Flat Plate Dilatometer Test & TEXAM Pressuremeter Tests in Soil Investigations with Special Emphasis on Evaluating Settlements
|
|
- Shanon Rodgers
- 7 years ago
- Views:
Transcription
1 Flat Plate Dilatometer Test & TEXAM Pressuremeter Tests in Soil Investigations with Special Emphasis on Evaluating Settlements David L. Tucker, P.E., Regional Technical Expert Deep Foundations U.S. Army Corps of Engineers - Baltimore District CENAB-EN-GF David.L.Tucker@usace.army.mil
2 Conventional Standard Penetration Test (SPT)
3 Computation of Settlement - e log p curve One Dimensional Consolidation Test or Oedometer Test Procedure consists of applying series of normal loads and measuring the corresponding vertical deformations. Specimen is constrained laterally simulating 1-D consolidation ONLY in the vertical direction relating vertical stress to the vertical strain by the CONSTRAINED MODULUS (M)
4 Disturbed Sample What am I going to do with this????
5 Confined Compression Laboratory Oedometer Tests Stress-strain data from consolidation test typically plotted as Traditional stress versus strain (linear scales for both axis) to obtain 1-D constrained tangent modulus M e log p (p on semi- log) mid 1930 s (utilizing void ratio in lieu of strain) (After Lamb and Whitman, 1969)
6 Constrained Modulus (D and M) For Poissons ratio = , D = 0.85E (After Lamb and Whitman, 1969)
7 Constrained Modulus (M) from DMT The modulus (M or D) determined from the DMT is the vertical drained constrained (one-dimensional) tangent modulus at σ vo and is the same modulus as obtained by the oedometer test.
8 Flat Dilatometer Test (DMT) Developed in the 1970 s in Italy by Dr. Silvano Marchetti Introduced in the US in 1981 by Dr. John Schmertmann and Dr. David Crapps (University of Florida) ASTM standard D6635
9 Dilatometer Test Applications Settlement Prediction Sands and Clays Soil strength Parameters Undrained Shear Strength Friction Angle OCR and Preconsolidation Pressure Total unit weight of soil Coefficient of lateral earth pressure (Ko) P-y Curves for Laterally Loaded Piles Monitoring Densification (i.e. monitoring of deep compaction etc.)
10 Calibrated static deformation test Dilatometer Test Performed at 0.1 to 0.2m (4 8 inch) intervals (near-continuous) Low volumetric and shear strain induced during penetration measures significance of lateral stress and stress history Accurately measures deformation modulus, drained friction angle in sands and undrained shear strength in clays Test Repeatability Error: <10% Easy to use from drill rig, barge, but most efficient w/ direct push rig
11 Flat Dilatometer Test (DMT) (Marchetti Dilatometer)
12 Distortions due to Insertion (OK for rupture, but for deformation??) The shape of the blade causes less soil disturbance (insertion strains) than the conical shape of the SPT or CPT (1/3 less shear strain than those developed by the CPT). Because of less soil disturbance, the dilatometer results in a better measurement of the stress history of the soil and better correlations with the true in-situ conditions. (After Marchetti,2001 )
13 Video
14 Working Principle Displacement Controlled Test 1) Push Dilatometer blade to test depth (typ. 20 cm (8-inch) intervals at 2 cm/sec and measure thrust with load cell Thrust used to compute φ, ko, OCR, p c for sands ) Soil presses against membrane creating electrical contact--inflate membrane with nitrogen gas until it separates from blade 0.05mm and record pressure ( A reading) Take Off Pressure (After Marchetti, 1996) 3) Continue to inflate membrane until it moves 1.1 mm. Electrical switch will turn on and record pressure ( B reading) 4) OPTIONAL - Depressurize and record pressure when membrane in original A- position ( C reading pore water pressure)
15 Dilatometer Test Can be pushed with Cone Rig into soil with N 60 up to 40 blows for foot (w/18 tons thrust) Heavy drill rig (CME 55) with N 60 up to blows per foot (w/7.5 tons thrust) ISSUES IN DENSE and GRAVELLY SOILS Spacing of DMT from adjacent open boring shall be 25 boring diameters and 5 feet from adjacent DMT or CPT sounding.
16 Flat Plate Dilatometer Test (DMT) Load cell for thrust measurements 16
17 Flat Plate Dilatometer Test (DMT) 180-mm 60-mm dia. 96-mm 15-mm 17
18 Flat Plate Dilatometer Test (DMT)
19 Constrained Modulus (M) from DMT The constrained modulus determined from the DMT is highly reproducible. Comparisons both in terms of (1) M DMT versus M from high quality odometer test and (2) Predicted versus measured Settlements, result in accurate and dependable results Norway Clays (After Marchetti,2001 ) DEFORMATION MODULUS -- DMT DATA, M (bars) Residual Alluvial Virginia Soils (After Failezger & Bullock,2004 ) Tokyo Bay Clay DEFORMATION MODULUS -- OEDOMETER DATA, M (bars)
20 Flat Dilatometer Test (DMT) Data Reduction The A and B pressure readings are corrected for membrane stiffness and then converted using relationships established by Marchetti (1980), Schmertmann (1982) and others to obtain soil parameters AT EACH 10 TO 20-CM INTERVAL Interpretation to common soil parameters derived from INTERMEDIATE DMT PARAMETERS. Material Index I D Horizontal Stress Index K D Dilatometer Modulus E D
21 Flat Dilatometer Test (DMT) Data Reduction Intermediate DMT parameters Note the necessity in applying the correction R M to E D ; R M = f(i D, K D ). E D lacks information on stress history and lateral stress, drained versus undrained behavior.
22 Importance of Thrust Measurements for I D > 1.2 (Sands) φ Ko for sands OCR and P c for sands
23 Membrane Calibration A & B account for Membrane Stiffness at 0.05mm and 1.1mm respectively and gage zero offset Calibration outside the tabulated values indicates either membrane to be replaced or exercised. MEMBRANE SHALL BE REPLACED IF IT CAN T BE EXCERCISED TO FALL WITHIN PUBLISHED RANGE. Calibration extremely important in very soft soils.
24 Settlement Predictions DMT accurately measures the constrained deformation modulus (M or D) of the soil. DMT performed at 10 to 20 cm (8-inch) intervals (near-continuous) to create a Modulus versus depth profile for use in the settlement analysis. Because of the close test depth intervals, the increase in the applied vertical stress is accurately computed utilizing Boussinesq, Westergaard or other stress distribution method. (After Monaco,2006 )
25 Settlement Predictions Schmertmann (1986) developed the Ordinary and Special methods for computing settlements beneath structures and embankments. Special method adjusts M to the average vertical effective stress during the loading that produces the settlement. (i.e. does stress occur below or above p c or start below the p c and extends beyond the p c etc) Generally Ordinary versus Special Methods are within 10% of one another.
26 Accuracy of Settlement Prediction Accuracy of settlement computations have been demonstrated by numerous researchers from a data base of a variety of soils. Average ratio of predicted to actual settlement utilizing the DMT is 1.07 with a coefficient of variation (standard deviation/average value) of (Failmezger,2006 )
27 Example Poplar Island Soft Clays DH 626 Worst Case
28 Example Poplar Island Soft Clays DH 626 Worst Case Similar to the settlements observed in Dike near borings M- 72/73 Area
29 Example Poplar Island Soft Clays DH 629/DMT 718 S S
30 Example Poplar Island Soft Clays DMT 718 Laboratory Consolidation Test 17 (5.2 m) Slope = M = σ/ ε = 27 σ vo of 0.32 bar
31 Example Poplar Island Soft Clays DMT 718 Laboratory Consolidation Test 31 (9.5meters) Slope = M = σ/ ε = 29 σ vo of 0.57 bar
32 Example Poplar Island Soft Clays DMT 718 DMT versus Lab 17 (5.2 meters) & 31 (9.5m) Slope = M = σ/ ε = 27 σ vo of 0.32 bar 27 bar 29 bar Slope = M = σ/ ε = 29 σ vo of 0.57 bar
33 Example Poplar Island Soft Clays DMT 718
34 Example Poplar Island Soft Clays DMT 718 DMT versus UC Lab 31 (9.5meters) Su: 0.23 vs 0.36 bar Note: Sand in UC test will lower Su results & UC tests will generally yields lower values than UU test.
35 DMT CPT Comparisons feet meters
36 DMT CPT Comparisons feet meters
37 DMT CPT Comparisons feet meters
38 TEXAM Pressuremeter (PMT)
39 Texam Pressuremeter Test (PMT) 39
40 Check for leaks. Pressuremeter Calibrations Establish zero volume of the probe. Calibration for System Compressibility. Calibration for Membrane Resistance.
41 Pressuremeter Test (PMT) Developed in the 1950 s by Louis Menard at the University of Illinois. ASTM standard ASTM D 4719 utilizing. Method A Equal Pressure Increment Test (pressure increment = est. limit pressure/10) Method B Equal Volume Increment Test (volume increment =.05 to 0.1 V o ) Mono Cell probe (length/diameter ratio larger than 6). Main design applications include: Shallow Foundation Design under vertical loadings Deep foundation design under vertical and horizontal loadings (p-y analysis)
42 Video
43 Quality of Borehole The making of a Quality Borehole is the most important step. Drilling a quality pressuremeter borehole is much different from SPT sample drilling. SPT Sample Drilling keep disturbance to a minimum below the drill bit Pressuremeter Drilling Keep disturbance to a minimum along the borehole walls above the drill bit Nominal hole diameter shall not be more than 1.2 times the nominal probe diameter. Per ASTM D4719, D H = diameter of borehole D = Diameter of deflated probe
44 Quality of Borehole
45 Quality of Borehole Hole too small Greatly disturbed Hole too large
46 Typical Construction of Borehole for with an N-size probe (2.9 diameter) The hole is prepared utilizing mud rotary drilling. The top of the hole is cased with 4-inch diameter casing and the hole advanced with a 3-7/8 inch (roller bit for sands and 3 wing bit for clays) with AW rods to the depth of the top of the PMT test. The 3-7/8 inch roller bit is then removed and a 3-1/16 inch roller bit is inserted and advanced two feet to construct the hole for the PMT test. Following completion of the test, the 3-7/8 inch roller bit was reinserted and the procedure repeated at 5-foot intervals until the bottom of the hole. Note D H = 3.06 and D = 2.9, therefore 2.987<3.06<3.48 satisfying ASTM D4719
47 Test Procedure Calibration of Equipment (saturation and leaks, establish zero volume of probe (V o ), calibration for system compressibility, membrane resistance, hydrostatic pressure) PMT test (Method B) consists of placing a cylindrical probe into the ground and expanding the probe by injecting equal volume increases (say 40 cm 3 increments) of water into the probe to pressurize the soil horizontally and record corresponding pressures until limit of equipment is reached. Take readings after 30s and 1 min after volume (or pressure) increments are applied.
48 Schematic of TEXAM Mono-Cell Pressuremeter Actuator is turned forcing a known volume of water through the nylon tubing and recording the pressures via the pressure gage.
49 Corrected Pressuremeter Test Curve The Corrected pressuremeter curve is obtained by plotting the corrected pressure (p c ) versus the corrected relative increase in probe radius ( R/R o ) ( R/R o ) is a function of initial volume of probe and volume increments = ((V o +v c )/V o )) 1/2-1 The Coefficient of Earth Pressure Coefficient at rest (K o ), pressuremeter modulus (E o ), reload modulus (E R ), limit pressure (P L ) and net limit pressure (P L *) are determined from the curve.
50 PMT Parameters Coefficient of Earth Pressure at rest (K o ) σ ov = total vertical stress u o = hydrostatic pressure
51 PMT Parameters Pressuremeter Modulus (E o ) and Reload Modulus (E R ) E o = modulus calculated from the slope of the pseudoelastic portion of the corrected pressure-volume curve experiencing little to no creep. E R = modulus calculated from the unload-reload loop.
52 PMT Parameters Limit Pressure (P L ) and Net Limit Pressure(P L* ) P L = The pressure at which the probe volume reaches twice the original soil cavity volume. P L corresponds to a relative increase in probe radius ( R/R o ) L = ( R/R o ) c where ( R/R o ) c is the relative increase in probe radius corresponding to the initial size of the cavity. ( R/R o ) L may not be reached requiring extrapolation techniques to obtain P L Net Limit Pressure (P L* ) = P L - σ OH Net limit pressure is a measure of the strength of the soil
53 PMT Strength Parameters Undrained shear Strength Su: Su = 0.21P L * 0.75 (Su and P L* in tsf) Friction Angle φ : Not recommended
54 Preliminary Values/Soil Identification Preliminary Values for P L* and E o are illustrated below: General guidelines for soil identification:
55 Example Curve
56 Shallow Foundations Bearing Capacity Use k/1.2 for strip footings.
57 Shallow Foundations Settlement
58 Shallow Foundations Settlement Comparison Settlement summary for net bearing pressure = 4.0 tsf PMT Menard & Rousseau 1962 Tucker & Briaud 1986 DMT Schmertmann 1986 SPT Burland & Burbidge 1985 SPT Schmertmann Converting N 60 to E 1970, 78 SCPT Schmertmann E = 2.5qc 1970, 78 Q = 1210 T B= Q=225 T B =
59 References Roger Failmezger, P.E at Marchetti Briaud, J.-L, The Pressuremeter, Balkema/Rorredam/Brookfield, 1992 FHWA IP , The Pressuremeter Test for Highway Applications, Briaud, 1989
60 Questions??
APPENDIX A PRESSUREMETER TEST INTERPRETATION
APPENDIX A PRESSUREMETER TEST INTERPRETATION PRESSUREMETER TEST INTERPRETATION Description of test The pressuremeter test, discussed in great detail by Martin (1977), Baguelin et al. (1978), Barksdale
More informationc. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.
Design Manual Chapter 6 - Geotechnical 6B - Subsurface Exploration Program 6B-2 Testing A. General Information Several testing methods can be used to measure soil engineering properties. The advantages,
More informationSPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration
More informationSite Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions
This is an attempt to create a stand alone self learning module on site investigation. Fasten your seat belts. Sit back, relax and enjoy. 1 2 Site Investigation Some unsung heroes of Civil Engineering
More informationCone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District
Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District Recommended publications ASTM D 5778-07 Standard Test Method for Electronic Friction Cone and Piezocone
More informationModule 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives
Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives In this section you will learn the following Penetrometer Tests Standard penetration test Static cone penetration test Dynamic cone
More informationEurocode 7 - Geotechnical design - Part 2 Ground investigation and testing
Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Dr.-Ing. Bernd Schuppener, Federal Waterways Engineering
More informationDrained and Undrained Conditions. Undrained and Drained Shear Strength
Drained and Undrained Conditions Undrained and Drained Shear Strength Lecture No. October, 00 Drained condition occurs when there is no change in pore water pressure due to external loading. In a drained
More informationCEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests
PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the
More informationEquivalent CPT Method for Calculating Shallow Foundation Settlements in the Piedmont Residual Soils Based on the DMT Constrained Modulus Approach.
Equivalent CPT Method for Calculating Shallow Foundation Settlements in the Piedmont Residual Soils Based on the DMT Constrained Modulus Approach. Paul W. Mayne, PhD, P.E., Professor, Geosystems Engineering
More informationCIVL451. Soil Exploration and Characterization
CIVL451 Soil Exploration and Characterization 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally
More informationGeotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur
Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Lecture No. # 13 (Refer Slide Time: 00:18) So last class, it was
More informationINTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1
INTRODUCTION TO SOIL MODULI By Jean-Louis BRIAUD 1 The modulus of a soil is one of the most difficult soil parameters to estimate because it depends on so many factors. Therefore when one says for example:
More informationHow To Design A Foundation
The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural
More informationSoil Classification Through Penetration Tests
Pak. J. Engg. & Appl. Sci. Vol. 9, Jul., 2011 (p. 76-86) Soil Classification Through Penetration Tests A. H. Khan, A. Akbar, K. Farooq, N. M. Khan, M. Aziz and H. Mujtaba Department of Civil Engineering,
More informationINSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
More informationGeotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City
American Journal of Science and Technology 2015; 2(5): 237-242 Published online August 10, 2015 (http://www.aascit.org/journal/ajst) ISSN: 2375-3846 Geotechnic Parameters Analysis Obtained by Pencel Presuremeter
More informationFigure 2.31. CPT Equipment
Soil tests (1) In-situ test In order to sound the strength of the soils in Las Colinas Mountain, portable cone penetration tests (Japan Geotechnical Society, 1995) were performed at three points C1-C3
More informationUsing Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey
Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey Figen Orhun Onal GE, M.Sc., Site Works Manager, Zemin Etud ve Tasarım A.Ş., Istanbul, figen.orhun@zetas.com.tr
More informationWhich in-situ test should I use? A designer s guide
Roger A. Failmezger, P.E., F. ASCE, In-Situ Soil Testing, L.C., Lancaster, Virginia, email: insitusoil@prodigy.net, and Paul J. Bullock, Ph.D., P.E., M.ASCE, GRL Engineers, Inc., Gainesville, Florida,
More informationHow To Model A Shallow Foundation
Finite Element Analysis of Elastic Settlement of Spreadfootings Founded in Soil Jae H. Chung, Ph.D. Bid Bridge Software Institute t University of Florida, Gainesville, FL, USA Content 1. Background 2.
More informationStrength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT
Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT David L. Knott, P.E. and James M. Sheahan, P.E. HDR Engineering, Inc. 3 Gateway Center Pittsburgh, PA 15222-1074 Phone:
More informationKWANG SING ENGINEERING PTE LTD
KWANG SING ENGINEERING PTE LTD 1. INTRODUCTION This report represents the soil investigation works at Aljunied Road / Geylang East Central. The objective of the soil investigation is to obtain soil parameters
More informationCone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell
Cone Penetration Testing in Geotechnical Practice Tom Lunne Peter K. Robertson John J.M. Powell BLACKIE ACADEMIC & PROFESSIONAL An Imprint of Chapman & Hall London Weinheim New York Tokyo Melbourne Madras
More informationAnirudhan I.V. Geotechnical Solutions, Chennai
Anirudhan I.V. Geotechnical Solutions, Chennai Often inadequate In some cases, excess In some cases, disoriented Bad investigation Once in a while good ones Depends on one type of investigation, often
More informationEstimation of Compression Properties of Clayey Soils Salt Lake Valley, Utah
Estimation of Compression Properties of Clayey Soils Salt Lake Valley, Utah Report Prepared for the Utah Department of Transportation Research Division by Steven F. Bartlett, PhD. P.E. Assistant Professor
More informationNOTES on the CONE PENETROMETER TEST
GE 441 Advanced Engineering Geology & Geotechnics Spring 2004 Introduction NOTES on the CONE PENETROMETER TEST The standardized cone-penetrometer test (CPT) involves pushing a 1.41-inch diameter 55 o to
More informationOBSERVED vs DMT-PREDICTED SETTLEMENTS
OBSERVED vs DMT-PREDICTED SETTLEMENTS Lacasse & Lunne (1986) "Dilatometer Tests in Sand". Proc. In Situ '86 ASCE Spec. Conf. Virginia Tech, Blacksburg.. Authors report "very good agreement between DMT-predicted
More informationWashington 98102-3699, mike.bailey@hartcrowser.com
LESSONS LEARNED FROM A STONE COLUMN TEST PROGRAM IN GLACIAL DEPOSITS Barry S. Chen 1, P.E., Member, Geo-Institute and Michael J. Bailey 2, P.E., Member, Geo-Institute ABSTRACT A stone column test program
More informationTesting Procedures. Note: Please refer to Table 2 for a list of completed borings.
Testing Procedures Drilling and Sampling: Standard penetration tests (SPT) were conducted for every ten feet of boring advancement. SPT tests were conducted in accordance with ASTM D1586, using a 140 pound
More informationCHAPTER 1 INTRODUCTION
CHAPTER 1 INTRODUCTION 1.1 Introduction The design and construction of foundations require a good knowledge of the mechanical behaviour of soils and of their spatial variability. Such information can be
More informationGround improvement using the vibro-stone column technique
Ground improvement using the vibro-stone column technique A. Kosho 1 A.L.T.E.A & Geostudio 2000, Durres, Albania ABSTRACT The vibro stone columns technique is one of the most used techniques for ground
More informationINDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode
INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance
More informationAvailable In-Situ Tests
Available In-Situ Tests The following sections briefly discuss the basic details of the available in-situ tests, and some important, yet sometimes unrecognized, details. Additional information can be found
More informationGeotechnical Testing Methods II
Geotechnical Testing Methods II Ajanta Sachan Assistant Professor Civil Engineering IIT Gandhinagar FIELD TESTING 2 1 Field Test (In-situ Test) When it is difficult to obtain undisturbed samples. In case
More informationproduct manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer
HS-4210_MAN_09.08 product manual HS-4210 Digital Static Cone Penetrometer Introduction This Manual covers the measurement of bearing capacity using the Humboldt Digital Static Cone Penetrometer (DSCP).
More informationElectronic Soil Test Logging. Strategic Advantage or Unnecessary Headache?
1 Electronic Soil Test Logging Strategic Advantage or Unnecessary Headache? 2 The Plan 3 4 What is it? Digitally Recording Soil Test Data Why? 5 6 Traditional Work Flow Field Digital Entry Sample Review
More informationBy D. P. StewarP and M. F. Randolph z
T-BAR PENETRATION TESTING IN SOFT CLAY By D. P. StewarP and M. F. Randolph z ABSTRACT: A t-bar penetration test for soft clay that can be performed with existing cone penetration test (CPT) equipment is
More informationSoil Mechanics. Outline. Shear Strength of Soils. Shear Failure Soil Strength. Laboratory Shear Strength Test. Stress Path Pore Pressure Parameters
Soil Mechanics Shear Strength of Soils Chih-Ping Lin National Chiao Tung Univ. cplin@mail.nctu.edu.tw 1 Outline Shear Failure Soil Strength Mohr-Coulomb Failure Criterion Laboratory Shear Strength Test
More informationALLOWABLE LOADS ON A SINGLE PILE
C H A P T E R 5 ALLOWABLE LOADS ON A SINGLE PILE Section I. BASICS 5-1. Considerations. For safe, economical pile foundations in military construction, it is necessary to determine the allowable load capacity
More informationNumerical Simulation of CPT Tip Resistance in Layered Soil
Numerical Simulation of CPT Tip Resistance in Layered Soil M.M. Ahmadi, Assistant Professor, mmahmadi@sharif.edu Dept. of Civil Engineering, Sharif University of Technology, Tehran, Iran Abstract The paper
More informationTests and Analyses on Shear Strength Increment of Soft Soil under Embankment Fill
Tests and Analyses on Shear Strength Increment of Soft Soil under Embankment Fill Guanbao Ye Professor Key Laboratory of Geotechnical and Underground Engineering,Tongji University, Ministry of Education,
More informationUse and Application of Piezocone Penetration Testing in Presumpscot Formation
Use and Application of Piezocone Penetration Testing in Presumpscot Formation Craig W. Coolidge, P.E. Summit Geoengineering Services, Rockland, Maine ABSTRACT: This paper examines the advantages and limitations
More informationPenetration rate effects on cone resistance measured in a calibration chamber
Penetration rate effects on cone resistance measured in a calibration chamber K. Kim Professional Service Industries, Inc, Houston, TX, USA M. Prezzi & R. Salgado Purdue University, West Lafayette, IN,
More informationA Ground Improvement Update from TerraSystems
TERRANOTES A Ground Improvement Update from TerraSystems SOIL MODULUS AFTER GROUND IMPROVEMENT Evaluation of ground improvement is accomplished using a variety of methods, from simple elevation surveys
More informationStandard Test Method for Mechanical Cone Penetration Tests of Soil 1
Designation: D 3441 98 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Test Method
More informationCaltrans Geotechnical Manual
Cone Penetration Test The cone penetration test (CPT) is an in-situ sounding that pushes an electronic penetrometer into soil and records multiple measurements continuously with depth. Compared with rotary
More information1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum
Malaysian Civil Engineering Standard Method of Measurement (MyCESMM) CLASS D: SITE INVESTIGATION WORK Measurement covered under other classes: Excavation not carried out for the purpose of soil investigation
More informationCE 366 SETTLEMENT (Problems & Solutions)
CE 366 SETTLEMENT (Problems & Solutions) P. 1) LOAD UNDER A RECTANGULAR AREA (1) Question: The footing shown in the figure below exerts a uniform pressure of 300 kn/m 2 to the soil. Determine vertical
More informationLymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load
Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load Nature of Services The company has a long history of performance of tests of piles and pile groups under a variety
More informationCHAPTER 9 FEM MODELING OF SOIL-SHEET PILE WALL INTERACTION
391 CHAPTER 9 FEM MODELING OF SOIL-SHEET PILE WALL INTERACTION 9.1 OVERVIEW OF FE SOIL-STRUCTURE INTERACTION Clough and Denby (1969) introduced Finite Element analysis into the soil-structure interaction
More informationQUESTION TO AUDIENCE
Site investigation some aspects of EN1997 Part 2 David Norbury David Norbury Limited BGA Symposium Eurocode 7 Today and Tomorrow, Cambridge, England, March 2011 QUESTION TO AUDIENCE How many of you have
More informationInstrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test. Murad Abu-Farsakh, Ph.D., P.E.
Instrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test Murad Abu-Farsakh, Ph.D., P.E. Louisiana Transportation Research Center Louisiana State University
More informationMETHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
More informationCone Penetration Test (CPT)
Cone Penetration Test (CPT) The cone penetration test, or CPT in short, is a soil testing method which will provide a great deal of high quality information. In the Cone Penetration Test (CPT), a cone
More informationConsolidation and Settlement Analysis
19 Consolidation and Settlement Analysis Patrick J. Fox Purdue University 19.1 Components of Total Settlement 19.2 Immediate Settlement 19.3 Consolidation Settlement Total Consolidation Settlement Rate
More informationGUIDELINE FOR HAND HELD SHEAR VANE TEST
GUIDELINE FOR HAND HELD SHEAR VANE TEST NZ GEOTECHNICAL SOCIETY INC August 2001 CONTENTS Page 1.0 Introduction 2 2.0 Background 2 3.0 Recommended Practice 3 4.0 Undrained Shear Strength 3 5.0 Particular
More informationPILE FOUNDATIONS FM 5-134
C H A P T E R 6 PILE FOUNDATIONS Section I. GROUP BEHAVIOR 6-1. Group action. Piles are most effective when combined in groups or clusters. Combining piles in a group complicates analysis since the characteristics
More informationStep 11 Static Load Testing
Step 11 Static Load Testing Test loading is the most definitive method of determining load capacity of a pile. Testing a pile to failure provides valuable information to the design engineer and is recommended
More informationNUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY
NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY Ilaria Giusti University of Pisa ilaria.giusti@for.unipi.it Andrew J. Whittle Massachusetts Institute of Technology ajwhittl@mit.edu Abstract This paper
More informationChapter 5 FIELD AND LABORATORY TESTING PROCEDURES
Chapter 5 FIELD AND LABORATORY TESTING PROCEDURES Final SCDOT GEOTECHNICAL DESIGN MANUAL August 2008 Table of Contents Section Page 5.1 Introduction...5-1 5.2 Sampling Procedure...5-1 5.2.1 Soil Sampling...5-1
More informationFundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS. J. David Rogers, Ph.D., P.E., R.G.
Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS J. David Rogers, Ph.D., P.E., R.G. Cone Penetration Test CPT soundings can be very effective in site characterization, especially sites with discrete
More informationSAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS
Page 1 of 9 SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS 1. GENERAL REQUIREMENTS 1. Description of Work: This work consists of furnishing all materials, equipment and
More informationModule5: Site investigation using in situ testing
Module5: Site investigation using in situ testing Topics: Introduction Penetration testing 1. Standard penetration test 2. Cone penetration test Strength and compressibility testing 1. Field vane shear
More informationENCE 4610 Foundation Analysis and Design
This image cannot currently be displayed. ENCE 4610 Foundation Analysis and Design Shallow Foundations Total and Differential Settlement Schmertmann s Method This image cannot currently be displayed. Strength
More informationSoil Mechanics SOIL STRENGTH page 1
Soil Mechanics SOIL STRENGTH page 1 Contents of this chapter : CHAPITRE 6. SOIL STRENGTH...1 6.1 PRINCIPAL PLANES AND PRINCIPAL STRESSES...1 6.2 MOHR CIRCLE...1 6.2.1 POLE METHOD OF FINDING STRESSES ON
More informationBEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD
SENRA Academic Publishers, British Columbia Vol., No. 1, pp. 27-2774, February 20 Online ISSN: 0-353; Print ISSN: 17-7 BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD
More informationDETERMINATION OF SOIL STRENGTH CHARACTERISTICS PERFORMING THE PLATE BEARING TEST
III Międzynarodowa Konferencja Naukowo-Techniczna Nowoczesne technologie w budownictwie drogowym Poznań, 8 9 września 005 3rd International Conference Modern Technologies in Highway Engineering Poznań,
More informationSTP883-EB/Nov. 1985. Subject Index
STP883-EB/Nov. 1985 Subject Index A Aas in-situ tests, 209-210 Analytical model technique, 432, 438 Andersen's procedure, 342, 345,349-351 Arabian Gulf soils, 413 ASCE conference, 41 ASTM Standards D 422:385
More informationMethod Statement FOR. Soil Investigation
Method Statement FOR Soil Investigation PREPARED BY JUNE 2010 Infratech ASTM CO., LTD. TABLE OF CONTENTS Chapter Title Page Table of Contents..1 List of Appendix... 2 List of Table... 2 List of Figures...
More informationFOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples
FOUNDATION DESIGN Proportioning elements for: Transfer of seismic forces Strength and stiffness Shallow and deep foundations Elastic and plastic analysis Foundation Design 14-1 Load Path and Transfer to
More informationNumerical Analysis of Texas Cone Penetration Test
International Journal of Applied Science and Technology Vol. 2 No. 3; March 2012 Numerical Analysis of Texas Cone Penetration Test Nutan Palla Project Engineer, Tolunay-Wong Engineers, Inc. 10710 S Sam
More informationGeotechnical Standards Eurocodes. An update
Geotechnical Standards Eurocodes. An update Professor Ltd Sussex University EUROCOE 7 (EN 1997) Part 1 published. 2004 National Annex published 2007 Part 2 published Mar 2007 National Annex published 2010
More informationDEM modelling of the dynamic penetration process on Mars as a part of the NASA InSight Mission
Proceedings of the 4th European Young Geotechnical Engineers Conference (EYGEC), Durham, UK Osman, A.S. & Toll, D.G. (Eds.) 05 ISBN 978-0-9933836-0 DEM modelling of the dynamic penetration process on Mars
More informationCharacterization of an Artificially Prepared Cohesive Soil Bed
Pak. J. Engg. & Appl. Sci. Vol. 6, Jan., 21 (p. 26-41) Characterization of an Artificially Prepared Cohesive Soil Bed Z. Rehman 1, A.Akbar 2 and B.G. Clarke 3 1 Ph.D. Student, Department of Civil Engineering,
More informationGUIDE TO CONE PENETRATION TESTING
GUIDE TO CONE PENETRATION TESTING www.greggdrilling.com Engineering Units Multiples Micro (μ) = 10-6 Milli (m) = 10-3 Kilo (k) = 10 +3 Mega (M) = 10 +6 Imperial Units SI Units Length feet (ft) meter (m)
More informationHigh Strain Dynamic Load Testing of Drilled Shafts
Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain
More informationTECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY
TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY CETANZ Technical Report TR 1 Author(s) SJ Anderson, Geotechnics Ltd Report Date First Issue May 2010 Report Revision Date September 2011
More information2009 Japan-Russia Energy and Environment Dialogue in Niigata S2-6 TANAKA ERINA
Importance of the Site Investigation for Development of Methane Hydrate Hokkaido University Hiroyuki Tanaka Civil Engineer My Background Site Investigation Soil Parameters for Design Very Soft Clay and
More informationSUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
More informationSoil behaviour type from the CPT: an update
Soil behaviour type from the CPT: an update P.K. Robertson Gregg Drilling & Testing Inc., Signal Hill, California, USA ABSTRACT: An initial application of CPT results is to evaluate soil type and soil
More informationTable of Contents 10.1 GENERAL... 10.1-1
Table of Contents Section Page 10.1 GENERAL... 10.1-1 10.1.1 Overview... 10.1-1 10.1.2 Role of Uncertainty in Property Interpretation... 10.1-1 10.1.3 Role of Drainage in Property Interpretation... 10.1-2
More informationNumerical study of rate effects in cone penetration test
Numerical study of rate effects in cone penetration test Daichao Sheng, Richard Kelly, Jubert Pineda and Lachlan Bates Australian Research Council Centre of Excellence for Geotechnical Science and Engineering,
More informationEVALUATION OF TEXAS CONE PENETROMETER TEST TO PREDICT UNDRAINED SHEAR STRENGTH OF CLAYS HARIHARAN VASUDEVAN
EVALUATION OF TEXAS CONE PENETROMETER TEST TO PREDICT UNDRAINED SHEAR STRENGTH OF CLAYS by HARIHARAN VASUDEVAN Presented to the Faculty of the Graduate School of The University of Texas at Arlington in
More informationA study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil
ISSN: 319-53 (An ISO 39: 00 Certified Organization) A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil Utpal Kumar Das Associate Professor, Department
More information1.0 INTRODUCTION 1 2.0 SCOPE OF WORK 2 3.0 EXECUTION OF FIELD WORK 2 4.0 LABORATORY TESTS 8 5.0 FINDINGS OF THE GEOTECHNICAL INVESTIGATION 9
REPORT ON GEOTECHNICAL INVESTIGATION FOR LPG MOUNDED STORAGE AT VISAKHA REFINERY, MALKAPURAM, VISAKHAPATNAM (A.P) FOR HINDUSTAN PETROLEUM CORPORATION LIMITED CONTENTS SR.NO. DESCRIPTION PAGE NO. 1.0 INTRODUCTION
More informationSHORE A DUROMETER AND ENGINEERING PROPERTIES
SHORE A DUROMETER AND ENGINEERING PROPERTIES Written by D.L. Hertz, Jr. and A.C. Farinella Presented at the Fall Technical Meeting of The New York Rubber Group Thursday, September 4, 1998 by D.L. Hertz,
More informationMeasurement of Residual Stress in Plastics
Measurement of Residual Stress in Plastics An evaluation has been made of the effectiveness of the chemical probe and hole drilling techniques to measure the residual stresses present in thermoplastic
More informationMultiple parameters with one Cone Penetration Test. by Mark Woollard
Multiple parameters with one Cone Penetration Test by Mark Woollard Subjects introduction MW introduction APB introduction CPT portfolio APB onshore CPT equipment near shore CPT equipment offshore CPT
More informationStress Strain Relationships
Stress Strain Relationships Tensile Testing One basic ingredient in the study of the mechanics of deformable bodies is the resistive properties of materials. These properties relate the stresses to the
More informationInstrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils
Instrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils Mason Ghafghazi 1, PhD, PEng. Jason DeJong 2, Professor Department of Civil and Environmental Engineering University of
More informationLABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO
LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO STANDARD IS: 2720 (Part 16) 1979. DEFINITION California bearing ratio is the ratio of force per unit area required to penetrate in to a soil mass with
More informationLiner system design for tailings impoundments and heap leach pads
Liner system design for tailings impoundments and heap leach pads John F. Lupo, Ph.D., P.E. AMEC E&E TAILINGS & MINE WASTE 08, VAIL Liner Systems Liner systems Environmental containment of process solutions
More informationGeotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples
Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples Prof. V.S.Raju (Formerly: Director, IIT Delhi & Professor and Dean, IIT Madras) Email: rajuvs_b@yahoo.com
More informationModule 5 (Lectures 17 to 19) MAT FOUNDATIONS
Module 5 (Lectures 17 to 19) MAT FOUNDATIONS Topics 17.1 INTRODUCTION Rectangular Combined Footing: Trapezoidal Combined Footings: Cantilever Footing: Mat foundation: 17.2 COMMON TYPES OF MAT FOUNDATIONS
More informationFlat Di latometer Testi ng
Flat Di latometer Testi ng Edited bv R. A. Failmezger In-Situ Soil Testing, L.C.,, Lancaster, Virginia, USA J. B. Anderson University of North Carolina at Charlotte Charlotte, North Carolina No copyright
More informationproduct manual 08.09 H-4210A PORTABLE STATIC CONE PENETROMETER
08.09 product manual H-4210A PORTABLE STATIC CONE PENETROMETER PORTABLE STATIC CONE PENETROMETER GENERAL INFORMATION The H-4210A Static Cone Penetrometer is an unparalleled device for measuring soil consistency.
More informationGUIDE TO CONE PENETRATION TESTING
GUIDE TO CONE PENETRATION TESTING www.greggdrilling.com Engineering Units Multiples Micro (μ) = 10-6 Milli (m) = 10-3 Kilo (k) = 10 +3 Mega (M) = 10 +6 Imperial Units SI Units Length feet (ft) meter (m)
More informationSoil Strength. Performance Evaluation of Constructed Facilities Fall 2004. Prof. Mesut Pervizpour Office: KH #203 Ph: x4046
ENGR-627 Performance Evaluation of Constructed Facilities, Lecture # 4 Performance Evaluation of Constructed Facilities Fall 2004 Prof. Mesut Pervizpour Office: KH #203 Ph: x4046 1 Soil Strength 2 Soil
More informationDistribution Restriction Statement Approved for public release; distribution is unlimited.
CECW-EG Engineer Manual 1110-1-1904 Department of the Army U.S. Army Corps of Engineers Washington, DC 20314-1000 Engineering and Design SETTLEMENT ANALYSIS EM 1110-1-1904 30 September 1990 Distribution
More information