Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages."

Transcription

1 Défumair XR smoke-extraction fan extraction casing for kitchen at F Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally mounted padlockable on/off switch. Personalised offer : double-skin insulation. Smoke Extraction protection pack : relay box electrically connected in factory. range Range consists of 8 models (turbine Ø 400 to 900 mm) : - Flow from to m 3 /h. - Motorisation : 1 speed 4 poles variable. 1 speed 6 poles variable. 2 speeds - 4/8 poles Dahlander. - 6/12 poles Dahlander. - 4/6 poles W.I. - 6/8 poles W.I. designation Défumair XR 400 T I VAR Name size Polarity T = Three-phase Insulation Motorisation Direct drive motor double skin var = variable Backward impeller - Hz version : consult us. Défumair XR Protection Pack : - Relay box electrically connected to fan. application Smoke extraction in tertiary buildings IGH and ERP. Extraction of smoke, steam, pollutants previously collected by the hood equipped with filters. construction / composition Case : - Made of galvanised steel sheet with upstream and downstream connecting flanges and access doors. Motor support : - Galvanised steel plate, motor with flanges fixed on 2 poles. Removable plate/support/impeller set. Impeller : - Backward type centrifugal, in galvanised steel, dynamically balanced. - Direct drive on the motor shaft. Motorisation : Flanged motor IP 55 class F 50 Hz service S1. - Three-phase 230/400 V 50 Hz 1 speed : 4 poles for models : poles for models : Three-phase 400 V - 50 Hz - 2 speeds Dahlander coupling: 4/8 poles for models : /12 poles for models : Three-phase 400 V - 50 Hz - 2 speeds independant windings : 6/8 poles for models /6 poles for models 400. Standard proximity switch : - Padlockable switch with position contacts, fixed on the appliance, complying with the labour code and norm NFS packaging Banded and film-wrapped on pallet. specifications Extraction fan casing is made of galvanised steel with access doors to facilitate transport and maintenance operations. It will be equipped with a backward impeller coupled directly on the motor and mounted on removable panels. It will have fire resistance F Type Défumair XR, France Air brand. fire grade - label CE Accredited Comfort - Smoke extraction. Accredited F : extraction at 400 C for 2 hours according to norm EN Compliance certificat CE given by the CTICM. 318 Guide created by France Air All rights reserved.

2 technical description Dimensions, reservation and weight Unit Défumair Push-back frame, protection hood, support feet Type A B C D E F G H I 19 18, J Ø K Ø L M N P R T * Kg ** dimensions in mm * On models XR800 6/8, XR800 6/12 : mm. ** Weight without motor A * B * C D E F G1 46, H I J K L M dimensions in mm * On models XR800 6/8, XR800 6/12 : mm. Limits of use Temperature of continuously transported fluid maximum 80 C. Internal or external installation, standard version with adapted accessories. Guide created by France Air 2010 All rights reserved. 319

3 technical description Motor features XR 400 XR 450 XR 500 XR 5 XR 630 XR 710 XR 800 XR speed 4 Poles (kw) 0,55 1,1 1, Axle height of the motor (mm) Tension (V) Intensity (A) 1,6 2,84 3,19 6 7, Weight (kg) speed 6 Poles (kw) 0,18 0,37 0,55 1,1 1,5 3 5,5 11 Axle height of the motor (mm) Tension (V) Intensity (A) 0,77 1,21 1, 3,90 3, ,2 22,8 Weight (kg) speeds 400 V 4/8 Poles (kw) 0,6/0,15 1,2/0,3 1,6/0,3 2,8/0,7 3,8/1, Axle height of the motor (mm) Intensity (A) 1,67/0,72 3,23/1,43 4,05/1,78 6,44/2,63 8,20/2, Weight (kg) speeds 400 V 6/12 Poles (kw) - - 0,5/0,14 1,5/0,25 1,5/0,25 3/0,55 5,5/1,1 11/1,8 Axle height of the motor (mm) Intensity (A) - - 2,50/1,10 4,55/1,67 4,55/1,67 6,77/2,30 14,0/6,0 24,5/8,20 Weight (kg) speeds 400 V 6/8 Poles (kw) - 0,55/0,37 0,75/0,37 1,1/0,55 1,5/0,75 3/1,5 5,5/2,75 - Axle height of the motor (mm) Intensity (A) - 2,04/1,92 2,68/1,67 3,15/2, 4,00/3,00 7,96/3,75 12,2/8, - Weight (kg) speeds 400 V 4/6 Poles (kw) 0,55/0, Axle height of the motor (mm) Intensity (A) 1,69/0, Weight (kg) selection graphs Type B Acoustic pressure level in db(a) at 6 meters. Ducted intake/free discharge. Measure done in free area, directivity 2. A 53 Example A : model Défumair XR 400 in at point A : 1 0 m 3 /h and 375 Pa of total pressure corresponds to an electric power B absorbed at 5 W Note : The absorbed powers are given for 1 speed motors, except for the XR 710-, and P that are given for 2 speeds motors. 46 Type Guide created by France Air All rights reserved.

4 selection graphs Type Type Acoustic pressure level in db(a) at 6 meters. Ducted intake/free discharge. Measure done in free area, directivity 2. Note : The absorbed powers are given for 1 speed motors, except for the XR 710-, and P that are given for 2 speeds motors Type Guide created by France Air 2010 All rights reserved. 321

5 selection graphs Type Type Acoustic pressure level in db(a) at 6 meters. Ducted intake/free discharge. Measure done in free area, directivity 2. Note : The absorbed powers are given for 1 speed motors, except for the XR 710-, and P that are given for 2 speeds motors Type Guide created by France Air All rights reserved.

6 personalisation Défumair XR Protection Pack The protection pack is a complete offer ready to use. It includes all wiring operations between the fan and the relay box with padlockable switch and pressostat. 2 versions : Smoke extraction Pack Smoke extraction External Comfort Pack Simplified installation - Saves time - Relay box with pressostat and padlockable switch electrically wired to fan. Respects the security rules - Wiring complies to the norm NFS Installation rules of Fire Security Systems (SSI). Selection principle : - Optimised offer when the relay box is near the fan. - Select a Défumair XR Protection Smoke Extraction Protection Pack 1 speed or 2 speeds. Relay box Ordinys with : - padlockable switch, - pressostat with fireproof cable, - pressure pipe for aeraulic connection, - protection visor for exterior installation. - 2 ml of fireproof cable between the fan and the casing. accessories Rectangular flexible sleeve Suction frame/circular exhaust and circular flexible sleeve Rain visor To be fixed on the exhaust side, for outside mountings of the fan casing. Equipped with bird screen. Motor hood To be used when the Défumair is installed outside. To be fixed on the motor support, it protects the motor from bad weather. In galvanised steel sheet. Supports Fixed under unit, allow the installation of anti-vibration mountings. Differential pressostat 20 to 300 Pa Connection scheduled for pressure measurement. Mounting accessories delivered with the product : - 1 fixing square + mounting screws on air duct. - 2 easy connections. - 1 plastic pipe of 2 m. - IP 54 box. Antivibration mountings Type BCA : These supports are made with 2 flat parallel plates fastened together with a rubber ring. Type PAR : V type steel spring return mountings, with light and moulded metal housing for antivibration mounting and acoustic insulation. Switch three-phase 1 speed on/off Box sealed IP55. No overload protection. On/Off circuit breaker box Three-phase 400 V - 1 speed. With warning contact. Box sealed IP 55. Magnetothermical intensity set up. Ipsothermic sensor start. Frequency convertor 2 versions : - IP 54 : Senseo Drive. - IP 20 : Soft Drive. On/Off button and seperated potentiometer. Accurate and immediate adjustement of air flow. IP 54 IP 20 On/Off switch three. 2 speeds Dahlander Three-phase 2 speeds. Switchable poles. On/Off switch Independant winding. Three-phase - 2 speeds. Independant windings. 2 speeds three-phase switch box Dahlander Independant windings. Box sealed IP55 ensuring on/off operation, the change from one speed to another, the thermal protection, and the gas electro valve control. Independant winding 2 speeds Three-phase switch box Independant windings. Guide created by France Air 2010 All rights reserved. 323

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

TFSR & TFSK Roof Fans

TFSR & TFSK Roof Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof

More information

ErP POWERBOX GF FANS - ESTOC TARGE FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

ErP POWERBOX GF FANS - ESTOC TARGE FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR 129 POWERBOX GF FANS - ESTOC TARGE FEATURES Sizes from 355 to 63 mm diameter Air flow up to 4. m 3 /s Static pressures up to 13 Pa Adjustable controllable external rotor motors Multiple outlet orientations

More information

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None Low and High Static Pressure Fan Coil Units VH2N 03 to 27 Technical Brochure TM VH2N-A.1GB Date : June 2006 Supersedes : None Design Features Presentation The VH2N fan coil units has been specially designed

More information

High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual

High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual 2 GEYSER MINI Reversible heat pump Index Technical features 120 Basic version general technical data 124 Basic

More information

ICQ Series - square centrifugal

ICQ Series - square centrifugal product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ

More information

Name: MUB E4 SILEO MULTIBOX Item no.: Version: 50 Hz; 90 airflow

Name: MUB E4 SILEO MULTIBOX Item no.: Version: 50 Hz; 90 airflow MUB 042 500E4 SILEO MULTIBOX Item no. 37901 Document type: Product card Document date: 2016-03-17 Generated by: Systemair Online Catalogue Version: 50 Hz; 90 airflow Description Speed-controllable Modular

More information

VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS

VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS Vertical multistage centrifugal electric pumps stainless steel. APPLICATIONS Treating water Industrial washing systems Heating and air conditioning Water supply and boosting Agriculture Irrigation TECHNICAL

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES

TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES TECHNICAL MANUAL HEAT RECOVERY UNITS URE SERIES SUMMARY 1. GENERAL FEATURES 2 2. VERSIONS AND COMPONENTS 2 3. ORIENTATIONS 3 4. NOMINAL TECHNICAL DATA 4 5. AVAILABLE ACCESSORIES 5 6. FAN CHARACTERISTICS

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

O-I DUBI PLANT FANS Quotation Spec Data & Specifications TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement

More information

High Static Pressure Ductable Fan Coil Unit Models 07 to 27

High Static Pressure Ductable Fan Coil Unit Models 07 to 27 VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 5.3 to 26.9kW 4.1 to 22.6kW 800 to 4650 m 3 /h VH 1 General Characteristics Presentation The new ducted high static pressure fan coil units

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

Fan & Blowers. Motorized Impellers and Centrifugal Blowers. Backward & Forward Curved 2 & 4 Pole Motors Single & Dual Inlet. FB 01.

Fan & Blowers. Motorized Impellers and Centrifugal Blowers. Backward & Forward Curved 2 & 4 Pole Motors Single & Dual Inlet. FB 01. Fan & Blowers Motorized Impellers and Centrifugal Blowers Backward & Forward Curved 2 & 4 Pole Motors Single & Dual Inlet FB 1.12 January 212 1 HVAC Air Movers Designed for Hard Work and Long Service Motor

More information

Packaged Air Conditioner - Water Cooled Vertical Type Model 25

Packaged Air Conditioner - Water Cooled Vertical Type Model 25 Refrigerant R407C CX Packaged Air Conditioner - Water Cooled Vertical Type Model 25 8.0kW CX 25 1 Product Code Model Power supply Product code CX 25 230V / 1 ~ / 50 Hz 7XU012153 CX 25 CX 25 2 CX 25 General

More information

MAX-TEMP CTHB / CTHT Centrifugal F Rated Fans

MAX-TEMP CTHB / CTHT Centrifugal F Rated Fans ROOF MOUNTD FANS MAX-TMP TH / THT entrifugal F400-120 Rated Fans Range of centrifugal roof mounted fans in horizontal discharge format, designed for smoke extraction in fire conditions and certified F400

More information

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual V - JET Counteflow System V-JET Counterflow System Installation and Operation Manual 1. System Installation By purchasing the V - JET counterflow system you have obtained high-quality product, which will

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER

CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER CASE STUDY 1 COMMISSIONING A GAS FIRED STEAM BOILER A steam boiler has been built and installed at a factory for the provision of process steam. The following lists the requirements used in the commissioning

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

CR15-07 A-F-A-E-HQQE 3x400D 50 HZ

CR15-07 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR15-7 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651898 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651898/cr-15-7-a-f-a-e-hqqe.html

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Electric resistors for Roof Top ACTIVA

Electric resistors for Roof Top ACTIVA Electric resistors for Roof Top ACTIVA 045-090 Options and Accessories, Installation manual Ref.: N-40334_EN 0909 Index Index 1 Electric resistors for Roof top ACTIVA 045-090... 1 1.1 Electric resistor

More information

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES

More information

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting

K1H014MLH cam ammeter switch - 4 circuits A - screw mounting Characteristics cam ammeter switch - 4 circuits - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

ITT. Goulds Pumps 33GS, 40GS, 55GS, 60GS, 75GS & 80GS. Engineered for life B33-80GS. Residential Water Systems FEATURES

ITT. Goulds Pumps 33GS, 40GS, 55GS, 60GS, 75GS & 80GS. Engineered for life B33-80GS. Residential Water Systems FEATURES B33-8GS ITT Residential Water Systems Goulds s 33GS, 4GS, 55GS, 6GS, 75GS & 8GS 33-8, 1 1 HP, 6 Hz, Submersible s Goulds s is a brand of ITT Corporation. www.goulds.com Engineered for life FEATURES n Powered

More information

VS-GCR Manual Reset Normally Closed Gas Valves

VS-GCR Manual Reset Normally Closed Gas Valves Page 1 of 6 VS-GCR Manual Reset Normally Closed Gas Valves Features: EN 161 Class A, Group European approval 230Vac or 24Vac solenoid coil options Flanged and screwed types Optional Closed Position Indicator

More information

DX Condensing Units for both cooling and heat pump applications

DX Condensing Units for both cooling and heat pump applications DX for both cooling and heat pump applications 3 VES Andover offer a comprehensive range of condensing units for both cooling only and heat pump application, designed to match your VES air handling unit.

More information

Doors. Type BS. Inspection access doors for filter chambers, air handling units or other enclosures with machinery or equipment.

Doors. Type BS. Inspection access doors for filter chambers, air handling units or other enclosures with machinery or equipment. .1 X X testregistrierung Doors Type Double lever locking device interior lever Removable front locking lever (of double lever locking device) Cylinder rim lock Inspection window Inspection access doors

More information

Technical Catalogue > Axial Fans

Technical Catalogue > Axial Fans Technical Catalogue > Axial Fans Contents JM Aerofoil - Cased Axial Fans...5 - L Type...6 Performance Chart - 315-355 mm, 2 Pole...6 Performance Table - 315-355 mm, 2 Pole...6, Electrical and ErP Table

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 129,8/103,8 143,0/114,4 199,18 400/ ,8 129,8/103,8 143,0/114,4 206,65

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 129,8/103,8 143,0/114,4 199,18 400/ ,8 129,8/103,8 143,0/114,4 206,65 TECHNICAL SPECIFICATIONS Model: AD-145 Stand-by automatic gen set. Image for guidance purposes. (400 / 230 V) ENGINE MAKE DEUTZ MODEL BF4M 1013 FC CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 130

More information

CI/SfB (57.7) 1st Edition. Sabre Sickle Fan Range - Incorporating the FE2 Owlett impeller. Vent-Axia Industrial Range

CI/SfB (57.7) 1st Edition. Sabre Sickle Fan Range - Incorporating the FE2 Owlett impeller. Vent-Axia Industrial Range CI/SfB (57.7) 1st Edition Vent-Axia Industrial Range Sabre Sickle Fan Range - Incorporating the FE2 Owlett impeller Sabre Sickle Fans Vent-Axia Sabre Sickle Fans The latest Vent-Axia Plate and Case Sabre

More information

ErP ROOF UNITS - ROOFMASTER STOF SHUTTER FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES MATERIAL AND DESIGN PRODUCT CODE - STOF-190-SAC-102-0

ErP ROOF UNITS - ROOFMASTER STOF SHUTTER FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES MATERIAL AND DESIGN PRODUCT CODE - STOF-190-SAC-102-0 151 ROOF UNITS - ROOFMASTER STOF SHUTTER FEATURES 8 sizes Volume flows up to 4.7 m 3 /s Static Pressures up to 950 Pa Both EC- and AC-versions available Low sound level High efficiency Speed controllable

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

SPECIFICATION DGK25C

SPECIFICATION DGK25C SPECIFICATION DGK25C CONTENTS CHAPTER 1: GENERAL STANDARDS & CONDITIONS 1 1. DESIGN STANDARDS 1 2. DESIGN CONDITIONS 3. FACTORY INSPECTION 4. PAINTING PROCESS CHAPTER 2: EQUIPMENT SPECIFICATIONS 2 1. OVERALL

More information

power moving forward KVA RANGE Performance I Durability I Serviceability

power moving forward KVA RANGE Performance I Durability I Serviceability www.fgwilson.com power moving forward 225 375 KVA RANGE Performance I Durability I Serviceability Uninterrupted power is essential to everyday modern life, FG Wilson is here to be your power moving forward.

More information

Water Chillers - The range CH and RPW series

Water Chillers - The range CH and RPW series Water Chillers - The range CH and RPW series PIOVAN S.p.A. Cooling Centre 1 (1) Piovan Chiller Range Piovan Spa 03.2004 Modification reserved Water chillers A dedicated Cooling Centre Integration with

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

PLATE HEAT EXCHANGER UNITS

PLATE HEAT EXCHANGER UNITS PLATE HEAT EXCHANGER UNITS Provide 50-65% heat recovery Round and square spigot versions Ideal for confined areas Duty of 0-2.0m 3 /s Easy installation VES PLATE HEAT EXCHANGER UNITS part of a complete

More information

SUBMERSIBLE PUMPS AFP 0831 to 2046

SUBMERSIBLE PUMPS AFP 0831 to 2046 SUBMERSIBLE PUMPS AFP 0831 to 2046 DIN/EN 12050-1 Robust, reliable sewage pumps from 1.3 to 22 kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and communal

More information

MCA MCA (R-407C) SPLIT SYSTEM

MCA MCA (R-407C) SPLIT SYSTEM 21-1 MCA 21-1 AIR COOLED CONDENSING UNIT (COOLING ONLY) FOR INDOOR INSTALLATION MCA 21-1 (R-40C) Size Cooling [kw] 21.4 2.91 1.4 41.0 1 14.1 1 20. 91 2. 101 1.9 1. These units are used in split type installation

More information

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18 ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

1 General description

1 General description Specification SERIES: SyScroll 20-30 Air EVO HP TYPE: Air to water inverter driven heat pump TECHNOLOGY: scroll compressor / inverter driven CAPACITY RANGE: Cool ing 20-35 [kw] Heating 20-34 [kw] 1 1 General

More information

SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 and 4 pole - 50 Hz

SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 and 4 pole - 50 Hz OPERATING LIMITS Flow rates up to: 24 m 3 /h Head up to: Maximum immersion depth: 62 m 12.5 m Max. particle size: Ø 5 to 8* ND discharge port: 8/1 mm IP : 68 *depending on model UVO-UCA-UCB JETSON SUBMERSIBLE

More information

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel

TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : deltadore@deltadore.com Unit compliant with the requirements of directives:

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

Smoke Master JMHT HATCH Installation, operation and maintenance 10/2010

Smoke Master JMHT HATCH Installation, operation and maintenance 10/2010 Smoke Master JMHT HATCH Installation, operation and maintenance 10/2010 INSTALLATION, OPERATION AND MAINTENANCE Contents Table of contents...2 Safety aspects...3 System overview...3 Installation...4 Electrical

More information

Differential pressure sensors

Differential pressure sensors 1 923 1923P01 Differential pressure sensors for neutral or slightly aggressive gases and liquids QBE61.3-DP.. Operating voltage AC 24 V or DC 18...33 V Output signal DC 0...10 V Connecting male thread

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.1 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm Features Very short control times Low noise Mounting

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Mig C280 PRO, Mig C340 PRO. Spare parts list. Edition Valid for serial no. 627-xxx-xxxx, 119-xxx-xxxx,

Mig C280 PRO, Mig C340 PRO. Spare parts list. Edition Valid for serial no. 627-xxx-xxxx, 119-xxx-xxxx, Spare parts list Edition 20120710 Valid for serial no. 627-xxx-xxxx, 119-xxx-xxxx, Ordering no. Product 0349 302 889 Origo Mig C280 PRO 400-415 V, 3~50 Hz 0349 302 844 Origo Mig C280 PRO 230/400-415/415/500V,

More information

SUBMERSIBLE PUMPS AFP 0831 to 2046

SUBMERSIBLE PUMPS AFP 0831 to 2046 SUBMERSIBLE UMS AF 0831 to 046 DIN/EN 1050-1 Robust, reliable sewage pumps from 1.3 to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and communal areas.

More information

Air Cooler Industry AC-LN 8-14 MI with integrated frequency inverter

Air Cooler Industry AC-LN 8-14 MI with integrated frequency inverter Air Cooler Industry AC-LN 8-14 MI with integrated frequency inverter Symbol General The AC-LN MI air cooler series can be used in all areas where either oil or water-glycol has to be cooled with air. The

More information

33GS, 40GS, 55GS, 60GS, 75GS & 80GS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS

33GS, 40GS, 55GS, 60GS, 75GS & 80GS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS TECHNICAL BROCHURE B33-8GS R1 FEATURES Powered for Continuous Operation: All ratings are within the working limits of the motor as recommended by the motor manufacturer. can be operated continuously without

More information

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS SECTION 23 22 23 PART 1 GENERAL 1.1 DESCRIPTION A. Steam condensate pumps for Heating, Ventilating and Air Conditioning. B. Definitions: 1. Capacity: Liters per second (L/s) (Gallons per minute GPM) of

More information

Technical data sheet S_Series S_300 Vacuum pump systems

Technical data sheet S_Series S_300 Vacuum pump systems Technical data sheet S_Series S_300 Vacuum pump systems General information 2BL2 501-0K Standard version for use in general industries 2BL2 501-0H version with external two-chamber preseparator with automatic

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION

More information

Mirage over door heater. Features: Electric and LPHW versions. Compact and Versatile. Suitable for mounting up to 3.0m high from finished floor level.

Mirage over door heater. Features: Electric and LPHW versions. Compact and Versatile. Suitable for mounting up to 3.0m high from finished floor level. Features: Electric and LPHW versions. Compact and Versatile Suitable for mounting up to 3.0m high from finished floor level. Recessed or surface mounted. Energy saving controls option available. Available

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

CR3-21 A-FGJ-A-E-HQQE 3x400D 50HZ

CR3-21 A-FGJ-A-E-HQQE 3x400D 50HZ GRUNDFOS DATA BOOKLET CR3-21 A-FGJ-A-E-HQQE 3x4D 5HZ Grundfos Pump 96513345 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96513345/cr-3-21-a-fgj-a-e-hqqe.html

More information

inplan Thermal Oil Boilers have been proven for many years by successful installation in more than 30 countries.

inplan Thermal Oil Boilers have been proven for many years by successful installation in more than 30 countries. established 1968 Thermal Oil Plants Top quality and sophisticated technology provide solutions for individual heating problems. inplan Thermal Oil Boiler alternatively of horizontal or vertical design

More information

FOR SALE: RECYCLING PLANT FOR. - Aluminum scrap - Light metals - WEEE - Mixed industrial waste BANO PREMAC 28-90 HYDRO. Single shaft shredder

FOR SALE: RECYCLING PLANT FOR. - Aluminum scrap - Light metals - WEEE - Mixed industrial waste BANO PREMAC 28-90 HYDRO. Single shaft shredder FOR SALE: RECYCLING PLANT FOR - Aluminum scrap - Light metals - WEEE - Mixed industrial waste BANO PREMAC 28-90 HYDRO Single shaft shredder Stationary, weight 40 ton Table of content Sale of BANO PREMAC

More information

Auto Reset Gas Solenoid Valves GV-VMR

Auto Reset Gas Solenoid Valves GV-VMR Page 1 of 5 Description The VMR type valve is a fast opening single-stage solenoid valve, normally closed. This type of device is suitable for air or gas blocking and releasing controls, required in gas

More information

Energy Distribution. Applications Low Voltage Systems E8/1. Energy Distribution Panels in Hazardous Areas of Zone 1 and Zone 2

Energy Distribution. Applications Low Voltage Systems E8/1. Energy Distribution Panels in Hazardous Areas of Zone 1 and Zone 2 Energy Distribution Panels in Hazardous Areas of Zone 1 and Zone 2 Circuit breakers up to 800 A Load break switch / Main switch Busbar systems for internal energy distribution Miniature circuit breakers,

More information

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They

More information

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8

More information

Engineers Specification Permanent Test & Exercise Load Bank

Engineers Specification Permanent Test & Exercise Load Bank 1 1. Generator Load Bank Provide a fan-cooled resistive load bank for permanent, on-site installation as a component of the emergency power system. The load bank is to be used for periodic, scheduled,

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

CR10-03 A-A-A-E-HQQE 3x230/400 50 HZ

CR10-03 A-A-A-E-HQQE 3x230/400 50 HZ GRUNDFOS DATA BOOKLET CR1-3 A-A-A-E-HQQE 3x23/4 5 HZ Grundfos Pump 965981 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/965981/cr-1-3-a-a-a-e-hqqe.html

More information

Air handling unit. REC Temovex 250S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 250S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 25S-EC-RS Experts on indoor climate in low-energy houses RT 25S-EC-RS REC Temovex 25S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost

More information

Single Room Heat Recovery Ventilation. Nano Air 50. Advantages Conformity Installation Description Range Technical details Remote control

Single Room Heat Recovery Ventilation. Nano Air 50. Advantages Conformity Installation Description Range Technical details Remote control Single Room Heat Recovery Ventilation Advantages Conformity Installation Description Range Technical details Remote control Remote control Conformity electrical safety. Advantages Plug & Play installation.

More information

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application 42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application MAXIMIZING PERFORMANCE, ENERGY SAVINGS & COMFORT MODEL NUMBER NOMENCLATURE 4 2 C E T 0 0 3 4 7 0 1 2 5 42 series CISB Code

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

DGPS / Genset general description. > Soundproof genset with automatic startup, control card allows automatic, manual or signal start-up

DGPS / Genset general description. > Soundproof genset with automatic startup, control card allows automatic, manual or signal start-up Measures: L : 2775 mm H : 1690 mm W: 1100 mm H Weight: 1800 kg W L Hz 50 Hz V 400/230 V Water cooled Diesel Illustrative image. 1500 r.p.m Soundproof CE Conformity 1 / Genset general description GENERAL

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

33LS, 40LS, 55LS, 60LS, 75LS & 80LS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS

33LS, 40LS, 55LS, 60LS, 75LS & 80LS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS TECHNICAL BROCHURE B33-8LS R1 FEATURES Powered for Continuous Operation: All ratings are within the working limits of the motor as recommended by the motor manufacturer. can be operated continuously without

More information

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10

More information

ITT. Goulds Pumps 33GS, 40GS, 55GS, 60GS, 75GS, 80GS. Engineered for life. Residential Water Systems. Features

ITT. Goulds Pumps 33GS, 40GS, 55GS, 60GS, 75GS, 80GS. Engineered for life. Residential Water Systems. Features ITT Goulds s 33GS, 4GS, 55GS, 6GS, 75GS, 8GS 6 Hz High Capacity 4" Submersible s Goulds s is a brand of ITT Residential and Commercial Water. www.goulds.com Engineered for life Features n Powered for Continuous

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

P 72 Control System. This generator set has been designed to meet ISO 8528 regulation.

P 72 Control System. This generator set has been designed to meet ISO 8528 regulation. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded.

Long-distance capacitive proximity sensor. Ordering Information EB-74. Sensors. Accessories (Order Separately) Mounting Brackets. Unshielded. Long-distance capacitive proximity sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets.

E2K-C. Long-distance Capacitive Proximity Sensor. Ordering Information. Sensors. Accessories (Order Separately) Mounting Brackets. Long-distance Capacitive Proximity Sensor Capacitive Proximity Sensor with Adjustable Sensitivity Detects both metallic and non-metallic objects (glass, lumber, water, oil, plastic, etc.) without direct

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by

More information

COMPENSATION OF REACTIVE INPUT POWER POWER CONSUMPTION

COMPENSATION OF REACTIVE INPUT POWER POWER CONSUMPTION ENSURE CONTINUITY OF POWER SUPPLY DATA SHEET HIGH EFFICIENCY WARRANTY COMPENSATION OF REACTIVE INPUT POWER HYBRID WORK POWER CONSUMPTION UPS from series are on-line (VFI) class devices, intended to work

More information