COM Server Unit DXE421 USER'S GUIDE
|
|
- Loren Bridges
- 7 years ago
- Views:
Transcription
1 COM Server Unit DXE421 USER'S GUIDE M210608EN-A November 2004
2 PUBLISHED BY Vaisala Oyj Phone (int.): P.O. Box 26 Fax: FIN Helsinki Finland Visit our Internet pages at Vaisala 2004 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.
3 Table of Contents CHAPTER 1 GENERAL INFORMATION... 3 About This Manual... 3 Contents of This Manual... 3 Safety... 4 General Safety Considerations... 4 ESD Protection... 4 Warranty... 5 CHAPTER 2 PRODUCT OVERVIEW... 7 Introduction to DXE CHAPTER 3 OPERATION... 9 Installation... 9 Configuration Server Configuration Serial Port Configuration Standard Connection Modem Mode Connection Application, DXE421 and ROSA Connection to ROSA CHAPTER 4 CONTACT INFORMATION Technical Support Return Instructions CHAPTER 5 TECHNICAL DATA Specifications VAISALA 1
4 User's Guide List of Figures Figure 1 DXE421 COM Server Unit...7 Figure 2 DXE421 and Terminal...9 Figure 3 Standard Connection...13 Figure 4 Modem Mode Connection...14 Figure 5 Connection to ROSA...15 List of Tables Table 1 Power Input...19 Table 2 Serial RS-232 Interface...19 Table 3 Ethernet Interface...20 Table 4 Mechanical...20 Table 5 Environmental M210608EN-A
5 Chapter 1 General Information CHAPTER 1 GENERAL INFORMATION This chapter provides general notes for the product. About This Manual This manual provides information for installing and operating DXE421 Ethernet COM Server Unit. This manual introduces some application examples. For further information and detailed manual for the equipment, see the applicable manual at the following location: - Xport device server: Contents of This Manual This manual consists of the following chapters: - Chapter 1, General Information, provides general notes for the product. - Chapter 2, Product Overview, introduces the features, advantages of the product. - Chapter 3, Operation, contains information that is needed to operate this product. - Chapter 4, Contact Information, describes contact information. - Chapter 5, Technical Data, provides the tehcnical data of DXE421 COM Server Unit. VAISALA 3
6 User's Guide Safety General Safety Considerations Throughout the manual, important safety considerations are highlighted as follows: WARNING Warning alerts you to a serious hazard. If you do not read and follow instructions very carefully at this point, there is a risk of injury or even death. CAUTION Caution warns you of a potential hazard. If you do not read and follow instructions carefully at this point, the product could be damaged or important data could be lost. NOTE Note highlights important information on using the product. ESD Protection Electrostatic Discharge (ESD) can cause immediate or latent damage to electronic circuits. Vaisala products are adequately protected against ESD for their intended use. However, it is possible to damage the product by delivering electrostatic discharges when touching, removing, or inserting any objects inside the equipment housing. To make sure you are not delivering high static voltages yourself: - Handle ESD sensitive components on a properly grounded and protected ESD workbench. When this is not possible, ground yourself to the equipment chassis before touching the boards. Ground yourself with a wrist strap and a resistive connection cord. When neither of the above is possible, touch a conductive part of the equipment chassis with your other hand before touching the boards. - Always hold the boards by the edges and avoid touching the component contacts. 4 M210608EN-A
7 Chapter 1 General Information Warranty For certain products Vaisala normally gives a limited one-year warranty. Please observe that any such warranty may not be valid in case of damage due to normal wear and tear, exceptional operating conditions, negligent handling or installation, or unauthorized modifications. Please see the applicable supply contract or Conditions of Sale for details of the warranty for each product. VAISALA 5
8 User's Guide This page intentionally left blank. 6 M210608EN-A
9 Chapter 2 Product Overview CHAPTER 2 PRODUCT OVERVIEW This chapter introduces the features, advantages of the product. Introduction to DXE421 The DXE421 unit has a small enclosure of 20 mm x 80 mm x 76 mm with DIN rail mounting support that can be connected into various enclosures. The DXE421 has face connectors where the power supply, RS-232 and Ethernet line can be connected. See Figure 1 below. Figure DXE421 COM Server Unit The following numbers refer to Figure 1 above: 1 = Power input 2 = RS-232 interface 3 = Ethernet line interface VAISALA 7
10 User's Guide This page intentionally left blank. 8 M210608EN-A
11 Chapter 3 Operation CHAPTER 3 OPERATION This chapter contains information that is needed to operate this product. Installation Install DXE421 unit onto a DIN rail. Make sure that connection between the DIN rail and the grounding point is good. Figure 2 DXE421 and Terminal Connect the Ethernet line cable to DXE421 Ethernet interface RJ45 connector. Connect the serial cable between DXE421 and PC COM port or ROSA, MILOS, MAWS or etc. Connect the power to DXE421. Make sure that polarity of power cable is correct. The over-voltage, short-circuit and reverse connection protection are included in DXE421. VAISALA 9
12 User's Guide Configuration MAC address. The DXE421 unit's MAC address is on the product label. MAC address: a- - - IP address. The DXE421 unit must have a unique IP address on your network. The systems administrator provides the IP address and corresponding subnet mask and gateway. IP address: Subnet mask: Gateway: The recommended way to configure the DXE421 unit is to use a terminal program. The default serial line settings for DXE421 are: N 1. Connect the RS-232 serial cable between the DXE421 unit and the computer's serial port in accordance with Figure 2 on page 9. NOTE When initial configuration has been done and DXE421 is connected to the network, it is possible to make configurations through a Telnet connection. From the DOS prompt give the following command: C:\telnet xxx.xxx.xxx.xxx 9999 (where xxx is the IP number and 9999 is the port number.) The easiest way to enter the setup mode is to hold down the X key and switch on the power. The following text will appear on the screen: MAC address 00204A Software version 01.6 (040308) XPTE Press Enter to go into Setup Mode Press ENTER to proceed. 10 M210608EN-A
13 Chapter 3 Operation Server Configuration This section gives instructions on how server configuration of the DXE421 should be done. The following menu is displayed: Change Setup: 0 Server configuration 1 Channel 1 configuration 3 settings 5 Expert settings 6 Security 7 Factory defaults 8 Exit without save 9 Save and exit Your choice? 0 Choose 0 for server configuration and give the following IP settings in accordance with the provider information. IP Address : (172).(025).(010).(072) Set Gateway IP Address (Y) Y Gateway IP addr (172).(025).(000).(001) Netmask: Number of Bits for Host Part (0=default) (16) Change telnet config password (N) N Netmask is given in numbers of bits in the following way: equals equals equals 8 The Telnet password disallows configuration of DXE421 using Telnet through network without the correct password. It does not affect the serial line configuration. The password can be three letters long. Serial Port Configuration This section gives instructions on how the serial port from DXE421 should be configured. In the menu, select number 1. Change Setup: 0 Server configuration 1 Channel 1 configuration 3 settings VAISALA 11
14 User's Guide 5 Expert settings 6 Security 7 Factory defaults 8 Exit without save 9 Save and exit The following menu is displayed:. Baudrate (9600)? I/F Mode (4C)? Flow (00)? Port No (10001)? ConnectMode (C0)? Remote IP Address : (172).(025).(010).(052) Remote Port (10001)? DisConnMode (00)? FlushMode (00)? DisConnTime (00:00)?: SendChar 1 (00)? SendChar 2 (00)? Make the following selections: Baudrate: The default setting is The baudrate can be 300, 600, 1200, 2400, 4800, 9600, 19200, and I/F (Interface) mode: The default setting is 4C. 4C RS-232C, 8-bit, no parity, 1 stop bit 78 RS-232C, 7-bit, even parity, 1 Stop bit Flow control: The default setting is No flow control 01 XON/XOFF flow control 02 Hardware handshake with RTS/CTS lines 05 XON/XOFF pass characters to host Port number: The default setting for Port 1 is The port number identifies the channel for remote initiating connections. The range is except for reserved ports: Port no Reserved for Reserved (well known ports) 9999 Telnet setup Reserved for Redirector 12 M210608EN-A
15 Chapter 3 Operation Reserved (77F0h) Reserved (77FEh) Connect mode: The default setting is C0 (always accept incoming connection, no active startup). The connect mode defines the communication method used with DXE421. NOTE A DXE421 unit can be in C0 connect mode, no matter if the connection is made directly from the PC to Ethernet or from the PC via a serial port using the DXE421 unit to Ethernet. Figure 3 Standard Connection If a serial port from the computer side is used for communication to Ethernet (see Figure 4 on page 14), then select Modem mode, set the Connect mode to C6, D6 or D7. C6 No echo D6 Echo with full verbose D7 Echo with one character response This means that user can make a connection to the weather station over internet using any terminal program. This allows also remote software downloading to for example a ROSA station using the Iceterm program. VAISALA 13
16 User's Guide Figure 4 Modem Mode Connection Standard Connection From the PC the connection to the unit can be created by giving the following command from the DOS prompt: C:\Telnet xxx.xxx.xxx.xxx yyyyy Where xxx is the IP number and yyyyy is the defined port number. Modem Mode Connection If the connect mode has been set as modem mode (C6, D6,D7), the connection is made by sending the following command to the serial port using, for example, with a terminal program or some other polling program: ATDTxxx.xxx.xxx.xxx,yyyy Where xxx is the IP number and yyyy is the defined port number. Application, DXE421 and ROSA Open a terminal connection to ROSA and give the following settings: Set the baud rate for RS-232 line to 9600: BAUD RS Set the communication mode for plain RS-232: COM RS M210608EN-A
17 Chapter 3 Operation Connection to ROSA After the DXE421 configuration is completed, connect the unit to ROSA according to the Figure 5 below. Figure 5 Connection to ROSA VAISALA 15
18 User's Guide This page intentionally left blank. 16 M210608EN-A
19 Chapter 4 Contact Information CHAPTER 4 CONTACT INFORMATION This chapter describes contact information. Technical Support For technical questions, contact the Vaisala technical support: helpdesk@vaisala.com Phone (int.) Fax Return Instructions If the product needs repair, please follow the instructions below to speed up the process and avoid extra costs. 1. Read the warranty information. 2. Write a Problem Report with the name and contact information of a technically competent person who can provide further information on the problem. 3. On the Problem Report, please explain: - What failed (what worked / did not work)? - Where did it fail (location and environment)? - When did it fail (date, immediately / after a while / periodically / randomly)? - How many failed (only one defect / other same or similar defects / several failures in one unit)? VAISALA 17
20 User's Guide - What was connected to the product and to which connectors? - Input power source type, voltage and list of other items (lighting, heaters, motors etc.) that were connected to the same power output. - What was done when the failure was noticed? 4. Include a detailed return address with your preferred shipping method on the Problem Report. 5. Pack the faulty product using an ESD protection bag of good quality with proper cushioning material in a strong box of adequate size. Please include the Problem Report in the same box. 6. Send the box to: Vaisala Oyj Contact person / Division Vanha Nurmijärventie 21 FIN Vantaa Finland 18 M210608EN-A
21 Chapter 5 Technical Data CHAPTER 5 TECHNICAL DATA This chapter provides the technical data of DXE421 COM Server Unit. Specifications Table 1 Power Input Property Description / Value Supply voltage +5 to +30 VDC Power consumption 0.8 W Fuse 0.5A PTC Transient protection Yes, transil diode Reverse connect protection Yes Connector 2-pos screw terminal Indicator One green LED power on Table 2 Serial RS-232 Interface Property Description / Value Topology RS-232C interface Serial port speed 300 to baud Connector 6-pos screw terminal Indicators Two orange LEDs TxD and RxD VAISALA 19
22 User's Guide Table 3 Ethernet Interface Property Description / Value Protocols TCP/IP, UDP/IP, ARP, ICMP, SNMP, TFTP, Telnet, DHCP, BOORP, HTTP and AutoIP. Interface Ethernet 10/100Base-T (Auto-Sensing) Password protection Version 2.0/IEEE Internet Web Server Serves web pages and Java applets Storage capacity 384 Kbytes Connector RJ-45 Shielded Indicators 10Base-T, 100Base-T connection Table 4 Mechanical Property Description / Value Housing material EN AW-1050A aluminium, gray anodized Housing classification IP30 (NEMA 1) Dimensions 25x80x76mm Weight 94 g Table 5 Environmental Property Description / Value Operating temperature -40 C C Storage temperature -60 C C Humidity 5 to 95% RH, non-condensing EMC EN Immunity ESD EN , contact dis. 4kV, air dis. 8kV RF field EN Fast transient bursts (EFT) EN Transient surges EN Conducted RF EN Vibration IEC Fh, Hz, up to 2.0 G Free fall IEC Ed, fall height 1000 mm Cold IEC , -40 C 16 hours Heat IEC , +55 C 16 hours Slow change of IEC , -40 C to +55 C, two cycles temperature, 1 C/min 20 M210608EN-A
Internet-bridge XPort
Ing. Z.Královský Ing. Petr Štol Perk 457 Okrajová 1356 675 22 STA 674 01 T EBÍ Development & production of control equipment Tel.: 568 870982 Tel.: 568 848179 Visualization, measurement and regulation
More informationPRILINK PRI Management System
www.prilink.com PRILINK PRI MANAGEMENT SSTEM INSTALLATION GUIDE PRI Management PRILINK PRI Management System Installation Guide Version 3.0, Rev. 12-01-24 Page 1 Table of Contents 1 HARDWARE INSTALLATION...
More informationUPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
More informationTCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
More informationHWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
More informationBIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
More informationUser Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
More informationRS232/485 TCP/IP converter TPC2RS. Ver. 01A- GB
RS232/485 TCP/IP converter TPC2RS Ver. 01A- GB ----------- TCP2RS -------------- User s manual -------------------- page 2/43 1: INTRODUCTION...5 1.1 NETWORK PROTOCOLS...5 1.1.1 Packing Algorithms...6
More informationUSER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
More informationUDS10 UDS100 User Guide
UDS10 UDS100 User Guide Part Number 900-360 Revision A June 2004 Copyright & Trademark 2004, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any
More informationFirst Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200
Remote Access Gateway IGW/922 with DIL/NetPC ADNP/9200 First Steps SSV Embedded Systems Dünenweg 5 D-30419 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: sales@ssv-embedded.de Document
More informationENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationRS232/485 - TCP/IP converter TPC2RS. (Code M54030) INSTRUCTION MANUAL (M98122801-03-05A)
RS232/485 - TCP/IP converter TPC2RS (Code M54030) INSTRUCTION MANUAL (M98122801-03-05A) ----------------------- TCP2RS ------------------------------------------------------ User s manual--------------------------------------------------------------
More information50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW-50040. Quick Installation Guide
50-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-50040 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements... 5 4. Terminal
More informationProduct Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB
Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject
More informationSecure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by
More informationUser Manual Revision 2.003 English
Document code: MN67120_ENG Revision 2.003 Page 1 of 15 User Manual Revision 2.003 English RS232 / RS485 / Ethernet - Converter (Order Code: HD67120) for Website information: www.adfweb.com?product=hd67120
More informationTRP-C31M MODBUS TCP to RTU/ASCII Gateway
TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
More informationHow To Run An Nport I5000A Device Server
NPort IA5000A Series 1, 2, and 4-port serial device servers for industrial automation Enhanced surge protection for serial, LAN, and power 2 KV isolation for serial signals Rugged screw-type terminal blocks
More informationConfiguring the Switch with the CLI-Based Setup Program
APPENDIX D Configuring the Switch with the CLI-Based Setup Program This appendix provides a command-line interface (CLI)-based setup procedure for a standalone switch. For product overview information,
More informationLS-101 LAN to Serial Device server. User s Manual
LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial
More informationCNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program
CNC File Transfer Box The CNC File Transfer connects a serial CNC device to the network so files can be easily transferred from a computer to the CNC equipment. Any computer on the network can transfer
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationIndustrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
More informationUDS2100 Quick Start Guide
Quick Start Guide 2008 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-447 Rev. B 7/08 QUICK START CONTENTS What s In the Box..........................................................2
More informationMAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0
MAX T1/E1 TM VoIP Gateway Quick Start Guide Version 1.0 Contents INTRODUCTION 1 Hardware Needed Software Needed 1 1 NET2PHONE MAX SET UP Hardware Set Up Software Set Up Set Up Internet Protocol (IP) Address
More informationRN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationUDS1100 User Guide Part Number 900-417 Revision B June 2006
UDS1100 User Guide Part Number 900-417 Revision B June 2006 Copyright & Trademark Contacts 2006, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in
More informationApplication. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
More informationTroubleshooting 920i / iqube Email Issues
TM UNITS PRINT Troubleshooting 920i / iqube Email Issues If you are having trouble connecting to your networked 920i, the problem might be caused by IP addressing or network firewall issues. First, see
More informationManual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
More informationOne Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationEtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information
London Electronics Limited Warren Court, Chicksands, Shefford, Bedfordshire SG17 5QB Tel +44(0)1462-850967 Fax +44(0)1462-850968 www.london-electronics.com help@london-electronics.com Ethernet to RS232
More informationORION TELECOM NETWORKS INC. T1
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240,
More informationNAFEM Gateway User s Manual For Watlow part numbers NGW0-0000-0000, NGW0-0000-2400, NGWC-0000-0000, NGWC-0000-2400
NAFEM Gateway User s Manual For Watlow part numbers NGW0-0000-0000, NGW0-0000-2400, NGWC-0000-0000, NGWC-0000-2400 1241 Bundy Boulevard, P.O. Box 5580, Winona, Minnesota USA 55987-5580 Phone: +1 (507)
More informationCommunication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
More informationSetup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
More informationUser Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
More information1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
More informationxdirect User Guide Part Number 900-653-R Revision A September 2012
xdirect User Guide Part Number 900-653-R Revision A September 2012 Copyright & Trademark Warranty Contacts Disclaimer 2012 Lantronix, Inc. All rights reserved. No part of the contents of this book may
More informationRouter Setup Manual. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17
NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10060-01 2006-03-17 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear, Inc. Microsoft, Windows,
More informationEMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
More informationTK700 +70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router
+70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W The industrial 2G GPRS- and 3G UMTS routers offered by Welotec enables the access to Ethernet devices or a local network remotely via mobile network
More informationxpico User Guide Part Number 900-618 Revision A April 2012
xpico User Guide Part Number 900-618 Revision A April 2012 Copyright and Trademark 2012 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form
More informationInstallation Manual Premier Elite ComIP
Installation Manual Premier Elite ComIP INS273-5 Overview Introduction The ComIP module allows the Premier & Premier Elite control panels to be connected to either a Local Area Network (LAN) or Wide Area
More informationPowerware Environmental Rack Monitor User s Guide
Powerware Environmental Rack Monitor User s Guide FCC Part 15 Class B EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationSerial over Ethernet Device Server. User s Manual
Serial over Ethernet Device Server User s Manual Second Edition, November 2005 SUNIX Co., Ltd. Tel : +886-2-8913-1987 Fax: +886-2-8913-1986 Http://www.sunix.com.tw info@sunix.com.tw Serial over Ethernet
More informationQuick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3
Quick Setup Guide Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3 DPS1000 Series is a data protection solution that enables Internet Small Computer System Interface (iscsi) desktop
More informationWireless Router Setup Manual
Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,
More informationHomeWorks P5 Processor Ethernet TCP / IP Networking Specification
HomeWorks P5 Processor Ethernet TCP / IP Networking Specification Table of Contents Table of Contents...2 Revision History...2 Overview...3 Single Ethernet Port...3 Protocols Used...3 TCP / IP Settings...3
More informationINTRODUCTION FEATURES OF THE ICM
INTRODUCTION The ICM, Internet Control Module, is a remote controller device accessible via the Internet that allows operational access to the IPS (and other base units available). Through the ICM you
More informationTK800-Series Industrial GPRS / UMTS / LTE Router
The new generation LTE with 100 Mbps LTE standard for high transmission rates and good network coverage in sparsely populated areas Dynamic Multipoint VPN GRE, L2TP, IPSec, DMVPN, OpenVPN Simple and fast
More informationNetwork Interface Panel User s Guide NPD4747-01 EN
User s Guide NPD4747-01 EN Contents Contents Copyright and Trademarks Safety Instructions Important Safety Instructions... 4 Cautions and Notes... 4 Getting to Know Your Network Interface Panel Package
More informationETHERNET WEATHER STATION CONNECTIONS Application Note 33
ETHERNET WEATHER STATION CONNECTIONS Application Note 33 With WeatherLink and a Device Server INTRODUCTION It is possible to substitute an Ethernet connection for the direct USB or serial connection that
More informationHardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200
Linux Device Server IGW/922 with DIL/NetPC ADNP/9200 Hardware Reference SSV Embedded Systems Heisterbergallee 72 D-30453 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: sales@ist1.de
More informationXPort Device Server User Guide
XPort Device Server User Guide Part Number 900-270 Revision P November 2014 Intellectual Property 2014 Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced
More informationIn-Sight Hardware specifications
specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited
More informationRecommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install
TPDIN-Monitor-WEB Web Based Monitor and Control Remote Power Stations Backup Power Systems Solar Systems Wind Powered Systems Industrial Sense & Control Process Automation Congratulations! on your purchase
More informationEIB/KNX IP Interface with Power over Ethernet (PoE)
EIB/KNX IP Interface with Power over Ethernet (PoE) IP Interface between LAN and EIB/KNX bus (Quelle: EIBMARKT GmbH, Reference No.: N000401) Page 1 Application area The KNXnet/IP-Interface is used to connect
More informationMODBUS TCP to RTU/ASCII Gateway. User s Manual
MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...
More informationJDSU PathTrak. HCU200 Install User s Guide
JDSU PathTrak HCU200 Install User s Guide Notice Copyright System Requirements The information contained in this document is the sole property of JDSU and may not be reproduced, copied, or communicated
More informationLevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationSMAC SM Status Monitoring and Control Quality of Service (QoS) Diplex Switch Test Gear. Installation & Operation Manual
SM by Status Monitoring And Control Solutions (HMS Compliant, SNMP Based) SMAC SM Status Monitoring and Control Quality of Service (QoS) Diplex Switch Test Gear Installation & Operation Manual Although
More informationABB i-bus KNX IP Router IPR/S 2.1
Product Manual ABB i-bus KNX IP Router IPR/S 2.1 Intelligent Installation Systems This manual describes the function of the IP Router IPR/S 2.1 with the application program IP Routing. Subject to changes
More informationSNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
More informationUser Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)
User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP) UMPCEA Rev 1.0, 05/2007 COPYRIGHT NOTICE This manual is a publication of Brainchild Electronics Co... Ltd.
More informationEZ-View Network Communications Guide www.cszindustrial.com
Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241
More informationBroadband Router ESG-103. User s Guide
Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits
More information2012 uptimedevices.com
2012 uptimedevices.com Contents Product Overview...3 Installation...4 Web Interface Orientation...5 Web Interface (Login Screen)...6 Summary Screen...7 Sensors Screen...8 Sensor Names...9 Graph...10 Alerts
More informationIntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
More informationNetwork Management Card
Network Management Card Installation manual IP= MAC=00E0D8FF855E Reset 100 10 data Card Settings 1 2 RS232 Download ETHERNET RS232 66074 34003641EN/AG - Page 1 1 2 1 2 Quick start ASI or STS U-Talk ASI
More informationNetBiter webscada Modbus User Manual
User Manual IntelliCom Innovation AB Pilefeltsgatan 93-95 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision List Revision Date
More informationdedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information
More informationJob Aid Pre-Installation Information S8500 Media Server
Required information Job Aid Pre-Installation Information S8500 Media Server This job aid provides the information, hardware requirements, and computer hardware and software specifications necessary for
More informationModel 2120 Single Port RS-232 Terminal Server Frequently Asked Questions
Applications What are some of the applications for the Model 2120 Single Port Terminal Server? The Patton Single Port RS-232 Terminal Server provides the ability to bring virtually any RS-232 device onto
More informationDCB Ethernet Tunnel Family Configuration Guide
DCB Ethernet Tunnel Family Configuration Guide Introduction Thank you for your purchase of the DCB Ethernet Tunnel. This guide will step you through a typical installation as shown in the following diagram.
More informationNetwork Management Card
Network Management Card AP9617 AP9618 AP9619 Installation and Quick-Start Manual How to Avoid Equipment Damage Disconnect UPS power You do not need to turn off a Symmetra or a Silcon model UPS to install
More informationILPH technical documentation Ethernet - serial interface e-ilph
ILPH technical documentation Ethernet - serial interface ABB Page 1 1SNB 002323 R2100 V1.1 1. Description... 3 2. Connection... 3 2.1. Power supply... 3 2.2. Ethernet Network... 4 2.3. Serial port... 4
More informationEnergy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
More informationUSER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
More informationDMX2PWM 9 Channel Dimmer Setup Manual
DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4
More informationOUTDOOR IR NETWORK CAMERA Series
OUTDOOR IR NETWORK CAMERA Series INSTALLATION GUIDE Please read instructions thoroughly before operation and retain it for future reference. 1. OVERVIEW 1.1 Package Content Network camera Installation
More informationUniversal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
More informationMODBUS TCP to RTU/ASCII Gateway
MODBUS TCP to RTU/ASCII Gateway Users Manual Model MODport-101, MODport-102, MODport-104 July 2011 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING
More informationChapter 1 Installing the Gateway
Chapter 1 Installing the Gateway This chapter describes how to set up the wireless voice gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration. For information
More informationUSB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address
More informationT3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
More informationRS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual
RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
More informationIndustrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide
Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch IGS-5225 Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5 4. Terminal
More informationSerial Over IP Ethernet Device Server
NETRS2321E NETRS2321EEU NETRS2321EGB Instruction Manual Serial Over IP Ethernet Device Server 1 Port RS-232/422/485 Serial over IP Ethernet Device Server Manual Revision:10/13/2010 For the most up-to-date
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationUser Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 1.6 Page 1 Publication Revision No. Control Table Rev. No. Date Contents 1.6 8/22/07 Support connection of multiple WM5.0 devices 1.5 6/18/07 Support
More informationNetworking Alpha signs on a TCP/IP network
Networking Alpha signs on a TCP/IP network Contents Introduction................. 2 Why use serial servers?........... 2 Types of serial servers available..... 3 Valid Adaptive signs for an Alpha Ethernet
More informationNetwork Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
More informationWelcome. Unleash Your Phone
User Manual Welcome Unleash Your Phone For assistance with installation or troubleshooting common problems, please refer to this User Manual or Quick Installation Guide. Please visit www.vonage.com/vta
More informationAXIS 205 Network Camera Quick Installation Guide
AXIS 205 Quick Installation Guide Page 1 of 6 AXIS 205 Network Camera Quick Installation Guide Focus Ring Status Indicator (surrounding the focus ring) Serial number Network Indicator Control Button Power
More information