1 TPDIN-Monitor-WEB Web Based Monitor and Control Remote Power Stations Backup Power Systems Solar Systems Wind Powered Systems Industrial Sense & Control Process Automation Congratulations! on your purchase of the TPDIN-Monitor- WEB PowerSens System Monitor. Please take a moment to review this Qwik Install Guide before installation. Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail Qwik Install STEP 0: The TPDIN-Monitor-WEB can be used to monitor Qty 4 1V- 80V Voltages, 4 Currents ( Qty 2 +/- 10A and Qty 2 +20A) and two temperatures (1 internal and 1 external). There are 4 10A relays that can be used to control power to 4 devices. Two of those relays can be automatically set based on a temperature or voltage value. Two can be operated automatically based on a ping watchdog or time control. STEP 1: Install the TPDIN-Monitor-WEB to a suitable DIN rail mount. STEP 2: Connect the voltages to be monitored to the V1 V4 voltage ports. The green connector needs to be removed to be able to access the wire terminal screws. The green connectors are numbered 1-7 and should be re-installed back in their proper position. Voltages between 1 and 80volts DC can be monitored. STEP 3: Connect the currents to be monitored to the I1-I4 current ports. I1 and I2 can read currents from 0.1 to 20A. I3 and I4 can read positive or negative currents to +/-10A. These can be used to measure current flowing into and out of a battery to see if the battery is charging or discharging. The green connectors may need to be removed to be able to access the wire terminal screws. The green connectors are numbered 1-7 and should be re-installed back in their proper position.
2 STEP 4: Connect any power to devices you want to be under relay control to the CHI CH4 relays. The relays are normally closed relays so activating the relay will open the relay. STEP 5: Connect the External Temperature sensor to the included green wire terminal connector. Connect the wires to IN and IN+ terminals. Plug the wire terminal connector to the Temp. connector location. Locate the external temperature sensor where you want to measure external temperatures. You can extend the wire lengths if desired by soldering additional wires to the existing wires. You can measure temperatures from 40C to +125C STEP 6: The TPDIN-Monitor-WEB can be powered with 10-58VDC thru wire terminal connector #7 or via 802.3af or Passive 48V POE thru the RJ45 POE/DATA port. STEP 7: Download the Discovery Tool from Support/support_TPDIN-Monitor-WEB.htm. The TPDIN-Monitor-WEB ships with IP addressing by DHCP enabled. The discovery tool will find the IP address of the device so you can access the web control panel. If not connected to a DHCP server the default IP address is STEP 8: Open the Web control panel of the unit by using the discovery tool or typing the units known IP address into a browser. The unit will serve up the Monitor web page. The monitor page is where all the voltage, current, temperature and relay status can be seen. Relays can also be controlled manually from this page. There is a cycle button by the relays if you want to automatically cycle a relay from on to off and back. The cycle delay is specified on the SYSTEM page. STEP 9: Open the Network Page. Here you can set a static IP Address. You can also set access security by entering a user name and password (10 characters max). You can also set a unique Host Name to identify the Monitor. 2
3 STEP 10: Open the System Page. You should add meaningful labels to all the Voltages, Currents, Relays and Temperatures that you are using. You can also change various settings on this page. Relays: Relays are normally closed to save power when on. If you want them to be initially open at power-up, check the box that says Initial Off. Cycle Delay: This controls how long the relay stays in the opposite state when cycle is clicked on the Monitor Screen. Voltage, Current and Temp Offsets: You can enter + or offset values if you want to calibrate the TPDIN-Monitor-WEB to match another piece of measurement equipment or compensate for cable losses. Log Interval: This sets the number of seconds between log readings. The log can store 1300 data sets. If this is exceeded the oldest records will be discarded as new records are entered. Note: If set to 0 the logging of data is disabled and the graphs and some other functions won t work. Time: There is no real time clock so if the device loses power the clock will reset. Enable NTP to get the time automatically from the internet. Set GMT for your time zone. Or you can sync the clock manually to your PC Time by disabling NTP. 3
4 STEP 11: Open the Control Page. This is where you can set the relay Ping Control or Time and Temperature or voltage controls. You can set up the server and set various triggers. Relays 1 and 2: Time Control: Set the On time and Off time in 24hr format. Note: Time control overrides Ping Control and Manual control. Ping Control: Set the IP Address to ping. Set the ping frequency (Every). Setting the frequency to zero disables the ping. Set the number of consecutive Fails before the relay will cycle. Set the Wait so that the system will wait before pinging again. This is useful to allow the unit that you are pinging to fully reboot after a power cycle. Example: if you set the unit to ping every 60 seconds and you have fail set to 2, it will take approx. 2 minutes before it would see two consecutive failures and then cycle the relay. Relays 3 and 4: Temperature Control: Relay 3 can be controlled by the Internal Temperature and Relay 4 can be controlled by the External temperature probe. Make sure ON temperature is lower than OFF temperature setting. Typical Application: Fan Control: Set ON to 50; Set OFF to 100 Heater Control: Set ON to 40; Set OFF to 20 Voltage Control: Set the relay turn on and turn off voltages. Relay 4
5 will change state when voltage goes outside the range. Temperature set takes priority. Alerts: Set the server: ie; smtp.1and1.com Note: GMAIL accounts won t work because they require SSL security when sending s. Set the account user name and password. Leave user name blank to force no authentication. Password field is 10 characters max. Check the Use Username as From Field checkbox (recommended) to have the s sent from the username which is usually an address. If not checked, the s will be sent from the address entered in the first MAIL To: field. Enter the destination addresses in the Mail To: fields. They can be the same or different depending on your needs. Select the parameter trigger from the dropdown box on the left. Periodical: This will send an of the present readings periodically based on the number of minutes entered into the Lower/minutes box. Caution: if you leave set at 0 it will send an every two seconds Relay 1-4: These will send an any time the state of the relay changes due to some automatic relay control like Ping, Time or Temperature. It won t send an when the relay is manually operated. Relay 1-4 doesn t require any lower or upper settings. Leave at 0. Volt Amp and Temp: Just set Lower and Upper values and the system will send an anytime the reading is outside the set range. The frequency of s is set by the Analog Values Mail Delay time. If the delay time is set too low you will receive a flood of s whenever one of your set parameters fall outside the set range. TECH CORNER Additional Information you may find useful 1. FUSE: The TPDIN-Monitor-WEB has an internal 2A fuse. If the TPDIN-Monitor-WEB doesn t power up, check the fuse. 2. LIMITS: Don t exceed 80V on the voltage inputs or 20A on the current inputs or 10A on the relays or the unit could be damaged. This kind of damage isn t covered under warranty. 3. MOISTURE: The TPDIN-Monitor-WEB is designed to be used indoors or outdoors in a weatherproof enclosure. Avoid getting the TPDIN-Monitor-WEB wet. This kind of damage isn t covered under warranty. 4. BATTERY STATUS: If measuring voltage of battery systems 5
6 typical state of charge readings are as follows. These readings are without any load on the battery. For max battery life don t discharge under 50%: State Of Charge Sealed or Flooded Lead Acid GEL Battery AGM Battery 100% 12.7+Volts 12.9+Volts 12.8+Volts 75% 12.4 Volts 12.7 Volts 12.6 Volts 50% 12.2 Volts 12.4 Volts 12.3 Volts 25% 12.0 Volts 12.0 Volts 12.0 Volts 10% 11.8 Volts 11.8 Volts 11.8 Volts 5. Operating Power: The TPDIN-Monitor-WEB has extremely low operating power, typically less than 3W. The relays are normally closed type so in typical operation they don t take any power until they are energized. If the relays are turned on to hold them open, the power usage will increase. Specifications Voltage Meas (DC) V1, V2, V3, V4 = 1-80VDC Voltage Meas Accuracy +/- 0.1V Current Meas (DC) I1, I2 = 0.1A to 20A I3, I4 = +/-10A Current Meas Accuracy +/- 0.1A Temperature Meas T1,T2 = -40C to 125C Temp Meas Type T1 = Embedded, T2 = External Sensor (included) Temp Meas Accuracy +/- 1 degc Relays (Normally Closed Type) R1, R2, R3, R4 = 10A DC Relay Control R1, R2 = Manual or Ping or Time Control R3, R4 = Manual or Temperature Control 10-58VDC Wire Terminal or 802.3af Class 0 POE, Power Requirements 3W Typ Accessibility Via Web Browser and SNMP Data-Logger FIFO, Max 1300 data sets, Program log interval Connections Removable Wire Terminal Wire Size 12AWG Max Mounting DIN Rail Operating Temperature -40C to +75C (-40F to 167F) Humidity (RH) 0% - 90% Dimensions (LxWxH) 125 x 102 x 46mm (4.9 x 4 x 1.8 ) Weight 410g (14.5 oz) 6
7 6. SNMP: The TPDIN-Monitor-WEB can be controlled via SNMP for automated operation. Setup the SNMP on the SNMP page in the web interface. The unit will respond to SNMP queries to gather data and control relays from a script running on a remote computer. The unit doesn t allow setting of local SNMP traps. 7. WIRE TYPE: When using the monitor in high current applications (>10A), it s important to use a stranded wire with many fine strands. This type of wire will provide a low resistance electrical connection to the green connectors. If using course strand wire such as THHN, there will be higher resistance in the connection which will generate excessive heat at high currents, possibly causing damage to the connectors. NEC Wire Class C and D are acceptable. Connector Pinouts 7
8 Limited Warranty The TPDIN-Monitor-WEB products are supplied with a limited 24 month warranty which covers material and workmanship defects. This warranty does not cover the following: Parts requiring replacement due to improper installation, misuse, poor site conditions, faulty power, etc. Lightning or weather damage. Physical damage to the external & internal parts. Products that have been altered, or defaced. Products that have been subjected to voltages or currents greater than the published ratings. Water damage for units that were not mounted according to user manual. Usage other than in accordance with instructions and the normal intended use. Typical Application Rev 6 TPDIN-Monitor-WEB Qwik Install Guide 8
Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input
Temperature Alert. LAN-based Temperature and Humidity Data Logger
Temperature Alert LAN-based Temperature and Humidity Data Logger LAN-based Temperature and Humidity Monitoring - Supports Simultaneous WiFi and Hardwired Interfaces -20 C to +60 C (-4 F to +140 F) Standard
A-Series Data Loggers PRODUCT MANUAL
A-Series Data Loggers PRODUCT MANUAL Model # s A110, A125, A130, and A150 Contents Model Specifications 2 Connecting to the Computer 3 SpecWare Software 4 Installation and Placement 6 Battery Replacement
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
SNMP Web Management. User s Manual For SNMP Web Card/Box
SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com
Users manual. TCW181B-CM_R1 Page 1
Ethernet controller TCW181B-CM Users manual 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs.
IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network
IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This
USB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
USB Edition TM-STD30 User Guide
USB Edition TM-STD30 User Guide 1 Rev 4.0.8 http://www.temperaturealert.com/ 2012 Temperature@lert User Guide Thank you for choosing Temperature@lert. The USB Edition monitors the ambient temperature and
SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions
ETHERNET IRRIGATION CONTROLLER Irrigation Caddy Model: ICEthS1 User Manual and Installation Instructions I R R I G A T I O N C A D D Y M O D E L : I C E T H S 1 User Manual and Installation Instructions
SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES
SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES www.unipowerco.com 2014 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive, Coral Springs,
Olson Electronics Remote Power Monitoring Meter
Olson Electronics Remote Power Monitoring Meter Operation Guide Key Features Amps: 00.00 to 32.00A True RMS (rated short period to 40A) Volts: 200.0 to 250.0V True RMS Watts: 0000 to 9999W KWh: 000000.0
SDI Multi Sensor Module with Charger Enclosure Station Support
Description The purpose of the is to provide a low power temperature compensated battery charge controller and a general-purpose interface for analog sensors. Sensor and charge controller data are acquired
GPS NTP Time Server for Intranet Networks DIN RAIL Version
GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
Gigabyte Content Management System Console User s Guide. Version: 0.1
Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...
Quick Installation Guide
V48.01 Model: FI8919W Quick Installation Guide Outdoor Pan/Tilt Wireless IP Camera For Windows OS ------- Page 1 For MAC OS ------- Page 15 ShenZhen Foscam Intelligent Technology Co., Ltd Quick Installation
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Solar Controller / Battery Charger User s Manual
Solar Controller / Battery Charger User s Manual 1 Congratulations! You have made an excellent choice by purchasing this high quality KORR PWM solar controller which has been manufactured to the highest
Intelligent power sockets IQsocket tm IQSB-PicoIP. makes your life more comfortable. User guide. IQSB-PicoIP documentation v1.0 R1
Intelligent power sockets IQsocket tm IQSB-PicoIP makes your life more comfortable User Guide IQSB-PicoIP documentation v1.0 R1 User guide www.iqsocket.eu Important information... 2 1 Introduction... 4
IN5100 Series Networking Guide
IN5100 Series Networking Guide This guide is only intended to explain Network Functions. For safety, operations or any other issues, refer to the projector s User s Guide or Safety Booklet. TABLE OF CONTENTS
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I-00453 Rev B
User s Manual UPS SERIES Network Interface Card UPS-IPCARD I-00453 Rev B TABLE OF CONTENTS INTRODUCTION............................................................. 3-4 INSTALLATION GUIDE.......................................................
User s Manual Network Management Card
User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction
2012 uptimedevices.com
2012 uptimedevices.com Contents Product Overview...3 Installation...4 Web Interface Orientation...5 Web Interface (Login Screen)...6 Summary Screen...7 Sensors Screen...8 Sensor Names...9 Graph...10 Alerts
VIDI + Product description. System Controller for OPUS DC Power Systems. VIDI+ System Controller. Features
1 VIDI + System Controller for OPUS DC Power Systems Product description VIDI is the advanced monitoring and control device for OPUS DC Power Systems. It delivers intelligence, an easy user interface and
Instruction Manual Environmental Monitoring Unit. Watchdog 1000 Series Firmware Version 3
Instruction Manual Environmental Monitoring Unit Watchdog 1000 Series Firmware Version 3 Geist. 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistglobal.com Contents
Quick Installation Guide
V2.01 Model: FI9821W Quick Installation Guide Indoor HD Pan/Tilt Wireless IP Camera Black White For Windows OS ------- Page 1 For MAC OS ------- Page 16 ShenZhen Foscam Intelligent Technology Co., Ltd
Smart Energy Control for Building Management & Production Plant
Multipoint Temperature SMS NET Data Logger GSMS NET HV Smart Energy Control for Building Management & Production Plant Max. 8 digital temperature sensors Data communication via SMS and Ethernet Integra
ThermIT: Setting up Alarms
ThermIT: Setting up Alarms Contents Introduction... 2 Alarm Types... 2 Main Module Alarms:... 2 Linked Sensor Alarms... 2 Temperature Alarms:... 3 How to find the alarm page... 3 Alarm overview... 4 Main
AGS. Owner's Manual. Xantrex Automatic Generator Start Control System
AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5
Data Capture 2014 Installation and User Manual.
Microtechnologies, Inc. 123 Whiting Street, Unit 1A Plainville, CT 06062 888-248-7103 (voice) 860-516-1549 (fax) www.temperatureguard.com Data Capture 2014 Installation and User Manual. Part 1, Installation.
Expert Power Control NET 4x 8212 / 8213
2010 Gude Analog- und Digitalsysteme GmbH 2010 Gude Analog- und Digitalsysteme GmbH 23.08.2010 Content 3 Table of content Kapitel 1 Security Advise 5 Kapitel 2 Description 5 Kapitel 3 Hardware 6 3.1 Content
Temperature & Environment Monitoring... Made Easy!
Temperature & Environment Monitoring... Made Easy! Phone 401.628.1600 Fax 401.628.1601 Web AVTECH.com User s Guide & Reference Manual AVT-150401.06 Protect Your Facility... Don t Wait Until It s Too Late!
Aeroqual Connect and Cloud
Aeroqual Connect and Cloud Page 1 Contents 1. Introduction to Aeroqual Connect and Cloud... 3 1.2. Aeroqual Connect... 3 1.3. Aeroqual Cloud... 3 2. How to Connect... 4 2.1. Aeroqual Connect... 4 2.1.1.
ebridge100spr - EoC Receiver ebridge4spt - 4 Port PoE/PoE+ EoC Transceiver Switch
PLUS Installation Guide ebridge100spr - EoC Receiver - 4 Port PoE/PoE+ EoC Transceiver Switch I.T.E. 43KC Rev. 072313 Overview: The ebridge4sk kit consists of ebridge100spr and which are Coax to CAT-5
Instruction Manual Environmental Monitoring Unit. RSMINI-P, RSMICRO, RSMINI163 Firmware Version 3
Instruction Manual Environmental Monitoring Unit RSMINI-P, RSMICRO, RSMINI163 Firmware Version 3 GM1093.doc 1 Revision Date: 10/15/2010 Contents Specifications...3 Overview 3 Environmental 3 Electrical
Installation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
WAM Remote Wireless Asset Monitoring. Website User Guide
WAM Remote Wireless Asset Monitoring Website User Guide Table of Contents Overview... 2 Login Page... 2 Quick Start Guide...3-4 Locations Page... 5 Devices Page... 5 Register Devices Page... 6 Temp or
PowerPanel Business Edition USER MANUAL
USER MANUAL Rev. 0.9 2007/10/26 Copyright 2006-2007 Cyber Power Systems, Inc. All rights reserved. PowerPanel Business Edition USER S MANUAL PowerPanel Business Edition provides power management Services.
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
Instruction Manual Environmental Monitoring Unit. Watchdog 1200 Series Firmware Version 3
Instruction Manual Environmental Monitoring Unit Watchdog 1200 Series Firmware Version 3 GM1089 - Watchdog 1200 Series User Manual 1 Revision Date: 02/13/2015 Contents Contents... 2 Specifications... 3
Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC
Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC BAYweb Remote Model BW-BCU5 Owner's Manual Copyright 2009-2010 Bay Controls, LLC Part Number: BW-BCU5DOC Revision: 0.2 April 18, 2010 BAYweb is a
Innovative Electronics for a Changing World INDEX
Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.
VoIP Zone Controller: 4-Port Audio Out Operations Guide
The IP Endpoint Company VoIP Zone Controller: 4-Port Audio Out Operations Guide SiP Compliant 010881 Document Part #930109D for Firmware Version 1.0.6 CyberData Corporation 3 Justin Court Monterey, CA
Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface
Advanced Power over Ethernet Controllers Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER Gigabit PoE Ports Intuitive Configuration Interface Advanced Switch Management Features Advanced Gigabit PoE Managed Switch
Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7
Contents Introduction--1 Product Description.................................. 1 Internal Management Features........................... 3 Front Panel........................................ 5 Watchdog
LAN CONTROLLER instruction from 2.30
LAN CONTROLLER instruction from 2.30 RESTARTER, MONITOR, WATCHDOG, CONTROLLER FEATURES: WWW or SNMP v2 management. firmware upgrade via TFTP read data in real time without refresh page read all sensors
Product Guide CM-Relay
Product Guide CM-Relay www.theclimate.co.uk tel: 01491 410913 The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL. Overview CM-Relay combines climate monitoring with remote relay
Charge Regulator SCR 12 Marine
Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for
Sensatronics Senturion Environmental Monitor Operations Manual
Sensatronics Senturion Environmental Monitor Operations Manual Farrall Hall Annex installation Developed by: Zach Andrews Eric Barr Brandon White 1 Opening disclaimer: This is not the official manual of
USB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use
Standard Shipping Contents of the TW-SSBP-007: 1 qty Site Survey Battery Pack (Diagram 1) 1 qty Charger (Diagram 2) 1 qty RJ-45 Red (802.3af) POE Cable (Diagram 3) 1 qty 2 56 Volt Power Cord (Diagram 4)
1. Installation Requirements
1. Installation Requirements 1.1. Package Contents Analog Telephone Adapter (CRA-210) Standard Telephone Cable (RJ11) Ethernet Cable (RJ45) Power Adapter 1.2. You will also need the following: 1.2.1. A
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
Ethernet controller TCW122B-CM (Firmware version 2.xx) User manual
Ethernet controller TCW122B-CM (Firmware version 2.xx) User manual 1. Short description TCW122B-CM is an Ethernet controller, based on TCW122 hardware. It has 2 digital and 2 analog inputs, 1-Wire interface
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
Light Level. Sensor. Accessory Device Connector. Serial Connector. Lamps. Temperature and Air Flow. Humidity. Sensor I/O Ports (terminals) Sensor
WeatherDuck: Serial Port Climate Monitor WxDux-1 Specification (5/4/03). IT WatchDogs, Inc. Remote PC Environment Monitor A simple, low-cost way to monitor remote computer rooms or cabinets, the WeatherDuck
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use
SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no
DVG-2101SP VoIP Telephone Adapter
This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 6.2.3. DVG-2101SP VoIP Telephone Adapter Before You Begin 1. If you purchased this VoIP Telephone
BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:
BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960 This manual covers installation and operation procedures for BNC AM members: Berkeley Nucelonics - 2955 Kerner Blvd. San Rafael, CA 94901 - (415)453-9955 -
WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
Temperature & Environment Monitoring... Made Easy!
Temperature & Environment Monitoring... Made Easy! Phone 401.628.1600 Fax 401.628.1601 Web AVTECH.com User s Guide & Reference Manual AVT-150401.06 Protect Your Facility... Don t Wait Until It s Too Late!
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)
Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
PoE Digital Clock. PoE Digital Clock Installation and User Guide
PoE Digital Clock Installation and User Guide Page1 CONTENTS Introduction 3 Technical Specifications 3 Installation Power over Ethernet cabling plan 4 Small scale installations 4 Sites with PoE enabled
1000 Series Data Loggers PRODUCT MANUAL
1000 Series Data Loggers PRODUCT MANUAL Model s 1650, 1525, 1450, 1425, 1400, 1250, 1225, 1200 CONTENTS General Overview 3 Model Specifications 4 External Sensors 5 Installation and Placement 6 Digital
2100 Series VoIP Phone
2100 Series VoIP Phone Installation and Operations Manual Made in the USA 3 Year Warranty N56 W24720 N. Corporate Circle Sussex, WI 53089 RP8500SIP 800-451-1460 262-246-4828 (fax) Ver. 4 www.rathmicrotech.com
Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw
Machine-to-Machine Management System Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw Automated Machine Control Sensor Data Collection and Analytics Plug
User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
This document is intended to make you familiar with the ServersCheck Monitoring Appliance
ServersCheck Monitoring Appliance Quick Overview This document is intended to make you familiar with the ServersCheck Monitoring Appliance Although it is possible, we highly recommend not to install other
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
User's Guide. Model W 3-in-1 Switching DC Power Supply
User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as
6.0. Getting Started Guide
6.0 Getting Started Guide Netmon Getting Started Guide 2 Contents Contents... 2 Appliance Installation... 3 IP Address Assignment (Optional)... 3 Logging In For the First Time... 5 Initial Setup... 6 License
NortechCommander Software Operating Manual MAN-00004 R6
NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned
FI8910W Quick Installation Guide. Indoor MJPEG Pan/Tilt Wireless IP Camera
Model: FI8910W Quick Installation Guide (For Windows OS) (For MAC OS please go to page 17) Indoor MJPEG Pan/Tilt Wireless IP Camera Black White Package Contents IP Camera FI8910W with IR-Cut.x 1 DC Power
NIC Controller & Web Interface
NIC Controller & Web Interface 24 x7 Installation and Technical Support 1-866-240-6614 Page 1 of 37 Version 1.1 Table of Contents 1 OVERVIEW... 3 2 INSTALLATION AND TURN-UP... 3 3 MINIMUM REQUIREMENTS...
GE Security. FHSD Monitor / Web Server user manual
GE Security FHSD Monitor / Web Server user manual version 1-0 / november 2004 http://www.geindustrial.com/ge-interlogix/emea 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start
mysensors Information to Users mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
Model: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
TENVIS Technology Co., Ltd. User Manual. For H.264 Cameras. Version 2.0.0
TENVIS Technology Co., Ltd User Manual For H.264 Cameras Version 2.0.0 Catalogue Basic Operation... 3 Hardware Installation... 3 Search Camera... 3 Get live video... 5 Camera Settings... 8 System... 8
This section will focus on basic operation of the interface including pan/tilt, video, audio, etc.
Catalogue Basic Operation... 2 For Internet Explorer... 2 For Other Non-IE Web Browsers... 5 Camera Settings... 6 System... 6 About... 6 PT Setting... 7 Backup and Restore Setup... 8 NTP Setting... 8 System
connect AcuRite Connect Software for USB-enabled 5 in 1 Weather Stations SAVE THIS MANUAL FOR FUTURE REFERENCE.
Instruction Manual AcuRite Connect Software for USB-enabled 5 in 1 Weather Stations Windows 7, Windows 8 and Windows 8.1 connect Questions? Contact Customer Support at (877) 221-1252 or visit www.acurite.com.
LDG DTS-6/6R Desktop Coaxial Switch / Remote
LDG DTS-6/6R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
Workshop 7 PC Software - Tracker
Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output