1 White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems Asef Baddar, RCDD Principal Engineer / Applications Engineering Supervisor Leviton Network Solutions C/7 - #1928

2 Table of Contents Background 3 Application Usage 3 Topology and Cabling Challenge 4 Cabling Standards Role 4 Cabling Progress 5 Summary 6 extreme 10G 7 2

3 Background - LAN Speeds Ever-Increasing, New Systems Needed LAN speeds have migrated steadily upward from 100BASE-T in the early 1990s to 1000BASE-T (Gigabit Ethernet) in In June 2006, IEEE (Institute of Electrical and Electronic Engineers) ratified a new standard called 10GBASE-T through the Task Force 802.3an. Their charter was the technical development of a new Physical Layer (PHY) that will be defined for operation up to10 Gigabit per second over twisted pair copper links. 10GBASE-T will extend the Ethernet family with speeds 10 and 100 times greater, respectively, than current LAN speeds. The objective of the 802.3an standard is to provide support for: bit error rate (BER) 10 Gigabit/second data transmission over up to 55 meters of Class E cabling (Category 6) 10 Gigabit/second data transmission over at least 100 meters of Class EA (Category 6A) and Class F (Category 7) cabling Application Usage Typical 10 Gig users are: High-performance computing (HPC) clusters Data Centers Scaled-up, consolidated servers Real-time video streaming on Web servers Workgroups involved in data-intensive, collaborative activities such as digital imaging and editing, simulation and modeling, and CAD/CAM Patient Archiving and Communications Systems - PACS 3

4 Topology and Cabling System Challenges - Obstacles to Achieving 10G 10GBASE-T PHY will rely heavily on the previously developed IEEE BASE-T and 1000BASE-T standard topology and technology. 10 Gigabit per second (Gbit/s) will operate similar to the 1000BASE-T with full duplex channels over 4 pair cabling, with each pair supporting 2.5 Gigabit per second simultaneously in both directions. The main obstacle in achieving this goal will be the design and construction of a suitable cabling system. While it is the role of IEEE 802.3an to develop electronics and active equipment standards, it is the TIA (Telecommunications Industry Association) role to develop standards for cabling systems. Typically, IEEE members prefer to use an existing cabling standard, but in this case, the highest category of cables (CAT6) was not capable of supporting the full distance required by TIA (100 meters). Before a suitable cable system could be produced, a number of challenges had to be overcome. The first is Power Sum Alien NEXT (PSANEXT). PSANEXT refers to alien crosstalk generated by coupling from adjacent Category 6 cabling channels within the vicinity. The second is the extended frequency required by 10gig of up to 500 MHz, double the frequency required by Category 6. Distance limitations are due to alien crosstalk, and based on link/channel modeling, the TIA TR42.7 Cabling Task Group decided the following at its latest draft: 10 gig should run over Category 6 cabling up to 37 meters without mitigation 10 gig should run over Category 6 cabling between meters with some mitigation 10 gig running over Category 6 channels of 55 meters and above will require mitigation TIA cabling task group developed methods and procedures to address ANEXT mitigation on Category 6 UTP cabling. Category 6 Shielded and Class F (Category 7) cabling does not require any mitigation due to the shielding available in these cables that will protect from outside interference including that from adjacent cables. Cabling Standards Role New TIA Standards Per the request of IEEE 802.3an, the TIA TR42.7 Cabling Task Group has been working on two projects to meet the 802.3an objectives. They are as follows: TSB-155: Develop a Technical System Bulletin (TSB) to describe additional guidelines for installed Category 6 cabling to support the proposed 10GBASE-T standard. These guidelines are intended to provide additional information on the extended frequency transmission performance of Category 6 cabling from 250MHz up to 500MHz. This bulletin (which was approved for release in December 06) also characterizes Alien Crosstalk (ANEXT) and provides additional guidelines for field test methods and ANEXT mitigation. The recommendations are intended to assess the installed Category 6 cabling and determine if 10GBASE-T is feasible. 568-B.2-10: Addendum10 of 568-B.2 specifies the development of cabling, component specifications, and test procedures to support the operation of IEEE 802.3an 10 Gigabit Ethernet (10GBASE-T) over 100 meters of an Augmented Category 6 (CAT6A) cabling. The frequency characterization will be extended from 250MHz to 500MHz for increased available bandwidth. Estimated completion time is June

5 Cabling System Progress Design Changes, Testing for ANEXT Manufacturers have accepted the 10gig challenge and most have developed a new cabling system that will meet CAT6A requirements. These new solutions have necessitated sweeping changes in cabling system design, with the most apparent changes being made to the horizontal and patch cables. To overcome alien crosstalk (ANEXT), the cables will be larger, and may have various internal separators, or in some cases, an alternative construction design. Another challenge is testing for ANEXT, as testing a cable bundle is more complex than testing a singular cable as we do today with CAT6 and 5e links. TIA has devised a referee ANEXT test method that includes seven cables in a form of six-around-one to simulate a typical bundle (see Figure 1). Figure 1 The necessity of testing for ANEXT adds time to the already time-consuming process of field-testing. The process is streamlined somewhat when random bundles are selected for testing and the end user accepts the method of sample selection, but it remains a time, resource, and labor intensive process. Reputable manufacturers of 10gig solutions do their best to support end users, and perform the necessary ANEXT lab testing to verify compliance prior to shipment. This saves the end user valuable time and resources. The biggest change to the connector has been to its circuit board, where pins have been separated as much as possible. A few creative manufacturers have tried to mittigate ANEXT by creating a separation on the outside of the connector body. 10gig patch cord designs are similar to the horizontal cable design, except that we notice some manufacturers adding a floating shield to help mitigate alien cross talk. The greatest challenge in designing a 10gig patch cord is the size of the patch cable, as it is still required to fit in the standard plug. 5

6 Summary 10 Gigabit Ethernet is a dominant technology in the backbone for high intensive bandwidth networks. Gigabit Ethernet will be the dominant technology to workstations until low latency and high bandwidth applications that require 10 Gigabit Ethernet are deployed. Existing Category 6 UTP installations could possibly support 10 Gigabit Ethernet, but only for short distances, and will most likely require mitigation as specified in TSB-155. To save on material costs, well-intentioned contractors or end users will often choose to install CAT6 cabling in place of CAT6A cabling. Unfortunately, this practice often results in increased costs due to having to trouble shoot links, testing for Alien Crosstalk, etc. In order to get the system to pass, it may become necessary to switch many of the components to CAT6A. Therefore, Leviton recommends that end-users needing a 10Gig Solution should install a CAT6A cabling system. If CAT6 was previously installed (and a 10gig solution is required), then testing is a must, and following mitigation techniques for TSB-155 is crucial. 6

7 extreme 10G Leviton s 10G Solution Looking much like a typical connector, patch panel, and patch cord, the biggest changes to Leviton s 10G Solution are internal. The extreme 10G QuickPort connector (figure 2) features two important technologies. The Cone of Silence (COS) was developed to resist ANEXT between neighboring connectors. The second is Retention Force Technology (RFT) which helps ensure error free performance over the life of the system by reinforcing tine contacts, even when 4- or 6-pin plugs have been used. Leviton 10G Patch Panels are available in Standard, Angled, Recessed Angled configurations supporting 24- or 48-ports. When rack or closet space is tight, a High-Density 1RU/48-port panel is also available. All Leviton 10G Patch Panels are preloaded with extreme 10G connectors. Leviton extreme 10G Patch Cords are constructed using a flexible wire to ensure both adequate life and long-term channel integrity. extreme 10G patch cords are available in seven TIA/EIA 606-A compatible colors and feature color matched cords and boots. Patch Cords are available in six standard lengths, as well as custom lengths. Figure 2 Leviton nd St. S.E. Bothell, WA USA Phone: (800) Fax: (425) Website: Leviton Canada 165 Hymus Blvd. Point-Claire, Quebec Canada H9R-1G2 Phone: (514) Fax: (514) International Customers Call Leviton Voice & Data International Sales Department Phone: (425) Fax: (425)

with Component Rating A Simple Perspective

with Component Rating A Simple Perspective Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America

More information

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks HIGHSPEED ETHERNET THE NEED FOR SPEED Jim Duran, Product Manager - Americas WHITE PAPER Molex Premise Networks EXECUTIVE SUMMARY Over the years structured cabling systems have evolved significantly. This

More information

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd

More information

10 Gigabit Ethernet over copper: Unshielded, unprotected?

10 Gigabit Ethernet over copper: Unshielded, unprotected? Technical Article 10 Gigabit Ethernet over copper: Unshielded, unprotected? Copyright 2005 Reichle & De-Massari AG (R&M). All rights reserved. Transmission and reproduction of this publication or parts

More information

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission

More information

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Introduction When network managers decide on a cabling system,

More information

Gigabit Ethernet on Copper Cabling Infrastructures

Gigabit Ethernet on Copper Cabling Infrastructures Gigabit Ethernet on Copper Cabling Infrastructures Overview of Gigabit Ethernet (1000Base-T) Ethernet was developed by the Xerox Corporation in the early 1970 s and has emerged as the dominant networking

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

Implementing Fast Ethernet

Implementing Fast Ethernet Implementing Fast Ethernet R The Next Generation of Ethernet Fast Ethernet (also known as IEEE 802.3u or 100BASE-T) is quickly becoming the successor to Ethernet as the network topology of choice. Fast

More information

How to Choose the Right Cable Category

How to Choose the Right Cable Category How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category

More information

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Paul Vanderlaan Product Development Engineer Belden Presented at BICSI January 20, 1999 Introduction New Parameters involving

More information

Data Communications Competence Center

Data Communications Competence Center Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation

More information

AMP NETCONNECT Data Center Cabling Solutions

AMP NETCONNECT Data Center Cabling Solutions AMP NETCONNECT Data Center Cabling Solutions Modern business and administrative environments require today more and more sophisticated IT services, what leads to an increasing demand for data provision

More information

Arista and Leviton Technology in the Data Center

Arista and Leviton Technology in the Data Center Visit: www.leviton.com/aristanetworks Arista and Leviton Technology in the Data Center Customer Support: 1-408-547-5502 1-866-476-0000 Product Inquiries: 1-408-547-5501 1-866-497-0000 General Inquiries:

More information

100BASE-SX Fast Ethernet:

100BASE-SX Fast Ethernet: 100BASE-SX Fast Ethernet: A Cost Effective Migration Path for Fiber in the Horizontal Prepared by the Fiber Optics LAN Section of the Telecommunications Industry Association February 2000 2000 TIA Fiber

More information

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD Data Center Standards Roundup BICSI, TIA, CENELEC, ISO Steve Kepekci, RCDD Introduction Regardless of business activity or size, all information technology (IT) groups have similar needs Provide secure,

More information

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com DATA CENTER NETWORK INFRASTRUCTURE Cable and Connectivity for the Most Demanding Networks Customer-focused, technology-driven, quality-assured for an unparalleled RETURN ON infrastructure investment DATA

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks By Galen Udell Belden CDT Networking 2006 Category 6 vs Category 5e Cabling Systems and Implications

More information

Advantages of 4 th Generation CAT 6A UTP Cables. Antonio Cartagena Business Development - Caribbean Leviton Network Solutions

Advantages of 4 th Generation CAT 6A UTP Cables. Antonio Cartagena Business Development - Caribbean Leviton Network Solutions Advantages of 4 th Generation CAT 6A UTP Cables Antonio Cartagena Business Development - Caribbean Leviton Network Solutions Internet Protocol Bandwidth and Forecast: 2011-2016 Global IP traffic will increase

More information

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram www.psiberdata.com Agenda Market Market Trend and Trend business and and business case for case higher

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

Copper for Beyond 10GBASE-T. David Zambrano

Copper for Beyond 10GBASE-T. David Zambrano Copper for Beyond 10GBASE-T David Zambrano Agenda Market Drivers Standards Cabling and Ethernet Field Test Considerations Agenda Market Drivers Standards Cabling and Ethernet Field Test Considerations

More information

Total Solutions Verification

Total Solutions Verification Total Solutions Verification 3rd Party Electrical Performance Testing Author: Tom Boucino Applications Engineer Uniprise Solutions CommScope has always designed cables with connectivity in mind. Our engineers

More information

CommScope Intelligent Building Infrastructure Solutions (IBIS)

CommScope Intelligent Building Infrastructure Solutions (IBIS) SYSTIMAX Solutions CommScope Intelligent Building Infrastructure Solutions (IBIS) Questions & Answers Q. What is an Intelligent Building? A. An intelligent building can be defined as one which provides

More information

Cable Sharing in Commercial Building Environments

Cable Sharing in Commercial Building Environments Cable Sharing in Commercial Building Environments Reducing Cost, Simplifying Cable Management, and Converging Applications onto Twisted-Pair Media Cable sharing describes the practice of running more than

More information

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error

More information

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres White Paper Nexans Cabling Solutions September 2006 Executive Summary Planning for the unknown is always a difficult

More information

Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek

Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek Supporters Mike Grimwood Broadcom Will Bliss Broadcom Dariush Dabiri APM Dan

More information

Data Center Architecture with Panduit, Intel, and Cisco

Data Center Architecture with Panduit, Intel, and Cisco Data Center Architecture with Panduit, Intel, and Cisco 0GBASE-T Application Note Integrating Panduit Category 6A Interconnects with the Cisco Nexus TM and Intel Ethernet Server Adapter X0-T 0 PANDUIT

More information

16-Port and 24-Port 10/100 Switches

16-Port and 24-Port 10/100 Switches 16-Port and 24-Port 10/100 Switches Use this guide to install the following products: SR216 SR224 16-Port 10/100 Switch 24-Port 10/100 Switch User Guide COPYRIGHT & TRADEMARKS Specifications are subject

More information

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network WP4270 Issued: June 2011 Authors: Carl Roberts and Merrion Edwards Introduction

More information

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet Today s network managers know that modern demands on a network by its users can shrink bandwidth dramatically. Faster computers,

More information

White Paper. Influence of Cabling Systems on the Availability of Data Centers

White Paper. Influence of Cabling Systems on the Availability of Data Centers White Paper Influence of Cabling Systems on the Availability of Data Centers Influence of Cabling Systems on the Availability of Data Centers TABLE OF CONTENTS 1. Economic Success Factors for Data Centers...3

More information

Copper Closet. Copper Closet

Copper Closet. Copper Closet Copper Closet Copper Closet Copper Closet Contents: CC-2 CC-5 CC-8 CC-12 CC-13 CC-14 CC-17 Limited Axcess Category 6a Solutions Patch Panels Cable Assemblies Category 6 Patch Cords 110 Wiring Products

More information

Zone Distribution in the Data Center

Zone Distribution in the Data Center Zone Distribution in the Data Center By Jennifer Cline, RCDD As data centers face the continued need to expand and grow, the fundamental concerns and needs remain constant. Key concerns of the data cabling

More information

Power over Ethernet (PoE)

Power over Ethernet (PoE) Power over Ethernet (PoE) Power over Ethernet (PoE) sends direct current (DC) voltage and computer data over the same Ethernet cable, enabling a device to receive DC power and computer data simultaneously.

More information

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers Jonathan Jew jew@j-and-m.com J&M Consultants, Inc Co-chair TIA TR-42.1.1 data center working group Co-chair BICSI data centers standards

More information

Accelerating Light. Copper Cabling Solutions. Category 6A

Accelerating Light. Copper Cabling Solutions. Category 6A Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity

More information

10GBASE T for Broad 10_Gigabit Adoption in the Data Center

10GBASE T for Broad 10_Gigabit Adoption in the Data Center 10GBASE T for Broad 10_Gigabit Adoption in the Data Center Contributors Carl G. Hansen, Intel Carrie Higbie, Siemon Yinglin (Frank) Yang, Commscope, Inc 1 Table of Contents 10Gigabit Ethernet: Drivers

More information

Infrastructure Trends 40G / 100G Migration. Maurice F. Zetena III Vice President Leviton Technology Data Center Group Leviton Network Solutions

Infrastructure Trends 40G / 100G Migration. Maurice F. Zetena III Vice President Leviton Technology Data Center Group Leviton Network Solutions Data Center: Technology Drivers Infrastructure Trends 40G / 100G Migration Maurice F. Zetena III Vice President Leviton Technology Data Center Group Leviton Network Solutions Technology Drivers Convergence

More information

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Needs in the Data Center With the continued requirement for expansion and growth in the data center, infrastructures must provide

More information

Chapter 4 Connecting to the Internet through an ISP

Chapter 4 Connecting to the Internet through an ISP Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No

More information

VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE

VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE VIDEO SURVEILLANCE OVER UTP WHITE PAPER INTRODUCING VIPER VIDEO SURVEILLANCE 1 C O N T E N T S Security Systems can be integrated into any IT Network The Network Manager s New Responsibility The Problem

More information

Power over Ethernet with Panduit Copper Cabling

Power over Ethernet with Panduit Copper Cabling Power over Ethernet with Panduit Copper Cabling Introduction Power over Ethernet (PoE) is a common way to reduce installation costs and time by allowing power and data onto a single twisted-pair cable.

More information

GigaSPEED X10D Solution How

GigaSPEED X10D Solution How SYSTIMAX Solutions GigaSPEED X10D Solution How White Paper June 2009 www.commscope.com Contents Modal Decomposition Modeling and the Revolutionary 1 SYSTIMAX GigaSPEED X10D Performance MDM An Introduction

More information

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8 Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,

More information

Nexus Technology Review -- Exhibit A

Nexus Technology Review -- Exhibit A Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.

More information

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch Manual TABLE OF CONTENTS About This Guide... 1 PURPOSE...1 TERMS/USAGE...1 OVERVIEW OF THIS USER S GUIDE...1 Introduction... 2 FAST ETHERNET TECHNOLOGY...2

More information

NETWORKING GUIDE. designed to be better.

NETWORKING GUIDE. designed to be better. NETWORKING GUIDE designed to be better. 2 The home network is more critical than ever before. ARE YOU CAPITALIZING ON THE OPPORTUNITY? Every home network is different, just like the needs of your customers.

More information

How to cable 802.11n Wireless Access Points

How to cable 802.11n Wireless Access Points How to cable 802.11n Wireless Access Points The 802.11n standard is an important advance in wireless Local Area Networks (LANs). In 2007, residential consumers began installing 802.11n products and in

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

1000BASE-T: Gigabit Ethernet. over Category. 5 copper. cabling. Acronyms and abbreviations

1000BASE-T: Gigabit Ethernet. over Category. 5 copper. cabling. Acronyms and abbreviations 1000BASE-T: Gigabit Ethernet over Category 5 copper cabling By Christopher T. Di Minico Acronyms and abbreviations ANSI American National Standards Institute BER Bit error rate DSL Digital subscriber line

More information

The High Cost of a Low-Cost Cable Certification Tester

The High Cost of a Low-Cost Cable Certification Tester The High Cost of a Low-Cost Cable Certification Tester How much does it cost? That is typically the first question a cabling contractor or network owner asks when considering a new certification tester

More information

Auspex Support for Cisco Fast EtherChannel TM

Auspex Support for Cisco Fast EtherChannel TM Auspex Support for Cisco Fast EtherChannel TM Technical Report 21 Version 1.0 March 1998 Document 300-TC049, V1.0, 980310 Auspex Systems, Inc. 2300 Central Expressway Santa Clara, California 95050-2516

More information

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

Top of Rack: An Analysis of a Cabling Architecture in the Data Center SYSTIMAX Solutions Top of Rack: An Analysis of a Cabling Architecture in the Data Center White paper Matthew Baldassano, Data Center Business Unit CommScope, Inc, June 2010 www.commscope.com Contents I.

More information

10GBASE-T for Broad 10 Gigabit Adoption in the Data Center

10GBASE-T for Broad 10 Gigabit Adoption in the Data Center WHITE PAPER 10GBASE-T Ethernet Network Connectivity 10GBASE-T for Broad 10 Gigabit Adoption in the Data Center The increasing use of virtualization and unified networking places extreme I/O demands on

More information

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices Robert Reid (Panduit) Frank Yang (CommScope, Inc) 1 The Presenters Robert Reid Sr. Product Development Manager at Panduit Frank Yang Marketing

More information

in undergraduate, graduate, professional

in undergraduate, graduate, professional UNIVERSITY OF MISSOURI Kansas City UMKC About The University The University of Missouri-Kansas City is strategically located in the second largest population center of the state. It has both the opportunity

More information

10GBASE-T for Broad 10 Gigabit Adoption in the Data Center

10GBASE-T for Broad 10 Gigabit Adoption in the Data Center Third-party information brought to you courtesy of Dell. WHITE PAPER 10GBASE-T Ethernet Network Connectivity 10GBASE-T for Broad 10 Gigabit Adoption in the Data Center The increasing use of virtualization

More information

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year

More information

Belden. Copper Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN Copper Systems

Belden. Copper Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN Copper Systems Belden Copper Catalog One Enterprise. One Infrastructure. One Partner. Belden IBDN Copper Systems Belden has the end-to-end copper cabling system to meet your current networking challenges while providing

More information

T1 Networking Made Easy

T1 Networking Made Easy T1 Networking Made Easy 1 THE T1 CARRIER 3 WHAT DOES A T1 LOOK LIKE? 3 T1 BANDWIDTH 3 T1 PHYSICAL CHARACTERISTICS 4 T1 FRAMING 5 LINE CODE 6 T1 NETWORKING 6 TELCOS 6 PSTN ACCESS WITH A T1 8 SUMMARY OF

More information

A Comparison of Total Costs of Ownership of 10 Gigabit Network Deployments in the Data Center

A Comparison of Total Costs of Ownership of 10 Gigabit Network Deployments in the Data Center A Comparison of Total Costs of Ownership of 10 Gigabit Network Deployments in the Data Center White Paper November 2009 www.commscope.com Contents Introduction 2 Objectives 2 Executive Summary 3 Background

More information

Next Generation Data Centre ICT Infrastructures. Harry Forbes CTO NCS

Next Generation Data Centre ICT Infrastructures. Harry Forbes CTO NCS Next Generation Data Centre ICT Infrastructures Harry Forbes CTO NCS White Paper Nexans Cabling Solutions July 2010 Next Generation Data Centre ICT Infrastructures Harry Forbes CTO NCS Executive Summary

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note Plug & Play Gigabit Ethernet Media Conversion Module Application Note The Plug & Play Universal Systems Media Converter Module offers the best of both worlds easy fiber optic scalability and future proofing

More information

Leviton Network Solutions Certified Contractors

Leviton Network Solutions Certified Contractors Leviton Network Solutions Certified Contractors Hiring a Leviton Certified Contractor is your key to a reliable, worry-free network installation backed by our industry-leading warranty. Why Choose a Leviton

More information

Optimizing Infrastructure Support For Storage Area Networks

Optimizing Infrastructure Support For Storage Area Networks Optimizing Infrastructure Support For Storage Area Networks December 2008 Optimizing infrastructure support for Storage Area Networks Mission critical IT systems increasingly rely on the ability to handle

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

32-bit PCI 10/100/1000Mbps Gigabit Ethernet Card. User s Guide. FCC Warning. CE Mark Warning. VCCI Warning

32-bit PCI 10/100/1000Mbps Gigabit Ethernet Card. User s Guide. FCC Warning. CE Mark Warning. VCCI Warning FCC Warning 32-bit PCI 10/100/1000Mbps Gigabit Ethernet Card User s Guide This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15 of the

More information

WHITE PAPER December, 2001

WHITE PAPER December, 2001 Is Superior Essex Outside Plant Copper Cable Rated Category 3? The applicability of the Category 3 specification to outside plant cables is sometimes misunderstood. This white paper examines that issue,

More information

40GBASE-T Advantages and Use Cases

40GBASE-T Advantages and Use Cases 40GBASE-T Advantages and Use Cases Andy Jimenez Anixter Inc. 40GBASE-T Task Force San Diego, California USA July, 2014 1 Contributors Masood Shariff Frank Straka - Commscope - Panduit 2 Supporters Wayne

More information

Data Center Design for 40/100G

Data Center Design for 40/100G Data Center Design for 40/100G With the continued requirement for expansion and scalability in the data center, infrastructures must provide reliability, manageability and flexibility. Deployment of an

More information

Broadband 101: Installation and Testing

Broadband 101: Installation and Testing Broadband 101: Installation and Testing Fanny Mlinarsky Introduction Today the Internet is an information superhighway with bottlenecks at every exit. These congested exits call for the deployment of broadband

More information

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village Brno, Marec 2014 Physical Infrastructure trends and certification requirements for Datacenters Ing. Peter Potrok PROFiber Networking s.r.o. Psiber s Global Village London Munich San Diego Boston Paris

More information

DeSoto County Chooses Siemon & Cyber Technology Security for 21st Century School District

DeSoto County Chooses Siemon & Cyber Technology Security for 21st Century School District DeSoto County Chooses Siemon & Cyber Technology Security for 21st Century School District Lendon Balch - DeSoto's Director of Technology Delivery, Milton Kuykendall - Superintendent of Education for the

More information

IP TELEPHONY A REVOLUTION FOR STRUCTURED CABLING SYSTEMS

IP TELEPHONY A REVOLUTION FOR STRUCTURED CABLING SYSTEMS IP TELEPHONY A REVOLUTION FOR STRUCTURED CABLING SYSTEMS by André Mouton, Product Line Manager and Julie Roy, IBDN Standards, Systems and Applications Manager NORDX/CDT inc. TABLE OF CONTENT INTRODUCTION...

More information

ethernet alliance 10GBASE-T: 10 Gigabit Ethernet over Twisted-pair Copper Version 1.0 August 2007

ethernet alliance 10GBASE-T: 10 Gigabit Ethernet over Twisted-pair Copper Version 1.0 August 2007 10GBASE-T: 10 Gigabit Ethernet over Twisted-pair Copper Version 1.0 August 2007 Authors 1 : Hugh Barrass, Cisco Michael Bennett, Lawrence Berkeley National Laboratory Brad Booth, Applied Micro Circuits

More information

10G and Beyond in the Data Center with OM3 Fiber

10G and Beyond in the Data Center with OM3 Fiber 10G and Beyond in the Data Center with OM3 Fiber Doug Coleman, Manager Technology and Standards doug.coleman@corning.com Overview Optical Trends in Data Center Networks The time is NOW for 10G optical

More information

palm Switch 500 5 Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

palm Switch 500 5 Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide palm Switch 500 5 Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide Rev. 1.0 June, 2003 User Guide 1. Introduction Welcome to the World of Mini-Networking. In the modern business society, communication

More information

Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center

Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center May 2013 Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center Executive Summary There is no single end-all cabling configuration for every data center, and CIOs, data center

More information

Whitepaper. 10 Things to Know Before Deploying 10 Gigabit Ethernet

Whitepaper. 10 Things to Know Before Deploying 10 Gigabit Ethernet Whitepaper 10 Things to Know Before Deploying 10 Gigabit Ethernet Table of Contents Introduction... 3 10 Gigabit Ethernet and The Server Edge: Better Efficiency... 3 SAN versus Fibre Channel: Simpler and

More information

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission

More information

www.commscope.com Data Center Topology Guide

www.commscope.com Data Center Topology Guide www.commscope.com Data Center Topology Guide Data Center Areas 1 Network Operations Center (NOC) The network operations center or NOC is the location where control of all data center networking, server

More information

HDMI / Video Wall over IP Transmitter with PoE

HDMI / Video Wall over IP Transmitter with PoE / Wall over IP Transmitter with Key Features Network 1080P ultra high quality video transmitter Assigns video sources to any monitor of the video wall Up to 8 x 8 Screen Array supported Extends high definition

More information

Data Center Design Considerations

Data Center Design Considerations Data Center Design Considerations Chris DiMinico MC Communications cdiminico@ieee.org Contributors: Jonathan Jew, President, J&M Consultants (Telecommunication Engineering Firm) Co-chair TR42.1.1, Data

More information

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration Bill Charuk, SR Product Manager, Data Center Solutions Introduction With the advent of data centers in communication infrastructure, various

More information

Your Network. Our Connection. 10 Gigabit Ethernet

Your Network. Our Connection. 10 Gigabit Ethernet Your Network. Our Connection. 10 Gigabit Ethernet t Agenda Why 10G? Applicable 10GbE Standards Distance Restrictions Copper Fiber Fiber Repeaters 3R s Fiber Module Types Form Factors of 10G modules Future

More information

Upgrading Path to High Speed Fiber Optic Networks

Upgrading Path to High Speed Fiber Optic Networks SYSTIMAX Solutions Upgrading Path to High Speed Fiber Optic Networks White Paper April, 2008 www.commscope.com Contents Connectivity Method A 4 Upgrading Method A to Parallel Optics 4 Connectivity Method

More information

RF Video Distribution System. Why Z-Band is The Right Choice for Quality Video

RF Video Distribution System. Why Z-Band is The Right Choice for Quality Video RF Video Distribution System Why Z-Band is The Right Choice for Quality Video Requirements for Quality RF Video Correct Signal & Noise Levels from Source/s Correct Signal & Noise Levels from Backbone Cabling

More information

724-746-5500 blackbox.com

724-746-5500 blackbox.com $27.95 Networking Standards Cabling Structured Cabling System Installation & Testing 724-746-5500 blackbox.com Other Standards What is structured cabling? A structured cabling system is the wiring network

More information

Data and Voice Network Infrastructure

Data and Voice Network Infrastructure Data and Voice Network Infrastructure Denis Levesque Mike Milne Sponsored By Data and Voice Network Infrastructure Page 1 Copyright APPA 2015 Published by APPA: APPA is the association of choice serving

More information

Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching

Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching 502 Buffalo Rd., Ft. Pierre, SD 57532 (605) 224-1111 or (800) 747-6427 www.windcircle.net sales@windcircle.net Computers

More information

SummitStack in the Data Center

SummitStack in the Data Center SummitStack in the Data Center Abstract: This white paper describes the challenges in the virtualized server environment and the solution that Extreme Networks offers a highly virtualized, centrally manageable

More information

Gigabit Transmission

Gigabit Transmission Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom

More information

Communication Setup Application Note

Communication Setup Application Note Communication Setup Application Note This Application Note describes how to install and set up communication between the inverter and the SolarEdge Monitoring Server. This document contains the following

More information

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and

More information

Belden Copper Catalog

Belden Copper Catalog Belden Copper Catalog Faster. Easier. Better. Belden IBDN Copper Systems Belden has the end-to-end copper cabling system to meet your current networking challenges while providing the bandwidth and scalability

More information

White Paper Solarflare High-Performance Computing (HPC) Applications

White Paper Solarflare High-Performance Computing (HPC) Applications Solarflare High-Performance Computing (HPC) Applications 10G Ethernet: Now Ready for Low-Latency HPC Applications Solarflare extends the benefits of its low-latency, high-bandwidth 10GbE server adapters

More information