ISO 9001 SERIE NERO OIL-LESS ROTARY VANE VACCUM PUMPS OIL-LESS ROTARY VANE COMPRESORS DRY RUNNING AIRCOOLED
|
|
- Katrina Mathews
- 7 years ago
- Views:
Transcription
1 ISO 900 SERIE NERO OIL-LESS ROTARY VANE VACCUM PUMPS OIL-LESS ROTARY VANE COMPRESORS DRY RUNNING AIRCOOLED
2 The Rotary Vane Principle Rotary vane vacuum pump working principle A rotor () positioned eccentrically in the pump cylindrical housing (), free moving vanes (4) are inserted into numerous rotor slots (3), when the rotor turns, the centrifugal force throws the vanes against the cylindrical wall, and creating chamber between the rotor and cylinder, as the rotor continues to turn, the chamber volume between blades keeps changing due to the rotor positioned eccentrically, from inlet (5) to outlet (6) port, the chamber volume will becomes bigger and then smaller, when chamber volume becomes bigger, vacuum produced result from the rotation of vanes, thus air enters the chamber from the inlet port, when the chamber volume becomes smaller, due to air compressed, pressure produced at the outlet port. vacuum pumps are manufactured in accordance to: EN 0- EN 0- / Compressors and Vacuum pumps EN ISO 00- EN ISO 00- EN 94 / Safety of machinery EN / Rotating electrical machines EN / Electrical equipment of machines EN EN EN EN / Electromagnetic Compatibility
3 Model NV for vacuum applications down to an ultimate pressure of 0/50 hpa. Model ND for max. overpressure duties up to 000 hpa (000 hpa abs.) ND and NV rotary vane vacuum pumps work absolutely oil free. Ambient operating environment : - ambient temperature : 0 ~ +40 C - air temperature at the inlet : -5 C ~ +40 C - altitude of above sea level : 800 M (max.) - relative humidity : 80% (max.) Storage conditions : dry dust-free low-vibration (<.8 mm/s) ambient temp. <40 C (04 F) Allowable voltage variance shall be within 5% of rated voltage, and frequency variance shall be within %. The motor of rotary vane vacuum pump - EN IP 54, 55 - Duty cycle S - CE, UL - Insulation class F (55 C) - Reference Atmosphere: 000mbar, +0 C - Allowable tolerance 5% model Capacity Max. m 3 /h Ultimate pressure Max. mbar (abs.) Overpressure Max. bar Motor output Full load kw Voltage 3 ~ V Noise level at m db 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz NV ND Y Y NV ND Y Y NV ND Y Y NV ND Y Y Weight kg
4 Rotary vane vacuum pump Compressor 4E 3E 4E 34E...version ND only 4E...version NV / ND only Model ND has an overpressure valve which is Regulated at maximal pressure (motor full load). The calibration must not be changed. Model ND 05EC / 040EC has an cooler to reduce temperature of blast air. Shown NV / ND 05
5 Part no. Part name Qt. 0 Motor 0 Star-Tolerance ring 03 Rotor 04 Clamping disc 05 Spring washer 06 Hexagon socket head screw 0 Cylinder body Lock washer Cylinder body screw 3 Carbon vanes 7 4 Inlet plug 4E (version ND ) Outlet plug 5 (version ND none) Screw plug 0 Cylinder cover Cylinder cover screw 4 Gasket 3 Filter cartridge 3E (version ND ) Filter cartridge 4 Pressure spring 4E (version ND ) Pressure spring 30 Filter cover 3 (version ND ) Screw plug 3 Sealing ring 33 Filter cover screw 3 34 (version NV ) Silencer valve 34E (version ND ) Pressure relief valve 40 Radial fan 4 Plug 4E Edge protection 50 Base 5 Vibration absorber Sleeve Rubber element Washer Base screw Hood Rubber bushing Space tube Hexagon socket set screw Ring nut Washer Hexagon socket base screw Front hood Hexagon socket hood screw 4 4 Replacement of spare parts and therefore extraordinary maintenance of the vacuum pump must be carried out by the retailer s specialized and authorized personnel only. If any maintenance operations other than those expressly indicated in this handbook are carried out, the guarantee of vacuum pump will be immediately null and void and manufacturer shall be relieved of all and any responsibility with regard to accidents involving persons or things. Always order spare parts from your regular retailer remembering to indicate the vacuum pump model, the part name and the serial number.
6 NV Version for Vacuum Dimension Unit: mm Locking vacuum (or pressure) of vacuum pump shall higher than full loading vacuum (pressure), do not operate over loading (current) remarked on rating plate or rating label, to prevent motor damage, electric current over load relay, adjustable pressure relief or vacuum limitation valve shall be installed to protect motor. Optional accessories -Air filter to the integral inlet filter when heavy dust loads are being pumped. -Vacuum limitation valve to control inlet pressure when pump is used on vacuum duties (only NV version) -Pressure relief valve to control outlet pressure when pump is used on pressure duties (only ND version) - Non-return valve to protect system against ingress of air opposite pressure, should pump stop for any reason. With pipelines exceeding 5 meters length, the installation of non-return valves are recommended. When the vacuum pump is switched off while under vacuum, gas may flow back into inlet pipe. Install non-return valve or shut-off valve can to avoid this. model A B C D E F G H J K L M N O P R TS NV PF / NV PF / NV PF 3/4 NV PF 3/4 All rights reserved for technical specification changes without prior approval from any source outside Bacca, when considered necessary based on our research and development.
7 ND Version for Compressor Dimension Unit: mm Locking vacuum (or pressure) of vacuum pump shall higher than full loading vacuum (pressure), do not operate over loading (current) remarked on rating plate or rating label, to prevent motor damage, electric current over load relay, adjustable pressure relief or vacuum limitation valve shall be installed to protect motor. Optional accessories -Air filter to the integral inlet filter when heavy dust loads are being pumped. -Vacuum limitation valve to control inlet pressure when pump is used on vacuum duties (only NV version) -Pressure relief valve to control outlet pressure when pump is used on pressure duties (only ND version) - Non-return valve to protect system against ingress of air opposite pressure, should pump stop for any reason. With pipelines exceeding 5 meters length, the installation of non-return valves are recommended. When the vacuum pump is switched off while under vacuum, gas may flow back into inlet pipe. Install non-return valve or shut-off valve can to avoid this. model A B C D E F G H J K L M N O P R TS ND PF / ND PF / ND PF 3/4 ND PF 3/4 All rights reserved for technical specification changes without prior approval from any source outside Bacca, when considered necessary based on our research and development.
8 Pressure relief valve Vacuum limitation valve Non-return valve - Vacuum limitation valve to control inlet pressure when pump is used on vacuum duties (only NV version) - Pressure relief valve to control outlet pressure when pump is used on pressure duties (only ND version) - Non-return valve to protect system against ingress of air opposite pressure, should pump stop for any reason. With pipelines exceeding 5 meters length, the installation of non-return valves are recommended. When the vacuum pump is switched off while under vacuum, gas may flow back into inlet pipe. Install non-return valve or shut-off valve can to avoid this.
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More informationMEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
More informationRotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
More informationOperation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415
Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationINDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single
More informationREFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there
More informationCDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
More informationAtlas Copco Stationary air compressors
Atlas Copco Stationary air compressors Oil-free and oil lubricated piston compressor 2.2 - kw / 3-7.5 hp QUALITY COMPRESSORS DESIGNED SPECIFICALLY FOR THE SNOW MAKING INDUSTRY Atlas Copco's L-range of
More informationBuy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.
Karcher Model:K 520M /CDN ( 59559150 ) - Parts Section:1.0 PIECE PARTS Page 1 of 16 1 50690940 1 COVER 2 50319770 1 COVER / 1.069-937.0 2 50312410 1 COVER 4 40503340 1 CHASSIS 5 51052230 1 AXLE 6 53215050
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationBuy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.
Karcher Model: K 620-M * ( 59556440 ) - Parts Section:1.1 TOP PART Page 1 of 18 1 50346460 1 STRAP 2 63031250 6 SCREW 3 50670230 1 COVER 4 63031940 2 SELF-TAPPING SCREW 5 50309650 1 COVER 6 50635710 1
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
More informationDirect Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40
Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane
More informationROTARY SCREW COMPRESSOR. RMD 30-37 - 45-55 kw
ROTARY SCREW COMPRESSOR RMD - - - 55 kw EN The RMD Coaxial Rotary Compressor high reliability high performance low maintenance is the result of decades of experience in manufacturing design and construction
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationSpecifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.
Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical
More informationOperation manual and Spare parts list 1400 - EL PUMP. November
Operation manual and Spare parts list 1400 - EL PUMP 10 GB November 1 KIMADAN A/S KIMADAN A/S 2 Operational manual and spare parts list 1400 El-pump 15, 20, 25 HP 5 30 kw 6 1. Description.. 3 2. Installation
More informationMEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationVertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
More information3/2-way pneumatic cartridge solenoid valve
3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as
More informationFixed displacement vane pumps
Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationAFE424 SERVICE PARTS
This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
More informationPARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR
Ingersoll-Rand Company 800-B Beaty Street P. O. Box 1803 Davidson, NC 28036 1-800-AIR-SERV (1-800-247-7378) www.air.ingersoll-rand.com PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR Ingersoll-Rand
More informationFOR SALE: RECYCLING PLANT FOR. - Aluminum scrap - Light metals - WEEE - Mixed industrial waste BANO PREMAC 28-90 HYDRO. Single shaft shredder
FOR SALE: RECYCLING PLANT FOR - Aluminum scrap - Light metals - WEEE - Mixed industrial waste BANO PREMAC 28-90 HYDRO Single shaft shredder Stationary, weight 40 ton Table of content Sale of BANO PREMAC
More informationMDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
More informationOUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.
Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
More informationHighly flexible couplings
Construction and operation 8.03.00 Instructions for installation 8.03.00 Types of stress 8.04.00 Diagrams for static deformation of the coupling ring 8.05.00 Coupling size 8.07.00 Examples of combinations
More informationS GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
More information3/2-way Mini Solenoid Valve
3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationSWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
More informationONE STAGE LIGHT OIL AND KEROSENE BURNERS
ONE STAGE LIGHT OIL AND KEROSENE BURNERS RDB SERIES RDB-R 6,8 4,6 kw RDB-R 4, 46, kw RDB.-.R, 4, kw RDB.-.R,, kw RDB,6 68,7 kw RDB. 4,, kw RDB4,7, kw The Riello RDB series of one stage light oil and kerosene
More informationInstallation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
More informationSpare Parts List M96A.24SM/B M96A.28SM/B
*16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationOperating Instructions Parts List Manual Scissor Lift Pallet Truck
Operating Instructions Parts List Manual Scissor Lift Pallet Truck Note: Operator MUST read and understand this operating instructions before use this Hand Scissor Lift. Thank you for using this hand scissors
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationThis instruction is valid for all ACD pump models shown on page 2
Screw pumps ACD Maintenance and Service Instruction This instruction is valid for all ACD pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service intervals
More informationQPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationTable of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19
Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR
More informationAIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationPOSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
More informationCustom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.
LEAKVALVE: HIGHLIGHTS The core of this valve is a diaphragm in stainless steel 316L, gold plated. Robust, it cannot be damaged with any normal methods. The dead volume is kept as small as possible. There
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationInrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
More informationVolkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationOil / Air Cooling Units for mechanical engineering and mobile hydraulics
Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 viflow@viflow.fi www.viflow.fi
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationParts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!
Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
More informationSolenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationTechnical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
More informationRadial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
More informationSITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents
English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force
More informationOperation Manual. Diaphragm pumps 1-headed MPC 301 E 4000732 2008-08-19
Operation Manual Diaphragm pumps 1-headed Types MP 301 E MPC 301 E 4000732 2008-08-19 We are constantly working on the further development of all our product types. Reprinting or reproduction of this manual,
More informationMACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent
More informationPressure reducing valve, direct operated, Type ZDR 6 D
RE 26 57/2.3 Replaces:.2 Pressure reducing valve, direct operated, ype ZDR 6 D Nominal size 6 Series 4X aximum operating pressure 2 bar aximum flow 5 L/min K 4279/ ype ZDR 6 DP2 4X/ Y Overview of contents
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 3 HYDRAULIC AND PNEUMATIC MOTORS The material needed for outcome 2 is very extensive
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationNewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
More informationSpare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S
*1756202470* 17562.0247.0 REV3 06/09 2012 Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S Issue Table description Issue n. of pages Overall view 06/2009 1 C.h.
More informationCHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER
000000000!"!##%!"!# & ( ) * + *, ( (-#(. *, )*/.( 0 - % ) ++ )%++) ( ++1 CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER Page 1 / 30 TEQCO597C B. Charging levels and modes Page 4 / 30 C. Plugs /
More informationTECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System
TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured
More informationOil - kerosene burners
Installation, use and maintenance instructions Oil - kerosene burners One stage operation CODE MODEL TYPE 3747469 G0 474T5 90 (0) - 05/008 TECHNICAL FEATURES Thermal power output 95 3 kw 8 8 kg/h Fuel
More information2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7
Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationGROENEVELD AUTOMATIC GREASING SYSTEMS
GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991
More information1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationMOLECULAR DRAG PUMPS MDP SERIES
MOLECULAR DRAG PUMPS MDP SERIES MOLECULAR DRAG PUMPS MDP SERIES If you need: to replace a rotary vane pump with a dry pump for an application at 10-3 a turbopump that can operate up to 10 a pump that can
More informationThe Axial Flow Valve. Class 300/600. sales@elster-instromet.co.uk www.elster-instromet.com SERIES
The Axial Flow Valve SERIES Class 300/600 sales@elster-instromet.co.uk www.elster-instromet.com THE AXIAL FLOW VALVE - SERIES 300/600 A UNIQUE REGULATOR What is the Axial Flow Valve? The Axial Flow Valve
More informationMaintenance and Service Instruction
Screw pumps E4 Maintenance and Service Instruction E4 1 IMO AB This instruction is valid for all E4 pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationCoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
More informationWolflite Safety Handlamp H-251E
Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63
More informationAir Vantage 500 Kubota
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-625 P-625 RETURN TO MAIN INDEX PARTS LIST FOR Air Vantage 500 Kubota P-625-A
More informationCRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
More informationARB AIR LOCKER Air Operated Locking Differentials
CKMTA12 & CKMTA24 On-Board Air Compressor Kit, Maximum Performance Specs: ITEM # QTY DESCRIPTION PART # NOTES 01(a) 2 COMPRESSOR ASSEMBLY (12V) CKM01 1 Voltage 12 Volts (CKMTA12), 24 Volts (CKMTA24) 01(b)
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationTWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/41 106 kw GS20D 58/81 220 kw
TWO STAGE GAS BURNERS RIELLO 4 GSD SERIES 9/4 6 58/8 The Riello 4 GSD series of two stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 4
More informationValve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
More informationPortable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
More informationILLUSTRATED PARTS LIST XTREME ICE MAKER (1230 SERIES) MODEL NO.
XTREME ICE MAKER (0 SERIES) MODEL NO. 00 00 00 00 00 00 0 XTREME ICE MAKER (0 SERIES) FIGURE. GENERAL ASSEMBLY (AIR CONDENSER SHOWN) 00 Screw TC - HXWS 00000 Screw TC - HXWS 0 (Marine) 0000 Grommet Nut
More informationSUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2
SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.
More information