Air Conditioners. Technical Data RKS-J

Size: px
Start display at page:

Download "Air Conditioners. Technical Data RKS-J"

Transcription

1 Air Conditioners Technical Data P a i r a p p l i c a t i o n E E D E N RKS-J

2 Air Conditioners Technical Data P a i r a p p l i c a t i o n E E D E N RKS-J

3 TABLE OF CONTENTS RKS-J 1 Features Specifications Nominal Capacity And Nominal Input Technical Specifications Electrical Specifications Electrical data Electrical Data Capacity tables Cooling Capacity Tables Dimensional drawings Dimensional Drawings Centre of gravity Centre of Gravity Piping diagrams Piping Diagrams Wiring diagrams Wiring Diagrams - Single Phase Sound data Sound Pressure Spectrum - Cooling Operation range Operation Range Split - Sky Air Outdoor Unit 1

4 k i ni l p- rp ao t o J i dr - l ti pua 1 Features c S U S K PS OR Energy efficient units: up to class A energy labels Outdoor units for pair application Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode. Outdoor unit silent operation: "silent" button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood. Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency 2 Split - Sky Air Outdoor Unit

5 2 Specifications 2-1 Nominal Capacity And Nominal Input FCQ35C8VEB / RKS35J2V1B FCQ50C8VEB / RKS50J2V1B Cooling capacity Min. kw 1.4 (3) 0.9 (3) Btu/h 4,780 (3) 3,070 (3) kcal/h 1,200 (3) 770 (3) Nom. kw 3.40 (3) 5.0 (3) Btu/h 11,600 (3) 17,100 (3) kcal/h 2,920 (3) 4,300 (3) Max. kw 3.7 (3) 5.6 (3) Btu/h 12,600 (3) 19,100 (3) kcal/h 3,180 (3) 4,820 (3) Power input Cooling Nom. kw EER Annual energy consumption kwh Energy label Cooling A Piping connections Liquid OD mm 6.35 Gas OD mm Drain OD mm 32 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: return air temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB; equivalent refrigerant piping length 5m (horizontal) (4) Nominal heating capacities are based on: indoor temperature: 20ºCDB, outdoor temperature: 7ºCDB, 6ºCWB, equivalent refrigerant piping: 5m, level difference: 0m. (5) All data mentioned is preliminary information FTXS20J2V1B / RKS20J2V1B FTXS25J2V1B / RKS25J2V1B FTXS35J2V1B / RKS35J2V1B 2-1 Nominal Capacity And Nominal Input Cooling capacity Min. kw Btu/h 4,400 4,800 5,800 kcal/h 1,120 1,200 1,460 Nom. kw 2.0 (3) 2.5 (3) 3.5 (3) 4.2 (3) 5.0 (3) Btu/h 6,800 (3) 8,500 (3) 11,900 (3) 14,300 (3) 17,100 (3) kcal/h 1,720 (3) 2,150 (3) 3,010 (3) 3,010 (3) 4,300 (3) Max. kw Btu/h 9,600 10,900 13,600 17,100 18,100 kcal/h 2,410 2,750 3,440 4,300 4,560 Power input Cooling Min. kw Nom. kw Max. kw EER Annual energy consumption kwh Energy label Cooling A Piping connections Liquid OD mm 6.35 Gas OD mm Drain OD mm 18.0 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m FTXS42J2V1B / RKS42J2V1B FTXS50J2V1B / RKS50J2V1B Split - Sky Air Outdoor Unit 3

6 2 Specifications 2-1 Nominal Capacity And Nominal Input FBQ35C7VEB / RKS35J2V1B FBQ50C7VEB / RKS50J2V1B Cooling capacity Min. kw Btu/h 4,800 3,100 kcal/h 12, Nom. kw 3.40 (3) 5.0 (3) Btu/h 11,600 (3) 17,100 (3) kcal/h 2,920 (3) 4,300 (3) Max. kw Btu/h 12,600 19,100 kcal/h 3,180 4,820 Power input Cooling Min. kw Nom. kw Max. kw EER Annual energy consumption kwh Energy label Cooling A B Piping connections Liquid OD mm 6.35 Gas OD mm Drain OD mm 26 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 2-1 Nominal Capacity And Nominal Input FHQ35BVV1B / RKS35J2V1B FHQ50BVV1B / RKS50J2V1B Cooling capacity Min. kw Btu/h 4,800 5,800 kcal/h 1,200 1,460 Nom. kw 3.4 (3) 5.0 (3) Btu/h 11,600 (3) 17,100 (3) kcal/h 2,920 (3) 4,300 (3) Max. kw Btu/h 12,600 19,100 kcal/h 3,180 4,820 Power input Cooling Min. kw Nom. kw Max. kw EER Annual energy consumption kwh Energy label Cooling A D Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 4 Split - Sky Air Outdoor Unit

7 2 Specifications 2-1 Nominal Capacity And Nominal Input FDKS50C7VMB / RKS50J2V1B Cooling capacity Min. kw 1.7 (3) Btu/h 5,800 (3) kcal/h 1,460 (3) Nom. kw 5.0 (3) Btu/h 17,100 (3) kcal/h 4,300 (3) Max. kw 5.3 (3) Btu/h 18,100 (3) kcal/h 4,560 (3) Power input Cooling Min. kw Nom. kw Max. kw EER 3.03 Annual energy consumption kwh 825 Energy label Cooling B Piping connections Liquid OD mm 6.35 Gas OD mm 12.7 Drain OD mm 26 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. (5) All data mentioned is preliminary information 2-1 Nominal Capacity And Nominal Input FFQ25B8V1B / RKS25J2V1B FFQ35B8V1B / RKS35J2V1B FFQ50B8V1B / RKS50J2V1B Cooling capacity Min. kw Btu/h 4,400 4,750 3,050 kcal/h 1,110 1, Nom. kw 2.5 (3) 3.4 (3) 4.7 (3) Btu/h 8,500 (3) 11,600 (3) 16,050 (3) kcal/h 2,150 (3) 2,920 (3) 4,040 (3) Max. kw Btu/h 10,200 12,600 19,100 kcal/h 2,580 3,180 4,820 Power input Cooling Min. kw Nom. kw Max. kw EER Annual energy consumption kwh Energy label Cooling A B D Piping connections Liquid OD mm 6.35 Gas OD mm Drain OD mm 26 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information Split - Sky Air Outdoor Unit 5

8 2 Specifications 2-1 Nominal Capacity And Nominal Input FDKS25E7VMB / RKS25J2V1B FDKS35E7VMB / RKS35J2V1B Cooling capacity Min. kw 1.3 (3) 1.4 (3) Btu/h 4,400 (3) 4,800 (3) kcal/h 1,110 (3) 1,200 (3) Nom. kw 2.4 (3) 3.4 (3) Btu/h 8,150 (3) 11,600 (3) kcal/h 2,060 (3) 2,920 (3) Max. kw 3.0 (3) 3.8 (3) Btu/h 10,200 (3) 13,000 (3) kcal/h 2,580 (3) 3,260 (3) Power input Cooling Nom. kw EER Annual energy consumption kwh Energy label Cooling A B Piping connections Liquid OD mm 6.35 Gas OD mm 9.52 Drain OD mm 26 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 2-1 Nominal Capacity And Nominal Input FVXS25FV1B / RKS25J2V1B FVXS35FV1B / RKS35J2V1B FVXS50FV1B / RKS50J2V1B Cooling capacity Min. kw Btu/h 4,400 4,800 kcal/h 1,120 1,200 Nom. kw 2.5 (3) 3.5 (3) 5.0 (3) Btu/h 8,500 (3) 11,900 (3) 17,100 (3) kcal/h 2,150 (3) 3,010 (3) 4,300 (3) Max. kw Btu/h 10,200 13,000 19,100 kcal/h 2,580 3,270 4,820 Power input Cooling Min. kw Nom. kw Max. kw EER Annual energy consumption kwh Energy label Cooling A Piping connections Liquid OD mm 6.35 Gas OD mm Drain OD mm 20.0 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 6 Split - Sky Air Outdoor Unit

9 2 Specifications 2-1 Nominal Capacity And Nominal Input FLKS25BAVMB / RKS25J2V1B FLKS35BAVMB / RKS35J2V1B FLKS50BAVMB / RKS50J2V1B Cooling capacity Min. kw Btu/h 4,100 3,070 kcal/h 1, Nom. kw 2.5 (3) 3.5 (3) 4.9 (3) Btu/h 8,500 (3) 11,900 (3) 16,730 (3) kcal/h 2,150 (3) 3,010 (3) 4,210 (3) Max. kw Btu/h 10,200 13,000 18,090 kcal/h 2,580 3,270 4,560 Power input Cooling Min. kw Nom. kw Max. kw EER Annual energy consumption kwh Energy label Cooling A B C Piping connections Liquid OD mm 6.35 Gas OD mm Drain OD mm 18.0 Heat insulation Both liquid and gas pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) All data mentioned is preliminary information 2-2 Technical Specifications RKS20J2V1B RKS25J2V1B RKS35J2V1B RKS42J2V1B RKS50J2V1B Casing Colour Ivory white Dimensions Unit Height mm Width mm Depth mm Packed unit Height mm Width mm Depth mm Weight Unit kg Packed unit kg Heat exchanger Length mm Rows Quantity 1 2 Fin pitch mm Stages Quantity Tube type ø7 Hi-XA ø8 Hi-XA Fin Type Waffle louvered fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller fan Air flow rate Cooling High m³/min cfm 1,278 1,183 1,271 1,317 1,797 Super m³/min low cfm 1,155 1,063 1,080 1,727 Heating Super m³/min - low cfm - Fan motor Model D23H-28 D50R-28 KFD C Output W Speed Cooling High rpm Super low rpm Heating Super low rpm - Sound power level Cooling High dba Split - Sky Air Outdoor Unit 7

10 2 Specifications 2-2 Technical Specifications RKS20J2V1B RKS25J2V1B RKS35J2V1B RKS42J2V1B RKS50J2V1B Sound pressure level Cooling High dba Silent operation dba Compressor Model 1YC23AEXD 2YC36BXD Type Hermetically sealed swing compressor Output W 600 1,100 Operation range Cooling Ambien Min. ºCDB -10 t Max. ºCDB 46 Refrigerant Type R-410A Charge kg Refrigerant oil Type FVC50K Charged volume l Piping connections Liquid OD mm 6.35 Gas OD mm Drain Type Hole ID mm 15.9 Piping length OU - IU Max. m Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) Level difference IU - OU Max. m Electrical Specifications RKS20J2V1B RKS25J2V1B RKS35J2V1B RKS42J2V1B RKS50J2V1B Power supply Phase 1~ Frequency Hz 50 Voltage V Current Nominal running Cooling A 2.5 (1) 2.4 (2) (1) 2.8 (2) (1) 4.1 (2) (1) 5.7 (2) (1) 6.4 (2) 6.1 current (RLA) (3) (3) (3) (3) (3) Starting current Cooling A Wiring connections For power supply Quantity 3 For connection with Quantity 4 indoor Remark Earth wire included Notes (1) 220V (2) 240V 8 Split - Sky Air Outdoor Unit

11 3 Electrical data 3-1 Electrical Data FTKS20J2V1B + RKS20J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 2.1 FTXS20J2V1B RKS20J2V1B RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D055006D RKS25J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 2.6 FTXS25J2V1B RKS25J2V1B FVXS25FV1B RKS25J2V1B FFQ25B8V1B RKS25J2V1B FLKS25BAVMB RKS25J2V1B FDKS25E7VMB RKS25J2V1B RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D Split - Sky Air Outdoor Unit 9

12 3 Electrical data 3-1 Electrical Data RKS35J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 3.9 FTXS35J2V1B RKS35J2V1B FVXS35FV1B RKS35J2V1B FFQ35B8V1B RKS35J2V1B FHQ35BVV1B RKS35J2V1B FBQ35C7VEB RKS35J2V1B FLKS35BAVMB RKS35J2V1B FDKS35E7VMB RKS35J2V1B RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D FTXS42J2V1B + RKS42J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 5.6 FTXS42J2V1B RKS42J2V1B RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D059709B 10 Split - Sky Air Outdoor Unit

13 3 Electrical data 3-1 Electrical Data RKS50J2V1B Representative Unit Combination Power Supply Comp OFM IFM Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA 6.3 FTXS50J2V1B RKS50J2V1B FVXS50FV1B RKS50J2V1B RLA is based on the following conditions, Indoor temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D Split - Sky Air Outdoor Unit 11

14 4 Capacity tables 4-1 Cooling Capacity Tables FTXS20J2V1B + RKS20J2V1B COOLING 50Hz V AFR 9.4 BF 0.14 Indoor Outdoor temperature ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI D SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables (fi gures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. FTXS25J2V1B + RKS25J2V1B COOLING 50Hz V AFR 10.8 BF 0.16 Indoor Outdoor temperature ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI D SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables (fi gures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. 12 Split - Sky Air Outdoor Unit

15 4 Capacity tables 4-1 Cooling Capacity Tables FTXS35J2V1B + RKS35J2V1B COOLING 50Hz V AFR 11.4 BF 0.21 Indoor Outdoor temperature ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI D070669A SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables (figures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air flow rate (AFR) and Bypass factor (BF) are tabulated above table. FTXS42J2V1B + RKS42J2V1B COOLING 50Hz V AFR 11.3 BF 0.14 Indoor Outdoor temperature ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI D SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables (fi gures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. Split - Sky Air Outdoor Unit 13

16 4 Capacity tables 4-1 Cooling Capacity Tables FTXS50J2V1B + RKS50J2V1B COOLING 50Hz V AFR 11.6 BF 0.18 Indoor Outdoor temperature ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI D SYMBOLS AFR: Air fl ow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables (fi gures out of the tables should not be used for calculation). 4. About SHC which are not mentioned on the table: please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions: Corresponding refrigerant piping length: 5 m; Level difference: 0 m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. 14 Split - Sky Air Outdoor Unit

17 5 Dimensional drawings 5-1 Dimensional Drawings RKS20-42J2V1B Drain outlet (I.D Ø 15.9 hose for connection) 4-holes for anchor bolts (M8 or M10) Minimum space for air passage Wall height on air outlet side = less than 1200 Handle Brand name label Manufacture s label Liquid stop valve (Ø 6.4CuT) Outdoor air thermistor Wiring inlet Service port In case of removing stop valve cover Gas stop valve (Ø 9.5CuT) 3D055546C RKS50J2V1B Drain outlet (I.D. Ø 15.9 hose for connection) Minimum space for air passage Wall height on air outlet side = less than holes for anchor bolts (M8 or M10) Brand name label Name plate Wiring inlet In case of removing stop valve cover Terminal strip with earth terminal Outdoor air temperature thermistor Liquid stop valve (Ø 6.4CuT) Service port Gas stop valve (Ø 12.7CuT) 3D051657Q Split - Sky Air Outdoor Unit 15

18 6 Centre of gravity 6-1 Centre of Gravity RKS20-35J2V1B 4D056351R RKS42J2V1B 4D059009E 16 Split - Sky Air Outdoor Unit

19 6 Centre of gravity 6-1 Centre of Gravity Split - Sky Air Outdoor Unit 17

20 7 Piping diagrams 7-1 Piping Diagrams RKS20J2V1B 7.0 CuT Heat exchanger Outdoor temperature thermistor 9.5 CuT 7.0 CuT Heat exchanger thermistor 7.0 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve normally: off 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling 3D059588B RKS25-35J2V1B 7.0 CuT Heat exchanger Outdoor temperature thermistor 9.5 CuT 7.0 CuT Heat exchanger thermistor 4.8 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve normally: off 4.8 CuT 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling 3D059589D 18 Split - Sky Air Outdoor Unit

21 7 Piping diagrams 7-1 Piping Diagrams RKS42J2V1B Heat exchanger Outdoor temperature thermistor 12.7 CuT Heat exchanger thermistor 4.8 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve normally: off 4.8 CuT 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling 3D059591A RKS50J2V1B 12.7 CuT Heat exchanger thermistor Heat exchanger Outdoor air temperature thermistor 4.0 CuT 4.0 CuT 4.0 CuT 4.0 CuT Capillary tube 1 Capillary tube 2 Capillary tube 3 Capillary tube 4 Muffl er with fi lter 6.4 CuT 6.4 CuT Refrigerant fl ow Cooling Propeller fan 6.4 CuT 12.7 CuT 12.7 CuT Muffl er Discharge pipe thermistor Four way valve normally: off 12.7 CuT 12.7 CuT Muffl er 12.7 CuT Motor operated valve Muffl er with fi lter 6.4 CuT Liquid stop valve Field piping (6.4 CuT) 12.7 CuT Field piping Compressor Gas stop valve with service port (12.7 CuT) 3D051636Q Split - Sky Air Outdoor Unit 19

22 8 Wiring diagrams 8-1 Wiring Diagrams - Single Phase RKS20-35J2V1B FIELD WIRING indoor outdoor C5,C6,C119 : Capacitor DB1, DB2, DB3 : Diode Bridge FU1, FU2, FU3 : Fuse IPM1, IPM2 : Instelligent Power Module L : Live L1 : Coil L1R : Reactor M1C : Compressor Motor M1F : Fan motor MRCW, MR30, MRM10, MRM20 : Magnetic Relay N : Neutral Q1L : Overload Protector PCB1, PCB2, PCB3 : Printed Circuit Board S10, S11, S20, S40, S50, S70, S80, S90, S100, S110 HL3, HN3, X11A, X12A : Connector RKS42J2V1B R1T, R2T, R3T : Thermistor SA1 : Surge Arrester SW1 : Forced operation switch V1, V2, V3 : Varistor X1M : Terminal Strip Y1E : Electronic Expansion Valve Coil Y1R : Reversing Solenoide Valve Coil Z1C, Z2C, Z3C : Ferrite Core : Protective Earth In case of cooling only type (outdoor) (discharge) (condenser) 1. Refer to the nameplate for the power requirements. 2. Size: length 105 x width Refer to purchasing specifi cation AS(Y)303002, unless otherwise specifi ed. 4. This drawing was drawn on CAD system. 3D065704B indoor Power supply outdoor (outdoor) (discharge) (condenser) FIELD WIRING C74, C75,C94, C95 : Capacitor DB1, DB2, DB3 : Diode Bridge FU1, FU2, FU3 : Fuse IPM1 : Instelligent Power Module L : Live L1 : Coil L1R : Reactor M1C : Compressor Motor M1F : Fan motor MRCW, MRM10, MRM20, MR30 : Magnetic Relay N : Neutral PCB1 : Printed Circuit Board Q1L : Overload Protector R1T~R3T : Thermistor SA1 : Surge Arrester Q31 : IGBT V1, V3, V4 : Varistor X1M : Terminal Strip Y1E : Electronic Expansion Valve Coil Z1C, Z2C, Z3C, Z4C : Ferrite Core S20, S40, S70, S80, S90 X11A : Connector : Protective Earth BLK : Black BLU : Blue BRN : Brown GRN : Green ORG : Orange RED : Red WHT : White YLW : Yellow 1. Refer to purchasing specifi cation AS303002, unless otherwise specifi ed. 2. This drawing was drawn on CAD system. 3. The electric wiring diagram label is 3P D059615A 20 Split - Sky Air Outdoor Unit

23 8 Wiring diagrams 8-1 Wiring Diagrams - Single Phase RKS50J2V1B Power supply To indoor unit sheet metal indoor FIELD WIRING outdoor (outdoor) (discharge) (condenser) Z1C~Z5C X1M, X2M Y1E V2, V3, V5, V6, V11 SA2 FU1, FU2, FU3 AC1, AC2 U, V, W, X11A, X12A E1, E2 : Ferrite Core : Terminal Strip : Electronic Expansion Valve Coil : Varistor : Surge Arrester : Fuse HR1, HR2 : Connector MRM10, MRM20 MRC/W : Magnetic Relay R1T~R3T : Thermistor S2~S102 LED A L N SW1 SW4 M1C M1F L1R Q1L PM1 PCB1, 2 Steel metal : Connector : Pilot lamp : Live : Neutral : Forced operation on/off SW (SW1) : Localsetting SW (SW4) : Compressor motor : Fan motor : Reactor : Overload protector : Power module : Printed circuit board : Terminal strip fi xed plate 1. Refer to purchasing specification AS303002, unless otherwise specifi ed. 2. This drawing was drawn on CAD system. 3. The electric wiring diagram label is 3P D056145B Split - Sky Air Outdoor Unit 21

24 9 Sound data 9-1 Sound Pressure Spectrum - Cooling RKS20-25J2V1B RKS35J2V1B Octave band sound pressure level db (0dB = bar) Octave band sound pressure level db (0dB = bar) Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency (Hz) 4D059600B Octave band center frequency (Hz) 4D059594B 1 Over All (db): (B,G,N is already rectifi ed) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source: 220~240V 50Hz JIS standard 4 Operation noise differs with operation and ambient conditions. 5 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Hz Scale 220~240V (H) A 46 1 Over All (db): (B,G,N is already rectifi ed) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source: 220~240V 50Hz JIS standard 4 Operation noise differs with operation and ambient conditions. 5 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Hz Scale 220~240V (H) A 48 RKS42J2V1B RKS50J2V1B Octave band sound pressure level db (0dB = bar) Octave band sound pressure level db (0dB = bar) Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency (Hz) 4D059598A Octave band center frequency (Hz) 4D059739A 1 Over All (db): (B,G,N is already rectifi ed) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source: 220~240V 50Hz JIS standard 4 Operation noise differs with operation and ambient conditions. 5 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Hz Scale 220~240V (H) A 48 1 Over All (db): (B,G,N is already rectifi ed) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source: 220~240V 50Hz JIS standard 4 Operation noise differs with operation and ambient conditions. 5 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Hz Scale 220~240V (H) A Split - Sky Air Outdoor Unit

25 10 Operation range 10-1 Operation Range RKS20-50J2V1B Outdoor temperature ( cdb) Continuous operation Pull-down period 1. The graph is based on the following conditions. Equivalent piping length 7.5 m Level difference 0 m Air fl ow rate High Indoor temperature ( cwb) 4D029297W Split - Sky Air Outdoor Unit 23

26 Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Multi units are Eurovent certified for combinations up to 2 indoor units The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium BE RPR Oostende EEDEN CD 01/11 Copyright Daikin The present publication supersedes EEDEN Prepared in Belgium by Lannoo ( a company whose concern for the environment is set in the EMAS and ISO systems. Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV

Air Conditioners. Technical Data. Wall Mounted Unit. www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV Air Conditioners Technical Data Wall Mounted Unit www.daikin.eu RX-JV/GV TABLE OF CONTENTS RX-JV/GV 1 Features.............................................................

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data C e i l i n g s u s p e n d e d u n i t E E D E N 2-0 0 FHQ-B8 Indoor Unit Ceiling suspended unit FHQ-B8 TABLE OF CONTENTS FHQ-B8 Features.............................................................

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data C e i l i n g M o u n t e d C a s s e t t e U n i t w w w. d a i k i n. e u FFQ-B Air Conditioners Technical Data C e i l i n g M o u n t e d C a s s e t t e U n i t w w

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

emura Form. redefined.

emura Form. redefined. emura Form. function. redefined. IT S ALL ABOUT DESIGN if award Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded an if Product Design Award for 2010. For 56 years, the if product

More information

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED

More information

The natural ombination

The natural ombination The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FE18NA has been added. Please void OBH543. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 REVISED EDITION-A Models MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA Indoor

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Daikin Altherma. hybrid heat pump. The natural combination

Daikin Altherma. hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu

More information

The natural ombination

The natural ombination The natural ombination DAikin Altherma Hybrid heat pump system The future is now The new hybrid system Heat pump solution for gas boiler replacement market Daikin Altherma hybrid combines heat pump technology

More information

Inverter technology. bulletin

Inverter technology. bulletin Inverter technology application bulletin What is the inverter component? The inverter is an electronic power component that continuously varies the electricity supply frequency of an electric motor. The

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL CSKS12NB41 & CZ18BT1U + CUKS12NK1A CSKS18NB4UW & CZ18BT1U + CUKS18NKU CSKS18NB4UW & CZ18BT1U + CUKS18NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel)

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO. TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will

More information

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2 SPLIT-TYPE AIR CONDITIONERS Revision E: MUZ-GA24NA and MUY-GA24NA have been added. Please void OB451 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OB451 REVISED EDITION-E Models MUZ-A09NA,-

More information

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type K-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type K-Series Cooling Only Indoor Unit FTXN09KEVJU

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CM97 CM7 CM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No. CM97

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL CSKE1NB41 & CZ18BT1U + CUKE1NK1 CSKE18NB4UW & CZ18BT1U + CUKE18NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) CSKE1NB41 (CZ18BT1U) CSKE18NB4UW (CZ18BT1U)

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH

More information

URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES;

URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES; MODERN AIR CONDITIONERS NOT ONLY COOL BUT HEAT THE AIR AS WELL. YOU CAN ADJUST THE TEMPERATURE IN YOUR HOME ALL YEAR ROUND WITH ONLY ONE SYSTEM. THERE IS MORE THAN JUST A PLEASANT TEMPERATURE NEEDED TO

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

The natural ombination

The natural ombination The natural ombination DAikin Altherma Hybrid heat pump system HEATING & DOMESTIC HOT WATER end user leaflet 2 The future is now 3 and the future is more eco-friendly, energy efficient and cost conscious.

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LKC AS A12LKC OUTDOOR AO R09LKC AO R12LKC 1.INDOOR UNIT : AS A09LKC AS A12LKC DTR_AS039E_01 2010.02.24 1. INDOOR UNIT CONTENTS 1.

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LECA AS G09LECA AS G12LECA AS G14LECA OUTDOOR AO G07LEC AO G09LEC AO G12LEC AO G14LEC 1. INDOOR UNIT : AS G07LECA AS G09LECA AS

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402 TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL CS-KS30NKU + CU-KS30NKUA CS-KS36NKU + CU-KS36NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. CS-KS30NKU CS-KS36NKU Product Code No. 852 360 86

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

Europe Inverter Single 50Hz(R410A) 5RMI0-04B(Replace : 5RMI0-04A)

Europe Inverter Single 50Hz(R410A) 5RMI0-04B(Replace : 5RMI0-04A) Europe 50Hz(R410A) 5RMI0-04B(Replace : 5RMI0-04A) -50Hz(R410A) 1. Models line up 2. Nomenclature 3. Features & Benefits 4. Specifications 5. Dimensions 6. Wiring diagrams 7. Refrigerant cycle diagrams

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair FTXS-L Series FDXS-L Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair FTXS-L Series FDXS-L Series Cooling Only Indoor Unit FTXS30LVJU

More information

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction What is DNSS EcoSave? The Daikin Network Service System (DNSS EcoSave) is a Daikin developed internet based remote

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060 4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER AIR CONDITIONER AIR CONDITIONER TECHNICAL & SERVICE MANUAL INDOOR UNIT : CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

DAikin Altherma low temperature heat pump. end user leaflet

DAikin Altherma low temperature heat pump. end user leaflet DAikin Altherma low temperature heat pump HEATING, COOLING & DOMESTIC HOT WATER end user leaflet 2 The natural choice D 3 in1: heating, cooling and hot water Daikin Altherma is a total heating and domestic

More information

SERVICE MANUAL INDOOR UNIT

SERVICE MANUAL INDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision E: MSZ-GE22VAD- A1 has been added. Please void OBH531 REVISED EDITION-D. INDOOR UNIT SERVICE MANUAL. OBH531 REVISED EDITION-E Models MSZ-GE22VA - A1 MSZ-GE50VA - A1

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

SERVICE MANUAL MXZ-2A20NA MXZ-2A20NA - MXZ-3A30NA MXZ-3A30NA - MXZ-4A36NA OUTDOOR UNIT. No. OB444. Models HFC. Inverter-controlled multi system type

SERVICE MANUAL MXZ-2A20NA MXZ-2A20NA - MXZ-3A30NA MXZ-3A30NA - MXZ-4A36NA OUTDOOR UNIT. No. OB444. Models HFC. Inverter-controlled multi system type Revision C: MXZ-4A36NA have been added. SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Please void OB444 REVISED EDITION-B. OUTDOOR UNIT SERVICE MANUAL HFC utilized R40A No. OB444 REVISED EDITION-C Inverter-controlled

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems

your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems Daikin Airconditioning UK Ltd provides a complete solution for the replacement of R22 systems. Previously, R22 pipe

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information

Air conditioners, Heating & Cooling. Biddle air curtain for connection to daikin heat pumps. www.daikin.eu

Air conditioners, Heating & Cooling. Biddle air curtain for connection to daikin heat pumps. www.daikin.eu Air conditioners, Heating & Cooling Biddle air curtain for connection to daikin heat pumps www.daikin.eu Daikin Europe N.V. DAIKIN, THE COMPANY Daikin has a worldwide reputation based on almost 85 years

More information

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

How To Measure Temperature On A Thermostat

How To Measure Temperature On A Thermostat Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK20HD-S, SRK28HD-S, SRK40HD-S, SRK20CD-S, SRK28CD-S, SRK40CD-S CTENTS 1. GENERAL INFORMATI... 1 1.1 Specific features...

More information

Split System Air Conditioners SkyAir Inverter

Split System Air Conditioners SkyAir Inverter SiUS28-902_a SiUS28-902 06/2009 AK Service Manual / SkyAir Inverter R-410A Heat Pump 60Hz / P Series SiUS28-902 Specifications, designs and other content appearing in this brochure are current as of June

More information

NEW 3-PIPE ECOi MF2 SERIES

NEW 3-PIPE ECOi MF2 SERIES NEW 3-PIPE ECOi MF2 SERIES SIMULTANEOUS HEATING AND COOLING VRF SYSTEM Internet Control Ready INTERNET CONTROL NEW Energy Environmentally friendly refrigerant R410A Down to -20 ºC in heating mode OUTDOOR

More information

SERVICE MANUAL INDOOR UNIT

SERVICE MANUAL INDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision B: "How to check miswiring and serial signal error" for MUZ type has been added. The description about "Low standby power control" has been added to "TECHNICAL CHANGES".

More information

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as: CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living

More information

FTXS. Wall Mount Heat Pump or Cooling Only

FTXS. Wall Mount Heat Pump or Cooling Only FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both

More information

Operating Instructions Split System Air Conditioner

Operating Instructions Split System Air Conditioner Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

FHQ. Ceiling Suspended Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only FHQ Ceiling Suspended Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FHQ ceiling suspended SkyAir systems are ideal for applications without false ceilings. Installed from the structure, this

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

SERVICE MANUAL MU-A09WA MU-A12WA MU-A12WA- 1 OUTDOOR UNIT. No. OB449. Wireless type Models HFC. Revision : A SPLIT-TYPE AIR CONDITIONERS

SERVICE MANUAL MU-A09WA MU-A12WA MU-A12WA- 1 OUTDOOR UNIT. No. OB449. Wireless type Models HFC. Revision : A SPLIT-TYPE AIR CONDITIONERS SPLIT-TYPE AIR CONDITIONERS Revision : A MU-AWA- Please void OB449. has been added. OUTDOOR UNIT SERVICE MANUAL Wireless type Models MU-AWA MU-AWA- HFC utilized R40A No. OB449 REVISED EDITION-A Indoor

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW

More information

SERVICE MANUAL MUZ-HJ25VA MUZ-HJ35VA OUTDOOR UNIT. No. OBH648. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MUZ-HJ25VA MUZ-HJ35VA OUTDOOR UNIT. No. OBH648. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-HJ25VA MUZ-HJ35VA - E1 - E1 Indoor unit service manual MSZ-HJ VA Series (OBH647) MUZ-HJ25VA MUZ-HJ35VA CONTENTS 1.

More information

Technical service manual 2009

Technical service manual 2009 MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual 2009 KSIM MULTI ZONE SERIES R410A DC Inverter multi Series Models KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 CONTENT 1. Product features

More information

How To Power A Car With A Fan And A Fan (Power)

How To Power A Car With A Fan And A Fan (Power) SPLIT TYPE ROO AIR CONDITIONER CEILING WALL TYPE INVERTER Indoor unit AWYZLBC AWYZLBC AWYZLBC AWYZLBC Outdoor unit AOYZLBC AOYZLBL AOYZLBC AOYZLBL CONTENTS SPECIFICATIONS................... OUTLINE AND

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

Refrigeration Compressed Air Dryer Buran Ultrapulse

Refrigeration Compressed Air Dryer Buran Ultrapulse Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6 TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

MDT5N25 & MTD5N40 SERVICE PARTS

MDT5N25 & MTD5N40 SERVICE PARTS MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts

More information

Multi Air Conditioner SVC MANUAL(Exploded View)

Multi Air Conditioner SVC MANUAL(Exploded View) Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A5UW306FA3 CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for

More information

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump Your new Daikin Altherma heat pump In this manual you will find information and guidelines that

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH) Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #44 System Drop-in Tests of Refrigerant R-32 in Single Packaged

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information