TeSys protection components Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

Size: px
Start display at page:

Download "TeSys protection components Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7"

Transcription

1 Presentation Thermal-magnetic motor circuit-breakers types GV2, GV and GV7 GV2-ME, GV2-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control and protection of motors, conforming to standards IEC and IEC Connection These circuit-breakers are designed for connection by screw clamp terminals. Circuit-breaker GV2-ME can be supplied with spring terminal connections. These ensure secure, permanent and durable clamping that is resistant to harsh environments, vibration and impact and is even more effective when conductors without cable ends are used. Each connection can take two independent conductors. GV2-ME with screw clamp connections Operation O I O I O 2 1 GV2-ME with spring terminal connections GV2-P GV2-ME GV-ME GV2-P GV7-R GV2-ME and GV-ME: Pushbutton control. Energisation is controlled manually by operating the Start button I 1. De-energisation is controlled manually by operating the Stop button O 2, or automatically by the thermal-magnetic protection elements or by a voltage trip attachment. Control is manual and local when the motor circuit-breaker is used on its own. Control is automatic and remote when it is associated with a contactor. Protection of motors and personnel GV2-P: control by rotary knob. GV7-R: control by rocker lever. Energisation is controlled manually by moving the knob or rocker lever to position I 1. De-energisation is controlled manually by moving the knob or rocker lever to position O 2. De-energisation due to a fault automatically places the knob or rocker lever in the Trip position. Re-energisation is possible only after having returned the knob or rocker switch to position O. GV-ME Motor protection is provided by the thermal-magnetic protection elements incorporated in the motor circuit-breaker. The magnetic elements (short-circuit protection) have a non-adjustable tripping threshold, which is equal to about 1 times the maximum setting current of the thermal trips. The thermal elements (overload protection) include automatic compensation for ambient temperature variations. The rated operational current of the motor is displayed by means of a graduated knob 4. Personnel protection is also provided. All live parts are protected against direct finger contact. The addition of an undervoltage trip allows the circuit-breaker to be de-energised in the event of an undervoltage condition. The user is therefore protected against sudden starting of the machine when normal voltage is restored, since the Start button I has to be pressed to restart the motor. With the addition of a shunt trip, de-energisation of the unit can be remotely controlled. The operators on both open-mounted and enclosed motor circuit-breakers can be locked in the Stop position O by up to padlocks. Because they are suitable for isolation, these circuit-breakers, in the open position, provide an adequate isolation distance and indicate the actual position of the moving contacts by the position of the operators. Special features These motor circuit-breakers are easily installed in any configuration thanks to their universal fixing arrangement: screw fixing or clip-on mounting on symmetrical, asymmetrical or combination rails. GV7-R pages /24 to /9 pages /64 to /69 pages /70 and /71 /6 Schneider Electric

2 Thermal-magnetic motor circuit-breakers types GV2-ME and GV2-P GV2-ME GV2-P GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping 50/60 Hz in category AC- of current 400/415 V 500 V 690 V thermal Id ± 20 % P Icu Ics P Icu Ics P Icu Ics trips (2) (2) (2) () kw ka kw ka kw ka A A GV2-ME ( ( GV2-ME ( ( GV2-ME ( ( 0.7 ( ( GV2-ME ( ( GV2-ME ( ( 0.55 ( ( GV2-ME ( ( 0.7 ( ( GV2-ME ( ( 0.55 ( ( 0.75 ( ( GV2-ME ( ( 1.1 ( ( GV2-ME ( ( 1.1 ( ( GV2-ME ( ( 1.5 ( ( GV2-ME ( ( 2.2 ( ( GV2-ME ( ( GV2-ME ( ( GV2-ME ( ( GV2-ME GV2-ME GV2-ME GV2-ME GV2-ME GV2-ME22 (4) GV2-ME GV2-P with rotary knob and screw clamp terminals Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping 50/60 Hz in category AC- of current 400/415 V 500 V 690 V thermal Id ± 20 % P Icu Ics P Icu Ics P Icu Ics trips (2) (2) (2) () kw ka kw ka kw ka A A GV2-P ( ( GV2-P ( ( GV2-P ( ( 0.7 ( ( GV2-P ( ( GV2-P ( ( 0.55 ( ( GV2-P ( ( 0.7 ( ( GV2-P ( ( 0.55 ( ( 0.75 ( ( GV2-P ( ( 1.1 ( ( GV2-P ( ( 1.1 ( ( GV2-P ( ( 1.5 ( ( GV2-P ( ( 2.2 ( ( GV2-P ( ( ( ( GV2-P ( ( GV2-P ( ( GV2-P ( ( GV2-P GV2-P GV2-P GV2-P GV2-P GV2-P Thermal magnetic circuit-breakers GV2-ME with built-in auxiliary contact block pages /24 to /9 Schneider Electric With instantaneous auxiliary contact block (composition, see page /15): - GV-AE1, add suffix AE1TQ to the motor circuit-breaker reference selected above. Example: GV2-ME01AE1TQ. - GV-AE11, add suffix AE11TQ to the motor circuit-breaker reference selected above. Example: GV2-ME01AE11TQ. - GV-AN11, add suffix AN11TQ to the motor circuit-breaker reference selected above. Example: GV2-ME01AN11TQ. These circuit-breakers with built-in contact block are sold in lots of 20 units in a single pack. (1) For purchase in bulk packs of GV2-ME, see page i/7. (2) As % of Icu. () For use of GV2-ME in an enclosure, see pages 5/46 and 5/47. (4) Maximum rating which can be mounted in enclosures GV2-MC or MP, please call our Customer information centre on ( > 100 ka. pages /64 to /66 page /70 /7

3 Thermal-magnetic motor circuit-breakers type GV2-ME Thermal magnetic circuit-breakers GV2-ME with spring terminal connections (1) Pushbutton control Standard power ratings Setting Magnetic Reference Weight of -phase motors range of tripping 50/60 Hz in category AC- thermal current 400/415 V 500 V trips Id ± 20 % P Icu Ics (2) P Icu Ics (2) kw ka kw ka A A GV2-ME GV2-ME// 0.06 ( ( GV2-ME ( ( GV2-ME ( ( GV2-ME ( ( 0.25 ( ( 0.7 ( ( GV2-ME ( ( 0.7 ( ( 0.7 ( ( GV2-ME ( ( 0.55 ( ( 0.75 ( ( 0.75 ( ( 1.1 ( ( GV2-ME ( ( 1.5 ( ( GV2-ME ( ( 2.2 ( ( 2.2 ( ( GV2-ME ( ( GV2-ME ( ( GV2-ME GV2-ME GV2-ME GV2-ME Contact blocks Description Mounting Max. Type of contacts Sold in Unit Weight number lots of reference Instantaneous Front 1 N/O + N/C 10 GV-AE auxiliary N/O + N/O 10 GV-AE contacts LH 2 N/O + N/C 1 GV-AN side N/O + N/O 1 GV-AN Accessory Description Application Sold in Unit Weight lots of reference LA9-D99 Cable end For connection of 20 LA9-D99 reducer () conductors from 1 to 1.5 mm 2 (1) For connection of conductors from 1 to 1.5 mm 2 the use of a cable end reducer LA9-D99 is recommended. (2) As % of Icu. ( > 100 ka () 2 supplied with each circuit-breaker as standard. pages /24 to /9 pages /64 to /66 page /70 /8 Schneider Electric

4 Thermal-magnetic motor circuit-breakers type GV-ME Thermal magnetic circuit-breakers GV-ME with screw clamp terminals Pushbutton control Standard power ratings of -phase Setting range Reference Weight motors 50/60 Hz in category AC- of thermal 400/415 V 500 V 660/690 V trips P Icu Ics (1) P Icu Ics (1) P Icu Ics (1) kw ka kw ka kw ka A GV-ME GV-ME GV-ME GV-ME GV-ME GV-ME GV-ME GV-ME GV-ME40 (2) GV-ME6 (2) GV-ME80 (2) (1) As % of Icu. (2) Recommended for use in association with a contactor. pages /24 to /9 page /67 page /71 Schneider Electric /9

5 Thermal-magnetic motor circuit-breakers type GV7-R Thermal magnetic circuit-breakers GV7-R with screw clamp terminals Control by rocker lever Standard power ratings of -phase Setting range Reference Weight motors 50/60 Hz in category AC- of thermal 400/415 V 500 V 660/690 V trips P Icu Ics(1)P Icu Ics(1)P Icu Ics (1) kw ka kw ka kw ka A GV7-RE GV7-RE GV7-RS GV7-RE GV7-RS GV7-RE GV7-RS GV7-RS GV7-RE GV7-RS GV7-RE GV7-RS GV7-RE GV7-RS GV7-RE GV7-RS GV7-RE GV7-RS (1) As % of Icu. pages /24 to /9 page /67 page /71 /10 Schneider Electric

6 Thermal magnetic circuit-breakers type GV2-RT For motors with high current peak on starting GV2-RT Control by rocker lever Standard power ratings Setting Magnetic Reference Weight of -phase motors range of tripping 50/60 Hz in category AC- thermal current trips Id ± 20 % 20 V 415 V 440 V 500 V 690 V kw kw kw kw kw A A GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT For primaries of -phase transformers Control by rocker lever Standard power ratings Setting range Magnetic Reference Weight of thermal tripping current 240 V 415 V 440 V 500 V 690 V trips Id ± 20 % kva kva kva kva kva A A GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT GV2-RT Accessory (1) Description Reference Weight Padlockable external operator (IP 54), GV2-AP black handle, blue legend plate (1) Other accessories such as mounting, cabling and marking accessories are identical to those used for GV2-ME motor circuit-breakers, see page /21. pages /24 to /9 page /66 page /70 Schneider Electric /11

7 Magnetic motor circuit-breakers types GV2-LE and GV2-L Magnetic circuit breakers GV2-LE and GV2-L with screw clamp terminals GV2-LE GV2-L GV2-LE: rocker lever, GV2-L: rotary handle Standard power ratings Magnetic Trip- Use in Reference Weight of -phase motors protection ping association 50/60 Hz in category AC- rating current with 400/415 V 500 V 690 V Id ± 20 % thermal P Icu Ics P Icu Ics P Icu Ics overload (1) (1) (1) relay kw ka kw ka kw ka A A 0.06 ( ( LR2-K002 GV2-LE ( ( LR2-K004 GV2-LE0 0.0 or LRD-0 GV2-L ( ( 0.7 ( ( LR2-K004 GV2-LE or LRD-04 GV2-L ( ( LR2-K005 GV2-LE or LRD-04 GV2-L ( ( 1 1 LR2-K005 GV2-LE or LRD-05 GV2-L ( ( 1 1 LR2-K006 GV2-LE or LRD-05 GV2-L ( ( 1 1 LR2-K006 GV2-LE or LRD-06 GV2-L ( ( 0.7 ( ( 1 1 LR2-K006 GV2-LE or LRD-05 GV2-L ( ( 0.55 ( ( 1.1 ( ( LR2-K007 GV2-LE ( ( 0.55 LRD-06 GV2-L ( ( LR2-K007 GV2-LE or LRD-06 GV2-L ( ( 1.1 ( ( LR2-K008 GV2-LE ( ( 1.1 ( ( LRD-07 GV2-L ( ( LR2-K008 GV2-LE or LRD-08 GV2-L ( ( 1.5 ( ( LR2-K010 GV2-LE ( ( 1.5 ( ( LRD-08 GV2-L ( ( 4 51 LR2-K012 GV2-LE or LRD-08 GV2-L ( ( LR2-K012 GV2-LE ( ( ( ( LRD-10 GV2-L ( ( LR2-K014 GV2-LE ( ( LRD-12 GV2-L ( ( LR2-K016 GV2-LE or LRD-14 GV2-L LRD-14 GV2-LE LRD-14 GV2-L LRD-16 GV2-LE LRD-16 GV2-L LR2-K021 GV2-LE LRD-16 GV2-L LRD-21 GV2-LE LRD-21 GV2-L LRD-22 GV2-LE LRD-22 GV2-L LRD-22 GV2-LE LRD-22 GV2-L LRD-2 GV2-LE LRD-2 GV2-L2 0.0 (1) As % of Icu. ( > 100 ka. pages /0 to /9 pages /72 to /74 page /75 /12 Schneider Electric

8 Magnetic motor circuit-breakers type GK Magnetic circuit breakers GK with screw clamp terminals Rotary handle Standard power ratings Associated equipment Circuit-breakers of -phase motors Contactor Thermal Short-circuit 50/60 Hz in category AC- minimum overload protection size relay 400/415 V 500 V 690 V P Icu Ics P Icu Ics P Icu Ics Reference Reference Rat- Reference Weight (1) (1) (1) LC1- LRD- ing (1) kw ka kw ka kw ka A D GK-EF GK-EF D GK-EF D GK-EF D GK-EF D GK-EF D GK-EF D GK-EF D GK-EF D GK-EF D GK-EF (1) Associated current limiter or fuses, where required. See characteristics page /. pages /0 to /9 page /74 page /75 Schneider Electric /1

9 GV2-AK00 GV1-L GV-AX GV2-ME GV-AD GV-AM11 GV-AU GV2-P GV-AM11 GV-AS GV2-L GV-AE11, AE20 GV-AN GV-AN GV-AE1 GV2-LE GV-AE1 G SS Q /14 Schneider Electric

10 Thermal-magnetic and magnetic motor circuit-breakers type GV2 with screw clamp terminals Accessories Contact blocks with screw clamp terminals Description Mounting Maximum Type of contacts Sold in Unit Weight number lots of reference Instantaneous Front (1) 1 N/O or N/C (2) 10 GV-AE auxiliary N/O + N/C 10 GV-AE contacts N/O + N/O 10 GV-AE Side 2 N/O + N/C 1 GV-AN (LH) N/O + N/O 1 GV-AN Fault signalling Side () 1 N/O + N/O 1 GV-AD contact + (LH) (fault) + N/C 1 GV-AD instantaneous N/C + N/O 1 GV-AD auxiliary contact (fault) + N/C 1 GV-AD Short-circuit signalling Side 1 C/O 1 GV-AM contact (LH) common point Electric trips with screw clamp terminals Mounting Voltage Reference Weight Undervoltage or shunt trips (4) Side 24 V 50 Hz GV-A/ (1 block on RH side 60 Hz GV-A/ of circuit-breaker) 48 V 50 Hz GV-A/ Hz GV-A/ V 50 Hz GV-A/ V 60 Hz GV-A/ V 50 Hz GV-A/ Hz GV-A/ V 50 Hz GV-A/ V 60 Hz GV-A/ V 50 Hz GV-A/ V 220 V 60 Hz GV-A/ V 240 V 50 Hz GV-A/ Hz GV-A/ V 400 V 50 Hz GV-A/ Hz GV-A/ V 440 V 50 Hz GV-A/ V 60 Hz GV-A/ V 60 Hz GV-A/ V 60 Hz GV-A/ V 50 Hz GV-A/ V 60 Hz GV-A/ Undervoltage trip, INRS (can only be mounted on GV2-ME) Safety device for dangerous machines, conforming to INRS and VDE 011 Side V 50 Hz GV-AX (1 block on RH side 60 Hz GV-AX of circuit-breaker 127 V 60 Hz GV-AX GV2-ME) V 50 Hz GV-AX Hz GV-AX V 50 Hz GV-AX Hz GV-AX V 50 Hz GV-AX V 60 Hz GV-AX Add-on contact blocks with screw clamp terminals Description Mounting Maximum Reference Weight number LA9-LB920 pages /4, /8 & /9 Schneider Electric Visible isolation Front (1) 1 GV2-AK block (5) Limiters At top 1 GV1-L 0.10 (GV2-ME and GV2-P) Independent 1 LA9-LB (1) Mounting of a GV-AE contact block or a GV2-AK00 visible isolation block on GV2-P and GV2-L. (2) Choice of N/C or N/O contact operation, depending on which way round the reversible block is mounted. () The GV-AD is always mounted next to the circuit-breaker. (4) To order an undervoltage trip: replace the dot (/) in the reference with a U, example: GV-AU025. To order a shunt trip: replace the dot (/) in the reference with an S, example: GV-AS025. (5) Visible isolation of the poles upstream of circuit-breaker GV2-P and GV2-L. Dimensions and schemes: pages /64 to /75 /15

11 GV-A01...A07 GV-A08 GV-A09 /16 Schneider Electric

12 Motor circuit-breakers: thermal-magnetic type GV-ME and magnetic type GK with screw clamp terminals Accessories For thermal-magnetic circuit-breakers GV-ME Contact blocks Description Type of standard Reference Weight early break contacts Instantaneous auxiliary N/C + N/O GV-A contact blocks (1 per circuit-breaker) N/O + N/O GV-A N/C + N/O + N/O GV-A N/O + N/O + N/O GV-A N/O + N/O + 2 volt-free terminals GV-A N/C + N/O + 2 volt-free terminals GV-A Fault signalling N/C GV-A contacts (1) N/O GV-A Electric trips Description Voltages Reference Weight 50 Hz 60 Hz Undervoltage trips (1) 110, 120, 127 V 120, 127 V GV-B , 240 V 240, 277 V GV-B , 415 V 480 V GV-B Shunt trips (1) 110, 120, 127 V 120, 127 V GV-D , 240 V 240, 277 V GV-D , 415 V 480 V GV-D Accessory Description Sold in Unit Weight lots of reference Padlocking device, for locking 5 GV1-V the start button (on open-mounted product) For magnetic circuit-breakers GK Contact blocks Description Composition Reference Weight Auxiliary contact blocks for On-Off signalling and N/O GK2-AX control circuit test function (1 or 2 blocks per device) N/O + N/O GK2-AX mounted on RH side of GK-EF N/C + N/O GK2-AX Instantaneous fault signalling contact blocks N/O GK2-AX (1 or 2 blocks per device) N/O + N/O GK2-AX mounted on LH side of GK-EF N/C + N/O GK2-AX Accessories Description Reference Weight Padlocking device GK-AV for padlocking the operator, using up to padlocks (padlocks to be ordered separately) External operator GK-AP for mounting on the enclosure door. Red Ø 40 pushbutton on yellow plate. Can be locked in position O by means of up to padlocks, with door locked in position I and door locked in position O when padlocked. (1) 1 voltage trip OR 1 fault signalling contact to be fitted inside the motor circuit-breaker. pages /5 and /8 Other versions Dimensions and schemes: pages /64 to /75 24 to 690 V 50 or 60 Hz voltage trips for circuit-breakers GV-ME. Please call our Customer information centre on Schneider Electric /17

13 1 2 4 GV7-AE11, AB11 GV7-RE, RS GV7-AU, AS /18 Schneider Electric

14 Thermal-magnetic motor circuit-breakers type GV7-R with screw clamp terminals Accessories Add-on auxiliary contact blocks They allow remote indication of the circuit-breaker contact states. They can be used for signalling, electrical locking, relaying, etc. Two versions are available: standard and low level. They include a terminal block and the auxiliary circuits leave the circuit-breaker through a hole provided for this purpose. They perform the following functions, depending on where they are located in the circuit-breaker: Location Function Application 1 and/or 4 C/O contact Indicates the position of the circuit-breaker poles 2 Trip indication Indicates that the circuit-breaker has tripped due to an overload, a short-circuit, a differential faul or the operation of a voltage trip (undervoltage or shunt trip or of the push to trip test button. It resets when the circuit-break is reset. Electrical fault Indicates that the circuit-breaker has tripped due to an overload, a short-circuit or indication a differential fault. It resets when the circuit-breaker is reset. Type Reference Weight Standard GV7-AE Low level GV7-AB Fault discrimination devices They make it possible to: - either differentiate a thermal fault from a magnetic fault, - or open the contactor only in the event of a thermal fault. Voltage Reference Weight " and $ V GV7-AD111 (1) V GV7-AD112 (1) Electric trips These allow the circuit-breaker to be tripped via an electrical control signal. / Undervoltage trip GV7-AU - Trips the circuit-breaker when the control voltage drops below the tripping threshold, which is between 0.5 and 0.7 times the rated voltage. - Circuit-breaker closing is only possible if the voltage exceeds 0.85 times the rated voltage. Circuit-breaker tripping by a GV7-AU trip meets the requirements of IEC / Shunt trip GV7-AS Trips the circuit-breaker when the control voltage rises above 0.7 times the rated voltage. / Operation (GV7-AU or GV7-AS) - When the circuit-breaker has been tripped by a GV7-AU or AS, it must be reset either locally or by remote control. (For remote control, please call our Customer information centre on ). - Tripping has priority over manual closing: if a tripping instruction is present, manual action does not result in closing, even temporarily, of the contacts. - Durability: 50 % of the mechanical life of the circuit-breaker. Type Voltage Reference Weight Undervoltage 48 V, 50/60 Hz GV7-AU055 (1) trip V, 50/60 Hz GV7-AU107 (1) V, 50/60 Hz GV7-AU207 (1) V, 50/60 Hz GV7-AU87 (1) V, 50 Hz GV7-AU525 (1) pages /4 to /9 Schneider Electric Shunt 48 V, 50/60 Hz GV7-AS055 (1) trip V, 50/60 Hz GV7-AS107 (1) V, 50/60 Hz GV7-AS207 (1) V, 50/60 Hz GV7-AS87 (1) V, 50 Hz GV7-AS525 (1) (1) For mounting of a GV7-AD or a GV7-AU or AS. pages /67 to /69 page /71 /19

15 GV2-G454 GV2-G254 LAD-1 GV1-G09 GV2-G454 LAD-1 GV2-G254 GV1-G10 GV2-G05 LA9-E07 GV2-AF GV2-AF01 GV2-AF4 GK2-AF01 GV2-GA01 GV2-AF02 GV1-G02 GV2-AP0 2 TRIP. RESET GV2-V0 O /20 Schneider Electric

16 Thermal-magnetic and magnetic motor circuit-breakers type GV2 with screw clamp terminals Accessories Accessories Description Application Sold in Unit Weight lots of reference Adapter plate For mounting a GV2-ME 10 GV2-AF or GV2-LE by screw fixing For mounting a GV2-ME or 10 LAD GV2-P and contactor LC1-D09 to D8 with front faces aligned Height compensation plate 7.5 mm 10 GV1-F Combination block Between GV2 and contactor 10 GV2-AF LC1-K or LP1-K Between GV2 and contactor 10 GV2-AF LC1-D09 D8 Between GV2 mounted 10 GV2-AF on LAD-1 and contactor LC1-D09 D8 Motor starter With -pole connection 1 GK2-AF adapter plate for mounting a GV2 and an LC1-D09 to D25 contactor Description Application Pitch Reference Weight mm Sets of -pole 2 tap-offs 45 GV2-G A busbars 54 GV2-G GV2-G tap-offs 45 GV2-G GV2-G tap-offs 45 GV2-G GV2-G GV2-G tap-offs 54 GV2-G Description Application Sold in Unit Weight lots of reference Protective end cover (1) For unused busbar outlets 5 GV1-G Terminal blocks for Connection from the top 1 GV1-G supply to one or more Can be fitted with current limiter 1 GV2-G GV2-G busbar sets GV1-L (GV2-ME and GV2-P) Cover for terminal block For mounting in 10 LA9-E modular panels Flexible -pole connection Centre distance between 10 GV1-G for connecting a GV2 mounting rails: mm to an LC1-D09 D25 contactor Set of connections For connecting GV2-ME 10 GV2-GA upstream/downstream to a printed circuit board Clip-in marker holders For GV2-P, GV2-L, GV2-LE 100 LA9-D92 (1) (supplied with each and GV2-RT (8 x 22 mm) circuit-breaker) Padlockable external operator Description Reference Weight pages /64 to /74 Schneider Electric For GV2-P and GV2-L Padlocking in On and Off position GV2-AP (150 to 290 mm) Black handle, blue legend plate, IP 54 Padlocking in Off position GV2-AP Red handle, yellow legend plate, IP 54 For GV2-LE Padlocking in On and Off position GV2-AP Black handle, blue legend plate, IP 54 Padlocking device For all GV2 devices For use with up to 6 padlocks (not supplied), GV2-V Ø 6 mm shank max. (1) Check with requirements of local Isolation standards before use. /21

17 ON ON O OFF GV7AP04 O OFF ON GV7AP01, AP02 GV7RE, RS O OFF ON GV7AP0 ON O OFF ON O OFF GV7AP05 O OFF GV7AC04 GV7AC01 GV7V01 GV7RE, RS GV7-AC04 GV7AC0 GV7AC01 /22 Schneider Electric

18 Thermal-magnetic motor circuit-breakers type GV7-R with screw clamp terminals Accessories Cabling accessories Description Application For Sold Unit Weight contactor in reference lots of Clip-on Up to 150 A, mm 2 GV7-AC connectors for GV7-R Up to 220 A, mm 2 GV7-AC pole To increase the 1 GV7-AC spreader (1) pitch to 45 mm Terminal shields Supplied with the 1 GV7-AC IP 405 (1) sealing accessory Phase Safety accessories used 2 GV7-AC barriers when fitting of shields is impossible Insulating screens Ensure insulation between 2 GV7-AC the connections and the backplate Kit for combination Allowing link between the LC1-F115 1 GV7-AC with contactor circuit-breaker and the to F185 (2) contactor. The cover provides protection against LC1F225 1 GV7-AC direct finger contact. and F265 Direct rotary handle LC1-D115 1 GV7-AC and D150 Replaces the circuit-breaker front cover; secured by screws. It includes a device for locking the circuit-breaker in the O (Off) position by means of up to padlocks with a shank diameter of 5 to 8 mm (padlocks not supplied). A conversion accessory allows the direct rotary handle to be mounted on the enclosure door. In this case, the door cannot be opened if the circuit-breaker is in the tripped position. Circuit-breaker closing is inhibited if the enclosure door is open Description Type Degree of Reference Weight protection Direct Black handle, black legend plate IP 40 GV7-AP rotary handle Red handle, yellow legend plate IP 40 GV7-AP Conversion For mounting direct rotary IP 4 GV7-AP accessory () handle on enclosure door Extended rotary handle Allows a circuit-breaker installed in the back of an enclosure to be operated from the front of the enclosure. It comprises: - a unit which screws onto the front cover of the circuit-breaker, - an assembly (handle and front plate) to be fitted on the enclosure door, - an extension shaft which must be adjusted (distance between the mounting surface and the door: 185 mm minimum, 600 mm maximum). It includes a device for locking the circuit-breaker in the O (Off) position by means of up to padlocks with shank diameter of 5 to 8 mm (padlocks not supplied). This prevents the enclosure door from being opened. Description Type Degree of Reference Weight protection Extended Black handle, black legend plate IP 55 GV7-AP rotary handle Red handle, yellow legend plate IP 55 GV7-AP Locking device Allows circuit-breakers not fitted with a rotary handle to be locked in the O (Off) position by means of up to padlocks with a shank diameter of 5 to 8 mm (padlocks not supplied). Description Application Reference Weight Locking device For circuit-breaker not fitted GV7-V with a rotary handle (1) Terminal shields cannot be used together with spreaders. (2) Le kit comprises links, a protective shield and a depth adjustable metal bracket for the breaker. () This conversion accessory makes it impossible to open the door if the device is closed and prevents the device from being closed if the door is open. pages /4 to /9 pages /67 to /69 page /71 Schneider Electric /2

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120 Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Control Panel Technical Guide

Control Panel Technical Guide Control Panel Technical Guide How to select the appropriate motor starters for your HVAC & R* equipments * Heating, Ventilation, Air conditioning & Refrigeration Many machines can be used in a HVAC&R installation

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

3RV Motor Starter Protectors up to 100 A

3RV Motor Starter Protectors up to 100 A General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Breaking and protection devices

Breaking and protection devices Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while

More information

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases. G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

know-how Giant in distributing electricity for industry Prisma GK

know-how Giant in distributing electricity for industry Prisma GK Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Securing your electrical installations Prisma,

Securing your electrical installations Prisma, Securing your electrical installations Prisma, an optimised solution for type tested low voltage switchboards up to 3200 A Table of contents Developing installation safety 4 Prisma P * Electrical switchboards

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

A sophisticated design for a demanding field. prima series

A sophisticated design for a demanding field. prima series A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally

More information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

ATS - Automatic Changeover

ATS - Automatic Changeover ATS - Automatic Changeover Manufacturers of Electrical Switchgear Choosing an Automatic Transfer System Switchgear Systems offer a variety of solutions for multiple supply switching needs. As well as our

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO) SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

Wiring diagrams. Compact NSX. Contents

Wiring diagrams. Compact NSX. Contents Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

THERMAL RELAYS, MOTORSTARTERS

THERMAL RELAYS, MOTORSTARTERS THERMAL RELAYS, MOTORSTARTERS MH mini thermal relay plugged version H0K thermal relay with adapter H0K thermal relay plugged version T I thermal relay plugged version H thermal relay with current transformer

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution Low voltage circuit breakers Susol LV circuit breakers Super Solution Contents Overview Electrical characteristics Trip units Accessories

More information

Switchboard system. NorLine 800

Switchboard system. NorLine 800 Switchboard system NorLine 800 NorLine 800 SWITCHBOARD SYSTEM 2 NorLine 800 Switchboard system Table of contents Subject Page Table of contents 2 Overview 2-3 NorLine 800 technical specifications 4 Structural

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) 4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M Tested, certified, reliable Network monitoring and protection The electronic residual current

More information

MOTOR PROTECTIVE DEVICES

MOTOR PROTECTIVE DEVICES W MOTOR PROTECTIVE DEVICE, SERIES MP 206 BE400206 BE400306 Inherently stable without back-up fuseup to 4 A at 400 V AC, > 4 A main back-up fuse 100 A gl Thermal and magnetic release Terminal and accessory

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011

Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011 Low Voltage EasyPact CVS Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A Catalogue 2011 Safe Reliable Simple The easy choice for quality and value EasyPact CVS LV circuit breakers

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information