PHYS 3324 Experiment 2: Atomic Spectra

Size: px
Start display at page:

Download "PHYS 3324 Experiment 2: Atomic Spectra"

Transcription

1 PHYS 3324 Experiment 2: Atomic Spectra Background Reading: Krane, pp Apparatus: Spectrometer, sodium lamp, hydrogen lamp, mercury lamp, diffraction grating, watchmaker eyeglass, small flashlight. Prelab Questions: 1. What would be the diffraction angle, in first order, for a diffraction grating with a separation between rulings of 2 micrometers when observing the yellow sodium line? What would be the diffraction angle in second order? 2. Use the Rydberg-Ritz formula to calculate the wavelength for the n 2 = 3 to n 1 = 1 transition in hydrogen. Why can t this line be observed with the diffraction grating? I. Introduction Atomic spectra will be studied in this experiment using a diffraction grating mounted in a spectrometer. An atomic transition in sodium will be used to calibrate the line spacing of the grating, then the grating will be used to determine the Rydberg constant in hydrogen. II. Spectrometer A schematic drawing of the spectrometer is shown in Fig. 1. Light from the source enters the collimator tube through an adjustable slit and is formed into a parallel beam by the collimator lens. The beam enters the diffraction grating which produces sharp interference maxima at angles that are characteristic of the wavelengths of the incident light. Light from the diffraction grating then passes into a telescope. The objective lens and eyepiece of the telescope form an image which the observer aligns with a crosshair to measure the diffraction angle. The spectrometer is calibrated by using the two bright lines of sodium (sodium D lines). These two lines, with wavelengths = nm and nm, are so closely spaced that they can be regarded as one line with a wavelength of nm. 2-1

2 Figure 1. Spectrometer III. Diffraction Grating A diffraction grating is a sheet of celluloid which has a large number of evenly-spaced parallel lines ruled on it. The celluloid is sandwiched between glass plates. When parallel light is incident on such a grating, the light is diffracted with maxima at angles which satisfy the relation: d sin n (1) where d is the distance between successive rulings, is the wavelength of the incident light, and n is an integer called the order of the spectrum. This equation is derived in many elementary textbooks. Eq. 1 is not used directly in the experiment since it is difficult to align the diffraction grating exactly perpendicular to the light beam. It can be proved that, if the grating is misaligned, the diffraction maximum on one side of the beam, called n as in Fig. 2, is displaced nearly the same amount as the maximum on the other side, called. Therefore, if half the difference between these angles is used in Eq. 1, misalignment errors n 2-2

3 nearly cancel. Thus Eq. 1 becomes n d sin 2 n n (2) Figure 2. Diffracted beam from grating The spacing d is not known precisely for your grating. Therefore the spectrometer will be calibrated using a spectral line of known wavelength. Eq. 2 will be used in the form n sin 2 n Kn where the constant K=1/d is determined in the calibration procedure. (3) Note that it is necessary to measure a particular order of interference on both the left and right sides in order to use Eq. 3. Because most gratings do not produce equally intense light on both sides of the diffraction grating, some lines may be too weak to be seen on both sides in all orders. Such lines cannot be used. IV. Alignment The spectrometer has three components which must be aligned the collimator, the telescope and the grating. See Fig. 3 for the relative position of these elements. 2-3

4 The collimator is used to produce parallel rays from a source of light placed by its slit. It consists of a main tube, fitted at one end with an adjustable slit, and at the other, a small draw tube containing a lens. The draw tube may be slid in or out of the main tube, so as to place the slit in the focal plane of the lens. Figure 3. Spectrometer The telescope is used to receive parallel rays of light from the collimator after they have been diffracted by the grating mounted on the optical stage. It consists of a main tube which is fitted at one end with an objective lens. The other end holds a draw tube fitted with an eyepiece containing focusable cross hairs. The draw tube may be slid in or out of the main tube so as to focus the telescope at infinity, and the eyepiece may be slid in or out of the draw tube to bring the crosshairs into focus. The telescope may be rotated about the central axis of the instrument and then clamped into position. There is a fine motion tangent screw for precise positioning of the telescope. The rotation of the telescope is controlled by using a locking screw below the telescope. This screw should always be unlocked when rotating the telescope. When unlocked, the telescope will move freely using only slight pressure. The parts need not be forced to 2-4

5 move. A tangent screw next to the locking screw is used for fine adjustments after the locking screw is tightened. The diffraction grating is supported by an optical stage which has an adjustable vertical position and can be rotated. The locking screw just below the grating should be loosened before the grating is rotated. The optical-stage locking screw at the base of the spectrometer (see Fig. 3) should be locked. It is not used in this experiment. The face of the diffraction grating is delicate and should not be touched. If you must handle the grating, hold it by the edges. Turn on the sodium lamp and let it warm up as you do the steps below. It needs about 10 minutes to get warmed up to stable operating conditions. The following steps will align the spectrometer: A. Telescope Rotate the eyepiece in the telescope clockwise and move in or out to obtain a sharp image of the crosshair. Rotate the eyepiece until one of the crosshairs is parallel to the plane of the rotation of the telescope. The other cross hair will then be vertical if the spectrometer is in a horizontal plane. If the spectrometer is not in a horizontal plane, see your lab instructor. Loosen lock #1 in Fig. 1 (just below the grating) and carefully lift and remove the grating platform. Rotate the telescope so that it points at a distant object such as a wall. With Adj. A shown in Fig. 1, focus the telescope so that the image of the wall coincides with the crosshairs. The position of the telescope objective lens (Adj. A) should not be changed during the rest of the experiment once this condition has been attained. However, the eyepiece can be readjusted if a different observer is to use the spectrometer. B. Collimator Subdue ambient lighting if necessary. Widen the slit on the collimator to about 0.5 millimeter by using knob Adj. C in Fig. 1. Swing the telescope out of the way and look through the collimator to observe the slit image of the source. Center the sodium source in front of the collimator to get the maximum intensity for the slit image. 2-5

6 Unlock the telescope, if necessary, and position it directly opposite the collimator so as to be able to view the image of the slit. Lock the telescope in place. Using metal knob Adj. B, slide the draw tube of the collimator in or out until the slit is seen in focus, with sharp edges and exhibiting no parallax in relation to the crosshairs. If the slit is not parallel to the vertical cross hair, loosen the locking ring at the slit and rotate the slit for parallel alignment with the crosshair. Then use the locking ring to clamp the slit in place. The collimator is now adjusted. C. Diffraction grating With knob #1 loosened, replace the optical stage with the grating aligned perpendicular to the collimator, as determined by eye. The mount should be rotated so that the grating is between its support and the telescope. Tighten knob #1. V. Apparatus Carry out the following preliminary operations to familiarize yourself with the spectrometer. Use a sodium lamp as the light source and set the telescope directly in line with the collimator so that you can see the image of the slit as a vertical yellow line. This is the zero order. Try adjusting the width of the slit by turning the small screw (Adj. C) at the outer end of the collimator. It is easier to work with a wider slit when looking for images and then narrow it down for accurate location and measurement. Observe that the telescope arm can be rotated around the grating table which is calibrated in degrees. A vernier scale moving with the telescope will allow readings to ± 1 minute. There is a clamping screw beneath the telescope and a fine adjustment screw at the side, which only operates when the telescope is locked. The fine adjustment screw allows the cross hair to be accurately located on the line to be measured. VI. Calibration of grating 1. Rotate the telescope so that it looks directly into the collimator at the image of the slit. Observe the central band (n = 0, zero order) slit image and reduce the slit width to form a thin bright image that can be easily observed. 2-6

7 2. Move the telescope arm to align the slit image with the vertical cross-hair. Lock the telescope in place with the locking screw, then use the tangent screw for fine adjustment of the crosshair. 3. Read the angular position of the telescope arm on the graduated scale; you will need the watchmaker eyeglass for this reading. Note that this reading is obtained from a vernier scale and can be measured to an accuracy of one minute of arc. Some sample vernier scale readings are presented in Fig. 4. Figure 4. Two examples of how to read the vernier scale Record the uncertainty with which the angular position can be measured. (Note that this uncertainty may be dominated by your ability to set the crosshair at the center of the finite width line, and not necessarily by your random reading error on the finest division of the vernier scale.) 4. Now place your eye to the right of the telescope and, looking into the diffraction grating, move back and forth to see the first order (n = 1) image of the slit. 5. Measure the first order diffraction angle by loosening the locking screw on the telescope and swing it to the right. An easy way to do this is to first swing your head over until you see the spectrum, then, without moving your head, swing the telescope in front of your eye. 2-7

8 6. Once again lock the telescope in place and use the tangent screw to align the crosshair with the center of the image. Read the angular position and record this measurement as the right side, first order (n = 1) angular position Now place your eye to the left of the central (n = 0) position and look for the first order (n = 1) image. Measure this angle and record it as the left side, first order (n = 1) angular position Use these angles and the wavelength of sodium (589.3 nm) to calculate K in Eq. 3 and, from K, the number of lines per cm on the diffraction grating. Check your result with the lab instructor before moving on. VII. Hydrogen Spectrum Turn off the sodium lamp and turn on the hydrogren lamp as you read the setup directions below; the lamp needs about 10 minutes to be fully warmed up. The visible lines in the hydrogen spectrum are shown on a wall chart in the laboratory. There are four: one red, one blue-green and two violet. The second violet line is considerably weaker than the first; it may not be visible. 1. Replace the sodium calibration source with the hydrogen lamp. Bring the lamp as close to the slit as possible. Be careful not to disturb the alignment of the spectrometer. 2. Adjust the position of the source to give maximum brightness for the zero-order maximum. This is most easily done by swinging the telescope out of the way. 3. Measure the position of the telescope for each of the visible lines in the hydrogen spectrum in first order. Once again, open the slit as you move between lines or between orders and close it for the final measurement. Identify each angle to indicate the corresponding color. Remember that it is crucial to observe both positive and negative orders of interference. VIII. Mercury Spectrum Remove the hydrogen source and replace it with the mercury (Hg) source. Give the Hg lamp about 10 minutes to warm up before making your measurements. Look at the wall chart and pick out three mercury lines to measure. Locate these lines and measure them for both positive and negative orders of interference (in first order). IX. Report Your lab report should address all of the following points. 2-8

9 Introduction Describe how you calibrated the diffraction grating. Include your measurements and show how you calculated the constant K in Eq. 3. Use your error estimate on the angle reading () to make an error estimate on K. Use your value of K to determine the numbers of rulings per cm of the diffraction grating you used. Determine the wavelengths of all the visible lines of hydrogen by means of Eq. 3 and your measured angles. Show a sample calculation of how you obtain the wavelength from your measured data. You should also use your error estimate on the angle reading () and on K (K) along with the propagation of error formulae to determine the error on each of your wavelength determinations. Show a sample calculation of this. Include everything (angle measurements, calculated wavelengths and their errors) in a table. The Rydberg-Ritz formula for the wavelengths in the spectrum of atomic hydrogen is R 2 2 n1 n2 where n 1 =2 for the visible Balmer series and n 2 takes on positive integral values greater than 2. Using your measured values for, find by trial and error the proper values of n 2 and then solve for the Rydberg constant R. Determine the error on each of your determinations of R (from the error on the wavelength). Determine your final value of R (and its error) by computing the weighted average of your determinations of R. Compare with the accepted value of R = cm -1. Finally, draw an energy level diagram for the hydrogen atom and indicate the transitions that correspond to each of the lines you observed. Determine the wavelengths (and errors) of the Hg lines you measured and compare them to the accepted values you read from the wall chart in class. Summarize these results in a table. Conclusion 2-9

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

WAVELENGTH OF LIGHT - DIFFRACTION GRATING PURPOSE In this experiment we will use the diffraction grating and the spectrometer to measure wavelengths in the mercury spectrum. THEORY A diffraction grating is essentially a series of parallel equidistant

More information

THE BOHR QUANTUM MODEL

THE BOHR QUANTUM MODEL THE BOHR QUANTUM MODEL INTRODUCTION When light from a low-pressure gas is subject to an electric discharge, a discrete line spectrum is emitted. When light from such a low-pressure gas is examined with

More information

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block. 1 ATOMIC SPECTRA Objective: To measure the wavelengths of visible light emitted by atomic hydrogen and verify the measured wavelengths against those predicted by quantum theory. To identify an unknown

More information

GRID AND PRISM SPECTROMETERS

GRID AND PRISM SPECTROMETERS FYSA230/2 GRID AND PRISM SPECTROMETERS 1. Introduction Electromagnetic radiation (e.g. visible light) experiences reflection, refraction, interference and diffraction phenomena when entering and passing

More information

O6: The Diffraction Grating Spectrometer

O6: The Diffraction Grating Spectrometer 2B30: PRACTICAL ASTROPHYSICS FORMAL REPORT: O6: The Diffraction Grating Spectrometer Adam Hill Lab partner: G. Evans Tutor: Dr. Peter Storey 1 Abstract The calibration of a diffraction grating spectrometer

More information

Experiment #12: The Bohr Atom. Equipment: Spectroscope Hydrogen and Helium Gas Discharge Tubes, Holder, and Variac Flashlight

Experiment #12: The Bohr Atom. Equipment: Spectroscope Hydrogen and Helium Gas Discharge Tubes, Holder, and Variac Flashlight Experiment #12: The Bohr Atom Purpose: To observe the visible spectrum of hydrogen and helium and verify the Bohr model of the hydrogen atom. Equipment: Spectroscope Hydrogen and Helium Gas Discharge Tubes,

More information

Interference. Physics 102 Workshop #3. General Instructions

Interference. Physics 102 Workshop #3. General Instructions Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by

More information

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab EXPERIMENT O-6 Michelson Interferometer Abstract A Michelson interferometer, constructed by the student, is used to measure the wavelength of He-Ne laser light and the index of refraction of a flat transparent

More information

Solution Derivations for Capa #14

Solution Derivations for Capa #14 Solution Derivations for Capa #4 ) An image of the moon is focused onto a screen using a converging lens of focal length (f = 34.8 cm). The diameter of the moon is 3.48 0 6 m, and its mean distance from

More information

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,

More information

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory Physics 41, Winter 1998 Lab 1 - The Current Balance Theory Consider a point at a perpendicular distance d from a long straight wire carrying a current I as shown in figure 1. If the wire is very long compared

More information

!! Regarding the information about figures (Fig.XY) please have a look at the german version!! Spektroscopy

!! Regarding the information about figures (Fig.XY) please have a look at the german version!! Spektroscopy 1. Introduction (under construction) Spektroscopy 2. Prism and Grid Spectrometers Basics of Construction and Operation The experiment can be conducted with one of two types of spectrometer in which the

More information

FirstView 3 Reflector Telescope Owner s Manual

FirstView 3 Reflector Telescope Owner s Manual FirstView 3 Reflector Telescope Owner s Manual 1. Horizontal Locking Auxiliary Screw 2. Main Mount 3. Pitching Auxiliary Knob 4. Pitching Shaft Screw 5. Rack and Pinion Focusing Knob 6. Thumb Nut for Finder

More information

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LD Physics Leaflets P1.1.3.1.

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LD Physics Leaflets P1.1.3.1. Mechanics Measuring methods Determining the gravitational constant LD Physics Leaflets P1.1.3.1 Determining the gravitational constant with the gravitation torsion balance after Cavendish Measuring the

More information

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm? Test IV Name 1) In a single slit diffraction experiment, the width of the slit is 3.1 10-5 m and the distance from the slit to the screen is 2.2 m. If the beam of light of wavelength 600 nm passes through

More information

9/16 Optics 1 /11 GEOMETRIC OPTICS

9/16 Optics 1 /11 GEOMETRIC OPTICS 9/6 Optics / GEOMETRIC OPTICS PURPOSE: To review the basics of geometric optics and to observe the function of some simple and compound optical devices. APPARATUS: Optical bench, lenses, mirror, target

More information

Chapter 17: Light and Image Formation

Chapter 17: Light and Image Formation Chapter 17: Light and Image Formation 1. When light enters a medium with a higher index of refraction it is A. absorbed. B. bent away from the normal. C. bent towards from the normal. D. continues in the

More information

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1) Interferometers The true worth of an experimenter consists in his pursuing not only what he seeks in his experiment, but also what he did not seek. Claude Bernard (1813-1878) OBJECTIVES To examine the

More information

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours) INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as

More information

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Geometric Optics Converging Lenses and Mirrors Physics Lab IV Objective Geometric Optics Converging Lenses and Mirrors Physics Lab IV In this set of lab exercises, the basic properties geometric optics concerning converging lenses and mirrors will be explored. The

More information

Basic Optics System OS-8515C

Basic Optics System OS-8515C 40 50 30 60 20 70 10 80 0 90 80 10 20 70 T 30 60 40 50 50 40 60 30 C 70 20 80 10 90 90 0 80 10 70 20 60 50 40 30 Instruction Manual with Experiment Guide and Teachers Notes 012-09900B Basic Optics System

More information

Polarization of Light

Polarization of Light Polarization of Light References Halliday/Resnick/Walker Fundamentals of Physics, Chapter 33, 7 th ed. Wiley 005 PASCO EX997A and EX999 guide sheets (written by Ann Hanks) weight Exercises and weights

More information

Experiment IV: Atomic Spectra and the Bohr model

Experiment IV: Atomic Spectra and the Bohr model P19: INTRODUCTORY PHYSICS III Experiment IV: Atomic Spectra and the Bohr model Department of Physics and Astronomy Dartmouth College 6127 Wilder Laboratory Hanover, NH 03755 USA Overview In this lab, we

More information

CALIBRATION FOR LAL20X & LAL24X

CALIBRATION FOR LAL20X & LAL24X CALIBRATION AND FAULT FINDING FOR LAL20X & LAL24X DUMPY LEVELS MEASURING EXPERTS SINCE 1869 How The LAL20X & LAL24X Works The Automatic level is called Automatic because it requires only a simple basic

More information

Theremino System Theremino Spectrometer Technology

Theremino System Theremino Spectrometer Technology Theremino System Theremino Spectrometer Technology theremino System - Theremino Spectrometer Technology - August 15, 2014 - Page 1 Operation principles By placing a digital camera with a diffraction grating

More information

Care and Use of the Compound Microscope

Care and Use of the Compound Microscope Revised Fall 2011 Care and Use of the Compound Microscope Objectives After completing this lab students should be able to 1. properly clean and carry a compound and dissecting microscope. 2. focus a specimen

More information

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure The Microscope: A Tool of the Scientist You may refer to pages 66-67, 72-73 in your textbook for a general discussion of microscopes.

More information

Experiment 3 Lenses and Images

Experiment 3 Lenses and Images Experiment 3 Lenses and Images Who shall teach thee, unless it be thine own eyes? Euripides (480?-406? BC) OBJECTIVES To examine the nature and location of images formed by es. THEORY Lenses are frequently

More information

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages 291 294. Equipment Needed

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages 291 294. Equipment Needed Theory Refer to your Lab Manual, pages 291 294. Geometrical Optics Equipment Needed Light Source Ray Table and Base Three-surface Mirror Convex Lens Ruler Optics Bench Cylindrical Lens Concave Lens Rhombus

More information

1 Laboratory #5: Grating Spectrometer

1 Laboratory #5: Grating Spectrometer SIMG-215-20061: LABORATORY #5 1 Laboratory #5: Grating Spectrometer 1.1 Objective: To observe and measure the spectra of different light sources. 1.2 Materials: 1. OSA optics kit. 2. Nikon digital camera

More information

PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24

PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24 PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24 V112712 1 Collimation and Secondary Spacing Procedure The CDK optical design has four optical elements shown in Figure 1. The primary mirror

More information

Building your own Spectroscope

Building your own Spectroscope Building your own Spectroscope 0-0.341-0.445-0.606-0.872-1.36 Lyman Balmer Paschen n=4 n=8 n=7 n=6 n=5 n=4 ENERGY/10-19 J -2.42-5.45 E 5 2 E 4 2 E 3 2 E E 5 3 4 3 n=3 n=2 (Many other transitions beyond

More information

Diffraction of Laser Light

Diffraction of Laser Light Diffraction of Laser Light No Prelab Introduction The laser is a unique light source because its light is coherent and monochromatic. Coherent light is made up of waves, which are all in phase. Monochromatic

More information

Diffraction of a Circular Aperture

Diffraction of a Circular Aperture Diffraction of a Circular Aperture Diffraction can be understood by considering the wave nature of light. Huygen's principle, illustrated in the image below, states that each point on a propagating wavefront

More information

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = 3 + 4 = 9 + 16 = 25 or 2

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = 3 + 4 = 9 + 16 = 25 or 2 Forensic Spectral Anaylysis: Warm up! The study of triangles has been done since ancient times. Many of the early discoveries about triangles are still used today. We will only be concerned with the "right

More information

RAY OPTICS II 7.1 INTRODUCTION

RAY OPTICS II 7.1 INTRODUCTION 7 RAY OPTICS II 7.1 INTRODUCTION This chapter presents a discussion of more complicated issues in ray optics that builds on and extends the ideas presented in the last chapter (which you must read first!)

More information

Using light scattering method to find The surface tension of water

Using light scattering method to find The surface tension of water Experiment (8) Using light scattering method to find The surface tension of water The aim of work: The goals of this experiment are to confirm the relationship between angular frequency and wave vector

More information

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect Objectives: PS-7.1 Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect Illustrate ways that the energy of waves is transferred by interaction with

More information

1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical

More information

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012 Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012 Figure 1.1 illustrates the parts of an upright compound microscope and indicates the terminology that I use in these notes. Figure 1.1. Parts of a Compound

More information

Understanding astigmatism Spring 2003

Understanding astigmatism Spring 2003 MAS450/854 Understanding astigmatism Spring 2003 March 9th 2003 Introduction Spherical lens with no astigmatism Crossed cylindrical lenses with astigmatism Horizontal focus Vertical focus Plane of sharpest

More information

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope. MICROSCOPY I. OBJECTIVES To demonstrate skill in the proper utilization of a light microscope. To demonstrate skill in the use of ocular and stage micrometers for measurements of cell size. To recognize

More information

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator. PHYS 222 Spring 2012 Final Exam Closed books, notes, etc. No electronic device except a calculator. NAME: (all questions with equal weight) 1. If the distance between two point charges is tripled, the

More information

DIFFRACTION AND INTERFERENCE

DIFFRACTION AND INTERFERENCE DIFFRACTION AND INTERFERENCE In this experiment you will emonstrate the wave nature of light by investigating how it bens aroun eges an how it interferes constructively an estructively. You will observe

More information

E/M Experiment: Electrons in a Magnetic Field.

E/M Experiment: Electrons in a Magnetic Field. E/M Experiment: Electrons in a Magnetic Field. PRE-LAB You will be doing this experiment before we cover the relevant material in class. But there are only two fundamental concepts that you need to understand.

More information

Experiment #5: Qualitative Absorption Spectroscopy

Experiment #5: Qualitative Absorption Spectroscopy Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions

More information

PHYA2. General Certificate of Education Advanced Subsidiary Examination June 2010. Mechanics, Materials and Waves

PHYA2. General Certificate of Education Advanced Subsidiary Examination June 2010. Mechanics, Materials and Waves Centre Number Surname Candidate Number For Examiner s Use Other Names Candidate Signature Examiner s Initials Physics A Unit 2 For this paper you must have: a ruler a calculator a Data and Formulae Booklet.

More information

FORCE ON A CURRENT IN A MAGNETIC FIELD

FORCE ON A CURRENT IN A MAGNETIC FIELD 7/16 Force current 1/8 FORCE ON A CURRENT IN A MAGNETIC FIELD PURPOSE: To study the force exerted on an electric current by a magnetic field. BACKGROUND: When an electric charge moves with a velocity v

More information

PROFESSIONAL REFRACTOR MODEL 78-0040 25

PROFESSIONAL REFRACTOR MODEL 78-0040 25 30 0 30 60 90 1 2 3 4 PROFESSIONAL REFRACTOR MODEL 78-0040 25 24 22 21 20 19 5 9060 18 6 7 17 16 15 8 14 13 9 11 12 10 Figure 1 1. Objective Lens 2. Mounting Screws (2) 3. Declination Axis 4. Equatorial

More information

Collimation of an Alluna Ritchey-Chrétien telescope

Collimation of an Alluna Ritchey-Chrétien telescope Collimation of an Alluna Ritchey-Chrétien telescope This guide describes how to use your Alluna Ritchey Chrétien telescope in a few steps and adjust it perfectly in a matter of minutes. Collimation is

More information

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Measurement of Charge-to-Mass (e/m) Ratio for the Electron Measurement of Charge-to-Mass (e/m) Ratio for the Electron Experiment objectives: measure the ratio of the electron charge-to-mass ratio e/m by studying the electron trajectories in a uniform magnetic

More information

Diffraction and Young s Single Slit Experiment

Diffraction and Young s Single Slit Experiment Diffraction and Young s Single Slit Experiment Developers AB Overby Objectives Preparation Background The objectives of this experiment are to observe Fraunhofer, or far-field, diffraction through a single

More information

Instruction Manual Genesis 200 EQ

Instruction Manual Genesis 200 EQ Instruction Manual Genesis 200 EQ English version 8.2014 Rev A 1 The Zoomion Genesis 200 EQ Congratulations on the purchase of the new Zoomion Genesis 200 EQ. This advanced telescope will give you hours

More information

Alignement of a ring cavity laser

Alignement of a ring cavity laser Alignement of a ring cavity laser 1 Introduction This manual describes a procedure to align the cavity of our Ti:Sapphire ring laser and its injection with an Argon-Ion pump laser beam. The setup is shown

More information

(I) s(t) = s 0 v 0 (t t 0 ) + 1 2 a (t t 0) 2 (II). t 2 = t 0 + 2 v 0. At the time. E kin = 1 2 m v2 = 1 2 m (a (t t 0) v 0 ) 2

(I) s(t) = s 0 v 0 (t t 0 ) + 1 2 a (t t 0) 2 (II). t 2 = t 0 + 2 v 0. At the time. E kin = 1 2 m v2 = 1 2 m (a (t t 0) v 0 ) 2 Mechanics Translational motions of a mass point One-dimensional motions on the linear air track LD Physics Leaflets P1.3.3.8 Uniformly accelerated motion with reversal of direction Recording and evaluating

More information

Experiment 5. Lasers and laser mode structure

Experiment 5. Lasers and laser mode structure Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,

More information

THE COMPOUND MICROSCOPE

THE COMPOUND MICROSCOPE THE COMPOUND MICROSCOPE In microbiology, the microscope plays an important role in allowing us to see tiny objects that are normally invisible to the naked eye. It is essential for students to learn how

More information

INDEX. SR NO NAME OF THE PRACTICALS Page No. Measuring the bearing of traverse lines, calculation of included angles and check.

INDEX. SR NO NAME OF THE PRACTICALS Page No. Measuring the bearing of traverse lines, calculation of included angles and check. INDEX SR NO NAME OF THE PRACTICALS Page No 1 Measuring the bearing of traverse lines, calculation of included angles and check. 1 2 To study the essential parts of dumpy level & reduction of levels 3 To

More information

Pre-lab Quiz/PHYS 224 Magnetic Force and Current Balance. Your name Lab section

Pre-lab Quiz/PHYS 224 Magnetic Force and Current Balance. Your name Lab section Pre-lab Quiz/PHYS 224 Magnetic Force and Current Balance Your name Lab section 1. What do you investigate in this lab? 2. Two straight wires are in parallel and carry electric currents in opposite directions

More information

Refraction of Light at a Plane Surface. Object: To study the refraction of light from water into air, at a plane surface.

Refraction of Light at a Plane Surface. Object: To study the refraction of light from water into air, at a plane surface. Refraction of Light at a Plane Surface Object: To study the refraction of light from water into air, at a plane surface. Apparatus: Refraction tank, 6.3 V power supply. Theory: The travel of light waves

More information

Reflection and Refraction

Reflection and Refraction Equipment Reflection and Refraction Acrylic block set, plane-concave-convex universal mirror, cork board, cork board stand, pins, flashlight, protractor, ruler, mirror worksheet, rectangular block worksheet,

More information

Lesson 29: Lenses. Double Concave. Double Convex. Planoconcave. Planoconvex. Convex meniscus. Concave meniscus

Lesson 29: Lenses. Double Concave. Double Convex. Planoconcave. Planoconvex. Convex meniscus. Concave meniscus Lesson 29: Lenses Remembering the basics of mirrors puts you half ways towards fully understanding lenses as well. The same sort of rules apply, just with a few modifications. Keep in mind that for an

More information

Fraunhofer Diffraction

Fraunhofer Diffraction Physics 334 Spring 1 Purpose Fraunhofer Diffraction The experiment will test the theory of Fraunhofer diffraction at a single slit by comparing a careful measurement of the angular dependence of intensity

More information

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1 Chemistry 111 Lab: Intro to Spectrophotometry Page E-1 SPECTROPHOTOMETRY Absorption Measurements & their Application to Quantitative Analysis study of the interaction of light (or other electromagnetic

More information

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid Introduction Many metals react with acids to form hydrogen gas. In this experiment, you will use the reactions

More information

Blackbody Radiation References INTRODUCTION

Blackbody Radiation References INTRODUCTION Blackbody Radiation References 1) R.A. Serway, R.J. Beichner: Physics for Scientists and Engineers with Modern Physics, 5 th Edition, Vol. 2, Ch.40, Saunders College Publishing (A Division of Harcourt

More information

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object PHYS1000 Optics 1 Optics Light and its interaction with lenses and mirrors. We assume that we can ignore the wave properties of light. waves rays We represent the light as rays, and ignore diffraction.

More information

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES The purpose of this lab session is to experimentally investigate the relation between electric field lines of force and equipotential surfaces in two dimensions.

More information

Total Station Setup and Operation. Sokkia SET Total Station

Total Station Setup and Operation. Sokkia SET Total Station Total Station Setup and Operation Sokkia SET Total Station Parts of the SET Total Station Parts of the SET Total Station Sokkia SET 550 Total Station Keys/Screen SET 550 Menu Pages SET 550 Menu Pages Leveling

More information

Melting Point, Boiling Point, and Index of Refraction

Melting Point, Boiling Point, and Index of Refraction Melting Point, Boiling Point, and Index of Refraction Melting points, boiling points, and index of refractions are easily measured physical properties of organic compounds useful in product characterization

More information

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 ENG Instructions Thank you for purchasing a Canon product. Canon s TS-E lenses are tilt-shift lenses designed for EOS cameras. The tilt-shift mechanism enables

More information

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher) What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher) Introduction: There is more to a color than a name. Color can tell us lots of information. In this lab you will use a spectrophotometer

More information

Reading assignment: All students should read the Appendix about using oscilloscopes.

Reading assignment: All students should read the Appendix about using oscilloscopes. 10. A ircuits* Objective: To learn how to analyze current and voltage relationships in alternating current (a.c.) circuits. You will use the method of phasors, or the vector addition of rotating vectors

More information

Experiment 2 Index of refraction of an unknown liquid --- Abbe Refractometer

Experiment 2 Index of refraction of an unknown liquid --- Abbe Refractometer Experient Index of refraction of an unknown liquid --- Abbe Refractoeter Principle: The value n ay be written in the for sin ( δ +θ ) n =. θ sin This relation provides us with one or the standard ethods

More information

VISM Evolution Scope Series

VISM Evolution Scope Series 1 VISM Evolution Scope Series Congratulations on the purchase of your New VISM Evolution (EVO) Series Scope! The EVO Series of Scopes give you many great high end features and various magnification ranges

More information

Friday 18 January 2013 Morning

Friday 18 January 2013 Morning Friday 18 January 2013 Morning AS GCE PHYSICS B (ADVANCING PHYSICS) G492/01 Understanding Processes / Experimentation and Data Handling *G411640113* Candidates answer on the Question Paper. OCR supplied

More information

About Coffee and Refractometers 2008-2010 Voice Systems Technology, Inc. (VST)

About Coffee and Refractometers 2008-2010 Voice Systems Technology, Inc. (VST) About Coffee and Refractometers 2008-200 Voice Systems Technology, Inc. (VST) www.mojotogo.us.0 Coffee and Refractive Index Refractive Index measurements have been used for process control in the food

More information

Microscope Lab Introduction to the Microscope Lab Activity

Microscope Lab Introduction to the Microscope Lab Activity Microscope Lab Introduction to the Microscope Lab Activity Wendy Kim 3B 24 Sep 2010 http://www.mainsgate.com/spacebio/modules/gs_resource/ CellDivisionMetaphase.jpeg 1 Introduction Microscope is a tool

More information

Electric Field Mapping Lab 3. Precautions

Electric Field Mapping Lab 3. Precautions HB 09-25-07 Electric Field Mapping Lab 3 1 Electric Field Mapping Lab 3 Equipment mapping board, U-probe, resistive boards, templates, dc voltmeter (431B), 4 long leads, 16 V dc for wall strip Reading

More information

PHYSICS PAPER 1 (THEORY)

PHYSICS PAPER 1 (THEORY) PHYSICS PAPER 1 (THEORY) (Three hours) (Candidates are allowed additional 15 minutes for only reading the paper. They must NOT start writing during this time.) ---------------------------------------------------------------------------------------------------------------------

More information

Thin Lenses Drawing Ray Diagrams

Thin Lenses Drawing Ray Diagrams Drawing Ray Diagrams Fig. 1a Fig. 1b In this activity we explore how light refracts as it passes through a thin lens. Eyeglasses have been in use since the 13 th century. In 1610 Galileo used two lenses

More information

EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS

EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS The following website should be accessed before coming to class. Text reference: pp189-196 Optics Bench a) For convenience of discussion we assume that the light

More information

1 of 9 2/9/2010 3:38 PM

1 of 9 2/9/2010 3:38 PM 1 of 9 2/9/2010 3:38 PM Chapter 23 Homework Due: 8:00am on Monday, February 8, 2010 Note: To understand how points are awarded, read your instructor's Grading Policy. [Return to Standard Assignment View]

More information

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used. STAGE MICROMETERS Introduction Whenever there is a need to make measurements with an eyepiece graticule, there is also a need to ensure that the microscope is calibrated. The use of a stage micrometer

More information

Lenses and Telescopes

Lenses and Telescopes A. Using single lenses to form images Lenses and Telescopes The simplest variety of telescope uses a single lens. The image is formed at the focus of the telescope, which is simply the focal plane of the

More information

Calculating Astronomical Unit from Venus Transit

Calculating Astronomical Unit from Venus Transit Calculating Astronomical Unit from Venus Transit A) Background 1) Parallaxes of the Sun (the horizontal parallaxes) By definition the parallaxes of the Sun is the angle β shown below: By trigonometry,

More information

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY Adapted from Foundations of Biology I; Lab 6 Introduction to Microscopy Dr. John Robertson, Westminster College Biology Department,

More information

If you put the same book on a tilted surface the normal force will be less. The magnitude of the normal force will equal: N = W cos θ

If you put the same book on a tilted surface the normal force will be less. The magnitude of the normal force will equal: N = W cos θ Experiment 4 ormal and Frictional Forces Preparation Prepare for this week's quiz by reviewing last week's experiment Read this week's experiment and the section in your textbook dealing with normal forces

More information

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling

More information

DSV-2 ALTITUDE-AZIMUTH TELESCOPE MOUNT User Manual

DSV-2 ALTITUDE-AZIMUTH TELESCOPE MOUNT User Manual DSV-2 ALTITUDE-AZIMUTH TELESCOPE MOUNT User Manual Your New Mount Thanks for choosing the Desert Sky Astro Products DSV-2 mount. Take some time to familiarize yourself with its features (Figure 1). Please

More information

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up 2 Luxxor Video Microscope Set Up User Guide LUXXOR VIDEO MICROSCOPE Column When removed from its packaging, the Luxxor Video Microscope will be configured as shown, with the Vertical Slide and Slide Stop

More information

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment. Helium-Neon Laser Experiment objectives: assemble and align a 3-mW HeNe laser from readily available optical components, record photographically the transverse mode structure of the laser output beam,

More information

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law. 260 17-1 I. THEORY EXPERIMENT 17 QUALITATIVE STUDY OF INDUCED EMF Along the extended central axis of a bar magnet, the magnetic field vector B r, on the side nearer the North pole, points away from this

More information

How To Understand Light And Color

How To Understand Light And Color PRACTICE EXAM IV P202 SPRING 2004 1. In two separate double slit experiments, an interference pattern is observed on a screen. In the first experiment, violet light (λ = 754 nm) is used and a second-order

More information

Lesson 26: Reflection & Mirror Diagrams

Lesson 26: Reflection & Mirror Diagrams Lesson 26: Reflection & Mirror Diagrams The Law of Reflection There is nothing really mysterious about reflection, but some people try to make it more difficult than it really is. All EMR will reflect

More information

3 LEVELLING & SURVEYING

3 LEVELLING & SURVEYING 3 LEVELLING & SURVEYING 3.1 General The primary reference at water-level recording stations is a set of stable bench-marks, installed in locations where their level should not change. Upon initial set-up

More information

The DC Motor. Physics 1051 Laboratory #5 The DC Motor

The DC Motor. Physics 1051 Laboratory #5 The DC Motor The DC Motor Physics 1051 Laboratory #5 The DC Motor Contents Part I: Objective Part II: Introduction Magnetic Force Right Hand Rule Force on a Loop Magnetic Dipole Moment Torque Part II: Predictions Force

More information

Using an Abney Level to Measure Relative Heights

Using an Abney Level to Measure Relative Heights 1) Introduction Using an Abney Level to Measure Relative Heights An Abney level is a small surveying instrument that consists of a sighting tube and a spirit level linked to a protractor and this allows

More information

Optics. Kepler's telescope and Galileo's telescope. f 1. f 2. LD Physics Leaflets P5.1.4.2. Geometrical optics Optical instruments

Optics. Kepler's telescope and Galileo's telescope. f 1. f 2. LD Physics Leaflets P5.1.4.2. Geometrical optics Optical instruments Optics Geometrical optics Optical instruments LD Physics Lealets P5.1.4.2 Kepler's telescope and Galileo's telescope Objects o the experiment g Veriying that the length o a telescope is given by the sum

More information

BARREL ALIGNMENT- A CRITICAL FACTOR IN REDUCING EXTRUDER WEAR

BARREL ALIGNMENT- A CRITICAL FACTOR IN REDUCING EXTRUDER WEAR BARREL ALIGNMENT- A CRITICAL FACTOR IN REDUCING EXTRUDER WEAR Jeff A. Myers- BARR Inc., Onsted, MI Mike Puhalla Milacron, Batavia, OH Abstract As processors increase the demand on the extruder for increased

More information