4 Pair individually colour coded with filler and PVC jacket Sequence Wiring sequence T568 A Durability 750 mating cycles RJ45 Plug FCC Part 68 Subpart Contact Material Phosphor bronze with 50 micro-inches gold over 100 micro-inches nickel Fully compliant to AS/NZS 3080:2003, ISO/IEC Edition and ANSI/TIA/EIA-568-C Series Channel and Link Standards. PE insulation on conductors. PVC outer jacket material. Available in multiple lengths. Backward compatible with Category 5e and 6 products. Designed to mitigate ANEXT. Snag-free design. Strain relief boot. Current Rating Insulation Contact Resistance 2.0 A maximum 500MΩ minimum 20MΩ maximum Performs to Category 6A international standards. Comes in various lengths to assist with better cable management. Backward compatible with Category 5e and 6. LINE DRAWING CATALOGUE NUMBER DESCRIPTION RJ6AF8A10PL,BU Patch Cord Category 6A 568A 1.0m RJ6AF8A20PL,BU Patch Cord Category 6A 568A 2.0m RJ6AF8A30PL,BU Patch Cord Category 6A 568A 3.0m RJ6AF8A50PL,BU Patch Cord Category 6A 568A 5.0m 95

4 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION PATCH CORD Clipsal titanium Category 6A UTP Patch Cord Low Smoke Zero Halogen The Clipsal titanium Series Category 6A Patch Cord is a superior product delivering the best network performance when used in conjunction with other Clipsal titanium Category 6A products. The patch cord is constructed of high grade cable and quality RJ45 plugs, and is designed to operate up to 500MHz. This enables it to operate successfully in a Category 6A environment. Clipsal Datacomms has released a range of PVC free, Low Smoke Zero Halogen (LSZH) Category 6A LAN cable and patch cords. The LSZH sheath is composed of thermoplastic and thermoset compounds that emit limited smoke and zero halogens (poisonous gases) when exposed to high sources of heat or fire and are PVC free. Clipsal titanium 4 Pair LSZH Category 6A LAN Cable and patch cords are superior products delivering excellent network performance and a "greener" peace of mind. More LSZH and RoHS products are being used as networks move toward a "greener" workplace and environment. MECHANICAL CHARACTERISICS Cable Gauge 26 AWG Pair Count 4 Pair individually colour coded with filler and LSZH jacket Sequence Wiring sequence T568 A Durability 750 mating cycles RJ45 Plug FCC Part68 Subpart F Plug Boot LSZH Contact Material Phosphor bronze with 50 micro-inches gold over 100 micro-inches nickel RJ6A8A10LPL, BU Cable sheath complies with IEC C (HF3) Fully compliant to AS/NZS 3080:2003, ISO/IEC Edition and ANSI/TIA/EIA-568-C Series Channel and Link Standards. UL CMR fire rated jacketing. PE insulation on conductors. Designed to mitigate ANEXT. Performs to Category 6A international standards. Comes in various lengths to assist with better cable management. Backward compatible with Category 5 and 6 products. Complies to LSZH requirements. Current Rating Insulation Contact Resistance 2.0 A maximum 500MΩ minimum 20MΩ maximum LINE DRAWING 96 CATALOGUE NUMBER DESCRIPTION RJ6AF8A10LPL,BU Patch Cord Category 6A LSZH 568A 1.0m RJ6AF8A20LPL,BU Patch Cord Category 6A LSZH 568A 2.0m RJ6AF8A30LPL,BU Patch Cord Category 6A LSZH 568A 3.0m RJ6AF8A50LPL,BU Patch Cord Category 6A LSZH 568A 5.0m

5 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION JACKS Clipsal titanium Category 6A UTP Jacks Modular - Suits Clipsal Wall Plates A C B The Clipsal titanium range of products are the next generation of data communications solutions. These modular jacks are colour coded for both 568A and 568B Standards and can be terminated using a Clipsal 110 tool (recommended). Clear wire retaining caps are supplied and can be used to provide additional cable strain relief. DIMENSIONS Product A B C 30RJ45SM6AF 23mm 23mm 35mm COLOUR AVAILABILITY 30RJ45SMA6A Fully compliant to AS/NZS 3080:2003, ISO/IEC , and ANSI/TIA/EIA-568-C Series. Backward compatible with Category 5e and Category 6 products. Flexible locking tabs. Compatible with Clipsal 110 tool. UL rated. Accepts solid AWG diameter conductors. Copper shielded shutter cap to eliminate alien crosstalk associated with Category6A. White (WE) Black (BK) Dielectric Strength Current Rating Insulation Resistance Contact Resistance Temperature Range Transmission Performance 1,000V RMS at 60Hz for 1 minute 1.5 A maximum 200MΩ minimum 1MΩ per contact -40 C to +70 C ISO/IEC Class EA AS/NZS 3080:2003 Class EA Various colours for easier circuit identification. Can be used in Multi-user Telecommunication Outlet applications (MUTO) and Consolidation Points (CP). Clear IDC caps that allow for termination verification and assist in cable retention. Modular Connector RJ45 8-Pin Connector FCC part 68, Subpart F and IEC compliant Durability 750 insertion cycles minimum Material Phosphor bronze with 50 micro- inches of gold over 100 micro-inches nickel plating Suitable insulation of 22 to 24 AWG (0.64 to 0.41mm) Insulation Diameter (Wire) mm Connector Material Phosphor bronze with nickel plating IDC Body and Cover Material Fire-Retardant UL 94V-0, Plastic CATALOGUE NUMBER DESCRIPTION 30RJ45SMA6A, (XX) Connector RJ45 Category 6A Keystone (XX) for colour: (WE) White Electric and (BK) Black 97

6 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION JACKS Clipsal titanium Category 6A UTP Jacks Keystone A C The Clipsal titanium Series Category 6A FTP Keystone Jack is a superior product delivering the best network performance when used in conjunction with other products in this range. The Clipsal titanium range of products are the next generation of data communications solutions. These FTP modular jacks are colour coded for both 568A and 568B standards. The FTP Jack features an easy to install tool-less design. DIMENSIONS Product A B C RJ45SMA6 23mm 15mm 36mm COLOUR AVAILABILITY B RJ45SMA6 Fully compliant to AS/NZS 3080:2003, ISO/IEC , ANSI/TIA/EIA-568-C Series and ANSI/TIA/EIA 568-B.2-10 (draft) Connecting Hardware Standards. Backward compatible with Category 5e and Category 6. Compatible with Clipsal 110 tool. UL 94V-0 rated. Accepts solid AWG diameter conductors. Various colours for easier circuit identification. Can be used in Multi-user Telecommunication Outlet applications (MUTO) and Consolidation Points (CP). Clear IDC caps that allow for termination verification and assist in cable retention. White (WE) Black (BK) Dielectric Strength Current Rating Insulation Resistance Contact Resistance Temperature Range Transmission Performance 1,000V RMS at 60Hz for 1 minute 1.5 A maximum 200MΩ minimum 1MΩ per contact -40 C to +70 C Exceeds ISO/IEC Class EA AS/NZS 3080:2003 Class EA Modular Connector RJ45 8-Pin Connector FCC part 68, Subpart F and IEC compliant Durability 750 insertion cycles minimum Material Phosphor bronze with 50 micro- inches of gold over 100 micro-inches nickel plating Suitable insulation of 22 to 24 AWG (0.64 to 0.41mm) Insulation Diameter (Wire) mm Connector Material Phosphor bronze with nickel plating IDC Body and Cover Material Fire-Retardant UL 94V-0, Plastic 98 CATALOGUE NUMBER DESCRIPTION RJ45SMA6, (XX) Connector RJ45 Category 6A Keystone (XX) for colour: (WE) White Electric and (BK) Black

7 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION PATCH PANELS Clipsal titanium Category 6A UTP Patch Panels 24 Port The Clipsal titanium range of patch panels feature individual Category 6A Modular Jacks that are colour coded for both 568A and 568B standards and can be terminated using a Clipsal 110 tool (recommended). Dielectric Strength Current Rating Insulation Resistance Contact Resistance Temperature Range Transmission Performance 1,000V RMS at 60Hz for 1 minute 1.5 A maximum 200MΩ minimum 1MΩ per contact -40 C to +70 C ISO/IEC Class EA AS/NZS 3080:2003 Class EA Modular Connector RJ45 8-Pin Connector FCC part 68, Subpart F and IEC compliant Durability 1000 mating cycles Material Phosphor bronze with 50 micro inches of gold over 100 micro-inches nickel plating Suitable insulation of 22 to 24 AWG (0.64 to 0.41mm) Insulation Diameter (Wire) mm Durability 10 insertions of any combination of wire gauge - two wires per slot Connector Material Phosphor bronze with nickel plating IDC Body and Cover Material Fire-Retardant, UL 94V-0, Plastic Powder-coated metal framework. Universal colour coding for 568A and 568B Standards. Removable rear cable management tray. Compatible with standard 19 equipment frames. IDC termination using Clipsal 110 Tool. Fully compliant to AS/NZS 3080:2003, ISO/IEC , and ANSI/TIA/EIA-568-B Series Connecting Hardware Standards. Individual removable modular jacks. Complete with all mounting and cable fixing hardware. Rear cable management tray is supplied loose, allowing the installer to fit after termination. The front labelling system provides a clear and efficient means of identifying circuits. Powder coated metal frame is robust and protects the patch panel from corrosion and scratching. Compliance with international standards gives the customer peace of mind that their network will perform to link, channel and application requirements. CATALOGUE NUMBER RJ6AA1/24PP DESCRIPTION Patch Panel, 24 Port, Category 6A, 568A/B 99

8 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION PATCH PANELS Clipsal titanium Category 6A UTP Patch Panel Angled 24 Port The Clipsal titanium range of patch panels feature individual Category 6A Modular Jacks that are colour coded for both 568A and 568B standards and can be terminated using a Clipsal 110 tool (recommended). Dielectric Strength Current Rating Insulation Resistance Contact Resistance Temperature Range Transmission Performance 1,000V RMS at 60Hz for 1 minute 1.5 A maximum 200MΩ minimum 1MΩ per contact -40 C to +70 C Exceeds ISO/IEC Class E AS/NZS 3080:2003 Class E Modular Connector RJ45 8-Pin Connector FCC part 68, Subpart F and IEC compliant Durability 1000 mating cycles Material Phosphor bronze with 50 micro inches of gold over 100 micro-inches nickel plating Suitable Insulation of 22 to 24 AWG (0.64 to 0.41mm) Insulation Diameter (Wire) mm Durability 10 insertions of any combination of wire gauge - two wires per slot Connector Material Phosphor bronze with nickel plating IDC Body and Cover Material Fire-Retardant, UL 94V-0, Plastic Powder-coated metal framework. Universal colour coding for 568A and 568B Standards. Removable rear cable management tray. Compatible with standard 19 equipment frames. IDC termination using Clipsal 110 Tool. Fully compliant to AS/NZS 3080:2003, ISO/IEC , and ANSI/TIA/EIA-568-B Series Connecting Hardware Standards. Individual removable modular jacks. Complete with all mounting and cable fixing hardware. Rear cable management tray is supplied loose, allowing the installer to fit after termination. The front labelling system provides a clear and efficient means of identifying circuits. Powder coated metal frame is robust and protects the patch panel from corrosion and scratching. Compliance with international standards gives the customer peace of mind that their network will perform to link, channel and application requirements. 100 CATALOGUE NUMBER RJ6AA1A24PP DESCRIPTION Patch Panel Angled, 24 Port, Category 6A, 568A/B Front Cable Management

9 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION CABLE Clipsal titanium Category 6A UTP Cable Clipsal titanium 4-Pair Category 6A UTP Cable delivers excellent network performance when used in conjunction with other Clipsal titanium Category 6A UTP products. The Category 6A UTP cable consists of four pairs of solid insulated copper 24 AWG (0.57mm) and is UL listed with a CM fire rating. It is designed for use in horizontal cabling situations and supplied in 305m (1,000ft) lengths. The Category 6A UTP cable provides a significant margin above the minimum Category 6A near end crosstalk (NEXT) requirement of TIA/EIA 568-B.3-1 and ISO/IEC D4P6AIPV3R PHYSICAL SPECIFICATIONS Rated Temperature ( C) 75 Product Standard Certification UL File E Flammability Test CM Application Horizontal wiring in LAN Reference Standard EIA/TIA568 and ISO/IEC 11801, IEC CONSTRUCTION Conductor Solid bare copper AWG 23 Conductor Dia. Nom. (mm) 0.60 Insulation PE Average Thickness (mm) 0.22 Min Point Thickness (mm) 0.18 Insulation Diameter (±0.10mm) 1.05 Twisting Lay Length (mm) 30 underneath Cabling Lay Length (mm) 200 underneath Filler PE Jacket PVC Rip Cord YES Test Object Jacket Test Material PVC Before Tensile Strength (Kg/mm 2 ) 13.8 Aging Elongation (%) 100 Aging Condition ( C x hrs) 100 x 240 After Tensile Strength (Mpa) 85% of unaged Aging Elongation (%) 50% of unaged Cold Bend (-20± 2 C x 4 hrs) No crack Frequency (MHz) Attenuation (db/100m) NEXT (db) PSNEXT (db) ELFEXT (db/100m) PSELFEXT (db/100m) RL Delay PSANEXT PSAACRF MHz Input Impedance (Ohms) MHz Delay Skew (ns/100m) Pair-to-Ground Capacitance Unbalance (pf/100m) Max. Conductor DC Resistance 20 C (Ohms/km) 100 ± CATALOGUE NUMBER 2D4P6AIPV3R,BU DESCRIPTION 4 Pair Unscreened UTP Category 6A LAN Cable, 305m reel (Blue Only) 101

10 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION CABLE Clipsal titanium Category 6A UTP Cable Low Smoke Zero Halogen Clipsal titanium 4-Pair Category 6A UTP LSZH Cable delivers excellent network performance when used in conjunction with other Clipsal titanium Category 6A UTP products. The Category 6A UTP LSZH cable consists of four pairs of solid insulated copper 24 AWG (0.57mm) and is UL listed with a CM fire rating. It is designed for use in horizontal cabling situations and supplied in 305m (1,000ft) lengths. The Category 6A UTP LSZH cable provides a significant margin above the minimum Category 6A Near End Crosstalk (NEXT) requirement of TIA/EIA 568-B.3-1 and ISO/IEC D4P6AILS3R,BU PHYSICAL SPECIFICATIONS Rated Temperature ( C) 75 Product Standard Certification UL File E Flammability Test CM Application Horizontal wiring in LAN Reference Standard EIA/TIA568 and ISO/IEC 11801, IEC CONSTRUCTION Conductor Solid bare copper AWG 23 Conductor Dia. Nom. (mm) 0.60 Insulation PE Average Thickness (mm) 0.22 Min. Point Thickness (mm) 0.18 Insulation Diameter (±0.10mm) 1.05 Twisting Lay Length (mm) 30 underneath Cabling Lay Length (mm) 200 underneath Filler PE Jacket LSZH Rip Cord YES Test Object Jacket Test Material LSZH Before Tensile Strength (Kg/mm 2 ) 13.8 Aging Elongation (%) 100 Aging Condition ( C x hrs) 100 x 240 After Tensile Strength (Mpa) 85% of unaged Aging Elongation (%) 50% of unaged Cold Bend (-20± 2 C x 4 hrs) No crack Frequency (MHz) Attenuation (db/100m) NEXT (db) PSNEXT (db) ELFEXT (db/100m) PSELFEXT (db/100m) RL Delay PSANEXT PSAACRF MHz Input Impedance (Ohms) MHz Delay Skew (ns/100m) Pair-to-Ground Capacitance Unbalance (pf/100m) Max. Conductor DC Resistance 20 C (Ohms/km) 100 ± CATALOGUE NUMBER 2D4P6AILS3R,BU DESCRIPTION 4 Pair Unscreened UTP Category 6A LAN Cable, 305m reel (Blue Only)

11 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION CABLE MANAGEMENT Clipsal titanium Cable Management Panel Deep The Clipsal titanium Cable Management Panel is a 1 rack unit (1RU) item designed for use in 19 rack environments, managing patch cords that are connected between patch panels and/or active switches. The product is recommended for mounting between every second row of patch panels/active switches. The unique clips provide a quick and simple means of installing the panel in the rack or cabinet. The rings have been designed to facilitate easy insertion and removal of the patch leads, necessary in dynamic environments where moves and changes are required. DIMENSIONS Product A B C RJ1UCMPC 44mm 48mm 100mm Clipsal titanium styling RJ1UCMPC A B Rack Clips for easy mounting C RJ1UCMPC Reinforced cable rings Clip on cover (patented). Rack mount clips eliminate the need for cage nuts and screws. Cavities behind each ring provide additional space for cable slack. Additional depth on cable rings ensures compliance with minimum bend radius requirements. Complements Clipsal titanium patch panel styling. 100mm cable ring depth. Quick product installation using rack mount clips. CATALOGUE NUMBER RJ1UCMPC DESCRIPTION 1RU Clipsal titanium Cable Management Panel, Deep 103

12 CLIPSAL DATACOMMS CATEGORY 6A UTP RJ45 SOLUTION CABLE MANAGEMENT Clipsal Side Rings The side rings are typically used in frames or cabinets to provide vertical patch cord management. These rings have several features that make them stand out. The ring and lock design utilises proven plastic hinge technology to guide patch cords. These rings have unique teeth locks that are easy to open and snap back to lock tight again should you need to open the rings. The rings can be mounted with patch panels or directly onto the vertical panel mounts (VPM) of the equipment frame. Test Object Jacket Ring Material Polypropylene, Graphite Grey RJ1HUDSR DIMENSIONS Product Height Width Depth RJ1HUSSR 42mm 43mm 65mm RJ1HUDSR 42mm 43mm 130mm RJ1HUSSR Graphite Grey. Teeth locks that provide easy access and security for patch cords. Available in 1RU deep and shallow versions. The key benefit is the ring and lock design which not only makes the loading and unloading of patch cords or cables easier but also secures them in place, keeping the cabinet neat and uncluttered. This makes circuit identification and administration for the customer far more efficient. The two rings depths enable the customer to manage the cabinet or rack better depending on the amount of patch cords being used. 104 CATALOGUE NUMBER RJ1HUSSR RJ1HUDSR DESCRIPTION 1RU Shallow Side Ring 1RU Deep Side Ring

Communication, Signal & Data Cables

Communication, Signal & Data Cables Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

Innovative Connectivity Solution for Maximum Performance and Security

Innovative Connectivity Solution for Maximum Performance and Security Innovative Connectivity Solution for Maximum Performance and Security Financial Institutions Supports high performance backbone which enables transfer of real-time financial information through voice,

More information

Specification SFTP CAT6 Network Cable 23AWG CU

Specification SFTP CAT6 Network Cable 23AWG CU Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

Category 6 UTP - Cabling System

Category 6 UTP - Cabling System AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP

More information

Accelerating Light. Copper Cabling Solutions. Category 6A

Accelerating Light. Copper Cabling Solutions. Category 6A Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions

More information

Standards Affecting a Premise T-1 Installation

Standards Affecting a Premise T-1 Installation Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity

More information

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission

More information

E Series. E Series. Category 6 and 5e. Features

E Series. E Series. Category 6 and 5e. Features E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

Copper Systems Contents

Copper Systems Contents Copper Systems Copper Systems Contents Augmented Category 6 Systems 10GPlus Page 1.3 Category 7 Systems U-MediaPlus Page 1.11 Category 6 Systems Cat6Plus Page 1.13 Category 5e Systems GigaPlus Page 1.29

More information

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.

More information

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Introduction The purpose of this document is to: 1) provide background information beneficial to specifiers

More information

Ethernet Cat 5e & Cat 6 Patch Panels

Ethernet Cat 5e & Cat 6 Patch Panels Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

ADC Structured Cabling Solutions

ADC Structured Cabling Solutions ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution

More information

Always with Our Customers

Always with Our Customers LS Simple TM Structured Cabling System 2010 LS Cable, Ltd. All right reserved Ver 01. Jan.1001 Always with Our Customers www.lssimple.com 12F~17F, LS Tower, 10266, Hogyedong, Dongangu, Anyangsi, Gyeonggido,

More information

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope.

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope. SYSTIMAX Solutions GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions www.commscope.com The SYSTIMAX GigaSPEED X10D Shielded Solution provides unprecedented performance

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling

More information

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits INTRODUCTION The Radiall Type 43 coaxial connector range The Radiall range of Type 43 series connectors is fully approved (where applicable) to BT (British Telecom) standards as well as to British Standard

More information

Copper Patch Cords. Impact On Network Performance and Reliability

Copper Patch Cords. Impact On Network Performance and Reliability Copper Patch Cords Impact On Network Performance and Reliability 1 The Impact of Copper Patch Cords on Network Performance and Reliability As network infrastructures continue to have a higher impact on

More information

IT Cabling Solutions

IT Cabling Solutions IT Cabling Solutions Signamax & Hitachi Cable America System Performance Signamax & Hitachi Cable America (Hitachi) system quality assurance testing is based on the worst-case model - four-connector 100-meter

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up

More information

Gulf Cable & Electrical Ind. Co.

Gulf Cable & Electrical Ind. Co. CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

MapIT G2 Infrastructure Management

MapIT G2 Infrastructure Management MapIT G2 Infrastructure Management Introducing MapIT G2, a complete upgrade of Siemon s popular MapIT intelligent infrastructure management (IIM) solution. MapIT G2 integrates a powerful combination of

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially

More information

108-93018 05 APR 2016 Rev M

108-93018 05 APR 2016 Rev M Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can

More information

Copper Pre-terminated Assemblies

Copper Pre-terminated Assemblies Copper Pre-terminated Assemblies Copper Pre-Terminated Trunk Assemblies Overview Copper Pre-Terminated trunk assemblies are the perfect solution for Enterprise / Premise & Data Centre applications where

More information

INTELLIGENT INFRASTRUCTURE MANAGEMENT

INTELLIGENT INFRASTRUCTURE MANAGEMENT F/ System F/ Assemblies, 9.0 W W W. S I E M O N. C O M SECTION CONTENTS System...............................9. IM Software........................... 9. Analyzers..............................9. System

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

CABLE SPECIFICATION CAN CAB RJ45-SUBD9 CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector

More information

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security PANDUIT TX6 GIG SHIELDED COPPER CABLING SYSTEM Innovative Connectivity Solution for Maximum Performance and Security Gigabit Ethernet over Copper With ever increasing bandwidth requirements, advancements

More information

Panduit 28 AWG Patch Cords Installation Guideline

Panduit 28 AWG Patch Cords Installation Guideline Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure

More information

Standard Buccaneer - USB

Standard Buccaneer - USB IP68 rated USB version 2.0 performance Plug and play capability Visual mating indication Shielded system Single and double ended cables Screw coupling PCB versions Dust and waterproof sealing when mated

More information

7.1 id Intelligent Infrastructure Management. 7.2 id Active

7.1 id Intelligent Infrastructure Management. 7.2 id Active 7 HellermannTyton has a range of hardware products for use with Intelligent Infrastructure Management software. Page Page 7.1 Intelligent Infrastructure Management Category 6 Patch Leads 194 Category 5e

More information

LS Data Communication Product

LS Data Communication Product www.lscable.com 2007 LS Cable, Ltd. All right reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation.

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification

ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification Abstract Presented in this document are the standards to implement Electrical & Optical Ethernet components, cabling, connections,

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

Network Engineers Everywhere:

Network Engineers Everywhere: Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable

More information

Developing the Green Data Center

Developing the Green Data Center Products and Solutions to Support Energy Efficiency Ordering Guide Table of Contents Developing the Green Data Center Introduction...5 Airflow Management in the Data Center...6 Angled Panels Glide Cable

More information

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission

More information

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE

More information

B. PART 1 - GENERAL of SECTION 271300 BACKBONE COMMUNICATIONS CABLING shall also apply to this section.

B. PART 1 - GENERAL of SECTION 271300 BACKBONE COMMUNICATIONS CABLING shall also apply to this section. SECTION 271500 - HORIZONTAL UTP CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

MICROCABLES. A complete vision of your connectivity needs. Catalogue

MICROCABLES. A complete vision of your connectivity needs. Catalogue MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

SMARTen 24 UTP Patch Panels

SMARTen 24 UTP Patch Panels Features High density, 24 ports per 1U High performance, supportable bandwidth up to 500MHz supporting IEEE 802.3an 10Gbps application Special cap design for minimizing Alien Cross-Talk Conform to ANSI/TIA/EIA-568-B.2-10,

More information

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard. WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of

More information

Developing the Green Data Centre

Developing the Green Data Centre Products and Solutions to Support Energy Efficiency Ordering Guide Table of Contents Supporting the Green Data Centre Table of Contents Introduction...5 Airflow Management in the Data Centre...6 Angled

More information

The 10G wiring system

The 10G wiring system Edition 03.2010 The 10G wiring system Contents Page ITplus wiring system 2 3 Installation cables 4 5 Distribution equipment 6 7 Connecting technology 8 Connecting boxes 9 10 Patch cables 11 12 Wiring system

More information

RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009

RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009 RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical

More information

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification

More information

Copper Cabling Infrastructure Offering

Copper Cabling Infrastructure Offering Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

More information

Cat. 6 A EL Incredibly fast Get more

Cat. 6 A EL Incredibly fast Get more Cat. 6 A EL Incredibly fast Get more Productive Intuitive installation Reliable Dependable connection Flexible Wide range of applications Productive. Intuitive installation. Just a few flicks of the wrist

More information

SMA Connectors. RF Coax Connectors. Product Facts

SMA Connectors. RF Coax Connectors. Product Facts SMA Connectors Product Facts Performance to 12.4 GHz and beyond Available in various base metal options, including stainless steel, brass and zinc diecast Uses industry standard crimp tools and processes

More information

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned) 1 1 9.41 115 0 Patch cables are used 143 12 Fibre MTP Jumper, MTP (non-pinned) to Patch cables are used for non -permanent connections between patch panels, transmission equipment, etc. Pre -assembled

More information

Terminating 25-Pair Cable and 4-Pair Cross Connects

Terminating 25-Pair Cable and 4-Pair Cross Connects Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A C6 A modul and C6 A modul K The new connection system for all applications of course with Cat.6 A Intelligent solution for structured cabling systems There is an enormous need for high data transfer rates

More information

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies Patch Cords / Cable / Cable Assemblies Premise Connectivity Systems Patch Cords/Cable/ Cable Assemblies w w w. s i g n a m a x. c o m Category 6A 10G Patch Cords C1 Patch Panels and Cross- Category 6 Patch

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

3M Integrated Splitter Block BRCP-SP

3M Integrated Splitter Block BRCP-SP The Network of Networks 3M Integrated Splitter Block BRCP-SP The 3M Integrated Splitter Block BRCP-SP is the latest generation of the Cross Connect System BRCP developed by 3M specifically for xdsl and

More information

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION TÜRK TELEKOMÜNİKASYON KASYON A.Ş. DIRECTORSHIP OF OPERATION AND MAINTENANCE Operation Directorate of Access Networks INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION ANKARA 2008 CONTENTS 1.

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

SMARTen 24 STP Patch Panels

SMARTen 24 STP Patch Panels Features Support 24 ports per 1U High performance, supportable bandwidth up to 500MHz supporting IEEE 802.3an 10Gbps application Conform to ANSI/TIA/EIA-568-B.2-10, ISO/IEC 11801 2.1 edition and CENELEC

More information

INTRODUCTION KRONE HIGHBAND. KRONE has a long history as a market leader in the communications and information industry.

INTRODUCTION KRONE HIGHBAND. KRONE has a long history as a market leader in the communications and information industry. INTRODUCTION KRONE has a long history as a market leader in the communications and information industry. Founded in 1928 by Gustav Krone, the KRONE Group is one of the world s leading suppliers of the

More information

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8 Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category

More information

.093 [2.36] Commercial Pin and Socket Connectors

.093 [2.36] Commercial Pin and Socket Connectors Product Facts Polarized Cavity identification Low contact-mating force Dual locking lances Detent and positive locking Contacts available in brass and phosphor bronze with tin and gold plating Panel mounting

More information

Quick Reference Guide Euro Style Terminal Blocks

Quick Reference Guide Euro Style Terminal Blocks Quick Reference Guide Euro Style terminal block connectors feature various wire termination methods including rising cage clamp, wire protector, spring, IDC and crimp snap. The design of terminal block

More information

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems Asef Baddar, RCDD Principal Engineer / Applications Engineering Supervisor Leviton Network Solutions C/7 - #1928 Table of Contents Background

More information

COAXICON Contacts. RF Coax Connectors. Product Facts

COAXICON Contacts. RF Coax Connectors. Product Facts COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI) within the Unified Physical Infrastructure SM (UPI) www.panduit.com WP-11 April 2007 Introduction With the ratification of the IEEE 802.3an 10GBASE-T copper standard, end users now have more media options

More information

Physical Layer Management

Physical Layer Management Introduction...7.2 Patch Panels...7.3 Active Hardware...7.9 Software...7.11 7.1 Introduction TrueNet Physical Layer Management TrueNet PLM combines our leading connectivity technology with Intelligent

More information

RJF TV Ethernet connection system for harsh environment

RJF TV Ethernet connection system for harsh environment RJF TV Ethernet connection system for harsh environment ROHS compliant N & BZ RJFTV allows you to use an Ethernet Class D / Cat. 5e connection for 10 BaseT, 100 BaseTx or 1000 BaseT networks in harsh environments.

More information

HARAX circular connector

HARAX circular connector Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor

More information

Application Specification SIAMEZE * Standard and 114-13166 Fine Range Terminals 18 Mar 11 Rev C

Application Specification SIAMEZE * Standard and 114-13166 Fine Range Terminals 18 Mar 11 Rev C Application Specification SIAMEZE * Standard and 4-66 Fine Range Terminals 8 Mar Rev C NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters

More information

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects. FC black process black LockPORT Security Patch Cables CAT5e, CAT6 and Fibre 5th black Secure network ports from unauthorized access and accidental disconnects. BLACK BOX» LockPORT cables stay locked in

More information

Cabling for 10GBASE-T and Beyond - A Tangled Web

Cabling for 10GBASE-T and Beyond - A Tangled Web Augmented Category 6 Category 6 A CLC TR 50173-99-1 TIA/EIA-TSB-155 TIA/EIA-568-B.2-10 ISO/IEC 11801 A1.1 Class E A Class F A ISO/IEC 11801 A1.2 Category 7 A ISO/IEC TR 24750 ISO/IEC 11801 Cabling for

More information