Exhaust air device for clean rooms SPWH, SPWV
|
|
- Kory Adams
- 7 years ago
- Views:
Transcription
1 Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA page 159 Exhaust air device for clean rooms SPWH, SPWV Exhaust air devices SPWH and SPWV for clean rooms are intended for ceiling or wall installation in premises where the requirements for very clean air are high, for example clean rooms, pharmaceutical industries, etc. SPWH has duct connection placed at the side of the terminal box and SPWV has duct connection positioned on the top. The device includes a HEPA filter of class H1 or according to PN-EN1822-1, which ensures a very high degree of filtration. Integral measurement sockets in the device mean that the pressure drop can be measured and that any filter leakage can be identified. Excessively high pressure drops across the filter also indicate that it should be replaced. SPW(H,V) is made of painted steel sheet, and its construction makes filter replacement quick and easy. On request diffuser can be also equipped with filter class H11. Product facts Quick selection Product code example: Size (m/h) Max airflow for Max airflow for Airflow l/s at sound level SPW(H,V) with filter H1 SPW(H,V) with filter l/s m/h l/s m/h 0dB(A) 5dB(A) SPW(H,V) 0 SPW(H,V) SPW(H,V) 5 SPW(H,V) (249) 129 (46) 157 (566) (5) 189 (682) 25 (847) 182 (655) 229 (826) 289 (1041) Exhaust air device SPW(H,V) Intended for ceiling or wall installation. Has an integrated connection box. Equipped as standard with a HEPA filter of class H1 or. Four sizes with a broad air flow range. Available either with circular or rectangular connections. Exhaust air diffuser with filter SPWH Device of size 61 with rectangular connection with a HEPA filter of class size 610x610x69mm. Duct connection on the side. In order to keep the work of diffuser normal, it is recommended to not exceed the maximum airflow values given in above table. The diffuser is painted in colour RAL Fläkt Woods PLBOV
2 Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA page 160 Air flow, pressure drop, sound levels SPWH, SPWV H SPWH, SPWV dB(A) 1 H Pressure drop for a complete SPNH, SPNV terminal with an original filter of class H1 and and height of H = 69mm. In the above graphs the sound levels in db(a) are indicated for a reference room with 10 m 2 room absorption, equivalent to 4 db room attenuation. L W = L A10 + K ok Fläkt Woods PLBOV
3 Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA page 161 Air flow, pressure drop, sound levels SPWH, SPWV H1 5dB(A) 0dB(A) SPWH, SPWV dB(A) 1 H1 0dB(A) Pressure drop for a complete SPNH, SPNV terminal with an original filter of class H1 and and height of H = 69mm. In the above graphs the sound levels in db(a) are indicated for a reference room with 10 m 2 room absorption, equivalent to 4 db room attenuation. L W = L A10 + K ok Fläkt Woods PLBOV
4 Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA page 162 Final pressure drop Final pressure drop for terminal with a HEPA filter of class H1 The final pressure drop for the terminal indicates when the filter requires replacement. Measurement is performed with the help of the measurement tube P [Pa] size V[m/h] V[l/s] Final pressure drop for terminal with a HEPA filter of class The final pressure drop for the terminal indicates when the filter requires replacement. Measurement is performed with the help of the measurement tube. 600 P [Pa] size V[m/h] V[l/s] Fläkt Woods PLBOV
5 Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA page 16 Acoustical data, definitions, dimensions The sound power levels for different octave bands are obtained by adding together the sound pressure level L A10, db(a), from the graphs, and the corrections K ok for the octave bands in the table with the help of the following formula: Terminal dimensions B A Dn 0 L W = L A10 + K ok E 1 95 Correction K OK C D Correction K ok in db for Size octave bands, mean frequency, Hz E 2 G B F A 0 62 C D Definitions q air flow l/s, m /h p pressure drop Pa p max final pressure drop (indicates filter replacement) L A10 Pa sound pressure level with a room attenuation of 4 db (10 m 2 room absorption area) db(a) L W sound power level db K ok octave band correction db Size A B C D E 1 E 2 F G Dn All dimensions are indicated in mm. Filter dimensions Size length x width (mm) H (mm) 0 05 x x x x Fläkt Woods PLBOV
6 Exhaust air device for clean rooms SPWH, SPWV TECHNICAL DATA page 164 Descriptive text, product code Descriptive text Supply air terminal SPWH, SPWV for clean rooms for ceiling installation with a HEPA filter of class H1 or and with circular/rectangular duct connection manufactured by Fläkt Woods. Product code Supply air terminal (spigot at the side) SPWH-aa-b-cc-d Diffuser size (0, 45, 5, 61) Duct connection shape 1 = round 2 = rectangular Filter class 1 = H1 14 = Colour 1 = standard RAL 9010 X = any other colour from RAL palette Supply air terminal (spigot on the top) SPWV-aa-b-cc-d Diffuser size (0, 45, 5, 61) Duct connection shape 1 = round 2 = rectangular Filter class 1 = H1 14 = Colour 1 = standard RAL 9010 X = any other colour from RAL palette Fläkt Woods PLBOV
How To Make A Supply Air Ceiling
Supply air ceiling General is a supply air ceiling system with adjustable discs. The spread pattern is infinitely flexible and can be adjusted as required without affecting the airflow, pressure drop or
More informationWTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings
SWANTM WTW Linear slot air diffusers of wall-to-wall design for ceilings Quick facts Wall-to-wall installation Diffuser face of light aluminium design 2, 3 or slots Horizontal/vertical air distribution
More informationSupply air diffuser ROKA/RPKA
Supply air diffuser ROKA/RPKA The ROKA and RPKA are supply air diffusers designed for ceiling mounting. Diffuser ROKA has an unperforated diffuser plate and RPKA has a perforated diffuser plate. The diffusers
More informationSwirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:
VSKA are supply air diffusers designed for ceiling mounting. The design of the air deflectors and discharge outlets causes the air discharged by the diffuser to mix with the air in the premises (high induction
More informationHEPA Terminal Filter Units Types F640, F650, F660
Detail HEPA Terminal Filter Units Types F640, F650, F660»»»» Filter element dust loading is detected and indicated by an LED Used in medicine, biology, the pharmaceutical industry, and other sensitive
More informationAirline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
More informationINDEX. Chapter8. air master. Perforated Ceiling Diffusers
Chapter8 INDEX A. Perforated ceiling diffuser 1. Perforated ceiling diffuser with plenum box..: APCD+P...8.1. Perforated ceiling diffuser with damper....: APCD...8. Standard sizes...8. Fixing details...8.
More informationEASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. LIFE IN PURSUIT OF QUALITY FROM THE VILLAGE FORGE TO A GLOBAL CORPORATION The Directors of AL-KO KOBER SE (from right to left): Stefan Kober (CEO),
More informationFundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer
Fundamentals of Acoustics & Practical HVAC Design Considerations Demir Doken Acoustic Engineer What is sound? Sound is a mechanical wave that is an oscillation of pressure transmitted through some medium
More informationTrans Bay Cable Project (400 MW) Preliminary Audible Noise Study
Page 1 of 5 Preliminary Audible Noise Study Pittsburg 10 th Street, N-S Orientation Rev. Date Section Page Remarks Signature 0 17.11.06 all all first issue Page 2 of 5 1 Audible Noise Study 1.1 Basis The
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationTechnical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
More informationPart H DIFFUSERS section 2 SEPT 2005. Publication. Air Diffusers. supply and exhaust ventilation systems. plenum boxes
Publication Part H DIFFUSES section 2 SEPT 5 Air Diffusers supply and exhaust ventilation systems plenum boxes PLENUM BOXES introduction The general range of PB plenum boxes are manufactured with a return
More informationCONTROL/SLAVE Zone. Zone damper for Swegon s WISE System for demand-controlled ventilation
CONTROL/SLAVE Zone Zone damper for Swegon s WISE System for demand-controlled ventilation Quick facts Pressure regulation from -300 Pa Flow measurement or flow regulation Optimisation of supply- and extract
More informationAcoustic Design Guide. NR and NC Curves CIBSE Noise Ratings Environmental Noise Control Maximum Air Velocities in Ducts Privacy in Cellular Offices
Acoustic Design Guide NR and NC Curves CIBSE Noise Ratings Environmental Noise Control Maximum Air Velocities in Ducts Privacy in Cellular Offices 14th February 2012 Contents Noise Curves NR Curves and
More informationOptiffuser. High-performance, high bandwidth lightweight 1D diffuser.
Optiffuser High-performance, high bandwidth lightweight 1D diffuser. General product information The Optiffuser comes in packs of four panels. Two positives and two negatives (see page 5) per package.
More informationBACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS
CI/SfB (57) Uniclass L753 October 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS... PRODUCT RANGE AND OVERVIEW..................................................................................
More informationInstallation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG
Installation and Operating Manual Model F1800C Model F1800PG Model F180C Model F180PG Model F1806C Model F1806PG www.ipsystemsusa.com Contents Safety Warnings... Items supplied... Description... Installation...4
More informationLaminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) 1842 754545 Telefax +44(0) 1842 763051 e-mail trox@troxuk.co.uk www.troxuk.co.
2/2./B/2 Laminar Flow Panel Type LFP TROX UK Ltd Caxton Way Thetford Norfolk IP2 3SQ Telephone +(0) 182 7555 Telefax +(0) 182 763051 e-mail trox@troxuk.co.uk www.troxuk.co.uk Contents Description Description
More informationDirect and Reflected: Understanding the Truth with Y-S 3
Direct and Reflected: Understanding the Truth with Y-S 3 -Speaker System Design Guide- December 2008 2008 Yamaha Corporation 1 Introduction Y-S 3 is a speaker system design software application. It is
More informationTFSR & TFSK Roof Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof
More informationFilter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
More informationSPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems
SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems WILLIAM KUFFNER, M.A. Sc., P.Eng, PMP Senior Fire Protection Engineer Director Fire Protection Engineering October 30, 2013 Code Reference
More informationTechnical catalogue convectors POLAND 2012
Technical catalogue convectors POLAND 2012 index convectors review...3 Narbonne...4 Narbonne VT... 10 Narbonne V... 16 Narbonne V VT... 20 mounting distances for Narbonne...26 mounting distances for Narbonne
More informationAir Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90
6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2
More informationAir-water systems for efficient air conditioning
Air-water systems for efficient air conditioning The art of handling air System overview Passive cooling systems Induction units Façade ventilation units Page 4 Page 6 Page 10 Passive Chilled ceiling Undersill
More informationAffordable Sports Halls
Creating a sporting habit for life Appendix 5 Acoustics (To be read in conjunction with the main document) Speech Intelligibility with 40dBA Ambient Noise (BB93 Compliant) Affordable Sports Halls August
More informationExhaust noise control case study for 2800 class locomotive
Exhaust noise control case study for 2800 class locomotive Briony CROFT 1 ; Steve BROWN 2 ; Aaron MILLER 3, Andrew PARKER 4 1 SLR Consulting (Canada) Ltd, Canada 2,3,4 SLR Consulting Australia Pty Ltd,
More informationAn update on acoustics designs for HVAC (Engineering)
An update on acoustics designs for HVAC (Engineering) Ken MARRIOTT To cite this version: Ken MARRIOTT. An update on acoustics designs for HVAC (Engineering). Société Française d Acoustique. Acoustics 2012,
More informationsqurboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
More informationSALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units
SALES BULLETIN Key Features 1. Chassis completely re designed 2. Increased product range, now includes 6HP model 3. New features to enable easy installation a. Easy access hanger b. Easier wiring connections
More informationE D I T I O N 2 0 1 3 1
1 EDITION 2013 W E L C O M E T O F I R S T C L A S S W E L C O M E T O F I R S T C L A S S 2 3 Sirius S.p.a., established in 1996, operates in the residential air ventilation and purification market sector,
More informationAcoustic design according to room type
according to room type The purpose of the room is decisive for the acoustic environment to be created. In rooms for speech, such as classrooms and auditoriums, it is important to ensure a good level of
More informationDéfumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
More informationGrilles & Diffusers Series LFP Incorporating
Grilles & Diffusers Incorporating Series LFP Produce a stable linear throw, creating an area of clean air with minimal diffusion Perfect for areas like clean rooms and operating theatres Tile replacer
More informationIncorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles
Incorporating V2.3 Product spec >>> > Series ECG - Egg Crate Grilles > Series ECG45-45 Egg Crate Grilles Grilles Egg crate Recommended for: Wall, ceiling & duct Extract Overview Industry standard extract
More informationplenum slot diffusers
light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4
More information2011-06-13. Acoustic design with wall acoustic solutions
2011-06-13 Acoustic design with wall acoustic solutions Introduction A suspended ceiling is by far the most common acoustical treatment in a room. In most cases this is also a sufficient solution to create
More informationTD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans
IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8
More informationBuilding Design for Advanced Technology Instruments Sensitive to Acoustical Noise
Building Design for Advanced Technology Instruments Sensitive to Acoustic Noise Michael Gendreau Colin Gordon & Associates Presentation Outline! High technology research and manufacturing instruments respond
More informationTesting laboratory HVAC. Test report No.: HP-06525-e
Testing laboratory HVAC Test report No.: HP-62-e Objective: Sound measurements on an air distribution box and an air inlet Client: RoomAir AG Thurstrasse 14 Postfach 81 Frauenfeld Date: 26-6-2 This report
More informationPLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB
OVERVIEW TYPE: GGB All composite construction Rigid extruded upvc aerofoil blade section Integral blade seals for low leakage operation Individual blades driven via reinforced styrene gear wheels in maintenance
More informationCADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
More informationRittal TopTherm fan-and-filter unit
Rittal TopTherm fan-and-filter unit System Climate Control More pressure. Higher air flow rates. 2 Assembly without tools Straightforward assembly, exchange and maintenance with no need for tools of any
More informationInstallation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
More informationAMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY
PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall
More informationLiebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
More informationRelationship between Sound Pressure and Sound Power Levels
Relationship between Sound Pressure and Sound Power Levels 4 W. T. W. CORY Chairman of the Eurovent WG 1 Fans If we wish to know the sound power transmitted through a fan and ducting system, it is preferable
More informationProduct Information. Tel: 905.696.9900 x2426 or x2443 Fax: 905.696.9300 Email: sales@alusion.com
Tel: 905.696.9900 x2426 or x2443 Fax: 905.696.9300 Email: sales@alusion.com Product Information 6320-2 Danville Rd. Mississauga, Ontario Canada L5T 2L7 TABLE OF CONTENTS Sheet Product Alusion Sheet Products.......................................................
More informationPART VIII: ABSORPTIVE SILENCER DESIGN
PART VIII: ABSORPTIVE SILENCER DESIGN Elden F. Ray June 10, 2013 TABLE OF CONTENTS Introduction 2 Silencer Performance 4 Flow Resistance and Resistivity 7 Flow Velocity 7 Baffle Attenuation Example 7 Silencer
More informationBasics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
More informationAir Comfort. Technical Catalogue > Roof Fan STOF
Air Comfort Technical Catalogue > Roof Fan STOF Roof_fan_stof_GB_2014.03.06.indd 1 2014-03-06 13:33 Contents ROOFMASTER - STOF vertical...3 Performance Data...4 Performance Table...7 Product and Electrical
More informationOwners Manual. Three-Way Architectural Speaker. www. artcoustic.com
Owners Manual Three-Way Architectural Speaker www. artcoustic.com Architect SL Three-Way Architectural Speaker Features: - X2 bass system, extended low frequency - Extremely small and compact design -
More informationDisplacement ventilation
General The displacement ventilation principle is the oldest form of ventilation and can be achieved without the use of fans. Air movement occurs by means of the density differences between supply air
More informationRKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
More informationClinic Washer-Disinfectors. Washer-Disinfector Line
Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative
More informationFlexit air handling unit K2 R
Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT Requirement-controlled
More informationEcophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x600. 1200x600 1200x1200 1600x600 M206, M208, M238
Ecophon Focus Ds For applications where a suspended ceiling with a concealed grid is required, but individual tiles must be easily demountable. Ecophon Focus Ds has a concealed grid and syetrical edge
More informationEcophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x600 1200x1200 1600x600
Ecophon Focus A For applications where a robust suspended ceiling system is required. Ecophon Focus A has an exposed grid system. Each tile is easily demountable. The systems consist of Ecophon Focus A
More informationSound Power Measurement
Sound Power Measurement A sound source will radiate different sound powers in different environments, especially at low frequencies when the wavelength is comparable to the size of the room 1. Fortunately
More informationBENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: BENCH TECH 150 General information Type of instrument: Bench chemical hood. Model: Bench Tech 150. Code: 50-150-201 Description:
More informationSaint-Gobain Ecophon Limited RIBA Accredited CPD Seminar
Ecophon Limited Module 1: Ceiling Design Solutions Design Issues: Supporting the room function Module size, Edge detail, Shape, Colour Integration (lighting, ventilation, walls, partitions) Layout, Access
More informationHVAC Acoustic Fundamentals
Application Guide AG 31-010 HVAC Acoustic Fundamentals Decibel Sound Pressure Pascals 140 120 100 80 60 40 20 0 100 10 1.0 0.1 0.01 0.001 0.0001 0.00002 Barrier S1 BD BH R1 Measurement Point Path Length
More informationCoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
More informationHDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
More informationsound reduction systems for commercial, educational and industrial environments
sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic
More informationNoise in the Classroom
ASHRAE JOURNAL Copyright 2000, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. This posting is by permission of ASHRAE Journal. This article may not be copied nor distributed
More informationPAGE 2. Figure 1: Difference between PWL ins and SPL 1m
PAGE 1 Pipe noise J.H. Granneman and R.P.M. Jansen, Peutz Consulting Engineers, The Netherlands, emphasise the need for an adequate pipe noise control procedure, with reference to the design phase, insulation
More informationThe High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
More information>1@$UFKLWHFWXUHDFRXVWLFVPHDVXUHPHQWVDQGGHVLJQDFKXUFK DQGDQDXGLWRULXP
7KHQG,QWHUQDWLRQDO&RQJUHVVDQG([SRVLWLRQRQ1RLVH&RQWURO(QJLQHHULQJ -HMX,QWHUQDWLRQDO&RQYHQWLRQ&HQWHU6HRJZLSR.RUHD $XJXVW >1@$UFKLWHFWXUHDFRXVWLFVPHDVXUHPHQWVDQGGHVLJQDFKXUFK DQGDQDXGLWRULXP First Author:
More informationMarine Generating Sets 3.7 to 50 kva
Marine Generating Sets 3.7 to 50 kva The Marine Engineer s Preference BetaSet - Standard Marine Generators Beta Marine has considerable experience from over twenty years of manufacturing marine generating
More informationIH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
More informationExperiment (13): Flow channel
Introduction: An open channel is a duct in which the liquid flows with a free surface exposed to atmospheric pressure. Along the length of the duct, the pressure at the surface is therefore constant and
More informationDEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING
DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING Toshiharu Kagawa 1, Yukako Saisu 2, Riki Nishimura 3 and Chongho Youn 4 ABSTRACT In this paper, we developed a new laminar flow
More informationFlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.
Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. Vertical Laminar Flow Cabinets BEYOND MINIMUM SAFETY REQUIREMENT Cabinets are ISO Class 3 vertical laminar flow cabinets which
More informationLeeds Metropolitan University - Design and Build of new Acoustic Laboratory Suite
http://www.pdaltd.com Leeds Metropolitan University - Design and Build of new Acoustic Laboratory Suite Introduction Leeds Metropolitan University (LMU) is a well established and respected centre for education
More informationVideo conference solutions
149 Video conference solutions Video conference solutions Communication was never easier than with the Audipack videoconferencing solutions. Furniture, camera drawers, camera lift systems for every situation
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationNEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!
Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I
More informationTelepresence T3 Room recommendations
T3 Room Recommendations Guide Important Notice: As per 21 March 2013, the text in the first paragraph on page 12 regarding the HVAC (Heating, Ventilation, Air Conditioning) requirements has been rectified
More informationQZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR-13-2-2-1
Key features Vertical or horizontal installation Cooling ( pipes) Heating ( pipes or electrical heater) Available pressure up to 80 Pa ECM version for low energy consumption In line with innovative trends
More informationFigure 1 : Typical Computer Simulation of a Bass Reflex Speaker
Introduction : Over the past few years, I have become very aware of the baffle step response phenomenon associated with drivers mounted in rectangular shaped baffles. My first quarter wavelength designs
More informationBasic Selection & Proper Application of Overhead Air Distribution Devices
Basic Selection & Proper Application of Overhead Air Distribution Devices GRD Selection & Application Terms Selection Throw Sound Installation Variations affect Performance Inlet Effects Basics Return
More informationExhaust Calculation Booklet
Exhaust Calculation Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry.com ADC Part No. 450450 Exhaust
More informationAcoustical Design for Concert Hall in the Science and Art Centre of Xiamen University
Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University Yuezhe Zhao, Shuoxian Wu State Key Laboratory of Subtropical Building Sciences, South China University of Technology,
More informationHow To Buy A Designo Grille
anal ompact anal Plus 1 2 3 1. omplete anal Plus underfloor unit 2. Heat exchanger and inside finish of the duct in dark grey 3. Enlarged range of grilles anal Plus Operating principal Options Flexible
More informationANSI/AHRI Standard 880 (I-P) with Addendum 1. 2011 Standard for Performance Rating of Air Terminals
ANSI/AHRI Standard 880 (I-P) with Addendum 1 2011 Standard for Performance Rating of Air Terminals Approved by ANSI on October 27, 2011 WITH ADDENDUM 1, PERFORMANCE RATING OF AIR TERMILS June 2012 Note:
More informationCBA Volume: Student Sheet 1
CBA Volume: Student Sheet 1 For each problem, decide which cube building has more room inside, or if they have the same amount of room. Then find two ways to use cubes to check your answers, one way that
More informationThe Role of Acoustics in Curtain Wall Design:
The Role of Acoustics in Curtain Wall Design: Strategies to Achieve Desired Performance Criteria April 22, 2015 John LoVerde, Principal VENEKLASEN ASSOCIATES, INC. Goals Basics of Acoustics Ratings in
More informationCELO5. User & Installation Manual. www.audac.eu
CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt
More informationTURBOWENT TULIPAN - rotary chimney cowl Ø150
Picture Function principle rotation direction Wind Chimney draught Description Rotary chimney cowl Turbowent Tulipan is a device, which, in a dynamic way, uses force of the wind to increase chimney draught.
More informationHigh-speed spiral doors for deep-freeze applications. TK Series
High-speed spiral doors for deep-freeze applications TK Series 02 TK Series The cold chain for deep-frozen products must never be interrupted during storage and transport. This demands an enormous amount
More informationAMD-33 Air Measuring Station with VCD-33 Control Damper
Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
More informationHow To Get A Passive House
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2015 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Product
More informationA novel approach of multichannel and stereo control room acoustic treatment, second edition
Audio Engineering Society Convention Paper Presented at the 140th Convention 2016 June 4 7 Paris, France This convention paper was selected based on a submitted abstract and 750-word precis that have been
More informationTHE ACOUSTICS OF THE "NUOVO TEATRO COMUNALE" IN CAGLIARI
Roberto Pompoli(1), Angelo Farina(2), Patrizio Fausti(1) (1) Istituto di Ingegneria, University of Ferrara, Italy (2) Dipartimento di Ingegneria Industriale, University of Parma, Italy 1. ABSTRACT In 1967,
More informationCleanroom Solutions Ltd T: 01273 760 060 F: 01273 760 061 E: mail@cleanroom-solutions.co.uk W: www.cleanroom-solutions.co.uk
Cleanroom Solutions Ltd T: 01273 760 060 F: 01273 760 061 E: mail@cleanroom-solutions.co.uk W: Introduction Cleanroom Solutions Ltd has a wealth of experience together with a solid track record in the
More informationChilled Water Fan Coil Unit. Model:HFCA Size 03~14
Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal
More informationCharacterization of acoustics in open offices - four case studies
Characterization of acoustics in open offices - four case studies J. S Keränen, P. Virjonen and V. O Hongisto Finnish Institute of Occupational Health, Lemminkäisenkatu 14-18 B, 5 Turku, Finland jukka.keranen@ttl.fi
More information8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!
Bathroom and toilet extract fans SILENT-100 BATHROOM EXTRACT FANS SILENT-100 Series SILVER versions The SILENT-100 CZ and CRZ can be supplied Range of axial extractors with airflow rates of approx. 95
More information